Pycom WIPY3R Double Network (WiFi and Bluetooth) IoT development Module powered by MicroPython User Manual wipy3SpecsheetAugust2017

Pycom Ltd Double Network (WiFi and Bluetooth) IoT development Module powered by MicroPython wipy3SpecsheetAugust2017

Users Manual

ESPcont BlueRGB heart beat  RF High SM8MB flash memory  U.FL          WiPy 3.0 Introducing the WiPy 3.0. The tiny MicroPython enabled Wifi &  Mechanical Size: 42mm x 20mm x 3.5mm (excluding headers) Bluetooth IoT development platform. With a 1KM WiFi range, state of the art Espressif ESP32 chipset and dual processor, the WiPy 3.0 is all about taking the Internet of Things to the next level.  Create and connect your things everywhere. Fast.  WiPy Features Operating temperature: -20 to 85 degrees celsius  3V3 ultra low noise switching regulator    32 dual core micro- roller and WiFi/ tooth 4.2 radio    performance - Powerful CPU, BLE and state of the art WiFi radio. - 1KM Wifi Range - MicroPython enabled     Reset Switch D antenna - Fits in a standard breadboard (with headers)      - Ultra-low power usage: a fraction compared to other connected micro controllers  Processing - Espressif ESP32 chipset - Dual processor + WiFi radio System on Chip - Network processor handles the WiFi connectivity and the IPv6 Interfaces - 2 x UART, 2 x SPI, I2C, I2S, micro SD card - Analog channels: 8x12 bit ADCs - Timers: 4x16 bit with PWM and input capture - DMA on all peripherals - GPIO: Up to 24  stack - Main processor is entirely free to run the user application - An extra ULP-coprocessor that can monitor GPIOs, the ADC channels and control most of the internal peripherals during deep-sleep mode while only consuming 25uA  Use the Pymakr IDE Super easy code editor to write your Python scripts  Quick Verification For easy and fast debugging use the interactive shell that is acces- sible through telnet or one of the serial ports Hash / encryption SHA, MD5, DES, AES WiFi 802.11b/g/n 16mbps Bluetooth Low energy and classic RTC Running at 32KHz Power - 3.3V to 5.5V 3V3 output capable of sourcing up to 500mA Security & Certifications - SSL/TLS support - WPA Enterprise security - FCC - 2AJMTWIPY3R - CE 0700 Memory - RAM: 4MB - External flash: 8MB - Hardware floating point acceleration - Python multi-threading Easy Upload Upload your scripts, and any other files you want to the WiPy 3.0 via the FTP server  Locally or remotely Reset the WiPy 3.0 (you can do it locally, or remotely via Telnet) With  dozens  of  ready  to  use  templates  and  libraries  soon to  be  available  on  the  Pycom  Exchange,  developing  a  new IoT solution is now easier and faster. Additional support for Blynk: SMTP, MQTT, URLLIB, ONEWIRE,  Accelerometer, Event loop MicroPython together with the universal hard- ware API allow us to build a large set of powerful, robust, and portable  libraries  across  hardware platforms.    Distributed and manufactured by Pycom Ltd. Registered office: High Point, 9 Sydenham Road, Guildford, Surrey GU1 3RX, UK Copyright © 2017 by Pycom Ltd. All rights reserved. No part of this document may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or
EU Regulatory Conformance  Hereby, Pycom Ltd declares that the radio equipment type Wipy 3.0 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:www.pycom.io  Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.  CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.  RF Warning Statement  To comply with FCC RF exposure compliance requirements, the antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.  This device is intended only for OEM integrators under the following conditions:  1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna.  As long as two conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed. To ensure compliance with all non-transmitter functions the host manufacturer is responsible for ensuring compliance with the module(s) installed and fully operational. For example, if a host was previously authorized as an unintentional radiator under the Declaration of Conformity procedure without a transmitter certified module and a module is added, the host manufacturer is responsible for ensuring that the after the module is installed and operational the host continues to be compliant with the Part 15B unintentional radiator requirements.  The module is limited to OEM installation ONLY. The module is limited to installation in mobile or fixed application. We hereby acknowledge our responsibility to provide guidance to the host manufacturer in the event that they require assistance for ensuring compliance with the Part 15 Subpart B requirements.  IMPORTANT NOTE: In the event that these conditions cannot be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for reevaluating the end product(including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling  This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: 2AJMTWIPY3R”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.  The following FCC part 15.19 statement has to also be available on the label:  This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.  Manual Information to the End User  The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module.  In the user manual of the end product, the end user has to be informed that the equipment complies with FCC radio-frequency exposure guidelines set forth for an uncontrolled environment.  The end user has to also be informed that any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate this equipment.  The end user manual shall include all required regulatory information/warning as show in this manual.  The maximum operating ambient temperature of the equipment declared by the manufacturer is -20~+85C
 Regulatory statement  This device complies with Part 15 of the FCC Rules and with RSS-247 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  RF Exposure Statement  This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.   Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.   Frequency Band  2400‐2483.5MHZ  EIRP For Internal antenna Bluetooth: -5.24dBm WiFi: 10.81dBm  EIRP For External antenna Bluetooth: 2.93dBm WiFi: 7.99dBm

Navigation menu