549616 4 Grundfos Scala2 Service Instructions
: Pump 549616 4 Grundfos Scala2 Service Instructions 549616_4_Grundfos Scala2 Service Instructions pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
GRUNDFOS INSTRUCTIONS SCALA Service instructions Original service instructions 2. Identification CONTENTS 2.1 Nameplate Page 1. Symbols used in this document 2 2. Identification 2.1 Nameplate 2.2 Type key 2 2 3 3. Service tools 3.1 Standard tools 4 4 4. Lubricants 4 5. 5.1 5.2 5.3 5.4 5.5 Dismantling and assembly General information Removing the control box cover Removing the pressure tank Removing the chamber stack Removing the shaft seal 5 5 5 5 7 7 6. 6.1 6.2 6.3 Fitting the shaft seal Fitting the chamber stack Fitting the pressure tank Fitting the control box cover 7 8 8 9 7. 7.1 7.2 7.3 Fault finding the product Grundfos Eye operating indications Fault resetting Fault finding chart 10 10 10 11 8. Exploded view 13 14 15 Made in Serbia P/N 99999999 S/N P/C 1519 Hmax Hmin Hnom Qnom Tamb.max 16 04-6292.2.41-2003 LSPr-022-IDN I(A) P1(W) Min. 0.01 2 Max. 2.8 550 17 Fig. 1 Pos. Example of nameplate Description Product number Serial number 4 Production code, year and week 5 Maximum head 6 Minimum head 7 Rated head WARNING 8 Rated flow rate Indicates a hazardous situation which, if not avoided, could result in death or serious personal injury. 9 Maximum ambient temperature 10 IP class 11 Maximum operation pressure CAUTION 12 Maximum liquid temperature Indicates a hazardous situation which, if not avoided, could result in minor or moderate personal injury. 13 Minimum and maximum rated power The text accompanying the three hazard symbols DANGER, WARNING and CAUTION is structured in the following way: SIGNAL WORD Description of hazard Consequence of ignoring the warning. - Action to avoid the hazard. 5 6 7 8 9 10 11 12 3 If these instructions are not observed, it may result in malfunction or damage to the equipment. 4 45 m 16 m 27 m 3 3 m /h 55 C Tliq.max/Psyst.max: 45 C/1MPa NRP XXX-XXX-XXXXXX Type designation Indicates a hazardous situation which, if not avoided, will result in death or serious personal injury. 3 IPX4D PCS XXXXX.XX.XX 2 DANGER 2 SCALA2 3-45 AKCHDE Model A 200-240V 50/60Hz 1 1. Symbols used in this document 2 1 DK-8850 Bjerringbro, Denmark 14 Model 15 Voltage and frequency 16 Approvals 17 Minimum and maximum rated current 13 TM06 4340 2015 English (GB) English (GB) Service instructions SCALA2 3 -45 A K C H D English (GB) 2.2 Type key E Type range SCALA1 Economy SCALA2 Comfort Rated flow rate [m3/h] Maximum head [m] Material code A: Standard Supply voltage K: 1 x 200-240 V, 50/60 Hz M: 1 x 208-230 V, 60 Hz V: 1 x 115 V, 60 Hz W: 1 x 100-115 V, 50/60 Hz Motor C: High-efficiency motor with frequency converter Power supply cable and plug A: Cable with plug, IEC type I, AS/NZS3112, 2 m B: Cable with plug, IEC type B, NEMA 5-15P, 6 ft C: Cable with plug, IEC, type E&F, CEE7/7, 2 m D: Cable without plug, 2 m G: Cable with plug, IEC type G, BS1363, 2 m H: Cable with plug, IEC type I, IRAM 2073, 2 m J: Cable with plug, NEMA 6-15P, 6 ft Controller D: Integrated frequency converter Thread A: R 1" EN 1.4308 C: NPT 1" EN 1.4308 E: R 1" composite material F: NPT 1" composite material 3 English (GB) 3. Service tools 3.1 Standard tools A B E F C D Standard tools Pos. Range A All Torx screwdriver B All Torque screwdriver C All Bits kit D All Needle-nose pliers E All F Designation Description Part number - - 1-6 Nm SV0438 5 mm hexagon SV2010 - - Ring/open-end spanner M89 - 13 mm SV0055 Flat-blade screwdriver - - 4. Lubricants If nothing else is specified, all O-rings are to be lubricated with Rocol Sapphire Aqua-Sil. Product Product number Rocol Sapphire Aqua-Sil, 1 kg RM2924 Castrol Optimol Paste White T, 0.5 kg V6001176 4 5.3 Removing the pressure tank 5.1 General information 1. Slowly unscrew the non-return valve (65a) to release any pressure in the pump. DANGER 2. Remove the drain plug (7). Electric shock 3. Remove the union nut (100) by turning it counterclockwise by hand. Death or serious personal injury - Before starting any work on the product, make sure that the power supply has been switched off and that it cannot be accidentally switched on. 5. Pull out the non- return valve (65) from the inlet. 6. Remove the O-rings from the nipples, valves and plugs. 7. Carefully remove the pump cover (403) using a flat-blade screwdriver. 5.1.1 Before dismantling • 4. Pull out the nipples (100a). Disconnect the power supply to the motor. • Remove the power cable in accordance with local regulations. • Open a tap to release the pressure in the pipe system. • Gradually loosen the non-return valve (65a) to release the pressure in the pump. • Remove the drain plug (7) to drain the pump. To avoid damage to the connection part, insert the flat-blade screwdriver in the top slots and pop the cover loose by moving the screwdriver handle towards the pump body. See fig. 4. 5.1.2 Before assembly • Always replace gaskets and O-rings when you overhaul the pump. • Clean and check all parts. • Replace defective parts. 5.2 Removing the control box cover Always use an antistatic service kit when handling electronic components. This will prevent static electricity from damaging components. 1. Remove the six pan-head torx screws in the cover (164a). Removing the control box cover TM06 5282 4315 Fig. 2 Fig. 3 TM06 7639 3816 - TM0 67640 3816 - TM06 7641 3816 TM06 5151 3915 2. Carefully lift off the control box cover and disconnect the HMI plug. Fig. 4 Removing the cover Disconnecting the HMI plug 5 English (GB) 5. Dismantling and assembly English (GB) 10. Remove the screws (26) that hold the connection part. Note that one of the screws holds the earth connection bracket (173c) and washer. 11. Remove the connection part and the pressure tank. TM06 5150 3915 12. Remove the seal ring (44a). Fig. 5 Removing the nipples and the cover 8. Remove the retaining clip (175) for the sensor and remove the sensor (174a). TM06 5152 3915 TM06 5149 3915 9. Remove the sensor (174a). Removing the connection part 13. Remove the self-priming valve (10) and O-ring (37). Sensor and retaining clip TM06 5153 3915 Fig. 6 Fig. 7 Fig. 8 6 Self-priming valve and O-ring for connections part 5.5 Removing the shaft seal 1. Remove the rotating shaft seal face (104). TM06 5154 3915 2. Remove the stationary seat (103) using a needle-noise pliers. Removing the pressure tank TM06 5169 3915 Fig. 9 5.4 Removing the chamber stack 1. Remove the plug (169) on nameplate to access the shaft end. 2. Remove the locking nut (67) and the washer (66). Hold the shaft with a screwdriver in the shaft end. Fig. 12 Removing the stationary shaft seal 6. Fitting the shaft seal 107 112 102 108 111a Fig. 10 Loosening the locking nut for the chamber stack 111 3. Remove the chamber stack. 104 103 TM06 5341 4415 TM06 5155 3915 1. Fit the stationary seat (103) with the O-ring (102) against the pump housing. Fig. 13 Shaft seal complete Do not touch the ceramic faces of the shaft seal. TM06 5170 3915 2. Fit the rotating shaft seal face (104). TM06 5170 3915 Fig. 11 Chamber stack and shaft seal Fig. 14 Fitting the shaft seal and the chamber stack 7 English (GB) 14. Unscrew the pressure tank (42) counterclockwise and remove the gasket for the tank (42a). 3. Check that the self-priming valve is fitted correctly. 6.1 Fitting the chamber stack TM06 5158 3915 2. Fit the washer (66) and the locking nut (67) and tighten it to 5 Nm. Hold the shaft end using a screwdriver. Fig. 18 Correct position of the self-priming valve 4. Fit the connection part to the pump housing. Note that one screw holds the earth connection bracket and the washer. 5. Cross-tighten the screws according to table below. Fig. 15 Tightening the nut of the chamber stack 6.2 Fitting the pressure tank TM06 5154 3915 1. Fit the flat gasket (42a) and screw the pressure tank (42) on to the connection part (2) by hand. Fig. 16 Fitting the pressure tank TM06 5149 3915 2. Fit the self-priming valve (10) and the O-ring (37). Fig. 19 Fitting the connection part Sequence Torque [Nm] 1 2 3 4 TM06 5153 3915 English (GB) 1. Fit the impellers (49), the seal (45) and the chambers (4). Fit the seal ring (44a) last. Fig. 17 Fitting the self-priming valve and the O-ring 8 5 6 3 ± 0.5 6. Fit the sensor (174a) and fasten it by means of the retaining clip (175). 1. Connect the HMI plug and place the control box cover on the pump. TM06 5152 3915 TM06 5150 3915 Check that the rubber sensor pocket is are seated correctly. Fig. 22 Connecting the HMI plug Fig. 20 Sensor and retaining clip 2. Cross-tighten the six pan-head torx screws according to the table below. 7. Press the pump cover back onto the pump housing. 8. Fit new O-rings to the valves, nipples and plugs. 9. Fit the inlet valve in the connection part. 10. Press the nipples into the connection part, fit the union nuts and tighten them by hand. 11. Fit the drain plug (7) and the non-return valve (65a). 3-6 3-6 1-4 1-4 2-5 2-5 TM06 4959 0516 Always tighten plastic nuts and plugs by hand so as not to break the material. Fig. 23 Tightening sequence TM06 5150 3915 Sequence Fig. 21 Fitting the nipples and the cover Torque [Nm] 1 2 3 4 2 ± 0.25 5 6 9 English (GB) 6.3 Fitting the control box cover English (GB) 7. Fault finding the product 7.1 Grundfos Eye operating indications Grundfos Eye Indication Description No lights are on. The power is off. The pump is not running. Two opposite green indicator lights running in the The power is on. direction of rotation of the pump. The pump is running. Two opposite green indicator lights at a 45 ° The power is on. angle is the icon used throughout this document The pump is running. for pump running. Two opposite green indicator lights permanently The power is on. on. The pump is not running. Two opposite red indicator lights flashing simultaneously. Alarm. The pump has stopped. Two opposite red indicator lights is the icon used Alarm. throughout this document for pump stopped. The pump has stopped. 7.2 Fault resetting You can reset a fault indication in one of the following ways: • When you have eliminated the fault cause, reset the pump manually by pressing the button. The pump then reverts to normal duty. • If the fault disappears by itself, the pump attempts to reset automatically and the fault indication disappears if automatic reset is successful and provided that you have enabled "Auto reset" in the service menu. 10 English (GB) 7.3 Fault finding chart DANGER Electric shock Automatic reset Indicator light Fault Grundfos Eye Death or serious personal injury - Before starting any work on the product, make sure that the power supply has been switched off and that it cannot be accidentally switched on. Cause Remedy Power supply failure. Switch on the power supply. Check the cables and cable connections for defects and loose connections and check for blown fuses in the electrical installation. Yes The power supply is out of the prescribed voltage range. Check the power supply and the pump nameplate. Reestablish the power supply within the prescribed voltage range. No The shaft seal has seized up. Remove the end cover plug and deblock the shaft seal by turning the shaft by means of a screwdriver. No The pump is blocked by impurities. Contact Grundfos Service if the problem persists. Yes Dry running. Check the water source, and prime the pump. No The maximum runtime has been exceeded. Check the installation for leakage and reset the alarm. No The internal non-return valve is defective or blocked in completely or partly open position. Clean, repair or replace the non-return valve. - Leakage from the pipes, or the non-return valve is not properly closed due to impurities. Check and repair the pipes, or clean, repair or replace the non-return valve. - Small continuous consumption. Check the taps and reconsider the usage pattern (ice machines, water evaporators for air-conditioning, etc.). - The temperature is below the freezing point. Consider protecting the pump and the installation against frost. - The pump inlet pressure is too low. Check the inlet conditions of the pump. The pump is undersized. Replace the pump with a bigger pump. 1. The pump is not running. - 2. The pump is running. 3. Pump performance is insufficient. - - - - - The inlet pipe, the inlet strainer or the pump is partly blocked by impurities. Clean the inlet pipe or the pump. - - Leakage in the inlet pipe. Repair the inlet pipe. - - Air in the inlet pipe or the pump. Prime the inlet pipe and the pump. Check the inlet conditions of the pump. - - The required outlet pressure is too low for the installation. Increase the pressure setting (arrow up). The maximum temperature has been exceeded and the pump is running at reduced performance. Check the cooling conditions. Protect the pump against direct sunlight or any nearby heat sources. Yes 11 Automatic reset Indicator light Grundfos Eye English (GB) Fault Cause Remedy Yes The setpoint has been set too high. The difference between the outlet pressure and the inlet pressure must not exceed 4 bar (58 psi). Example: If the required outlet pressure is 5 bar (73 psi), the minimum inlet pressure must be 1 bar (14.5 psi). Reduce the setpoint to 4 bar (58 psi) plus positive inlet pressure. Yes The maximum pressure has been exceeded and the inlet pressure is higher than 6 bar, 0.6 MPa (85 psi) Check the inlet conditions. Yes The maximum pressure has been exceeded. Equipment elsewhere in the system causes a high pressure at the pump (e.g. water heater or defective safety equipment). Check the installation. Yes Dry running or water shortage. Check the water source, and prime the pump. Yes The inlet pipe is blocked by impurities. Clean the inlet pipe. Yes The foot or non-return valve is blocked in closed position. Clean, repair or replace the foot or non-return valve. Yes Leakage in the inlet pipe. Repair the inlet pipe. Yes Air in the inlet pipe or the pump. Prime the inlet pipe and the pump. Check the inlet conditions of the pump. No The internal non-return valve is defective or blocked in completely or partly open position. Clean, repair or replace the non-return valve. No The tank precharge pressure is not correct. Adjust the tank precharge pressure to 70 % of the required outlet pressure. 4. System overpressure. 5. You can reset the pump, but the pump runs only for a few seconds. 6. You can reset the pump, but the pump starts repeatedly, immediately after stopping. 12 TM06 4966 3615 English (GB) 8. Exploded view Fig. 24 Exploded view 13 Position number list English (GB) Pos. Description 2 Connection part 4 Chamber 7 Drain plug 10 Self-priming valve 11a O-ring 26 Screw 26c Lock washer 37 O-ring 42 Tank complete 42a Flat gasket 44 Inlet part 44a Seal ring 45 Seal 49 Impeller 65 Non-return valve, inlet 65a Non-return valve, outlet 66 Washer 67 Locking nut 100 Union nut 100a Nipple 100b O-ring 102 O-ring 103 Stationary seat 104 Rotating seal face 105 Shaft seal complete 107 O-ring 108 Spring 111 Seal driver 111a Washer 112 Seal driver 164 Control box cover 164a Pan-head torx screw 169 Plug 173 Double-end stud bolt 173a Lock washer 173b Hexagon nut 173c Earth connection bracket 173d O-ring 174a Sensor complete 175 Retaining clip 180 Combined pump and stator housing 403 Pump cover Subject to alterations. 14 Finland Malaysia Spain Bombas GRUNDFOS de Argentina S.A. Ruta Panamericana km. 37.500 Centro Industrial Garin 1619 Garín Pcia. de B.A. Phone: +54-3327 414 444 Telefax: +54-3327 45 3190 OY GRUNDFOS Pumput AB Trukkikuja 1 FI-01360 Vantaa Phone: +358-(0) 207 889 500 GRUNDFOS Pumps Sdn. Bhd. 7 Jalan Peguam U1/25 Glenmarie Industrial Park 40150 Shah Alam Selangor Phone: +60-3-5569 2922 Telefax: +60-3-5569 2866 Bombas GRUNDFOS España S.A. Camino de la Fuentecilla, s/n E-28110 Algete (Madrid) Tel.: +34-91-848 8800 Telefax: +34-91-628 0465 Australia GRUNDFOS Pumps Pty. Ltd. P.O. Box 2040 Regency Park South Australia 5942 Phone: +61-8-8461-4611 Telefax: +61-8-8340 0155 Austria GRUNDFOS Pumpen Vertrieb Ges.m.b.H. Grundfosstraße 2 A-5082 Grödig/Salzburg Tel.: +43-6246-883-0 Telefax: +43-6246-883-30 Belgium N.V. GRUNDFOS Bellux S.A. Boomsesteenweg 81-83 B-2630 Aartselaar Tél.: +32-3-870 7300 Télécopie: +32-3-870 7301 Belarus Представительство ГРУНДФОС в Минске 220125, Минск ул. Шафарнянская, 11, оф. 56, БЦ «Порт» Тел.: +7 (375 17) 286 39 72/73 Факс: +7 (375 17) 286 39 71 E-mail: minsk@grundfos.com Bosnia and Herzegovina GRUNDFOS Sarajevo Zmaja od Bosne 7-7A, BH-71000 Sarajevo Phone: +387 33 592 480 Telefax: +387 33 590 465 www.ba.grundfos.com e-mail: grundfos@bih.net.ba France Pompes GRUNDFOS Distribution S.A. Parc d’Activités de Chesnes 57, rue de Malacombe F-38290 St. Quentin Fallavier (Lyon) Tél.: +33-4 74 82 15 15 Télécopie: +33-4 74 94 10 51 Germany GRUNDFOS GMBH Schlüterstr. 33 40699 Erkrath Tel.: +49-(0) 211 929 69-0 Telefax: +49-(0) 211 929 69-3799 e-mail: infoservice@grundfos.de Service in Deutschland: e-mail: kundendienst@grundfos.de Greece GRUNDFOS Hellas A.E.B.E. 20th km. Athinon-Markopoulou Av. P.O. Box 71 GR-19002 Peania Phone: +0030-210-66 83 400 Telefax: +0030-210-66 46 273 Hong Kong GRUNDFOS Pumps (Hong Kong) Ltd. Unit 1, Ground floor Siu Wai Industrial Centre 29-33 Wing Hong Street & 68 King Lam Street, Cheung Sha Wan Kowloon Phone: +852-27861706 / 27861741 Telefax: +852-27858664 Hungary GRUNDFOS Hungária Kft. Park u. 8 H-2045 Törökbálint, Phone: +36-23 511 110 Telefax: +36-23 511 111 Brazil India BOMBAS GRUNDFOS DO BRASIL Av. Humberto de Alencar Castelo Branco, 630 CEP 09850 - 300 São Bernardo do Campo - SP Phone: +55-11 4393 5533 Telefax: +55-11 4343 5015 GRUNDFOS Pumps India Private Limited 118 Old Mahabalipuram Road Thoraipakkam Chennai 600 096 Phone: +91-44 2496 6800 Bulgaria Grundfos Bulgaria EOOD Slatina District Iztochna Tangenta street no. 100 BG - 1592 Sofia Tel. +359 2 49 22 200 Fax. +359 2 49 22 201 email: bulgaria@grundfos.bg Canada GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: +1-905 829 9533 Telefax: +1-905 829 9512 China GRUNDFOS Pumps (Shanghai) Co. Ltd. 10F The Hub, No. 33 Suhong Road Minhang District Shanghai 201106 PRC Phone: +86 21 612 252 22 Telefax: +86 21 612 253 33 Croatia GRUNDFOS CROATIA d.o.o. Buzinski prilaz 38, Buzin HR-10010 Zagreb Phone: +385 1 6595 400 Telefax: +385 1 6595 499 www.hr.grundfos.com GRUNDFOS Sales Czechia and Slovakia s.r.o. Čajkovského 21 779 00 Olomouc Phone: +420-585-716 111 Denmark GRUNDFOS DK A/S Martin Bachs Vej 3 DK-8850 Bjerringbro Tlf.: +45-87 50 50 50 Telefax: +45-87 50 51 51 E-mail: info_GDK@grundfos.com www.grundfos.com/DK Estonia GRUNDFOS Pumps Eesti OÜ Peterburi tee 92G 11415 Tallinn Tel: + 372 606 1690 Fax: + 372 606 1691 Indonesia PT. GRUNDFOS POMPA Graha Intirub Lt. 2 & 3 Jln. Cililitan Besar No.454. Makasar, Jakarta Timur ID-Jakarta 13650 Phone: +62 21-469-51900 Telefax: +62 21-460 6910 / 460 6901 Ireland GRUNDFOS (Ireland) Ltd. Unit A, Merrywell Business Park Ballymount Road Lower Dublin 12 Phone: +353-1-4089 800 Telefax: +353-1-4089 830 Italy GRUNDFOS Pompe Italia S.r.l. Via Gran Sasso 4 I-20060 Truccazzano (Milano) Tel.: +39-02-95838112 Telefax: +39-02-95309290 / 95838461 Japan GRUNDFOS Pumps K.K. 1-2-3, Shin-Miyakoda, Kita-ku, Hamamatsu 431-2103 Japan Phone: +81 53 428 4760 Telefax: +81 53 428 5005 Korea GRUNDFOS Pumps Korea Ltd. 6th Floor, Aju Building 679-5 Yeoksam-dong, Kangnam-ku, 135-916 Seoul, Korea Phone: +82-2-5317 600 Telefax: +82-2-5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60, LV-1035, Rīga, Tālr.: + 371 714 9640, 7 149 641 Fakss: + 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g. 6 LT-03201 Vilnius Tel: + 370 52 395 430 Fax: + 370 52 395 431 Mexico Bombas GRUNDFOS de México S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010 Netherlands GRUNDFOS Netherlands Veluwezoom 35 1326 AE Almere Postbus 22015 1302 CA ALMERE Tel.: +31-88-478 6336 Telefax: +31-88-478 6332 E-mail: info_gnl@grundfos.com New Zealand Sweden GRUNDFOS AB Box 333 (Lunnagårdsgatan 6) 431 24 Mölndal Tel.: +46 31 332 23 000 Telefax: +46 31 331 94 60 Switzerland GRUNDFOS Pumpen AG Bruggacherstrasse 10 CH-8117 Fällanden/ZH Tel.: +41-44-806 8111 Telefax: +41-44-806 8115 Taiwan GRUNDFOS Pumps (Taiwan) Ltd. 7 Floor, 219 Min-Chuan Road Taichung, Taiwan, R.O.C. Phone: +886-4-2305 0868 Telefax: +886-4-2305 0878 Thailand GRUNDFOS Pumps NZ Ltd. 17 Beatrice Tinsley Crescent North Harbour Industrial Estate Albany, Auckland Phone: +64-9-415 3240 Telefax: +64-9-415 3250 GRUNDFOS (Thailand) Ltd. 92 Chaloem Phrakiat Rama 9 Road, Dokmai, Pravej, Bangkok 10250 Phone: +66-2-725 8999 Telefax: +66-2-725 8998 Norway GRUNDFOS POMPA San. ve Tic. Ltd. Sti. Gebze Organize Sanayi Bölgesi Ihsan dede Caddesi, 2. yol 200. Sokak No. 204 41490 Gebze/ Kocaeli Phone: +90 - 262-679 7979 Telefax: +90 - 262-679 7905 E-mail: satis@grundfos.com GRUNDFOS Pumper A/S Strømsveien 344 Postboks 235, Leirdal N-1011 Oslo Tlf.: +47-22 90 47 00 Telefax: +47-22 32 21 50 Poland GRUNDFOS Pompy Sp. z o.o. ul. Klonowa 23 Baranowo k. Poznania PL-62-081 Przeźmierowo Tel: (+48-61) 650 13 00 Fax: (+48-61) 650 13 50 Portugal Bombas GRUNDFOS Portugal, S.A. Rua Calvet de Magalhães, 241 Apartado 1079 P-2770-153 Paço de Arcos Tel.: +351-21-440 76 00 Telefax: +351-21-440 76 90 Romania Turkey Ukraine Бізнес Центр Європа Столичне шосе, 103 м. Київ, 03131, Україна Телефон: (+38 044) 237 04 00 Факс.: (+38 044) 237 04 01 E-mail: ukraine@grundfos.com United Arab Emirates GRUNDFOS Gulf Distribution P.O. Box 16768 Jebel Ali Free Zone Dubai Phone: +971 4 8815 166 Telefax: +971 4 8815 136 GRUNDFOS Pompe România SRL Bd. Biruintei, nr 103 Pantelimon county Ilfov Phone: +40 21 200 4100 Telefax: +40 21 200 4101 E-mail: romania@grundfos.ro United Kingdom Russia U.S.A. GRUNDFOS Pumps Ltd. Grovebury Road Leighton Buzzard/Beds. LU7 4TL Phone: +44-1525-850000 Telefax: +44-1525-850011 ООО Грундфос Россия 109544, г. Москва, ул. Школьная, 39-41, стр. 1 Тел. (+7) 495 564-88-00 (495) 737-30-00 Факс (+7) 495 564 88 11 E-mail grundfos.moscow@grundfos.com GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 Serbia Grundfos Srbija d.o.o. Omladinskih brigada 90b 11070 Novi Beograd Phone: +381 11 2258 740 Telefax: +381 11 2281 769 www.rs.grundfos.com Grundfos Tashkent, Uzbekistan The Representative Office of Grundfos Kazakhstan in Uzbekistan 38a, Oybek street, Tashkent Телефон: (+998) 71 150 3290 / 71 150 3291 Факс: (+998) 71 150 3292 Singapore Addresses Revised 02.09.2016 GRUNDFOS (Singapore) Pte. Ltd. 25 Jalan Tukang Singapore 619264 Phone: +65-6681 9688 Telefax: +65-6681 9689 Slovakia GRUNDFOS s.r.o. Prievozská 4D 821 09 BRATISLAVA Phona: +421 2 5020 1426 sk.grundfos.com Slovenia GRUNDFOS LJUBLJANA, d.o.o. Leskoškova 9e, 1122 Ljubljana Phone: +386 (0) 1 568 06 10 Telefax: +386 (0)1 568 06 19 E-mail: tehnika-si@grundfos.com South Africa GRUNDFOS (PTY) LTD Corner Mountjoy and George Allen Roads Wilbart Ext. 2 Bedfordview 2008 Phone: (+27) 11 579 4800 Fax: (+27) 11 455 6066 E-mail: lsmart@grundfos.com Uzbekistan Grundfos companies Argentina ECM: 1197159 www.grundfos.com The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. 98979478 1116 © Copyright Grundfos Holding A/S
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2016:11:14 09:16:06Z Creator : FrameMaker 10.0.2 Modify Date : 2017:05:08 09:19:24-04:00 Language : en XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Producer : Acrobat Distiller 10.1.13 (Windows) Creator Tool : FrameMaker 10.0.2 Metadata Date : 2017:05:08 09:19:24-04:00 Format : application/pdf Title : untitled Document ID : uuid:ba6a0cfe-9b3a-43d7-a822-c50c3a773524 Instance ID : uuid:24a1c2fb-c263-4c5c-8a09-1981186ea8e7 Page Mode : UseOutlines Page Count : 16EXIF Metadata provided by EXIF.tools