551519 1 Amtrol FT 109 Fill Trol Expansion Tank Brochure

551502 1 Amtrol Radiant Extrol Rx-30 Expansion Tank Brochure 551502_1_Amtrol Radiant Extrol RX-30 Expansion Tank Brochure 551502_1_Amtrol Radiant Extrol RX-30 Expansion Tank Brochure pdf pumpproducts

: Pump 551519 1 Amtrol Ft-109 Fill-Trol Expansion Tank Brochure 551519_1_Amtrol FT-109 Fill-Trol Expansion Tank Brochure pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

Boiler System Expansion Tanks
Extrol®. Celebrating 60 Years.
2
1946
American Tube Products
founded in West Warwick,
Rhode Island
Invented the
diaphragm
expansion tank
Invented the
refrigerant
gas cylinder
Entered the
commercial
products business
Invented the
top coil indirect
Hot Water Maker®
Invented the
thermal
expansion tank
1954 1967 1975 1986 1991
Invented the
pre-pressurized
well tank
Built current
Rhode Island
manufacturing
facility
Invented the
indirect-red
Hot Water Maker®
Opened the
Amtrol Education
Center
AMTROL
registered ISO 9001
1963 1972 1980 1988 1992
Amtrol Inc. designed and patented the first Extrol® diaphragm expansion tank
in 1954 to control system pressure and help reduce energy consumption
in heating and chilled water systems. Over six decades later, Extrol is
still the world’s leading expansion tank brand, setting the standard
for quality, reliability and innovation.
All Extrol tanks are made in the USA at our ISO registered
facilities by American workers dedicated to producing the
highest quality expansion tanks in the world.
Amtrol’s patent for the
rst diaphragm tank was
issued 60 years ago.
3
The complete line of Extrol tanks includes inline, oor-standing, air
elimination packages and special application models.
AMTROL registered
ISO 9001:2000
Launched
Next Generation
Well-X-Trol®
20 millionth
well tank shipped
Launched
HydroMax®
Hot Water Makers
Extrol®
60th Anniversary
2003 2009 2012 2014
Acquired
ALFA Cylinder
Manufacturing
in Portugal
Invented the
composite metal
LP tank
Launched
Amtrol Rewards
Well-X-Trol®
50th Anniversary
1997 2005 20132010
®
AMTROL registered
ISO 9001:2008
Tanks on Tour
mobile education center
hits the road
The One That Started It All.
4
Factory precharge: 12 psig
Max. working pressure: 100 psig
Max. operating temperature: 240°F
Automatic Air Vent
eliminates system air
Air Purger
separates air from water
System connection sets the
point of no pressure change
Watertight reservoir
for expanded water
Thick, heavy duty Butyl/EPDM
diaphragm for long service life
Strong, deep-drawn steel tank
Sealed air cushion — factory
pre-charged and 100% tested
Projection-welded air stem
maintains precharge setting
5
System
Supply
Circulator
Air
Purger
Air Vent
Extrol
Expansion
Tank
Boiler
System
Return
Cold
Water
Supply
Fill
Valve
Typical Installation
Boiler Type of Radiation
Net Output
in 1000’S
of BTU/Hr.
Finned Baseboard
or Radiant Panels
Convectors
or Unit Heaters
Radiators
Cast Iron
Baseboard
Cast Iron
MBH Use Model Use Model Use Model Use Model
25 EX-15 EX-15 EX-15 EX-15
50 EX-15 EX-15 EX-30 EX-30
75 EX-30 EX-30 EX-30 EX-60
100 EX-30 EX-30 EX-60 EX-60
125 EX-30 EX-60 EX-60 EX-90
150 EX-30 EX-60 EX-90 EX-90
175 EX-60 EX-60 SX Series SX Series
200 EX-60 EX-60 SX Series SX Series
250 EX-60 EX-90 SX Series SX Series
300 EX-90 SX Series SX Series SX Series
Sizing based on: 12 psig Fill; 30 psig Relief Valve; 200°F Average Temperature.
For sizing with fluids other than water, visit amtrol.com, download the AMTROL App or consult AMTROL Technical Support.
Models and Specications
EX Series Specifications
EX Series Combination Packages
EX Series Sizing
Model
Number
Tank
Volume
(Gallons)
Max.
Acceptance
Factor (Gallons)
A
Diameter
(Inches)
B
Height
(Inches)
System
Connection
(NPTM)
Shipping
Weight
(lbs.)
EX-15 2.0 1.0 813 125
EX-30 4.4 2.5 11 15 129
EX-60 7.4 2.5 11 23 1214
EX-90 14.0 11.3 15 21 1223
Model
Number
System
Connections
(NPTF)
EXTROL
Model
Air Purger
Model
Air Vent
Model
Shipping
Weight
(lbs.)
EX-1500-100 1 EX-15 443 700-C 10
EX-1500-125 1 14EX-15 444 700-C 10
EX-3000-100 1 EX-30 443 700-C 14
EX-3000-125 1 14EX-30 444 700-C 14
6
Floor-Standing Models
Model
Number
Tank
Volume
(Gallons)
Max.
Accept.
Volume
(Gallons)
A
Diameter
(Inches)
B
Height
(Inches)
System
Connection
(NPTF)
Shipping
Weight
(lbs.)
SX-30V 14 11.3 15 24 1 25
SX-40V 20 11.3 15 32 1 33
SX-60V 32 11.3 15 48 1 43
SX-90V 44 34.0 22 36 11469
SX-110V 62 34.0 22 47 11492
SX-130V 81 34.0 22 56 114103
SX-160V 86 46.0 26 47 114123
Factory pre-charge: 12 psig.
Maximum working pressure: 100 psig.
Maximum operating temperature: 240°F.
Boiler Type of Radiation and Piping System
Net Output in
1000’s of BTU
Finned Tube
Baseboard or Radiant
Panels with Series
Loop System
Convectors or
Unit Heaters
with One Pipe
System
Radiators
or
One Pipe
System
Cast Iron
Radiators
with Series
Loop System
200 SX- 30V SX-30V SX-30V SX-30V
250 SX- 30V SX-30V SX-30V SX-40V
300 SX- 30V SX-30V SX-40V SX-40V
350 SX-30V SX-30V SX-40V SX-60V
400 SX-30V SX-40V SX-60V SX-60V
450 SX-40V SX-40V SX-90V SX-90V
500 SX-40V SX-40V SX-60V SX-90V
550 SX-40V SX-60V SX-60V SX-90V
600 SX-40V SX-60V SX-90V SX-90V
650 SX-60V SX-60V SX-90V SX-90V
700 SX-60V SX-60V SX-90V SX-90V
750 SX-60V SX-60V SX-90V SX-110V
800 SX-60V SX-90V SX-90V SX-110V
850 SX-60V SX-90V SX-90V SX-110V
900 SX-60V SX-90V SX-110V SX-110V
950 SX-90V SX-90V SX-110V SX-110V
1,000 SX-90V SX-90V SX-110V SX-110V
1,100 SX-90V SX-90V SX-110V SX-130V
1,200 SX-90V SX-90V SX-110V SX-130V
1,300 SX-90V SX-110V SX-130V SX-160V
1,400 SX-110V SX-130V SX-160V SX-160V
1,500 SX-110V SX-130V SX-160V (2)SX-110V
Sizing
Sizing based on: Average Boiler Water Volume; Average Water Volume;
Fill Pressure 12 psig; Relief Pressure 30 psig
For other boiler sizes or operating conditions, consult AMTROL Technical Support.
Air
Separator
System
Supply
Circulator
Air Vent
Extrol
Expansion
Tank
System
Return
Water
Supply
Fill
Valve
Boiler
Extrol floor-standing models are designed for large residential and light commercial
applications. These non-ASME tanks are available in sizes up to 86 gallons and can be
used with high output boilers up to 1,500,000 BTU's. ASME Commercial tanks are also
available and can be found in catalog MC 2682.
Typical Installation
SX Series Specifications
7
Special Application Expansion Tanks
Spring-Loaded
Check Valve Automatic Shut-Off
Valve Spring
Expansion
Bypass
Automatic
Shut-Off Valve
Pressure Plate
Removable
Strainer
Cold Water
Supply
Fill Gate
Stem
O-Ring Seal
1/2˝ Compression
Fitting Connection
System Pressure
Above Diaphragm
Diaphragm
Feet of
Tubing
Nominal Pex Tubing Size
3/8" 1/2" 5/8" 3/4" 1"
1,000 RX-15 RX-15 RX-15 RX-15 RX-15
5,000 RX-15 RX-15 RX-15 RX-30 RX-30
7,500 RX-15 RX-15 RX-30 RX-30 RX-60
10,000 RX-15 RX-30 RX-30 RX-60 RX-60
14,000 RX-15 RX-30 RX-60 RX-60
18,000 RX-30 RX-60 RX-60 RX-60
22,000 RX-30 RX-60 RX-60
30,000 RX-30 RX-60 Contact Amtrol
Sizing based on: Fill Pressure 12 psig; Relief Pressure 30 psig; Average Temperature 120°F;
System filled with water. For glycol applications, consult AMTROL Technical Support.
Sizing
System
Volume
(Gallons)
Average System Operating Temperature
140°F 160°F 180°F 200°F 220°F
10 SE-15 SE-15 SE-15 SE-15 SE-15
20 SE-30 SE-30 SE-30 SE-30 SE-30
30 SE-30 SE-30 SE-60 SE-60 SE-60
40 SE-60 SE-60 SE-60
50 SE-60 SE-60 Contact Amtrol
Sizing based on: 50% Water and Propylene Glycol Max; 25 psig Fill; 50 psig Relief Valve.
For other applications, consult AMTROL Technical Support.
Sizing
RADIANT EXTROL®
For high-efficiency radiant systems.
Plastic liner is compatible with barrier
and non-barrier tubing.
Suitable for use in glycol applications.
Stainless steel connection for
corrosion resistance.
Factory pre-charge: 12 psig.
Maximum working pressure: 100 psig.
Maximum operating temperature: 200°F.
Model
Number
Tank
Volume
(Gallons)
Max. Accept.
Volume
(Gallons)
A
Diameter
(Inches)
B
Height
(Inches)
System
Connection
Shipping
Weight
(lbs.)
RX-15 2.0 0.9 8 13 12 NPTM 5
RX-30 4.4 3.2 11 15 12 NPTM 9
RX-60 10.3 10.3 15 19 34 NPTF 23
Radiant Extrol® Specifications
Note: A standard EXTROL tank is not interchangeable with a FILL-TROL tank.
FT-109 is equivalent to EX-15; FT-110 is equivalent to EX-30;
FT-111 is equivalent to EX-60 and FT-112 is equivalent to EX-90
.
Model
Number
Tank
Volume
(Gallons)
Max. Accept.
Volume
(Gallons)
A
Diameter
(Inches)
B
Height
(Inches)
System
Connection
(NPTF)
Shipping
Weight
(lbs.)
FT-109 2.0 1.0 815 126
FT-110 4.4 2.5 11 17 1210
FT-111 7.4 2.5 11 25 1215
FT-112 14.0 11.3 15 23 1224
Fill-Trol® Specifications
Model
Number
System
Connections
(NPTF)
FILL-TROL
Model
Air Purger
Model
Air Vent
Model
Shipping
Weight
(lbs.)
FT-109-100 1109 443 700-C 10
FT-109-125 114109 444 700-C 10
FT-110-100 1110 443 700-C 14
FT-110-125 114110 444 700-C 14
FT-111-125 114111 444 700-C 18
Combination Packages
SOLAR EXTROL®
For high-efficiency solar systems.
Suitable for use in glycol applications.
Factory pre-charge: 25 psig.
Maximum working pressure: 150 psig.
Maximum operating temperature: 250°F.
FILL-TROL® System
Eliminates the need for a separate,
automatic fill valve.
Tank pressure controls system fill.
Factory pre-charge: 12 psig.
Fully adjustable up to a maximum
working pressure of 100 psig.
Model
Number
Tank
Volume
(Gallons)
Max. Accept.
Volume
(Gallons)
A
Diameter
(Inches)
B
Height
(Inches)
System
Connection
(NPTM)
Shipping
Weight
(lbs.)
SE-15 2.0 1.0 813 125
SE-30 4.4 2.5 11 16 129
SE-60 7.4 2.5 11 23 1214
Solar Extrol® Specifications
For Precise Sizing, visit www.amtrol.com or consult AMTROL Technical Support.
1400 Division Road, West Warwick, RI USA 02893
T: 800.426.8765 F: 800.293.1519
www.amtrol.com
© 2014 AMTROL Inc. MC 2680 (01/14)
Mark of the
Originator
Tanks on Tour
The Tanks on Tour mobile education center is traveling throughout the
United States and Canada demonstrating the very real differences that
have made Extrol® Expansion Tanks the industry standard for over
sixty years.
Tanks on Tour in front of the Amtrol Education Center.