536913 1 Armstrong Compass Wet Rotor Circulator Brochure User Manual

536912 1 Armstrong Compass Wet-Rotor Circulator Brochure 536912_1_Armstrong Compass Wet-Rotor Circulator Brochure

User Manual: Pump 536913 1 Armstrong Compass Wet-Rotor Circulator Brochure

Open the PDF directly: View PDF PDF.
Page Count: 4

Download536913 1 Armstrong Compass Wet-Rotor Circulator Brochure User Manual
Open PDF In BrowserView PDF
compa ss
high-efficiency
wet-rotor circulators
etl

*

complies with
eei ≤ 0 . 2 2

solution outline
file no: 10.19
date: february 2014

supersedes: 10.19
date: july 2013

our choice of
circulator has
a surprisingly
large effect
on your building project.
Easy access
for wiring
the terminal
block

t

he right circulator will generate
energy savings for years. Advanced variable speed technology
increases circulator efficiency; even though
the circulator and motor are small, the energy savings can add up. Homeowners will
appreciate the reduced operating costs and
reduced carbon footprint.
For contractors, a well-designed circulator
is easy to install and will reduce or eliminate
customer complaints. For wholesalers and
contractors, a circulator that covers a broad
range of operating requirements makes the
selection process easier, leaving more time
for serving customers.
Inventory costs are also important. The right
choice of circulator lets you serve more customers and installations with only one model.
Keeping fewer circulator models on your
shelf, or in your trucks, cuts your inventory
investment and your operating costs.

for details on
• Design Envelope selections
• Demand-based variable speed operation
• Sensorless technology
please see the Design Envelope solution outline
(file no. 100.11)

kWh

energy savings
up to

70

%

esign Envelope is a revolutionary technology
pioneered by Armstrong that offers simplified circulator selection, lowest installed
cost, expanded application flexibility and optimized
energy efficiency. Armstrong Design Envelope technology, previously offered in Armstrong pumps from one
horsepower to 450 hp, is now available in Armstrong
circulators. Design Envelope technology augments the
value of Armstrong circulators through increased operating range and sensorless, demand-based control.

D

key benefits
esponding to the
need for a better circulator, Armstrong
offers compass, an advanced
solution that benefits everyone
involved in a heating system
project. By selecting the right
circulator, wholesalers, homeowners, and contractors can
all come out ahead.

R

compa s s circulators incorporate advanced functionality to assist with your construction and service
projects and improve the long-term enjoyment of the
building spaces you help create.
Easy sizing and selection of the compa ss circulator simplifies
your job as a wholesaler or contractor and reduces your
inventory requirements. 					
In the field, the front mounted terminal block reduces
installation time.						
The compa ss “auto” algorithm intelligently adapts to system
demand, so you get the right setup every time and your customers enjoy comfortable room temperatures.
		
Ultimately, compa ss circulators provide reliable performance,
backed by a two-year warranty, with noticeable reductions in
energy consumption and operating costs.

key features
Broad operating range, producing up
to 20 feet of head and 20 USgpm flow
Design Envelope technology providing
sensorless demand-based control
Efficient ecm motor technology and
intelligent variable speed operation
Easy to read display
Eight different modes of operation providing versatility to cover the performance
of a wide range of fixed speed circulators
Large wiring chamber and frontmounted terminal block

tem requirement. The pump adapts to the
e, it is recommended to leave the pump in
n at least one week before selecting other

pump. The air in the pump may cause noise but the noise
should cease after a few minutes running.
The venting process can be shortened by setting the pump to
run at speed III for a short period of time (20 seconds).

ecommended (auto) to alternative

performance

are 'slow' systems that cannot be set to the
on within minutes or hours.

ded pump setting does not give the desired
areas of the building, change the pump setting
ernative.

gs and pump performance (section 10) for
toronto

Once the pump is vented (the noise has ceased), set the pump
mode according to the recommendations (see section 7).

cautionpower r ange

5W-45W
pump must
not run
maThe
x flow
r ate
20dry.USgpm
max head pressure 20 ft
model c a st iro n : co m pa s s 2 0 -2 0 c i
item no: 1 8 0 2 0 3 - 6 0 6
9.0 pump settings and*stainle
pump performance
ss steel: co m pa s s 2 0 -2 0 s s
item no: 1 8 0 2 0 3 - 6 0 7
9.1 relation between pump setting
and pump performance

bertrand avenue
s with 23
bypass
valve between
toronto, ontario
nd return
canadapipes

compass
performance
curves
Armstrong Compass
performance curves

m1l 2p3
+1 416 755 2291

of bypass valve

22
20

head - ft.wg.

+1 716 693 8813

erenwhen used in Auto or proportional pressure
b i r mwill
i n g reduce
ham
the circulator
speed when the
mucklowishill
tem close heywood
and the wharf,
heat demand
reduced.

auto Circulator adapts to system demand over time.

18
16
14

8
6

pc3 Lowest constantpressure curve

4
2

i
0

4

2

6

8

iii

ii

0
10

12

14

16

18

20

pc4 Highest constant
pressure curve

22

flow - usgpm

i
ii

iii Highest constant speed

pressure curve

pc4

b

pc2

iii

ith liquid and properly vent the system before
p. The required minimum inlet pressure in
temperature
must be available at the pump
bangalore
n 3).
#59, first floor, 3rd main

pc2 Highest proportionalpressure curve

pc2

speed

wenlock way
manchester
kingdom
tart-upunited
m12 5jl
+44 (0) 8444 145 145

pc1

auto

10

m htiw dellatsni eb tsum rotalucriC
sc
no
irneed
tcelto
e eremove
ht dnthe
a nbypass
oitisovalve.
p latnoziroh
manchester

pc1 Lowest proportionalpressure curve

pc3

pc4

12

halesowen, west midlands
unitedsystem
kingdom
ng an existing
with a bypass valve
b62 8dj
acing a fixed
circulator
+44speed
(0) 8444
145 145 with a Compass

p

eight mode options

24

erential pressure bypass valve is to ensure
b u fcan
f a lbe
o distributed when all valves
m the boiler
93 east avenue
-heating circuits
and/or thermostatic radiator
north tonawanda, new york
d. These valves
were
commonly applied in multi
u.s.a.
14120fi-6594
th traditional
xed speed pumps.

au to
a

ii Medium constant speed

pc3

i Lowest constant speed

pc1
a = 6.375"
b = 7.08"
c = 5.31"

fig. 10 Pump setting in relation to pump performance

c

margosa road, malleswaram
bangalore, india
560 003
+91 (0) 80 4906 3555

itpo
e t u l osvh (a n g h a i

dednemmocer

no. 1619 hu hang road, xi du township
feng xian district, shanghai
p.r.c.
201401
+86 21 3756 6696

a r m s t r o n g f lu i d t e c h n o lo g y
established 1934

For more information, contact
your Armstrong representative
or visit us at:
armstrongfluidtechnology.com/
ContactUs

a r m s t r o n g f lu i d t e c h n o lo g y. c o m

tm



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:02:19 15:05:39-05:00
Metadata Date                   : 2014:02:19 15:06:33-05:00
Modify Date                     : 2014:02:19 15:06:33-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:dd9b3723-ec55-450a-842b-1c49c3ea78d0
Original Document ID            : xmp.did:F36DDB2345BDE011806689D2FE47801B
Document ID                     : xmp.id:6E9B8C22A199E3118856E32CBBA25953
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6D9B8C22A199E3118856E32CBBA25953
Derived From Document ID        : xmp.did:25440E6DD3E7E211BE53DCD3E8E8EB48
Derived From Original Document ID: xmp.did:F36DDB2345BDE011806689D2FE47801B
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:02:19 15:05:40-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu