Open system vs closed? Barrier vs non-barrier tubing? Boiler vs water heater?
The debate ends here. The patent pending X-Pump Block combines a variable speed mixing control, heat source
circulator, system circulator, and heat exchanger into a single unit. This combination delivers complete isolation
between the heat generation side of the system (boiler, water heater, etc.) and the heat delivery side of the system
(radiant tubing, glycol based snowmelt, baseboard, etc.). Just four pipe connections and your installation is complete.
X-Pump Block
Effective: 8/15/05
Printed in the USA
Taco Catalog # 100-39
Supersedes: NEW
Water Circulation
Pumps & Circulators
Application
The X-Pump Block (XPB) is a complete mixing system with an attached brazed plate, counterflow
style heat exchanger for system isolation. Integral to the unit is a variable speed heat source circulator,
constant speed system circulator and the electronics to drive it all. The XPB can be set up to operate
as an outdoor reset control, a setpoint control or a delta T limiting control. This unparalleled flexibility
within a single unit creates a pumping and control package that can be used in systems combining any
style heat source (boiler, water heater, etc.) with any style heat delivery method or system condition
(radiant tubing, glycol based snowmelt, open system, etc.). With just 4 piping connections needed, the
XPB greatly reduces the time and space required for installation.
The features of the X-Pump Block makes it easy and cost effective to include a hydronic based radiant
floor warming system in any kitchen and bath remodel project, especially in homes which have an air based
heating system. The XPB also makes the perfect companion for basement “radiant ready” packages, jobs
where space is at a premium, and small snowmelt areas such as handicap accessible building entrances.
Operation
Hot water from the heat source, such as a boiler, enters the X-Pump Block’s integral heat exchanger
at port (A1) and exists at (A2). The variable speed circulator controls the speed of the water flowing
through the A side of the heat exchanger to satisfy the heat transfer requirements between the A side
of the heat exchanger and the B (system) side. The heat exchanger is a counterflow style, so system
water enters at port (B1) and exits at port (B2). A constant speed
circulator moves the water around the B (system) side. In
certain applications, such as snowmelt, the system pump motor
can be switched with the variable speed motor in order to
protect the heat exchanger from freezing up by ensuring
constant flow on the heat source side.
Sizing and Piping
The X-Pump Block can handle transfer loads of up to approximately
50,000 BTU. Your current method of piping virtually remains the
same; yet complete system isolation is achieved. The only addition
needs to be a separate expansion tank and relief valve on the system
side. 1 outdoor sensor, 2 strap-on sensors and a line cord are
included for fast plug n’ play wiring.
Supply
Sensor
Outdoor
Sensor
Conventional Heat Exchanger Piping
Boiler
Sensor
Input From
Heat Source
Output
to System
HEAT
SOURCE
Submittal Data # 101-111
Supersedes: New
Effective: 8/15/05
)mpg( WOLF
0186420
HEAD (ft)
0
2
4
6
8
0
1
21
41
6
1
81
Performance Field
Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
HYDRONIC COMPONENTS & SYSTEMS
Submittal Data Information
X-Pump Block
Features
All-in-One Heat Exchanger, Dual-sided
Circulators and Mixing Control Package
Brazed Plate Heat Exchanger
Provides Complete Isolation
Stainless Steel
Easily Removable
Double Wall Optional
Only 4 Pipe Connections Required
Plug-in Low Voltage Connections
Solid State Microprocessor Design
Greatly Decreases Installation Time
Substantial Space Savings
Line Cord Included, Hard Wire Option
Bronze Casing for Open or Closed Systems
Replaceable Cartridge Design
Maintenance Free, Wet-Rotor Circulators
2 Operation Modes: Outdoor Reset and
Setpoint with or without Delta T Limiting
Main System Pump Contact
100% Pump Operation / Control Override
Switch
Automatic Pump Exercise
Adjustable Reset Ratio
Warm Weather Shutdown
Large LCD Display
Outdoor and 2 Strap-on Sensors included
Performance Data
Flow Range: 0 7.5 GPM
Head Range: 0 – 15.5 Feet
Minimum Fluid Temperature: 32˚F (0˚C)
Maximum Fluid Temperature: 185°F (85˚C)
Maximum Working Pressure: 125 psi
Connection Sizes: 3/4” NPT
FOR INDOOR USE ONLY
Model Volts Hz Ph
Amps RPM HP
XPB-1 120 60 1 2
3250
2 @ 1/25
Motor Permanent Split Capacitor
Type Impedance Protected
Electrical & Weight Data
Ship Wt.
lbs.
Kg
26.5
12.0
X - Pump Block (XPB)
Input from
Heat Source
Output to
System
HEAT
SOURCE Supply
Sensor
Return
Sensor
Outdoor
Sensor
Exp
Tank
Pressure
Relief
X
- Pump Block (XPB), Multiple Zones - Circulators
Input from
Heat Source
Output to
System
HEAT
SOURCE Supply
Sensor
Return
Sensor
Outdoor
Sensor
Exp
Tank
Pressure
Relief
X
- Pump Block (XPB), Multiple Zones - Zone Valves
Input from
Heat Source Output to
System
HEAT
SOURCE Supply
Sensor
Return
Sensor
Outdoor
Sensor
Exp
Tank
Pressure
Relief
M
M
A1
A2
B1
B2
Heat Source
Side Circulator
System Side
Circulator