4WHV
3WHV

MODELS 3WHV, V3WHV, 3WHR,
4WHV, V4WHV and 4WHR
SUBMERSIBLE SOLIDS
HANDLING PUMPS
INSTALLATION AND SERVICE MANUAL
For use with product built with Regal-Beloit motor.

NOTE! To the installer: Please make sure you provide this manual to the owner of the equip­ment or to the responsible
party who maintains the system.
Part # 23833A661 | © 2013 Pentair Ltd. | 11/21/13

SAFETY WARNINGS:
Before Installation: This manual contains
important information for the safe use of this
product. Read this manual completely and follow
the instructions carefully. Reasonable care and
safe methods relating to the installation and
operation of this product should be practiced.
Check local codes and requirements before
installation.

m DO NOT run the pump dry. Dry running can
overheat the pump (causing burns to anyone
handling it) and will void the warranty.
m The pump normally runs hot. To avoid burns,
allow it to cool for 30 minutes after shutdown
before handling it.
m Submersible sump pumps are not approved
for use in swimming pools, recreational water
installations, decorative fountains or any
installation where human contact with the
pumped fluid is common. Pump designed to
be installed in a sump or wet location where
drainage collects.

m DANGER: Risk of Electrical Shock or
Electrocution. May result in serious injury
or death or fire hazard. Installer must
disconnect all electrical sources prior to
installation, handling or servicing. Only
qualified personnel may install this system.
NFPA 70/National Electric Code (NEC) or
local codes must be followed. System must
be properly grounded according to NEC. Do
not lift pump by power cord.

DO NOT THROW AWAY OR LOSE THIS
MANUAL. Keep it in a safe place so that you
may refer to it often for the continued safe
operation of the product.
PUMP MODELS:
These instructions cover the installation and
service of the 3WHV/V3WHV/3WHR and
4WHV/V4WHV/4WHR series of solids handling
pumps and guide rail systems for the horizontal
discharge models only. These models are
designed for handling raw sewage and
wastewater. Do not use for acid wastewater.
The pumps have vortex, solids handling
impellers. These pumps will pass 3" dia. solids
and has a 3" or 4" std. flange discharge.

m DANGER: Biohazard Risk. Once wastewater
source has been connected to system,
Biohazard Risk exists. Installer(s) and/or
service personnel must use proper Personal
Protective Equipment and follow handling
procedures per OSHA 29 CFR 1910.1030
when handling equipment after wastewater
source has been connected to system.
m DANGER: Risk of Asphyxiation. Installer(s)
and/or service personnel must use proper
Personal Protective Equipment and follow
OSHA 29 CFR 1910.146 or OSHA 29 CFR
1926. Pump may be installed in a location
classified by as a confined space.

SEAL FAILURE (4WHV/ V4WHV/ 4WHR ONLY):
These pumps have a probe installed in the seal
chamber, so that any leakage past the lower seal
is detected. A red warning light at the control
panel comes on if water enters the seal chamber.
This is an indicator only and does not stop the
motor. It warns that the seal should be replaced
immediately. LONGER RUNNING WITHOUT
SEAL REPLACEMENT COULD DAMAGE
MOTOR. MOTOR MUST GO TO AUTHORIZED
SERVICE STATION FOR SEAL REPLACEMENT.

m DANGER: Risk of Fire or Explosion. Do
not smoke or use open flames in or around
this system. This system is intended for
use in hazardous locations per NFPA 70
National Electric Code. Do not pump
flammable liquids.
m DANGER: Cutting Risk. Risk of serious
cutting or amputation exists. Disconnect
all power sources prior to servicing pump.
Pump may start without warning.

HEAT SENSOR (4WHV/ V4WHV/ 4WHR ONLY):
All single and three phase pumps have motor
heat sensors that are externally wired to the
control panel. Any motor temperature above the
sensor rating will open the heat sensor and stop
the motor. The sensor will automatically close
upon cooling. It is important that the heat sensor
wires and seal failure wires are connected at the
panel terminal block. Warranty is void if wires are
not connected or are jumped.

m DO NOT modify the cord and plug. When
using the cord and plug, plug into a grounded
outlet only. When wiring to a system control,
connect the pump ground lead to the
system ground.

CAUTION: The single phase pumps with
automatic heat sensor reset will restart without
warning as the motor cools. Therefore, never do
service work on the pump unless power supply is
disconnected.
23833A661 11/21/13

2

ELECTRICAL CONTROLS
(All Models)

WARNING: On three phase pumps only qualified
persons shall conduct services and installation
of this pump. The pump must be wired by a
qualified electrician, using an approved starter
box and switching device.

FLOAT SWITCH INSTALLATION
1. Level Controls are held by support bracket and
cords are adjusted for proper depth.
a. Lower Turn-Off Control should be set so that
pump stops when water level is about at the top
of the volute.
b. First Turn-On Control is set to start pump when
level is at height specified above pump.
c. Second Turn-On Control of a duplex pump
system is set at height specified above first turnon control.
d. Alarm Control is set about 6" to 12" above the
highest Turn-On Control.
e. No control should be set above basin inlet invert.

CAUTION: Never pull pump or work on control
box until incoming power is disconnected.
Never run motor until green ground conductor is
connected to a good outside ground. Never pull
electrical cable to lift pump.
If the control panel is not located near the pump,
consult wire gauge table for permissible wire
gauge to run between the control panel and the
junction box at the wet well.
CALIFORNIA PROPOSITION 65 WARNING:
This product and related
accessories contain chemicals known to the
State of California to cause cancer, birth
defects or other reproductive harm.

MAKING ELECTRICAL CONNECTIONS
1. If control panel is mounted directly on basin top, 		
the power and control wires are taken directly to 		
control box and are sealed in the cord pallet with 		
cord grip connectors.
2. If panel is installed remote from basin, the cords 		
can be taken through a conduit to control panel, 		
or junction box can be used in the basin to make 		
connections. The Myers junction box has a built-in
sealing connector to seal the outgoing wires. If
other than Myers junction box is used, a separate
sealing connector must be used where wires leave 		
the basin.

OIL FILLED MOTOR:
The motor chamber and seal chamber are
dielectric oil-filled for good heat transfer and
lubrication of bearings and seals. The motor
requires no other lubrication. Oil level in the
motor housing should be to the bottom of the oil
fill plug with the pump in a vertical position. Do
not overfill the motor housing since some space
is required for oil expansion. Oil level in the seal
chamber should be checked with the pump lying
horizontally with the fill plug at the top. The oil
level should be approximately 3/4" from the
outside surface of the housing. Transformer oil
should be used and may be purchased from your
Myers® dealer.

CAUTION: If cords are taken directly through a 		
conduit to control box, a seal fitting must be used at
inlet of conduit to prevent gas vapors from getting
to control box. This type of installation is generally
not recommended because the sealing cement
must be broken to remove a cord.

AIR VENTING:
Upon initial filling of the wet well with the water,
air may be trapped in the pump volute. To vent
off this air, a 5/32" diameter hole is located in the
volute. BE SURE THIS VENT HOLE IS CLEAN
AFTER ANY SERVICE WORK ON PUMP.

MOTOR ELECTRICAL CONNECTIONS
Single phase motors are for 230 volts only. A special
control panel with start and run capacitors and start
relay are required for these pumps.
These control panels must be obtained from Myers
(or must be approved by Myers) or warranty on motor
is void. Also, warranty is void if the heat sensor and
seal fixture wires are not connected properly to control
box terminal strip.
CAUTION: Pump motor is not to be taken apart in
the field. Motors under warranty must be serviced by
Myers authorized repair station or be sent to factory.

3

23833A661 11/21/13

3WHV / V3WHV / 3WHR
IMPELLER AND VOLUTE PART NUMBERS
Pump
3WHV/V3WHV10M4-21
3WHV/V3WHV10M4-03
3WHV/V3WHV10M4-23
3WHV/V3WHV10M4-43
3WHV/V3WHV10M4-53
3WHV/V3WHV15M4-21
3WHV/V3WHV15M4-03
3WHV/V3WHV15M4-23
3WHV/V3WHV15M4-43
3WHV/V3WHV15M4-53
3WHV/V3WHV20M4-21
3WHV/V3WHV20M4-03
3WHV/V3WHV20M4-23
3WHV/V3WHV20M4-43
3WHV/V3WHV20M4-53
3WHV/V3WHV20M4-43
3WHV/V3WHV30M4-21
3WHV/V3WHV30M4-03
3WHV/V3WHV30M4-23
3WHV/V3WHV30M4-43
3WHV/V3WHV30M4-53
3WHV/V3WHV50M4-21
3WHV/V3WHV50M4-03
3WHV/V3WHV50M4-23
3WHV/V3WHV50M4-43
3WHV/V3WHV50M4-53
3WHR15M4-01
3WHR15M4-21
3WHR15M4-03
3WHR15M4-23
3WHR15M4-43
3WHR15M4-53
3WHR20M4-01
3WHR20M4-21
3WHR20M4-03
3WHR20M4-23
3WHR20M4-43
3WHR20M4-53
3WHR30M4-21
3WHR30M4-03
3WHR30M4-23
3WHR30M4-43
3WHR30M4-53
3WHR50M4-21
3WHR50M4-03
3WHR50M4-23
3WHR50M4-43
3WHR50M4-53

RPM
1750

1750

1750

1750

1750

1750

1750

hp
1

1.5

2

3

5

1.5

2

Trim

Impeller

5

Pump Catalog No.
3WHV10M4-21
V3WHV10M4-21
3WHV10M4-03
V3WHV10M4-03
3WHV10M4-23
V3WHV10M4-23
3WHV10M4-43
V3WHV10M4-43
3WHV10M4-53
V3WHV10M4-53
3WHV15M4-21
V3WHV15M4-21
3WHV15M4-03
V3WHV15M4-03
3WHV15M4-23
V3WHV15M4-23
3WHV15M4-43
V3WHV15M4-43
3WHV15M4-53
V3WHV15M4-53
3WHV20M4-21
V3WHV20M4-21
3WHV20M4-01
V3WHV20M4-01
3WHV20M4-03
V3WHV20M4-03
3WHV20M4-23
V3WHV20M4-23
3WHV20M4-43
V3WHV20M4-43
3WHV20M4-53
V3WHV20M4-53
3WHV30M4-21
V3WHV30M4-21
3WHV30M4-03
V3WHV30M4-03
3WHV30M4-23
V3WHV30M4-23
3WHV30M4-43
V3WHV30M4-43
3WHV30M4-53
V3WHV30M4-53
3WHV50M4-21
V3WHV50M4-21
3WHV50M4-03
V3WHV50M4-03
3WHV50M4-23
V3WHV50M4-23
3WHV50M4-43
V3WHV50M4-43
3WHV50M4-53
V3WHV50M4-53

24415E030

5.5

22946C511

6

22946C507

6.5

3WHV – 22945D000
V3WHV – 22945E100

22946C503

6.75

5

Volute

22946C501

0708120002

5.25

070812022
27706D000

1750

1750

3

5

6

6.75

070812012

070812032

Shaft w/Rotor

Stator Only

Housing w/Stator

24416C000

24407C211

24406D120K

24416C001

24407C212

24406D125K

24416C001

24407C213

24406D130K

24416C001

24407C213

24406D135K

24416C001

24407C214

24406D140K

24416C000

24407C211

24406D120K

24416C001

24407C212

24406D125K

24416C001

24407C213

24406D130K

24416C001

24407C213

24406D135K

24416C001

24407C214

24406D140K

24416C002

24407C215

24406D145K

24416C002

24407C239

24406D195K

24416C003

24407C216

24406D150K

24416C003

24407C217

24406D155K

24416C003

24407C217

24406D160K

24416C003

24407C218

24406D165K

24416C004

24407C219

24406D170K

24416C004

24407C220

24406D175K

24416C004

24407C221

24406D180K

24416C004

24407C221

24406D185K

24416C004

24407C222

24406D190K

24416C004

24407C204

24406D170K

24416C004

24407C220

24406D175K

24416C004

24407C221

24406D180K

24416C004

24407C221

24406D185K

24416C004

24407C222

24406D190K

REGAL MOTOR END PARTS LIST
Ref.
1
2
3
4
5
6
7
8
9
10
11

Description
35' CORD ASSEMBLY 14-4
35' CORD ASSEMBLY 10-4
35' CORD ASSEMBLY 8-4 SOOW
35' CORD ASSEMBLY 8-4 W
SCREW; MACH ST 10-24UNC x 3/8 LG
WASHER; LOCK SHKPRF INTERNAL ST NO 10
PLATE; SEALING, UPPER WGL SERIES
SCREW; CAP HEX ST SPEC #10-24UNC x 7/8 LG
GROMMET; SEALING POWER WHV SERIES
PLATE; SEALING LOWER WGL SERIES ST
WIRE; ELECT 10 GA 1 STR RED 12 LG
WIRE; ELECT 10 GA 1 STR WHITE 12 LG
WIRE; ELECT 10 GA 1 STR BLACK 12 LG
WASHER; SPRING FINGER 1.189 ID x 1.830 OD

23833A661 11/21/13

Qty.

Part Number

Ref.

1
1
1
1
3
1
1
1
1
1
1
1
1
2

22569B104
22569B031
22569B032
22569B102
05434A043
06107A015
24321A000
24322A000
24323A001
24324A000
22500A121
22500A122
22500A123
19331A006

12
13
14
15
16
17
18
19
20
21
22
23
24
25

4

Description
BEARING, BALL, UPPER
HOUSING; MOTOR 3WHV SEWAGE PUMP CI
STATOR
SHAFT W/ ROTOR
BEARING, BALL, LOWER
GASKET; RUBBER TETRASEAL 7 x 6-3/4 x 1/8
SEAL, SHAFT 1-1/4
HOUSING; SEAL CI 3HP 3WHV SEWAGE PUMP
SCREW; CAP SKT HD SST 7/16-14UNC-3A x 1-1/2 LG
PLUG; PIPE MALL GALV 1/2 SQ HD
BOLT, EYE; ELECTRO GALV 3/8-16THD x 1
GASKET; RUBBER TETRASEAL 3-3/4 x 3-1/2 x 1/8
SCREW; CAP HEX SST 7/16-14UNC x 2 LG
GASKET; VELLUMOID 10-3/8 x 8-7/16 x 1/32

Qty.

Part Number

1
1
1
1
1
1
1
1
4
1
1
1
4
1

08565A022
24406D001
SEE CHART
SEE CHART
066650181
05014A181
049160001
24414D000
06106A035
05022A039
21929A002
05014A133
19102A022
05231A079

3WHV / V3WHV / 3WHR

WET END DRAWINGS

3WHV
E

21

1

22
23
5

2

4

3

B
A
C

6
7
8
9
10

D

V3WHV VOLUTE
11
12

15
24
14
13

3WHR

17

E

19
16
18
20

25

B

A
C
D

3WHV / V3WHV / 3WHR
Ref.
A
B
C
D
E

5

Description
VOLUTE
IMPELLER
WASHER; RETAINER, W/PIN, FOR 4R & 3WHV SERIES
SCREW; CAP HEX SST 3/8-16 x 1 LG
KEY; SQ SST 1/4 x 1/4 x 11/16

Qty.
1
1
1
1
1

Part Number
See Table
See Table
23609A001
19101A017
05818A074

23833A661 11/21/13

4WHV / V4WHV / 4WHR
IMPELLER AND VOLUTE PART NUMBERS
Pump
4WHV/V4WHV30M4-21
4WHV/V4WHV30M4-03
4WHV/V4WHV30M4-23
4WHV/V4WHV30M4-43
4WHV/V4WHV30M4-53
4WHV/V4WHV50M4-21
4WHV/V4WHV50M4-03
4WHV/V4WHV50M4-23
4WHV/V4WHV50M4-43
4WHV/V4WHV50M4-53
4WHV/V4WHV75M4-03
4WHV/V4WHV75M4-23
4WHV/V4WHV75M4-43
4WHV/V4WHV75M4-53
4WHV/V4WHV100M4-03
4WHV/V4WHV100M4-23
4WHV/V4WHV100M4-43
4WHV/V4WHV100M4-53
4WHR30M4-21
4WHR30M4-03
4WHR30M4-23
4WHR30M4-43
4WHR30M4-53
4WHR50M4-21
4WHR50M4-03
4WHR50M4-23
4WHR50M4-43
4WHR50M4-53
4WHR75M4-03
4WHR75M4-23
4WHR75M4-43
4WHR75M4-53

RPM
1750

1750

1750

1750

1750

1750

1750

hp
3

5

7.5

10

3

5

7.5

Trim
6

7

7.5

8

6

6.5

5.25

Impeller

Volute

Pump Catalog No.
4WHV/4WHR30M4-21
V4WHV30M4-21
4WHV/4WHR30M4-03
V4WHV30M4-03
4WHV/4WHR30M4-23
V4WHV30M4-23
4WHV/4WHR30M4-43
V4WHV30M4-43
4WHV/4WHR30M4-53
V4WHV30M4-53
4WHV/4WHR50M4-21
V4WHV50M4-21
4WHV/4WHR50M4-03
V4WHV50M4-03
4WHV/4WHR50M4-23
V4WHV50M4-23
4WHV/4WHR50M4-43
V4WHV50M4-43
4WHV/4WHR50M4-53
V4WHV50M4-53
4WHV/4WHR75M4-03
V4WHV75M4-03
4WHV/4WHR75M4-23
V4WHV75M4-23
4WHV/4WHR75M4-43
V4WHV75M4-43
4WHV/4WHR75M4-53
V4WHV75M4-53
4WHV/4WHR100M4-03
V4WHV100M4-03
4WHV/4WHR100M4-23
V4WHV100M4-23
4WHV/4WHR100M4-43
V4WHV100M4-43
4WHV/4WHR100M4-53
V4WHV100M4-53

22711C518

22711C510

4WHV – 22712D000
V4WHV – 22712E100

22711C506

22711C502

070811122

22854D100

070811112

070811102

Shaft w/Rotor

Stator Only

Housing w/Stator

24408C000

24407C200

24406D020K

24408C000

24407C201

24406D025K

24408C000

24407C202

24406D031K

24408C000

24407C202

24406D035K

24408C000

24407C203

24406D040K

24408C000

24407C204

24406D045K

24408C000

24407C205

24406D050K

24408C000

24407C206

24406D055K

24408C000

24407C206

24406D060K

24408C000

24407C207

24406D065K

24408C000

24407C208

24406D070K

24408C000

24407C209

24406D075K

24408C000

24407C209

24406D080K

24408C000

24407C210

24406D085K

24408C000

24407C208

24406D070K

24408C000

24407C209

24406D075K

24408C000

24407C209

24406D080K

24408C000

24407C210

24406D085K

REGAL MOTOR END PARTS LIST
Ref.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Description
35' CORD ASSEMBLY 14-4
35' CORD ASSEMBLY 10-4
35' CORD ASSEMBLY 8-4 SOOW
35' CORD ASSEMBLY 8-4 W
SCREW; MACH ST 10-24UNC x 3/8 LG
WASHER; LOCK SHKPRF INTERNAL ST NO 10
PLATE; SEALING, UPPER WGL SERIES
SCREW; CAP HEX ST SPEC #10-24UNC x 7/8 LG
GASKET; RUBBER TETRASEAL 3-3/4 x 3-1/2 x 1/8
GROMMET; SEALING POWER WHV SERIES
PLATE; SEALING LOWER WGL SERIES ST
WIRE; ELECT 10 GA 1 STR RED 12 LG
WIRE; ELECT 10 GA 1 STR WHITE 12 LG
WIRE; ELECT 10 GA 1 STR BLACK 12 LG
WASHER; SPRING FINGER 1.189 ID x 1.830 OD
BEARING, BALL, UPPER
HOUSING; MOTOR 4WHV SEWAGE PUMP CI
STATOR
SHAFT W/ ROTOR

23833A661 11/21/13

Qty.

Part Number

Ref.

1
1
1
1
6
2
2
2
1
1
2
1
1
1
2
1
1
1
1

22569B104
22569B031
22569B032
22569B102
05434A043
06107A015
24321A000
24322A000
05014A133
24323A001
24324A000
22500A121
22500A122
22500A123
19331A006
08565A022
24406D001
SEE CHART
SEE CHART

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

6

Description
BEARING, BALL, LOWER
GASKET; RUBBER TETRASEAL 7 x 6-3/4 x 1/8
HOUSING; BEARING 4WHV SEWAGE PUMP CI
SEAL, SHAFT 1-1/2
RING; RET EXTERNAL SST 1-1/2 SHAFT
HOUSING; LOWER SEAL 4WHV SEWAGE PUMP CI
SCREW; CAP HEX SST 7/16 x 1-1/2 LG
GASKET; VELLUMOID 10-3/8 x 8-7/16 x 1/32
WIRE; ELECT 16 GA 1 STR BLACK 12 LG
WIRE; ELECT 16 GA 1 STR WHITE 12 LG
GROMMET; SEALING CONTROL 4WHV SERIES
BOLT, EYE; ELECTRO GALV 3/8-16THD x 1
SCREW; CAP HEX SST 7/16-14UNC x 2LG
WIRE; ELECT 16 GA 1 STR YELLOW 20 LG
FERRULE; RUBBER .312 OD .171 ID .265 LG ONE HOLE
PLUG; SPECIAL 1/2 HEX BR ROD
ELECTRODE; WIRE 4-1/2 LG
SCREW; CAP SKT HD SST 3/8-16UNC-3A x 1 LG
GASKET; RUBBER 7-1/2 x 7-1/4 x 1/8 THK

Qty.

Part Number

1
1
1
2
1
1
4
1
1
1
1
1
4
1
1
1
1
4
1

08565A027
05014A181
24411D000
00920-001-1
12558A018
24412D000
19102A006
05231A079
22500A124
22500A125
24323A002
21929A002
19102A022
22500A126
12619A001
21577A000
21792A003
06106A028
05014A176

4WHV / V4WHV / 4WHR

WET END DRAWINGS

4WHV

1

E
25
26
28
2

6

4

3
G

RE

EN

GREEN

5

27

C

D

B

7
8

A

9
10
11

V4WHV VOLUTE

12
13
14
15
16
29

18

30

19
17
20

21
23

31

4WHR

32
33
34
35
22

24

E
A
B
C

D

4WHV / V4WHV / 4WHR
Ref.
A
B
C
D
E

7

Description
VOLUTE
IMPELLER
WASHER; RETAINER, W/PIN, FOR 4V & 4WHV SERIES
SCREW; CAP HEX SST 300 1/2-13UNC x 1-1/4 LG
KEY; SQ SST 1/4 x 1/4 x 13/16

Qty.
1
1
1
1
1

Part Number
See Table
See Table
23609A002
19103A052
05818A066

23833A661 11/21/13

N
GREE

WH
T.
BLK.
RED
T3

8A

GROUND
SCREW
GROMMET

BLACK
RED

N
GREE

GROUND
SCREW
GROMMET

WHT.

BLACK
RED

8

T1
T2

WHT.

8A

BLACK
RED

8

BLUE

RED

WH
T.
BLK.

3WHV / V3WHV / 3WHR WIRING DIAGRAMS

230 V – SINGLE PHASE

200 OR 575 V – THREE PHASE

N
GREE

WH

N
GREE

RED

8

T.
BLK.
RED

MOTOR STATOR

WH
T.
BLK.

MOTOR STATOR

BL

8

T4

T7
T8

T6

T5

T9
T3

T2

T4

T1

T5

T1

T2

T6

T7

T8

T9
T3

WH

8A

8B

MOTOR STATOR

MOTOR STATOR

460 V – THREE PHASE

230 V – THREE PHASE

23833A661 11/21/13

GROUND
SCREW
GROMMET

ITE
.
AC
RE K
D

GROUND
SCREW
GROMMET

BLACK
RED

WHT.

8

8

4WHV / V4WHV / 4WHR WIRING DIAGRAMS

16/4

GREEN

16/4

.
BLK T.
H
W D
RE

GREEN

Motor Stator

54

T4

460 V – THREE PHASE

OW
YELL

TE
WHI
P2

BLACK

40

P1

T7

T5
T8

T6

T1

Heat
Sensor
230 V – THREE PHASE on Stator

T3

T1

T9

40

Motor Stator

54

7

T2

W
YELLO

P2

7B

Ground
Screw
Grommets

WH
T
BLA .
CK
RE
D

WHITE

54

N
GREE

WH
T
BLK. .
RED

.
BLK
T.
WH D
RE
BLAC
K

40
7

T6
T5
T4

P1

T7

T2

Control
Cord

10/4

GREEN

N
GREE

WH
T
BLK. .
RED
T8

T9

T3

Power
Cord

7B

54

Seal Leak
Electrode

16/4

Ground
Screw
Grommets

WHT.
BLACK
RED

7

W
YELLO

Heat
Sensor
on Stator

54

Control
Cord

10/4

40

200 OR 575 V – THREE PHASE

Seal Leak
Electrode
Power
Cord

40

WHITE
P2

P1

Motor Stator

40

Heat
Sensor
on Stator

.
BLK
T.
WH D
RE

WH
T
BLK. .
RED

54

T1
T2
T3

W
YELLO

BROWN

7A

Ground
Screw
Grommets

BLAC
K

WHITE

BLACK

230 V – SINGLE PHASE

PURPLE

Motor Stator

7

WHT.
BLACK
RED

.
BLK
T.
WH D
RE

40

GREEN

54

BLUE
BLACK
RED

7A

N
GREE

WH
T
BLK. .
RED
WHT.
BLACK
RED

Ground
Screw
Grommets

Control
Cord

10/4

16/4

10/4

7

Power
Cord

Control
Cord

N
GREE

Power
Cord

Heat
Sensor
on Stator

40

54

Seal Leak
Electrode

Seal Leak
Electrode

9

23833A661 11/21/13

REMOVING PUMP CASE AND IMPELLER
In case of wear, damage due to dropping, plugged
pump, or replacing a defective motor, the pump volute
case and impeller can be removed in the field.
1. Remove bolts between seal housing flange and
volute case. The motor and impeller can now be
lifted off as a unit.
2. If necessary to remove impeller, lay pump on its
side. With a screwdriver bend the tabs of the
lockwasher away from the hex head bolt.
3. Loosen and remove the bolt by turning counterclockwise. Since Loctite® is used to secure the
bolt and is applied to the shaft/impeller interface,
heating of the shaft end to 450º F will usually
be required.
4. Impeller is mounted by a straight fit with driving
key. Pry evenly on opposite impeller sides with
two large screwdrivers or small bars behind
the impeller.
5. Set motor on end with shaft up after removing
impeller so that oil will not drain past the seal.

REPLACING IMPELLER AND PUMP CASE
1. Apply Loctite #680; before assembly, in keyway,
in the impeller bore (lower shaft O.D.), and on the
threads of the hex head cap screw.
2. Before placing the impeller on the shaft, be sure
the mechanical seal and its spring are in place.
3. Position retaining washer with long pin extension
in keyway.
4. Assemble hex head cap screw and tighten
securely.
CAP SCREW

TORQUE VALUE

3/8-16
1/2-13
5/8-11

20 ft.-lbs.
43 ft.-lbs.
93 ft-lbs.

3/4-10

128 ft.-lbs.

TROUBLE CHECK LIST
Troubles listed generally pertain to the pump and auxiliary components. Other trouble can occur from
a faulty control box. These will be listed with the control box instructions.

CONDITION

PROBABLE CAUSE

Pump runs but does not pump
liquid from basin.

1.
		
		
2.
		
3.
		
4.
		
5.
6.
		
7.
8.
		
		

Pump impeller may be air locked; this occasionally occurs on 		
a new installation. Start and stop pump several times to purge
air. Be sure air vent hold in volute case is clean.
Run additional water into basin so that pump will be
submerged deeper to clear air.
If pump is three phase, rotation may be wrong. See
instructions for checking proper rotation.
If pump has been installed for some time and does not pump,
it may be clogged at inlet.
Discharge gate valve may be closed.
Discharge check valve may be clogged or have a broken
clapper or spring.
Discharge head may be too high. Check elevation.
If above checks do not locate trouble, motor rotor may be
loose on shaft which allows motor to run but will not turn
impeller or only at low RPM.

Red light comes on at
control box.

1.
		
		
		
		

This indicates some water has leaked past the lower seal
and has entered the seal chamber and made contact with 		
the electrode probe. Pump must be removed immediately
from basin for replacement of lower seal. This preventive repair
will save an expensive motor.

23833A661 11/21/13

10

TROUBLE CHECK LIST (Cont’d)
CONDITION

PROBABLE CAUSE

1.
Overload trips at control box
and alarm buzzer or flashing red 		
light comes on due to high water 		
level in basin.
2.
		
3.
		

Push red reset button to reset overload. If overload
trips again after short run, pump has some damage and must
be removed from basin for checking.
Trouble may be from clogged impeller causing motor to
overload or could be from failed motor.
Trouble may be from faulty component in control box. Always
check control box before removing pump.

Yellow run light stays on
continuously.

1.
2.
		
3.
		
4.
		
5.
		

Indicates H-O-A switch may be in the Hand position.
Level control switch may have failed causing pump to
continue to operate when water is below lower control.
Impeller may be partially clogged causing pump to
operate at much reduced capacity.
Gate valve or check valve may be clogged causing low
pump flow.
Pump may be air logged. Lift arm on check valve to vent off
air. Also, check that the 5/32" vent hole in volute is open.

Circuit breaker trips.

1.
		
		
		
		
2.
		
3.
		
		

Reset breaker by pushing clear down on handle then back
to On position. If breaker trips again in few seconds, it			
indicates excessive load probably caused by a short in the 		
motor or control box. Check out instructions given with 		
control box before pulling pump.
If this condition happens after an electrical storm, motor or
control box may be damaged by lightning.
Resistance reading of the motor with lead wires disconnected
from the control box can determine if trouble is in motor or
control box.

Pump is noisy and pump rate
is low.

1.
		
2.
		
3.

Impeller may be partially clogged with some foreign objects
causing noise and overload on the motor.
Impeller may be rubbing on wear ring due to bent shaft or
misalignment.
Pump may be operating too close to shut-off. Check head.

Grease and solids have
accumulated around pump
and will not pump out
of basin.

1.
2.
		
		
		
		
3.
		

Lower control which may be set too high.
Run pump on manual operation for several minutes with small
amount of water running into basin to clean out solids and
grease. This allows pump to break suction and surge,
breaking up the solids. If level switch is set properly, this
condition generally will not occur.
Trash and grease may have accumulated around floats
causing pump to operate erratically.

11

23833A661 11/21/13

STANDARD LIMITED WARRANTY
Myers® warrants its products against defects in material and workmanship for a period of 12 months from the date
of shipment from Myers or 18 months from the manufacturing date, whichever occurs first - provided that such
products are used in compliance with the requirements of the Myers catalog and technical manuals for use in
pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids.
During the warranty period and subject to the conditions set forth, Myers, at its discretion, will repair or replace to
the original user, the parts which prove defective in materials and workmanship. Myers reserves the right to change
or improve its products or any portions thereof without being obligated to provide such a change or improvement
for prior sold and/or shipped units.
Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start
up through the Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m.
Warranty is effective only if Myers authorized control panels are used. All seal fail and heat sensing devices must
be hooked up, functional and monitored or this warranty will be void. Myers will only cover the lower seal and labor
thereof for all dual seal pumps. Under no circumstance will Myers be responsible for the cost of field labor, travel
expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an
authorized Myers service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or
maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident
or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units which
are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is
moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and
manufactured; (g) to any unit which has been repaired or altered by anyone other than Myers or an authorized
Myers service provider; (h) to any unit which has been repaired using non factory specified/OEM parts.
Warranty Exclusions: MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND
THE DESCRIPTION ON THE FACE HEREOF. MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.
Liability Limitation: IN NO EVENT SHALL MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL,
INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY MYERS
PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM
IMPROPER INSTALLATION. MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS
WARRANTY, FOR IMPROPER INSTALLATION. MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.
Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental
or consequential damages and therefore such limitations may not apply to you. No warranties or representations at
any time made by any representatives of Myers shall vary or expand the provision hereof.

740 East 9th Street
Ashland, Ohio 44805-1969
419-289-1144
www.femyers.com

Warranty Rev 12/11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:4eef6d7b-b7f1-3f47-9f22-3a6d9c9cf081
Original Document ID            : adobe:docid:indd:46a2161a-d919-11db-87b8-c1c5c7a74048
Document ID                     : xmp.id:DF1EE4DF8C3168118083C1AB0B8D662A
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:DE1EE4DF8C3168118083C1AB0B8D662A
Derived From Document ID        : adobe:docid:indd:46a2161a-d919-11db-87b8-c1c5c7a74048
Derived From Original Document ID: adobe:docid:indd:46a2161a-d919-11db-87b8-c1c5c7a74048
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2013:11:21 16:06:43-05:00
Create Date                     : 2013:11:21 16:06:43-05:00
Modify Date                     : 2013:11:25 11:55:40-05:00
Metadata Date                   : 2013:11:25 11:55:40-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Layout                     : TwoPageRight
Page Mode                       : UseThumbs
Page Count                      : 12
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu