155 1 Zoeller 267 Brochure User Manual
161 1 Zoeller 267 Brochure 161_1_Zoeller 267 Brochure
182 1 Zoeller 267 Product Brochure 182_1_Zoeller 267 Product Brochure
153 1 Zoeller 267 Brochure 153_1_Zoeller 267 Brochure 153_1_Zoeller 267 Brochure pdf pumpproducts
User Manual: Pump 155 1 Zoeller 267 Brochure
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
SECTION: 2.30.020 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. FM0390 1011 Supersedes 0311 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 COMPARE THESE FEATURES • Float-operated, submersible (NEMA 6) 2-pole mechanical switch • Durable cast construction, ASTM Class 25 cast iron, switch case, and pump housing • Cast iron base on 267, 268 • Engineered Plastic base on 266 • Non-Clogging Vortex Impeller Design Engineered plastic impeller with metal inserts on models 266, 267 & 268 (1 PH) Model 267 available with cast iron impeller option (Cast iron impeller standard on 3 PH models.) • Not effected by materials normally found in drainage and sewage sumps • Stainless steel screws, bolts, handle, guard, and arm and seal assembly • UL Listed 3-wire neoprene cord and plug 10 ft. cord standard for automatic 15 ft. cord standard for nonautomatic • Square Ring & Gasket - Neoprene • Motor - 266/267/268 Series - ½ HP 60 Hz, 1725 RPM, oil-filled, hermetically sealed, automatic reset thermal overload protected (1 PH only) • Oil lubricated bearings • Carbon and ceramic shaft seal • Passes 2” spherical solids • 2” NPT discharge • Model 268 contains combination 2” NPT female and 3” NPT male discharge • On point - 12”; Off point - 4” (Automatic units) • Corrosion resistant powder coated epoxy finish 266 - 267 - 268 Series (For Pump Prefix Identification see News & Views 0052) “WASTE-MATE” SUBMERSIBLE SEWAGE/*EFFLUENT PUMP OR DEWATERING PUMP 2” NPT DISCHARGE UL ** Automatic “267” R Tested to UL Standard UL778 R Certified to CSA Standard C22.2 No.108 • • • • • • FEATURES AVAILABLE Automatic Nonautomatic (for variable level systems) 2” NPT Discharge (2” & 3” Model 268) ½ HP, 1 Ph, 115V, 200-208V, or 230V Passes 2” Spherical Solids BN and BE267 pumps available packaged with a Piggyback Variable Level Float Switch • ½ HP, 3 Ph, 200-208V, 230V, or 460V ALL MODELS ARE COMPLETELY SUBMERSIBLE HERMETICALLY SEALED Automatic “268” Watertight - dust tight. Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with nonautomatic pumps. * May be used in those states where codes do not restrict solids size in effluent systems. ** See back page for UL & CSA listings. visit our web site: www.zoeller.com Nonautomatic “267” for variable level systems © Copyright 2011 Zoeller Co. All rights reserved. HEAD CAPACITY CURVE 266/267/268 MODELS FEET METERS TOTAL DYNAMIC HEAD/FLOW PER MINUTE SEWAGE AND DEWATERING TOTAL DYNAMIC HEAD 25 6 20 15 MODEL 266/267/268 Meters Feet 5 1.5 10 3.0 15 4.6 20 6.1 Shut-off Head: Liters Gal. 128 484 89 337 50 189 10 38 21.5 ft.(6.6m) 4 013225B 10 2 5 SK375 0 20 40 60 80 100 120 140 MODEL GALLONS LITERS 0 80 160 240 320 360 400 FLOW PER MINUTE A B C D E F G H 266 4-3/4 8-5/16 6-13/32 4-3/4 6-15/32 2” NPT 14-1/32 6-3/32 267 4-3/4 8-5/16 6-13/32 4-3/4 6-15/32 2” NPT 14-9/32 6-11/32 268 4-3/4 8-13/32 6-13/32 4-3/4 6-15/32 2”/3” NPT 14-1/32 8-13/32 013225A CONSULT FACTORY FOR SPECIAL APPLICATIONS Model M266 ** BN266 N266 D266 E266 ** BE266 * H266 * I266 * J266 * F266 * G266 Model M267 ** BN267 ** * * * * * N267 D267 E267 BE267 H267 I267 J267 F267 G267 Model M268 ** BN268 N268 D268 E268 ** BE268 * H268 * I268 * J268 * F268 * G268 266 MODELS Volts-Ph 115 115 115 230 230 230 200-208 200-208 200-208 230 460 1 1 1 1 1 1 1 1 3 3 3 267 MODELS Volts-Ph 115 115 115 230 230 230 200-208 200-208 200-208 230 460 1 1 1 1 1 1 1 1 3 3 3 268 MODELS Volts-Ph 115 115 115 230 230 230 200-208 200-208 200-208 230 460 *No molded plug 1 1 1 1 1 1 1 1 3 3 3 Mode Amps Auto Auto Non Auto Non Auto Auto Non Non Non Non 10.4 10.4 10.4 5.5 5.5 5.5 6.2 6.2 2.6 2.6 1.5 Mode Amps Auto Auto Non Auto Non Auto Auto Non Non Non Non 10.4 10.4 10.4 5.5 5.5 5.5 6.2 6.2 2.6 2.6 1.5 Mode Amps Auto Auto Non Auto Non Auto Auto Non Non Non Non 10.4 10.4 10.4 5.5 5.5 5.5 6.2 6.2 2.6 2.6 1.5 **Single piggyback switch included Control Selection Simplex Duplex 1 ** 2 or 3 1 2 or 3 ** 1 3 3 3 3 4 4 2 or 4 --4 ----4 4 4 4 Control Selection Simplex Duplex 1 ** 2 or 3 1 2 or 3 ** 1 3 3 3 3 4 4 2 or 4 --4 ----4 4 4 4 Control Selection Simplex Duplex 1 ** 2 or 3 1 2 or 3 ** 1 3 3 3 3 4 4 2 or 4 --4 ----4 4 4 4 Listings CSA UL Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y N Listings CSA UL Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y N Listings CSA UL Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y N • Minimum recommended basin size (Small load applications) Simplex - 18” x 30” Duplex - 30” x 36” • High water alarms available Standard All Models 266 - Weight 41 lbs. ½ HP 267 - Weight 47.5 lbs. ½ HP 268 - Weight 51 lbs. ½ HP Caution: Maximum temperature of sewage or dewatering must be limited to 130°F (54°C). For over 130°F (54°C) special quotation required. • For “M” and “D” models, the approximate gallons pumped out per cycle are: Tank Diameter Gallons Pumped 18” Simplex 8 Gallons 24” Simplex 15 Gallons 30” Duplex 22 Gallons 36” Duplex 33 Gallons 48” Duplex 60 Gallons SELECTION GUIDE 1. Integral float operated mechanical switch, no external control required. 2. For automatic use single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477. 3. See FM1228 for correct model of simplex control panel. 4. See FM0712 for correct model of duplex control panel or FM1663 for a residential alternator system. For information on additional Zoeller products refer to catalog on SImplex Panels, FM1596; Piggyback Variable Level Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator, FM0495; Sump/ Sewage Basins, FM0487; Single Phase Alarm Systems, FM0732; Watertight Junctions Boxes, FM1597; and Disconnect & Rail Systems, FM0787. All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. © Copyright 2011 Zoeller Co. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00 Create Date : 2011:10:07 10:45:08-04:00 Metadata Date : 2011:10:07 10:45:13-04:00 Modify Date : 2011:10:07 10:45:13-04:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 14542 bytes, use -b option to extract), (Binary data 10713 bytes, use -b option to extract) Instance ID : uuid:f8e7ba66-fe1c-4adf-b5ee-2d13bdd8c762 Document ID : xmp.did:C41B98E42CE9E01199BBA46BAA5BC91A Original Document ID : adobe:docid:indd:f8d98dfe-59a0-11de-948b-fc40c3d85ce7 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:55A0F7D62CE9E01199BBA46BAA5BC91A Derived From Document ID : adobe:docid:indd:f8d98dfe-59a0-11de-948b-fc40c3d85ce7 Derived From Original Document ID: adobe:docid:indd:f8d98dfe-59a0-11de-948b-fc40c3d85ce7 Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:816401B2FAB4DF119E8D94F42EFDB994, xmp.iid:468B08B2FAB4DF119E8D94F42EFDB994, xmp.iid:CE5F0161FBB4DF119E8D94F42EFDB994, xmp.iid:4E240661FBB4DF119E8D94F42EFDB994, xmp.iid:B46836BDFBB4DF119E8D94F42EFDB994, xmp.iid:342D3BBDFBB4DF119E8D94F42EFDB994, xmp.iid:3A43A130FDB4DF119E8D94F42EFDB994, xmp.iid:BA07A630FDB4DF119E8D94F42EFDB994, xmp.iid:5DEAF29EFDB4DF119E8D94F42EFDB994, xmp.iid:DDAEF79EFDB4DF119E8D94F42EFDB994, xmp.iid:DEAEF79EFDB4DF119E8D94F42EFDB994, xmp.iid:DFAEF79EFDB4DF119E8D94F42EFDB994, xmp.iid:E0AEF79EFDB4DF119E8D94F42EFDB994, xmp.iid:E1AEF79EFDB4DF119E8D94F42EFDB994, xmp.iid:2462142FFEB4DF119E8D94F42EFDB994, xmp.iid:2562142FFEB4DF119E8D94F42EFDB994, xmp.iid:2662142FFEB4DF119E8D94F42EFDB994, xmp.iid:2762142FFEB4DF119E8D94F42EFDB994, xmp.iid:ACBDE3B8524EE011B20882E0459729C1, xmp.iid:ADBDE3B8524EE011B20882E0459729C1, xmp.iid:8343FF00544EE011B20882E0459729C1, xmp.iid:0D7E8B006C59E0118759C77765388321, xmp.iid:2836F7EF6C59E0118759C77765388321, xmp.iid:E6879AB976A2E011813992FE01D2226E, xmp.iid:55A0F7D62CE9E01199BBA46BAA5BC91A, xmp.iid:C41B98E42CE9E01199BBA46BAA5BC91A, xmp.iid:6A7855542EE9E01199BBA46BAA5BC91A, xmp.iid:0027C1072FE9E01199BBA46BAA5BC91A, xmp.iid:A5D25D4A31E9E01199BBA46BAA5BC91A, xmp.iid:7621725231E9E01199BBA46BAA5BC91A, xmp.iid:67E0AEFE3DE9E01199BBA46BAA5BC91A, xmp.iid:DCDDE80B3EE9E01199BBA46BAA5BC91A, xmp.iid:CC01A74F3FE9E01199BBA46BAA5BC91A, xmp.iid:8BEBCDE5F2F0E011886C95398ABE9F40 History When : 2010:08:31 08:24:26-04:00, 2010:08:31 08:24:26-04:00, 2010:08:31 08:29:20-04:00, 2010:08:31 08:29:20-04:00, 2010:08:31 08:31:54-04:00, 2010:08:31 08:31:54-04:00, 2010:08:31 08:42:18-04:00, 2010:08:31 08:42:18-04:00, 2010:08:31 08:45:23-04:00, 2010:08:31 08:45:23-04:00, 2010:08:31 08:46:17-04:00, 2010:08:31 08:46:17-04:00, 2010:08:31 08:47:37-04:00, 2010:08:31 08:47:37-04:00, 2010:08:31 08:49:24-04:00, 2010:08:31 08:49:24-04:00, 2010:08:31 08:52:14-04:00, 2010:08:31 08:52:14-04:00, 2011:03:14 11:50:01-04:00, 2011:03:14 11:50:01-04:00, 2011:03:14 11:59:12-04:00, 2011:03:28 14:48:42-04:00, 2011:03:28 14:55:23-04:00, 2011:06:29 13:39:22-04:00, 2011:09:27 13:19:44-04:00, 2011:09:27 13:19:44-04:00, 2011:09:27 13:30:01-04:00, 2011:09:27 13:35:02-04:00, 2011:09:27 13:51:13-04:00, 2011:09:27 13:51:26-04:00, 2011:09:27 15:22:09-04:00, 2011:09:27 15:22:31-04:00, 2011:09:27 15:31:36-04:00, 2011:10:07 10:44:45-04:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Doc Change Count : 83 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 2 Creator : Adobe InDesign CS5 (7.0.4)EXIF Metadata provided by EXIF.tools