Submittal Data Information 101-084 Model 0011-IFC® Cartridge Circulator Effective: April 22, 2010 Features s )NTEGRAL &LOW #HECK )®) Prevents gravity flow Eliminates separate in-line flow check Reduces installed cost, easy to service Improved performance vs. In-line flow checks s 5NIQUE REPLACEABLE CARTRIDGE &IELD SERVICEABLE s 5NMATCHED RELIABILITY -AINTENANCE FREE s 1UIET EFFICIENT OPERATION s $IRECT DRIVE ,OW POWER CONSUMPTION s 3ELF LUBRICATING .O MECHANICAL SEAL s 3TANDARD HIGH CAPACITY OUTPUT #OMPACT DESIGN s 7IDE RANGE OF APPLICATIONS s #AST )RON OR 3TAINLESS 3TEEL CONSTRUCTION Flanged connections Materials of Construction #ASING 6OLUTE #AST )RON OR 3TAINLESS 3TEEL Integral Flow Check: Body, Plunger....Acetal / RING 3EALS%0$Spring.................Stainless Steel Stator Housing: Aluminum Cartridge: Stainless Steel )MPELLER .ON -ETALLIC Shaft: Ceramic Bearings: Carbon / 2ING 'ASKETS %0$- Model Nomenclature F – Cast Iron, Flanged SF – Stainless Steel, Flanged IFC – Integral Flow Check Variations: Z – Zoning Circulator J – Bronze Cartridge with Cast Iron Casing IMP. DIA. For Indoor use only HEAD/FT. H.P. ELEC. CHAR. Application The 0011-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00® circulators on large residential or light commercial high head / medium flow applications such as hydronic or radiant heating, hydro-air fan coils, indirect water heaters or domestic water recirculation systems. By locating the removable, spring-loaded IFC inside the pump casing, a separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the IFC increases the 0011 flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit. Our patented Priority Zoning circulator with built-in transformer, relay, priority switch and IFC in one complete, compact package makes it ideal for zoning. Pump Dimensions & Weights ! -ODEL Casing 0011-F4-2 IFC 0011-SF4-IFC 0011-ZF4-1 IFC 0011-ZSF4-IFC Iron St. Steel Iron St. Steel in. " in. mm mm # in. mm $ in. & mm in. mm in. ' 3HIP 7T mm lbs. Kg 13 6.0 Mounting Positions Standard Optional OK if over 20 psi Flange Orientation Electrical Data -ODEL 6OLTS (Z 0H !MPS 20- (0 !LL -ODELS -OTOR Type -OTOR Options 0ERMANENT 3PLIT #APACITOR Impedance Protected Performance Field - 60Hz INTEGRAL FLOWCHECK (IFC ) MODELS ® FLOW-M3/H TOTAL HEAD-FEET Performance Data &LOW 2ANGE '0Head Range: 0 - 31 Feet -INIMUM &LUID 4EMPERATURE & # -AXIMUM &LUID 4EMPERATURE ª& # -AXIMUM 7ORKING 0RESSURE PSI Connection Sizes: 3/4”, 1”, 1-1/4”, 1-1/2” Flanged G.P.M. 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 11.0 36 10.5 34 009-IFC 10.0 32 0010-IFC 9.5 0011-IFC 30 9.0 0012-IFC 28 8.5 0013-IFC 8.0 26 0014-IFC 7.5 24 7.0 22 6.5 20 6.0 5.5 18 5.0 16 4.5 14 4.0 12 3.5 10 3.0 2.5 8 2.0 6 1.5 4 1.0 2 0.5 0 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 TOTAL HEAD-METERS MODEL NO. Rep: Contractor: ® ITEM NO. Supersedes: June 27, 2007 Effective: 04/22/10 Submittal Data # 101-084 Supersedes: 06/27/07 Submittal Data Information Job: Engineer: Circulator Model 0011-IFC Cartridge FLOW-GPM .3& n ,EAD Complies with California Health and Safety #ODE 3ECTION !" AND Vermont Act 193 Do it Once. Do it Right.® TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360 TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436 Visit our website at: www.taco-hvac.com Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436 www.taco-hvac.com Printed in USA Copyright 2010 TACO, Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : 3.1.1-111 About : 2bf26d1a-d42f-11d9-ad04-895864b2f99e Create Date : 2010:04:28 11:22:40-04:00 Modify Date : 2010:04:28 11:22:48-04:00 Metadata Date : 2010:04:28 11:22:48-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 14560 bytes, use -b option to extract) Version ID : 1 Instance ID : uuid:e780097b-52d9-11df-8bf4-0011247ebd3a Document ID : adobe:docid:indd:d06386f1-5447-11df-9847-ace55243cfae Rendition Class : proof:pdf Derived From Instance ID : 6784f7a3-21fd-11df-853d-e40a8b296edc Derived From Document ID : adobe:docid:indd:1be864c5-e1d8-11da-b67c-93509d64ddaf Derived From Version ID : 1 Manifest Link Form : ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches Manifest Reference Instance ID : uuid:e53f7caa-52d5-11df-99ba-0011247ebd3a, uuid:37A021BA067611DA8DBAAA8852931B3F Manifest Reference Document ID : uuid:c23e740e-52d5-11df-99ba-0011247ebd3a, uuid:37A021B9067611DA8DBAAA8852931B3F Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 1 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools