12777 2 Taco 009 Sf5 Ifc Product Overview User Manual
User Manual: Pump 12777 2 Taco 009-Sf5-Ifc Product Overview
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
Water Circulation Pumps & Circulators Model 009-IFC Cartridge Circulator ® The High Velocity series Taco 009-IFC cartridge circulator includes an Integral Flow Check (IFC®). The patented, removable IFC replaces a separate in-line flow check, saving installation costs while improving system performance. The 009-ZF-IFC features our Priority Zone control with built-in transformer, relay and priority switch making it an ideal choice when zoning with circulators. Available in Cast Iron or Stainless Steel construction. ©Taco Catalog #100-29 Supersedes: 06/01/04 Effective Date: 02/10/09 Printed in USA Submittal Data # 101-099 Supersedes: 06/01/04 Submittal Data Information Model 009-IFC® Cartridge Circulator Features • Integral Flow Check (IFC®) Prevents gravity flow Eliminates separate in-line flow check Reduces installed cost, easy to service Improved performance vs. In-line flow checks • Optional Priority Zoning control • Unique replaceable cartridge-Field serviceable • Unmatched reliability-Maintenance free • Quiet, efficient operation • Direct drive - Low power consumption • Self lubricating, No mechanical seal • Standard high capacity output - Compact design • Wide range of applications • Cast Iron or Stainless Steel construction, Flanged connections Materials of Construction Casing (Volute): Cast Iron or Stainless Steel Integral Flow Check: Body, Plunger....Acetal O-ring Seals......EPDM Spring.................Stainless Steel Stator Housing: Aluminum Cartridge: Stainless Steel Impeller: Non-Metallic Shaft: Ceramic Bearings: Carbon O-Ring & Gaskets: EPDM Model Nomenclature F – Cast Iron, Flanged SF – Stainless Steel, Flanged IFC – Integral Flow Check Variations: Z – Zoning circulator J – Bronze cartridge with Cast Iron casing Effective: 02//09 Application The Taco 009-IFC with Integral Flow Check (IFC®) is designed to reduce installation costs when zoning with 00® circulators on a wide range of residential and light commercial higher-head/ lower-flow water circulating applications. Typical uses include hydronic heating, radiant in-floor/ panel heating and closed-loop solar heating systems. The Stainless Steel 009-IFC can be used in higher-head/lower-flow heat recovery, open-loop solar heating and light commercial domestic water recirculation systems. The unique replaceable cartridge contains all of the moving parts and allows for easy service instead of replacing the entire circulator. Available with optional Priority Zoning controls. Pump Dimensions & Weights Model A Casing in. mm 009-F5-IFC Cast Iron 7 009-SF5-IFC St. Steel 7 009-ZF5-1 IFC Cast Iron 7 009-ZSF5-IFC St. Steel 7 178 178 178 178 B in. mm 5-11/16 5-11/16 5-11/16 5-11/16 144 144 144 144 C in. mm 3-3/16 3-3/16 3-3/16 3-3/16 81 81 81 81 D F G Ship Wt. in. mm in. mm in. mm lbs. Kg 3-3/8 3-3/8 3-13/16 3-13/16 86 86 97 97 5-1/2 5-1/2 6 6 140 140 153 153 Standard Electrical Data Model 009-F5-IFC 009-SF5-IFC Optional Flange Orientation Volts Hz 115 115 60 60 Ph Amps RPM 1 1 1.40 1.40 3250 3250 HP 1/8 1/8 Motor Permanent Split Capacitor Type Impedance Protected Motor Options 220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1 Performance Field - 60Hz INTEGRAL FLOWCHECK (IFC ) MODELS ® For Indoor use only 162 162 162 162 9.5 9.5 10.5 10.5 4.3 4.3 4.7 4.7 Mounting Positions Performance Data 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 11.0 36 10.5 34 009-IFC 10.0 32 0010-IFC 9.5 0011-IFC 30 9.0 0012-IFC 28 8.5 0013-IFC 8.0 26 0014-IFC 7.5 24 7.0 22 6.5 20 6.0 5.5 18 5.0 16 4.5 14 4.0 12 3.5 10 3.0 2.5 8 2.0 6 1.5 4 1.0 2 0.5 0 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 TOTAL HEAD-METERS FLOW-M3/H TOTAL HEAD-FEET Flow Range: 0 – 10 GPM Head Range: 0 – 35 Feet Minimum Fluid Temperature: 40˚F (4˚C) Maximum Fluid Temperature: 230°F (110˚C) Maximum Working Pressure: 125 psi Connection Sizes: 3/4", 1", 1-1/4", 1-1/2" Flanged 6-3/8 6-3/8 6-3/8 6-3/8 FLOW-GPM Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436 www.taco-hvac.com OK if over 20 psi
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2009:04:23 10:11:41-04:00 Creator : Adobe InDesign CS4 (6.0.1) Modify Date : 2013:04:19 10:28:51-04:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2013:04:19 10:28:51-04:00 Creator Tool : Adobe InDesign CS4 (6.0.1) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 9287 bytes, use -b option to extract) Document ID : xmp.did:9E8B5F352E206811871FD1C5C73DAEFD Instance ID : uuid:17340947-e73b-47b1-a3b9-aa51f55d0159 Original Document ID : adobe:docid:indd:071ef1e6-b0bc-11d8-9cfa-950606625b88 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9D8B5F352E206811871FD1C5C73DAEFD Derived From Document ID : adobe:docid:indd:071ef1e6-b0bc-11d8-9cfa-950606625b88 Derived From Original Document ID: adobe:docid:indd:071ef1e6-b0bc-11d8-9cfa-950606625b88 Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:0F0F1C8329206811871FD1C5C73DAEFD, xmp.iid:100F1C8329206811871FD1C5C73DAEFD, xmp.iid:110F1C8329206811871FD1C5C73DAEFD, xmp.iid:120F1C8329206811871FD1C5C73DAEFD, xmp.iid:968B5F352E206811871FD1C5C73DAEFD, xmp.iid:978B5F352E206811871FD1C5C73DAEFD, xmp.iid:988B5F352E206811871FD1C5C73DAEFD, xmp.iid:998B5F352E206811871FD1C5C73DAEFD, xmp.iid:9A8B5F352E206811871FD1C5C73DAEFD, xmp.iid:9B8B5F352E206811871FD1C5C73DAEFD, xmp.iid:9C8B5F352E206811871FD1C5C73DAEFD, xmp.iid:9D8B5F352E206811871FD1C5C73DAEFD, xmp.iid:9E8B5F352E206811871FD1C5C73DAEFD, xmp.iid:9F8B5F352E206811871FD1C5C73DAEFD, xmp.iid:A08B5F352E206811871FD1C5C73DAEFD, xmp.iid:C945703D132068118855F914247DDD18, xmp.iid:CA45703D132068118855F914247DDD18, xmp.iid:034C1C4130206811871FE5B6A34241EB History When : 2009:02:06 13:55:04-05:00, 2009:02:06 13:55:04-05:00, 2009:02:06 13:59:20-05:00, 2009:02:06 14:05:10-05:00, 2009:02:06 14:06:35-05:00, 2009:02:06 14:09:45-05:00, 2009:02:06 14:12:07-05:00, 2009:02:06 14:15:06-05:00, 2009:02:06 14:15:40-05:00, 2009:02:06 14:17:40-05:00, 2009:02:06 14:18:11-05:00, 2009:02:06 14:18:36-05:00, 2009:02:06 14:18:36-05:00, 2009:02:06 14:19:51-05:00, 2009:02:06 14:20:42-05:00, 2009:02:10 11:24:06-05:00, 2009:02:10 11:24:41-05:00, 2009:04:23 10:11:27-04:00 History Software Agent : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0 History Changed : /, /metadata, /, /, /, /, /, /, /, /, /, /metadata, /, /, /, /, /, / Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:217196a3-c04a-11d8-a91f-a9f068348985, uuid:217196a6-c04a-11d8-a91f-a9f068348985, xmp.iid:028011740720681191B1FE62C36E7416, uuid:DA12795C91DD11DBADF08BBD8FB06D23, xmp.iid:028011740720681191B1FE62C36E7416 Manifest Reference Document ID : adobe:docid:photoshop:7cb29c0e-ba19-11d8-bfe4-d7b583cbba08, adobe:docid:photoshop:55f80a4a-bac2-11d8-a6d9-aa15dd01bdc8, xmp.did:028011740720681191B1FE62C36E7416, uuid:DCED90F691BA11DBADF08BBD8FB06D23, xmp.did:028011740720681191B1FE62C36E7416 Doc Change Count : 278 Format : application/pdf Producer : Adobe PDF Library 9.0 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools