Ion® Digital Level Control
Digital Level Control Switch

OPERATION MANUAL

Dated: 10/05/2015
Document Name: IonDigitalLevelControl_OM
Page 1 of 4
of the switch. From this point, measure up either 6” or
8.5”, depending on your switch’s range, to find the On
level. Please refer to the Installation Drawing.
CAUTION: Bottom of switch should not be
mounted lower than suction inlet of pump.
When installing the Ion® switch with the pipe mounted
bracket be sure not to set the switch too low or too
high on the pipe. The Ion® must be installed above the
inlet of the pump to prevent air-locking as shown in
the installation drawing.

Patent pending

Features
1.	 First of its kind, solid-state sensing technology
with no moving parts.
2.	 Space age design
contact points.

with

no

mechanical

3.	 Multipoint sealing mechanism that supersedes
single surface seals.
4.	 Inverter rated for use with any battery
back-up system.
5.	 Standard piggy back connection for use with
any pump.
6.	 Suitable for sump and sewage applications.

Pipe Mounting Bracket (Optional)
1.	 Determine bracket mounting position (Figure
A).
2.	 Mount bracket to Ion® switch with screw already
provided in Ion® switch (Figure B).
3.	 Mount Hose Clamp with switch around pipe
at predetermined level. Cable should remain
outside hose clamp (Figure C).
4.	 Tighten hose clamp.
Note: The Ion® switch is available in 6” or 8.5” ranges.
A 10” range is available for special applications. See
chart for available ranges and cord lengths. The range
of the switch is the distance between the On and Off
levels. The Off level is at the bracket mounting screw

To prevent flooding do not set the on point of the
switch higher than the top of the basin.
Model

Cord

Range

IN-006-010-10PA-B

10

6

IN-085-010-10PA-B

10

8.5

IN-006-020-10PA-B

20

6

IN-085-020-10PA-B

20

8.5

Piggy-Back Installation
Electrical outlet must not be located in pump pit.
Electrical outlet voltage, piggy-back plug voltage and
pump voltage must all be the same voltage.
DO NOT CUT plug off unit.
Ensure vent tube on plug is protected from moisture,
dirt and insects and other items that could plug or
block tube.
1.	 Insert the Ion® switch’s piggy-back plug into
the outlet.
2.	 Plug pump into piggy-back plug as (Figure E).
3.	 Allow system to cycle to ensure proper
installation.
Please note this product may not work in
conjunction with other controllers.
Note: The Ion® switch does not operate like a standard
pressure switch. There are no contacts to wear out,
so when pressure is applied, there will not be a click.

www.ionproducts.net

Ion® Digital Level Control

OPERATION MANUAL

Dated: 10/05/2015
Document Name: IonDigitalLevelControl_OM
Page 2 of 4

Digital Level Control Switch

Safety Precautions

FIGURE B

FIGURE C

CAUTION: To prevent electric shock, ensure
product is connected to a grounded outlet.
The electrical outlet should be properly wired to a
dedicated 15A circuit breaker. Proper short-circuit
and overload protection must be provided at the
distribution panel. Install in accordance with all local
and national electrical codes.
WARNING: Electrical outlet must not be
located in pump pit. For best performance, do
not use electrical extension cords.

5”

Ø 3 7/8”
FIGURE D

Installation Drawing

Ion® Digital
Level Switch

Recommended
1/8” anti-airlocking
hole (if not already
provided by pump
manufacturer)

Range
of 6”-8.5”

NOTE: If you purchased a pump with the Ion switch
hard-mounted to the pump (Figure D) and the
installation requires the switch be mounted to the
pipe, the pipe-mount bracket is sold separately, PN:
IN-SPB1-1.

Range
of 6”-8.5”

FIGURE E
Lowest
pump
off level
BE SURE TO MOUNT THE ION
SWITCH AT PROPER LEVEL.
FIGURE A

Optional
bracket

or

Ion® Switch
piggy back
Pump plug

www.ionproducts.net

Ion® Digital Level Control
Digital Level Control Switch

Troubleshooting
Switch Does Not Turn On Pump
1.	 Test the pump without the Ion® switch
a.	 Plug the pump directly into the wall outlet,
without plugging it into the switch plug.
b.	 If pump still does not run, see the
troubleshooting section in the pump
manual.
c.	 If the pump does run, continue to the next
step.
2.	 Test the switch with the pump
a.	 Plug the pump into the Ion® switch and
plugging the Ion switch plug into the wall.
b.	 Push up on the sensing plate through the
center hole on the underside of the switch.
Note that, being an electronic switch, you
will not hear a clicking sound.
c.	 If the pump does not turn on, the switch will
have to be replaced.

OPERATION MANUAL

Dated: 10/05/2015
Document Name: IonDigitalLevelControl_OM
Page 3 of 4
will have to be replaced with a lower
range Ion® switch.
c.	 For a pump-mounted switch, see Page
2, Figure D to verify that the On level is
appropriate for your basin.
i. If the On level is too high, the switch will
have to be replaced with a lower range
Ion switch.
Switch Does Not Turn Off Pump
1.	 Unplug the pump from the Ion® plug and then
unplug the Ion plug from the wall outlet.
2.	 Plug the pump back into the Ion® plug and plug
the Ion plug back into the wall outlet.
a.	 If the pump does not turn on right away, and
the water level is not at the On level, let the
pump go through an On / Off cycle a few
times to insure that the switch is functioning
properly. The basin may need to be filled
with a garden hose or bucket.
b.	 If the pump turns on right away, and the
water level is not at the On level, the switch
will have to be replaced.

d.	 If the pump does turn on, continue to the
next step.
3.	 Verify the range of the switch
a.	 The part number can be found on the
switch cord tag.
i. IN-006… = 6” range
ii. IN-085... = 8.5” range
iii. IN-010… = 10” range (for special
applications)
b.	 For a pipe-mounted switch, see Page 2,
Installation Drawing to verify that the On
level is appropriate for your basin.
i. Lower the switch on the pipe so the
On level is at a point within the basin,
insuring that the Off level does not fall
below the minimum level shown in the
Installation Drawing.

Warranty

is

VOID

if...

1.	 Using an extension cord.
2.	 Power cord has been cut or the grounding
prong removed or using an adapter fitting.
3.	 The switch has been disassembled or tampered
with.
4.	 Any tags or labels have been removed.
5.	 Used in a heavy grease application
6.	 Used in applications exceeding the designed
temperature range of 32 - 104 degrees F.

ii. If the On level is still too high, the switch

www.ionproducts.net

Ion® Digital Level Control
Digital Level Control Switch

OPERATION MANUAL

Dated: 10/05/2015
Document Name: IonDigitalLevelControl_OM
Page 4 of 4

3 Year Residential Warranty
1.	
Coverage	 and	 Term.	 Metropolitan	 Industries,	 Inc.	 (“Metropolitan”)	 warrants	 to	 the	 original	
purchaser	(the	“Buyer”)	of	each	Ion|StormPro	product	(the	“product”),	that	any	part	thereof	which	proves	to	
be	defective	in	material	or	workmanship	within	three	(3)	years	from	date	of	manufacture,	will	be	replaced	at	
no	charge	with	a	new	or	remanufactured	part,	F.O.B.	factory.	Buyer	shall	be	responsible	for	all	freight	charges	
and	all	costs	of	field	labor	or	other	charges	incurred	in	the	removal	and/or	reinstallation	of	any	product,	part	
or	component	thereof.
2.	
Exclusions.	 THE WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS AND
EXCLUSIONS:
	
(a)	
The	 Warranty	 excludes	 products	 or	 workmanship	 which	 becomes	 defective	 as	 a	 result	
of:	(i)	earthquake,	fire,	storms,	the	elements	or	any	other	acts	of	God;	(ii)	normal	wear	and	tear	from	use;	
(iii)	 accident,	 misuse,	 abuse	 or	 neglect;	 (iv)	 modifications	 made	 by	 Buyer	 or	 any	 third	 party,	 other	 than	
Metropolitan;	and	(v)	Buyer’s	failure	to	properly	install,	maintain,	service	and/or	operate	the	product	under	
normal	conditions	and	according	to	manufacturer’s	instructions.
	
(b)	
Metropolitan	 shall	 not	 be	 responsible	 for,	 and	 the	 Warranty	 shall	 not	 cover,	 extended	
damage	 which	 occurs	 because	 of	 Buyer’s	 failure	 to	 notify	 Metropolitan	 promptly	 in	 writing	 of	 apparent	
defects.
	
(c)	
Any	part	or	component	designated	as	manufactured	by	anyone	other	than	Metropolitan	
shall	be	covered	only	by	the	express	warranty	of	the	manufacturer	thereof.
	
(d)	
The	Warranty	shall	lapse	upon	Buyer’s	failure	to	fully	comply	with	the	terms	and	conditions	
of	its	contract	with	Metropolitan,	including	Buyer’s	failure	to	pay	the	purchase	price	for	the	product	or	any	
portion	thereof.	Buyer’s	subsequent	compliance	with	the	terms	and	conditions	of	any	such	contract,	will	not	
cause	the	term	of	the	Warranty	to	extend	beyond	the	time	period	set	forth	above.
	
(e)	
No	actions	taken	by	Metropolitan	to	correct	a	defect	in	a	product	shall	extend	the	Warranty	
beyond	the	period	set	forth	above.	Metropolitan	shall	not	be	obligated	to	remedy	any	defect,	where	otherwise	
required	pursuant	to	the	Warranty	unless	and	until	Buyer	notifies	Metropolitan	in	writing	of	the	defect	and	
then	only	if	such	notification	is	made	prior	to	the	expiration	of	the	period	set	forth	above.
3.	
Process	of	Claims	and	Repairs.	Metropolitan	agrees	that	if	the	product	or	any	part	or	component	
thereof	shall	fail	to	conform	to	the	terms	of	this	Warranty,	Metropolitan	shall	replace	such	nonconforming	
product,	part	or	component	at	the	original	point	of	delivery	and	furnish	instruction	for	its	disposition.	Any	
transportation	charges	involved	in	such	disposition	and	all	costs	of	field	labor	or	other	charges	incurred	in	the	
removal	and/or	reinstallation	of	any	product,	part	or	component	thereof	shall	be	the	responsibility	of	Buyer.
4.	
Limitation	 on	 Liability.	 Notwithstanding	 any	 provision	 to	 the	 contrary,	 Metropolitan’s	 entire	
liability	 under	 this	 Warranty	 shall	 not	 in	 the	 aggregate	 exceed,	 and	 Buyer’s	 exclusive	 and	 sole	 remedies	
are,	 to	 the	 extent	 permitted	 by	 law,	 shall	 be	 to	 secure	 replacement	 of	 the	 defective	 product.	 UNDER NO
CIRCUMSTANCES SHALL METROPOLITAN BE LIABLE UNDER THE WARRANTY FOR
ANY INDIRECT, PUNITIVE, SPECIAL, EXEMPLARY, CONSEQUENTIAL OR INCIDENTAL
DAMAGES (INCLUDING LOST PROFITS, REVENUE, USE OR ECONOMIC ADVANTAGE).
5.	
Express	Waiver	of	Any	Other	Warranties.	THE EXPRESS WARRANTY SET FORTH IN THIS
WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY METROPOLITAN, OR ANY OTHER
PARTY, IN CONNECTION WITH ANY PRODUCT PURCHASED FROM METROPOLITAN.
NEITHER METROPOLITAN, NOR ANY OTHER PARTY, MAKES ANY OTHER EXPRESS OR
IMPLIED WARRANTY WHICH IS NOT SET FORTH HEREIN, AND METROPOLITAN HEREBY
DISCLAIMS AND BUYER HEREBY WAIVES ALL IMPLIED WARRANTIES, INCLUDING THE
IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS
FOR A PARTICULAR PURPOSE.
6.	
Not	Transferable.	The	Warranty	may	not	be	transferred	and	shall	be	void	on	the	sale	or	other	transfer	
of	the	product.
7.	
Products	and	Warranty	Subject	to	Change.	Metropolitan	reserves	the	right	to	make	revisions	to	its	
products	and	their	specifications,	and	to	revise	this	Warranty	and	related	information	without	notice.

www.ionproducts.net



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2015:10:06 10:04:33-05:00
Creator                         : Adobe InDesign CC 2015 (Macintosh)
Modify Date                     : 2017:05:05 11:17:16-04:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Metadata Date                   : 2017:05:05 11:17:16-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Instance ID                     : uuid:a83389e1-417d-4169-83d2-be1f2e2a697a
Original Document ID            : xmp.did:65D38F2A31A3E011ABCE80FFAE7578B0
Document ID                     : xmp.id:2a4eb5be-dee3-4d4e-81f1-56699bc5dfeb
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:aa65260c-b7f1-4215-9896-adc460d3103f
Derived From Document ID        : xmp.did:E7B93AB310206811822ADC13114848F6
Derived From Original Document ID: xmp.did:65D38F2A31A3E011ABCE80FFAE7578B0
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2015:10:06 10:04:33-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 4