539123 1 Zoeller Basement Sentry Repair Parts

539123 1 Zoeller Basement Sentry I Installation Manual 539123_1_Zoeller Basement Sentry I Installation Manual 539123_1_Zoeller Basement Sentry I Installation Manual pdf pumpproducts

539123 1 Zoeller Basement Sentry Installation Manual 539123_1_Zoeller Basement Sentry Installation Manual 539123_1_Zoeller Basement Sentry Installation Manual pdf pumpproducts

: Pump 539123 1 Zoeller Basement Sentry Repair Parts 539123_1_Zoeller Basement Sentry Repair Parts pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

Download539123 1 Zoeller Basement Sentry Repair Parts
Open PDF In BrowserView PDF
FM1311
1114
Supersedes
0114

Your Peace of Mind is Our Top Priority ®
®

MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:
www.zoeller.com

Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/

®

P/N 009132

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.

®

MODEL 507

12 VOLT DC BATTERY BACKUP PUMP
PREINSTALLATION CHECKLIST
1.	 Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.
2.	 Read all the installation instructions regarding installing and start up. Retain for future reference.

SEE BELOW FOR
LIST OF WARNINGS

1.	 Testing for Ground. As a safety measure each electrical outlet should
be checked for ground using an Underwriters Laboratory listed circuit
analyzer, which will indicate if the power, neutral and ground wires are
correctly connected to your outlet. If they are not, call a qualified, licensed
electrician.
2.	 For your protection always disconnect the power supply from its power
source before handling the components of your DC backup pump or the
primary pump.
3.	 Installation and checking of electrical circuits and hardware should be
performed by a qualified, licensed electrician.
4.	 All electrical and safety codes must be followed in addition to the National
Electrical Code and all applicable local codes.
5. 	

It is the owner’s responsibility to check the battery and battery
connection at least once a month. Batteries contain acid and
caution must be taken when handling.

6.	 Risk of electric shock - These pumps have not been investigated for use
in swimming pool areas.
7.	 According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and birth
defects or other reproductive harm.

CAUTION

SEE BELOW FOR
LIST OF CAUTIONS

1.	 Make sure there is a properly grounded 115V receptacle available. Do
not use primary pump circuit. The location must be within 6' of the control
box and battery. The power supply for your DC control system plugs
directly into the 115V outlet. DO NOT USE AN EXTENSION CORD.
2.	 Make sure the 115V electrical supply circuit is equipped with fuses or
circuit breakers of proper capacity.
3.	 DC emergency pumps are designed for handling clear water. Do not use
in septic tanks to pump effluent or sewage pits to pump sewage.
4.	 Repair and service of your DC backup system should be performed by
an authorized service station.
5.	 The installation of DC automatic backup pumps requires the use of a
variable level float switch for operation. It is the responsibility of the
installing party, to ensure that the float switch will not hang up on the
pump apparatus or pit peculiarities and is secured so the pump will turn
“on” and “off”. It is recommended that the pit be 18" in diameter or larger
to accommodate both a primary and a DC backup pump.

Turbulence caused by high velocity incoming water
CAUTION
can cause the DC pump to airlock. If this condition exists, the
incoming water must be baffled to avoid excessive turbulence.

REFER TO WARRANTY ON PAGE 2.
© Copyright 2014 Zoeller® Co. All rights reserved.

LIMITED WARRANTY
Manufacturer warrants, to the purchaser and subsequent owner during the
warranty period, every new product to be free from defects in material and
workmanship under normal use and service, when properly used and maintained,
for a period of one year from date of purchase by the end user, or 18 months
from date of original manufacture of the product, whichever comes first. Parts
that fail within the warranty period, one year from date of purchase by the
end user, or 18 months from the date of original manufacture of the product,
whichever comes first, that inspections determine to be defective in material or
workmanship, will be repaired, replaced or remanufactured at Manufacturer's
option, provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No allowance
will be made for shipping charges, damages, labor or other charges that may
occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any
material or product that has been disassembled without prior approval of
Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident
or uncontrollable act of nature; that has not been installed, operated or
maintained in accordance with Manufacturer's installation instructions; that has
been exposed to outside substances including but not limited to the following:
sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil,

gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels
or feminine sanitary products, etc. in all pumping applications. The warranty
set out in the paragraph above is in lieu of all other warranties expressed or
implied; and we do not authorize any representative or other person to assume
for us any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,
Attention: Customer Support Department to obtain any needed repair or
replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF
EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so
the above limitation may not apply to you. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.

Note: The purchase of an Aquanot ® Battery from Zoeller Pump Company will extend the Limited Warranty to three years from date of installation.
Note: Three year limited warranty valid only when a complete system is purchased and used as a backup to a primary dewatering system. A complete system
includes a Model 507 Basement Sentry ® and an Aquanot ® Battery.

MAINTENANCE
1.	
	
	
	
	
	
	

Inspect and test the system for proper operations at least every 3 months.*
(a)	 Red power on indicator light should be “on” indicating AC power
is on.
(b)	 Unplug primary pump and the control charger from power supply.
(c)	 Fill sump with water to the “on” level for the DC pump. Allow pump
to run a few minutes.
(d)	 The alarm will sound approximately 3 seconds after the pump
starts to run.
(e)	 Push alarm reset switch. The alarm will go “off”.
(f)	 Pump will shut off after water level is lowered and the float drops
to the off position.

2.	 Plug the control charger and the primary pump into the wall outlet.
	
(a)		The primary pump will come on and lower the water to the
			normal operating level and shut off.
	
(b)		The “yellow” charging light should be on. The charger is replacing
the energy consumed during the test. The “green” light will come on
after the charger has replaced the energy consumed during the test.
* Wet cell batteries should be checked every month.

TROUBLESHOOTING INFORMATION
1.	
	
	
	
	
2.	
	

DC Pump won’t run.
(a)	 Check 15 amp fuse in line from pump to switch (see fig. 3). If fuse
is blown, replace with 15 amp Littelfuse type 3AG, series 311.
(b)	 Check for proper connections.
(c)	 Check all wire terminal points. Clean if required.
(d)	 Check for low battery. Service battery if required.

Pump runs but pumps very little or no water.
(a) 	Check for low battery. Battery will recharge if Red power “on”
light indicates power has been restored and the float switch is
in the off position.
	
(b)	 If immediate usage is required, remove and replace dead
battery with a full recharged battery.
	
(c)	 Due to varying conditions the pump may continue to run on a
low battery without sufficient power to remove water. Pump will
not stop running until battery is completely discharged.
	(d)	CAUTION Weak batteries can be recharged but may not
store sufficient energy for full service. A weak recharged battery
can only be detected by reduced pumping time or by checking
each cell with a hydrometer. If your emergency pump system
is used frequently the battery should be checked by a qualified
battery dealer.

3.	
	
	

Pump cycles too frequently.
(a)	 Check positions of rubber stops on float rod.
(b)	 Adjust upper rubber float stop as required. Recommended for
standard installation.

4.	
	

Float switch in “on” position. Pump won’t run.
(a)	 Check for obstruction in pump preventing impeller from rotating.

5.	
	

Pump runs, but pumps water intermittently.
(a)	 Pump is air locking. Check flow of water incoming to sump. If
water is entering the sump at a high velocity creating a turbulent
condition, a mixture of air and water may cause a complete
or partial air lock and reduce or stop the flow of water in the
discharge pipe.
(b)	 Baffle the incoming stream of water to reduce turbulence.
Diverting water stream against wall of basin usually corrects an
air lock problem.

	

NOTE: When running the primary pump, it is normal for a stream of water to
spray out of the 1/8" air relief hole.
6.	 Water level stays high. DC Pump continues to run.
	 (a)	 Battery is low.
	 (b)	 If power has been restored and water in sump remains high check
primary pump. Service if required.
	 (c)	 After several hours the battery will be restored to full charge.

© Copyright 2014 Zoeller® Co. All rights reserved.
2

TROUBLESHOOTING INFORMATION, continued
7.	 Alarm sounds during battery recharge cycle.
	 (a)	 Push alarm reset (max. 3 times). If condition persists, replace battery.

	

(b)	 To silence alarm if alarm will not reset, unplug the charger from
115V wall outlet, then disconnect the black lead from charger on
negative (-) battery post. Check battery. Replace if necessary.
Reconnect and refer to Installation (step 12).

DESCRIPTION
The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The
DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system
is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.

REPLACEMENT PARTS LIST
MODELS:
ITEM

DESCRIPTION

QTY

507-C

507-D

507-E

507-F

4/96
thru
10/05

11/05
thru
9/11

10/11
thru
10/13

11/13
thru
Current

1

DC backup pump

1

017198

017198

017198

017198

2

Plastic battery box and cover

1

10-0764

10-0764

10-0764

10-0764

3

DC control charger with terminals

1

152899

152899

152899

152899

4

“Off”/”On” float switch

1

017197

017197

017197

017197

5

1½" x 5" long PVC pipe nipple

1

005639

N/A

N/A

N/A

6

Check valve

(2) REV C - (1) REV D

005636

005636

019768

019768

7

Reducer hose coupling and clamp

1

30-0188

N/A

N/A

N/A

8

1¼" x 1" PVC reducer fitting

1

005642

N/A

N/A

N/A

9

1" pipe to hose adapter elbow

1

005643

N/A

N/A

N/A

10

1" hose coupling and two clamps

1

005703

N/A

N/A

N/A

11

1½" PVC pipe tee

1

005645

005645

005645

005645

12

1½" 90 degree PVC pipe elbow

1

005644

N/A

N/A

N/A

13

1¼" x 1¼" PVC coupling

1

009129

N/A

N/A

N/A

14

Pump mounting kit, includes brkt, S.S. worm drive
clamp, two #10-24 screws and washers.

1

005704

N/A

N/A

N/A

15

Cable tie

1

005868

N/A

N/A

N/A

16

Anchors, wall

2

009691

009691

009691

N/A

17

Bracket, control mounting

1

007779

007779

007779

N/A

18

1½" x 1½" PVC coupling

1

N/A

009746

N/A

N/A

19

Clamp, H28 SS / zinc-plated screw

1

012724

012724

012724

012724

20

Fuse, AGC - 15 amp

1

N/A

012352

012352

012352

19
4

BATTERY SELECTION

20

1

The DC emergency pump system requires a good quality, 12 volt
battery to obtain maximum pumping time during a power outage.
A deep-cycle, 12 volt, 105 amp-hour marine battery or larger is
recommended and will provide approximately 7½ hours of continuous
pumping time in a sump pump installation with 8' of head pressure. In
most installations the pump runs intermittently and the battery life is
extended accordingly. Batteries with top terminals are recommended
for ease of installation. These batteries contain acid and proper
precaution must be taken when handling. Maximum battery size
13½" length x 7" width x 9½" height.

3

11

6

2

12 VOLT BATTERY
SUPPLIED BY USER

SK2981

© Copyright 2014 Zoeller® Co. All rights reserved.
3

PERFORMANCE

The DC pump performance with fully charged 12V battery
Discharge: Feet of Head

5

10

15

17.5

Flow: Gal. per Min.

23

15

5

Shut-off Head

The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery after use when AC power
is restored. Time for recharge depends upon the amount of power consumed by the pumping cycle during the AC power interruption. The pump may
go back to the ready run position in a very short period of time. A completely drained battery may require up to 24 hours for full recharge. If battery
does not charge properly, the LCD will display BATFAIL and the alarm will sound.

INSTALLATION
	 1.	 The preferred method of installation for backup pumps is shown in
Figures 1 and 2. The installation kit includes the necessary fittings and
one check valve for installing with the backup pump discharging into the
primary pump outlet pipe. An additional check valve is incorporated in the
discharge of the backup pump.
		 NOTE: Do not install in small spaces where the charger will not be
properly cooled.
	 2.	 Remove all parts from shipping carton and make sure all parts are
included. Refer to checklist on page 3.
	 3.	 Select location for battery and control charger. Control charger must be
within 6' of a 115V wall outlet and within 6' of pump and basin. Connect to
a separate circuit, different than the primary pump.
	 4.	 If primary pump is installed, disconnect power.
		 NOTE: Discharge piping must be 1-1/2" SCH 40 PVC
	 5.	 Remove the discharge pipe from the pump and put to the side.
	 6.	 Solvent weld DC pump to tee at a 30 degree angle as shown in Figure 4.
	 7.	 Install in-line check valve into primary pump discharge.
	 8.	 Determine the position of the DC pump and measure between the inline check valve and tee. Use that measurement to cut discharge pipe.
Solvent weld that piece first to the tee. Measure, cut & solvent weld any
remaining discharge piping above the tee. Finally, connect the discharge
pipe to the in-line check valve and tighten hose clamp. See Figure 4..
		 NOTE: Check float operations to ensure the hose clamp screws do not
interfere with the float operation of the primary pump.
	 9.	 Assemble the float assembly per figure 5.
	10.	 Install the float switch assembly bracket above the outlet tee using the
clamp provided (see figures 1 and 2). Make certain the clamp is tight on
the pipe to avoid slippage. Use electrical tape below the clamp to help
prevent the clamp from moving. Ensure that the “off” level of the float is 1"
min. above the discharge tee of the DC backup pump (see figures 1 and
2). Position pumps in the sump and move float up and down, making sure
of free movement without interference from any obstructions inside the
sump or lid. Very shallow sumps may require some adjustment to avoid
overfilling or backing up of water into the sump inlet. The float switch can

be moved on the discharge pipe or the rubber stops can be adjusted as
necessary. Cut extra float rod length below lower float stop to prevent
debris from interfering with float operation.
	11.	 Install DC charger (see figure 3) by using anchors provided. If more
convenient, the charger may be set on a nearby shelf or ledge. The
charger should be located 3 or 4 ft. above the sump. Then, remove
protective screen from the front of the charger.
	12.	 Connect the leads from the control charger to the battery terminals.
Positive (+) lead to positive terminal and black neg. (-) lead to negative
battery terminal. Upon proper connection, test alarm will momentarily
sound. This indicates proper charger to battery connection.
CAUTION
Correct battery hook up is essential for operation of
the system. Use wing nuts supplied with battery and eyelet connectors
on battery wire leads. The positive terminal is the larger stud, 3/8"
diameter. The smaller stud, 5/16" diameter is the negative terminal.
Apply grease to the terminals to help prevent corrosion.
	13.	 Connect the black lead from the pump to the negative (-) battery
terminal. Connect the white lead from the pump to the white lead
from the switch. This connection is made at the fuse installed on the
switch wire (see figure 3). Connect the black lead from the switch to the
positive (+) battery terminal.
	14.	 Connect the green sensor wire to the sensor connector (figure 3).
	15.	 Close battery box and secure cover. Carpeted or wood barrier between
the battery case and the floor is recommended.
	16.	 Plug the charger's cord into charger and the 115V wall outlet. The primary
sump pump and the control box should be on separate circuits.
	17.	 Reconnect power to primary sump pump.
	18.	 Optional: A dongle may be used to input a name and number into the
charger for service information to the end user.
	19.	 Optional: On the bottom of the charger there is a pair of dry contacts
to signal an auxiliary device of a low battery, high water and reverse
polarity alarm condition. This simple 2-wire connection is rated at a
maximum of 24V AC/DC and 0.5 amps. It can be used with an autodialer (such as the Zoeller 10-2616), alarm or home security system.
Read the auxiliary equipment's documents for further instructions.

INITIAL START-UP AND OPERATION

	 1.	 Test the installation for leaks by running water into the sump allowing
for normal operation of the primary pump.
	 2.	 Check the control charger. The “red” power on light will be lit when the
unit is plugged into the 115V wall outlet. The charged/charging lights will
indicate the condition of the battery when the charger has AC power.
	 3.	 Disconnect primary pump before touching any component in the sump pit.
	 4.	 Lift float switch. The DC backup pump will run and the alarm will sound.
Lower float switch immediately after alarm has sounded. Pump is running
dry during initial check for several seconds.
CAUTION Continuous
dry running may cause overheating and damage the pump seals. Upon
release of the float switch, the pump will shut off. Press the reset button
to turn the alarm off.
	 5.	 Complete the final testing of your installation by ensuring the primary pump
is still disconnected from the power. Then, unplug the charger from the

115V wall outlet. Run water into the sump until the DC backup pump
is activated by the float switch. Check all connections for leaks.

		NOTE: When running the primary pump, it is normal for a stream of
water to spray out of the 1/8" air relief hole.
	 6.	 Push alarm reset switch when pump is running. This will silence the alarm.
The pump will continue to run.
	 7.	 Reconnect the charger and your primary pump to the AC wall outlets. The
primary pump should come on and lower the water level in the sump
back to the normal operating level and shut off. Use the alarm reset
button to reset the high water light. Both primary and backup systems
are now ready for use.
	 8.	 The battery charged and charging LED’s will alternate during normal
charging operation.
		 NOTE: See page 7 for a description of charger functions.

© Copyright 2014 Zoeller® Co. All rights reserved.
4

© Copyright 2014 Zoeller® Co. All rights reserved.
5
SK2499

BATTERY BOX

FIGURE 1

NOTE: Pump must be mounted on a 30º angle to avoid airlocking
NOTE: The section of pipe below the tee determines the height of the DC pump. A shorter
piece of pipe may be beneficial in some installations. This drawing is dimensioned for clarity.

VERIFY WEEP HOLE IS PRESENT
IN MAIN DISCHARGE LINE.
(SEE PUMP INSTALLATION
INSTRUCTIONS)

1" MIN.

IMPORTANT: OFF LEVEL
OF FLOAT ASSEMBLY
MUST BE HIGHER THAN
DC BACKUP PUMP

PRIMARY
PUMP
OUTLET

ASSEMBLY WITH SUBMERSIBLE PUMP

SK2500

IMPORTANT: OFF LEVEL
OF FLOAT ASSEMBLY
MUST BE HIGHER THAN
DC BACKUP PUMP
1" MIN.

FIGURE 2

NOTE: Pump must be mounted on a 30º angle to avoid airlocking
NOTE: The section of pipe below the tee determines the height of the DC pump. A shorter
piece of pipe may be beneficial in some installations. This drawing is dimensioned for clarity.

BATTERY BOX

PRIMARY
PUMP
OUTLET

ASSEMBLY WITH COLUMN PUMP

EXPLODED VIEW - DC PUMP
CLAMP
15 AMP FUSE

FLOAT SWITCH

WHITE LEAD
TO DC PUMP

DC BACK-UP PUMP

BLACK LEAD
TO POSITIVE

DC CHARGER

GREEN LEAD
TO FLOAT SWITCH

WHITE LEAD TO FLOAT

SPLICER

WHITE LEAD TO POSITIVE
BLACK LEAD
TO NEGATIVE

12 VOLT
MARINE BATTERY
SUPPLIED BY USER

BATTERY BOX

BLACK LEAD
TO NEGATIVE

SK2501

FIGURE 3

PUMP ASSEMBLY
IMPORTANT:
MAKE SURE THIS LINE IS
GLUED IN POINTING UP.

1

11

TOP VIEW
DISCHARGE PIPE
(SUPPLIED BY CUSTOMER)
6

FIGURE 4
© Copyright 2014 Zoeller® Co. All rights reserved.
6

SK2502

FLOAT SWITCH

CONTROL CHARGER
LCD

AC POWER

LOW BATTERY
SCROLL
ALARM RESET

R

R

ALARM OFF
POSITIVE LEAD

CHARGED
HIGH WATER

LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.

ALARM
CONTACTS

CHARGING
GROUNDED POWER CORD

GREEN LEAD
TO FLOAT SWITCH
NEGATIVE LEAD

FIGURE 5

SK2503

FIGURE 6

LCD DISPLAY AND KEYPAD FUNCTIONS
There are two buttons on the front of the charger:
•	 The scroll button is used to cycle through the information on the LCD screen.
•	 The alarm reset button:
	 ° Can be pressed to clear alarm buzzer, light and/or display.
	 ° Can be held for longer than 3 seconds to silence the buzzer for a 24-hour period.
The LCD screen will display information about the system by simply hitting the scroll button:
•	 The bottom line of the LCD will always display the battery voltage and current going to the battery, if charging.
•	 The alarm screen shows current alarms.
•	 The cycle counter screen shows how many times the DC float has been activated.
•	 The AC power loss counter screen shows how many times the AC power has been removed from the charger.
•	 Optional: a screen may also show the name and number of a service provider.
The 6 LED lights also display information about the charger at a glance:
•	 The red AC power light will be on if AC power is connected, and it will blink if AC power is not connected.
•	 The green charged light indicates a full battery, ready for operation.
•	 The yellow charging light indicates power going to the battery.
•	 The red low battery light blinks when the battery is below 10.8 volts and rapidly blinks when the battery is below 8.4 volts.
•	 The yellow high water light will blink when the float is activated, and becomes solid after 3 seconds.
NOTE: The pump should be running when the float is activated.
•	 The yellow alarm off light indicates the buzzer is currently silenced.

© Copyright 2014 Zoeller® Co. All rights reserved.
7

SK2958

THE AQUANOT ® BATTERY
There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged
and may damage the charging circuits of the Control. It is for this reason that Zoeller offers its own line of batteries. We offer both a Water/Acid Deep-Cycle
Battery and maintenance-free AGM battery which can run the pump continuously for over 7½ hours. These times are based on continuous pumping at 10' of
static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery.
Follow these recommendations:
•	
•	
•	
•	
•	

Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger.
Do NOT use a “maintenance-free” battery unless it is a Gel-filled or AGM battery.
Replace your battery every 3 years.
Do not let corrosion build up on the battery terminals.
To check specific gravity, follow the instructions on a hydrometer (not applicable for Gel or AGM batteries).

PROTECT YOUR WARRANTY:
•	 Water level in batteries must be checked once a month (not applicable for gel or AGM batteries).

CARBON MONOXIDE DETECTORS
Whether you have a “Basement Sentry®” Backup Pump System, or a competitive brand, all use batteries that give off gaseous by-products when charging.
Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent
false activation, Zoeller Company recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior.
Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede
the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer.
If the audible alarm associated with your CO detector is activated, we recommend the following actions:
1)	

Take immediate action for personal safety as recommended in the CO detector literature.

2)	

Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas.

3)	

If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the CO detector to
activate. Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation.

®

MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

Your Peace of Mind is Our Top Priority ®
© Copyright 2014 Zoeller® Co. All rights reserved.

visit our web site:
www.zoeller.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:11:18 13:46:01-05:00
Modify Date                     : 2014:11:18 13:46:04-05:00
Metadata Date                   : 2014:11:18 13:46:04-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Version ID                      : 1
Instance ID                     : uuid:0b251581-fcb4-46b9-b1f8-190d59ec3623
Original Document ID            : adobe:docid:indd:eb0f2a49-1883-11de-b89b-8d5d34673394
Document ID                     : xmp.id:6D7A01804C6FE4118B30F312646231AA
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:E61C2CDF2665E4118991E36E6D1F05E2
Derived From Document ID        : xmp.did:FBA50CB8848AE311B5F1CD88BC9309C2
Derived From Original Document ID: adobe:docid:indd:eb0f2a49-1883-11de-b89b-8d5d34673394
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:11:18 13:46:01-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu