537365 1 Laing Autocirc Instant Hot Water Pump Brochure User Manual
537366 1 Laing Autocirc Instant Hot Water Pump Brochure 537366_1_Laing Autocirc Instant Hot Water Pump Brochure
User Manual: Pump 537365 1 Laing Autocirc Instant Hot Water Pump Brochure
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
• Highly efficient ECM technology • Long lasting, silent operation • Saves thousands of gallons of water • Resistant to scale build up • No shaft, no seal • Maintenance free without blockage • Single bearing design autocirc ® INSTANT HOT WATER SYSTEM AS LITTLE AS 14 WATTS! BR-25 Get instant hot water at every faucet with as little as 14 watts! How autocirc Works The autocirc is the most efficient system, turning on only when the system needs to be replenished with hot water. The pump is installed under the sink farthest from the water heater where hot water takes the longest to arrive. No recirculation line is required. Adjustable Thermostat Models Fixed Thermostat Models • For models with the adjustable thermostat, there is an adjustable “ON” temperature range from 77ºF to 91ºF (25ºC to 33ºC). This built-in temperature sensor will turn the circulator OFF when it reaches 95ºF (35ºC) and turn the circulator ON when the temperature cools down to the “ON” temperature set point. • A built-in temperature sensor automatically turns the pump ON when water temperature in the hot water line cools down to 85°F. Water is then pumped from the hot to cold line. The autocirc pump turns OFF automatically when water temperature reaches 95°F, ensuring instant availability of shower warm water with maximum temperature hot water only seconds behind. When the pump is OFF, a built-in auto closure device prevents any other hot-to-cold line or cold-to-hot line mix. Design The autocirc has a spherical motor. The only moving part of the pump is a spherical rotor/ impeller unit which is suspended on a wear resistant ceramic ball. Laing pumps are completely shaft-less. The patented, Laing design eliminates problem shafts, seals and cylindrical bearings found on conventional, mechanically sealed canned pumps. Hot water will also be instantly available at all other faucets located on the hot water supply line between the water heater and the faucet where the autocirc is installed. No return line required! Installs within minutes, directly under the sink. Benefits • Silent during operation • Requires only one pump and one installation for all fixtures on the hot water plumbing line • Does not require a return line • Saves the average family of four thousands of gallons of water annually • Saves money and pays for itself in a short period of time Features • Built-in 24-hour timer which allows the selection of system operating periods to suit family usage • Built-in fixed thermostat or an optional, adjustable ON thermostat • Comes complete with a 6 ft. long power cord Technical Data Motor Design: Shaft-less spherical motor Input: 14 Watts Maximum Fluid Temperature: 203°F / 95°C Maximum Line Pressure: 145 PSI Compatible Fluids: Potable water Available Models Part Number Description Model Weight LHB08100092 Lead Free Brass* Autocirc 1/2” Fixed Thermostat with Timer E1-BCANCT1W-06 4 lbs. LHB08100093 Lead Free Brass* Autocirc 1/2” Adjustable “ON” Thermostat with Timer E1-BCANRT1W-06 4 lbs. *Less than 0.25% Pb by weight on wetted parts surface areas. 9/16” 24 UNEF 1 19/32” 9/16” 24 UNEF 4 3/8” Xylem, Inc. 3878 S. Willow, Suite 104 Fresno, CA 93725 Tel: (559) 265-4730 (800) 554-6853 Fax: (559) 265-4740 (800) 453-7523 www.xyleminc.com/brands/laingthermotech Laing Thermotech is a trademark of Xylem, Inc. or one of its subsidiaries. © 2012 Xylem, Inc. BR-25 July 2010 7 7/16” 1/2” 14 NPT 1/2” 14 NPT 1 7/32” 2 7/32” 4 13/32” 2 13/16” 2 13/16”
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Instance ID : uuid:1e9fad4b-58ec-c54a-90ef-f86d9fe4312a Document ID : adobe:docid:indd:eebc5cff-0c4c-11e0-ab45-e74034afca15 Original Document ID : adobe:docid:indd:eebc5cff-0c4c-11e0-ab45-e74034afca15 Rendition Class : proof:pdf Derived From Instance ID : 26523bf6-0957-11e0-a4be-e095a49a3f38 Derived From Document ID : adobe:docid:indd:ac93fc75-3d1e-11df-8e64-e3ba68188d3c History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:BCB3E33511206811871FF0760C094CB2, xmp.iid:BDB3E33511206811871FF0760C094CB2, xmp.iid:5740783013206811871FF0760C094CB2, xmp.iid:2FC86A8514206811871FF0760C094CB2, xmp.iid:4E0F1B0616206811871FF0760C094CB2, xmp.iid:560F1B0616206811871FF0760C094CB2, xmp.iid:8D079BD016206811871FF0760C094CB2, xmp.iid:8E079BD016206811871FF0760C094CB2, xmp.iid:8F079BD016206811871FF0760C094CB2, xmp.iid:90079BD016206811871FF0760C094CB2, xmp.iid:8B17532637206811871FF0760C094CB2, xmp.iid:44F7944337206811871FF0760C094CB2, xmp.iid:9CD378AE39206811871FF0760C094CB2, xmp.iid:13269B773B206811871FF0760C094CB2, xmp.iid:36DA493D092068118083FCB0FD7683DC, xmp.iid:B814F900142068118083FCB0FD7683DC History When : 2012:03:30 08:50:40-05:00, 2012:03:30 08:50:40-05:00, 2012:03:30 09:04:50-05:00, 2012:03:30 09:14:22-05:00, 2012:03:30 09:25:07-05:00, 2012:03:30 09:30:17-05:00, 2012:03:30 09:30:47-05:00, 2012:03:30 10:11:12-05:00, 2012:03:30 10:12:05-05:00, 2012:03:30 10:12:20-05:00, 2012:03:30 13:22:15-05:00, 2012:03:30 13:23:04-05:00, 2012:03:30 13:42:05-05:00, 2012:03:30 13:53:09-05:00, 2012:06:12 07:50:30-05:00, 2012:06:12 09:13:41-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Create Date : 2012:06:12 09:13:53-05:00 Modify Date : 2012:06:14 11:28:36-05:00 Metadata Date : 2012:06:14 11:28:36-05:00 Creator Tool : Adobe InDesign CS5 (7.0) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 8211 bytes, use -b option to extract), (Binary data 7798 bytes, use -b option to extract) Doc Change Count : 330 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 4 Creator : Adobe InDesign CS5 (7.0)EXIF Metadata provided by EXIF.tools