537424 1 Zoeller Waste Mate 290 Series Pump Brochure User Manual

537422 1 Zoeller Waste-Mate 290 Series Pump Brochure 537422_1_Zoeller Waste-Mate 290 Series Pump Brochure

537423 1 Zoeller Waste-Mate 290 Series Pump Brochure 537423_1_Zoeller Waste-Mate 290 Series Pump Brochure

User Manual: Pump 537424 1 Zoeller Waste-Mate 290 Series Pump Brochure

Open the PDF directly: View PDF PDF.
Page Count: 4

SECTION: 2.30.050
FM0450
0414
Supersedes
1013
COMPARE THESE FEATURES
Non-clogging vortex impeller design. Bronze class
C89833
Durable cast construction. Cast iron switch case, base,
motor and pump housing. No sheet metal parts
to rust or corrode. All cast iron class 30 30,000#
tensile strength
• Stainlesssteelscrews,bolts,oatrod,handle,guard,
arm and seal assembly
20' UL listed 3-wire neoprene cord and plug. Extra cord
lengths available in 25'-35'-50' lengths only.
3 phase models available
• Motor-60Hz,3450RPM,oil-lled,hermeticallysealed,
automatic reset, thermal overload protected (1 Ph only)
Maximum temperature for sewage or dewatering
130°F (54°C), 120°F (49°C) for WD295. If over 130°F,
consult factory.
Shaft seal - stainless steel carbon & ceramic rotary
• Corrosionresistantpowdercoatedepoxynish
Upper & lower ball bearings running in bath of oil
Square ring & gasket - neoprene
All models pass 2" spherical solids
Major width 12-7/8" • Height 19-5/16" (single seal)
• Automaticunitsavailablewithoatoperated,
submersible 2-pole mechanical switch.
On
point 15-3/4"
- Off point 5-1/4"
• Specify2"or3"NPTfemaleangedverticaldischarge.
100% computerized testing
MODELS 4292-4293-4294-4295
DOUBLE SEAL PUMPS (nonautomatic only)
Gives motor extra protection from seal leaks
Improved bearing lubrication
Helps eliminate seal and bearing damage from dry runs
Major width 12-7/8" Height 21-3/16"
Note: The sizing of efuent systems normally requires
variable level oat(s) controls and properly sized
basins to achieve required pumping cycles or dosing
timers with nonautomatic pumps.
© Copyright 2014 Zoeller Co. All rights reserved.
292 - 293 - 294 - 295 Single Seal Series
4292 - 4293 - 4294 - 4295 Double Seal Series
(For Pump Prex Identication see News & Views 0052)
HIGH HEAD
“WASTE-MATE”
SUBMERSIBLE
SEWAGE
OR DEWATERING PUMP
Double
Seal
Pump
Nonautomatic
models for
variable level
systems
Automatic units
available in
single phase 292,
293, 294 & 295
series
WD295 controlled
by variable level
oatswitch
*See back page for UL & CSA listings
Tested to UL
Standard UL778
R
L
U
*
*
R
Certied to CSA
Standard C22.2 No.108
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
®
Your Peace of Mind is Our Top Priority
®
SK1415
SELECTION GUIDE
1. Integraloatoperatedmechanicalswitch,noexternalcontrolrequired.
2. For automatic use single piggyback variable level oat switch or
doublepiggybackvariableleveloatswitch.RefertoFM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel.
Single Seal Auto Design Weight 86-89 lbs.
For information on additional Zoeller products refer to catalog on explosion-proof models, FM1702; Simplex controls,
FM1596; Piggyback Variable Level Float Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator,
FM0495; Sump/Sewage Basins, FM0487; Alarm Systems, FM0732; Disconnect/Rail Systems, FM0787; and Junction
Boxes FM1597.
CAUTION
All installation of controls, protection devices and wiring should be done by a qualied licensed electrician. All electrical and
safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and
Health Act (OSHA).
© Copyright 2014 Zoeller Co. All rights reserved.
PUMP PERFORMANCE CURVE
MODEL 292/4292/293/4293/294/4294/295/4295
0 80 160 240 320 400 480
220140130120110100908070605040302010
0
2
4
6
8
10
12
14
16
18
20
80
65
60
55
50
45
40
35
30
25
20
15
10
5
LITERS
GALLONS
FEET
METERS
TOTAL DYNAMIC HEAD
FLOW PER MINUTE
150 160 170 180 190 200 210
560 640 720 800
70
22
292/4292
293/4293
294/4294
295/4295
75
24
CAUTION
Model 293 should not
be subjected to less
than 15' TDH.
009919A
Double Seal Design / Weight 92-95 lbs.
294/4294
Gal. Liters
196 742
181 685
165 625
150 568
136 515
121 458
94 356
58 220
13 49
-- --
62 ft.(18.9m)
292/4292 293/4293
199 753
115
23
89
59
154
140
184
168
435
87
337
223
583
530
696
636
295/4295
Gal.
214 810
Liters
75 ft.(22.9m)
MODEL
Feet Meters Gal. Liters Gal. Liters
5 1.5 530140 -- --
10 3.0 469124 -- --
4.6 409108 118 44715
6.1 34491 108 40920
7.6 28475 96 36325
9.1 21256 82 310
30
12.2 3810 48 182
40
15.2 ---- -- --50
18.3 ---- -- --60
21.3 ---- -- --70
Shut-off Head: 42 ft.(12.8m) 50 ft.(15.2m)
2" NPT
OR
3" NPT
AVAILABLE IN A FLANGE
19 5/16" [491 mm]
6" [152 mm]
4 1/8" 8 3/4"
6 1/2"
4 1/8" [105 mm]
6 11/32" [161 mm]
[165 mm]
[222 mm]
[105 mm]
SK863
6 [152 mm]
4 1/8 8 3/4
6 1/2
4 1/8 [105 mm]
21 3/16 [538 mm]
4 1/8 [105 mm]
2" NPT
OR
3" NPT
AVAILABLE IN A FLANGE
[165 mm]
[222 mm]
[105 mm]
009919B
* No molded plug ** Single piggyback switch included (1) UL listed unit available with 20 amp plug (2) CSA approval with 20 amp plug
292 MODELS 4292 MODELS Standard all models - 20 ft. cord - ½ HP Control Selection Listings
Single Seal Double Seal Volts Ph Mode Amps Simplex Duplex cCSAus UL
M292 -- 115 1 Auto 15.0 1 -- Y Y(1)
N292 N4292 115 1 Non 15.0 2 or 3 2 or 4 Y Y(1)
D292 -- 230 1 Auto 7.5 1 -- Y N
E292 E4292 230 1 Non 7.5 2 or 3 4 Y N
* H292 -- 200 1 Auto 8.8 1 -- Y N
* I292 * I4292 200 1 Non 8.8 2 or 3 4 Y N
* F292 * F4292 230 3 Non 5.2 3 4 Y N
* J292 * J4292 200 3 Non 6.4 3 4 Y N
* G292 * G4292 460 3 Non 2.9 3 4 Y N
* BA292 * BA4292 575 3 Non 2.4 3 4 Y N
293 MODELS 4293 MODELS Standard all models - 20 ft. cord - 1 HP Control Selection Listings
Single Seal Double Seal Volts Ph Mode Amps Simplex Duplex cCSAus UL
D293 -- 230 1 Auto 10.2 1 -- Y Y
E293 E4293 230 1 Non 10.2 2 or 3 4 Y Y
* H293 -- 200 1 Auto 12.0 1 -- Y N
I293 I4293 200 1 Non 12.0 2 or 3 4 Y N
* F293 * F4293 230 3 Non 7.6 3 4 Y Y
* J293 * J4293 200 3 Non 8.2 3 4 Y Y
* G293 * G4293 460 3 Non 4.0 3 4 Y Y
* BA293 -- 575 3 Non 3.3 3 4 Y N
295 MODELS 4295 MODELS Standard all models - 20 ft. cord - 2 HP Control Selection Listings
Single Seal Double Seal Volts Ph Mode Amps Simplex Duplex cCSAus UL
D295 -- 230 1 Auto 17.1 1 -- Y(2) Y
E295 E4295 230 1 Non 17.1 2 or 3 4 Y (2) Y
WD295 -- 230 1 Auto 17.1 ** 4 Y N
* H295 -- 200 1 Auto 20.5 1 -- Y N
* I295 * I4295 200 1 Non 20.5 2 or 3 4 Y N
* F295 * F4295 230 3 Non 12.2 3 4 Y Y
* J295 * J4295 200 3 Non 14.3 3 4 Y Y
* G295 * G4295 460 3 Non 6.1 3 4 Y Y
* BA295 -- 575 3 Non 4.9 3 4 Y N
294 MODELS 4294 MODELS Standard all models -20 ft. cord -1½ HP Control Selection Listings
Single Seal Double Seal Volts Ph Mode Amps Simplex Duplex cCSAus UL
D294 -- 230 1 Auto 13.7 1 -- Y Y(1)
E294 E4294 230 1 Non 13.7 2 or 3 4 Y Y(1)
* H294 -- 200 1 Auto 17.8 1 -- Y N
* I294 * I4294 200 1 Non 17.8 2 or 3 4 Y N
* F294 * F4294 230 3 Non 9.5 3 4 Y Y
* J294 * J4294 200 3 Non 10.8 3 4 Y Y
* G294 * G4294 460 3 Non 4.8 3 4 Y Y
* BA294 -- 575 3 Non 3.8 3 4 Y N
© Copyright 2014 Zoeller Co. All rights reserved.
© Copyright 2014 Zoeller Co. All rights reserved.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
®
®visit our web site: