Submittal Data Information

101-111

X-Pump Block

Effective: August 15, 2005
Job:

Supersedes:
%FFECTIVE
 New

3UBMITTAL $ATA   
3UPERSEDES .EW

Rep:

Contractor:

Engineer:
3UBMITTAL $ATA )NFORMATION
ITEM NO.
MODEL NO.
8 0UMP
"LOCK

!PPLICATION

&EATURES

s !LL IN /NE (EAT %XCHANGER $UAL SIDED
#IRCULATORS AND -IXING #ONTROL 0ACKAGE
s "RAZED 0LATE (EAT %XCHANGER
0ROVIDES #OMPLETE )SOLATION
3TAINLESS 3TEEL
%ASILY 2EMOVABLE
$OUBLE 7ALL /PTIONAL
s /NLY  0IPE #ONNECTIONS 2EQUIRED
s 0LUG IN ,OW 6OLTAGE #ONNECTIONS
s 3OLID 3TATE -ICROPROCESSOR $ESIGN
s 'REATLY $ECREASES )NSTALLATION 4IME
s 3UBSTANTIAL 3PACE 3AVINGS
s ,INE #ORD )NCLUDED (ARD 7IRE /PTION
s "RONZE #ASING FOR /PEN OR #LOSED 3YSTEMS
s 2EPLACEABLE #ARTRIDGE $ESIGN
s -AINTENANCE &REE 7ET 2OTOR #IRCULATORS
s  /PERATION -ODES /UTDOOR 2ESET AND
3ETPOINT WITH OR WITHOUT $ELTA 4 ,IMITING
s -AIN 3YSTEM 0UMP #ONTACT
s  0UMP /PERATION  #ONTROL /VERRIDE
3WITCH
s !UTOMATIC 0UMP %XERCISE
s !DJUSTABLE 2ESET 2ATIO
s 7ARM 7EATHER 3HUTDOWN
s ,ARGE ,#$ $ISPLAY
s /UTDOOR AND  3TRAP ON 3ENSORS INCLUDED

0ERFORMANCE $ATA

4HE 8 0UMP "LOCK 80" IS A COMPLETE MIXING SYSTEM WITH AN ATTACHED BRAZED PLATE COUNTERFLOW
STYLE HEAT EXCHANGER FOR SYSTEM ISOLATION )NTEGRAL TO THE UNIT IS A VARIABLE SPEED HEAT SOURCE CIRCULATOR
CONSTANT SPEED SYSTEM CIRCULATOR AND THE ELECTRONICS TO DRIVE IT ALL 4HE 80" CAN BE SET UP TO OPERATE
AS AN OUTDOOR RESET CONTROL A SETPOINT CONTROL OR A DELTA 4 LIMITING CONTROL4HIS UNPARALLELED FLEXIBILITY
WITHIN A SINGLE UNIT CREATES A PUMPING AND CONTROL PACKAGE THAT CAN BE USED IN SYSTEMS COMBINING ANY
STYLE HEAT SOURCE BOILER WATER HEATER ETC WITH ANY STYLE HEAT DELIVERY METHOD OR SYSTEM CONDITION
RADIANT TUBING GLYCOL BASED SNOWMELT OPEN SYSTEM ETC  7ITH JUST  PIPING CONNECTIONS NEEDED THE
80" GREATLY REDUCES THE TIME AND SPACE REQUIRED FOR INSTALLATION





 



 





 


 !

 



 

!


!


  
 

  
 



  

"


 

4HE FEATURES OF THE 8 0UMP "LOCK MAKES IT EASY AND COST EFFECTIVE TO INCLUDE A HYDRONIC BASED RADIANT
FLOOR WARMING SYSTEM IN ANY KITCHEN AND BATH REMODEL PROJECT ESPECIALLY IN HOMES WHICH HAVE AN AIR BASED
HEATING SYSTEM4HE 80" ALSO MAKES THE PERFECT COMPANION FOR BASEMENT hRADIANT READYv PACKAGES JOBS
WHERE SPACE IS AT A PREMIUM AND SMALL SNOWMELT AREAS SUCH AS HANDICAP ACCESSIBLE BUILDING ENTRANCES

/PERATION

(OT WATER FROM THE HEAT SOURCE SUCH AS A BOILER ENTERS THE 8 0UMP "LOCKS INTEGRAL HEAT EXCHANGER
AT PORT ! AND EXISTS AT !  4HE VARIABLE SPEED CIRCULATOR CONTROLS THE SPEED OF THE WATER FLOWING
THROUGH THE ! SIDE OF THE HEAT EXCHANGER TO SATISFY THE HEAT TRANSFER REQUIREMENTS BETWEEN THE ! SIDE
OF THE HEAT EXCHANGER AND THE " SYSTEM SIDE 4HE HEAT EXCHANGER IS A COUNTERFLOW STYLE SO SYSTEM
WATER ENTERS AT PORT " AND EXITS AT PORT "  ! CONSTANT SPEED
"
CIRCULATOR MOVES THE WATER AROUND THE " SYSTEM SIDE )N
!
CERTAIN APPLICATIONS SUCH AS SNOWMELT THE SYSTEM PUMP MOTOR
" CAN BE SWITCHED WITH THE VARIABLE SPEED MOTOR IN ORDER TO
PROTECT THE HEAT EXCHANGER FROM FREEZING UP BY ENSURING
!
CONSTANT FLOW ON THE HEAT SOURCE SIDE

3IZING AND 0IPING

&LOW 2ANGE  n  '0(EAD 2ANGE  n  &EET
-INIMUM &LUID 4EMPERATURE ƒ& ƒ#
-AXIMUM &LUID 4EMPERATURE ª& ƒ#
-AXIMUM 7ORKING 0RESSURE  PSI
#ONNECTION 3IZES v .04
&/2 ).$//2 53% /.,9

4HE 8 0UMP "LOCK CAN HANDLE TRANSFER LOADS OF UP TO APPROXIMATELY
  "45 9OUR CURRENT METHOD OF PIPING VIRTUALLY REMAINS THE
SAME YET COMPLETE SYSTEM ISOLATION IS ACHIEVED 4HE ONLY ADDITION
NEEDS TO BE A SEPARATE EXPANSION TANK AND RELIEF VALVE ON THE SYSTEM
SIDE  OUTDOOR SENSOR  STRAP ON SENSORS AND A LINE CORD ARE
INCLUDED FOR FAST PLUG N PLAY WIRING
$#!
"!

0ERFORMANCE &IELD

#$!
"!

%$ "
# "

$%"
# "

!""$!


"##%"









 




3YSTEM 3IDE
#IRCULATOR


 

$ &
$# $## "!
&"#

!%$" 
$ %"

'!

%!!(
%$!%$$  # "
(#$

%!  %$! # &#

$  $# "!$#!"



%LECTRICAL  7EIGHT $ATA







%


 $#!
#$!



-ODEL 6OLTS (Z 0H !MPS 20-

(EAT 3OURCE
3IDE #IRCULATOR



80" 










  



-OTOR
4YPE











(0


3HIP 7T

 LBS +G

0ERMANENT 3PLIT #APACITOR
)MPEDANCE 0ROTECTED





( 9$2/.)# # /-0/.%.43  3 934%-3

Do it Once. Do it Right.

Taco, Inc., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: (401) 942-2360
Taco (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436

4ACO )NC  #RANSTON 3TREET #RANSTON 2)       &AX   
Visit our website at: www.taco-hvac.com
4ACO #ANADA ,TD  /RDAN $RIVE -ISSISSAUGA /NTARIO ,4 "      &AX   
WWWTACO HVACCOM

Printed in USA
Copyright 2005
TACO, Inc.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1.1-111
About                           : 2bf26d1a-d42f-11d9-ad04-895864b2f99e
Create Date                     : 2005:09:23 13:58:36-04:00
Modify Date                     : 2005:09:23 13:58:39-04:00
Metadata Date                   : 2005:09:23 13:58:39-04:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 14612 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:ab6d10e8-2c5b-11da-9feb-0011247ebd3a
Document ID                     : adobe:docid:indd:317a66ba-252f-11da-b31d-80057f14365d
Rendition Class                 : proof:pdf
Derived From Instance ID        : bc0eb1f6-1a0a-11da-9c13-b178510b783f
Derived From Document ID        : adobe:docid:indd:0797e874-1715-11da-8e5c-a7c406fd07d0
Derived From Version ID         : 1
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:5057a412-23ca-11da-a569-0011247ebd3a, uuid:37A021BA067611DA8DBAAA8852931B3F
Manifest Reference Document ID  : uuid:501ac77d-23ca-11da-a569-0011247ebd3a, uuid:37A021B9067611DA8DBAAA8852931B3F
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 1
Creator                         : Adobe InDesign CS2 (4.0)
EXIF Metadata provided by EXIF.tools

Navigation menu