SECTION:4.10.025
FM1705
1011
Supersedes
0610
Control Panel Features:
• Intrinsically safe relays.
• NEMA 4X enclosure.
• Top mounted alarm light.
• Hands-Off-Auto Toggle Switch for each
pump.
• UL Listed.
• Alarm horn with silence switch.
• Magnetic motor contactor.
• Lockable Latch.
• Auxiliary Dry Contact/High Water Alarm.
• Circuit breaker pump disconnect.
• 3or4variableoatswitchcontroloperation
(see FM0526).
• 2 year warranty.
• The use of off-the-shelf components provide for
relativelyeasyeldmaintenanceandrepair.
• Green pump run pilot light for each pump.
• Seal fail indicator light(s).
• Thermal cutouts for 3 Phase.
• Duplex only - Lead/Lag alternating circuit.
• For additional information refer to FM1596
(Simplex), FM0486 (Duplex), or consult the
factory representative.
CONTROL PANELS FOR EXPLOSION PROOF PUMPS
SIMPLEX AND DUPLEX WITH INTRINSICALLY SAFE RELAYS
Product information presented here
reectsconditionsattimeofpublication.
Consult factory regarding discrepancies
or inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
Duplex Intrinsically Safe Panel
May not be exactly as illustrated
R
L
Simplex Intrinsically Safe Panel
Theseintrinsicallysafecontrolpanelsareusedonpumpapplicationsdenedasahazardousdutylocation.Liftstations
insomeregionsfallunderthisclassication.Theintrinsicallysafepanel,inconjunctionwithanexplosionproofpump,will
provide a system that will not allow ignition of the explosive gases. The purpose of the control panel is to cycle a pump
automatically. Each panel comes standard with pump run light(s), a high water audible and visual alarm, seal fail indicator(s),
and a UL Listing. All panels come standard with a NEMA 4X rating for indoor or outdoor use.
ThesepanelsMUSTNOTbeinthespaceclassiedasneedingexplosionproofequipment.Specialttingsthateither
preventthepassageofhotgases,inthecaseofanexplosioninaClassIareaorthepassageofcombustibledust,bers,
oryingsinaClassIIorIIIarea(NEC501-5and502-5),arerequired.Aqualiedelectricianmustinstallallelectrical
systems.NationalElectricalCode(NEC)Articles500through503explainindetailtherequirementsfortheinstallationof
wiringorelectricalequipmentinhazardouslocations.Thesearticlesalongwithotherapplicableregulations,localgoverning
inspectionauthorities,insurancerepresentatives,andqualiedengineering/technicalassistanceshouldbeyourguidesto
theinstallationofwiringorelectricalequipmentinanyhazardousorpotentiallyhazardouslocation.
© Copyright 2011 Zoeller Co. All rights reserved.
R
L
Tested to UL Standard UL 508
Tested to UL Standard UL 508
SIMPLEX / DUPLEX PANELS RECOMMENDED FOR PUMPS WITH EXPLOSION PROOF MOTORS
PUMP DATA CONTROL PANEL PUMP DATA CONTROL PANEL
© Copyright 2011 Zoeller Co. All rights reserved.
MODEL # VOLT PHASE AMPS HP SIMPLEX DUPLEX
NX161 115 1 15.5 0.5 10-1294 10-1233
EX161 230 1 7.5 0.5 10-1242 10-1297
IX161 200-208 1 8.8 0.5 10-1242 10-1297
JX161 200-208 3 6.4 0.5 10-1222 10-1228
FX161 230 3 5.2 0.5 10-1218 10-1224
GX161 460 3 2.9 0.5 10-1219 10-1225
BAX161 575 3 2.4 0.5 10-1248 10-1254
NX163 115 1 15.0 0.5 10-1242 10-1297
EX163 230 1 7.5 0.5 10-1242 10-1297
IX163 200-208 1 8.5 0.5 10-1242 10-1297
JX163 200-208 3 6.0 0.5 10-1218 10-1224
FX163 230 3 4.8 0.5 10-1218 10-1224
GX163 460 3 2.9 0.5 10-1219 10-1225
BAX163 575 3 2.4 0.5 10-1248 10-1254
EX165 230 1 10.2 1.0 10-1242 10-1297
IX165 200-208 1 12.6 1.0 10-1242 10-1297
JX165 200-208 3 7.5 1.0 10-1222 10-1228
FX165 230 3 7.4 1.0 10-1222 10-1228
GX165 460 3 3.7 1.0 10-1219 10-1226
EX185 230 1 9.8 1.0 10-1242 10-1297
IX185 200-208 1 11.5 1.0 10-1242 10-1297
JX185 200-208 3 7.5 1.0 10-1222 10-1228
FX185 230 3 7.4 1.0 10-1222 10-1228
GX185 460 3 3.7 1.0 10-1219 10-1226
EX186 230 1 13.7 1.5 10-1242 10-1297
FX186 230 3 8.6 1.5 10-1222 10-1228
GX186 460 3 4.6 1.5 10-1218 10-1224
EX188 230 1 14.0 1.5 10-1242 10-1297
IX188 200-208 1 16.8 1.5 10-1294 10-1233
JX188 200-208 3 10.3 1.5 10-1229 10-1231
FX188 230 3 8.9 1.5 10-1222 10-1228
GX188 460 3 4.6 1.5 10-1218 10-1224
BAX188 575 3 3.5 1.5 10-1250 10-1256
EX189 230 1 16.6 2.0 10-1294 10-1233
IX189 200-208 1 20.5 2.0 10-1295 10-1235
JX189 200-208 3 13.2 2.0 10-1230 10-1232
FX189 230 3 11.2 2.0 10-1229 10-1231
GX189 460 3 6.0 2.0 10-1218 10-1224
BAX189 575 3 5.8 2.0 10-1252 10-1258
EX191 230 1 14.5 2.0 10-1242 10-1297
NX282 115 1 10.3 0.5 10-1242 10-1297
EX282 230 1 5.0 0.5 10-1241 10-1296
IX282 200-208 1 6.1 0.5 10-1241 10-1296
JX282 200-208 3 3.6 0.5 10-1219 10-1226
FX282 230 3 3.0 0.5 10-1219 10-1225
GX282 460 3 1.7 0.5 10-1562 10-1590
BAX282 575 3 1.4 0.5 10-1247 10-1253
EX284 230 1 8.9 1.0 10-1242 10-1297
IX284 200-208 1 9.3 1.0 10-1242 10-1297
JX284 200-208 3 5.5 1.0 10-1218 10-1224
FX284 230 3 5.0 1.0 10-1218 10-1224
GX284 460 3 2.6 1.0 10-1219 10-1225
BAX284 575 3 2.2 1.0 10-1248 10-1254
NX292 115 1 15.0 0.5 10-1242 10-1297
BAX292 575 3 2.4 0.5 10-1248 10-1254
Standard Enclosure Dimensions
Panel Phase Dimensions
H x W x D (in)
Simplex 1 16 x 14 x 6
Duplex 1 16 x 14 x 6
Simplex 3 16 x 14 x 6
Duplex 3 16 x 14 x 6
MODEL # VOLT PHASE AMPS HP SIMPLEX DUPLEX
EX293 230 1 10.2 1.0 10-1242 10-1297
IX293 200-208 1 12.0 1.0 10-1242 10-1297
JX293 200-208 3 8.2 1.0 10-1222 10-1228
FX293 230 3 7.6 1.0 10-1222 10-1228
GX293 460 3 4.0 1.0 10-1218 10-1224
BAX293 575 3 3.3 1.0 10-1250 10-1256
EX294 230 1 13.7 1.5 10-1242 10-1297
IX294 200-208 1 16.5 1.5 10-1294 10-1233
JX294 200-208 3 10.8 1.5 10-1229 10-1231
FX294 230 3 9.5 1.5 10-1222 10-1228
GX294 460 3 4.8 1.5 10-1218 10-1224
BAX294 575 3 3.8 1.5 10-1250 10-1256
EX295 230 1 16.6 2.0 10-1294 10-1233
IX295 200-208 1 20.5 2.0 10-1295 10-1235
JX295 200-208 3 14.3 2.0 10-1230 10-1232
FX295 230 3 12.2 2.0 10-1229 10-1231
GX295 460 3 6.1 2.0 10-1222 10-1228
BAX295 575 3 4.9 2.0 10-1252 10-1258
EX404 230 1 12.9 3.0 10-1242 10-1297
IX404 200 1 14.4 3.0 10-1242 10-1297
JX404 200 3 13.8 3.0 10-1230 10-1232
FX404 230 3 13.1 3.0 10-1230 10-1232
GX404 460 3 5.2 3.0 10-1218 10-1224
BAX404 575 3 4.1 3.0 10-1252 10-1258
EX405 230 1 19.0 3.0 10-1294 10-1233
IX405 200 1 20.2 3.0 10-1295 10-1235
JX405 200 3 14.8 3.0 10-1230 10-1232
FX405 230 3 12.2 3.0 10-1229 10-1231
GX405 460 3 6.1 3.0 10-1222 10-1228
BAX405 575 3 4.8 3.0 10-1251 10-1257
EX611 230 1 6.9 1.0 10-1559 10-1587
JX611 200 3 4.3 1.0 10-1560 10-1588
FX611 230 3 3.7 1.0 10-1561 10-1589
GX611 460 3 1.9 1.0 10-1562 10-1590
BAX611 575 3 1.6 1.0 10-1563 10-1591
EX621 230 1 8.9 1.5 10-1564 10-1592
JX621 200 3 5.9 1.5 10-1560 10-1588
FX621 230 3 5.1 1.5 10-1560 10-1588
GX621 460 3 2.6 1.5 10-1561 10-1589
BAX621 575 3 2.0 1.5 10-1563 10-1591
EX631 230 1 14.5 2.0 10-1573 10-1601
JX631 200 3 7.8 2.0 10-1565 10-1593
FX631 230 3 6.8 2.0 10-1565 10-1593
GX631 460 3 3.4 2.0 10-1561 10-1589
BAX631 575 3 2.7 2.0 10-1566 10-1594
EX641 230 1 17.0 3.0 10-1567 10-1595
JX641 200 3 11.0 3.0 10-1568 10-1596
FX641 230 3 9.6 3.0 10-1568 10-1596
GX641 460 3 4.8 3.0 10-1560 10-1588
BAX641 575 3 3.9 3.0 10-1566 10-1594
EX651 230 1 28.0 5.0 10-1569 10-1597
JX651 200 3 17.5 5.0 10-1570 10-1598
FX651 230 3 15.2 5.0 10-1571 10-1599
GX651 460 3 7.6 5.0 10-1565 10-1593
BAX651 575 3 6.1 5.0 10-1572 10-1600
JX661 200 3 25.3 7.5 10-1577 10-1605
FX661 230 3 22.0 7.5 10-1575 10-1603
GX661 460 3 11.0 7.5 10-1568 10-1596
BAX661 575 3 9.0 7.5 10-1576 10-1604