18260 1 Little Giant 513286 Submittal User Manual

User Manual: Pump 18260 1 Little Giant 513286 Submittal

Open the PDF directly: View PDF PDF.
Page Count: 2

Download18260 1 Little Giant 513286 Submittal User Manual
Open PDF In BrowserView PDF
Control/Alarm Systems

3 Phase Simplex Alarm System & Pump Control
Applications
n
n
n
n

Lift pump chambers
Sump pump basins
Holding tanks
Sewage and water removal systems

Features
Controls the pump and warns of high liquid levels
Easy to install
Thermoplastic enclosure
HOA switch allows for “Hand” (manual), “Off” or
“Automatic” operation
n Alarm ON/OFF switch controls power to the float circuitry; this and the pump HOA switch provide
an additional safety feature when servicing
n Entire unit UL listed and tested by UL to CSA standards
n
n
n
n

Specifications
n NEMA 4X indoor/outdoor waterproof thermoplastic
enclosure
n Non-corrosive plastic floats for use in liquids up to 140°F
n Sensor float cables — 18 gauge, 2 conductor (UL, CSA)
SJOW, WATER RESISTANT (CPE)

General Description

The Simplex Alarm System/Pump Control provides residential and commercial customers with a reliable means of
controlling a simplex (one pump) system in a water or sewage installation. The system consists of a single control
panel and three easily installed sensor floats.

Control Panel Exterior

The non-corrosive, indoor and/or outdoor enclosure comes pre-assembled. The panel exterior features a large red alarm
beacon and 83 to 85 dB audible alarm horn. Exterior alarm Test/Normal/Silence Switch allows horn and light to be tested
or horn to be silenced in an alarm condition. Horn automatically resets once alarm condition is cleared.

Control Panel Interior

The panel interior consists of a heavy-duty motor contactor and printed circuit board controller. Handy HOA switch
allows for either “Hand” (manual), “Off” or “Automatic” pump operation. A control switch turns off power to the
float circuitry. The control switch and the HOA switch may be turned off to provide an additional safety feature when
servicing. These switches are located inside the panel to protect against activation by unauthorized personnel. A multitap transformer provides 120V control voltage. Motor protective switch provide adjustable overload protection, short
circuit protection and pump disconnect. Green “Pump Run” indicator light, alarm fuses, a control fuse and alarm and
control power indicators all mounted on circuit board. Easy-to-follow wiring diagram and terminal strip provide for
simple installation.

3 Phase Simplex Alarm System & Pump Control

Specifications
Model
No.
3121W151H17A

Item
No.
513282

Volts
208/240/480

Hertz
60

Phase
3

F.L.A.
2.8 - 4.0

Dimensions
H x L x W (in.)
15.5 x 11.4 x 7.3

Weight
(lb.)
21

3121W181H17A

513284

208/240/480

60

3121H221H17A

513286

208/240/480

60

3

5.5 - 8.0

15.5 x 11.4 x 7.3

21

3

11.0 - 16.0

15.5 x 11.4 x 7.3

21

General Installation Instructions

Typical Installation

WARNING: Turn off power source before installing or adjusting this device.
Failure to turn off power could result in serious or fatal electrical shock.

1. Determine the mounting location for the control panel. Liquid-tight
connectors should be used on all cables entering panel. Conduit
connectors, if used, must be sealed.
2. Check local codes and the schematic for power circuit requirements.
On the control panel, determine the “power in” location (from the
building power supply). CAUTION: BE SURE THE POWER
SUPPLY VOLTAGE AND PHASE ARE THE SAME AS THE
PUMP MOTORS BEING INSTALLED.
3. Determine the location on the control panel for the pump power
cables and float switch cables. Drill holes to fit the type of cable fittings to be used.
4. Attach floats as shown in Typical Installation drawing.
5. Following step-by-step instructions and wiring diagram included
with panel, complete connections of all cables.
6. Follow “Manual Testing” procedure in instruction manual.
NOTE: Little Giant Pump Company cannot be responsible for damages
caused by faulty or negligent installation of this control. We recommend
that you engage the services of a competent plumber, electrician, or qualified service person to install this product in accordance with national and
local electrical codes.
ACCESSORIES: Some installations may require a moisture-free junction
box to house electrical connections. Model JB70 Junction Boxes are
recommended. These are available with liquid-tight connectors. The liquidtight connectors are also available separately.
PO Box 12010 • Oklahoma City, OK 73157
Phone: 800.701.7894 • Fax: 800.701.8046
E-mail: customerservice@littlegiant.com

www.LittleGiantPump.com

Form 995220 — 03/2003



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1.1-111
About                           : 220be451-7ef4-11db-993a-830ff8b833ee
Create Date                     : 2007:02:02 14:29:15-06:00
Metadata Date                   : 2007:02:02 14:29:19-06:00
Modify Date                     : 2007:02:02 14:29:19-06:00
Creator Tool                    : Adobe InDesign CS2 (4.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9931 bytes, use -b option to extract)
Document ID                     : adobe:docid:indd:3882c128-7eed-11db-993a-830ff8b833ee
Instance ID                     : uuid:cc7bfe5d-9532-4503-a88f-6ac748f71cf2
Rendition Class                 : proof:pdf
Derived From Instance ID        : 8811b018-6dde-11db-8919-bf300d2dac6b
Derived From Document ID        : adobe:docid:indd:f38c451e-6ddb-11db-8919-bf300d2dac6b
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 600.00, 72.00
Manifest Placed Y Resolution    : 72.00, 600.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:074F599B488CDB1181A0C9D6DB7C5767, uuid:074F599B488CDB1181A0C9D6DB7C5767
Manifest Reference Document ID  : uuid:064F599B488CDB1181A0C9D6DB7C5767, adobe:docid:photoshop:e581576b-7ef0-11db-bf21-ee43b89da1cf, uuid:064F599B488CDB1181A0C9D6DB7C5767
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS2 (4.0)
EXIF Metadata provided by EXIF.tools

Navigation menu