Smart-Sync Digital Clock/Timer Install GuideOneVue Synchronized Time SolutionCopyright © 2016 by Bluetooth SIG, Inc. The Bluetooth word mark and logos are owned by Bluetooth SIG, Inc. Otherthird-party brands and names are the property of their respective owners.OneVue is a trademark of Primex. The innovative technology software solution for facility and time synchronizationmonitoring and reporting. All other trademarks are the property of their respective owners. ©2016 Primex. The Primexlogo is a registered trademark of Primex. All Rights Reserved. Last update 1/4/2017
Legal NoticeCopyright ©2016 Primex. All rights reserved.Printed in the USA.Information in this document is subject to change without notice. The software described in this document isfurnished under a license agreement or nondisclosure agreement. The software may be used or copied only inaccordance with the terms of those agreements. No part of this publication may be reproduced, stored in aretrieval system, or transmitted in any form or by any means, electronic, mechanical or otherwise, for anypurpose, without the prior written permission of Primex.Worldwide Headquarters965 Wells StreetLake Geneva, WI 53147Phone: (855) 557-0337Hours: 7:00 am - 5:00 pm CSTinfo@primexinc.com
About this GuideAudienceThis guide is intended for users tasked with installing Smart-Sync Digital Clock/Timer for use with the PrimexOneVue Synchronized Timesolution.Content messagingThis guide includes notes, cautions, and warnings content that highlights important messages.Typeface IndicatesNote Indicates something important or useful.Caution Indicates a command or procedure may have an unwanted or undesirable result.Warning Indicates a command or procedure that could be dangerous to system or device.Example Provides an example of the topic.
CONTENTSSpecifications - Smart-Sync Digital Clock/Timer 8Installation and Operation Overview - Smart-Sync Digital Clock/Timer 10Installation Requirements - Smart-Sync Digital Clock/Timer 11Warranty 12Technical Support 13
Regulatory ApprovalsFCC CompliancePursuant to FCC 15.21 of the FCC rules, changes not expressly approved by Primex might cause harmful interference and void theFCC authorization to operate this product.FCC Radio Frequency InterferenceThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCCRules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with theinstructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can bedetermined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures:lReorient or relocate the receiver’s antenna.lIncrease the distance between the equipment and the receiver.lConnect the equipment to an outlet on a circuit different from that to which the receiver is connected.lConsult the dealer or an experienced radio/TV technician for help.To assure continued appliance, any changes or modifications not expressly approved by the party responsible for compliancecould voice the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting tocomputer or peripheral devices).FCC Radiation Exposure StatementThis equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment shouldbe installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons andmust not be co-located or operating in conjunction with any other antenna or transmitter.5Smart-Sync Digital Clock/Timer Install Guide
Radio Standards Specification (RSS)This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:(1) This device may not cause interference; and(2) This device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitationest autorisée aux deux conditions suivantes :(1) l’appareil ne doit pas produire de brouillage;(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’encompromettre le fonctionnement.The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RFexposure, users can obtain Canadian information on RF exposure and compliance.Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS 102 et la conformité àl'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la conformité de rf.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipmentshould be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ou émetteur. Cetéquipement devrait être installé et actionné avec une distance minimum de 20 centimètres entre le radiateur et votre corps.6
European Union Declaration of Conformity and RestrictionsHereby, Primex Inc. declares that this equipment complies with the essential requirements and other relevant provisions ofDirective 1999/5/EC:The Primex Smart-Sync Digital LED Clocks/Timers.This equipment is marked with and can be used throughout the European community.This indicated compliance with the R&TTE Directive 1999/5/EC and meets the relevant parts of following technicalspecifications:lEN 300 328 – Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission Systems; Datatransmission equipment operating in the 2.4GHz ISM band and using spread spectrum modulation techniques;Harmonized EN covering essential requirements under article 3.2 of the R&TTE directive.lEN 301 489-17 – Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Electromagnetic Compatibility(EMC) standard for radio equipment and services; Part 17 Specific Conditions for Wideband Data and HIPERLANEquipment.lEN 60950 – Low Voltage Directive (Safety)lEN 50385 – Product standard to demonstrate the compliances of radio base stations and fixed terminal stations forwireless telecommunication systems with the basic restrictions or the reference levels related to human exposure toradio frequency electromagnetic fields.lIndoor use: maximum power (EIRP*) of 100 mW for the entire 2400-2483.5 MHz frequency band.lOutdoor use: maximum power (EIRP*) of 100 mW for the 2400-2454 MHz band and with maximum power (EIRP*) of 10mW for the 2454-2483 MHz band.Exposure to Radio Frequency Radiation To comply with RF exposure compliance requirements, a separation distance of atleast 20 cm must be maintained between the antenna of this device and all person.The technical documentation relevant to the above equipment will be held at: Primex | 965 Wells Street | Lake Geneva, WI53147 | Phone: 1-800-404-8112Company Representative:Larry Poglitsch, Director of OperationsSigned:7Smart-Sync Digital Clock/Timer Install Guide
Specifications - Smart-Sync Digital Clock/TimerAC Powered Models100 - 240 VAC, 50-60 cycle, supplied with a 10 feet (3.0 m) power cord with a two-prong plugBluetooth® Wireless Communication ProtocolBluetooth® Low Energy (BLE) Wireless Technology, version 4.1Bluetooth Range - up to 80 feet (24.3 meters)Operation12- or 24-hour time displayPM indicator lightAlternating time and date display optionLED dimmer option (100%, 75%, 50%, 25%)Automatically adjusts for Daylight Saving Time (DST)Upon first-power up at installation location, a clock shall go through a self-discovery mode to establish connection to Smart-Sync Bluetooth Wireless Network.Clock connects to Smart-Sync Bluetooth Wireless Network to synchronize its time and download setting updates.If power is interrupted, the clock stops until power resumes. Upon resumption of power, the clock self-corrects to the currenttime. Retains time in memory for up to one (1) hour.EnvironmentOperating Temperature Range: 32° F to 95° F (0° C to 35° C); indoor use onlyStorage Temperature Range: -20° F to 185° F (-29° C to 85° C)Digital Code Blue and Elapsed Timer OperationlCapability of functioning as a normal clock and timer with both count-up and count-down optionslWhen power is applied it begins operating as a digital clockUp counter featureslThe up counter can count up from any preset time to 99:59:59 (99 hours, 59 minutes, 59 seconds)lThe decimal point on the far left (near the 10 hour digit) lights up to indicate up counter functionlThe user can preset count up start timelUp-counters can count from 00:00:00 to 99:59:59 (99 hours, 59 minutes, 59 seconds). The display flashes every second andthe clock beeps for 3 seconds when 99:59:59 is reached.Down counter features8
lThe count-down timer can count down from a preset time to 00:00:00lThe decimal point on the far right (near the minutes/seconds digits) lights up to indicate down counter functionlThe user can preset count-down start timelDown counters can count from 99:59:59 to 00:00:00. The display flashes every second and the clock beeps for 3 secondswhen 00:00:00 is reachedElapsed Timer audible tonelAudible tone only on count-up and count-down eventslFrequency: 3 kHz +/- 0.5 kHz9Smart-Sync Digital Clock/Timer Install Guide
Installation and Operation Overview - Smart-Sync Digital Clock/TimerSmart-Sync Clocks are designed to provide ease of installation - requiring no end-user configuration, simply take-out-of thebox and install. The only operation dependency is its connection to an available Smart-Sync Bluetooth Wireless Network.lSmart-Sync Clocks are equipped with a Bluetooth Low Energy (BLE) Wireless Technology radio component, that allows theclock to establish a wireless connection to a Smart-Sync Bluetooth Wireless Network.lA Smart-Sync Clock is identified by a unique Device ID, allowing each clock to receive its unique Device ID settingsmanaged in OneVue, and also authenticate to a Smart-Sync Bluetooth Wireless Network.lA Smart-Sync Bridge is the only system device that connects to your facility’s network. Upon its network connection, itsends Smart-Sync clock data to OneVue and downloads clock settings, and connects to its NTP time source to receive UTCtime. The Smart-Bridge then sends downloaded clock settings and UTC time to Smart-Sync clocks over the Smart-SyncBluetooth Wireless Network.The sections below define clock operation at time of installation and post-installation.Before you beginConfirm a Smart-Sync Bridge, designated to support the clock installation area, has established a network connection to OneVue.A Smart-Bridge must have connected to OneVue and its NTP Time source to allow Smart-Sync Clocks to receive their time and adaily connection schedule.Installation - Clock Self-DiscoveryUpon first-power up at its installation location, a new clock shall go through a self-discovery process as defined below.1. Clock continuously searches for an available Smart-Sync Bluetooth Wireless Network.2. Upon its connection to a Bluetooth Wireless Network, it establishes a communication path either to another Smart-SyncClock or directly to a Smart-Sync Bridge available within the Bluetooth Wireless Network.3. Clock receives time from either a Smart-Sync Clock or directly from a Smart-Sync Bridge.4. Smart-Sync Bridge receives the new clock Device ID and sends the clock Device ID to OneVue over your facility's networkwithin 30 minutes.5. Upon the Smart-Sync 's connection to OneVue, the new clock Device ID is automatically added to OneVue and the clocksunique Device ID settings are downloaded to the Smart-Sync Bridge.6. Smart-Sync Bridge automatically sends the Device ID settings to the new clock over its connection to the BluetoothWireless Network.Post-Installation OperationUpon completion of the self-discovery process, a Smart-Sync Clock operates as described below.1. Smart-Bridge connects to your facility’s network to download Smart-Sync Clocks’ setting updates from OneVue, andconnects to its NTP time source(s) to receive UTC time.2. Smart-Sync Clocks automatically connect once a day at its system defined daily schedule to a Smart-Sync BluetoothWireless Network. At the time of connection, the clocks' statuses are forwarded to a Smart-Sync Bridge either by itscommunication path to another Smart-Sync Clock or directly to a Smart-Sync Bridge. The clocks receive setting updatesand synchronizes received UTC time to its Time Zone offset and DST rules.3. Smart-Sync Bridge establishes a network connection to your facility's network to forward clock status data to OneVue.10
Installation Requirements - Smart-Sync Digital Clock/TimerRefer to the Important Safety Instructions before installing, operating or performing maintenance of clocks/timers.Note:Any damage to the clock or timer due to improper wiring voids the warranty.Installation requirementsA Smart-Sync Bridge or Smart-Sync Clock/Timer is within 80 feet (24.3 m) from the clock installation location.AC-powered digital clock/timer power specificationsShipped from the factory with a 10 ft (3.0 m) two-prong grounded plug.The two-prong plug may be removed for hardwired (pigtail) installation. Hardwired (pigtail) installation requires a 120V~ powerline in a 4 in. x 4 in. junction box installed by a licensed electrician. Leave a minimum of 6 in. of pigtail inside the junction box.11 Smart-Sync Digital Clock/Timer Install Guide
WarrantyTwo Year Limited WarrantyPrimex warrants this product to be free from defects in materials and workmanship for a standard of two (2) years from the dateof purchase. Primex will at its sole option, repair or replace any components that fail in normal use. Such repairs or replacementswill be made at no charge to the customer for replacement parts. The customer will be responsible for any transportation costs.This warranty does not cover failures due to misuse, abuse, accidental or unauthorized alterations or repairs.The warranties and remedies contained herein are exclusive and in lieu of all other warranties express or implied or statutory,including any liability arising under any warranty or merchantability or fitness for a particular purpose, implied, statutory orotherwise. In no event shall Primex be liable for any incidental, special, indirect or consequential damages, whether resulting fromthe use, misuse or inability to use this product or from defects in the product. Some states do not allow this exclusion orlimitation of incidental or consequential damages so the above limitations or exclusion may not apply to you.To obtain warranty service: If after following the instructions in the product guide, you are certain the product is defective, pleasecontact Primex Technical Support to assist with troubleshooting the issue. If the issue cannot successfully be resolved and theproduct is under warranty, an RMA (Return Material Authorization) will be generated. The RMA form will be provided via emailwith detailed instructions for the return.Primex retains the exclusive right to repair or replace the unit at its sole discretion. All merchandise returned must be shipped toPrimex Attn: Returns Dept., N3211 County Road H, Lake Geneva, WI 53147. Primex retains the exclusive right to repair or replacethe unit at its sole discretion. Such shall be your sole exclusive remedy for any breach of warranty.12
Technical SupportYou may require Technical Support when you have questions about product features, system configuration, or troubleshooting.Support services are delivered in accordance with your organization's support agreement, end user licenses agreements, andwarranties, either with a Primex Certified Sales and Service Partner or directly with Primex.Support through Primex Certified Sales and Service PartnersEnsuring our customers experience excellent service is of utmost importance to Primex. Our network of Certified Sales andService Partners offer technical support services for Primex products.If you have purchased Primex products or have a service agreement with a Primex Partner, they are your primary contact for allTechnical Support inquires.When contacting Primex Technical SupportMake sure you have satisfied the system requirements that are listed in your product documentation. Also, you should be at thecomputer or device on which the problem occurred, in case it's necessary to replicate the problem.When you contact Primex Technical Support, please have the following information available:lCustomer ID/Account NamelProblem description/error messageslDevice hardware informationlTroubleshooting performed before contacting PrimexlRecent network changesPrimex Technical SupportHours 7:00 am to 7:00 pm CST | Monday through FridayTelephone: (800) 404-8112Email: techsupport@primexinc.comFax: (262) 248-0061Web: www.primexwireless.com/support13 Smart-Sync Digital Clock/Timer Install Guide