Quanta LI170 Test Operation Guide
Version 0.3
Oct. 07, 2012
Winn
Contents
1.
Introduction.................................................................................................................................... 3
2.
Test Environment ............................................................................................................................ 3
2.1.
Uninstallation ......................................................................................................................... 3
2.1.1.
Windows 7 (32 bit) ................................................................................................................. 3
2.2.
Installation of drivers .............................................................................................................. 5
2.2.1.
Windows 7 (32 bit) ................................................................................................................. 5
3.
Operation of Connection Manager .................................................................................................11
3.1.
Windows 7 (32 bit) ................................................................................................................11
3.1.1.
Basic Configuration................................................................................................................11
3.1.2.
Extended Information ............................................................................................................13
3.1.3.
LTE Manager ..........................................................................................................................15
3.1.4.
Manual PLMN........................................................................................................................16
3.1.5.
Change to Commercial Mode.................................................................................................17
3.1.6.
Disable Polling .......................................................................................................................18
3.1.7.
PIN Management...................................................................................................................19
3.1.8.
Automatic Connect Mode ......................................................................................................20
3.1.9.
Device Location .....................................................................................................................21
3.1.10.
Help.......................................................................................................................................22
3.1.11.
Reset .....................................................................................................................................23
4.
Diagnostic Tool...............................................................................................................................24
4.1.
MsgView ...............................................................................................................................24
4.2.
DbgView................................................................................................................................25
5.
Firmware Upgrade .........................................................................................................................26
5.1.
Image Burn Tool.....................................................................................................................26
6.
OMA-DM .......................................................................................................................................30
6.1.
Mandatory Configuration.......................................................................................................30
6.2.
How to Enable/Disable APN...................................................................................................31
6.3.
How to Modify OMA-DM Server URL .....................................................................................33
6.4.
How to Online Enable/Disable Internet APN ..........................................................................35
6.5.
How to Enable/Disable OMA-DM log .....................................................................................36
6.6.
How to Use VI editor..............................................................................................................37
Page 1
Revision History
Version
Release Date
Description
st
0.1
0.2
Oct. 02, 2012
Oct. 04, 2012
1 Test Operation Guide Release
Add chapter 6.
0.3
Oct. 07, 2012
Draft
Page 2
1. Introduction
This document gives the guidance on how to test Quanta devices.
2. Test Environment
Quanta LI170 device supports Windows XP, Windows Vista (32 bit), and Windows 7 (32 bit) operating
system. It’s recommended to install Quanta LI170 software in Windows 7 32-bit OS.
2.1. Uninstallation
In order to install latest version of software, uninstallation of previous version is required, including
drivers, connection manager, and corresponding software tools.
2.1.1. Windows 7 (32 bit)
1.
Please click
StartProgramsAltair SemiconductorLTE
ALT3100Uninstall
2.
Please click “Yes (Y)” button.
Page 3
3.
Please click “Uninstall” button.
4.
Please wait a few seconds to complete
uninstallation.
5.
Please click “Close” button.
6.
Please click “OK” button.
7.
Please click
“StartProgramsAltair SemiconductorLTE
ALT3100HLVUSBUninstall”.
8.
Please click “YES (Y)” button.
9.
Please reboot your computer after you have
completed the uninstallation.
Page 4
2.2. Installation of drivers
2.2.1. Windows 7 (32 bit)
1.
Please double clicks on “Altair(Quanta) Tool
Package v1.0.0.exe” to start installation.
2.
Please click “Next >” button.
3.
Please click “Install” button.
4.
It will take a few minutes to complete
installation.
5.
Please click “Next >” button.
Page 5
6.
Please check “I accept the terms in the license
agreement”.
7.
Please click “Next >” button.
8.
Please select “Full Installation” type.
9.
Please click “Next >” button.
10. Please click “Next >” button.
Page 6
11. Please click “Install” button.
12. Please click “Next >” button.
13. Please click “Finish” button.
Page 7
14. Please click “Next >” button.
15. Please check “I accept the terms in the license
agreement”.
16. Please click “Next >” button.
17. Please click “Install” button.
Page 8
18. Please click “Continue to install driver anyway
(I)”.
19. Please click “Continue to install driver anyway
(I)”.
20. Please click “Continue to install driver anyway
(I)”.
21. Please click “Continue to install driver anyway
(I)”.
22. Please un-check “Launch “Hostless Image
Burn””.
23. Please click “Finish” button to complete driver
installation.
24. Please click “OK” button.
25. Please click “Finish” button.
Page 9
26. Please plug in Quanta device and please be
patient and wait a few minutes to complete
driver installation.
27. Please click “Close (C)” button.
28. Please reset Quanta device (take out and plug in
the usb cable), it will take about 50 seconds for
Quanta embedded system to be ready.
Page 10
3. Operation of Connection Manager
3.1. Windows 7 (32 bit)
3.1.1. Basic Configuration
1.
In order to get information from our
embedded connection manager, it’s
mandatory to configure as the following
instructions.
2.
Please click
StartProgramsAltair SemiconductorLTE
ALT3100Connection Manager.
3.
Please right click on top of connection manager
and select
OptionsDevice LocationTechnician PC.
4.
Connection manager will pop out window for
you to enter IP and port.
5.
Please enter IP address “10.0.0.1”. (see NOTE)
6.
Please click “OK” button.
NOTE: If you have successfully installed Quanta
LI170 device, the embedded module will generate
DHCP server and its IP address is “10.0.0.1”.
Meanwhile, our Quanta device will get a DHCP
address “10.0.0.133” automatically.
Page 11
7.
Please check if connection manager shows
device information correctly and the red Altair
logo turns into yellow color.
Page 12
3.1.2. Extended Information
1.
Please right click on top of connection manager
and select
ViewExtended Information.
2.
Connection manager will pop out “Extended
Information” window.
3.
It’s NOT mandatory to set up this
“Configuration” tab, connection manager will
scan all the supported frequency bands and try
to connect to the network.
Page 13
4.
The “Extended Data” tab shows information of
Connection Status, APN, Transmission mode,
Bandwidth, DL EARFCN, Band, PLMN and
Physical Cell ID and so on.
5.
The “At Commands” tab will allow you to send
AT Commands sets to configure supported
functional parameters or to get supported
information you want.
Page 14
3.1.3. LTE Manager
1.
Please right click on top of connection manager
and select
ViewLTE Manager.
2.
Connection manager will pop out a “Supervisor
Password” window.
3.
Please input “123456” and click “OK” button.
4.
It will pop out a “LTE Manager” window.
5.
LTE Manager shows information about
GeneralInfo, LogCreator, Dispatcher, Relay, and
GPS Tool.
Page 15
3.1.4. Manual PLMN
1.
Please right click on top of connection manager
and select
Manual PLMN.
2.
Connection manager will pop out a “Plmn
Search” window.
3.
It’s not necessary for you to select PLMN
manually if you want to connect to network.
Page 16
3.1.5. Change to Commercial Mode
1.
Please right click on top of connection manager
and select
“Change to Commercial Mode”.
2.
Connection manager will pop out a “User Mode
Changed” dialog.
3.
Please click “YES (Y)” button.
4.
Please wait a few seconds for device to be
ready.
Page 17
3.1.6. Disable Polling
1.
Please right click on top of connection manager
and select
“OptionsDisable Polling”.
2.
Connection manager will stop searching for
available network.
Page 18
3.1.7. PIN Management
1.
Please right click on top of connection manager
and select
“OptionsPIN ManagementPIN Information”
to get PIN information.
2.
Connection manager will pop out “PIN
Information” window.
3.
Please click “OK” button.
4.
You also can enable PIN usage by right click on
top of connection manager and select
“OptionsPIN ManagementEnable PIN
Usage”.
5.
Please input correct PIN code and click “OK”
button.
Page 19
3.1.8. Automatic Connect Mode
1.
Please right click on top of connection manager
and select
“OptionsAutomatic Connect Mode” to switch
connection manager from manual connect
mode to automatic connect mode.
2.
Connection manager will automatically connect
to network.
Page 20

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Create Date                     : 2012:11:09 19:38:44+08:00
Modify Date                     : 2012:11:09 19:40:06+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2012:11:09 19:40:06+08:00
Format                          : application/pdf
Document ID                     : uuid:2cd2cb3b-76fa-48db-b229-33da59f18a34
Instance ID                     : uuid:6c1287a4-3219-4545-a1fc-9b1747328a16
Producer                        : doPDF Ver 7.2 Build 376 (Windows XP Professional Edition  (SP 3) - Version: 5.1.2600 (x86))
Page Count                      : 21
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HFS-LI170

Navigation menu