MODEL 503
Zoeller’s Home Guard® Max is a high capacity, high efciency water
powered back-up system. With no electricity or batteries required, the
Home Guard® Max takes over seamlessly when your primary sump
system fails. The Home Guard® Max comes fully assembled for fast,
easy and trouble-free installations, and its small footprint allows for
installation in even the smallest sump pits. With superior performance
and discharge capacity, it uses less water and costs less to operate.
The Home Guard® Max, installed as a back-up system, does not use
any water unless the primary system malfunctions or in the case of
power failure. Water ow is required only when the Home Guard® Max
is operating. This product is not intended for use as a primary water
removal unit.
FEATURES
NEW Low Prole pumps now available 7” shorter than standard model.
No electricity required.
Works during power failures
No battery to charge.
On guard 24 hours a day
Helps eliminate ooding in basements
Can be used with any existing brand of sump pump
Comes 100% pre-assembled
Small footprint - works in 18” x 22” pit
¾” Inlet Piping Connection
1½” Discharge Piping connection
Efcient water usage
Removes up to 2 gallons per gallon used
High capacity, high head
Municipal/city water pressure powered system
Includes push-to-connect supply tting (eld installed)
Engineered for trouble-free operation
Non-corrosive materials
PVC construction
Performs at operating pressures from 20 to 80 psi
Corrosion-resistant stainless steel oat rod for maximum dependability
Water Powered Emergency Backup
Sump Pump System

®
Manufactured by Zoeller Pump Company
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
Your Peace of Mind is Our Top Priority
®
visit our web site:
www.zoeller.com
Primary sump pump not included.
COMPLIES WITH
ASME A112.3.4
UPC
®
Also available with
Audible Alarm # 10-2613
NEW Low
Prole pumps
now available.
7” shorter than
standard model.
© Copyright 2012 Zoeller Co. All rights reserved.
018586
TOTAL DYNAMIC HEAD
FLOW PER MINUTE
15
LITERS 0
GALLONS
20 40
5 10
0
2
5
25
8060
20
PUMP PERFORMANCE
CURVE
MODEL 503
FEET
METERS
4
10
15
6
45
30
25
20
40
35
8
10
12
14
20 PSI
40 PSI
60 PSI
80 PSI
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
DEWATERING ONLY
Manufactured by Zoeller Pump Company
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
®

®
Pump capacity varies due to: Inlet Water Pressure, Working Water Pressure,
Discharge Elevation, Number of Pipe Fittings, Inlet and Outlet Pipe Size, Fluid
Viscosity, Degree of Water Clarity, Water Temperature. The ow rates in the chart are
approximate values.
NOTE: Some districts may require a reduced pressure principle backow preventer
per ASSE Standards 1013. Check Local Codes.
Typical Installation with Submersible Pump
and Separate Discharge Pipe
ON LEVEL
PRIMARY PUMP
FLOAT
ON/OFF
PUMP
SUBMERSIBLE
CHECK VALVES
ABOVE SUCTION SCREEN
OFF LEVEL MUST BE
COUPLINGS
PLUG
3-PRONG
AND ABOVE PRIMARY
PUMP ON LEVEL
BY TESTING. SEE INSTRUCTIONS.
ON LEVEL TO BE DETERMINED
INCOMING WATER
SUPPLY LINE
6" MIN.
BACK FLOW PREVENTER
AND FILTER
(SUPPLIED BY OTHERS)
(SUPPLIED BY OTHERS)
ALARM MAY BE SET TO SOUND PRIOR
TO BACKUP PUMP TURNING ON.
THIS WILL WARN OF MAIN PUMP FAILURE.
IF DESIRED, THE ALARM CAN BE SET TO
SOUND WHEN BACKUP PUMP ACTIVATES.
THIS WILL WARN THAT BACKUP PUMP IS
ON OR HAS FAILED.
(OPTIONAL ALARM)
INSTALL DEDICATED SHUT-OFF
VALVE WITHIN 6FT. (1.8M)
OF HOMEGUARD MAX.
"A-PAK" ALARM SYSTEM
Note: Replace battery every 12 months
INDOOR ALARM SYSTEM 120VAC
TEST
SILENCE
R
WARNING:
ELECTRICAL SHOCK
HAZARD
FAILURE TO DISCONNECT ALL
POWER BEFORE SERVICING
COULD RESULT IN INJURY OR DEATH.
LR54245
LISTED
288X
POWER ON
ALARM
10-1494
R
LOUISVILLE, KY
R
R
PIPING ASSEMBLY
SK2721