536703 1 Zoeller 10 1044 Brochure FM0486 Electrical Alternator Control Panel Catalog Sheet User Manual
User Manual: Pump 536703 1 Zoeller 10-1044 Brochure
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
SECTION: 4.10.010 FM0486 0306 Supersedes 0704 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 visit our web site: www.zoeller.com ELECTRICAL ALTERNATOR CONTROL PANEL - FOR DUPLEX INSTALLATIONS An Electrical Alternator is used on a Duplex pump application where automatic alternation of the pumps is desired for added protection in residential or commercial applications. With one pump operating to handle normal flow, a second pump becomes operational in the event the water level continues to rise. The built-in alarm system, a standard feature, can be connected to sound when the second pump becomes operational (3-float switch system) or independently (4-float switch system). All electrical systems must be installed by a qualified electrician and according to the National Electrical Code. (See Section 430-71 though 430-113, plus any others that apply.) NEMA 1 ENCLOSURE Control Panel Features: • • • • • • • • • • • • • • • • • • • • Hand-Off-Auto Toggle Switch for each pump. Green pump run pilot light for each pump. Alarm test and silence switches. Red pilot light (Nema 1 Only) and audible alarm with 83 to 85 decibel rating for a high water condition. Red Alarm Beacon included with Nema 4X enclosure. Auxiliary Dry Contact. High Water Alarm. On Single Phase - Circuit breaker for each pump. On Three Phase - Motor protective switch with overload protection. Magnetic starter for each pump. Alternating mechanism. Numbered terminal strip for connecting pumps and variable level float switches. Nema 1 - general purpose or Nema 4X - Watertight enclosures available. Integral auxiliary terminal board connections (dry contact) for remote alarm devices. 3 or 4 variable level float switch control operation. 10-0092 Three 20’ float switches included with single phase panels. UL Listed. 2 Year Warranty The use of off-the-shelf components provide for relatively easy field maintenance and repair. Float switches not included with three phase panels (See FM0526). NEMA 4X ENCLOSURE CONTROL PANEL USED WITH SINGLE PHASE PUMPS NEMA 1 ENCLOSURE WITH 20’ FLOAT SWITCH Order No. Dimensions HxWxD Volts Amp Range 10-1039 10-1040 10-0092* 12” x 10” x 6” 12” x 10” x 6” 12” x 10” x 6” 115 115 115/200/230 7-15 15-20 0-20 NEMA 4X ENCLOSURE WITH 20’ FLOAT SWITCH Order No. 10-1041 10-1042 10-1043 10-1044 10-1045 10-1046 10-0093* Dimensions HxWxD 12” x 10” x 6” 12” x 10” x 6” 12” x 10” x 6” 12” x 10” x 6” 12” x 10” x 6” 12” x 10” x 6” 12” x 10” x 6” Volts 115 115 115/200/230 115/200/230 115/200/230 115/200/230 115/200/230 Amp Range 7-15 15-20 0-7 7-15 15-20 20-30 0-20 * Branch circuit protection provided by installing electrician. 10-0093 Products may not be exactly as illustrated NOTE: 600 and X600 Series single phase pumps require special panels that include start components. See Selection Guide FM0712 for correct panel selection. NOTE: All variable level float switches in this section are mechanically activated and do not contain mercury. © Copyright 2006 Zoeller Co. All rights reserved. CONTROL PANEL USED WITH THREE PHASE PUMPS DUPLEX ELECTRICAL ALTERNATING SYSTEM NEMA 4X ENCLOSURE (Float Switches not included) Order No. 10-1102 10-1104 10-1106 10-1108 10-1110 10-1111 10-1112 10-1114 10-1115 10-1183 10-1154 10-1156 10-1158 Dimensions HxWxD 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 9” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” 14” x 12” x 6” Volts* 200/230/460 200/230/460 200/230/460 200/230/460 200/230/460 200/230/460 200/230/460 200/230/460 200/230/460 200/208 575 575 575 Amp Range 1.0 - 1.6 1.6 - 2.5 2.5 - 4.0 4.0 - 6.3 6.0 - 10.0 9.0 - 14.0 13.0 - 18.0 17.0 - 23.0 20.0 - 25.0 23.0 - 32.0 1.6 - 2.5 2.5 - 4.0 4.0 - 6.3 *Three phase panel has multi-tap transformer with secondary fusing. ALARM LIGHT DISCONNECT PUMP POWER SUPPLY CONTROL & ALARM POWER SUPPLY (SINGLE PHASE ONLY) NOTE: ALARM - CONTROL CIRCUIT SHOULD BE SEPARATE FROM PUMP POWER (SINGLE PHASE ONLY) ELECTRICAL ALTERNATOR CONTROL PANEL NOTE: THREE PHASE PANELS HAVE A TRANSFOMER WITH SECONDARY FUSING. INDICATOR LAMPS (INSIDE ENCLOSURE) TOGGLE SWITCHES (INSIDE ENCLOSURE) ZOELLER UNICHCEK CHECK VALVE (2" OR 3") 4 FLOAT SYSTEM ALARM BELL "ON" BOTH PUMPS ALREADY ACTIVATED SET ABOVE OVERRIDE AND BELOW INLET 2" OR 3" DISCHARGE PIPE FLOOR FLANGE 4" HUB INLET ZOELLER FIBERGLASS OR POLYETHYLENE BASIN "ALARM-OVERRIDE LEVEL SET ABOVE "ON" FLOAT AND BELOW INLET BOTH PUMPS "ON" ALARM BELL "ON" 3 FLOAT SYSTEM ZOELLER FLOAT SWITCH ZOELLER SEWAGE PUMP 5" "ON" LEVEL PUMPS ALTERNATE OPERATION EACH CYCLE MAXIMIZE BASED ON DEPTH AND VOLUME OF BASIN MINIMUM "OFF" LEVEL Sequence of Operation for Duplex Panel 1. Operation can begin after the following: - Correct voltage is supplied to Panel - Panel is properly grounded - Pumps are connected correctly to Panel - Panel Circuit Breakers are closed - Floats are installed properly - Overload Protection is adjusted to Pump nameplate amps - Pump HOA Switches are set to “Auto” - Control On/Off Switch is set to “On” 2. When the “Stop” and “Lead” floats are closed Pump 1 will energize and the Pump 1 Pump Run Light will illuminate. Pump 1 will remain operational until the “Stop” float opens. 3. The next time the “Stop” and “Lead” floats are closed the Alternating Circuit will energize Pump 2 and the Pump 2 Pump Run Light will illuminate. Pump 2 will remain operational until the “Stop” float opens. This cycle will repeat each time the fluid level rises and falls. 4. If the fluid level continues to rise after the first pump has been energized the “Lag” float will close. When the “Lag” float has closed the second Pump will Energize. Both Pumps will remain operational until the “Stop” float opens. SK289 5. In a three float system when the “Lag” float is closed the following will also occur: - The External High Water Light will illuminate - The Audible High Water Horn will sound - The Auxiliary Dry Contacts will close 6. In a four float system, the alarm float should be the third float causing an alarm to sound when the lead pump fails to operate or the rate of in flow into the basin exceeds the capacity of one pump. When the alarm float is closed the following will occur. - The External High Water Light will illuminate - The Audible High Water Alarm will sound - The Auxiliary Dry Contacts will close As the liquid level continues to rise the fourth float will close, energizing the lag pump. The lag pump and the lead pump will remain energized until the "Stop" float opens. NOTE: In Duplex systems where it is considered normal for two pumps to operate in tandem during peak flow conditions, the third and fourth float may be reversed. 7. The Audible High Water Horn can be silenced by pressing the Alarm Silence Button. When the “Alarm” float opens the External High Water Light, Audible High Water Horn and Dry Auxiliary Contacts will be reset. All electrical systems must be installed by a qualified licensed electrician and according to the National Electrical Code. (See section 430-71 through 430-113 plus any others that apply) Refer to FM0712 for correct selection of Electrical Alternator. © Copyright 2006 Zoeller Co. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : mikem Create Date : 2006:03:21 15:21:09-05:00 Modify Date : 2014:04:10 11:05:03-04:00 Subject : FM0486 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : Windows NT 4.0 Metadata Date : 2014:04:10 11:05:03-04:00 Format : application/pdf Title : FM0486-Electrical Alternator Control Panel Catalog Sheet Description : FM0486 Creator : mikem Document ID : uuid:aa029ff4-7140-4511-b400-80b8f6eca9bc Instance ID : uuid:8b35eb0f-4618-4cb3-af87-dd6448a9f893 Page Count : 2EXIF Metadata provided by EXIF.tools