Quanta Computer CI2 Wearable ECG Monitoring Device User Manual CI2418 01 V1 0 20140718Wx

Quanta Computer Inc Wearable ECG Monitoring Device CI2418 01 V1 0 20140718Wx

User Manual

CI2418-01_2A ____________________________________________________________________________  QUANTA COMPUTER INC. HUAYA PLANT _________________________________________________________________           Wearable ECG Monitoring Device User Manual     Ver. 1.0               _________________________________________________________________ 2014 Quanta Computer Inc. Huaya Plant  All rights reserved.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 1 INDEX WARNINGS AND REMINDERS ............................................................................. 2 WARNINGS: ........................................................................................................................................................ 2 REMINDERS:....................................................................................................................................................... 3 YEAR OF MANUFACTURE ..................................................................................... 5 SUPPLIER'S DECLARATION ................................................................................. 7 REGULATORY MARKS ......................................................................................... 10 INTRODUCTION ....................................................................................................... 12 EQUIPMENT ............................................................................................................... 13 A.NB / PC ....................................................................................................................................................... 13 EQUIPMENT OPERATING INSTRUCTIONS................................................ 15 A. PERSONAL COMPUTER (NB/ PC) ....................................................................................................... 15 B. QUANTA ECG MONITOR APPLICATION, NYA- DATA- CMD [FOR USE ON PERSONAL COMPUTERS (NB / PC)] ......................................................................................................................... 16 C. NYA BODY MONITOR ........................................................................................................................... 21 D. NYA BODY MONITOR ACCESSORY .................................................................................................. 25 E. ECG ELECTRODES .................................................................................................................................. 26 F. NYA CHARGER ........................................................................................................................................ 27 CLEANING OF THE WIRELESS HOME HEALTH MANAGEMENT SYSTEM ........................................................................................................................ 29 PRODUCT SPECIFICATIONS ............................................................................. 29 PRODUCT LIST ......................................................................................................... 30
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 2 Warnings and Reminders  Warnings:     The NYA  Quanta  Wireless  Home  Health  Management  System  is  to  be  used  for clinical  assessment  and reference only.  The NYA  Quanta Wireless  Home  Health Management System is not intended for diagnostic use.  The NYA Quanta Wireless Home Health Management System consists entirely of sophisticated medical electrical devices so maintenance can only be carried out by professional technicians. Unauthorized disassembly of the device by the user is not allowed.  The NYA Quanta Wireless Home Health Management System must be used with the specified "accessories" and "electrodes". The use of accessories and electrodes from other brands may lead to faulty readings.  Do  not allow  the  metal  connectors to  come  into  contact  with any  kind of power source during use.  Before using the NYA Quanta Wireless Home Health Management System. Please make  sure  that  all  of  the  machine's  indicator  lights  are  clearly  readable  in  the current usage environment.  Damaged or faulty accessories and electrodes should not be used.  When the NYA Quanta Wireless Home Health Management System experiences an error,  it  will  automatically  stop  taking  measurements  and  the  corresponding indicator lights will blink.  When  the  NYA  Quanta  Wireless  Home  Health  Management  System  is  low  on power,  it  will  automatically  stop  taking  measurements  and  the  corresponding indicator lights will be blink.  When  the  NYA  Quanta  Wireless  Home  Health  Management  System  is  taking measurements,  please  try  and  avoid  using  any  instruments  or  devices  that  may affect the accuracy  of the  readings  (e.g. the use of the  blood pressure  meter  will affect the measurement of the pulse).  When  the  NYA  Quanta  Wireless  Home  Health  Management  System  is  taking measurements, please try and avoid using other electronic devices nearby. If it must be  used  with  other  electronic  devices  simultaneously,  please  check  to  make  sure that the NYA Quanta Wireless Home Health Management System is continuing to take measurements normally.  NYA-specific  accessories  are  defined  in  this  user  guide.  The  use  of  accessories from other brands may damage the device.    Do  not  use  the  NYA  Quanta  Wireless  Home  Health  Management  System  in  a flammable environment.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 3 Reminders:     Please  read  through  this  user  guide  carefully  before  using  the  NYA  Quanta Wireless Home Health Management System.  If the NYA Quanta Wireless Home Health Management System  must be used to take measurements over an extended period of time, please inspect the contact point of the electrodes at least once every 8 hours to make sure that the electrodes are in the right position and there is no allergic skin reaction from the user.  Do  not  use  medical  electrical  equipment  such  as  "defibrillators"  when  using  the NYA Quanta Wireless Home Health Management System.  When  the  NYA  Quanta  Wireless  Home  Health  Management  System  is  taking measurements, if a stable reading cannot be taken then stop taking the measurement right away (not everyone is suitable for monitoring with the NYA Quanta Wireless Home Health Management System).  The  NYA  Quanta  Wireless  Home  Health  Management  System  can  only  take measurements when the subject is stationary (e.g. while sitting or lying down) or engaging  in  ordinary  exercise.  Any  activities  not  permitted  by  the  attending physician may affect the accuracy of the measurements.  Do  not  use  the  NYA  Quanta  Wireless  Home  Health  Management  System  in  an excessively humid environment and never submerge it directly under water.    Do not clean or wipe the NYA Quanta Wireless Home Health Management System with corrosive and abrasive cleaning agents.  The NYA Quanta Wireless Home Health Management System consists entirely of sophisticated medical electrical devices so maintenance can only be carried out by professional technicians. Unauthorized disassembly of the device by the user is not allowed.  When  the  NYA  Quanta  Wireless  Home  Health  Management  System  is  low  on power, please insert it in the charger for re-charging as soon as possible.  The disposal of the NYA Quanta Wireless Home Health Management System and its accessories should comply with the relevant local regulations.  The NYA Quanta Wireless Home Health Management System has been tested and certified  to  international  electro-magnetic  compatibility  (EMC)  standards  for medical equipment (EN 60601-1 and EN 60601-1-2) for the user's peace of mind.  The NYA Quanta Wireless Home Health Management System and its accessories should  be  disposed  of  properly.  If  you  are  uncertain  about  the  proper  disposal method, please contact customer service at Quanta Computer Inc. Huaya Plant for assistance.  The  accuracy  of  the  medical  electrical  equipment  may  be  affected  if  used  near high-frequency communications equipment.  Battery Caution Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 4  Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible  for  compliance  could  void  the  user’s  authority  to  operate  the equipment.  This device  complies with part 15  of  the FCC Rules.  Operation  is subject to the following two conditions:   1) this device may not cause interference and 2) this device must accept any interference, including interference that may cause undesired operation of the device.  15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide  reasonable  protection  against  harmful  interference  in  a  residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful interference  to  radio  communications.  However,  there  is  no  guarantee  that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures:  -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. .
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 5 Year of Manufacture  The  year  of  manufacture  label  and  format  of  the  wireless  home  health  management system's body monitor, charger and ECG electrodes are shown below:    Sensor    Charger  Example: If the serial number is “QTCI2C425001” The 7th characters is mean “14” Then the year of manufacture is 2014 AD. In the serial number on the product label, the 7th character starting from the left (“14” in the shown example) represents the sensor and charger's year of manufacture.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 6  ECG Electrodes The  effective  date  of  the  ECG  electrodes  is  labeled  along  the  lower  edge  of  the packaging in impact type (not printed) as shown below:       Example: 220801X 2015-07 Explanation:    220801X  Manufacturer lot number 2015-07  Valid before July 2015
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 7 Supplier's Declaration  The  NYA  Quanta  Home  Health  Management  System  conforms  to  the  international  EN 60601-1  and  EN  60601-1-2  standards  for  electromagnetic  compatibility  with  medical electrical devices and systems.  Emission Testing Compliant Standard  Electromagnetic Environment Guidelines The  recommended  electromagnetic  environment  for  this  instrument  is  shown  in  the table below.    The customer or user should ensure that this instrument is used in the described environment.   RF Emissions CISPR 11  Group 1  Radio-frequency is only used by the internal functions of this instrument. The emission energy is also very low and does not interfere with nearby electronic instruments. RF Emissions CISPR 11  Class B  This instrument is suitable for home use (including residential or other mixed residential/public low-voltage power grids) Harmonic Emissions  IEC 61000-3-2 Voltage Fluctuations/ Flicker Emissions IEC 61000-3-3   Testing  IEC 60601-1-2 testing  Compliant Standard Electromagnetic Environment Guidelines The  recommended  electromagnetic  environment  for  this  instrument  is  shown  in  the table  below.    The  customer  or  user  should  ensure  that  it  is  used  in  the  described environment. Electrostatic Discharge (ESD) IEC 61000-4-2 ±6 kV contact ±8 kV air ±6 kV contact ±8 kV air The floor should be timber, concrete or ceramic tile.    If the floor is covered in a synthetic material then it should have a relative humidity of at least 30%. Power Frequency (50/60Hz)   Magnetic Field IEC 61000-4-8 3 A/m  3 A/m  Power frequency and magnetic field in representative commercial or hospital environments.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 8 Supplier's declaration and guidelines—Electromagnetic Immunity Testing  IEC 60601-1-2 testing  Compliant Standard  Electromagnetic Environment Guidelines The recommended electromagnetic environment for this instrument is shown in the table below.    The customer or user should ensure that it is used in the described environment. No part of the NYA Quanta Wireless Home health management System should be placed near portable and mobile radio-frequency communications equipment.    The recommended safety distance can be calculated using the radio frequency and the following formula. Radio-frequency IEC 61000-4-6  Radio-frequency IEC 61000-4-3 3 V/m   150 kHz to 80 MHz  3 V/m 80 MHz to 2.5 GHz [3] V   [3] V/m Recommended safety distance d=1.17P  d=1.17P  80 MHz to 800MHz d=2.33P  800MHz to 2.5 GHz  P is the maximum output of the transmitter (Unit: Watt) d is the recommended safety distance (Unit: Meter)  The field intensity of the fixed RF transmitter (after an EM site survey) should be lower than the recommended values for the above frequency ranges.  Interference may be produced near instruments that have the following symbol:   The field intensity of fixed RF transmitters (e.g. radio, mobile phone, ham radio, FM and AM radio broadcasts and TV stations) cannot be predicted from the frequency alone.    To evaluate the  EM  field  intensity  of  the  environment,  an  EM  site  survey  may  be  necessary.    If  the measured  field  intensity  for  a  region  exceeds  the  above  recommended  range,  the  device should be observed or checked to make sure it operates normally.    If abnormal operation is observed,  further  action  such  as  adjusting  the  direction  or re-positioning of  the equipment should be taken.    Attention: For frequencies between 80 MHz and 800 MHz, use the higher frequency range.    Attention: These guidelines may not be applicable to all situations.    Electromagnetic waves can be absorbed or reflected by buildings, objects and people.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 9 Recommended safety distance The following table lists the recommended safety distance between the device and mobile RF communications equipment.    The recommended EM environment for the NYA Quanta Wireless Home Health Management System is where RF interference is controlled.    The user should maintain the recommended safety distance with the devices and portable/mobile RF communications equipment listed in the following table (corresponding to the maximum output of the RF transmitter).     Recommended Safety Distance (corresponding to RF transmitter output) Maximum output of RF transmitter (Watt) 150 kHz to 80 MHz d=1.17P 80 MHz to 800 MHz d=1.17P 800 MHz to 2.5 GHz d=2.33P 0.01  0.12  0.12  0.23 0.1  0.37  0.37  0.74 1  1.2  1.2  2.3 10  3.7  3.7  7.4 100  12  12  23  If the maximum output of the transmitter is not shown in the above table, use the formula to derive the recommended safety distance d (Meter) with P (Watt) being the maximum output of the transmitter.    Attention: For frequencies between 80 MHz and 800 MHz, use the higher frequency range.    Attention: These guidelines may not be applicable to all situations.    Electromagnetic waves can be absorbed or reflected by buildings, objects and people.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 10 Regulatory Marks  The Wireless Home Health Management System conforms to the following regulatory requirements. Administrative Regulations on Low Power Radio Waves Radiated Devices (930322) Article 12 Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to an approved low power radio-frequency devices. Article 14 The low power radio-frequency devices shall not influence aircraft security and interfere with legal communications.    If found, the user shall cease operation immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act.    The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.   CE Mark: Indicates that the body monitor has been certified and conforms to EC Directive 93/42/EEC on medical devices.  Type CF applied part  Indicates that the body monitor is classified as electrical or electronic equipment requiring proper disposal (WEEE Directive)  Indicates the manufacturer's catalogue number   Attention: Catalogue  number may  also  be  referred  to  as  the reference number or reorder number.  Indicates the manufacture's serial number.  Indicates the manufacturer's name and address  To  indicate  on  the  rating  plate  that  the  equipment  is  suitable  for alternating current only; to identify relevant terminals.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 11  Indicates  the  need  for  the  user  to  consult  the  instructions  for  use  for important cautionary information such as warnings and precautions that cannot,  for  a  variety  of  reasons,  be  presented  on  the  medical  device itself  Indicates the need for the user to consult the instructions for use.   Indicates the identification of CLASS II EQUIPMENT only
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 12 Introduction   "Electrocardiogram" (ECG) Waveform  Required equipment Remarks Smart phone (E)+  NYA body monitor (G)  ECG electrode (I)  + Accessory (H) Body Monitoring Shirt(J) Choose one of the two measurement options on the left based on the usage requirements, nursing personnel's requirements or user's personal preference.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 13 Equipment A.NB / PC Functions The device requires a commercially available personal computer (NB/PC) with Bluetooth capabilities. In addition to the basic functions of a computer, the installation provides an exclusive application (UI, as below) capable of performing electrocardiogram (ECG) measurements. Doctors and medical staff can effectively monitor health information by uploading the measurements to the main server via Bluetooth.   Quanta ECG Monitor Application UI (for use on NB / PC) Functions The application (UI) can be installed on any personal computer (NB /PC) to provide ECG data measurement functions. With the Quanta ECG Monitor device (B), body monitoring accessories (D), ECG electrode patches (C) , measured data will be uploaded to the server via Bluetooth so doctors and medical staff can conduct carry out remote monitoring.    B. NYA Body Monitor Function The  ECG  signal  measured  through  this  device  is  wirelessly  transmitted  using  low-power Bluetooth technology to  the smart phone  for processing. The data is then uploaded  via 3G wireless network to the cloud server. This device requires the ECG Electrodes  (C)  in  order  to take measurements.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 14  C. NYA Body Monitor Accessory Function When the electrodes are used, this accessory is used to attach the NYA Body Monitor (B) and transmit the ECG signal between electrodes.   Back   Front     D. ECG Electrodes Function Attach to the designated location on the chest in order  to  capture  physiological  ECG  signal  for the NYA Body Monitor (B) for processing and upload.         E. NYA Charger Function Used for charging the NYA Body Monitor (B). The charger has two slots  that  allow  it  to  charge  two Body  Monitor  (B)  units  at  the same time.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 15 Equipment Operating Instructions  A. Personal Computer (NB/ PC)  According to the specifications of individual personal computers (NB / PC).  Operating Instructions:  Start up the computer After starting up your personal computer (NB / PC), users can access the available functions.  Shut down the computer To shut down your personal computer (NB / PC), click Shut Down.  Bluetooth Functions  Install a Bluetooth dongle on your personal computer (NB / PC).  Plug  in  your  Bluetooth  dongle  to  the  USB  port  to  turn  the  Bluetooth functions on or off.  Upon  selecting  and  launching  Bluetooth,  the  Bluetooth  interface  will  be displayed. Click to search for the device.  Your device name will be displayed in the Bluetooth selection field. Click on your device name to add it to the system.  The configuration and connection status will be shown on top of the device name in your list of Bluetooth devices.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 16 B. Quanta ECG Monitor application, NYA- Data- CMD [for use on personal computers (NB / PC)] Operating Instructions:   Ensure that you have completed the installation of the Quanta ECG Monitor. Please refer to the next chapter, “G.    Quanta ECG Monitor Body Monitoring Device" for the instructions and diagrams.  On your computer's desktop, click the NYA-Data-CMD UI icon, as shown, to launch the application.  The following window will be displayed upon launching the application.     Button Function A  Communication Port Settings B  Create New Case C  Subject & Case Management        A B
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 17 1.  Communication Port Settings Set up the com port to receive Vital Sign Sensor data. Click "System"  "Com Port Setting" to open the following window.    Port The system will automatically detect and list the current Com Ports on the computer. Select the Port to connect to.  Baud Rate Select 115200.  Parity Select None.  Date Bits Select 8.  Stop Bits Select 1.  After making the changes, click "Save" to complete. The changes will not take effect if you cancel and exit the screen.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 18 2.  Create New Case Clicking "New Case" will display the following window:  Create a New Case as follows: a. Click "New Case" to display the following window.  Confirm the subject in the Subject field. Enter the Resting HR of the Subject and click "OK". b. Ensure Bluetooth has been properly connected to the Serial Port of the hardware. c. Click "Open" to open the Com Port as shown in the diagram below.    If  correctly  launched,  the  Status  will  change  to  Connected  as  shown  in  the diagram  below.  To  close  the  Com  Port,  click  "Close".  If  during  the measurement process, the Com Port connection disconnects due to instability, the system will close the Com Port automatically.  d. Click "Start" on the left of the screen to connect to the hardware, send out the initializing data and prepare to receive the test data. e. To end the test, click "Stop" on the right of the screen. Upon clicking "Stop", the data automatically save to the database.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 19 f. Screen description:  A. Displays the basic information of the case. B. Displays the time elapsed for the test. C. Displays the battery life of the hardware. D. Displays whether  a Fall Event occurs.  Click  "Cancel" to  execute  Cancel Fall Event command. E. Auto ECG command. By clicking "Auto ECG", the ECG waveform will update  every  3  seconds;  HR,  AAC,  PAC,  PAI,  PAEE  and  battery  will update  every  15  seconds;    and  Steps,  Stride,  Speed,  Calories,  and Distance will update every 60 seconds.  ECG waveform display Enlarge will enlarge the ECG waveform measured.   Change Y-axis range of ECG display On the Y-axis range, right-click to display a selection list. Select Edit as shown in the diagram right.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 20  Correct  the  two  values,  Min  and  Span,  on  the  General  Tab.  Min  is  the starting value of Y-axis; Span is the length of Y-axis.     Battery life display of monitoring device Under normal connection and usage, the battery life symbol will display as follows. Different battery bars represent different battery life. High battery life, estimated usage time of 12 to 16 hours. Medium battery life, estimated usage time of 7 to 11 hours. Low battery life, estimated usage time of 2 to 6 hours. Critical battery life, with less than 1 hour of battery life. Please charge immediately. 4 bars (full)  3 bars  2 bars  1 bar Note: The above battery life display and usage time is for reference only, as the data is obtained by testing on a new product. The actual usage time will  defer  with  different  conditions  such  as  charging  conditions, number of times used, environmental temperature, distance from base station, connectivity, etc.  Condition  Possible Reason  Recommended Actions Data disconnected or omitted while sleeping. The subject turns over or sleeps on one side causing the Quanta ECG Monitor to detach from the accessories or causing poor connection due to pressure from the body. We recommend putting on the physiological monitoring clothing while sleeping. The Quanta ECG Monitor monitoring device is a safe and low power Bluetooth device. The electric wave emitted is weak. If the subject sleeps on one side or wraps one's arms around the body while sleeping, the device may easily become disconnected or obstructed by the body. While sleeping, put the handphone on your headboard or within 1 to 2 meters of the bedside. We recommended placing the handphone at a position higher than the bed. Do not put the handphone on the floor. Refrain from placing the handphone at a position lower than or at the end of the bed.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 21   C  Subject & Case Management   After executing "Subject & Case", the following screen will be displayed:     A. Click "New Subject" button.   B. Enter Name, Sex, Birthday, Height and Weight.   C. Click "Save All" to save into the database. If the Name entered already exists, the system will display the following alert message as shown in the diagram. D. Select the Subject Name in the "Subject Name" field. The subject's test cases will display in the case list below.           C. NYA Body Monitor   External guide to body monitor:    LED status light  Front of Body Monitor Male-end of magnetic clip     Back of Body Monitor                     Waterproof vent Bluetooth pairing button Charger detection port
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 22  Bluetooth matching (These settings will be set by the service representative)   (1)  When  the  “Smart  Phone”  or  “NYA  Monitor”  is  used  for  the  first  time  or updated they must be paired.   (2)  Open the smart  phone and  make sure that  it has  Bluetooth enabled  (See E. Smart Phone Instructions).   (3) Use the pin to press the Bluetooth pairing button on the “NYA Monitor” to start pairing.   (4)  During  the  pairing  process,  the  LED  status  light  will  alternatively  blink green/orange for 1 minute.   (5)  Once pairing is successful, the green LED will stay lit for 5 seconds and the mobile phone will show that it is connected.   (6)  If pairing  fails, the LED status light on the monitor will alternatively blink green/orange for 1 minute then stop pairing and searching. All lights will then go out.    Instructions for the Body Monitor   (1)  Clip  the  ECG  electrode's  male  connector  to  the  female  connector  on  the accessory as shown below:      (2)  Remove  the  paper  strip  from  the  ECG  electrode.    For  step  1,  attach  the device-side to the lower edge of the left chest. For step 2, attach the wire-side to the lower edge of the right collarbone as shown below:      Device-side Wire-side
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 23 Attention: The ECG electrodes and accessory must not be worn in the following manner  for  an  extended  period  of  time.  This  prevents  the  dangling  end from short-circuiting with any power supply.        Wire-side hanging loose     Device-side hanging loose  (3) Clip the male magnetic male connector on the monitor to the female connector on the accessory as shown below.    Note: The circular red or blue mark on the monitor must point upwards and must not be upside-down. Please see below.     Circular mark pointing upwards      (4) Launch the NYA-Data-CMD Application” on the PC/NB (Please see the previous section B. ) shown below:    NYA-Data-CMD Application icon    Note: Before launching the application, only one body monitor can be used/activated at any time.    Using two monitors at the same time will cause the App system to fail. (5) Once the app is running, please see the instructions in section B.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 24   Other body monitor information:   (a) If the monitor has a low battery, the orange LED light will blink.   (b) When the monitor is placed on the accessory (or body monitoring shirt), the green LED light on the monitor will blink for 5 seconds before going out.   (c) During standby and measurement, the monitor's status light will not be shown except when power is blow.   (d) When  the  monitor  is  being  charged  in  the  charger,  the  status  lights  will remain off.   (e) As long as the monitor is not on the accessory, tapping the monitor twice will cause the green LED to come on. The monitor will then start transmitting data (the smart phone app must be running and connected). Once the transmission is complete, the green LED light goes out. If the smart phone does not have the app running, the green LED will stay on for two minutes then go out.   (f) When the ECG electrode falls from the user or the monitor becomes detached from  the  accessory,  the  green  LED  on  the  monitor  blinks  once  every  3 seconds.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 25 D. NYA Body Monitor Accessory  Used for connecting the body monitor and ECG electrodes so the best ECG signal can be  acquired.  Please  see  the  previous  section  "“G.  NYA  Body  Monitor"  for  further information and graphics.    Magnetic Clip Female Connector  ECG wiring Pressure Clip Female Connector     Front of accessory  Reverse of accessory  Attention:   If  any  wear  or  damage  to  the  wire cladding  is  found during use,  replace immediately.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 26 E. ECG Electrodes The ECG Electrodes are conductors placed on the skin of the chest for transmitting the signal  generated  by  the  beating  of  the  heart.  The  signal  is  transmitted  to  the  body monitor for amplification and processing into the ECG signal.    Pressure Clip Male Connector   Front of electrodes    Back of electrodes  Attention:    Before attaching the ECG electrodes, make sure that the skin surface is clean. It may necessary to wipe the skin clean with a wet towel or alcohol swabs then wait for it to dry before attachment.    Electrodes are not re-usable.    If the skin at the attachment point shows signs of a rash/blisters/reddening or other discomfort, please contact the medial personnel or physician.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 27 F. NYA Charger Charger function:    Magnetic clip female connector  Charger detection probe       LED status light (1)  The magnetic clip male-connector on the monitor and the magnetic clip female connector  of  the  charger  clips  with  each  other.  Pay  attention  to  the  direction when  placing  the  monitor  on  the  charger.  The  charger  detection  port  on  the monitor  must  be  aligned  with  the  charger  detection  probe  on  the  charger  as shown below.   Charger detection probe     Charger detection port (2)  When the charger is closed and plugged into power mains, the orange LED will light up when it is charging normally as shown below.     During charging the orange LED stays on.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 28  (3)  Once the monitor is fully charged, the orange LED on the charger goes out and the green LED comes on. Remove the charger from the socket, open the cover of the charger and insert finger into the ventral groove to pick up the monitor for use as shown below:       The green LED lights up after charging  Insert finger into ventral groove and pick up monitor.  Other charger functions   (1)  When the charger is plugged into the socket by itself (with no monitors), the orange LED light lights up for two seconds.   (2)  Place the monitor on the charger and connect the transformer to the power socket. The orange LED light on the charger will now light up.   (3)  Once the monitor has  been  fully  charged, the orange LED is extinguished and the green LED slights up.
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 29 Cleaning of the Wireless Home Health Management System    Item  Model Name  Cleaning Method Body Monitor  NYA Target  Wipe with dry cloth Charger  NYA Charger  Wipe with dry cloth Accessory (S)  NYA Patch S Wipe with damp cloth Accessory (M)  NYA Patch M Accessory (L)  NYA Patch L  Product Specifications  HR Monitor   Measuring Lead : Lead I  HR Range : 30~240  Frequency response : 0.1~40Hz  Heart rate accuracy : ±3 or ±3%  Sampling rate : 256Hz Activity   G-sensor (3 axis) : ±8g  G-sensor sampling rate : 52Hz Radio   Bluetooth 3.0+EDR    Tx: 0 dbm  Transmission range : 10 meters Battery   Lithium polymer battery 3.7V/140 mAh  Battery life : about 15 hours under measuring mode (Based on link with iPhone and App on) Operating Temperature  5°C ~ 40°C
 QUANTA COMPUTER INC. Wireless Home Health Management System ____________________________________________________________________________ ___________________________________________________________________________ User Manual V1.0  Page: 30 Product List  Part Name/Model    Part Description

Navigation menu