17092 2 Zoeller Control Panel Diagram ZM1342 Panels User Manual
17091 2 Zoeller Control Panel Diagram 17091_2_Zoeller Control Panel Diagram
17086 2 Zoeller Control Panel Diagram 17086_2_Zoeller Control Panel Diagram
17088 2 Zoeller Control Panel Diagram 17088_2_Zoeller Control Panel Diagram
17084 3 Zoeller Control Panel Diagram 17084_3_Zoeller Control Panel Diagram
17093 2 Zoeller Control Panel Diagram 17093_2_Zoeller Control Panel Diagram
User Manual: Pump 17092 2 Zoeller Control Panel Diagram
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
SECTION: Z5.00.110 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. ZM1342 0810 Supersedes 0410 ® visit our web site: www.zoeller.com MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1 - 20 BHP COMMERCIAL DUTY EJECTORS, SOLIDS HANDLING AND GRINDER PUMPS Commercial Effluent - Pg. 2 Commercial Sewage - Pg. 3 61 HD Series - Pg. 6 62 HD Series - Pg. 6 Grinder Pumps - Pg. 8 * Standard Options Seal Fail Relay w/ Indication, Thermal Cutout Circuit(s), Intrinsically Safe Relays, Elapsed Time Meter(s), Event Counter(s), Flasher for High Water Alarm Light, Redundant Off, Inner Door, Lightning Arrestor, Anti-Condensation Heater, Manual Alarm Reset Standard Features: 1. NEMA-4X Thermoplastic Enclosure 2. cULus Labeled 3. Input Power Terminal Block 4. Float Switch Terminal Block 5. Ground Lug 6. Control Side Fuses 7. Control On/Off Switch 8. Lockable Hasp 9. HOA Switch(es) 10. IEC Rated Motor Contactor(s) 11. 120 Volt Control Circuit or Transformer 12. Pump Disconnect(s) and Motor Overload Protection (3 Phase, 61HD Series & 71 Series) 13. External High Water Alarm Light 14. Audible High Water Alarm Horn 15. Dry Auxilliary Contacts 16. Alarm Test and Silence Switch (Externally Mounted) 17. Green Pump Run Light(s) 18. Capacitors and Start Relay (Single Phase) 19. Alternating Circuit Board (Duplex) 20. Float Status Indicator Lights 21. Seal Fail Relay(s) w/ Indication Thermal Cut-out Circuit(s) * Standard Options Intrinsically Safe Relays, Elapsed Time Meter(s), Event Counter(s), Flasher for High Water Alarm Light, Redundant Off, Inner Door, Lightning Arrestor, Anti-Condensation Heater, Manual Alarm Reset Standard Features: 1. NEMA-4X Thermoplastic Enclosure 2. cULus Labeled 3. Input Power Terminal Block 4. Float Switch Terminal Block 5. Ground Lug 6. Control Side Fuses 7. Control On/Off Switch 8. Lockable Hasp 9. HOA Switch(es) 10. IEC Rated Motor Contactor(s) 11. 120 Volt Control Circuit or Transformer 12. Pump Circuit Breaker(s) or Motor Overload Protection w/ Disconnect (3 Phase and 61HD Series) 13. External High Water Alarm Light 14. Audible High Water Alarm Horn 15. Dry Auxilliary Contacts 16. Alarm Test and Silence Switch (Externally Mounted) 17. Green Pump Run Light(s) 18. Capacitors and Start Relay (1 Phase 61 HD Series) 19. Alternating Circuit Board (Duplex) 20. Float Status Indicator Lights * Consult Factory for Options Not Listed HAZARDOUS ENVIRONMENT SERIES** (Class 1, Division 1, Group C & D) Commercial Duty Ejectors - Pg. 4 & 5 X61 HD and X62 HD Series - Pg. 7 X71 Series Grinder Pumps - Pg. 8 Standard Features: 1. NEMA-4X Thermoplastic Enclosure 2. cULus Labeled 3. Input Power Terminal Block 4. Float Switch Terminal Block 5. Ground Lug 6. Control Side Fuses 7. Control On/Off Switch 8. Lockable Hasp 9. HOA Switch(es) 10. IEC Rated Motor Contactor(s) 11. 120 Volt Control Circuit or Transformer 12. Pump Circuit Breaker(s) or Motor Overload Protection w/ Disconnect 13. External High Water Alarm Light 14. Audible High Water Alarm Horn 15. Dry Auxilliary Contacts 16. Alarm Test and Silence Switch (Externally Mounted) 17. Green Pump Run Light(s) 18. Capacitors and Start Relay (1 Phase Models) 19. Alternating Circuit Board (Duplex) 20. Float Status Indicator Lights 21. Seal Fail Relay(s) w/ Indication, Thermal Cut-out Circuit(s), Intrinsically Safe Relays * Standard Options Elapsed Time Meter(s), Event Counter(s), Flasher for High Water Alarm Light, Redundant Off, Inner Door, Lightning Arrestor, Anti-Condensation Heater, Manual Alarm Reset ** Control Panel must be wired according to NEC and located outside the hazardous area. TYPICAL DUPLEX CONTROL PANEL 11 15 13 21 21 8 3 1 20 19 16 4 6 5 7 2 9 14 17 © Copyright 2010 Zoeller Co. All rights reserved. 1 12 10 NEMA 4X CONTROL PANELS 1,2 COMMERCIAL DUTY EFFLUENT EJECTORS SINGLE PHASE PUMP DATA SIMPLEX DUPLEX Model Number HP Voltage Phase Full Load Amps Panel Amp Range Part Number *Weight (lbs.) *Dimensions HxWxD Part Number *Weight (lbs.) *Dimensions HxWxD N6161 I6161 E6161 N6163 I6163 E6163 I6165 E6165 I6185 E6185 E6186 I6188 E6188 I6189 E6189 1/2 1/2 1/2 1/2 1/2 1/2 1 1 1 1 1-1/2 1-1/2 1-1/2 2 2 115 200 230 115 200 230 200 230 200 230 230 200 230 200 230 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 15.5 8.8 7.5 15.0 8.5 7.5 12.6 10.2 11.5 9.8 13.7 16.8 14.0 20.5 17.1 15-20 7-15 7-15 15-20 7-15 7-15 7-15 7-15 7-15 7-15 7-15 15-20 7-15 20-30 15-20 10-1038 10-1037 10-1037 10-1038 10-1037 10-1037 10-1037 10-1037 10-1037 10-1037 10-1037 10-1038 10-1037 10-1201 10-1038 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 8" X 8" x 4" 10-1045 10-1044 10-1044 10-1045 10-1044 10-1044 10-1044 10-1044 10-1044 10-1044 10-1044 10-1045 10-1044 10-1046 10-1045 19 20 20 19 20 20 20 20 20 20 20 19 20 19 19 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" THREE PHASE PUMP DATA Model Number HP Voltage Phase J6161 F6161 G6161 BA6161 J6163 F6163 G6163 BA6163 J6165 F6165 G6165 BA6165 J6185 F6185 G6185 BA6185 J6186 F6186 G6186 J6188 F6188 G6188 BA6188 J6189 F6189 G6189 BA6189 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1 1 1 1 1 1 1 1 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 2 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 200 230 460 575 200 230 460 575 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 NOTES: DUPLEX 2,3 SIMPLEX 2,3 Full Load Panel Amp Amps Range 6.4 5.2 2.9 2.4 6.0 4.8 2.9 2.4 7.5 7.4 3.7 3.0 7.5 7.4 3.7 3.3 10.3 9.2 4.6 10.3 8.9 4.6 3.5 13.2 11.2 6.0 5.8 6.0-10.0 4.0-6.3 2.5-4.0 1.6-2.5 6.0-10.0 4.0-6.3 2.5-4.0 1.6-2.5 6.0-10 6.0-10 2.5-4.0 2.5-4.0 6.0-10 6.0-10 2.5-4.0 2.5-4.0 9.0-14.0 6.0-10 4.0-6.3 9.0-14.0 6.0-10 4.0-6.3 2.5-4.0 13.0-18.0 9.0-14.0 6.0-10.0 4.0-6.3 Part Number *Weight (lbs.) *Dimensions HxWxD Part Number *Weight (lbs.) *Dimensions HxWxD 10-1082 10-1080 10-1078 10-1132 10-1082 10-1080 10-1078 10-1132 10-1082 10-1082 10-1078 10-1134 10-1082 10-1082 10-1078 10-1134 10-1083 10-1082 10-1080 10-1083 10-1082 10-1080 10-1134 10-1084 10-1083 10-1082 10-1136 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 12" X 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" X 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12" x 10" x 6" 12” x 10 ”x 6” 12” x 10 ”x 6” 12" x 10" x 6" 12" x 10" x 6" 12” x 10 ”x 6” 12” x 10 ”x 6” 12" x 10" x 6" 12" x 10" x 6" 12” x 10 ”x 6” 12" x 10" x 6" 12" x 10" x 6" 12” x 10 ”x 6” 12” x 10 ”x 6” 12" x 10" x 6" 12" x 10" x 6" 12" X 10" x 6" 12" X 10" x 6" 10-1110 10-1108 10-1106 10-1154 10-1110 10-1108 10-1106 10-1154 10-1110 10-1110 10-1106 10-1156 10-1110 10-1110 10-1106 10-1156 10-1111 10-1110 10-1108 10-1111 10-1110 10-1108 10-1156 10-1112 10-1111 10-1110 10-1158 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 21 20 20 20 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 9" 14" x 12" x 6" 14" x 12" x 6" 14" x 12" x 6" (1) Single phase panels furnished with three (3) float switches with 20' cords. (2) The above listed panels meet our standard configurations as listed. If any standard or nonstandard options are required, consult factory. *Weights and dimensions are approximations and could vary. © Copyright 2010 Zoeller Co. All rights reserved. 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : mikem Create Date : 2013:01:15 14:49:19+05:30 Modify Date : 2013:01:15 14:49:35+05:30 Subject : ZM1342 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:01:15 14:49:35+05:30 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : ZM1342-Control Panels Description : ZM1342 Creator : mikem Document ID : uuid:b8a7a07c-9920-4212-866d-77aec4c5c0d9 Instance ID : uuid:08758c2e-0f49-40cf-b51f-9d2350350784 Producer : Acrobat Distiller 8.2.2 (Windows) Page Count : 2EXIF Metadata provided by EXIF.tools