17092 2 Zoeller Control Panel Diagram ZM1342 Panels User Manual

17091 2 Zoeller Control Panel Diagram 17091_2_Zoeller Control Panel Diagram

17086 2 Zoeller Control Panel Diagram 17086_2_Zoeller Control Panel Diagram

17088 2 Zoeller Control Panel Diagram 17088_2_Zoeller Control Panel Diagram

17084 3 Zoeller Control Panel Diagram 17084_3_Zoeller Control Panel Diagram

17093 2 Zoeller Control Panel Diagram 17093_2_Zoeller Control Panel Diagram

User Manual: Pump 17092 2 Zoeller Control Panel Diagram

Open the PDF directly: View PDF PDF.
Page Count: 2

Download17092 2 Zoeller Control Panel Diagram ZM1342-Control Panels User Manual
Open PDF In BrowserView PDF
SECTION: Z5.00.110

Product information presented
here reflects conditions at time
of publication. Consult factory regarding discrepancies or
inconsistencies.

ZM1342
0810
Supersedes
0410

®

visit our web site:
www.zoeller.com

MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

ZOELLER ENGINEERED PRODUCTS
NEMA 4X SIMPLEX & DUPLEX PANELS
1 - 20 BHP
COMMERCIAL DUTY EJECTORS, SOLIDS HANDLING AND GRINDER PUMPS

† Commercial Effluent - Pg. 2
† Commercial Sewage - Pg. 3
† 61 HD Series - Pg. 6

† 62 HD Series - Pg. 6
† Grinder Pumps - Pg. 8

* Standard Options
Seal Fail Relay w/ Indication, Thermal Cutout Circuit(s),
Intrinsically Safe Relays, Elapsed Time Meter(s), Event
Counter(s), Flasher for High Water Alarm Light, Redundant Off, Inner Door, Lightning Arrestor, Anti-Condensation
Heater, Manual Alarm Reset

Standard Features:
1. NEMA-4X Thermoplastic Enclosure
2. cULus Labeled
3. Input Power Terminal Block
4. Float Switch Terminal Block
5. Ground Lug
6. Control Side Fuses
7. Control On/Off Switch
8. Lockable Hasp
9. HOA Switch(es)
10. IEC Rated Motor Contactor(s)
11. 120 Volt Control Circuit or Transformer
12. Pump Disconnect(s) and Motor Overload
Protection (3 Phase, 61HD Series & 71 Series)
13. External High Water Alarm Light
14. Audible High Water Alarm Horn
15. Dry Auxilliary Contacts
16. Alarm Test and Silence Switch (Externally Mounted)
17. Green Pump Run Light(s)
18. Capacitors and Start Relay (Single Phase)
19. Alternating Circuit Board (Duplex)
20. Float Status Indicator Lights
21. Seal Fail Relay(s) w/ Indication
Thermal Cut-out Circuit(s)
* Standard Options
Intrinsically Safe Relays, Elapsed Time Meter(s), Event
Counter(s), Flasher for High Water Alarm Light, Redundant Off, Inner Door, Lightning Arrestor, Anti-Condensation
Heater, Manual Alarm Reset

Standard Features:
1. NEMA-4X Thermoplastic Enclosure
2. cULus Labeled
3. Input Power Terminal Block
4. Float Switch Terminal Block
5. Ground Lug
6. Control Side Fuses
7. Control On/Off Switch
8. Lockable Hasp
9. HOA Switch(es)
10. IEC Rated Motor Contactor(s)
11. 120 Volt Control Circuit or Transformer
12. Pump Circuit Breaker(s) or Motor Overload
Protection w/ Disconnect (3 Phase and 61HD Series)
13. External High Water Alarm Light
14. Audible High Water Alarm Horn
15. Dry Auxilliary Contacts
16. Alarm Test and Silence Switch (Externally Mounted)
17. Green Pump Run Light(s)
18. Capacitors and Start Relay (1 Phase 61 HD Series)
19. Alternating Circuit Board (Duplex)
20. Float Status Indicator Lights

* Consult Factory for Options Not Listed

HAZARDOUS ENVIRONMENT SERIES**
(Class 1, Division 1, Group C & D)

† Commercial Duty Ejectors - Pg. 4 & 5
† X61 HD and X62 HD Series - Pg. 7
† X71 Series Grinder Pumps - Pg. 8
Standard Features:
1. NEMA-4X Thermoplastic Enclosure
2. cULus Labeled
3. Input Power Terminal Block
4. Float Switch Terminal Block
5. Ground Lug
6. Control Side Fuses
7. Control On/Off Switch
8. Lockable Hasp
9. HOA Switch(es)
10. IEC Rated Motor Contactor(s)
11. 120 Volt Control Circuit or Transformer
12. Pump Circuit Breaker(s) or Motor Overload
Protection w/ Disconnect
13. External High Water Alarm Light
14. Audible High Water Alarm Horn
15. Dry Auxilliary Contacts
16. Alarm Test and Silence Switch (Externally Mounted)
17. Green Pump Run Light(s)
18. Capacitors and Start Relay (1 Phase Models)
19. Alternating Circuit Board (Duplex)
20. Float Status Indicator Lights
21. Seal Fail Relay(s) w/ Indication, Thermal Cut-out
Circuit(s), Intrinsically Safe Relays
* Standard Options
Elapsed Time Meter(s), Event Counter(s), Flasher for High
Water Alarm Light, Redundant Off, Inner Door, Lightning
Arrestor, Anti-Condensation Heater, Manual Alarm Reset
** Control Panel must be wired according to NEC and
located outside the hazardous area.

TYPICAL DUPLEX CONTROL PANEL
11

15

13
21

21

8
3

1

20

19
16

4
6

5

7
2

9

14

17

© Copyright 2010 Zoeller Co. All rights reserved.
1

12
10

NEMA 4X CONTROL PANELS 1,2
COMMERCIAL DUTY EFFLUENT EJECTORS
SINGLE PHASE
PUMP DATA

SIMPLEX

DUPLEX

Model
Number

HP

Voltage

Phase

Full Load
Amps

Panel Amp
Range

Part
Number

*Weight
(lbs.)

*Dimensions
HxWxD

Part
Number

*Weight
(lbs.)

*Dimensions
HxWxD

N6161
I6161
E6161
N6163
I6163
E6163
I6165
E6165
I6185
E6185
E6186
I6188
E6188
I6189
E6189

1/2
1/2
1/2
1/2
1/2
1/2
1
1
1
1
1-1/2
1-1/2
1-1/2
2
2

115
200
230
115
200
230
200
230
200
230
230
200
230
200
230

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

15.5
8.8
7.5
15.0
8.5
7.5
12.6
10.2
11.5
9.8
13.7
16.8
14.0
20.5
17.1

15-20
7-15
7-15
15-20
7-15
7-15
7-15
7-15
7-15
7-15
7-15
15-20
7-15
20-30
15-20

10-1038
10-1037
10-1037
10-1038
10-1037
10-1037
10-1037
10-1037
10-1037
10-1037
10-1037
10-1038
10-1037
10-1201
10-1038

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"
8" X 8" x 4"

10-1045
10-1044
10-1044
10-1045
10-1044
10-1044
10-1044
10-1044
10-1044
10-1044
10-1044
10-1045
10-1044
10-1046
10-1045

19
20
20
19
20
20
20
20
20
20
20
19
20
19
19

12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"

THREE PHASE
PUMP DATA
Model
Number

HP

Voltage

Phase

J6161
F6161
G6161
BA6161
J6163
F6163
G6163
BA6163
J6165
F6165
G6165
BA6165
J6185
F6185
G6185
BA6185
J6186
F6186
G6186
J6188
F6188
G6188
BA6188
J6189
F6189
G6189
BA6189

1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1
1
1
1
1
1
1
1
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
2
2
2

200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
575
200
230
460
200
230
460
575
200
230
460
575

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

NOTES:

DUPLEX 2,3

SIMPLEX 2,3
Full Load Panel Amp
Amps
Range
6.4
5.2
2.9
2.4
6.0
4.8
2.9
2.4
7.5
7.4
3.7
3.0
7.5
7.4
3.7
3.3
10.3
9.2
4.6
10.3
8.9
4.6
3.5
13.2
11.2
6.0
5.8

6.0-10.0
4.0-6.3
2.5-4.0
1.6-2.5
6.0-10.0
4.0-6.3
2.5-4.0
1.6-2.5
6.0-10
6.0-10
2.5-4.0
2.5-4.0
6.0-10
6.0-10
2.5-4.0
2.5-4.0
9.0-14.0
6.0-10
4.0-6.3
9.0-14.0
6.0-10
4.0-6.3
2.5-4.0
13.0-18.0
9.0-14.0
6.0-10.0
4.0-6.3

Part
Number

*Weight
(lbs.)

*Dimensions
HxWxD

Part
Number

*Weight
(lbs.)

*Dimensions
HxWxD

10-1082
10-1080
10-1078
10-1132
10-1082
10-1080
10-1078
10-1132
10-1082
10-1082
10-1078
10-1134
10-1082
10-1082
10-1078
10-1134
10-1083
10-1082
10-1080
10-1083
10-1082
10-1080
10-1134
10-1084
10-1083
10-1082
10-1136

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

12" X 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" X 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12" x 10" x 6"
12” x 10 ”x 6”
12” x 10 ”x 6”
12" x 10" x 6"
12" x 10" x 6"
12” x 10 ”x 6”
12” x 10 ”x 6”
12" x 10" x 6"
12" x 10" x 6"
12” x 10 ”x 6”
12" x 10" x 6"
12" x 10" x 6"
12” x 10 ”x 6”
12” x 10 ”x 6”
12" x 10" x 6"
12" x 10" x 6"
12" X 10" x 6"
12" X 10" x 6"

10-1110
10-1108
10-1106
10-1154
10-1110
10-1108
10-1106
10-1154
10-1110
10-1110
10-1106
10-1156
10-1110
10-1110
10-1106
10-1156
10-1111
10-1110
10-1108
10-1111
10-1110
10-1108
10-1156
10-1112
10-1111
10-1110
10-1158

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
21
20
20
20

14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 9"
14" x 12" x 6"
14" x 12" x 6"
14" x 12" x 6"

(1) Single phase panels furnished with three (3) float switches with 20' cords.
(2) The above listed panels meet our standard configurations as listed. If any standard or nonstandard options are required, consult factory.
*Weights and dimensions are approximations and could vary.
© Copyright 2010 Zoeller Co. All rights reserved.
2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : mikem
Create Date                     : 2013:01:15 14:49:19+05:30
Modify Date                     : 2013:01:15 14:49:35+05:30
Subject                         : ZM1342
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:01:15 14:49:35+05:30
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : ZM1342-Control Panels
Description                     : ZM1342
Creator                         : mikem
Document ID                     : uuid:b8a7a07c-9920-4212-866d-77aec4c5c0d9
Instance ID                     : uuid:08758c2e-0f49-40cf-b51f-9d2350350784
Producer                        : Acrobat Distiller 8.2.2 (Windows)
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu