213 6 Zoeller N152 Brochure Fm1919 151/152/153 Effluent Series DOSE MATE User Manual
User Manual: Pump 213 6 Zoeller N152 Brochure
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
SECTION: 2.20.047 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. FM1919 0110 Supersedes 1108 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 visit our web site: www.zoeller.com COMPARE THESE FEATURES • Durable cast iron construction 151/152/153 EFFLUENT SERIES • Model 151 comes standard with a glass-filled (For Pump Prefix Identification see News & Views 0052) polypropylene base • Corrosion resistant powder coated epoxy finish • Stainless steel lifting handle • Assembled with stainless steel bolts FOR SEPTIC TANK - LOW PRESSURE PIPE (LPP) • Non-clogging engineered thermoplastic vortex AND ENHANCED FLOW STEP SYSTEMS impeller design • Model 151 - 1/3 HP passes ½" spherical solids SUBMERSIBLE • Model 152 - .4 HP passes ¾" spherical solids 1½" NPT DISCHARGE • Model 153 - 1/2 HP passes ¾" spherical solids • Motor - 60 Hz, 3450 RPM, oil-filled, hermetically sealed, automatic reset thermal overload protected Model N152/N153 High Head • Carbon/Ceramic seals Effluent • Upper sleeve bearing and lower ball bearing running Tested to UL Standard UL778 and Certified to CSA in bath of oil Standard CSA22.2 No. 108 • 20 ft. UL Listed power cord with molded 3-wire plug • 1½" NPT vertical discharge MODELS AVAILABLE • BN and BE standard models include a 20 ft. variable • N151/N152/N153 & E151/E152/E153 nonautomatic • BN151/BN152/BN153 & BE151/BE152/BE153 level float switch packaged with Piggyback Variable Level Float Switch • Operates at temperatures to 130°F (54°C) in effluent • 1/3, .4 & 1/2 HP, 1Ph 115V or 230V applications • All models include a 1½" x 2" PVC adapter fitting Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with nonautomatic pumps. “DOSE-MATE” EFFLUENT Model BN152/BN153 High Head Effluent MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP FAX (502) 774-3624 Manufacturers of . . . © Copyright 2010 Zoeller Co. All rights reserved. METERS FEET TOTAL DYNAMIC HEAD/FLOW PER MINUTE EFFLUENT AND DEWATERING PUMP PERFORMANCE CURVE MODEL 151/152/153 50 14 TOTAL DYNAMIC HEAD 12 45 153 40 35 10 152 30 8 6 25 151 20 15 4 10 MODEL 151 152 153 Feet Meters 5 1.5 10 3.0 15 4.6 20 6.1 25 7.6 30 9.1 35 10.7 40 12.2 Shut-off Head: Gal. Liters 50 189 45 170 38 144 29 110 16 61 ------30 ft. (9.1m) Liters Gal. 261 69 231 61 201 53 167 44 129 34 23 87 ----38 ft. (11.6m) Gal. Liters 77 291 70 265 61 231 52 197 42 159 33 125 22 85 11 42 44 ft. (13.4m) 014508B 2 5 Model 151 0 10 GALLONS LITERS 0 20 30 40 50 60 70 80 90 100 Models 152 / 153 6 7/32 6 7/32 40 80 120 160 200 240 280 320 360 3 7/8 3 7/8 4 5/8 4 5/8 FLOW PER MINUTE 014508A CONSULT FACTORY FOR SPECIAL APPLICATIONS • Timed dosing panels available • Electrical alternators, for duplex systems, are available and supplied with an alarm • Variable level control switches are available for controlling single phase systems • Double piggyback variable level float switches are available for variable level long and short cycle controls • Sealed Qwik-Box available for outdoor installations - See FM1420 • Over 130°F (54°C) special quotation required 3 7/8 3 7/8 3 7/8 3 7/8 1 1/2" NPT 12 1/8 11 11/16 5 3/8 4 15/16 151/152/153 Series SK2444 Model N151 BN151 E151 BE151 N152 BN152 E152 BE152 N153 BN153 E153 BE153 151/152/153 MODELS Volts-Ph Mode Amps 115 1 Non 6.0 115 1 Auto 6.0 230 1 Non 3.2 230 1 Auto 3.2 115 1 Non 8.5 115 1 Auto 8.5 230 1 Non 4.3 230 1 Auto 4.3 115 1 Non 10.5 115 1 Auto 10.5 230 1 Non 5.3 230 1 Auto 5.3 Control Selection Simplex Duplex 1 2 or 3 Included 2 or 3 1 2 or 3 Included 2 or 3 1 2 or 3 Included 2 or 3 1 2 or 3 Included 2 or 3 1 2 or 3 Included 2 or 3 1 2 or 3 Included 2 or 3 SK2064 "Easy assembly" (pump & discharge pipe not included.) SELECTION GUIDE OPTIONAL PUMP STAND P/N 10-2421 1. Single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477. 2. See FM0712 for correct model of Electrical Alternator E-Pak. 3. Variable level control switch 10-0743 used as a control activator, specify duplex (3) or (4) float system. • • • • • All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). NOTE: Make sure float is free from obstruction. Reduces potential clogging by debris Replaces rocks or bricks under the pump Made of durable, noncorrosive ABS Raises pump 2" off bottom of basin Provides the ability to raise intake by adding sections of 1½" or 2" PVC piping • Attaches securely to pump • Accommodates sump, dewatering and effluent applications RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. © Copyright 2010 Zoeller Co. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : mikem Create Date : 2009:12:03 10:36:01-05:00 Modify Date : 2017:01:20 11:13:57-05:00 Subject : FM1919 XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Creator : mikem Title : fm1919- 151/152/153 Effluent Series DOSE MATE Description : FM1919 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:01:20 11:13:57-05:00 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:e456f72b-b1eb-42e2-b188-744dcce1adc3 Instance ID : uuid:0b70d4b4-b88c-49f1-96bc-4fad63428705 Page Count : 2EXIF Metadata provided by EXIF.tools