Psion RD7950 INTEGRATED UHF RFID READER User Manual RD7950 Integrated UHF RFID Reader QSG

Psion Inc INTEGRATED UHF RFID READER RD7950 Integrated UHF RFID Reader QSG

USERS MANUAL

RD7950Integrated UHF RFID ReaderQuick Start GuideFebruary 24, 2005 PN 8100056.ADRAFTISO 9001 CertifiedQuality Management System
© Copyright 2005 by Psion Teklogix Inc., Mississauga, Ontario, CanadaThis document and the information it contains is the property of Psion Teklogix Inc., is issued in strict confidence, and is not to be reproduced orcopied, in whole or in part, except for the sole purpose of promoting the saleof Psion Teklogix manufactured goods and services. Furthermore, this docu-ment is not to be used as a basis for design, manufacture, or sub-contract, orin any manner detrimental to the interests of Psion Teklogix Inc.All trademarks are the property of their respective holders.
Return-To-Factory WarrantyPsion Teklogix warrants a return-to-factory warranty for a period of one year.In some regions, the warranty exceeds this period. Please contact your localPsion Teklogix office for details. For a list of offices, refer to “Support Ser-vices & Worldwide Offices” on page 13. The warranty on Psion Teklogixmanufactured equipment does not extend to any product that has been tam-pered with, altered, or repaired by any person other than an employee of anauthorized Psion Teklogix service organization. See Psion Teklogix termsand conditions of sale for full details.ServiceWhen requesting service, please provide information concerning the natureof the failure and the manner in which the equipment was used when the fail-ure occurred. Type, model, and serial number should also be provided.Before returning any products to Psion Teklogix, please call the CustomerServices Group for a Return Authorization number. Support ServicesPsion Teklogix provides a complete range of product support services to itscustomers. For detailed information, please refer to “Support Services &Worldwide Offices” on page 13.DisclaimerEvery effort has been made to make this material complete, accurate, and up-to-date. Psion Teklogix Inc. reserves the right to make changes without noticeand shall not be responsible for any damages, including but not limited toconsequential damages, caused by reliance on the material presented, includ-ing but not limited to typographical errors.
Psion Teklogix RD7950 Quick Start Guide 1                                                                                                                                                                                    Table Of Contents                                           FCC Interference Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.  Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.  Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.1  Flexibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.2  Ruggedness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.3  Ergonomics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53.  Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53.1  Enabling The RD7950 . . . . . . . . . . . . . . . . . . . . . . . . . 94.  Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104.1  Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . 104.2  Terminal Interface  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104.3  Programming Environment  . . . . . . . . . . . . . . . . . . . . . 104.4  RFID Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104.5  Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . 105.  Support Services & Worldwide Offices . . . . . . . . . . . . . . . . 135.1  Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135.2  Product Repairs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135.3  Worldwide Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Psion Teklogix RD7950 Quick Start Guide                                                                                                                       FCC Interference StatementThis equipment complies with Class B, Part 15 of the FCC rules. Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.Changes or modifications not expressly approved by Psion Teklogix, the party responsible for compliance, may void the user's authority to operate the equipment.1. FCC Information to UsersFor Class B Unintentional Radiators:This equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection againstharmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequencyenergy and, if not installed and used in accordance with the instruc-tion manual, may cause harmful interference to radio communica-tions. However, there is no guarantee that interference will not occurin a particular installation. If this equipment does cause harmful inter-ference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to cor-rect the interference by one of more of the following measures:• Reorient or relocate the receiving antenna• Increase the separation between the equipment and receiver
Psion Teklogix RD7950 Quick Start Guide 3• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.2. Warning to UsersChanges or modifications not expressly approved by Psion Teklogix Inc. could void the user's authority to operate the equipment.Emissions Information For CanadaThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.                                                                                                                        SafetyThe RD7950 Integrated UHF RFID Reader is intended for use with the Psion Teklogix 7535 Hand-Held Computer.Warning: The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
4 Psion Teklogix RD7950 Quick Start Guide                                                                                                                       1.  IntroductionThe RD7950 Integrated UHF RFID Reader is an EPC-compliant 900MHz RFID reader available for use with the Psion Teklogix 7535 Hand-Held Computer. The RD7950 meets the EPC-compliance requirements of Wal-Mart and the U.S. Department of Defense, while leveraging existing hardware infrastructures. Multimedia data capture capabilities are delivered by combining RFID with existing technolo-gies such as laser bar code scanning or imaging.2.  Features2.1  Flexibility Compatible with EPC Class 0, 0+, and Class 1, as well as the ISO 18000-6 B protocol, the RD7950 delivers outstanding flexibility. Delivers multimedia data capture capabilities since the RD7950, and laser bar code scanning or imaging capabilities, can be integrated into a single hand-held device.2.2  RuggednessThe rugged design of the RD7950 delivers overall system up-time for increased productivity even in harsh environments. The RD7950 is rated at IP54, protected against dust and water sprayed from all directions. Combined with a 1.22 m (4 ft.) drop rating to concrete, 26 times, the RD7950 will keep working even when subjected to harsh impacts.
Psion Teklogix RD7950 Quick Start Guide 52.3  ErgonomicsWell balanced, lightweight, and with an easy-to-handle pistol grip, the RD7950 is easy to use for a full shift.3.  InstallationTo install the RD7950 Integrated UHF RFID Reader to the 7535 Hand-Held Computer, first attach the pistol grip.Figure 3.1 RD7950 Installation ComponentsPistol Grip 7535 Hand-Held RD7950Long ScrewPlug
6 Psion Teklogix RD7950 Quick Start GuideAttaching The Pistol GripNotes: A Phillips head screwdriver is required. Do not use adhe-sives such as Loctite to secure the screws on carrying acces-sories. These chemicals may damage the plastic casing.The pistol grip is attached to the back of the 7535 Hand-Held Computer using the four threaded inserts in the upper part of the 7535 casing. Four black #4-40 Phillips head screws are provided with this acces-sory: two for insertion into the bottom holes, and two for insertion into the top holes through the RD7950 when attaching it to the 7535/pistol grip assembly (see page 7). Note: Prior to installation, make sure the trigger mechanism is securely snapped into the pistol grip body and that the trigger operates properly. • Position the pistol grip so that it fits snugly over the back of the unit and the inserts on the back of the 7535 align with the holes in the pistol grip. • Using a Phillips screwdriver, securely fasten the pistol grip to the two bottom holes on the back of the 7535. Tighten the screws to a torque of 3kgf-cm (3 lbs-in), or until finger-tight, to secure the pistol grip in place.
Psion Teklogix RD7950 Quick Start Guide 7Figure 3.2 Pistol Grip Attachment To 7535 Hand-Held ComputerAttaching The RD7950• Push the plug through the pistol grip, with the hole in the plug towards the front.Figure 3.3 • Attach the RD7950 to the 7535/pistol grip assembly by screw-ing it on with the top screws.Top  Scr ew s(to be inserted throughthe RD7950) Bottom Screws
8 Psion Teklogix RD7950 Quick Start Guide• Screw the long screw through the pistol grip.Figure 3.4 • Plug the RD7950 into the tether port.Figure 3.5
Psion Teklogix RD7950 Quick Start Guide 9Figure 3.6 RD7950 Installed On 7535 Hand-Held Computer3.1  Enabling The RD7950• In the 7535 unit, when the trigger source is selected for RFID usage, pulling the trigger causes a Scanning icon to appear. While that icon is displayed, the RD7950 is powered on and actively probing for RFID tags. • When the trigger is released, the image will disappear, and the RD7950 is powered down.
10 Psion Teklogix RD7950 Quick Start Guide                                                                                                                       4.  Product Specifications*Specifications subject to change.4.1  Standards ComplianceEPC Class 0, 0+ and Class 1ISO 18000-6 Type B (U-Code, HSL)Software upgradeable to UHF Gen 2BiStar, EM, Impinj Zuma4.2  Terminal Interface7535 Hand-Held Computer4.3  Programming EnvironmentWindows® Win32 File API4.4  RFID ApplicationsPsion Teklogix RFID File System4.5  Technical SpecificationsFrequency Range:  902 to 928MHz Transmitter Power Output: 1Watt (30dBm)Channel Spacing:  500kHzChannel Bandwidth:  Class 0: 205kHzClass 1: 300kHzISO18000-6: 70kHz
Psion Teklogix RD7950 Quick Start Guide 11Number of Hops:  50Data Rate:  57600Input Voltage:  5VCurrent Rating:  1.5ARead DistanceClass 0, 2x2 tag:  0 - 2.5 m (0 - 8 ft.)Class 0, l1020:  0 - 3 m (0 - 10 ft.)Class 0+ 4x4:  0 - 3.5 m (0 - 11 ft.)Class 1 9238 Squiggle:  0 - 2.5 m (0 - 8 ft.)Class 1 9338:  0 - 3.5 m (0 - 11 ft.)Read distance is highly dependant upon tag configuration, material to which the tag is applied, and the presence of metal and water around the tag. Metal and water will decrease read ranges significantly. Write DistanceWrite distance for Class 0+ and Class 1 tags is approximately 50% of the read distance referenced above. WeightLess than 1400g 7535 is approximately 775g (27oz.) with pistol grip.Integrated Reader is approximately 600g (21oz.).
12 Psion Teklogix RD7950 Quick Start GuideEnvironmentalOperating temp:  0°C to +50°C (32°F to 122°F)Storage temp:  -25°C to +60°C (-13°F to 140°F)Humidity:  5 - 95% RH, non-condensingRain/Dust:  IEC 529, classification IP54Shock:  1.22 m (4 ft.) drop to polished concrete multiple timesCradle vibration:  1.5g RMS PSD (4 Hz - 500 Hz)ApprovalsIndustry Canada RSS-210FCC Part 15Safety: UL 1950, CSA C22.2 No950, LVD EN60950EMC: FCC Part 15 Class B, EMC Directive Class B
Psion Teklogix RD7950 Quick Start Guide 13                                                                                                                       5.  Support Services & Worldwide OfficesPsion Teklogix provides a complete range of product support ser-vices to its customers worldwide. These services include technical support and product repairs.5.1  Technical SupportTechnical Support for Mobile Computing Products is provided via e-mail through the Psion Teklogix customer and partner extranets. To reach the website, go to www.psionteklogix.com and click on the appropriate Teknet link on the home page. Then click on the “Log-in” button or the “Register” button, depending on whether you have previously registered for Teknet. Once you have logged in, search for the “Support Request Form”.5.2  Product RepairsInternationalFor technical support outside of Canada or the U.S.A., please contact your local Psion Teklogix office listed on our worldwide website:http://www.psionteklogix.comClick on the heading labelled “Contacts” to choose a Psion Teklogix technical support representative closest to you. Canada/U.S.ACanadian and U.S. customers can receive access to repair services, by calling the toll-free number below, or via our secure website (see Technical Support, above).
14 Psion Teklogix RD7950 Quick Start GuideNote: Customers calling the toll-free number should have their Psion Teklogix customer number or trouble ticket number available.Voice: 1 800 387-8898 (press option “2”)Fax: 1 905 812-6304 5.3  Worldwide OfficesCOMPANY HEADQUARTERS AND CANADIAN SERVICE CENTREPsion Teklogix Inc.2100 Meadowvale Blvd.Mississauga, OntarioCanada L5N 7J9Tel: +1 905 813 9900Fax: +1 905 812 6300E-mail: salescdn@psion.comNORTH AMERICAN HEADQUARTERS AND U.S. SERVICE CENTREPsion Teklogix Corp.1810 Airport Exchange BoulevardSuite 500Erlanger, KentuckyUSA 41018Tel: +1 859 371 6006Fax: +1 859 371 6422E-mail: salesusa@psion.com
Psion Teklogix RD7950 Quick Start Guide 15INTERNATIONAL SUBSIDIARIES (SEE ALSO WWW.PSIONTEKLOGIX.COM)Psion Teklogix S.A.La Duranne135 Rue Rene DescartesBP 42100013591 Aix-En-ProvenceCedex 3; FranceTel: +33 4 42 90 88 09Fax: +33 4 42 90 88 88E-mail: tekeuro@psion.com

Navigation menu