1 543455 3 Liberty XFL70 Explosion Proof Pump Curves

: Pump 543455 3 Liberty Xfl70 Explosion Proof Pump Curves 543455_3_Liberty XFL70 Explosion Proof Pump Curves pdf

Open the PDF directly: View PDF PDF.
Page Count: 6

XFL70-P1 R11/22/2015 ©Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Pump Specifications
XFL70 Series
¾ HP Submersible Effluent Pump
For Hazardous Locations
Class 1, Division 1 Groups C & D
Class 1, Zone 1 and Groups IIA & IIB
0
2
4
6
8
10
12
14
050 100 150 200 250 300 350 400 450
0
5
10
15
20
25
30
35
40
45
50
020 40 60 80 100 120
HEAD (METERS)
FLOW RATE (LPM)
Head (feet)
Flow Rate (GPM)
XFL70
XFL70-P2 R11/22/2015 ©Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
XFL70-Series Dimensional Data
XFL70-P3 R11/22/2015 ©Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
XFL70-Series Electrical Data
MODEL HP IMPELLER VOLTAGE PHASE FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
THERMAL
OVERLOAD
TEMP
STATOR
WINDING
CLASS
CORD
LENGTH
FT
DISCHARGE
NPT
XFL71M-2 3/4 CAST IRON 115 1 15
66
120˚C/248˚F F 25
1-1/2” & 2”
XFL71M-3 3/4 CAST IRON 115 1 15
66
120˚C/248˚F F 35
1-1/2” & 2”
XFL72M-2 3/4 CAST IRON 208/230 1 9
33.6
105˚C/221˚F F 25
1-1/2” & 2”
XFL72M-3 3/4 CAST IRON 208/230 1 9
33.6
105˚C/221˚F F 35
1-1/2” & 2”
XFL73M-2 3/4 CAST IRON 208/230 3 6
33.5
105˚C/221˚F F 25
1-1/2” & 2”
XFL73M-3 3/4 CAST IRON 208/230 3 6
33.5
105˚C/221˚F F 35
1-1/2” & 2”
XFL74M-2 3/4 CAST IRON 440-480 3 3
33.5
105˚C/221˚F F 25
1-1/2” & 2”
XFL74M-3 3/4 CAST IRON 440-480 3 3
33.5
105˚C/221˚F F 35
1-1/2” & 2”
XFL75M-2 3/4 CAST IRON 575 3 2.5
12.8
105˚C/221˚F F 25
1-1/2” & 2”
XFL75M-3 3/4 CAST IRON 575 3 2.5
12.8
105˚C/221˚F F 35
1-1/2” & 2”
XFL71BM-2 3/4 BRONZE 115 1 15 66 120˚C/248˚F F 25
1-1/2” & 2”
XFL71BM-3 3/4 BRONZE 115 1 15 66 120˚C/248˚F F 35 1-1/2” & 2”
XFL72BM-2 3/4 BRONZE 208/230 1 9 33.6 105˚C/221˚F F 25
1-1/2” & 2”
XFL72BM-3 3/4 BRONZE 208/230 1 9 33.6 105˚C/221˚F F 35
1-1/2” & 2”
XFL73BM-2 3/4 BRONZE 208/230 3 6 33.5 105˚C/221˚F F 25 1-1/2” & 2”
XFL73BM-3 3/4 BRONZE 208/230 3 6 33.5 105˚C/221˚F F 35
1-1/2” & 2”
XFL74BM-2 3/4 BRONZE 440-480 3 3 33.5 105˚C/221˚F F 25
1-1/2” & 2”
XFL74BM-3 3/4 BRONZE 440-480 3 3 33.5 105˚C/221˚F F 35 1-1/2” & 2”
XFL75BM-2 3/4 BRONZE 575 3 2.5 12.8 105˚C/221˚F F 25 1-1/2” & 2”
XFL75BM-3 3/4 BRONZE 575 3 2.5 12.8 105˚C/221˚F F 35 1-1/2” & 2”
LIBERTY PUMPS CONTROL INFORMATION
PUMP MODEL
CAPACITOR
SIMPLEX
PANEL
DUPLEX
PANEL CAP KIT
XFL71M-2 XFL71BM-2 50uf ISS24LC1=3 ISD24LC2=3 K001515
XFL71M-3 XFL71BM-3 50uf ISS24LC1=3 ISD24LC2=3 K001515
XFL72M-2 XFL72BM-2 45uf ISS24LC1=3 ISD24LC2=3 K001514
XFL72M-3 XFL72BM-3 45uf ISS24LC1=3 ISD24LC2=3 K001514
XFL73M-2 XFL73BM-2 N/A ISS34=3-171 ISD34=3-171 N/A
XFL73M-3 XFL73BM-3 N/A ISS34=3-171 ISD34=3-171 N/A
XFL74M-2 XFL74BM-2 N/A ISS34=3-141 ISD34=3-141 N/A
XFL74M-3 XFL74BM-3 N/A ISS34=3-141 ISD34=3-141 N/A
XFL75M-2 XFL75BM-2 N/A ISS54=3-151 ISD54=3-151 N/A
XFL75M-3 XFL75BM-3 N/A ISS54=3-151 ISD54=3-151 N/A
Note: Liberty Pumps ISS and ISD Series control panels include intrinsically safe float circuits for use with pumps in hazardous locations.
XFL70-P4 R11/22/2015 ©Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
XFL70 - Series Technical Data
IMPELLER
SOLIDS HANDLING SIZE 3/4
PAINT POWDER COAT
MAX LIQUID TEMP 40˚C 104˚F
MAX STATOR TEMP 130˚C 266˚F
THERMAL OVERLOAD 105˚C 221˚F
POWER CORD TYPE SOOW
MOTOR HOUSING CLASS 30 CAST IRON
VOLUTE CLASS 30 CAST IRON
SHAFT STAINLESS
HARDWARE STAINLESS
O RINGS BUNA - N
MECHANICAL SEAL UPPER
MECHANICAL SEAL LOWER
MIN BEARING LIFE 50,000 HRS
WEIGHT 89 LBS
XFL70 - Series Specifications
1.01 GENERAL:
The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal pumps as specified
herein. The pump models covered in this specification are Series XFL70 single phase or three phase pumps. The pump furnished for this
application shall be model ______________as manufactured by Liberty pumps.
2.01 OPERATING CONDITIONS:
Each submersible pump shall be rated at _____ hp_____ volts _______ phase 60 Hz. 3450 RPM. The unit shall produce ______G.P.M. at
______ feet of total dynamic head.
The submersible pump shall be capable of handling residential effluent with 3/4” solid handling capability. The submersible pump shall have
the following hydraulic performance:
XFL70: a shut-off head of 48 feet and a maximum flow of 112 GPM @ 5 feet of total dynamic head.
The pump shall be controlled with:
______A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm.
______A NEMA 1 indoor simplex control panel with three float switches and a high water alarm.
______A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm.
______A NEMA 1 indoor duplex control panel with three float switches and a high water alarm.
______A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm.
______A NEMA 1 indoor duplex control panel with four float switches and a high water alarm.
*Note: Control panels must include intrinsically safe float circuits when pumps are installed in hazardous locations.
XFL70-P5 R11/22/2015 ©Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
3.01 CONSTRUCTION:
Each centrifugal effluent pump shall be equal to the certified XFL70 Series pumps manufactured by Liberty Pumps, Bergen NY. The
castings shall be constructed of class 30 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be
considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with Buna-N O-
rings. All fasteners exposed to the liquid shall be stainless steel. The upper and lower bearing of the motor shall be capable of handling all
radial and thrust loads. The pump is protected with a dual seal configuration with an oil cavity between the two seals. A leak sensor is housed
in this chamber to detect the presence of water and will activate an alarm at the control panel indicating service is required. Both seals are
silicon carbide / silicon carbide with stainless steel housings and spring, however the lower seal is of a two piece design to facilitate service.
4.01 ELECTRICAL POWER CORD
The submersible pump shall be supplied with 25 or 35 feet of a multi-conductor cord of type SOOW The power cord shall be sized for the rated
full load amps of the pump in accordance with the National Electric Code. A separate control cord SOOW of equal length will also exit the
pump. Both cords are located within a casting configured for 1-1/2” conduit if the application requires. The cords are secured with a rubber seal
ring and potted the individual strands are exposed to the epoxy to prevent any wicking through the conductors.
5.01 MOTORS
Single phase motors shall be oil filled, permanent split capacitor, class F insulated, NEMA B design, rated for continuous duty. Three phase
motors shall be oil filled, class F insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not
exceed 130 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. Single
phase pump motors shall have an integral thermal / current overload switch in the windings for protecting the motor. A capacitor is required
and shall be mounted in the control panel. Three phase motors shall have a thermal overload device mounted on the windings which is
connected to a motor control relay located in the control panel.
6.01 BEARINGS AND SHAFT
Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently
lubricated by the oil which fills the motor housing. The motor shaft shall be made of 300 series stainless steel and have a minimum diameter of
.625".
7.01 SEALS
The pump shall have two shaft seals with an oil chamber between them. A leak detection probe is positioned in the oil chamber and
continuously monitors for water that would indicate the lower seal has failed. The lower seal is a two piece design and can be serviced in the
field. The upper is a unitized design, both seals are silicon carbide / silicon carbide seal faces with stainless steel housings and springs. All
other seals are of an O-ring design of Buna N material.
8.01 IMPELLER
The impeller shall be a class 25 cast iron or bronze, with pump out vanes on the back shroud to keep debris away from the seal area. It shall
be threaded onto the motor shaft.
9.01 CONTROLS
All the XFL70 series pumps require a control panel. Single phase units utilize a Permanent Split Capacitor, PSC, type motor and require a
specific run capacitor. Three phase motor are equipped with a thermal overload that must be connected in the control panel to protect against
overheating. Control panels must include intrinsically safe float circuits when pumps are installed in hazardous locations.
XFL70-P6 R11/22/2015 ©Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
10.01 PAINT
The exterior of the casting shall be protected with Powder Coat paint.
11.01 SUPPORT
The pump shall have cast iron support legs, enabling it to be a free standing unit. The legs will be high enough to allow 3/4solids to enter the
volute.
12.01 SERVICEABILITY
Components required for the repair of the pump shall be shipped within a period of 24 hours.
13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE
______ Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile
grommets or o-rings. The Discharge piping shall be schedule 80 PVC and furnished with a check valve and PVC shut-off ball valve. The Tank
shall be wound fiberglass or roto-molded plastic. An inlet hub shall be provided with the fiberglass systems.
______ Stainless steel Guide Rail
______ Zinc plated steel Guide Rail
______ "diameter of basin size
______ "height of basin size
______ "distance from top of tank to discharge pipe outlet
______ Fiberglass cover
______ Structural foam polymer cover
______ Steel cover
______ Simplex System with Outdoor panel and alarm
______ Duplex System with Outdoor panel and alarm
______ Simplex System with Indoor panel and alarm
______ Duplex System with Indoor panel and alarm
______ Separate Outdoor Alarm
______ Remote Outdoor Alarm
14.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and
insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor
enclosure. The pump shall be run, voltage and current monitored, and evaluated for noise or other malfunction.
15.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified Facility.
16.01 WARRANTY
Standard limited warranty shall be 3 years.

Navigation menu