SECTION: 3.10.012

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.

FM2485
0310
Supersedes
0108
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:
www.zoeller.com

PREASSEMBLED 24" x 24" SEWAGE SYSTEMS
Complete and Job-Ready for Fast Installation!

912 SEWAGE SYSTEMS INCLUDE:
•
•
•
•

(1) 2" solids sewage ejector
(1) 24" x 24" poly molded basin
(1) PSF cover with 2V2D
Internal 2" PVC discharge pipe

PUMP FEATURES:
•
•
•
•
•
•

Cast iron construction (264/266)
Thermoplastic construction (211)
Automatic or piggyback configuration available
Full 2" solids capacity
Thermal overload protection
Non-clogging vortex impeller

BASIN FEATURES:
• 24" depth for easier installation in troublesome
areas
• 41 gallon capacity (exceeds 18 x 30)
• 25 gallon capacity below 4" inlet
• Vertical support ribs help eliminate stuck float
switches
• Anti-flotation device helps to eliminate basin from
“floating”
• 360° molded handle (acts as secondary AFD)
• (1) 4" pre-drilled inlet (flex-coupling provided by
others)
• (7) additional flat areas for inlet installation (field
drilled)
• Molded torque stops for added pump support
• One-piece molded PSF cover with integrated
molded foam seal
• Ribbed reinforced cover to provide additional
strength and stability
• Threaded 2" vent and 2" discharge piping
connections
• Stainless steel cover bolts and hardware
• High water alarm available on certain packages
• Stackable for storage/shipping

912-0116 Shown

© Copyright 2010 Zoeller Co. All rights reserved.

FEET

METERS

TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
SEWAGE AND DEWATERING

PUMP PERFORMANCE CURVE
211/264/266 MODELS

TOTAL DYNAMIC HEAD

25

6

20

15
4

MODELS

211

264

266

Feet
Meters
5
1.5
10
3.1
15
4.6
20
6.1
Shut-off Head:

Gal.
Liters
310
82
201
53
121
32
19.5 ft.(5.9m)

Gal.
Liters
341
90
227
60
23
87
18 ft.(5.5m)

Gal.
Liters
128
484
337
89
189
50
38
10
21.5 ft.(6.6m)

10
266
264

2

211

5

0

26 1/2

GALLONS
LITERS

0

20

40

60

80

160
240
320
FLOW PER MINUTE

80

100
360

120

140

400
009969

PUMP SPECIFICATIONS:
•
•
•
•

0.4 HP (211/264) or 1/2 HP (266) available
115 Volts
2" NPT discharge with 2" solids capacity
Refer to FM1784 (211), FM1495 (264) or
FM0390 (266) for additional specifications

28

8

BASIN SPECIFICATIONS:
•
•
•
•
•

Poly molded basin with PSF cover
41 gallon capacity (25 gallons below inlet)
(1) 4" inlet (predrilled, coupling by others)
Integral foam seal
Stainless steel bolt kit

25 5/8

SK2694

Part Number

Pump

Description

912-0112

M211

Automatic 211 - Poly Molded Basin w/ 2V2D PSF Simplex Cover

50

Automatic 211 - Poly Molded Basin w/ 2V2D PSF Simplex Cover includes (1) 10-1494 Indoor Alarm

54

Piggyback Float 211 - Poly Molded Basin w/ 2V2D PSF Simplex Cover

50

Piggyback Float 211 - Poly Molded Basin w/ 2V2D PSF Simplex Cover includes (1) 10-1494 Indoor Alarm

54

912-1112

"

912-0113

BN211

912-1113

"

912-0114

M264

912-1114

"

912-0115

BN264

912-1115

"

912-0116

M266

912-1116

"

912-0117

BN266

912-1117

"

Weight (lbs)

Automatic 264 - Poly Molded Basin w/ 2V2D PSF Simplex Cover

73

Automatic 264 - Poly Molded Basin w/ 2V2D PSF Simplex Cover includes (1) 10-1494 Indoor Alarm

75

Piggyback Float 264 - Poly Molded Basin w/ 2V2D PSF Simplex Cover

73

Piggyback Float 264 - Poly Molded Basin w/ 2V2D PSF Simplex Cover includes (1) 10-1494 Indoor Alarm

75

Automatic 266 - Poly Molded Basin w/ 2V2D PSF Simplex Cover

76

Automatic 266 - Poly Molded Basin w/ 2V2D PSF Simplex Cover includes (1) 10-1494 Indoor Alarm

78

Piggyback Float 266 - Poly Molded Basin w/ 2V2D PSF Simplex Cover

76

Piggyback Float 266 - Poly Molded Basin w/ 2V2D PSF Simplex Cover includes (1) 10-1494 Indoor Alarm

78

JOB READY FOR EASY INSTALLATION

TO REDUCE THE RISK OF ELECTRICAL SHOCK A PROPERLY GROUNDED RECEPTACLE OF GROUNDING TYPE SHALL BE INSTALLED AND
PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI) IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND LOCAL CODES. DO NOT REMOVE
GROUND PIN FROM PLUG.

RESERVE POWERED DESIGN

For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.
© Copyright 2010 Zoeller Co. All rights reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Producer                        : Acrobat Distiller 8.2.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2010:03:23 12:03:58-04:00
Create Date                     : 2010:03:23 12:02:48-04:00
Metadata Date                   : 2010:03:23 12:03:58-04:00
Format                          : application/pdf
Title                           : fm2485-Preassembled 24" X 24" Sewage Systems
Creator                         : mikem
Description                     : FM2485
Document ID                     : uuid:478b9d8a-4238-47a5-bb69-e0396168c1db
Instance ID                     : uuid:5f9e3d8c-9d74-4ef2-9721-5155a4eb5bea
Page Count                      : 2
Subject                         : FM2485
Author                          : mikem
EXIF Metadata provided by EXIF.tools

Navigation menu