Princeton FC 446 021 U UAdjustable Fiber Optic Adapter ForSpectraProÒ Monochromators And Spectrographs User Manual To The 5ec5c181 7be5 4ee1 Bbaf 3f441e489978
User Manual: Princeton FC-446-021-U to the manual
Open the PDF directly: View PDF
.
Page Count: 10
| Download | |
| Open PDF In Browser | View PDF |
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.princetoninstruments.com Model FC-446-021-U Adjustable Fiber Optic Adapter for SpectraPro Monochromators and Spectrographs Rev 24.07.09 FC-446-021-U.DOC Description: The FC-446-021-U is an adjustable fiber optic adapter designed for use with SpectraPro series monochromators and spectrographs. It includes an integrated horizontal and vertical adjustment mechanism designed to position fibers at the slit opening. The diagram below shows the FC-446-021-U: Vertical Adjustment Micrometer Horizontal Adjustment Micrometer Fiber Optic Bundle Requirements: The standard FC-0446-021-U adapter does not include a fiber optic bundle. These are available from Princeton Instruments. Mounting the FC-446-021-U to standard SpectraPro Slit Assemblies: Before mounting the fiber optic adapter to the slit assembly, mount the CCD detector to the SpectraPro and adjust the detector for best focus. 1 FC-446-021-U.DOC Fiber Cable Adaptability: The assembly is compatible with 10 mm diameter fiber optic bundles, SMA connectors, and FC connectors. See below. SMA Adapter PN 8401-032-44-20 FC Adapter PN 8401-032-44-23 10 mm sleeve PN 8405-232-05 2 FC-446-021-U.DOC The following procedure is recommended for installing and aligning the FC-446-021-U and fiber optic bundles. 1. Remove the entrance slit shipping cover to expose the slit baffle as shown below. 4 Slotted Screws 2. Using a flat-bladed screwdriver, remove the 4 slotted screws from the slit assembly. 3. Remove the existing baffle from the slit assembly and install the 7/8” round baffle. See photograph below. Open the slit to approximately .5 mm. 3 FC-446-021-U.DOC 4. Mount the fiber optic input assembly with the 4 X 8-32 X 3/8” socket head cap screws provided. Fiber Cable and adapters: There are 4 different fiber cable/adapter set up configurations available for the input of the FC-446-021-U adapter assembly. Determine the type of fiber bundle to be installed. Install the desired fiber bundle as described in Set Up 1, 2, 3 or 4. After the installation, proceed to the Alignment Procedure on page 8. 4 FC-446-021-U.DOC Set Up 1: FC Fiber Cable If the fiber cable has a single FC fiber, attach the FC adapter as shown below. Single fiber FC Cable FC Cable attached to FC Adapter Gently slide the cable/fiber assembly into the fiber optic input assembly so the end of the fiber adapter contacts the slits. Now pull the adapter back approximately .1 mm so it is no longer contacting the slits. Lock the fiber into place by tightening down the 3 set screws on the fiber optic input assembly. Do not move the cable so it contacts the slits while you are locking it into place. Contact with the slits can make them inoperable. Locking Set Screws Lock the Cable/Adapter into place with the 3 set screws. CAUTION: Never force the fiber optic bundle against the slits or permanent damage may result. 5 FC-446-021-U.DOC Set Up 2: SMA Fiber Cable If the fiber cable has a single SMA fiber, attach the SMA adapter as shown below. Single Fiber SMA Cable SMA Cable attached to SMA Adapter Gently slide the cable/fiber assembly into the fiber optic input assembly so the end of the fiber adapter contacts the slits. Now pull the adapter back approximately .1 mm so it is no longer contacting the slits. Lock the fiber into place by tightening down the 3 set screws on the fiber optic input assembly. Do not move the cable so that it contacts the slits while you are locking it into place. Contact with the slits can make them inoperable. Locking Set Screws Lock the Cable/Adapter into place with the 3 set screws. CAUTION: Never force the fiber optic bundle against the slits or permanent damage may result. 6 FC-446-021-U.DOC Set Up 3: 10 mm Diameter Sleeve with a single fiber Install the 10 mm sleeve to the X-Y adapter and lock it into place by tightening down the 3 set screws surrounding the adapter. Now gently slide the cable/fiber into the entrance of the fiber optic input assembly so the end of the fiber adapter contacts the slits. Now pull the adapter back approximately .1 mm so it is no longer contacting the slits. Lock the fiber into place by tightening down the set screw on the 10 mm sleeve. See below. CAUTION: Never force the fiber optic bundle against the slits or permanent damage may result. 7 FC-446-021-U.DOC Set Up 4: 10 mm Diameter Sleeve with multiple fibers aligned in a row Install the 10 mm sleeve to the X-Y adapter and lock it into place by tightening down the 3 set screws surrounding the adapter. Note the orientation of the fibers in the sleeve of the fiber cable. Orient the fibers vertically and gently slide the cable/fiber into the entrance of the fiber optic input assembly so the end of the fiber adapter contacts the slits. Now pull the adapter back approximately .1 mm so it is no longer contacting the slits. Verify that the fibers are aligned vertically and then tighten down the set screw. Alignment Procedure: 1. Adjust the vertical adjustment micrometer until the image of the fiber is centered in the height of the CCD or the center of the exit slit. 2. Slowly reduce the entrance slit width to approximately the fiber core diameter of the fiber while adjusting the horizontal adjustment micrometer to center the fiber on the entrance slit for maximum signal. Note: If the fiber bundle consists of a series of fibers aligned vertically, it may be necessary to rotate the fiber to vertically align the fibers with the slit during this procedure. 3. The fiber is now properly aligned. 8 FC-446-021-U.DOC 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.princetoninstruments.com RECOMMENDED MINIMUM BEND RADIUS FOR FUSED SILICA FIBERS: Fiber Diameters MICRONS 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1000 1100 1200 1300 1400 1500 1600 Momentary Min. INCHES Bend Radius MILLIMETERS 0.20 0.39 0.59 0.79 0.98 1.18 1.38 1.58 1.77 1.97 2.16 2.35 2.55 2.75 2.95 3.15 3.54 3.94 4.33 4.72 5.12 5.51 5.90 6.30 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 90 100 110 120 130 140 150 160 Long Term Min. INCHES 0.59 1.18 1.77 2.36 2.95 3.54 4.13 4.72 5.31 5.90 6.50 7.09 7.98 8.27 8.86 9.45 10.63 11.81 12.99 14.17 15.35 16.54 17.72 18.90 Bend Radius MILLIMETERS 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 270 300 330 360 390 420 450 480 Minimum bend DIAMETER is equal to the radius X2. Momentary means minutes. 9 FC-446-021-U.DOC
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : Princeton Instruments, a division of Roper Scientific, Inc. Description : Rev 24.07.09 Title : Model FC-446-021-UAdjustable Fiber Optic Adapter forSpectraProÒ Monochromators and Spectrographs Create Date : 2009:07:24 21:49:59Z Creator Tool : Microsoft® Office Word 2007 Modify Date : 2009:07:24 17:56:01-04:00 Metadata Date : 2009:07:24 17:56:01-04:00 Producer : Microsoft® Office Word 2007 Document ID : uuid:344ba1e6-1011-4ce8-b6ca-f6958d3e623b Instance ID : uuid:bcb043b7-fdc1-4cea-8b44-60a2fe78ce49 Page Layout : SinglePage Page Count : 10 Author : Princeton Instruments, a division of Roper Scientific, Inc. Subject : Rev 24.07.09 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools