Quantum Scalar I500 Users Guide User’s

2015-07-28

: Quantum Quantum-Scalar-I500-Users-Guide-780327 quantum-scalar-i500-users-guide-780327 quantum pdf

Open the PDF directly: View PDF PDF.
Page Count: 570

DownloadQuantum Quantum-Scalar-I500-Users-Guide- Scalar I500 User’s Guide  Quantum-scalar-i500-users-guide
Open PDF In BrowserView PDF
User’s Guide User’s Guide User’s Guide User’s Guide User’s Guide

Quantum Scalar i500 Tape Library

Scalar i500
6-01210-06 B

Scalar i500 User’s Guide, 6-01210-06, Rev. B, February 2014, Made in USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied,
including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum
Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
Copyright 2014 by Quantum Corporation. All rights reserved.
Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior written
authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of the law.
TRADEMARK STATEMENT
Quantum, the Quantum logo, and Scalar are registered trademarks of Quantum Corporation in the USA and other
countries. LTO and Ultrium are trademarks of Quantum, IBM, and HP in the USA and other countries.
All other trademarks are the property of their respective companies.

Contents

Preface

Chapter 1

1

Description

10

Intelligent Storage............................................................................................ 11
Library Configuration ..................................................................................... 11
Modules............................................................................................................. 15
Control Module......................................................................................... 16
Expansion Modules.................................................................................. 16
Stackability ................................................................................................ 16
Front Panel Components ................................................................................ 18
Access Door ............................................................................................... 18
I/E Station ................................................................................................. 19
Operator Panel .......................................................................................... 19
Front Power Button .................................................................................. 20
Back Panel Components ................................................................................. 20
Rear Power Switches................................................................................ 21
Power System............................................................................................ 22
Library Control Blade .............................................................................. 24
Fibre-Channel Input/Output Blades..................................................... 26
Robotic System and Barcode Scanner........................................................... 29
Tape Drive Support ......................................................................................... 30

Scalar i500 User’s Guide

iii

Library Features ............................................................................................... 31
User Interface ............................................................................................ 31
Partitions .................................................................................................... 31
Control Path Modification....................................................................... 32
Support for WORM .................................................................................. 32
Licensable Features.......................................................................................... 32
Understanding the Location Coordinates .................................................... 32
Modules...................................................................................................... 34
Columns ..................................................................................................... 34
Slots............................................................................................................. 34
Tape Drives................................................................................................ 34
Fibre Channel I/O Blades........................................................................ 34
Ethernet Expansion Blades...................................................................... 35
Power Supplies.......................................................................................... 35
Understanding Logical Element Addressing .............................................. 35
Tape Drive Logical Element Addressing .............................................. 35
Cartridge Slot Logical Element Addressing ......................................... 36

Chapter 2

Understanding the User Interface

39

Common User Interface Elements................................................................. 40
System Summary and Subsystem Status .............................................. 42
Home Page................................................................................................. 43
Operator Panel.................................................................................................. 43
Operator Panel Keypads.......................................................................... 44
Operator Panel Indicates Intervention Required ................................. 44
Web Client ........................................................................................................ 44
Menu Trees ....................................................................................................... 45
User Privileges.................................................................................................. 50
User Access ....................................................................................................... 51

Chapter 3

Configuring Your Library

52

About the Setup Wizard ................................................................................. 53
Using the Default Administrator Account............................................ 54
Completing the Library Configuration With Menu Commands....... 54
Using the Setup Wizard .................................................................................. 55
Default Configuration Settings ............................................................... 57
Setup Wizard Tasks.................................................................................. 57
Accessing the Web Client ............................................................................... 59

Scalar i500 User’s Guide

iv

Managing the Network ................................................................................... 59
Modifying Network Settings................................................................... 60
Enabling SSL.............................................................................................. 62
Configuring SNMP Settings on the Library.......................................... 63
Working With Partitions................................................................................. 68
Automatically Creating Partitions ......................................................... 70
Manually Creating Partitions.................................................................. 71
Mixing Tape Drive Types Within Partitions......................................... 73
Modifying Partitions ................................................................................ 73
Deleting Partitions .................................................................................... 74
Changing Partition Access ...................................................................... 75
Taking a Partition Online or Offline ...................................................... 76
Disabling/Enabling Manual Cartridge Assignment ........................... 77
Configuring Cleaning Slots ............................................................................ 78
Configuring I/E Station Slots......................................................................... 79
Configuring Zero I/E Station Slots ........................................................ 82
Setting Tape Drive Parameters ...................................................................... 83
Working With Control Paths.......................................................................... 86
Obtaining and Installing a License Key........................................................ 88
About License Keys .................................................................................. 89
Viewing Licenses and License Keys....................................................... 90
Obtaining a License Key .......................................................................... 90
Applying a License Key ........................................................................... 91
Setting Customer Contact Information......................................................... 92
Configuring the Library E-mail Account ..................................................... 92
Working With RAS E-mail Notifications...................................................... 94
Creating RAS E-mail Notifications ........................................................ 95
Modifying RAS E-mail Notifications ..................................................... 96
Deleting RAS E-mail Notifications......................................................... 96
Working With User Accounts ........................................................................ 97
Local Authentication vs. Remote Authentication ................................ 97
About Local User Accounts..................................................................... 97
Creating Local User Accounts ................................................................ 98
Modifying Local User Accounts ............................................................. 98
Deleting Local User Accounts................................................................. 99
Configuring LDAP ................................................................................... 99
Configuring Kerberos ............................................................................ 104
Setting the Date, Time, and Time Zone ...................................................... 106
Setting the Date and Time Manually ................................................... 107
Setting the Date and Time Using the Network Time Protocol ........ 107
Setting the Time Zone ............................................................................ 108
Setting Daylight Saving Time ............................................................... 108
Working With FC I/O Blades ...................................................................... 109

Scalar i500 User’s Guide

v

Configuring FC I/O Blade Ports .......................................................... 110
FC I/O Blade Internal Virtual Port for Media Changers .................. 111
Configuring FC I/O Blade Channel Zoning....................................... 111
Managing FC Hosts and Host Mapping ............................................. 113
Enabling/Disabling FC Host Mapping ............................................... 113
Viewing FC Host Information .............................................................. 114
Creating, Modifying, and Deleting an FC Host Connection ............ 114
Host Mapping - Overview..................................................................... 116
Host Mapping Vs. Channel Zoning ..................................................... 117
Configuring Host Mapping................................................................... 118
Configuring FC Host Port Failover ...................................................... 119
Repairing and Enabling a Failed Target Port ..................................... 121
Working With Data Path Conditioning............................................... 123
Configuring Library Security Settings ........................................................ 124
Configuring the Internal Network .............................................................. 125
Configuring System Settings........................................................................ 126
User Session Timeout (minutes) ........................................................... 126
Tape Drive Logical SN Addressing ..................................................... 127
Manual Cartridge Assignment ............................................................. 128
Disable Remote Service User ................................................................ 128
Enable SSL................................................................................................ 128
Enable SNMP V1/V2 ............................................................................. 129
Enable IPv6 .............................................................................................. 129
Enable SMI-S............................................................................................ 129
Unlabeled Media Detection................................................................... 129
Auto-Ticket Closure ............................................................................... 131
Configuring the Library for FIPS.......................................................... 131
Enabling and Disabling FIPS Mode on HP LTO-5 Tape Drives ...... 131
Viewing FIPS Status on the Library ..................................................... 132
Configuring Operator Panel Display Settings ........................................... 133
Registering the Library.................................................................................. 133

Chapter 4

Advanced Reporting

134

About the Advanced Reporting License .................................................... 135
Working With Advanced Reporting Reports ............................................ 136
Configuring the Drive Resource Utilization Report.......................... 136
Configuring the Media Integrity Analysis Report............................. 138
Using Advanced Reporting Templates ............................................... 140
Loading and Reloading Advanced Reporting Data .......................... 141
Deleting Advanced Reporting Data..................................................... 141
Saving and E-mailing Report Data Files ............................................. 142
Scalar i500 User’s Guide

vi

Configuring and Viewing the Media Security Log................................... 143
Viewing the Media Usage Log..................................................................... 144
Automatically E-mailing Advanced Reporting Reports and Logs......... 145

Chapter 5

Capacity on Demand

147

Chapter 6

Storage Networking

149

About the Storage Networking License...................................................... 150
Configuring Control Path Failover.............................................................. 150
Forcing Control Path Failover............................................................... 151
Configuring Data Path Failover................................................................... 154
Enabling Data Path Failover ................................................................. 155
Forcing Data Path Failover.................................................................... 157
Configuring Host Access .............................................................................. 160
Registering a Host for Host Access ...................................................... 161
Enabling Tape Drives for Host Access ................................................ 162
Mapping a Host to Tape Drives and Partitions.................................. 163
Modifying a Host.................................................................................... 163
Deleting a Host........................................................................................ 164

Chapter 7

Encryption Key Management

165

KMIP-compliant Encryption Key Management........................................ 167
General Notes About Encryption on the Library............................... 168
About the EKM License ......................................................................... 168
Configuring Encryption Key Management on the Library ..................... 169
Using EKM Path Diagnostics ................................................................ 183
Differences Between Manual and Automatic EKM Path
Diagnostics ....................................................................................... 184
Using Manual EKM Path Diagnostics ................................................. 185
Using Automatic EKM Path Diagnostics ............................................ 186
Viewing and Changing the Active Key Server................................... 187
Viewing Tape Drive Encryption Settings............................................ 188
Performing Scalar Key Manager Functions on the Library.............. 188
FIPS-Certified Encryption Solution............................................................. 199
Configuring the Library for FIPS.......................................................... 200

Scalar i500 User’s Guide

vii

Enabling and Disabling FIPS Mode on HP LTO-5 and LTO-6
Tape Drives....................................................................................... 201
Viewing FIPS Status on the Library ..................................................... 202

Chapter 8

Extended Data Lifecycle Management

203

About EDLM .................................................................................................. 204
Cleaning for EDLM Drives ........................................................................... 207
Incomplete EDLM Scans ............................................................................... 207
Configuring EDLM................................................................................. 207
Pausing EDLM Scans on Partitions...................................................... 222
Running Manual EDLM Tests .............................................................. 224
Working With EDLM Test Results....................................................... 226
Testing Suspect EDLM Drives .............................................................. 235

Chapter 9

Running Your Library

237

Powering on the Library ............................................................................... 238
Shutting Down, Powering Off, and Completely Removing Power ....... 238
Restarting the Library.................................................................................... 239
Logging In ....................................................................................................... 239
Logging In When LDAP or Kerberos is Enabled ............................... 240
Logging Out.................................................................................................... 240
Performing Media Operations ..................................................................... 241
Importing Media..................................................................................... 242
Bulk Loading ........................................................................................... 246
Moving Media ......................................................................................... 248
Exporting Media ..................................................................................... 249
Loading Tape Drives .............................................................................. 251
Unloading Tape Drives.......................................................................... 252
Taking a Tape Drive Online or Offline................................................ 253
About Cleaning Tape Drives........................................................................ 254
Enabling AutoClean ............................................................................... 255
Viewing the Cleaning Count................................................................. 256
Using Valid Cleaning Media................................................................. 256
Importing Cleaning Media .................................................................... 256
Exporting Cleaning Media .................................................................... 258
Manually Cleaning Tape Drives........................................................... 260
About Tape Drive Operations...................................................................... 261

Scalar i500 User’s Guide

viii

Locking and Unlocking the I/E Stations .................................................... 262
Controlling FC I/O Blade Power................................................................. 263

Chapter 10

Getting Information – Logs and Reports

265

Viewing Information About the Scalar i500............................................... 266
Viewing the System Information Report.................................................... 267
Viewing the Library Configuration Report................................................ 268
Viewing the Network Settings Report ........................................................ 271
Viewing Logged-in Users ............................................................................. 272
Viewing the All Slots Report ........................................................................ 272
Viewing, Saving, and E-mailing Library Logs .......................................... 273
Viewing FC I/O Blade Information ............................................................ 275
Viewing FC I/O Blade Port Information.................................................... 276

Chapter 11

Updating Library and Tape Drive Firmware

278

Upgrading Library Firmware ...................................................................... 279
Upgrading Tape Drive Firmware................................................................ 281
Using an Image File to Upgrade Tape Drive Firmware.................... 282
Downgrading IBM LTO-4 Tape Drive Firmware .............................. 283
Autoleveling Tape Drive Firmware ............................................................ 283
Uploading Tape Drive Firmware Used in Autoleveling .................. 284
Deleting Tape Drive Firmware Used in Autoleveling ...................... 284

Chapter 12

Installing, Removing, and Replacing

286

Taking the Library Online/Offline ............................................................. 288
Taking a Library Online......................................................................... 288
Taking a Library Offline ........................................................................ 289
Cabling the Library........................................................................................ 289
Specific Instructions for LTO-5 and LTO-6 Tape Drives .................. 289
Cabling Libraries With SCSI Tape Drives ........................................... 293
Cabling Libraries With SAS Tape Drives ............................................ 298
Cabling Libraries With Fibre Channel Tape Drives Connected
Directly to a Host or Switch ........................................................... 303
Cabling Libraries With Fibre Channel Tape Drives Connected to Fibre
Channel I/O Blades......................................................................... 308
Recommended Library Cabling for FC I/O Blades........................... 313
Scalar i500 User’s Guide

ix

Cable Management Guidelines.................................................................... 316
Cable Management Kit .......................................................................... 316
Managing Power Cords ......................................................................... 317
Managing Ethernet Cables .................................................................... 320
Installing a Stand-Alone 5U Control Module ............................................ 325
Installing a New Multi-Module Library Configuration........................... 326
Preparing to Install a Multi-Module Library ...................................... 327
Installing the Expansion Module ......................................................... 332
Installing the Control Module............................................................... 336
Preparing to Use the Multi-Module Library....................................... 336
Adding Expansion Modules to an Existing Library ................................. 338
Preparing to Install an Additional Expansion Module ..................... 340
Unstacking the Existing Modules......................................................... 343
Installing the New 9U Expansion Module.......................................... 347
Preparing to Use the Library................................................................. 353
Preparing to Remove or Replace a Module ............................................... 356
Permanently Removing Expansion Modules From an Existing Library364
Removing the Expansion Module ........................................................ 365
Preparing to Use the New Library Configuration ............................. 370
Replacing the Control Module..................................................................... 376
Removing the Control Module ............................................................. 377
Replacing the Control Module.............................................................. 380
Preparing to Use the Control Module ................................................. 385
Special Instructions for Replacing a Control Module in a Library
Running SKM................................................................................... 386
Replacing an Expansion Module ................................................................. 388
Removing the 9U Expansion Module.................................................. 390
Replacing the 9U Expansion Module .................................................. 394
Preparing to Use the 9U Expansion Module ...................................... 400
Removing and Replacing the Library Control Blade and LCB Compact
Flash Card ................................................................................................ 402
Replacing the LCB/Compact Flash Card or Compact Flash Card
Only ................................................................................................... 402
Replacing the LCB Only ........................................................................ 412
Adding, Removing, and Replacing Power Supplies ................................ 414
Adding a Redundant Power Supply.................................................... 414
Permanently Removing a Redundant Power Supply ....................... 415
Removing and Replacing a Power Supply ......................................... 416
Installing the Library in a Rack.................................................................... 417
Preparing for Installation....................................................................... 418
Installing the Rackmount Shelves ........................................................ 423
Preparing Modules for Rack Installation ............................................ 426
Installing the Bottom Module in the Rack .......................................... 427

Scalar i500 User’s Guide

x

Installing Additional Modules Into the Rack ..................................... 431
Adding, Removing, and Replacing Tape Drives....................................... 438
Adding a Tape Drive.............................................................................. 438
Permanently Removing a Tape Drive ................................................. 440
Removing and Replacing a Tape Drive............................................... 441
Adding, Removing, and Replacing FC I/O Blades .................................. 443
Read This First: Complete Installation Steps ...................................... 446
Adding an FC I/O Blade ....................................................................... 448
Removing an FC I/O Blade................................................................... 452
Replacing an FC I/O Blade ................................................................... 453
Adding, Removing, and Replacing the FC I/O Fan Blade ...................... 454
Adding an FC I/O Fan Blade................................................................ 455
Removing an FC I/O Fan Blade ........................................................... 457
Replacing an FC I/O Fan Blade............................................................ 457
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade.. 458
Cabling a 5U Library for Ethernet Connectivity ................................ 460
Installing the Ethernet Expansion Blade ............................................. 461
Cabling the Ethernet Expansion Blade ................................................ 468
Permanently Removing or Relocating an Ethernet Expansion
Blade .................................................................................................. 472
Replacing an Ethernet Expansion Blade in the Same Location........ 474
Power Cycling the Ethernet Expansion Blade.................................... 474
Viewing Ethernet Connectivity ............................................................ 475
Ethernet Expansion Blade Status LEDs ............................................... 475
Preparing the Library for Moving or Shipping ......................................... 478

Chapter 13

Troubleshooting

480

Quantum’s Knowledge Base ........................................................................ 481
About RAS Tickets......................................................................................... 481
Viewing RAS Tickets.............................................................................. 482
Resolving and Closing RAS Tickets .................................................... 483
Closing RAS Tickets Automatically ..................................................... 485
Capturing Snapshots of Library Information ............................................ 485
Saving and E-mailing the Library Configuration Record ........................ 486
E-mailing the Configuration Record.................................................... 487
Saving the Configuration Record ......................................................... 488
Saving and Restoring the Library Configuration...................................... 488
Saving the Library Configuration ........................................................ 489
Restoring the Library Configuration and Library Firmware ........... 489
Troubleshooting “Library Not Ready” Messages ..................................... 490
Duplicate Devices Discovered ..................................................................... 491
Scalar i500 User’s Guide

xi

Duplicate Media Changer Devices Discovered......................................... 492
Identifying Tape Drives ................................................................................ 492
Retrieving Tape Drive Logs.......................................................................... 495
Retrieving Tape Drive Sled Logs ................................................................. 496
Identifying FC I/O Blades ............................................................................ 496
Permanently Removing FC I/O Blades...................................................... 497
Resetting FC I/O Blade Ports....................................................................... 498
Viewing and E-Mailing the Command History Logs............................... 499
Interpreting LEDs .......................................................................................... 500
Blade Status LEDs................................................................................... 500
Blade Port LEDs ...................................................................................... 503
Servicing the LCB Based on LED Status.............................................. 505
Tape Drive LEDs..................................................................................... 505
Tape Drive Fibre Port Link LED........................................................... 507
Power Supply LEDs ............................................................................... 508
Using the Installation Verification Test ...................................................... 509
Viewing the IVT Logs ............................................................................ 511
Saving and E-mailing the IVT Logs ..................................................... 511
Running Library Demo.......................................................................... 512
Configuring the Internal Network .............................................................. 513
Library Diagnostics........................................................................................ 513
Drive Diagnostics........................................................................................... 514
Drive Tests ............................................................................................... 514
Media Tests .............................................................................................. 515
Ethernet Expansion Blade Control ....................................................... 516
Robotics Diagnostics...................................................................................... 517

Chapter 14

Working With Cartridges and Barcodes

518

Handling Cartridges Properly ..................................................................... 519
Write-Protecting Cartridges ......................................................................... 520
Barcode Label Requirements........................................................................ 520
Supported Barcode Formats......................................................................... 521
Installing Barcode Labels .............................................................................. 522

Appendix A

Library Specifications

524

Supported Components ................................................................................ 524
Library Capacity............................................................................................. 526
Environmental Requirements ...................................................................... 527

Scalar i500 User’s Guide

xii

Electrical Requirements ................................................................................ 527
Dimensions ..................................................................................................... 528
Component Weights...................................................................................... 528
Library Power Consumption and Heat Output ........................................ 529

Appendix B

Glossary

Scalar i500 User’s Guide

TapeAlert Flag Descriptions

531

541

xiii

Tables

Scalar i500 User’s Guide

Table 1

Web Client Menus...................................................................... 46

Table 2

Operator Panel Menus............................................................... 48

Table 3

Number of Partitions Supported ............................................. 69

Table 4

Number of I/E Station Slots Available ................................... 81

Table 5

Control Path Assignment During Partition Creation ........... 86

Table 6

Available Slots and COD Upgrades Per Configuration ..... 148

Table 7

Partition Encryption Methods................................................ 181

Table 8

EDLM Policy Settings for Partitions...................................... 219

Table 9

Rackmount Kit Contents ......................................................... 418

Table 10

Rack Ear Kit Contents.............................................................. 421

Table 11

Ethernet Expansion Blade Status LED Descriptions........... 477

Table 12

Blade Status LEDs .................................................................... 502

Table 13

LCB Ethernet Hub Link Activity ........................................... 503

Table 14

Fibre Port Link LED on FC I/O Blade .................................. 504

Table 15

Ethernet Expansion Blade Ethernet Port Link LED States . 504

Table 16

Tape Drive LEDs ...................................................................... 506

Table 17

Fibre Port Link Status .............................................................. 507

xiv

Scalar i500 User’s Guide

Table 18

Power Supply Status ................................................................ 508

Table 19

TapeAlert Flag Severity Codes............................................... 531

Table 20

Tape Drive TapeAlert Flag Descriptions .............................. 532

xv

Figures

Scalar i500 User’s Guide

Figure 1

5U Library Configuration (Standalone Control Module) .... 12

Figure 2

14U Library Configuration (5U Control Module Plus One
9U Expansion Module).............................................................. 13

Figure 3

23U Library Configuration (5U Control Module Plus Two
9U Expansion Modules) ............................................................ 14

Figure 4

Base Systems Plus Expansion Modules .................................. 17

Figure 5

Front Panel Components .......................................................... 18

Figure 6

Back Panel Components............................................................ 21

Figure 7

Power Supply LEDs................................................................... 24

Figure 8

Library Control Blade ................................................................ 26

Figure 9

FC I/O Blade............................................................................... 28

Figure 10

FC I/O Fan Blade ....................................................................... 29

Figure 11

Library Location Coordinates .................................................. 33

Figure 12

Logical Element Addressing, 14U, One Partition, Six Tape
Drives Installed........................................................................... 38

Figure 13

Operator Panel User Interface .................................................. 41

Figure 14

Web Client User Interface ......................................................... 41

Figure 15

LDAP Setup Example .............................................................. 103

xvi

Scalar i500 User’s Guide

Figure 16

Enabling FIPS Mode................................................................. 132

Figure 17

Report Data Buttons................................................................. 142

Figure 18

Saving and E-mailing the Report Data.................................. 143

Figure 19

Forcing Control Path Failover ................................................ 152

Figure 20

Forcing Control Path Failover ................................................ 153

Figure 21

HP LTO-5 Fibre Channel Tape Drive Ports.......................... 156

Figure 22

Enabling Data Path Failover ................................................... 157

Figure 23

Forcing Data Path Failover ..................................................... 158

Figure 24

Forcing Data Path Failover ..................................................... 159

Figure 25

Setup - Encryption System Configuration (KMIP Key
Manager).................................................................................... 171

Figure 26

TLS Communication Certificate Import Screen................... 176

Figure 27

Setup - Encryption Partition Configuration Screen............. 181

Figure 28

Enabling FIPS Mode................................................................. 201

Figure 29

Installing the SNAPI Plug-in .................................................. 210

Figure 30

Installing the SNAPI Plug-in .................................................. 210

Figure 31

StorNext Host Configuration.................................................. 211

Figure 32

Testing the StorNext Settings ................................................. 213

Figure 33

Creating EDLM Partitions....................................................... 214

Figure 34

EDLM Policy Settings for EDLM Library Managed
Partitions.................................................................................... 217

Figure 35

EDLM Policy Settings for Standard Partitions..................... 218

Figure 36

Library Configuration Report................................................. 269

Figure 37

HP LTO-5 Dual Port Fibre Channel Tape Drive.................. 291

Figure 38

HP LTO-5 Single Port SAS Tape Drive ................................. 292

Figure 39

IBM LTO-5 Single Port Fibre Channel Tape Drive.............. 292

Figure 40

Stand-Alone 5U Control Module SCSI Cabling................... 294

Figure 41

Multi-Module SCSI Cabling ................................................... 295

Figure 42

Cabling One or Two Tape Drives Per SCSI Bus .................. 297

Figure 43

Stand-Alone Control Module SAS Cabling .......................... 300
xvii

Scalar i500 User’s Guide

Figure 44

Multi-Module SAS Cabling..................................................... 301

Figure 45

Stand-Alone Control Module Fibre Channel Cabling ........ 304

Figure 46

Multi-Module Fibre Channel Cabling................................... 305

Figure 47

FC I/O Blade ............................................................................. 309

Figure 48

FC With I/O Blade Cabling .................................................... 310

Figure 49

Power Cord Management ....................................................... 319

Figure 50

Ethernet Cable Management .................................................. 322

Figure 51

Cable Management, All Cables, FC I/O Blades Installed .. 323

Figure 52

Cable Management, All Cables, Ethernet Expansion
Blades Installed......................................................................... 324

Figure 53

Cover plate with y-home flag ................................................. 330

Figure 54

Recommended Module Locations ......................................... 331

Figure 55

Y-Rail in Unlocked, Functional Position............................... 335

Figure 56

Cover Plate Location After Adding an Expansion Module348

Figure 57

Library Configuration Example 1 .......................................... 358

Figure 58

Library Configuration Example 2 .......................................... 361

Figure 59

Cover Plate Location After Removing an Expansion
Module ....................................................................................... 370

Figure 60

Scalar i500 Serial Number Label On Control Module Seen
Through Open Front Door387

Figure 61

Scalar i500 SN/WWN Label ................................................... 388

Figure 62

FC I/O Blade and Fan Blade Bays in an Expansion
Module ....................................................................................... 445

Figure 63

Ethernet Connectivity on 5U Libraries.................................. 461

Figure 64

Connecting the Library Control Blade to the Expansion
Module Via Ethernet................................................................ 463

Figure 65

Ethernet Expansion Blade ....................................................... 465

Figure 66

Installing the Ethernet Expansion Blade............................... 467

Figure 67

Ethernet Connectivity on 14U and Higher Libraries .......... 470

Figure 68

Ethernet 27................................................................................. 473

Figure 69

Ethernet Expansion Blade LEDs ............................................ 476

xviii

Scalar i500 User’s Guide

Figure 70

Location of Blade LEDs ........................................................... 501

Figure 71

Location of Tape Drive LEDs ................................................. 505

Figure 72

Barcode Label Orientation ...................................................... 523

xix

Preface

Audience

This guide is intended for anyone interested in learning about or anyone
who needs to know how to install, configure, and operate the
Scalar® i500 library. Be aware that administrator level privileges are
required to configure many of the features described in this guide.

Purpose

This guide contains information and instructions necessary for the
normal operation and management of the Scalar i500 library, including:
• Installing the library
• Basic library operations
• Operator commands
• Troubleshooting

Product Safety Statements

This product is designed for data storage and retrieval using magnetic
tapes. Any other application is not considered the intended use. Quantum
will not be held liable for damage arising from unauthorized use of the
product. The user assumes all risk in this aspect.
This unit is engineered and manufactured to meet all safety and
regulatory requirements. Be aware that improper use may result in bodily
injury, damage to the equipment, or interference with other equipment.

Scalar i500 User’s Guide

1

Preface

Warning:

Scalar i500 User’s Guide

Before operating this product, read all instructions and
warnings in this document and in the System, Safety, and
Regulatory Information Guide. The System, Safety, and
Regulatory Information Guide is located on the Scalar i500
Documentation, Training, and Resource CD.

2

Preface

Mercury Statement

Projectors, LCD displays, and some multifunction printers may
use lamp(s) that contain a small amount of mercury for energyefficient lighting purposes. Mercury lamps in these products
are labeled accordingly. Please manage the lamp according to
local, state, or federal laws. For more information, contact the Electronic
Industries Alliance at www.eiae.org. For lamp-specific disposal
information check www.lamprecycle.org.

Scalar i500 User’s Guide

3

Preface

Disposal of Electrical and
Electronic Equipment

This symbol on the product or on its packaging
indicates that this product should not be disposed
of with your other waste. Instead, it should be
handed over to a designated collection point for
the recycling of electrical and electronic
equipment. The separate collection and recycling
of your waste equipment at the time of disposal
will help to conserve natural resources and ensure
that it is recycled in a manner that protects human
health and the environment. For more information
about where you can drop off your waste
equipment for recycling, please visit our Web site
at: http://www.quantum.com/AboutUs/weee/Index.aspx or contact
your local government authority, your household waste disposal service
or the business from which you purchased the product.

Document Organization

This document is organized as follows:
• Chapter 1, Description, describes basic library configurations and
features.
• Chapter 2, Understanding the User Interface, discusses the operator
panel and the Web client, and the features available on each.
• Chapter 3, Configuring Your Library, explains how to configure your
library for use.
• Chapter 4, Advanced Reporting, describes the features available with
the Advanced Reporting license.
• Chapter 5, Capacity on Demand, describes how to purchase
additional slot capacity for the library.
• Chapter 6, Storage Networking, describes the features available with
the Storage Networking license.
• Chapter 7, Encryption Key Management, describes the features
available with the Encryption Key Management license.
• Chapter 9, Running Your Library, explains how to perform library,
tape drive, and media operations.

Scalar i500 User’s Guide

4

Preface

• Chapter 10, Getting Information – Logs and Reports, explains how to
use the library’s built-in reports to get information you need.
• Chapter 11, Updating Library and Tape Drive Firmware, explains
how to update library and tape drive firmware.
• Chapter 12, Installing, Removing, and Replacing, provides
instructions on how to install, remove, and replace hardware
components in the library, including modules, tape drives, power
supplies, and cables.
• Chapter 13, Troubleshooting, describes the library’s diagnostic
reporting system (RAS tickets) and how to use it. It also describes a
number of diagnostic tests you can run to troubleshoot problems.
• Chapter 14, Working With Cartridges and Barcodes, provides
cartridge handling guidelines.
• Appendix A, Library Specifications, lists the library’s specifications.
• Appendix B, TapeAlert Flag Descriptions, describes of all the
TapeAlerts you may see listed in RAS tickets and reports on your
library.
This document concludes with a glossary.

Notational Conventions

This manual uses the following conventions:
Note:

Note emphasizes important information related to the main
topic.

Caution:

Caution indicates potential hazards to equipment or data.

Warning:

Warning indicates potential hazards to personal safety.

This manual uses the following:
• Right side — Refers to the right side as you face the component being
described.
• Left side — Refers to the left side as you face the component being
described.

Scalar i500 User’s Guide

5

Preface

Related Documents

Documents related to the Scalar i500 are shown below. For the most up to
date product information and documentation, see:
http://www.quantum.com/ServiceandSupport/Index.aspx

Document No.

Document Title

Document Description

6-01741-xx

Scalar i500 Getting
Started Guide

Provides basic cabling and
setup instructions.

6-01317-xx

Quantum Scalar
Intelligent Libraries
SMI-S Reference Guide

Provides an interface
standard that can be used
in a SAN environment.

6-01370-xx

Scalar i500 Tape
Library Basic SNMP
Reference Guide

Describes information you
can obtain from the Scalar
i500 library SNMP.

6-00676-xx

Quantum SNC
Firmware 4 and 5
Reference Guide

Provides information about
the Storage Network
Controller, an optional
component that provides
Fibre-Channel to FibreChannel connectivity.

6-01385-xx

Scalar i500 Unpacking
Instructions (5U)

Unpacking instructions.

6-01524-xx

Scalar i500 Unpacking
Instructions (9U)

Unpacking instructions.

6-01525-xx

Scalar i500 Unpacking
Instructions (14U)

Unpacking instructions.

6-01378-xx

Scalar i500 Release
Notes

Describes changes to your
system or firmware since
the last release, provides
compatibility information,
and discusses any known
issues and workarounds.

Refer to the appropriate product manuals for information about your
tape drive and cartridges.

Scalar i500 User’s Guide

6

Preface

SCSI-2 Specification

0

The SCSI-2 communications specification is the proposed American
National Standard for information systems, dated March 9, 1990. Copies
may be obtained from:
Global Engineering Documents
15 Inverness Way, East
Englewood, CO 80112
(800) 854-7179 or (303) 397-2740

Contacts

Quantum company contacts are listed below.
Quantum Corporate Headquarters

0

For information about contacting Quantum, including Quantum office
locations, go to:
http://www.quantum.com/aboutus/contactus/index.aspx
Quantum Home Page

0

Visit the Quantum home page at:
http://www.quantum.com

Scalar i500 User’s Guide

7

Preface

Getting More Information or
Help

StorageCare™, Quantum’s comprehensive service approach, leverages
advanced data access and diagnostics technologies with crossenvironment, multi-vendor expertise to resolve backup issues faster and
at lower cost.
Accelerate service issue resolution with these exclusive Quantum
StorageCare services:
• Service and Support Web site — Register products, license software,
browse Quantum Learning courses, check backup software and
operating system support, and locate manuals, FAQs, firmware
downloads, product updates and more in one convenient location.
Benefit today at:
http://www.quantum.com/ServiceandSupport/Index.aspx.
• eSupport — Submit online service requests, update contact
information, add attachments, and receive status updates via e-mail.
Online Service accounts are free from Quantum. That account can
also be used to access Quantum’s Knowledge, a comprehensive
repository of product support information. Sign up today at:
http://www.quantum.com/osr
• StorageCare Guardian — Securely links Quantum hardware and the
diagnostic data from the surrounding storage ecosystem to
Quantum’s Global Services Team for faster, more precise root cause
diagnosis. StorageCare Guardian is simple to set up through the
internet and provides secure, two-way communications with
Quantum’s Secure Service Center. More StorageCare Guardian
information can be found at:
http://www.quantum.com/ServiceandSupport/Services/Guardian
Information/Index.aspx.
• Quantum Vision™ — Quantum Vision management software
provides industry-leading administration and helps users make
informed decisions about their growing backup needs. Vision™
software saves users time and increases data security by giving users
centralized, global monitoring and reporting for their for all their
Quantum DXi Series disk systems and Quantum tape libraries. More
StorageCare Vision information can be found at:
http://www.quantum.com/products/Software/quantumvision/In
dex.aspx

Scalar i500 User’s Guide

8

Preface

For further assistance, or if training is desired, contact Quantum
Customer Support Center:
United States

800-284-5101 (toll free)
949-725-2100

EMEA

00800-4-782-6886 (toll free)
+49 6131 3241 1164

APAC

+800 7826 8887 (toll free)
+603 7953 3010

For worldwide support:
http://www.quantum.com/ServiceandSupport/Index.aspx

Scalar i500 User’s Guide

9

Chapter 1

1

Description

The Scalar i500 tape library automates the retrieval, storage, and
management of tape cartridges. Tape cartridges are stored in the library
and mounted and dismounted from tape drives using firmware running
on the library or software running on the host systems.
The Scalar i500 tape library offers advanced management features and
reliability as well as scalable performance and storage capacity. As your
storage capacity and tape drive requirements change, expansion modules
can be added to the library, allowing a configuration of up to a full 41
rack units (41U, where 1U = 1.75”).
This chapter covers:
• Intelligent Storage
• Library Configuration
• Modules
• Front Panel Components
• Back Panel Components
• Robotic System and Barcode Scanner
• Tape Drive Support
• Library Features
• Understanding the Location Coordinates
• Understanding Logical Element Addressing

Scalar i500 User’s Guide

10

Chapter 1 Description
Intelligent Storage

Intelligent Storage
The Scalar i500 is the intelligent library platform that gives growing
midrange storage environments faster, easier, and more reliable data
protection. The Scalar i500 combines modular design with continuous
robotics to provide industry-leading scalability, performance, and
reliability. Designed with Quantum’s iPlatform architecture and iLayer
management approach, the Scalar i500 makes backup easier to manage.
Its proactive monitoring and remote diagnostics can reduce service calls
by 50% and shorten issue resolution times by 30%. Its Capacity on
Demand (COD) scalability lets it grow non-disruptively with users’ data.
And the Scalar i500 is designed to integrate easily with disk backup,
making it the perfect library for next-generation backup architectures.
With the Scalar i500, Information Technology managers can be assured
they will have reliable, high-performance backup, certain restores, and
effective long-term protection for years into the future, no matter how
their storage needs evolve.

Library Configuration
The Scalar i500 library is designed for ease of installation, configuration,
and field upgrades. The Scalar i500 library is built upon two basic
building blocks: the 5U control module and 9U expansion module.
These building blocks form the basis of the following library
configurations:
• A 5U library, consisting of a 5U stand-alone control module. Figure 1
shows the front view of a 5U library.
• A 14U library, consisting of one 5U control module and one 9U
expansion module. Figure 2 on page 13 shows the front view of a 14U
library.
• A 23U library, consisting of one 5U control module and two 9U
expansion modules. Figure 3 on page 14 shows the front view of a
23U library.

Scalar i500 User’s Guide

11

Chapter 1 Description
Library Configuration

The 5U, 14U, and 23U libraries are the base Scalar i500 systems. By
adding 9U expansion modules, you can upgrade a base system to:
• A 32U library, consisting of one 5U control module and three 9U
expansion modules
• A 41U library, consisting of one 5U control module and four 9U
expansion modules

Figure 1 5U Library
Configuration (Standalone
Control Module)

Scalar i500 User’s Guide

1

12

Chapter 1 Description
Library Configuration

Figure 2 14U Library
Configuration (5U Control
Module Plus One 9U
Expansion Module)

Scalar i500 User’s Guide

1

Control module

2

Expansion module

13

Chapter 1 Description
Library Configuration

Figure 3 23U Library
Configuration (5U Control
Module Plus Two 9U
Expansion Modules)

Scalar i500 User’s Guide

1

5U control module

2

9U expansion module

3

9U expansion module

14

Chapter 1 Description
Modules

Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a crosssectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, allow 60 cm (24
inches) in the front and back of the library.

Modules
Scalar i500 libraries are modular, and you can increase the size at any
time. The three base systems for the Scalar i500 library are as follows:
• The 5U library, consisting of a control module
• The 14U library, consisting of a 5U control module and a 9U
expansion module
• The 23U library, consisting of a 5U control module and two 9U
expansion modules
These configurations can be scaled up by adding 9U expansion modules
to a maximum rack height of 41U. Expansion modules provide additional
capacity as your storage and tape drive requirements change. See Figure
4 on page 17 for an illustration of library scalability. For information on
installing, removing, and replacing modules, see Installing, Removing,
and Replacing on page 286.
Each module has a specific number of fixed storage slots, I/E station
slots, and tape drive slots available. See Library capacity is as follows. on
page 526 for the number of slots available for each library configurations.
Note:

Scalar i500 User’s Guide

Slot counts in this document do not include five inaccessible
slots in the bottom row of any library configuration. For more
information about these slots, see Unused Slots on page 247.
15

Chapter 1 Description
Modules

Control Module

1

The control module is required in any Scalar i500 library configuration.
The control module contains the robotic controls, library control blade
(LCB), and touch screen display. The control module also contains an
import/export (I/E) station, fixed storage slots, tape drives, and at least
one power supply.

Expansion Modules

1

Expansion modules are supplementary modules that can be stacked
above or below the control module. Each expansion module contains
fixed storage slots, tape drive slots, and power supply slots.The I/E
stations on expansion modules are included and may be configured as
storage. Expansion modules also contain bays for optional Fibre Channel
(FC) Input/Output (I/O) blades, which provide FC connections for FC
drives in the library.
If an expansion module is used only for storage and does not contain tape
drives or FC I/O blades, it does not need a separate power supply. All
power is derived from the control module.

Stackability

Scalar i500 User’s Guide

1

The maximum rack height of the library is 41U, which consists of a 5U
control module and four 9U expansion modules. Figure 4 illustrates the
stackability of the library and the recommended library configurations.

16

Chapter 1 Description
Modules

Figure 4 Base Systems Plus
Expansion Modules

5U
(41 slots)

14U
(133 slots)

23U
(225 slots)

32U
(317 slots)

41U
(409 slots)

9U Expansion
Module

5U Control
Module

Scalar i500 User’s Guide

5U Control
Module

5U Control
Module

5U Control
Module

9U Expansion
Module

9U Expansion
Module

5U Control
Module

9U Expansion
Module

9U Expansion
Module

9U Expansion
Module

9U Expansion
Module

9U Expansion
Module

9U Expansion
Module

9U Expansion
Module

17

Chapter 1 Description
Front Panel Components

Front Panel Components
Figure 5 shows the front panel components of the library. The paragraphs
following Figure 5 describe the components in detail.

Figure 5 Front Panel
Components

Access Door
Scalar i500 User’s Guide

1

1

Access door

2

Operator panel

3

I/E station

4

Front power button

The access door allows access to the internal components of the library.
Each control module and expansion module has an access door. In most
18

Chapter 1 Description
Front Panel Components

cases, you will not need to access the library through this door except
when you want to bulk load or unload cartridges from the library.
The access door is locked by the I/E station door. To open the access
door, you must first open the I/E station door. If you want to prohibit
access to the library, which is recommended for security reasons, lock the
I/E station door. This keeps unauthorized users from accessing tape
cartridges.
You can lock and unlock the I/E station door using commands on the
Operations menu. For more information, see Locking and Unlocking the
I/E Stations on page 262.
If the access door is opened, the library is not available for use. When an
access door (on any module) is opened, all in-progress motion commands
are stopped, and the picker slowly lowers to the bottom of the library.
When the access door is closed, the library returns any media in the
picker to its original slot and also performs a library inventory.

Caution:

I/E Station

1

Care should be taken to avoid opening the access door
during robotic operations since the robot will stop
immediately and will fail to complete the current
operation.

I/E stations enable importing and exporting cartridges with minimal
interruption of normal library operations. I/E stations are located on the
front of the control module and on the front of expansion modules. A 5U
I/E station has a capacity of six cartridges within a removable magazine.
A 9U I/E station has a capacity of 12 cartridges within two removable
magazines.
The I/E stations can also be configured as storage as well as become part
of a logical division of library resources known as a partition. The I/E
station is shared among all partitions, but the I/E station slots are owned
by one partition at a time. When an I/E station slot is assigned to a
partition, only the assigned partition can access that slot.

Operator Panel

Scalar i500 User’s Guide

1

The operator panel is the touch screen display device upon which the
graphical user interface (GUI) appears. The operator panel is located on
the access door of the control module. The library operations and service
functions are performed from this screen. The GUI is also accessible

19

Chapter 1 Description
Back Panel Components

through a remote Web client. For more information on the library user
interfaces, see Chapter 2, Understanding the User Interface.

Front Power Button

1

Turning off the front power button turns off the robot and operator panel,
but power still runs to the power supplies. Use the front power button to
manually shut down the library. See Shutting Down, Powering Off, and
Completely Removing Power on page 238 for instructions on how to shut
down or restart the library safely.

Back Panel Components
Figure 6 shows the back panel components of the library. The paragraphs
following Figure 6 describe the components in detail.

Scalar i500 User’s Guide

20

Chapter 1 Description
Back Panel Components

Figure 6 Back Panel
Components

Rear Power Switches

Scalar i500 User’s Guide

1

1

Library control blade (LCB)

2

FC I/O blade (optional)

3

FC I/O fan blades (required with FC I/O blades)

4

Rear power switch

5

Power supplies

6

Upper and lower Ethernet ports on expansion
module

7

Module terminator connectors

Rear power switches are located on each power supply. Turning off the
rear power switch on a power supply removes all power from the library.

21

Chapter 1 Description
Back Panel Components

The rear power switches should be used in all emergency and service
situations.

Power System

1

Warning:

Turn off the rear power switch whenever you are servicing
the library. In the event of danger to personnel or
property, immediately turn off the rear power switch and
remove all power cords.

Caution:

Except in emergencies, use the shutdown procedure
before switching off the rear power switch. See Shutting
Down, Powering Off, and Completely Removing Power
on page 238 for instructions on how to shut down the
library.

The library supports single and redundant power configurations. The
single power configuration has a single AC line input and single DC
power supply. The redundant configuration has dual AC line input and
dual DC power supplies.
If you have redundant power supplies, you can “hot swap” a power
supply (power to the library remains on while you exchange the
hardware), and you can “hot add” power supplies to other modules
(power to the library remains on while you are adding the hardware).

Scalar i500 User’s Guide

Caution:

At least one power supply must be plugged in at all times.

Warning:

The power outlet must be available near the library and
must be easily accessible.

Caution:

The control module and each expansion module that
contains drives must have at least one power supply for
every four drives. You can add a redundant power supply
to each module. Installing one power supply in one
module and another power supply in another module
does not provide redundant power; the two power
supplies must reside in the same module.

22

Chapter 1 Description
Back Panel Components

The power system consists of the following components:
• Power supply
• AC power cord
The power supply has three light-emitting diodes (LEDs) that provide
status information. These LED status indicators are green and blue in
color.
• Green represents AC OK or DC OK.
• Blue represents swap-mode power status.
Figure 7 shows the power supply LEDs. For more information on the
behavior of the LEDs, see Power Supply LEDs on page 508.

Scalar i500 User’s Guide

23

Chapter 1 Description
Back Panel Components

Figure 7 Power Supply LEDs

1

Library Control Blade

1

LEDs

The library control blade (LCB) manages the entire library, including the
operator panel and picker assembly, and is responsible for running
system tests to ensure that the library is functioning properly. The LCB
also provides internal communication to Fibre Channel (FC) I/O blade
slots. The LCB has four Ethernet ports, supporting a total of four FC I/O
blades in the library.
The LCB indicates its status with three LED Reliability, Availability, and
Serviceability (RAS) status indicators. These indicators are green, amber,
and blue in color.

Scalar i500 User’s Guide

24

Chapter 1 Description
Back Panel Components

• Green represents processor status.
• Amber represents health status.
• Blue represents power-control status.
Figure 8 shows the location of the LCB components, including LEDs. For
more information on the behavior of the LCB LEDs, see Blade Port LEDs
on page 503.

Scalar i500 User’s Guide

25

Chapter 1 Description
Back Panel Components

Figure 8 Library Control Blade

Fibre-Channel
Input/Output Blades

Scalar i500 User’s Guide

1

1

LEDs (blue, amber, green)

2

Gigabit Ethernet (external network) port

3

Ethernet I/O blade control ports (inactive if FC I/O
blades are not installed)

4

Service Ethernet port

5

Service serial port

Expansion modules support optional Fibre Channel (FC) Input/Output
(I/O) blades that provide connections for FC tape drives in the library.
Each FC I/O blade has an embedded controller that provides
connectivity and features that enhance the performance and reliability of
tape drive operations. I/O blades also aggregate FC tape drive
connections, reducing switch port and cabling requirements.

26

Chapter 1 Description
Back Panel Components

Each FC I/O blade has six auto-negotiating, 4 Gb/s FC ports and
backplane connections. The FC I/O blade provides two host
communication ports and four connection ports to FC drives. Each FC
I/O blade is cooled by a fan blade that is installed next to the FC I/O
blade in the expansion module. FC I/O blades and fan blades are hotswappable.
FC I/O blades cannot be installed in the control module, so your library
configuration must include at least one expansion module to include FC
I/O blades. Each expansion module can house up to two FC I/O blades.
Depending on the number of installed expansion modules, the library can
support from one to four FC I/O blades. No library configuration can
contain more than four FC I/O blades. Any FC drive in the library,
including drives in the control module, can be connected to an FC I/O
blade in an expansion module.
Note:

FC I/O menu commands are available for use only when FC
I/O blades are installed in the library.

The FC I/O blade indicates its status with three LED status indicators.
These indicators are green, amber, and blue in color.
• Green represents processor status.
• Amber represents health status.
• Blue represents power-control status.
Figure 9 shows the FC I/O Blade, including LEDs. For more information
on the behavior of the FC I/O Blade LEDs, see Blade Status LEDs on
page 500.
For information on configuring I/O blades, see Working With FC I/O
Blades on page 109.
For information on installing and cabling FC I/O blades and FC tape
drives, see Chapter 12, Installing, Removing, and Replacing.

Scalar i500 User’s Guide

27

Chapter 1 Description
Back Panel Components

Figure 9 FC I/O Blade

1

FC ports to host(s)

2

FC ports to drive(s)

3

LEDs (blue, amber, green)

Each FC I/O blade is cooled by a fan blade that is installed next to the FC
I/O blade in the expansion module. For information on installing the fan
blade, see Adding, Removing, and Replacing the FC I/O Fan Blade on
page 454.
Figure 10 shows the FC I/O fan blade, including the LED. The single
amber LED represents health status. For more information on the
behavior of the FC I/O fan blade LED, see Tape Drive LEDs on page 505.

Scalar i500 User’s Guide

28

Chapter 1 Description
Robotic System and Barcode Scanner

Figure 10 FC I/O Fan Blade

1

LED (amber)

Robotic System and Barcode Scanner
The robotic system identifies and moves the cartridges between the
storage slots, tape drives, and the I/E station. The robotic arm (picker)
has picker fingers that enable it to grab tape cartridges and move them
into positions along X, Y, and Z motion coordinates. The robotic system
and the barcode scanner work together to identify the locations of
resources within the library.
Each tape cartridge must contain a barcode that the barcode scanner
reads during the inventory process. During the inventory process, the
Scalar i500 User’s Guide

29

Chapter 1 Description
Tape Drive Support

barcode scanner reads the fiducial labels to identify the types of
magazines and tape drives that are installed in the library.
Every tape cartridge must have a unique machine-readable barcode
attached to it. Tape cartridges cannot have duplicate barcode labels. This
barcode identifies the cartridge. The library stores the physical location of
the tape cartridge in an inventory database. All library or host requests
typically reference the location of the tape cartridges based on this
barcode number. Barcode labels are mandatory and must adhere to
specific standards. For more information on barcodes, see Chapter 14,
Working With Cartridges and Barcodes.

Tape Drive Support
Details about tape drive support include:
• Every library configuration must contain at least one tape drive.
• Control modules can hold a maximum of two tape drives.
• Expansion modules can hold a maximum of four tape drives.
Please see Supported Components on page 524 for a list of tape drives
and media supported by the Scalar i500 library.
The library supports mixing different tape drive types within the library
and within partitions. For information on how to do this, see Working
With Partitions on page 68.
SCSI and SAS tape drives are attached directly to the host. FC tape drives
can be directly attached to hosts or to the Storage Area Network (SAN).
FC tape drives can also be attached to FC I/O blades, which manage
communication between the hosts and the drives. For more information
on FC I/O blades, see Working With FC I/O Blades on page 109. HP
LTO-5 Fibre Channel tape drives can use the library’s Storage
Networking features (see Chapter 6, Storage Networking).
Tape drives are installed into tape drive slots in the rear of the library. If a
tape drive slot is empty, a filler plate covers the empty tape drive slots to
prevent debris from entering the library. Tape drives are shipped filling

Scalar i500 User’s Guide

30

Chapter 1 Description
Library Features

the tape drive slots from the bottom to the top of the library, but the tape
drives can be reinstalled in any available tape drive slot.
Note:

Tape drive filler plates must be in place for the library to
operate at normal speed.

For information on adding tape drives, see Adding a Tape Drive on
page 438.

Library Features
This section describes several features of Scalar i500 libraries.

User Interface

1

The operator panel is located on the front door of the control module and
allows you to work locally on the library via the user interface. The Web
client allows you to view and perform library functions from remote sites
and is accessible through a browser. The operator panel and Web client
contain a similar user interface and functionality.
See Chapter 2, Understanding the User Interface for more information
about the operator panel and the Web client.

Partitions

1

Partitions are virtual sections within a library that present the appearance
of multiple, separate libraries for purposes of file management, access by
multiple users, or dedication to one or more host applications.
Organizing the library into partitions divides the resources into virtual
sections. Partitions can be used to control access to portions of the library
by granting permissions to user accounts to access certain partitions.
For more information on partitions, see Working With Partitions on
page 68.

Scalar i500 User’s Guide

31

Chapter 1 Description
Licensable Features

Control Path Modification 1

Support for WORM

1

The control path tape drive is used to connect a partition to a host
application. Only one tape drive can be selected as the control path at one
time. For more information, see Working With Control Paths on page 86.

Scalar i500 tape libraries support WORM (write once, read many)
technology in LTO-3, LTO-4, LTO-5 and LTO-6 tape drives. WORM
allows non-rewriteable and non-erasable data to be written and provides
extra data security by prohibiting accidental data erasure. The WORM
feature is supported whenever you use WORM cartridges.

Licensable Features
In addition to the standard features, the following additional, licensable
features are available for the Scalar i500:
• Advanced Reporting, described in Chapter 4, Advanced Reporting
• Capacity on Demand, described in Chapter 5, Capacity on Demand
• Storage Networking, described in Chapter 6, Storage Networking
• Encryption Key Management, described in Chapter 7, Encryption
Key Management
If you purchase these features with your library, the license will be
installed when you receive the library. If you upgrade or add new
features after the initial purchase, you will need to obtain and install a
license key. For information on how to obtain and install a license key, see
Obtaining and Installing a License Key on page 88.

Understanding the Location Coordinates
This section describes the numbering system the library uses to identify
components of the library. The library location coordinates contain the
following digits: [Module],[Column],[Slot]. Figure 11 shows how a
Scalar i500 User’s Guide

32

Chapter 1 Description
Understanding the Location Coordinates

library with a control module and an expansion is numbered.
Note:

The library location coordinates are different from the logical
element addressing; see Understanding Logical Element
Addressing on page 35 for more information.)

Figure 11 Library Location
Coordinates

Scalar i500 User’s Guide

33

Chapter 1 Description
Understanding the Location Coordinates

Modules

1

Library modules are represented by the first digit of a library coordinate.
Modules are identified relative to the control module.
The control module is numbered 0 (zero). Expansion modules stacked
above the control module are addressed with positive integer digits
depending on their position above the control module. For example, the
expansion module stacked directly above the control module is number
1. The expansion module stacked directly above module 1 is number 2,
and so on.
Modules stacked below the control module are numbered with negative
integer digits, also depending on their relative position to the control
module. For example, the expansion module stacked directly below the
control module is number –1. The expansion module stacked directly
below module –1 is number –2, and so on.

Columns

1

A storage column is a group of slots arranged vertically in the library.
Columns are represented by the second digit of a library coordinate.
Columns are identified relative to the front left of the library. The column
in the front left of the library is number 1. The column numbering
continues around the library in a clockwise direction. The I/E station
column is always number 6.

Slots

1

Fixed storage slots are represented by the third digit of the library
location coordinate. Within each column, slots are numbered from top to
bottom, starting at 1. For example, in Figure 11 on page 33, the full
location coordinate of Slot 1 is 0, 1, 1.

Tape Drives

1

Tape drives are addressed first by module and then by tape drive bay
within the module. The drive bays within a module are numbered from
top to bottom. A one-based numbering system is used. The full address of
a tape drive is in the form of [module,drive bay]; for example: [0,1], [1,3],
[-1,2].

Fibre Channel I/O Blades 1

Scalar i500 User’s Guide

Fibre Channel (FC) I/O blades are addressed first by module and then by
FC I/O blade bay within the expansion module. The blade bays within a
module are numbered from top to bottom. A one-based numbering
system is used. The full address of a an FC I/O blade bay is in the form of
[module,FC I/O blade bay]; for example: [1,1], [-1,2].

34

Chapter 1 Description
Understanding Logical Element Addressing

Ethernet Expansion
Blades

1

Power Supplies

1

Ethernet Expansion Blades (EEBs) are addressed first by module and then
by EEB bay within the expansion module9U Library Expansion Module.
The blade bays within a module are numbered from top to bottom. The
blade bay is always on the bottom of the unit. A one-based numbering
system is used. The full address of a an EEB blade bay is in the form of
[module,EEB]; for example: [1,2], [-1,2].

Power supplies are addressed as [module,PS#], where PS# is 1 for the left
power supply and 2 for the right power supply. The PS# is also etched on
the module chassis, above each power supply.

Understanding Logical Element Addressing
The library uses standard industry conventions to logically number every
storage slot, I/E station slot, and tape drive in the library. Host software
is designed to understand this addressing system, and generally there are
no problems relating to tape cartridge slots. However, hosts sometimes
have problems relating to tape drives, particularly when tape drives,
library control modules, or library expansion modules are added or
removed, or empty tape drive slots exist. This section explains how the
library logically addresses tape drives and slots, so that you can avoid
common problems with host software.
Note:

Tape Drive Logical
Element Addressing

Scalar i500 User’s Guide

1

The logical element addressing described in this section is
different from the library-specific location coordinates
described in Understanding the Location Coordinates on
page 32.)

Tape drive logical element addresses are assigned by partition. The
numbering is sequential within a partition and starts over with each
partition. The addresses start with the lowest library module in a
partition. The top tape drive in the module and partition is always
number 256. The tape drive beneath that is 257, and so on until all tape
drives in that module/partition have been accounted for. Numbering

35

Chapter 1 Description
Understanding Logical Element Addressing

continues with the top tape drive in the next module up. Empty tape
drive slots are skipped (they are not given an element address).
Host software may have problems recognizing tape drives when tape
drives, control modules, or expansion modules are added, removed, or
replaced; or when partitions are added, deleted, or modified, because
existing logical element addresses can change. Therefore, after making
any of these types of modifications, you must refresh the configuration of
any backup application that manages the library to reflect new tape drive
positions. In addition, you may need to reboot the host server(s) or rescan
the bus to detect the changes.
See Figure 12 on page 38 for a simple example of element addressing in a
14U library with a single partition, six tape drives installed and no empty
tape drive slots. Note that multiple partition can create complexity. If you
need help with the element addressing in your library, contact Quantum
Support.

Cartridge Slot Logical
Element Addressing

1

Tape cartridge slots are assigned logical element addresses by partition.

The numbering is sequential within a partition and starts over with each
partition. Numbering begins at the top left slot (as you look at the library
from the front) in the lowest module in the library and moves
sequentially down the left-most column. The top left slot of every
partition is always number 4096, the slot beneath that is 4097, and so on.
When the numbering reaches the bottom of the column, it continues to
the top slot in the next column to the right (as long as it is in the same
module and partition) and moves down that column. When all of the
slots in the lowest module belonging to a partition have been accounted
for, numbering continues to the top left slot in the next module above (as
long as it is in the same partition). The numbering can get tricky when
partitions span modules and do not use all of the slots in a module.
Tape cartridge slots are assigned a logical element address whether they
contain a cartridge or not. Cartridges themselves are not given a logical
element address; only the slot is. Slot element addresses change when
slots are added or removed; partitions are added, removed, or modified;
or cleaning slots are added or removed.

I/E station slots are numbered differently from partitions. Numbering
begins at the top I/E station slot in the uppermost module that contains
I/E station slots, and continues sequentially downward. This top slot has
element address 16. The slot beneath that is 17, and so on.

Scalar i500 User’s Guide

36

Chapter 1 Description
Understanding Logical Element Addressing

Cleaning slots belong to the System partition and are not reported to the
host. Cleaning slots are skipped (they are not given a logical element
address), so adding or removing a cleaning slot will renumber all of the
slots in a partition.

Generally, host software easily recognizes logical slot element addresses,
even when they change. The next time the host issues a READ ELEMENT
STATUS command, it will process the new number and recalculate all of
the slot addresses.
See Figure 12 on page 38 for a simple example of element addressing in a
14U library with a single partition.

Scalar i500 User’s Guide

37

Chapter 1 Description
Understanding Logical Element Addressing

Figure 12 Logical Element
Addressing, 14U, One Partition,
Six Tape Drives Installed

Note: Empty drive bay
element addresses are
skipped. This picture
assumes six tape drives are
installed.

Tape cartridge slots in partition
I/E station slots
Tape drives
Unused slots

Scalar i500 User’s Guide

38

Chapter 2

Understanding the User Interface

2

The user interface of Scalar i500 libraries is available in two formats: the
operator panel and the Web client. Operations on the library can be
performed locally on the control module using the operator panel or
remotely on your computer using the Web client. Similar functionality
with common elements is used for both formats.
Both the Web client and operator panel user interfaces are required to
operate the library. Some functionality is only available through the Web
client, and some functionality is only available through the operator
panel. However, using the Web client rather than the operator panel to
perform library operations (when possible) is recommended.
Caution:

Do not perform inventory operations (for example,
working with RAS tickets, creating/modifying/deleting
partitions) while the library is performing an inventory.
Doing so may result in inventory discrepancies, such as
missing tape cartridges.

This chapter covers:
• Common User Interface Elements
• Operator Panel
• Web Client
• Menu Trees

Scalar i500 User’s Guide

39

Chapter 2 Understanding the User Interface
Common User Interface Elements

• User Privileges
• User Access

Common User Interface Elements
The user interface consists of the following areas:
• Header — appears on every screen and contains the company logo,
product name, and the three main navigation buttons. The main
navigation buttons are:
•

Home — Home page.

•

Help — Context-sensitive Help for the active screen.

•

Logout — Ability to log out.

• Title Bar/Menu Tabs (operator panel)— This area appears below the

header. On the home page, it provides the library/partition name
and access to the menu tabs on the main screen. On all other screens,
this area is a single bar and provides the screen name.

• Menu Bar (Web client)— Lists the menu choices.
• Main — Main content area of the screen.
• Health/Navigation — provides information about the “health” of the
library by means of three subsystem status buttons: Library, Drives,
and Media. See System Summary and Subsystem Status on page 42
for more information on the subsystem buttons.
Note:

A message in the header alerts you when the robot is not ready
to perform library functions. See Troubleshooting “Library
Not Ready” Messages on page 490 for more information on
“Library Not Ready” messages displayed in the header.

Figure 13 and Figure 14 show the operator panel and the Web client
interfaces.

Scalar i500 User’s Guide

40

Chapter 2 Understanding the User Interface
Common User Interface Elements

Figure 13 Operator Panel User
Interface

Figure 14 Web Client User
Interface

Scalar i500 User’s Guide

41

Chapter 2 Understanding the User Interface
Common User Interface Elements

System Summary and
Subsystem Status

2

You can quickly gauge the health of the library by observing the color of
the three subsystem status buttons located at the bottom of the home
page. These buttons provide quick access to information about the
“health” of the library for faster recovery if problems occur. You can
select the buttons to view Reliability, Availability, and Serviceability
(RAS) tickets that report problems in the subsystems.
The three subsystems are:
• Library — This subsystem represents connectivity, control, cooling,
power, and robotics.
• Drives — This subsystem represents tape drive components, such as
tape drives, tape drive firmware, and tape drive sleds.
• Media — This subsystem represents media components, such as
cartridges and barcode labels.
Each subsystem button will be in one of three states indicated by color.
The three states are:
• Green — No RAS tickets exist for this subsystem, or, if any tickets do
exist, they have all been closed.
• Yellow — The library contains open or unopened, low- or highpriority RAS tickets for this subsystem.
• Red — The library contains open or unopened urgent RAS tickets for
this subsystem.
If the color of a subsystem button is red or yellow, you can click the
button to display the corresponding RAS Tickets screen. This screen lists
library, drives, or media RAS tickets, depending on which button was
selected. RAS tickets display in order of last occurrence of each event,
starting with the most recent.
Note:

Last Occurrence indicates the last time a ticket event occurred.
This information updates any time the event recurs. Last
Occurrence does NOT update if you open, close, or resolve the

RAS Ticket.

You can change the order in which the RAS tickets are displayed by
clicking any header item (for example, Priority, Last Occurrence, or
Name).

Scalar i500 User’s Guide

42

Chapter 2 Understanding the User Interface
Operator Panel

On the Web client, you can view closed tickets by selecting the Include
Closed Tickets check box.
You can also open the All RAS Tickets screen by selecting Tools > All RAS
Tickets. See About RAS Tickets on page 481 for more information about

RAS tickets.

Home Page

2

The home page is common to both the operator panel and the Web client.
The home page provides tabular data on the capacity of the library’s
partitions, slots, and drives. You can use the home page to see a quick
summary of the capacity of the library. You can also see which partitions
are online (in the Storage Slots section). The current user’s login
privileges determine the information that is displayed on the home page.
Details about the home page include:
• On the Web client, users see the partitions (in alphabetical order) to
which they have access.
• On the operator panel, if users have access to more than one partition,
they can navigate to other partitions using the arrows next to the
partition name in the title bar at the top of the screen.
For more information about user privileges, see User Privileges on
page 50 and Working With User Accounts on page 97.

Operator Panel
The operator panel is physically attached to the front door of the control
module. The user interface appears on the touch-screen LCD display of
the operator panel for executing basic library management functions.
Audible feedback, or “key click” sounds, are generated when a user
presses a button on the operator panel. Users can choose to disable the
audible feedback. See Configuring System Settings on page 126.

Scalar i500 User’s Guide

43

Chapter 2 Understanding the User Interface
Web Client

Operator Panel Keypads 2

When a user touches a text box requiring data entry, a keypad screen
appears. The alpha, numeric, or month keypad appears, depending on
the type of input field touched. All alphabetic character entries are lower
case. The text box appears at the top of screen, and the
numbers/characters appear as they are entered. Pressing 123 opens the
numeric keypad.

Operator Panel Indicates
Intervention Required 2

The operator panel lights up (screen saver turns off) if intervention is
required. For example, when manual cartridge assignment is enabled, the
operator panel lights up following an import of tapes into the I/E station
so that the operator sees the prompt to assign tapes to a partition.

Web Client
The Web client user interface is similar to the operator panel user
interface. The Web client interface is accessible from supported Web
browsers. See Library Capacity on page 526 for information about
supported browsers.
To manage the library from a remote location, you must set up the
library’s initial network configuration from the operator panel touch
screen. See Configuring Library Security Settings on page 124 for
information on setting the network configuration settings for remote use.
You must disable Web browser popup blockers to use the Web client
interface and the library’s online Help. Add the Scalar i500’s Internet
Protocol (IP) address to the list of trusted/allowed sites on your Scalar
i500-supported browser, so the Web client pages will automatically
refresh.

Scalar i500 User’s Guide

Note:

Do not use your Internet browser Back button to navigate the
Web client pages. Instead, use the buttons provided within the
Web client.

Note:

Log out of the library before closing the Internet browser
window when you are using the Web client. If you do not log
out, the session will remain open.
44

Chapter 2 Understanding the User Interface
Menu Trees

Menu Trees
The following menus organize operations and commands into logical
groupings:
• The Setup menu consists of commands that administrators can use to
set up and configure various aspects of the library, including
partitions, I/E station slots, cleaning slots, control paths, network
settings, drive settings, users, notifications, date and time, licenses,
FC I/O blades, library registration, and e-mail.
• The Operations menu consists of commands that enable users to
change the library’s mode of operations, import and export
cartridges, load and unload tape drives, move media, perform
diagnostics, and log off. Administrators can also access commands to
lock or unlock the I/E station and to shut the library down.
• The Tools menu consists of commands that you can use to maintain
your library, such as viewing RAS Tickets, generating diagnostic
logs, identifying drives, configuring the internal network, saving and
restoring the library configuration, setting system and security
settings, and updating firmware.
• The Reports menu (Web client only) consists of summaries of library
information.
A hidden Service menu is available to service users with the appropriate
login information.
The menus vary somewhat between the Web client and operator panel
user interfaces. Administrators have access to all menu commands; users
with user privileges have more limited access.
Table 1 lists the Web client menus. Some menu commands are available
only to administrators.
I/O blade menu items are available for libraries that contain I/O blades.

Scalar i500 User’s Guide

45

Chapter 2 Understanding the User Interface
Menu Trees

Table 1 Web Client Menus

Setup Menu*

Operations Menu

Tools Menu*

Reports Menu

• Setup Wizard

• Media

• All RAS Tickets

• System Information

• Partitions

• Move

• Capture Snapshot

• Library Configuration

• Host Access

• Import

• Save/Restore
Configuration

• Network Settings

• Host Registration
• Host Connections

• Export
• Cleaning Media

• Cleaning Slots

• Import

• I/E Station Slots

• Export

• Drive Settings
• Control Path
• License
• Notifications

• Partitions
• Change Mode
• Drive
• Load

• E-mail Configuration

• Unload

• Advanced Reporting
(if licensed)

• Change Mode

• Receiver
Addresses
• Media Security
• RAS

• I/E Station
Lock/Unlock*
• System Shutdown*
• Logout

• E-mail
Configuration
Record
• Save Configuration
Record
• Identify Drives
• Drive Operations
• Download SNMP
MIB

Scalar i500 User’s Guide

• Drive Resource
Utilization
• Media Integrity
Analysis
• About

• Import
Communication
Certificates

• Import

• SNMP Trap
Registrations

• Advanced Reporting*

• EKM Management

• Contact
Information

• SNMP

• Log Viewer*

• FC I/O Blade Port
Info**

• Encryption
Certificate

• Network

• All Slots

• FC I/O Blade Info**

• Receiver
Addresses

• Network Management

• Logged In Users*

• Export
• Encryption Key
• Import
• Export
• Retrieve SKM Logs
(if SKM enabled)

46

Chapter 2 Understanding the User Interface
Menu Trees

Setup Menu*
• User Management
• User Accounts
• Remote
Authentication

Operations Menu

Tools Menu*

Reports Menu

• Update Library
Firmware
• Diagnostics

• FC I/O Blades**
• Port Configuration
• Channel Zoning
• Host Mapping
• Host Management
• Host Port Failover
• Data Path
Conditioning
• FC I/O Blade Control
• Encryption (if licensed)
• System Configuration
• Partition
Configuration
• System Settings
• Date & Time
• Register Library

*

Administrators only. **Available only when the library contains I/O blades.

Table 2 lists the operator panel menus. Some menu commands are
available only to administrators. I/O blade menu items are available for
libraries that contain I/O blades.

Scalar i500 User’s Guide

47

Chapter 2 Understanding the User Interface
Menu Trees

Table 2 Operator Panel
Menus

Setup Menua

Operations Menu

Tools Menu

• Partition Mgmt

• Move Media

• All RAS Ticketsa

• Create Partition

• Import Media

• Capture Snapshota

• Delete Partition

• Export Media

• Drive Mgmta

• Configure I/E Station Slots

• Import Cleaning Media

• Clean drive

• Configure Cleaning Slots

• Export Cleaning Media

• Reset drives

• Change Partition Mode

• Drive Info

• Create User

• Load Drive

• About Library

• Modify User

• Unload Drive

• User Mgmt

• Drive Settings
• Fibre
• SCSI
• SAS
• Notification

• Network Info

• Change Drive Mode
• Lock/Unlock I/E
•

Shutdowna

Stationa

• View Drive Info
• Partition Info
• Internal Networka

• System Settings
• User Session Timeout (minutes)a

• E-mail Alerts

• Touch Screen Audio

• E-mail Account

• Unload Assista

• Customer Contact

• Logical SN Addressinga

• Licenses

• Manual Cartridge Assignmenta

• Date & Time

• Disable Remote Service Usera

• Network Mgmt

• Enable SSL

• IP version 4

• Enable SNMP V1/V2

• IP version 6 (if enabled)

• Enable IPv6

• Port Settings

• Enable SMI-S

• Control Path

Scalar i500 User’s Guide

• Unlabeled Media Detection

48

Chapter 2 Understanding the User Interface
Menu Trees

Setup Menua
• FC I/O Bladesb

Operations Menu

Tools Menu
Securitya

• Port Configuration

• Network Interface

• Channel Zoning

• SSH Services

• Host Mappingc

• ICMP

• Host Managementc

• Remote UI

• Host Port Failover

• SNMP

• Data Path Conditioning

• SMI-S

• FC I/O Blade Control

Display Settings
• Brightness
• Contrast
• Defaults

• Library Testsa
• Installation & Verification Tests
• Library Demo
• View Last Summary Log
• View Last Detailed Log
• E-mail Last Detailed Log
• Blade Infob
• Port Info
• Command History Logab
aAdministrators only. bAvailable only when the library contains I/O blades. cVisible only when host mapping has

been enabled.

Scalar i500 User’s Guide

49

Chapter 2 Understanding the User Interface
User Privileges

User Privileges
User privilege levels are manually assigned to user accounts created
within the library. Controlling access to screens and operations within the
library preserves the integrity of the library and the data that is stored in
it. See Working With User Accounts on page 97 for more information on
setting user privilege levels.
Three types of users are defined in Scalar i500 libraries:
• Administrators have access to the entire physical library and all of its
partitions, and can configure the library and set up user and
administrator accounts. The library ships with a default
administrator account. The user name for the default administrator
account is admin and the password is password. You cannot modify
or delete the user name for the default administrator account, but you
can modify the password. If you misplace the password for the
default administrator account, contact Quantum Technical Support
(see Getting More Information or Help on page 8).
• Users have access to one or more assigned partitions, as well as
portions of the Operations and Reports menus. Users cannot access
the Setup and Tools menus. Users can perform functions within a
partition (such as performing cartridge and tape drive operations),
but cannot set up or configure the library (for example, creating or
deleting partitions).
• Service has access to the entire physical library and all of its partitions
as well as to a hidden Service menu that includes service and
diagnostic tools. Each library has only one service account.
Details on user privileges include:
• The library can contain eighteen user accounts (user or administrator
or both), including the default administrator account.
• Eighteen user (user or administrator or both) sessions can be active at
one time.
• The same user can be logged in to a library from multiple remote
locations.
• Clicking the close button (X) in the upper-right corner of the Web
client closes the browser window but does not log the user or
administrator out.

Scalar i500 User’s Guide

50

Chapter 2 Understanding the User Interface
User Access

• All users are logged out automatically after a configurable period of
inactivity. The default user session timeout period is 30 minutes, but
administrators can change the user session timeout to a value from 15
minutes to 480 minutes (eight hours). See Configuring System
Settings on page 126.
• A screen saver is invoked after 10 minutes of inactivity on the
operator panel. After an hour of inactivity, the screen will appear
black. If the user has not been logged out for inactivity, touching the
operator panel will reactivate it, returning the user to the screen last
in use. (The Web client does not use a screen saver.)
• An administrator can disable any access to the library from the Web
client. For more information, see Configuring System Settings on
page 126.
• When a service user logs in, all other active users are automatically
logged out.
• For security purposes, an administrator can prevent a service user
from logging on to the library remotely, from either the Web client or
over the Ethernet service port. The service user will still be able to log
on to the library from the operator panel interface. For more
information, see Configuring System Settings on page 126.

User Access
Administrators have access to the entire library. Users with user
privileges can only access some of the menus. See Table 1 on page 46 for
the Web client menu tree and privilege level information. See Table 2 on
page 48 for the operator panel menu tree and privilege level information.

Scalar i500 User’s Guide

51

F

Chapter 3

Configuring Your Library

3

Once you have installed the hardware as described in the Scalar i500
Getting Started Guide, you are ready to configure your library’s settings. A
Setup Wizard helps you get started configuring your library, and menu
commands on both the operator panel and the Web client allow you to
reconfigure your library at any time.
Caution:

Always save the library configuration after modifying
configurable items. This will allow you to restore the most
current settings if necessary. See Saving and Restoring the
Library Configuration on page 488.

This chapter covers:
• About the Setup Wizard
• Using the Setup Wizard
• Accessing the Web Client
• Managing the Network
• Working With Partitions
• Configuring Cleaning Slots
• Configuring I/E Station Slots
• Setting Tape Drive Parameters
• Working With Control Paths

Scalar i500 User’s Guide

52

Chapter 3 Configuring Your Library
About the Setup Wizard

• Obtaining and Installing a License Key
• Setting Customer Contact Information
• Configuring the Library E-mail Account
• Working With RAS E-mail Notifications
• Working With User Accounts
•

Local Authentication vs. Remote Authentication

•

Creating Local User Accounts

•

Configuring LDAP

•

Configuring Kerberos

• Setting the Date, Time, and Time Zone
• Working With FC I/O Blades
• Configuring Library Security Settings
• Configuring the Internal Network
• Configuring System Settings
• Configuring Operator Panel Display Settings
• Registering the Library

About the Setup Wizard
When you first power on the library, the operator panel displays the
Setup Wizard, which walks you through the initial configuration of the
library’s basic operational settings.
The Setup Wizard on the operator panel only runs once, at initial startup.
After that, administrators access the Setup Wizard any time via the Web
client or use commands on the Setup and Operations menus to modify all
library settings, including network settings. See Completing the Library
Configuration With Menu Commands on page 54.

Scalar i500 User’s Guide

53

Chapter 3 Configuring Your Library
About the Setup Wizard

While completing the Setup Wizard at initial startup is recommended,
you may need to begin using the library locally immediately. In this case,
you can cancel out of the Setup Wizard and allow the library to run on the
default configuration settings. See Default Configuration Settings on
page 57.
For additional information, see Using the Setup Wizard on page 55.

Using the Default
Administrator Account 3

When you power on the library for the first time, you do not need to log
in to use the operator panel. You can start using the Setup Wizard
immediately. After the initial setup session on the operator panel,
however, you will need to log in to the operator panel as well as the Web
client.
The library ships with a default administrator account. The user name on
the account is admin and the password is password. When you see the
Login screen on the operator panel or Web client, type admin in the User
Name text box and password in the Password text box. As soon as the
initial setup is complete, you should change the password on the default
administrator account. For information on changing passwords, see
Modifying Local User Accounts on page 98.

Completing the Library
Configuration With Menu
Commands
3

Note:

You cannot delete the default administrator account or modify
the user name. You can, however, change the password.

Note:

If you misplace the password for the default administrator
account, contact Quantum Technical Support (see Getting
More Information or Help on page 8).

The Setup Wizard is an aid to assist you with the initial configuration of
the library. The Setup Wizard, however, contains only a subset of
configuration tasks. The operator panel tabs and Web client menus
provide access to all configuration options that are included in the Setup
Wizard and many that are not. Once the initial Setup Wizard session is
complete, administrators can choose whichever method is most
convenient or necessary for modifying library settings.
The following topics cover using the Setup Wizard as well as Setup and
Operations commands to configure the library. Paths to open the
appropriate screens on both the operator panel and the Web client are

Scalar i500 User’s Guide

54

Chapter 3 Configuring Your Library
Using the Setup Wizard

given for each task. For the operator panel, the paths refer to the
navigation tabs at the top of the home page. For the Web client, the paths
refer to the menus.
For the menu trees on both the operator panel and Web client, see Menu
Trees on page 45.
Note:

Power cycling (powering the library on and off) is not
necessary to configure the library.

Using the Setup Wizard
The Setup Wizard simplifies the process of configuring the library. When
you first power on the library, the operator panel displays the Setup
Wizard. After that, you can no longer access the Setup Wizard from the
operator panel. You can always access the Setup Wizard from the Setup
menu on the Web client.
The recommended procedure for using the Setup Wizard for the initial
configuration is as follows:
1 Turn on the library and begin using the Setup Wizard on the operator
panel.
2 Work through all of the screens as prompted (see Setup Wizard Tasks
on page 57).
3 When you get to the network configuration screens, configure the
network settings as follows:
Note:

•

Scalar i500 User’s Guide

You cannot log into the Web client until you have
configured the network settings.

If you are using IPv4: On the Setup Wizard: Enable IPv6 screen, do
NOT select the Enable IPv6 check box. Click Next. Configure the
network settings.

55

Chapter 3 Configuring Your Library
Using the Setup Wizard

•

If you are using IPv6: On the Setup Wizard: Enable IPv6 screen,
select the Enable IPv6 check box and click Next. You have enabled
IPv6 but you will not be prompted to configure IPv6 settings
here. Continue with the Setup Wizard screens. Then, when you
are finished using the Setup Wizard, configure the IPv6 network
settings by going to Setup > Network Mgmt on the operator panel.

4 Log out of the operator panel.
5 Using the default administrator account, log in to the Web client.
Type admin in the User Name text box and password in the Password
text box.
6 Complete the Setup Wizard screens on the Web client interface. The
final Setup Wizard screen will prompt you to apply your settings.
When you have completed the Setup Wizard, the Library
Configuration report appears on the Web client. The Library
Configuration report provides information on the library’s tape
drives, partitions, I/E stations, storage slots, cleaning slots, and
loaded media. See Viewing the Library Configuration Report on
page 268 for more information on the Library Configuration report.
Note:

Depending on the size of the library, there may be a slight
delay after you apply the settings in the Setup Wizard
while the Library Configuration report page loads.

Details on using the Setup Wizard include:
• The only time that you do not need to log in to the library is when the
Setup Wizard appears on the operator panel the first time the library
is powered on.
• After a timeout period of one hour, the Setup Wizard will close, and
you will be logged out of the library. Use the default administrator
account to log in to the operator panel.
• If you time out of the Setup Wizard or do not complete all the Setup
Wizard screens, the library will apply the default configuration
settings plus whatever modifications you made (see Default
Configuration Settings on page 57).
• You cannot log in to the library from the Web client until you have
configured network settings on the operator panel. To change IPv4
settings and configure IPv6 settings, go to Setup > Network Mgmt.

Scalar i500 User’s Guide

56

Chapter 3 Configuring Your Library
Using the Setup Wizard

• You can return to the Setup Wizard from the Web client.
• Any administrators you create will also be able to use the Setup
Wizard from the Web client as well as Setup and Operations menu
commands to reconfigure the library.
• If necessary, you can cancel out of the Setup Wizard on the operator
panel and begin using the library locally with the default settings in
place. If you accept the default network configuration settings, you
will not be able to access the library remotely from the Web client.
You can, however, use Setup > Network Mgmt on the operator panel at
any time to modify network settings. See Default Configuration
Settings on page 57 for more information.

Default Configuration
Settings

3

The default configuration settings are as follows:
•

License keys: COD, 41 slots minimum. The total number depends
on number of pre-activated slots purchased.

•

Network settings: DHCP enabled, IPv6 disabled

•

Import/export (I/E) station slots: 6

•

Cleaning cartridge slots: 0

•

Partitions: By default, the library creates partitions and assigns
available library resources proportionately among the partitions,
grouping tape drives according to distinct combinations of tape
drive interface type (SCSI, FC, or SAS) and tape drive vendor. To
mix tape drive types/vendors within a partition, create partitions
manually. See Manually Creating Partitions on page 71.

See also About the Setup Wizard on page 53.

Setup Wizard Tasks

3

As you work through the Setup Wizard screens, follow the on-screen
instructions.
The Setup Wizard screens contains only a subset of all configuration
options. The Setup and Operations menus contain most configuration
options, including those in the Setup Wizard. This section includes
detailed descriptions of the configuration tasks, including how and when
to access them through the Setup and Operations menus.

Scalar i500 User’s Guide

57

Chapter 3 Configuring Your Library
Using the Setup Wizard

• Welcome (operator panel) — Welcomes you to the Setup Wizard.
• Hardware Installation (operator panel) — Reminds you to install tape
drives and the Ethernet cable.
• Setting the Date, Time, and Time Zone (operator panel and Web
client) — Allows you to set the date and time on your library.
• Managing the Network (operator panel) — Allows you to configure
your IPv4 network settings for remote access using the Web client.
Allows you to enable IPv6 so that you can configure IPv6 network
settings later using Setup > Network Mgmt.
• Applying a License Key (operator panel and Web client) — Allows
you to enter license keys for licensable features. For more
information, see Obtaining and Installing a License Key on page 88.
• Configuring Cleaning Slots (operator panel and Web client) —
Allows you to configure dedicated cleaning slots. Configuring at
least one cleaning slot enables the AutoClean feature.
• Configuring I/E Station Slots (operator panel and Web client) —
Allows you to configure import/export (I/E) station slots.
• Working With Partitions (operator panel and Web client) — Allows
you to set the number of library partitions.
• Confirm Settings (operator panel and Web client) — Allows you to
confirm your library settings.
Caution:

Note:

Scalar i500 User’s Guide

Always take a library snapshot and save the library
configuration after modifying configurable items. If
modifying items results in problems, the library snapshot
will help technical support personnel to troubleshoot the
problem. Saving the library configuration will allow you
to restore the most current settings if necessary. For more
information on taking a library snapshot and saving and
restoring the library configuration, see Saving and
Restoring the Library Configuration on page 488.

Setup Wizard operations cannot be performed concurrently by
multiple administrators logged in from different locations.
You can access the screens, but you cannot apply changes
while another administrator is performing the same operation.

58

Chapter 3 Configuring Your Library
Accessing the Web Client

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Setup Wizard.
• From the operator panel, the Setup Wizard is available only upon first
power-on of library.

Accessing the Web Client
Once you have configured network settings on the operator panel, you
can log on to the library’s Web client.
The operator panel network configuration screen lists the IP address of
the library. Use this IP address to access the Web client using a Web
browser. When typing the IP address into the Web browser, make sure to
precede it with http://; for example, http://123.123.123.123.

Managing the Network
Administrators can configure the following:
• Network settings that allow remote access to the library. For more
information, see Modifying Network Settings on page 60.
• Secure Socket Layer (SSL) settings that increase data protection so
that data from the library can be sent over the internet securely. For
more information, see Enabling SSL on page 62.
• Simple Network Management Protocol (SNMP) settings that allow
you to use an external management application to monitor the status
of the library. For more information, see Configuring SNMP Settings
on the Library on page 63.

Scalar i500 User’s Guide

59

Chapter 3 Configuring Your Library
Managing the Network

Caution:

Modifying Network
Settings

3

Security settings must be enabled to allow SNMP, SMI-S,
and IP address access to the library network. These
security settings are enabled by default. For more
information, see Configuring Library Security Settings on
page 124.

The operator panel Setup Wizard allows administrators to configure
network settings that allow remote access to the library from the Web
client. You must initially configure network settings from the operator
panel. After the initial configuration, you can modify the network
settings from either the operator panel or the Web client.
From the operator panel, you can modify the following network settings:
library name, stateless configuration enable/disable (IPv6 only), static IP
configuration enable/disable (IPv6 only), DHCP enable/disable, IP
address, subnet mask, network prefix, and default gateway.
From the Web client, you can use the Setup - Network screen to modify the
following network settings: library name; Dynamic Host Configuration
Protocol (DHCP) enable/disable; stateless autoconfiguration
enable/disable (IPv6 only); static IP enable/disable (IPv6 only), IP
address; subnet mask (IPv4 only); net prefix (IPv6 only); and default
gateway address.
In addition, from the Web client, when DHCP is disabled, can configure
the primary and secondary Domain Name System (DNS) server
addresses. DNS servers provide IP address resolution of fully qualified
domain names. DNS settings are optional.
If you modify the IP address, you will need to type the new IP address in
the Address field of your Web browser to access the Web client.
Note:

Scalar i500 User’s Guide

Make sure that the library is connected to the network before
modifying network settings. If the Ethernet cable is not
installed properly, you cannot configure the network settings.
Install one end of the Ethernet cable in the top Ethernet port of
the library control blade (LCB) just below the three LEDs. The
LCB is located at the back of the control module. Make sure
the other end of the Ethernet cable is installed in the
appropriate LAN port on your LAN.

60

Chapter 3 Configuring Your Library
Managing the Network

Details on network settings include:
• Library Name is the network name you want to assign to the library.
The library name is limited to 12 lowercase alphanumeric characters
and dashes (-).
• DHCP defaults to enabled. When DHCP is enabled, the library obtains
an IP address automatically. If DHCP is not enabled, you must
manually enter an IP address, default gateway, and subnet mask/net
prefix.
• IPv4 addresses must be entered in dot notation (for example,
192.168.0.1). They are limited to numeric characters and do not allow
values exceeding 255 for dot-separated values.
• IPv6 addresses must be entered in the proper notation. IPv6 address
can be entered in the most common notation, as eight groups of four
hexadecimal digits. 2001:0ff8:55cc:033b:1319:8a2e:01de:1374 is an
example of a valid IPv6 address. Also, if one or more of the four-digit
groups contains 0000, you can omit the zeros and replace them with
two colons (::), as long as there is only one double colon used in an
address. Using this notation, 2001:0ff8:0000:0000:0000:0000:01de:1374
is the same as 2001:0ff8::01de:1374.
• IP Address is the IP address of the library. For IPv4, this text box is
available only if DHCP is disabled.
• Default Gateway Address is the IP address of the default gateway for
your portion of the Ethernet network. For IPv4, this text box is
available only if DHCP is disabled.
• Subnet Mask (IPv4 only). Text box is available only if DHCP is
disabled.
• Network Prefix (IPv6 only).
• Primary DNS Address (optional, Web client only) must be entered as
an IP address. This text box is available only if DHCP is disabled.
• Secondary DNS Address (optional, Web client only) must be entered
as an IP address. This text box is available only if DHCP is disabled.
• Port Settings (operator panel only) allows you to change the
autonegotiate mode, speed, and duplex settings on the Ethernet port.

Scalar i500 User’s Guide

61

Chapter 3 Configuring Your Library
Managing the Network

Caution:

Modifying network settings will modify network
connectivity parameters, requiring remote communication
configuration changes. Your current Web client browser
session might become invalid, requiring you to close your
current browser session. Access the Web client using the
new network configuration settings and log in again.

Note:

Be sure to add your library’s IP address to the list of
trusted/allowed sites on your library-supported browser, so
the Web client pages automatically refresh.

Note:

For step-by-step network configuration instructions, see your
library’s online Help. To access the online Help system, click
the Help icon at the top right of the Web client or operator
panel user interface.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Network Management > Network.
• From the operator panel, select Setup > Network Mgmt.

Enabling SSL

3

Administrators can enable or disable SSL settings on the library. Enabling
SSL settings encrypts all Web browser connections to the Web client, and
it enables SSL-based authentication for SMI-S. SMI-S is the newest
standard of SNMP, which makes sets of data continuously available.
SMI-S is disabled by default. You can enable SMI-S on the Tools > System
Settings screen on the operator panel.
The default SSL setting is Disabled. Disabling SSL settings creates an
unencrypted connection from a Web browser to the Web client.
See the Scalar Intelligent Libraries SMI-S Reference Guide (6-01317-xx) for
further configuration and access details.

Scalar i500 User’s Guide

62

Chapter 3 Configuring Your Library
Managing the Network

Note:

Before enabling SSL settings, make sure you enter a name for
the library in the Library Name text box when configuring
network settings (Setup > Network Mgmt on the operator
panel). After enabling SSL settings, use that library name to
access the library. If you do not use that name, you will receive
a security alert. In addition, make sure to complete all the text
boxes listed on the Web client Contact Information screen
(Setup > Notification > Contact Information) before enabling SSL
settings. This information is used to identify company
information in the SSL certificate.

You cannot enable the SSL settings from the Web client. The path to open
the appropriate screen is as follows:
• From the operator panel, select Tools > System Settings > Enable SSL.

Configuring SNMP
Settings on the Library 3

SNMP is a light-weight protocol designed for remote management and
monitoring of infrastructure devices. The library provides SNMP
support, so an external management application can be configured to
receive library SNMP information. The library supports SNMP by
publishing a Management Information Base (MIB) that can be queried to
obtain the status of the library and many of its individual components.
SNMP information can be obtained from the library using SNMP Traps
and GET queries.
For more information about SNMP, see the Scalar i500 Basic SNMP
Reference Guide (6-01370-xx). For information on integrating MIBs with an
SNMP management application, contact your network management
application vendor.
Administrators can perform the following SNMP procedures:
• Register the IP addresses and port numbers of external management
applications, enabling them to receive SNMP traps from the library.
For more information, see Registering External Management
Applications on page 64.
• Enable or disable support for SNMP v1 and v2c. SNMP v3 is enabled
by default and cannot be disabled. For more information, see
Enabling SNMP Versions on page 65.
• Choose which version of SNMP the library uses to report traps. You
can choose SNMPv1 or SNMPv2. The default is SNMPv1.

Scalar i500 User’s Guide

63

Chapter 3 Configuring Your Library
Managing the Network

• Modify the default SNMP community string, which is used as a
password to authenticate GET and GET-NEXT SNMP v1 and SNMP
v2c messages exchanged between the library and a remote
management application. For more information, see Modifying the
SNMP Community String on page 66.
• Enable or disable SNMP authentication traps, which are messages
indicating an authentication failure. For more information, see
Enabling and Disabling SNMP Authentication Traps on page 67.
• Download the library MIB, which can be used to integrate the library
with an SNMP management application. For more information, see
Downloading the SNMP MIB on page 67.

3

Registering External Management Applications

Administrators can register transport protocols, IP addresses, and port
numbers of external management applications to enable them to receive
SNMP traps from the library. (By default, the library ignores all SNMP
SET operations, so external management applications cannot register
themselves to receive SNMP traps from the library.)
After registering the transport protocols, IP addresses, and
corresponding port numbers, you can perform a test to verify that the
library can send the SNMP traps to the addresses.
When registering external management applications to receive SNMP
traps, you can set the following parameters:
• Transport — The transport protocol. This should be the same as the
transport protocol configured on the SNMP trap receiver. Select one
of the following:
•

UDP/UDP6 — User Datagram Protocol. For IPv4, select UDP; for
IPv6, select UDP6.

•

TCP/TCP6 — Transmission Control Protocol. For IPv4, select
TCP; for IPv6, select TCP6.

• Host Name/IP Address — The host name or the IP address of the
external management application you want to register. A host name
may be entered only if DNS is enabled. Otherwise, IP addresses must
entered. For information on DNS, see Modifying Network Settings on
page 60.
• Port — the port number of the external application you want to
register. The default port number for an external application is 162.
Scalar i500 User’s Guide

64

Chapter 3 Configuring Your Library
Managing the Network

• Create — Adds the IP address and port number of the external
application to the list of registered addresses that will be sent SNMP
traps.
• Delete — Allows you to delete a selected IP address and port number.
• Test — Verifies only that the library has sent SNMP traps to all
registered IP addresses. Check the external applications to verify that
the traps were received.
While the test is in progress, the Progress Window appears. If the test
is successful, Success appears in the Progress Window and the traps
were successfully sent. If the test is unsuccessful, Failure appears in
the Progress Window. Follow the instructions listed in the Progress
Window to resolve any issues that occur during the operation.
See the Scalar i500 Basic SNMP Reference Guide (6-01370-xx) for further
configuration and access details.
Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

The path to open the appropriate screen is as follows:
• From the Web client select Setup > Network Management > SNMP Trap
Registrations.

3

Enabling SNMP Versions
The library supports SNMP v1, v2c, and v3.

Administrators can enable or disable support for SNMP v1 and v2c. The
recommended practice is to disable SNMP v1 and SNMP v2c in highly
secure environments.
SNMP v3 is always enabled and cannot be disabled. The authentication
algorithm is set to MD5, and the encryption is disabled system-wide.
See the Scalar i500 Basic SNMP Reference Guide (6-01370-xx) for further
configuration and access details.

Scalar i500 User’s Guide

65

Chapter 3 Configuring Your Library
Managing the Network

The paths to open the appropriate screens are as follows:
• From the Web client select Setup > Network Management > SNMP.
• From the operator panel select Tools > System Settings > Enable
SNMP V1/V2.
Choosing SNMP Trap Versions

3

The library supports SNMP v1 and v2 traps as defined by RFC 1157 (v1 is
the default). Administrators can choose which version the library uses to
report traps (v1 is the default)
The timeout for all SNMP requests to the library must be at 10 seconds or
greater (command line parameter-t).
The path to open the appropriate screen is as follows:
• From the Web client select Setup > Network Management > SNMP.
Modifying the SNMP Community String

3

Administrators can modify the SNMP community string. The SNMP
community string is a text string that acts as a password to authenticate
GET and GET-NEXT SNMP v1 and SNMP v2c messages exchanged
between the library and an external management application. The SNMP
community string used by the library must match the string used by the
external management application.
The default SNMP community string on the library is: publicCmtyStr. For
security purposes, this string should be modified. When modifying the
community string, adhere to the following guidelines: the community
string is case-sensitive, cannot be empty, and cannot exceed 32 characters.
See the Scalar i500 Basic SNMP Reference Guide (6-01370-xx) for further
configuration and access details.
You cannot modify the SNMP community string from the operator panel.
The path to open the appropriate screen is as follows:
• From the Web client select Setup > Network Management > SNMP.

Scalar i500 User’s Guide

66

Chapter 3 Configuring Your Library
Managing the Network

Enabling and Disabling SNMP Authentication Traps

3

Administrators can enable or disable SNMP authentication traps. When
the library receives an SNMP message that does not contain the correct
community string or other authentication information, the library sends
an SNMP authentication trap message to registered remote management
systems, indicating the authentication failure. SNMP authentication traps
are disabled by default.
See the Scalar i500 Basic SNMP Reference Guide (6-01370-xx) for further
configuration and access details.
You cannot enable or disable SNMP authentication traps from the
operator panel. The path to open the appropriate screen is as follows:
• From the Web client select Setup > Network Management > SNMP.
Downloading the SNMP MIB

3

The library supports an SNMP MIB that can be used to integrate the
library with commercial SNMP management applications. The MIB can
be queried to obtain the status of the library and many of its individual
components. Administrators can download the SNMP MIB from the
library. The MIB can then be installed on an SNMP external management
application.
For more information about the library MIB, see the Scalar i500 Basic
SNMP Reference Guide(6-01370-xx) or contact Quantum Technical Support
(see Getting More Information or Help on page 8). For information on
integrating MIBs with an SNMP management application, contact your
network management application vendor.
Note:

The SNMP MIB is also available on the Scalar i500
Documentation and Training CD.

You cannot download the SNMP MIB from the operator panel. The path
to open the appropriate screen is as follows:
• From the Web client select Tools > Download SNMP MIB.

Scalar i500 User’s Guide

67

Chapter 3 Configuring Your Library
Working With Partitions

Working With Partitions
Partitions are virtual sections within a library that present the appearance
of multiple, separate libraries for purposes of file management, access by
multiple users, or dedication to one or more host applications. The library
must contain at least one unassigned tape drive and slot to create a
partition.
The Setup Wizard: Partitioning screens allow administrators to select the
number of new library partitions to create.
At any time after the initial configuration of the library, administrators
can create, modify, and delete partitions by selecting Setup > Partitions on
the Web client, or create and delete partitions by selecting Setup >
Partition Mgmt on the operator panel.
There are two ways to create partitions:
• Automatically — Library resources are assigned proportionately
among the partitions. Tape drives are grouped according to their
interface type (SCSI, FC, or SAS), tape drive vendor, and media
generation (LTO-3, LTO-4, LTO-5, LTO-6). You cannot mix interface
type, tape drive vendor, and media generation in partitions that you
create automatically. To create a partition with mixed interface types,
tape drive vendors, and media generations, you must create the
partition manually. You can create partitions automatically on either
the operator panel or the Web client. When you automatically create
partitions, you add to the number of existing partitions.
• Manually — An administrator creates one partitions at a time and
allocates resources as desired. You can mix tape drive interface types,
tape drive vendor, and media generations in partitions that you
create manually. You can create partitions manually only on the Web
client. When you manually create partitions, you add to the number
of existing partitions.
Note:

Scalar i500 User’s Guide

You may not mix drive vendor types (for example, HP
and IBM) in partitions that are configured for library
managed encryption (see Step 6: Configuring Partitions
for Library Managed Encryption on page 180).

68

Chapter 3 Configuring Your Library
Working With Partitions

The maximum number of partitions that can be created is equal to the
number of drives in the library. Table 3 shows the possible number of
partitions that can be created for each of the available library
configurations.

Table 3 Number of Partitions
Supported

Available
Configurations

Tape Drives
Minimum, Maximum

Partitions
Minimum, Maximum

5U

1, 2

1, 2

14U

1, 6

1, 6

23U

1, 10

1, 10

32U

1, 14

1, 14

41U

1, 18

1, 18

Details on partitions include:
• Administrators can create, modify, delete, and control access to all
partitions. Users can be given access to only certain partitions and
denied access to others.
Partition names are limited to 12 lower-case alphanumeric characters and
underscores (_).
• The maximum number of partitions that can be created is equal to the
number of tape drives in the library.
• At minimum, a partition consists of one tape drive and one slot. The
tape drive or slot cannot be shared with another partition.
• I/E station slots are shared between all partitions. Partitions take
temporary ownership of I/E station slots when importing or
exporting tape cartridges.
Caution:

Scalar i500 User’s Guide

Before permanently removing an expansion module from
your library, you need to perform a set of configuration
operations that includes deleting all partitions. See
Deleting Partitions on page 74 and Removing the
Expansion Module on page 365.

69

Chapter 3 Configuring Your Library
Working With Partitions

Automatically Creating
Partitions
3

At any time after the initial configuration of the library, administrators
can add to the number of existing partitions by using the automatic
partitioning process. Automatic partitioning assigns available library
resources proportionately among the partitions, grouping tape drives
according to their interface type (SCSI, FC, or SAS), tape drive vendor,
and media generation. The default number of partitions created is the
number of distinct tape drive interface/vendor/media type combinations
of the tape drives that are not currently assigned to a partition. You
cannot mix tape drive interface types, vendors, or media generations in
partitions that you create automatically. To create a partition with mixed
interface types, vendors, and media generations you must create the
partition manually (see Manually Creating Partitions on page 71).
For example:
•

If your library contains two tape drives, an FC IBM LTO-4 and an FC
IBM LTO-5, two partitions would be created because although they
have the same interface type, they have different media generations
(LTO-4 and LTO-5).

•

If your library contains two tape drives, a Fibre Channel IBM LTO-4
and a Fibre Channel HP LTO-4, two partitions would be created
because the tape drive vendors are different.

On the Automatically Create Partitions screen, you can select the number
of partitions to create, from a minimum of the default specified by the
library to a maximum that equals the number of unassigned tape drives
in your library.
The library must contain at least one unassigned tape drive and one
unassigned slot to automatically create a partition. If no unassigned tape
drives or slots exist, you must modify or delete one or more partitions to
free up resources. For more information, see Modifying Partitions on
page 73 and Deleting Partitions on page 74.
When the library automatically creates partitions, it creates control paths.
See Working With Control Paths on page 86 for a description of the
default control paths and how to change them.
By default, the library applies the Standard barcode format to each
partition. You can change this setting by modifying the partitions after it
has been created. For information on modifying partitions, see Modifying
Partitions on page 73.

Scalar i500 User’s Guide

70

Chapter 3 Configuring Your Library
Working With Partitions

Note:

This operation cannot be performed concurrently by multiple
administrators logged in from different locations. You can
access the screen, but you cannot apply changes while another
administrator is performing the same operation.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Partitions.
• From the operator panel, select Setup > Partition Mgmt > Create
Partition.

Manually Creating
Partitions

3

Using the Web client, administrators can manually create additional
partitions any time after the initial configuration of the library. The
maximum number of partitions that can be created is equal to the number
of drives in the library.
You can mix tape drive interface type, vendor, and media generation in
partitions that you create manually. Exception: You may not mix tape
drive vendor types (for example, HP and IBM) in partitions that are
configured for library managed encryption (see Step 6: Configuring
Partitions for Library Managed Encryption on page 180).
The library must contain at least one unassigned tape drive and slot to
create a partition. If no tape drives or slots are available, you must modify
or delete an existing partition to free up resources. For more information,
see Modifying Partitions on page 73 and Deleting Partitions on page 74.
When you manually create partitions, the library creates control paths.
See Working With Control Paths on page 86 for a description of the
default control paths and how to change them.
When creating partitions manually, you need to provide the following
information:
• Partition Name — Limited to a maximum of 12 lower-case
alphanumeric characters and underscores (_)
• Emulation Type — This setting allows the partition to appear as a
different library type to the host. In most cases, you can ignore this
setting and just use the default. However, if your host application
does not support the default and cannot recognize the partition using

Scalar i500 User’s Guide

71

Chapter 3 Configuring Your Library
Working With Partitions

the default setting, you can choose a library type that your host has
previously qualified. This makes the partition appear to the host as
the selected library type and should allow the host to communicate.
•

ADIC Scalar i500 (default)

•

Quantum Scalar i500

•

Quantum Scalar i2000

•

ADIC Scalar i2000

•

ADIC Scalar 100

•

ADIC Scalar 24

• Media Barcode Format — This setting tells the library how to read and
report barcodes of the tape cartridges in the partition. The library
supports the following options (for definitions of each of the options,
see Supported Barcode Formats on page 521).
•

Standard (default)

•

Standard Six

•

Plus Six

•

Extended

•

Media ID Last

•

Media ID First

• Number of Slots — The number of storage slots allocated to the new
partition.
• Drives — The tape drive or drives assigned to the partition.

Scalar i500 User’s Guide

Note:

Before creating partitions, verify that all tape drives are
unloaded. For information on unloading tape drives, see
Unloading Tape Drives on page 252.

Note:

Creating Partitions operations cannot be performed
concurrently by multiple administrators logged in from
different locations. You can access the screen, but you cannot
apply changes while another administrator is performing the
same operation.

72

Chapter 3 Configuring Your Library
Working With Partitions

You cannot create partitions manually from the operator panel. The path
to open the appropriate screen is:
• From the Web client, select Setup > Partitions.

Mixing Tape Drive Types
Within Partitions
3

When you automatically create partitions, tape drives with different
interface types, vendor types, and media generation are placed in
different partitions. If you manually create partitions, you can mix tape
drive types as follows.
• For non-encrypted partitions and for partitions that use Application
Managed Encryption:
•

SCSI, FC, and SAS tape drives can be mixed.

•

HP and IBM tape drives can be mixed.

•

Different media generations (for example, LTO-3, LTO-4, LTO-5)
can be mixed.

• For partitions that use Library Managed Encryption:
•
•

Tape drives must be FC or SAS. FC and SAS tape drives can be in
the same partition.
Q-EKM partitions can only contain IBM LTO-4 and IBM LTO-5

tape drives.
•

SKM partitions can only contain HP LTO-4 and HP LTO-5 tape

drives.

For more information on partitions with Library Managed Encryption,
see Step 6: Configuring Partitions for Library Managed Encryption on
page 180.

Modifying Partitions

3

Using the Web client, administrators can modify partition settings any
time after the partition is created.
The tape drive set as the control path for a particular partition cannot be
deleted from that partition. The check box associated with the control
path is grayed out. For more information on setting the control path, see
Working With Control Paths on page 86.
The library automatically takes the partition offline before modifying it
and places the partition back online after it is modified.

Scalar i500 User’s Guide

73

Chapter 3 Configuring Your Library
Working With Partitions

Note:

If the operation does not complete successfully, the partition
remains offline until you turn it back online manually or
restart the library (see Taking a Partition Online or Offline on
page 76).

When modifying a partition, you may need to provide the following
information:
• Emulation Type — This setting allows the partition to appear as a
different library type to the host. See Manually Creating Partitions on
page 71 for a description and available options.
• Partition Name — limited to a maximum of 12 lower-case
alphanumeric characters and underscores (_).
• Media Barcode Format — This setting tells the library how to read and
report barcodes of the tape cartridges in the partition. The default
selection is Standard (for definitions of each of the options, see
Supported Barcode Formats on page 521).
• Number of Slots — the number of tape cartridge slots allocated to the
partition.
• Drives — the tape drive or drives assigned to the partition.
Note:

Before deleting a tape drive from a partition, verify that it is
unloaded. For information on unloading tape drives, see
Unloading Tape Drives on page 252.

You cannot modify partitions manually from the operator panel. The
path to open the appropriate screen is:
• From the Web client, select Setup > Partitions.

Deleting Partitions

3

A partition can be deleted when it is no longer needed or in preparation
for removing a module from the library. Administrators can delete one
partition at a time.
Unload all tape drives and export all cartridges assigned to the partition
that is to be deleted. After exporting the cartridges, remove them from the
I/E station. For more information, see Unloading Tape Drives on
page 252 and Exporting Media on page 249.

Scalar i500 User’s Guide

74

Chapter 3 Configuring Your Library
Working With Partitions

Details about deleting partitions include the following:
• After a partition is deleted, its resources (for example, tape drives and
slots) become available and can be reassigned to new or existing
partitions.
• Deleting a partition does not delete users assigned to that partition.
However, if these users are not assigned to other partitions, they will
not be able to perform library operations. See Changing Partition
Access on page 75.
• Because partitions may extend across the library’s physical modules
and share resources, the library will report errors if you permanently
remove or replace a module in your library without first deleting or
modifying partitions and modifying shared resources such as
cleaning slots and I/E slots. See Preparing to Remove or Replace a
Module on page 356 for detailed instructions on preparing your
library for the permanent removal or replacement of a module.
Note:

You may need to modify settings in your host application as a
result of deleting a partition. See your host application
documentation.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Partitions.
• From the operator panel, select Setup > Partition Mgmt.

Changing Partition
Access

3

An administrator can control which partitions a specified user can access
by modifying the user’s account. Also, any user assigned to a partition
that has been deleted can be reassigned to other partitions.
To change partition access, you must provide the following information:
• Password — A unique password that can be viewed and modified by
the administrator.
• Privilege Level — Determines the user’s access privileges. See User
Privileges on page 50 for more information on user privilege levels.
• Partition Access — the partitions to which the user has access.

Scalar i500 User’s Guide

75

Chapter 3 Configuring Your Library
Working With Partitions

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > User Management > User
Accounts.
• From the operator panel, select Setup > User Mgmt > Modify User.

Taking a Partition Online
or Offline
3

There are two partition modes: online and offline.
• Online — SCSI hosts control the partition. In this mode, all host
application SCSI commands are processed.
• Offline — SCSI hosts cannot control the partition. In this mode,
library operations can be performed via the operator panel or Web
client.
This topic focuses on using the library user interface to manually change
a partition mode to online or offline. Changing a partition mode using the
library user interface may affect your host application. See your host
application documentation for more information.
Details about changing the partition mode include:
• When you access the Change Partition Mode screens, you will see only
partitions to which you have been given access.
• The Online/Offline buttons toggle between modes.
• If a partition is in use, the Online/Offline button is grayed out.
• Restarting the library will bring all offline partitions back online (see
Restarting the Library on page 239).

Scalar i500 User’s Guide

Note:

Some maintenance activities require that the entire library be
taken offline. To take the library offline, change the mode of all
partitions from online to offline.

Note:

When changing the partition mode from online to offline, all
host application commands in progress at the start of the
mode change are completed.

76

Chapter 3 Configuring Your Library
Working With Partitions

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Partitions > Change Mode.
• From the operator panel, select Operations > Change Partition Mode.

Disabling/Enabling
Manual Cartridge
Assignment

3

Administrators can disable or enable manual cartridge assignment. When
manual cartridge assignment is enabled (the default setting), the Assign
I/E screen automatically appears on the operator panel once cartridges are
placed into the I/E station. The Assign I/E screen prompts you to use the
operator panel to assign the cartridges to a specific partition or to the
system partition.
When manual cartridge assignment is disabled, the Assign I/E screen does
not appear on the operator panel, and the cartridges in the I/E station
remain unassigned until they are moved or imported into the library.
For more information on how manual cartridge assignment affects
importing of media, see Importing Media on page 242.
You can disable manual cartridge assignment by clearing the Manual
Cartridge Assignment check box on the operator panel System Settings
screen. For more information on system settings, Configuring System
Settings on page 126.

Manual cartridge assignment cannot be configured from the Web client.
The path to open the appropriate screen is as follows:
• From the operator panel, select Tools > System Settings.
Understanding Host Application Notification

3

When manual cartridge assignment is enabled, SCSI Unit Attention
6/2801 notifies the host application when the I/E station has been
accessed, allowing the host to automatically detect the presence of media
in the I/E station and update its I/E station status information.
When manual cartridge assignment is disabled, host notification via SCSI
Unit Attention 6/2801 depends on the number of configured partitions:
• If multiple partitions are defined, the host application is not notified
when the I/E station has been accessed. Media presence in the I/E
station is reported to any partition requesting it.

Scalar i500 User’s Guide

77

Chapter 3 Configuring Your Library
Configuring Cleaning Slots

• If a single partition is defined, the host application is notified when
the I/E station has been accessed. Media presence is reported to the
sole defined partition, as well as to the system partition, when either
of these partitions checks for changes in the status of the I/E station.
For information about using the host to perform tape operations, see your
host application documentation.

Configuring Cleaning Slots
Cleaning slots are used to store cleaning cartridges that are used to clean
tape drives. The Setup Wizard: Cleaning Slot Configuration screens prompt
you to enter the number of cleaning slots (if any) you want to designate
for your library. You can also access the Cleaning Slot Configuration
screens directly on the operator panel and Web client.
Note:

Only slots that are licensed, unassigned, and empty can be
used for cleaning. If there are unassigned slots, but no cleaning
slots available, make sure there are no RAS tickets for
unassigned media.

The Setup Wizard default configuration settings include zero dedicated
cleaning slots. Configuring at least one cleaning slot enables the library’s
AutoClean feature. When AutoClean is enabled, the library allows you to
import and export cleaning cartridges. When a tape drive needs cleaning,
it notifies the library. If AutoClean is enabled, the library automatically
cleans the tape drive using a cleaning cartridge loaded in a cleaning slot.
Note:

If you configure zero I/E station slots, you will not be able to
import or export cleaning cartridges using I/E stations. See
Configuring I/E Station Slots on page 79.

Cleaning slots are not assigned to specific partitions. Each partition can
access cleaning cartridges located in the dedicated cleaning slots.
The maximum number of cleaning slots that can be configured is four. To
disable AutoClean, configure zero cleaning slots.
Administrators can configure cleaning slots during the initial library
configuration and at any time after that, as long as unassigned slots are
Scalar i500 User’s Guide

78

Chapter 3 Configuring Your Library
Configuring I/E Station Slots

available. If no slots are available in the library, you must modify or
delete a partition to free up slots. For more information see Modifying
Partitions on page 73 and Deleting Partitions on page 74.
Administrators can also clean tape drives manually. For information, see
Manually Cleaning Tape Drives on page 260.
Note:

Cleaning slots are not visible to the host application. To choose
host-based cleaning, do not configure any cleaning slots, and
configure your host application to manage cleaning tape
drives. Configuring cleaning slots on the library may affect the
host application. See your host application documentation for
information.

Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the screen, but you cannot apply changes while
another administrator is performing the same operation.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Cleaning Slots.
• From the operator panel, select Setup > Partition Mgmt > Configure
Cleaning Slots.

Configuring I/E Station Slots
I/E station slots are used to import and export tape cartridges into and
out of the library without disrupting normal library operations. The
Setup Wizard: I/E Station screens allow you to configure I/E station slots.
Administrators can also configure these slots on either the operator panel
or the Web client.
Each control module contains six I/E station slots, and each expansion
module contains 12 I/E station slots. The available library configurations
support a minimum of six I/E slots in the 5U library to a maximum of 54
I/E slots in the 41U library configuration. You can also choose to
Scalar i500 User’s Guide

79

Chapter 3 Configuring Your Library
Configuring I/E Station Slots

configure zero I/E station slots and use all slots in all I/E stations for tape
cartridge storage. For more information on configuring zero I/E slots, see
Configuring Zero I/E Station Slots on page 82.
Each I/E station (6-slot or 12-slot) is configured as a complete unit. When
configuring an I/E station, configure all the slots in the I/E station the
same way: all storage or all I/E slots.
If the library consists of a control module, all six I/E station slots must be
configured either as storage or as I/E station slots. A 14U library consists
of a control module (with six I/E station slots) and an expansion module
(with 12 I/E station slots). All 12 of the slots in the expansion module
must be configured the same way, as either I/E station slots or storage
slots. Therefore, a 14U library can contain a minimum of six and a
maximum of 18 dedicated I/E station slots. Table 4 lists the number of
I/E station slots available per library for all base library configurations.

Scalar i500 User’s Guide

80

Chapter 3 Configuring Your Library
Configuring I/E Station Slots

Table 4 Number of I/E Station
Slots Available

Library
Configuration

5U Control Module

9U Expansion Module

Library Total

I/E
Stations

I/E
Slots

I/E
Stations

I/E
Slots

I/E
Stations

I/E
Slots

5U

1

6

–

–

1

6

14U

1

6

1

12

2

18

23U

1

6

2

24

3

30

32U

1

6

3

36

4

42

41U

1

6

4

48

5

54

Details on configuring I/E station slots include:
• Before changing the number of I/E station slots, remove all tape
cartridges from any slots currently configured as I/E station slots.
• An I/E station that has been configured for storage may contain
cleaning slots. These cleaning slots must be deleted before you can
reconfigure the storage slots as I/E station slots.
• The default number of dedicated I/E slots is six. If you accept the
Setup Wizard default configuration settings, six I/E slots will be
created in the control module.
• If you increase the size of your library by adding expansion modules,
the I/E stations in the new modules will be storage slots by default.
You can select to reconfigure these slots as I/E slots.
• Based on the number of I/E slots you configure, the library
automatically determines which I/E stations to configure as I/E slots
and which to configure as storage.
• The library configures I/E slots in the control module I/E station first
and then works outward to the I/E stations in the expansion
modules. I/E stations in expansion modules below the control
module have precedence over I/E stations in expansion modules
above the control module.

Scalar i500 User’s Guide

81

Chapter 3 Configuring Your Library
Configuring I/E Station Slots

• All slots in an I/E station must be configured the same way: as either
storage or I/E slots. For this reason, if your library includes one or
more expansion modules and you configure an even number of I/E
slots greater than six, the control module I/E station may be
configured automatically as storage.
• If the I/E station is configured as data storage slots, its door is always
locked. For information on unlocking I/E stations, see Locking and
Unlocking the I/E Stations on page 262.
• I/E station slots are shared by all partitions within a library.
• To identify how a specific I/E station magazine is configured, view
the Library Configuration report available from the Reports menu on
the Web client. See Viewing the Library Configuration Report on
page 268.

Configuring Zero I/E
Station Slots

3

Configuring zero I/E slots increases the number of storage slots in your
library but has the following consequences:
• You will not be able to use the I/E station to import and export tape
cartridges, including cleaning media.
• You will be required to open the library access door to bulk load and
unload tape cartridges, disrupting library operations. See Bulk
Loading on page 246.
• You will not be able to manually clean tape drives with a cleaning
cartridge.
For more information on using the I/E station to import and export
media, see Running Your Library on page 237.
Caution:

Note:

Scalar i500 User’s Guide

Configuring I/E station slots with cartridges already
loaded compromises data security. First, remove
cartridges from the I/E station and then configure the I/E
station slots.

This operation cannot be performed concurrently by multiple
administrators logged in from different locations. You can
access the screen, but you cannot apply changes while another
administrator is performing the same operation.

82

Chapter 3 Configuring Your Library
Setting Tape Drive Parameters

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > I/E Station Slots.
• From the operator panel, select Setup > Partition Mgmt > Configure I/E
Station Slots.

Setting Tape Drive Parameters
Administrators can view and modify certain tape drive parameters. You
can set the SCSI ID for a SCSI-attached tape drive. You can set the loop
IDs, topology connection mode, and interface speed for a Fibre-attached
tape drive. You can view but not set parameters for SAS tape drives. A
SAS tape drive’s SAS address is automatically and uniquely generated
based on a unique World Wide Node Name (WWNN) that the drive
receives when it is configured.
If the affected partition is online, it will be taken offline before the
parameters are set, and brought back online after they are set.

Note:

If the operation does not complete successfully, the partition
remains offline until you turn it back online manually or
restart the library (see Taking a Partition Online or Offline on
page 76).

Each device on a SCSI bus, including the host bus adapter (HBA) needs to
have a unique SCSI ID. Changing the SCSI ID is necessary when there is a
duplicate ID on a single bus. Typically, the HBA SCSI ID is set to 7. For
example, if two tape drives are connected together on the same bus, each
tape drive must have different SCSI IDs and they must be different from
the HBA SCSI ID.
For SCSI tape drives, you can set the SCSI ID to a value from 0 to 15. The
library assigns the following default SCSI IDs to SCSI tape drives:
• Control module: 1 and 2
• Each expansion module: 3, 4, 5, and 6

Scalar i500 User’s Guide

83

Chapter 3 Configuring Your Library
Setting Tape Drive Parameters

For FC tape drives:
• DPF (Data Path Failover) — You can enable data path failover on HP
LTO-5 Fibre Channel tape drives with a Storage Networking license
by selecting the DPF check box (see Configuring Data Path Failover
on page 154).
• The loop ID can be set to a value from 0 to 125. A unique loop ID is
selected by default for all FC tape drives installed in the library. For
example, the tape drive installed in the top drive bay of a control
module is assigned a default loop ID of 61. The tape drive installed in
the control module’s bottom drive bay is assigned a default loop ID
of 63.
If you change the default loop IDs, make sure each FC tape drive with
a topology setting of Auto (LN), Loop (L), or Auto (NL) has a unique
loop ID.
You cannot change the Loop ID if the Topology is set to Point to
Point.
• The requested topology connection mode can be set to one of the
following:

Scalar i500 User’s Guide

•

Auto (LN) — Auto-configure trying L-Port first

•

Loop (L) — Force L-Port

•

Point to Point — Force N-Port

84

Chapter 3 Configuring Your Library
Setting Tape Drive Parameters

•

Auto (NL) — Auto-configure trying N-Port first (default)

Notes About Point to Point:
- You can use Point to Point if the tape drive is connected
via a switch.
- You can use Point to Point with HP drives if the tape
drive is connected to a host.
- You cannot use Point to Point if the tape drive is
connected directly to a host.
- You cannot use Point to Point if the tape drive is
connected to an FC I/O blade.
- You must use Point to Point if the tape drive is being
used for control path failover (see Configuring Control
Path Failover on page 150) or data path failover (see
Configuring Data Path Failover on page 154). If a tape
drive is being used for control path failover or data path
failover, you cannot change its topology from Point to
Point to anything else.
• The requested interface speed can be set to Auto (default), 1 Gb/s,
2 Gb/s, 4 Gb/s, or 8 Gb/s (depending on drive type).
Caution:

LTO-5 Fibre Channel tape drives can be configured for
speeds of up to 8 Gb/s. If they are configured for
8 Gb/s, you should connect them directly to a host
and not to an FC I/O blade, because the FC I/O blade
only allows speeds up to 4 Gb/s. If you connect an
LTO-5 Fibre Channel tape drive to an FC I/O blade,
you must configure the tape drive speed to 4 Gb/s or
less.

• If the requested FC topology and speed settings are not supported,
the next appropriate settings are negotiated. On the Web client, the
Drive Settings screen displays both the requested and the actual FC
topology connection mode and interface speed. If FC drives are not
connected to the host, the negotiated actual settings appear on the
screen as “unknown.”
Note:

Scalar i500 User’s Guide

On the Web client, the Drive Settings screen displays tape
drive information in tables. Bold column headings in the tables
can be sorted. For example, selecting the Location column
heading will sort by location coordinates.

85

Chapter 3 Configuring Your Library
Working With Control Paths

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Drive Settings.
• From the operator panel, select Setup > Drive Settings.

Working With Control Paths
The control path tape drive is used to connect a partition to a host
application.
The library automatically assigns control paths when you set up
partitions. You can modify the control path at any time. Table 5 describes
how these control paths are assigned and how to change them.

Table 5 Control Path
Assignment During Partition
Creation

If the library
contains:
No FC I/O
blades

And the
partition
contains:
Any
combination
of tape drive
interface types
(SCSI, FC, or
SAS)

Scalar i500 User’s Guide

Then the
default
control path
for the
partition is:
The first tape
drive assigned
to the partition

If you want to change the control path, note
the following:
You must select a tape drive as the control path.

86

Chapter 3 Configuring Your Library
Working With Control Paths

If the library
contains:

And the
partition
contains:

Then the
default
control path
for the
partition is:

One or more
FC I/O blades

At least one
FC tape drive

The FC I/O
blade

If you want to change the control path, note
the following:
Using the FC I/O blade as the control path allows
you to utilize the LUN mapping and host port
failover features.
You can select a tape drive as control path if the
tape drive is not connected to an FC I/O blade.
However, it is recommended that you allow the
FC I/O blade to be the control path for the
partition.
You cannot select a tape drive as control path if
the tape drive is connected to an FC I/O blade.

One or more
FC I/O blades

No FC tape
drives

The first tape
drive assigned
to the partition

You must select a tape drive as the control path.

Only one tape drive in a partition can be selected as the control path per
partition. In the event that the control path connection to the host
application fails, you can select a new control path for the partition.
Additionally, if the control path for the partition is an HP LTO-5 Fibre
Channel tape drive and you have Storage Networking licensed on the
library, you can select another HP LTO-5 Fibre Channel tape drive for
control path failover (see Configuring Control Path Failover on page 150
for details).
The Setup > Control Path screens list a selected partition’s tape drives,
including the tape drive that is currently designated as the control path.
You can designate a new control path for the partition by selecting a
different tape drive. You can also disable a partition’s control path by
clearing the current control path selection.
Caution:

Scalar i500 User’s Guide

Do not select an FC tape drive as control path if it is
connected to an FC I/O blade. The control path will be
filtered out by the I/O blade and will not be visible to the
host.

87

Chapter 3 Configuring Your Library
Obtaining and Installing a License Key

Note:

You may need to modify settings in your host application as a
result of modifying the control path. See your host application
documentation.

Note:

Bold column headings in the table can be sorted. For example,
selecting the Location column heading will sort by location
coordinates.

Note:

If you have more than one FC I/O blade in the library, each FC
I/O blade will present each partition — that does not have a
tape drive as the control path — as a target device to the host.
Thus the host may see the same partition multiple times. To
minimize confusion, you should configure host mapping so
that each host sees each device only once. See Configuring
Host Mapping on page 118.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Control Path.
• From the operator panel, select Setup > Control Path.

Obtaining and Installing a License Key
Several features can be added to the standard library configuration either
with your initial purchase or afterward (see Licensable Features on
page 32).
This section describes how to license these features on your library, in the
following sections:
• About License Keys
• Viewing Licenses and License Keys
• Obtaining a License Key
• Applying a License Key

Scalar i500 User’s Guide

88

Chapter 3 Configuring Your Library
Obtaining and Installing a License Key

About License Keys

3

If you purchase a licensable feature with your library, the license will be
installed when you receive the library. If you upgrade or add new
features after the initial purchase, Quantum issues you a license key
certificate. The license key certificate contains an authorization code that
enables you to retrieve your license key from the Quantum Web site.
Once you install the license key on the library, the feature becomes
available.
Details about license keys include:
• An authorization code to obtain a license key can be used one time
only.
• The license key may contain up to 12 alphanumeric characters. The
license key can also contain the “at” (@), hyphen (-), or underscore (_)
symbols. Alpha characters must be lowercase. The user interface
automatically converts entries to lowercase.
• A given license key can only be used on the library to which it is
assigned and cannot be transferred to another library. The key is
verified when it is applied to the library to make sure it is the proper
key associated with the library serial number.
• License keys do not expire.
• Once installed on the library, license keys cannot be removed (unless
you replace the control module or the library control blade (LCB)
compact flash card).

Scalar i500 User’s Guide

•

If you replace the control module: The license key is associated
with the serial number of the control module. If you replace your
control module, you must replace all your installed license keys.
Request replacement license keys from Quantum.

•

If you replace the LCB compact flash: The LCB compact flash card
contains information about your library configuration. If you
replace your LCB compact flash card, you must reinstall your
license key(s) onto the library. You may be able to reinstall them
yourself if you have saved the license keys or can retrieve them
from the Web sites listed above. In some cases, factory installed
license keys will not be listed on the Web site and you will need
to contact Quantum for a replacement. If you cannot retrieve
your license keys or need assistance, contact Quantum.

89

Chapter 3 Configuring Your Library
Obtaining and Installing a License Key

Viewing Licenses and
License Keys

3

To see the licenses you have purchased and obtained, go to:
http://www.quantum.com/licensekeys.The license history for each
feature is listed (feature licensed, amount licensed, authorization code,
and date license key was obtained). The most recent license contains the
full amount of the license for that feature (for example, the most recent
COD license contains the total number of COD slots licensed) and
replaces previous license keys.
To see which licensable features are enabled on your library, go to the
Licenses screen:
• From the Web client, select Setup > License.
• From the operator panel, select Setup > Licenses.

Obtaining a License Key 3

To obtain your license key for a new feature or upgrade:
1 Contact your Quantum technical sales representative to submit your
order for the feature or upgrade. See Getting More Information or
Help on page 8.
2 Upon receipt of your order, Quantum will ship you a license key
certificate containing your authorization code.
Note:

If you order more than 46 COD slots:

COD licenses come in 46-slot increments. If you order
more than 46 slots, you will receive more than one license
key certificate. For example, if you want to activate 92
slots, you will receive two license key certificates. You
need to follow the procedure outlined here twice, once for
each certificate. However, because each additional license
key replaces the previous ones, you only need to apply one
license key (the final one) to the library.
3 On your library, locate the serial number. You will need the Serial
Number to retrieve your license key from the Web site. To view the
serial number:
•

On the operator panel, select Tools > About Library, or

•

On the Web client, select Reports > About > Scalar i500.

4 Access the Quantum License Key Management Web site at
http://www.quantum.com/licensekeys.

Scalar i500 User’s Guide

90

Chapter 3 Configuring Your Library
Obtaining and Installing a License Key

5 In the Serial Number box, enter your serial number.
6 Click Submit.
If you have entered a valid serial number, the Web site displays
existing license keys for this feature. Exception: If the license was
applied at the factory, the word “Factory” may appear instead of the
actual license key. If you need to retrieve the license key in this case,
contact Quantum Technical Support (see Contacts on page 7).
7 Type the authorization code from your License Key Certificate in the
Authorization Code text box.
8 Click the Get License Key button.
If you have entered a valid authorization code, the Web site allows
you to retrieve the license key for your new feature or upgrade.
You are now ready to apply the license key to the library. See Applying a
License Key.

Applying a License Key 3

A license key may be applied to the library during the initial
configuration or whenever licensed features are purchased. If increased
capacity is purchased, the new license key will replace the current license
key.
Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the screen, but you cannot apply changes while
another administrator is performing the same operation.

Caution:

Note:

While you are installing a license key, backup operations
may be interrupted.

If you have more than one license key to apply, you may enter
them all at the same time, separated by a space or a hyphen.

You can enter the license key on the Setup Wizard: Licensing screen, and
you can also use commands on the operator panel or Web client to
directly enter a license key at any time after exiting the Setup Wizard.
You may need to refresh your Internet browser after installing a license
key to see the new menus and functionality.

Scalar i500 User’s Guide

91

Chapter 3 Configuring Your Library
Setting Customer Contact Information

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > License.
• From the operator panel, select Setup > Licenses.

Setting Customer Contact Information
Administrators can use the Web client to enter contact information into
the library for the person who is the primary customer contact for the
library. Keep this information current to expedite the Service process.
When a problem occurs with the library, the contact information is
mailed to techsup@quantum.com along with Reliability, Availability, and
Serviceability (RAS) ticket information, assuming that the default e-mail
notification has been configured. For information on configuring the
default e-mail notification see Creating RAS E-mail Notifications on
page 95.
You can set customer contact information from the Web client only, but
you can view it from the operator panel.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Notifications > RAS > Contact
Information.
• From the operator panel, select Setup > Notification.

Configuring the Library E-mail Account
The library uses the library e-mail account whenever library e-mail
services are used, such as when the library automatically sends e-mail
notifications about library issues.
Before configuring the e-mail account, ask your network administrator
for an IP address, valid login account (optional), and valid password

Scalar i500 User’s Guide

92

Chapter 3 Configuring Your Library
Configuring the Library E-mail Account

(optional) for your SMTP server. The login account name and password
can contain the following special characters: @ and #. E-mail account
settings are not case-sensitive.
After configuring the e-mail account, you can send a test message to an
e-mail address to verify that the account is configured properly.
The Setup > Notifications > E-mail Configuration screen contains the
following options:
• SMTP Server includes the IP address or host name of the SMTP
server. IP addresses must be entered in dot notation (for example,
192.168.0.1) and cannot exceed 255.
• Sender E-mail Address includes an e-mail address for the library (for
example, “libraryname@mycompany.com”). The library uses this
address in the From field of e-mail messages that it sends out,
indicating the originator of the message.
Send snapshot with e-mail notifications instructs the library to
automatically attach a library snapshot file (ASCII format) to certain RAS
ticket e-mail notifications (see Working With RAS E-mail Notifications on
page 94). (Snapshots are only auto-generated for this purpose if they help
to clarify or diagnose the problem.) This feature is turned off by default.
Library snapshot files can also be sent to specified e-mail addresses using
the Capture Snapshot operation (see Capturing Snapshots of Library
Information on page 485). If the library is in the process of capturing an
automatic snapshot, you will not be able to manually capture a snapshot
via the Web client until the automatic snapshot is complete. If this
happens, an error message will display. Wait about 10 minutes and try
again.

• Authentication includes a means to enter the login account name and
password for the library. Selecting the box enables use
authentication. Clearing the box disables use authentication. The
following fields are only available if use authentication is enabled:

Scalar i500 User’s Guide

•

Login Account includes the name of a valid account on the SMTP

•

Password is the password for the account that you specified in
the Login Account text box. The password can contain the
following special characters: @ and #.

server (for example, “John.User”). The login account name can
contain the following special characters: @ and #.

93

Chapter 3 Configuring Your Library
Working With RAS E-mail Notifications

•

Send a test e-mail to allows you to enter an e-mail address you
want to test. Enter the address and click Send e-mail. Then check

the e-mail account to verify that an e-mail message was sent from
the library.
After configuring the e-mail account, save the library configuration. For
information, see Saving and Restoring the Library Configuration on
page 488.
You can configure the library e-mail account from the Web client only,
but you can view e-mail account information from the operator panel.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Notifications > E-mail
Configuration.
• From the operator panel, select Setup > Notification > E-Mail Account.

Working With RAS E-mail Notifications
The library can be configured to automatically send e-mail notifications
to specified e-mail addresses whenever an issue of a particular severity
level occurs with one of its components. The information in the e-mail
notification provides details about the issue and the library conditions at
the time of the error.
Before you can configure e-mail notifications, you must configure the
library’s e-mail account so that the library can send notifications to the
designated recipients. See Configuring the Library E-mail Account on
page 92 for information on how to configure the e-mail account.
See Creating RAS E-mail Notifications on page 95 for information on
setting up additional e-mail notifications. The library supports a
maximum of 20 e-mail notification recipients, including the default
support e-mail notification.
Note:

Scalar i500 User’s Guide

RAS e-mail notifications are closed when the library reboots.
From the operator panel, select Tools > System Settings to
configure this setting.

94

Chapter 3 Configuring Your Library
Working With RAS E-mail Notifications

Note:

The default techsup@quantum.com e-mail notification settings
can be modified, but not deleted. The e-mail address,
techsup@quantum.com, cannot be modified.

There are three e-mail notification filter levels:
• All tickets
• High and urgent tickets only
• Urgent tickets only
) Administrators can configure the library e-mail account and e-mail
notifications. Users can receive e-mail notifications, but they cannot
configure the library e-mail account and/or notifications.
You can configure e-mail notifications from the Web client only, but you
can view them from the operator panel.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > Notifications > RAS > Receiver
Addresses.
• From the operator panel, select Setup > Notification > E-mail Alerts.

Creating RAS E-mail
Notifications

3

Administrators can create e-mail notifications. The library supports a
maximum of 20 e-mail notification recipients, including the default
support e-mail notification. Each e-mail notification recipient must have a
unique e-mail address.
To set e-mail notifications, you need to provide the e-mail address and
filter level setting for the recipient. For more information on filter levels,
see Working With RAS E-mail Notifications.
Each e-mail notification includes an optional Comments text box you can
use to enter important system configuration details, such as the network
environment or third-party software applications that interface with the
library. Such information will appear in the body of the e-mail and can
help technical support personnel to troubleshoot the library.

Scalar i500 User’s Guide

95

Chapter 3 Configuring Your Library
Working With RAS E-mail Notifications

Note:

Do not enter more than one address in the Enter E-mail
Address text box. If you need to send e-mail notifications to
multiple addresses, create an e-mail notification for each
e-mail address.

The path to open the appropriate screen is as follows:
• From the Web client, select Setup > Notifications > RAS > Receiver
Addresses > Create.

Modifying RAS E-mail
Notifications

3

Administrators can modify existing e-mail notification settings at any
time after the e-mail notification is created. For example, you can modify
the e-mail address; add, delete, or modify a comment; change the filter
level; and enable or disable the notification. For more information on
filter levels, see Working With RAS E-mail Notifications on page 94.
Note:

The default techsup@quantum.com e-mail notification settings
can be modified, but not deleted. The e-mail address,
techsup@quantum.com, cannot be modified.

The path to open the appropriate screen is as follows:
• From the Web client, select Setup > Notifications > RAS > Receiver
Addresses > Modify.

Deleting RAS E-mail
Notifications

3

Administrators can delete an e-mail notification when it is no longer
needed.
Note:

The default techsup@quantum.com e-mail notification settings
can be modified, but not deleted. The e-mail address,
techsup@quantum.com, cannot be modified.

The path to open the appropriate screen is as follows:
• From the Web client, select Setup > Notifications > RAS > Receiver
Addresses > Delete.

Scalar i500 User’s Guide

96

Chapter 3 Configuring Your Library
Working With User Accounts

Working With User Accounts
Administrators can create local user accounts on the library for local
authentication, or enable and configure the Lightweight Directory Access
Protocol (LDAP) for remote authentication. You may use either or both
methods, according to your needs. This section covers how to set up user
accounts and authentication for both local and remote authentication.

Local Authentication vs.
Remote Authentication 3

Local authentication control is managed on the library. An administrator
sets up accounts and privileges on the library. To use local authentication,
a user must enter a local user name and password.
Remote authentication is managed by an LDAP server. Enabling LDAP
allows existing user accounts residing on an LDAP server to be integrated
into the library’s current user account management subsystem. User
account information is centralized and shared by different applications,
simplifying user account management tasks.
To use remote authentication, you must enable LDAP on the library.
Once LDAP is enabled, users can log into the library using either LDAP
or local authentication. See Logging In When LDAP or Kerberos is
Enabled on page 240 for more information.

About Local User
Accounts

3

Administrators can create and modify two types of local user accounts:
user and administrator. These users have different library privilege
levels.
• User — has access to one or more assigned partitions and can
perform functions within a partition, such as performing media and
tape drive functions. A user cannot perform actions that affect the
physical library, such as creating, modifying, or deleting a partition.
• Administrator — has access to the entire physical library and all of its
partitions.
The library ships with a default administrator account. The user name for
this account is admin and the password is password. You cannot delete
this user account or change the user name, but you can change the
password. The default administrator account is used to perform the
initial configuration of the library. If you misplace the password for the

Scalar i500 User’s Guide

97

Chapter 3 Configuring Your Library
Working With User Accounts

default administrator account, contact Quantum Technical Support. See
Getting More Information or Help on page 8.
See User Privileges on page 50 for more information on library
permission levels. For information on changing passwords, see
Modifying Local User Accounts on page 98.

Creating Local User
Accounts

3

During or after the initial configuration, you can use the default
administrator account to create up to eighteen additional local user
accounts, including other administrator accounts. These administrators
can themselves create other local administrator and user accounts. Users
without administrator privileges cannot create accounts. The library can
contain eighteen user accounts, including the default administrator
account.
To create local user accounts, you need to provide information for the
following fields:
• User Name — the login name of the user account you are creating.
User names are limited to 1–12 lower-case letters, numbers, and
underscores (_). For example: john_usa.
• Password — the unique password for the user account you are
creating. Passwords are limited to 6–16 lower-case alphanumeric
characters and can include also include underscores (_), periods (.),
hyphens (-), asterisks (*), and the “at” symbol (@). For example:
pass_19.
• Privilege — is set to either User or Admin. See User Privileges on
page 50 for more information on user privilege levels.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > User Management > User
Accounts.
• From the operator panel, select Setup > User Mgmt> Create User.

Modifying Local User
Accounts

Scalar i500 User’s Guide

3

After a local user account has been created, administrators can modify the
account settings, such as the password, privilege level, and partition
access. You cannot modify the user name. Instead, you will need to delete
the user account and create a new one.

98

Chapter 3 Configuring Your Library
Working With User Accounts

To modify local user accounts, you need to provide information for the
following fields:
• Password — the unique password for the user account you are
creating. Passwords are limited to 6–16 lower-case alphanumeric
characters and can include also include underscores (_), periods (.),
hyphens (-), asterisks (*), and and the “at” symbo (@). For example:
pass_19.
• Privilege — set to either User or Admin. See User Privileges on page 50
for more information on user privilege levels.
• Partition Access — the partitions to which this user has access. Any
user assigned to a partition that has been deleted can be reassigned to
other partitions.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > User Management > User
Accounts.
• From the operator panel, select Setup > User Mgmt > Modify User.

Deleting Local User
Accounts

3

Administrators can delete other local administrator and user accounts
when they are no longer needed.
Note:

The default administrator account cannot be deleted.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > User Management > User
Accounts.
• From the operator panel, select Setup > User Mgmt > Modify User.

Configuring LDAP

3

Administrators can enable and configure Lightweight Directory Access
Protocol (LDAP). LDAP is the industry standard Internet protocol that
provides centralized user account management.
Administrators can add, delete, and modify only local user account
information. The library Web client does not allow you to create, modify,
or delete user account information on an LDAP server. This must be done
by the directory service provider. For more information on working with
local user accounts, see About Local User Accounts on page 97.

Scalar i500 User’s Guide

99

Chapter 3 Configuring Your Library
Working With User Accounts

The library supports all LDAP servers. You can also use Kerberos for
added security. For specific instructions on configuring Kerberos, see
Configuring Kerberos on page 104.
The Login screen displays remote authentication login options only when
LDAP is enabled.

3

LDAP Server Guidelines
The following groups must be created on the LDAP server to enable
remote login on the library:
• Library user group — Assign users to this group who need userprivilege access to the library. Enter the name of this group in the
Library User Group field on the Setup - Remote Authentication screen
on the library Web client (see Configuring LDAP on the Library on
page 101).

• Partition groups — For LDAP users with user privileges, access to
library partitions is determined by group assignment on the LDAP
server. Groups must be created on the LDAP server with names that
match the library partition names (names must match but are not
case sensitive). Users with user privileges must be assigned to these
groups on the LDAP server to have access to the corresponding
partitions on the library.
• Library admin group — Assign users to this group who need
administrator-privilege access to the library. LDAP users with
administrator privileges have access to all partitions and
administrator functions and do not need to be assigned to partitionrelated groups on the LDAP server. Enter the name of this group in
the Library Admin Group field on the Setup - Remote Authentication
screen on the library Web client (see Configuring LDAP on the
Library on page 101).
You will need to have at least one user assigned to both the Library User
Group and the Library Admin Group on the LDAP server in order to test
the LDAP settings on the library (see Testing LDAP Settings on page 103).
Since most normal users will not be members of both these groups, you
may need to create a special or temporary user specifically for this
purpose.

Scalar i500 User’s Guide

100

Chapter 3 Configuring Your Library
Working With User Accounts

3

Configuring Secure LDAP on the Library
Configuring Secure LDAP is optional. You can configure Secure LDAP
using one of the following methods (do not use both).

• LDAPS — Uses Secure Sockets Layer (SSL) over a specific port for
LDAP (636). You may enable LDAP over SSL (LDAPS) by entering a
URI in the form of “ldaps://hostname” in the Server URI field. This
will use SSL to send secure communication via port 636. If the LDAP
server does not support LDAPS or does not have LDAPS enabled,
then login operations will fail. LDAPS has been deprecated in favor
of using StartTLS (see option below). Do not use LDAPS if you are
using StartTLS. Once you apply LDAPS, StartTLS will not be
available.
• StartTLS — Uses Transport Layer Security (TLS) over the same port
as regular LDAP (389). Select the StartTLS check box to configure
secure LDAP communication using TLS. If TLS mode is not
supported on your LDAP server, then login operations will fail. Do
not use StartTLS if you are using LDAPS. See Figure 15 on page 103.

3

Installing an LDAP TLS CA Certificate

If you are using LDAPS or StartTLS, you can also install a TLS CA
certificate for additional verification that the LDAP server has not been
compromised. The certificate must be the same certificate that is installed
on your LDAP server and must be in .pem format. The library will only
perform the verification if you have configured Secure LDAP (using
either LDAPS or StartTLS). Place a copy of the certificate file in an
accessible location on your computer and use the Browse button to locate
and install it. Once a certificate is installed, you can remove it by selecting
the Remove TLS CA Certificate check box. See Figure 15 on page 103.

3

Configuring LDAP on the Library
Before configuring LDAP, obtain the following LDAP parameters from
your network administrator. You need to enter these parameters in the
Setup - Remote Authentication screen on the Web client.

• Server URI — The Uniform Resource Identifier (URI) of the LDAP
server where user account information is stored. The URI includes
the LDAP server host name or IP address and can include the LDAP
server network port. Port 389 is the default.
Scalar i500 User’s Guide

101

Chapter 3 Configuring Your Library
Working With User Accounts

Examples:
ldap://hostname:389
ldap://10.50.91.103
ldap://mycompany.com
• LDAPS — Optional. See Configuring Secure LDAP on the Library on
page 101.
• StartTLS — Optional. See Configuring Secure LDAP on the Library
on page 101.
• Install TLS CA Certificate — Optional. See Installing an LDAP TLS CA
Certificate on page 101.
• Remove TLS CA Certificate — This check box is available if a TLS CA
certificate is installed. You can remove the certificate by selecting this
check box. The certificate will be removed after you click Apply.
• Principal — An LDAP user login ID with permissions to search the
LDAP directory. The library logs on to LDAP using this ID. For an
example, see Figure 15 on page 103.
• Password — The password for the principal authorization login ID.
• User DN — The Fully Qualified Distinguished Name that contains the
users. For an example, see Figure 15 on page 103.
• Group DN — The Fully Qualified Distinguished Name that contains
the groups. For an example, see Figure 15 on page 103.
• Library User Group — The value of the Common Name attribute for
the group entry on the LDAP server associated with library users
who have user-level privileges (see User Privileges on page 50 for
information on privilege levels). This group must exist on your LDAP
server (see LDAP Server Guidelines on page 100). For an example,
see Figure 15 on page 103.
• Library Admin Group — The value of the Common Name attribute for
the group entry on the LDAP server associated with library users
who have administrator-level privileges (see User Privileges on
page 50 for information on privilege levels). This group must exist on
your LDAP server (see LDAP Server Guidelines on page 100). For an
example, see Figure 15.

Scalar i500 User’s Guide

102

Chapter 3 Configuring Your Library
Working With User Accounts

Figure 15 LDAP Setup
Example
The simple LDAP server
configuration shown below would
give the library settings shown at
right.

Simple LDAP Server Configuration:

3

Testing LDAP Settings

The Test Settings button tests communication between the library and the
LDAP server, and tests the currently applied LDAP settings. If there are
any problems, an error message identifies the problem area.
If you change the LDAP settings, click Apply to save your changes before
testing them. Otherwise, any changes you made will be lost and will not
be tested.
To test the settings, you must type a user name and password, then click
the Test Settings button. The user you use for the test must be a member of
both the Library User Group and the Library Admin Group on the LDAP
server. Since most normal users will not be members of both these

groups, you may need to create a special or temporary user specifically
for this purpose.
After configuring LDAP settings, save the library configuration.

Scalar i500 User’s Guide

103

Chapter 3 Configuring Your Library
Working With User Accounts

Note:

For step-by-step instructions on configuring LDAP on the
library, see your library’s online Help. To access the online
Help system, click the Help icon at the top right of the Web
client.

You can view, enable, and configure LDAP settings from the library Web
client. You cannot use the operator panel to configure LDAP settings.
The path to open the appropriate screen is as follows:
• From the Web client, select Setup > User Management > Remote
Authentication.

Configuring Kerberos

3

Use Kerberos if you want extra security with remote authentication.
Make sure that both the library and the Kerberos/Active Directory®
server are set to the same time (within 5 minutes). Otherwise, the
authentication will fail. It is recommended that you use Network Time
Protocol (NTP) to synchronize the time between the library and the
Kerberos server. See Setting the Date and Time Using the Network Time
Protocol on page 107.
Fill in the following Kerberos fields in addition to all the LDAP fields:
• Realm — The Kerberos realm name, typed in all uppercase letters.
Usually the realm name is the DNS domain name.
Example: MYCOMPANY.COM
• KDC (AD Server) — The key distribution center (in other words, the
server on which Kerberos/Active Directory is installed).
Example: mycompany.com:88
• Domain Mapping — The domain portion of the library’s fully qualified
domain name.
Example: mycompany.com
• Service Keytab — Click the Browse button to select the service keytab
file. The service keytab file is a file you generate on your
Kerberos/Active Directory server. See Generating the Service Keytab
file on page 105.
You can view, enable, and configure Kerberos settings from the Web
client. You cannot use the operator panel to configure Kerberos settings.

Scalar i500 User’s Guide

104

Chapter 3 Configuring Your Library
Working With User Accounts

The path to open the appropriate screen is as follows:
• From the Web client, select Setup > User Management > Remote
Authentication.
Generating the Service Keytab file

3

These instructions are for generating the service keytab file for use with
Microsoft® Active Directory®. If you not using Active Directory, refer to
your Kerberos vendor for instructions on generating this file.
1 Set up an Active Directory domain on the Windows server.
2 If Active Directory is not already configured, run dcpromo.
3 Windows 2003 servers only: Install Windows Support Tools on the
Windows 2003 server as follows:
a

Go to www.microsoft.com and search for “windows server 2003
support tools sp2” or click on the following link:
http://www.microsoft.com/downloads/details.aspx?FamilyID
=96a35011-fd83-419d-939b-9a772ea2df90&DisplayLang=en

b

Download both support.cab and suptools.msi.

c

Run suptools.msi to begin installation.

4 Create a computer account in Active Directory.
•

Do not select any of the check boxes during creation.

•

The account name will be used for  fields
shown in the following steps.

5 At the command prompt, map SPN to the computer account. Use the
following format:
setspn -A library/ 

For example:
setspn -A library/delos.dvt.mycompany.com kerbtest

Scalar i500 User’s Guide

105

Chapter 3 Configuring Your Library
Setting the Date, Time, and Time Zone

6 At the command prompt, create the keytab file for the SPN. Use one
of the following formats:
•

For Windows 2003:
ktpass -out library.keytab -princ
library/@
+rndPass -ptype KRB5_NT_SRV_HST -crypto RC4-HMAC-NT mapUser /computers/

For example:
ktpass -out library.keytab -princ
library/delos.dvt.mycompany.com@OURREALM.LOCAL
+rndPass -ptype KRB5_NT_SRV_HST -crypto RC4-HMAC-NT mapUser ourrealm.local/computers/kerbtest
•

For Windows 2008:
ktpass -out library.keytab -princ library/
@
+rndPass -ptype KRB5_NT_SRV_HST -crypto AES256-SHA1
-mapUser /computers/

For example:
ktpass -out library.keytab -princ
library/delos.dvt.mycompany.com@OURREALM.LOCAL
+rndPass -ptype KRB5_NT_SRV_HST -crypto AES256-SHA1
-mapUser ourrealm.local/computers/kerbtest

Setting the Date, Time, and Time Zone
Administrators can either set the library date, time, and time zone
settings manually or configure the Network Time Protocol (NTP).
Note:

Scalar i500 User’s Guide

The following operations should not be performed
concurrently by multiple administrators logged in from
different locations. You can access the appropriate screens, but
you cannot apply changes while another administrator is
performing the same operation.

106

Chapter 3 Configuring Your Library
Setting the Date, Time, and Time Zone

Setting the Date and Time
Manually
3

Note:

For step-by-step date and time configuration instructions, see
your library’s online Help. To access the online Help system,
click the Help icon at the top right of the Web client or operator
panel user interface.

Note:

The library may log you off after you change the time or time
zone. If this happens, simply log back on.

The Setup Wizard - Date & Time screen allows you to set the date and time
for the library. You can also access the date and time setup screen by
selecting Date & Time from the Setup menu on either the operator panel or
the Web client.
Date and time settings are used to log the date and time events take place
and to set the time for automatic backup and restore functions. At a
minimum, you should set the library’s date and time as part of the initial
library configuration.
The time is set to a 24 hour clock. For example, four o’clock in the
afternoon is entered as 16:00.

Setting the Date and Time
Using the Network Time
Protocol
3

The library supports the Network Time Protocol (NTP). NTP allows you
to synchronize the library date and time with other components in your
IT infrastructure. Administrators can either modify the date and time
zone settings manually or configure NTP.
If NTP is enabled, the time zone and IP addresses of at least one NTP
server must be configured on the library. Contact your network
administrator for NTP server IP address information.
You can use the Web client Setup Wizard - Date & Time screen to enable
and configure NTP. You can also access the date and time setup screen by
selecting Date & Time from the Setup menu on the Web client.
Details on NTP settings include:
• NTP servers must be configured in available in groups of 3 or more,
with one exception: a single NTP server configuration is also allowed.

Scalar i500 User’s Guide

107

Chapter 3 Configuring Your Library
Setting the Date, Time, and Time Zone

• NTP is enabled on the Date & Time screen. When NTP is enabled, you
cannot manually configure date and time. For more information on
setting date and time manually, see Setting the Date and Time
Manually on page 107.
• You can enter an IP address for a primary and an alternate (optional)
NTP server.
• NTP server IP addresses must be entered in the proper format. See
Modifying Network Settings on page 60 for the proper format of IPv4
and IPv6 addresses.
• After you apply NTP settings, system clock synchronization may take
several minutes.
You can only enable and configure NTP on the Web client. The path to
open the appropriate screen is as follows:
• From the Web client, select Setup > Date & Time.

Setting the Time Zone

3

To select your time zone from a list, disable Use Custom Time Zone setting
and select your time zone.
If your time zone does not appear on the list, or you want more control
over your time settings, enable Use Custom Time Zone and set a Universal
Coordinated Time (UTC) offset.
You can only set the time zone on the Web client. The path to open the
appropriate screen is as follows:
• From the Web client, select Setup > Date & Time.

Setting Daylight Saving
Time
3

If you selected your time zone from the drop-down list (see Setting the
Time Zone), the library automatically adjusts for daylight saving time.
There is no need to manually reset the clock for time changes.
However, if you set a custom time zone, the library will not automatically
adjust for daylight saving time. You must enable the Use Custom Daylight
Saving Time setting. Once enabled, you can set start and stop times to an
accuracy of one minute.
You can only set daylight saving time on the Web client. The path to open
the appropriate screen is as follows:
• From the Web client, select Setup > Date & Time.

Scalar i500 User’s Guide

108

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Working With FC I/O Blades
The library supports optional FC I/O blades, which provide host
connections to LTO-2, LTO-3, LTO-4, LTO-5 and LTO-6 FC drives. The
number of FC I/O blades in any library configuration cannot exceed four,
and each FC I/O blade in the library supports up to four FC tape drives.
FC I/O blades reduce switch port and cabling requirements and increase
backup reliability. When tape drives are connected to FC I/O blades, the
library proactively checks the status and readiness of the data paths from
the hosts through the FC I/O blade to the FC tape drives.
In addition, two powerful features provide ways to manage the
interaction between hosts and target devices:
• Channel zoning allows you to control access between FC I/O blade
ports configured for host servers and ports configured for target
devices. For more information, see Configuring FC I/O Blade
Channel Zoning on page 111.
• Host Mapping allows you to control visibility to target devices and
access from individual host servers to target devices. For more
information, see Managing FC Hosts and Host Mapping on page 113.
The topics in this section cover configuring FC I/O blades. For additional
information on FC I/O blades, see:
• Fibre-Channel Input/Output Blades on page 26
• Controlling FC I/O Blade Power on page 263
• Viewing FC I/O Blade Information on page 275
• Viewing FC I/O Blade Port Information on page 276
• Cabling Libraries With Fibre Channel Tape Drives Connected to
Fibre Channel I/O Blades on page 308
• Recommended Library Cabling for FC I/O Blades on page 313
• Identifying FC I/O Blades on page 496
• Resetting FC I/O Blade Ports on page 498
Note:

Scalar i500 User’s Guide

FC I/O blade menu commands are available for use only
when FC I/O blades are installed in the library.

109

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Configuring FC I/O Blade
Ports
3

When FC I/O blades are installed, administrators can configure FC I/O
blade port parameters.
Each FC I/O blade has six ports. Ports 1 and 2 are always target ports and
are configurable. Ports 3 through 6 are always initiator ports and are not
configurable. For information on viewing the current configured settings
for all I/O blade ports, see Viewing FC I/O Blade Port Information on
page 276.
Details on configuring FC I/O blade ports include:
• The Setup - I/O Blade Port Configuration screen lists all I/O blades
found in the library. The screen lists the following information for
each I/O blade: location in the library, World Wide Node Name
(WWNN), status, and ports. You can select the I/O blade target port
(1 or 2) you want to configure and proceed to the next screen. For the
target port you selected, the screen displays the World Wide Port
Number (WWPN).
• For the selected target port (ports 1 and 2), you can configure the
following parameters:
•

Loop ID — Loop IDs can be set to Auto or a hard value from 0
through 125. Selecting Auto automatically selects a unique loop

ID. Some FC host operating systems require hard loop ID
settings. The default setting is Auto.

•

Speed — The interface speed can be set to Auto, 1 Gb/s, 2 Gb/s, or
4 Gb/s. Selecting Auto automatically sets the interface speed. The
default setting is Auto.

•

Frame Size — Frame size can be set to 512, 1024, or 2048. The
default setting for ports 1 and 2 is 2048. Your FC host might
require a different setting.

•

Connection — The connection mode for the ports can be set to
Loop, Loop Preferred, or Point to Point. The default setting is Loop
Preferred.

• After modifying these parameters, save the library configuration. For
instructions on how to save the library configuration, see Saving and
Restoring the Library Configuration on page 488.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > FC I/O Blades > Port Configuration.
• From the operator panel, select Setup > I/O Blades > Port
Configuration.
Scalar i500 User’s Guide

110

Chapter 3 Configuring Your Library
Working With FC I/O Blades

FC I/O Blade Internal
Virtual Port for Media
Changers

3

Configuring FC I/O Blade
Channel Zoning
3

Scalar i500 User’s Guide

FC I/O blades use an internal virtual port to access the media changer
devices (partitions). Each FC I/O blade can access all media changer
devices, except those that are defined in association with drive-based
access (also known as “LUN-1”). The Scalar i500 library can have up to 18
partitions. These internal virtual ports are not configurable via channel
zoning; thus, all media changer devices are accessible via ports 1 and 2 of
each FC I/O blade present within the library. This may lead to one or
more media changer devices being discovered multiple times, depending
on how the system is connected to host servers (for example, if four
partitions are defined in a system that has two FC I/O blades, there
would be four media changer devices visible on ports 1 and 2 of both FC
I/O blades, for a total of 16). To minimize unnecessary discovery of
media changer devices, you need to configure host mapping. See
Managing FC Hosts and Host Mapping on page 113.

When FC I/O blades are installed in the library, administrators can
configure channel zoning for selected FC I/O blades. Channel zoning,
also called port zoning, configures access to an entire FC and all the
LUNs on that channel for the exclusive use of a host or group of hosts on
a single port. Channel zoning enables you to control access between
specific target ports 1 and 2 and initiator ports 3–6 on an FC I/O blade.
Note:

Channel zoning acts upon the FC tape drive LUNs seen
through the initiator ports on the FC I/O blade. Channel
zoning does not affect media changer (partition) LUNs. If you
want to map hosts to media changer LUNs though an FC I/O
blade, you must use the FC I/O blade’s FC host mapping
feature. For information on FC host mapping, see Managing
FC Hosts and Host Mapping on page 113.

Note:

If both channel zoning and host mapping are enabled, the
channel zoning settings supersede any host LUN mapping on
the FC I/O blade.

111

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Details on configuring channel zoning include:
• By default, all target FC ports (ports 1 and 2) on an FC I/O blade have
access to all initiator ports (ports 3–6).
• Changing channel zoning setting will cause the affected FC I/O blade
to reboot.
• If host port failover is enabled on the FC I/O blade, channel zoning
must be configured so that all target FC ports have access to all
initiator ports. For information on host port failover, see Configuring
FC Host Port Failover on page 119.
• The Setup - FC I/O Blade Channel Zoning screen on the Web client lists
all FC I/O blades found in the library. FC I/O blades are listed by the
following: location in the library, WWNN, and status. The
corresponding Channel Zoning Select Blade screen on the operator
panel lists the location in the library and state. You can select the FC
I/O blade you want to configure for channel zoning and proceed to
the next screen.
• The two FC target ports (ports 1 and 2) and the four FC initiator ports
(ports 3–6) are displayed in a grid, with the target ports listed in
columns and the initiator ports listed in rows. Check boxes allow you
to associate a target port with an initiator port.

Scalar i500 User’s Guide

•

To permit access, select the check box at the intersection of the
target port and the initiator port. You can associate each initiator
port with more than one target port.

•

To restrict access, clear the check box at the intersection of the
target port and the initiator port.

•

When you select a check box, the entire FC channel is zoned. This
zoning affects any host application that might be accessing the
FC I/O blade. If both channel zoning and host mapping are
enabled, the channel zoning settings supersede any host LUN
mapping on the FC I/O blade.

•

After configuring channel zoning, save the library configuration.
For instructions on how to save the library configuration, see
Saving and Restoring the Library Configuration on page 488.

112

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > FC I/O Blades > Channel Zoning.
• From the operator panel, select Setup > FC I/O Blades > Channel
Zoning.

Managing FC Hosts and
Host Mapping
3

An FC host is the main processing server on a storage area network
(SAN) that receives data and initiates communication with other devices.
When FC I/O blades are installed in the library, administrators can
access, add, modify, and delete FC hosts and also configure FC host
mapping. Before you can perform any of these FC host management
operations, you need to enable host mapping, which is disabled by
default. See Enabling/Disabling FC Host Mapping on page 113.
Note:

On the operator panel, the host management screens (Setup >
I/O Blades > Host Management) are not available unless FC host
mapping is enabled.

Note:

Enabling/Disabling FC
Host Mapping

Scalar i500 User’s Guide

3

If both channel zoning and host mapping are enabled, the
channel zoning settings supersede any host LUN mapping on
the I/O blade.

Administrators can enable or disable the optional FC host mapping
feature. This feature is disabled by default. When host mapping is
enabled, you can add, modify, and delete hosts as well as configure FC
host mapping.

113

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

The paths to open the appropriate screens are as follows:
• From the Web client select Setup > FC I/O Blades > FC I/O Blade
Control.
• From the operator panel, select Setup > I/O Blades > Blade Control.

Viewing FC Host
Information

3

The following information is provided for FC hosts:
• Host Name — The host device name
• I/O Blade — The location of the FC I/O blade in the library
• Status — The online/offine (connectivity) status of the host (Web
client only)
• Host Port — The host port number
• WWPN — The World Wide Port Name of the host device
• Type — The operating system of the host device
The paths to open the appropriate screens are as follows:
• From the operator panel, select Setup > FC I/O Blades > Host
Management.
• From the Web client, select Setup >FC I/O Blades > Host Management.

Creating, Modifying, and
Deleting an FC Host
Connection
3

Scalar i500 User’s Guide

Administrators can manually create a connection to an FC host if the host
was not already connected to the library when it was turned on. You can
also modify and delete an existing FC host connection. You can perform
these operations without down the library. You can add up to 32 FC host
connections per FC I/O blade.

114

Chapter 3 Configuring Your Library
Working With FC I/O Blades

After creating, modifying, or deleting an FC host connection, save the
library configuration. For instructions on how to save the library
configuration, see Saving and Restoring the Library Configuration on
page 488.

Note:

These operations should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

3

Creating an FC Host Connection

For each FC host connection you want to create, you can set the following
parameters:
• Host Name — The host device name.
• Host Port — The host port number.
• WWPN — The World Wide Port Name of the host device. The WWPN
text box is limited to 17 lowercase alphanumeric characters and
colons (:). The WWPN must be typed in the following format:
12345678:0b33ef12.
• Type — The appropriate host operating system.
• I/O blades — Lists the I/O blades you can select for the host.

3

Modifying an FC Host Connection
For each FC host connection you want to modify, you can set the
following parameters:
• Host Name — The host device name.
• Host Port — The host port number.
• Type — The appropriate host operating system.
You cannot modify the WWPN. If you want to change the WWPN, you
must delete and re-create the FC host connection.

Scalar i500 User’s Guide

115

Chapter 3 Configuring Your Library
Working With FC I/O Blades

3

Deleting an FC Host Connection
Administrators can delete connections to FC hosts without powering
down the system. Before deleting an FC host connection, make sure the
FC host is disconnected (offline) from the I/O blade.

A message will appear if the FC host is online when you attempt to delete
it. To continue, take the FC host offline or disconnect the FC host from the
I/O blade, wait for the FC host to go offline, and then continue to delete
the FC host connection.
Note:

If the host application is connected through an FC switch, a
power cycle of the I/O blade might be required to make the
host go offline. For instructions on how to power cycle an I/O
blade, see Controlling FC I/O Blade Power on page 263.

The paths to open the appropriate screens are as follows:
• From the operator panel, select Setup > I/O Blades > Host Management.
• From the Web client, select Setup > I/O Blades > Host Management.

Host Mapping - Overview 3

Host mapping enables you to manually modify host information and set
logical unit number (LUN) mappings, and to map specific hosts to library
LUN devices.
I/O blades discover target devices that are attached to ports 3–6, as well
as their internal virtual port (see FC I/O Blade Internal Virtual Port for
Media Changers on page 111). Each of these devices has its own native
logical unit number (LUN) that is used to address the device via the port
to which it is attached. These LUNs can be re-mapped to new LUNs for
presentation via ports 1 and 2. Further, custom LUN maps can be
simultaneously defined for individual hosts.
For example, the FC I/O blade may discover tape drives attached to ports
3–6, each of which report themselves at LUN 0. The FC I/O blade could
be configured to re-map these to LUNs 1, 2, 3, and 4 for discovery on
ports 1 and 2. If desired, they could also be simultaneously mapped to
LUNs 3, 5, 7 and 9 for a specific host server.
There is also an internal (i.e., not attached to a port) controller device
presented at LUN 0 by default. The controller device facilitates
initialization and device discovery. In some instances it may be useful to

Scalar i500 User’s Guide

116

Chapter 3 Configuring Your Library
Working With FC I/O Blades

map the controller device to a different LUN if an application typically
expects to see a media changer device (partition) or tape drive at LUN 0.
LUNs can also be mapped to be accessible by specific host server World
Wide Port Name (WWPN). Mapping a LUN to a specific WWPN can be
used instead of channel zoning to control device visibility. Mapping a
LUN to more than one WWPN may be useful for creating redundant
paths to a media changer device (partition), tape drive, or controller
device. LUNs will need to be mapped to each WWPN for host servers
that use multiple ports (e.g., multi-ported HBAs or multiple HBAs) if
access is desired via all the host server ports (e.g., a LUN would need to
be mapped to both WWPNs of a server that uses a dual-port HBA).
LUN masking is a complementary concept to host mapping in that LUNs
that are mapped to specific host server WWPNs are hidden (i.e., masked)
from other host servers. This is useful when more than one host server is
attached to the FC I/O blade (e.g., in a SAN). One or more of the LUNs
can be masked from discovery by specific host servers while maintaining
their mapping and accessibility to other host servers via the same port(s).

Host Mapping Vs.
Channel Zoning

3

Channel zoning places an operational restriction on mapped LUNs (for
example, if port 1 is zoned to ports 3 and 4, but LUNs from ports 3
through 6 have been mapped to a specific host server WWPN, the devices
on ports 5 and 6 cannot be accessed from that host via port 1, even though
they are mapped to it; only the devices on ports 3 and 4 would be
accessible from the host via port 1).
Host mapping can be used to control visibility of the media changer
devices (partitions) found on the FC I/O blade internal virtual port, while
channel zoning can be used to create simple access control to the other
target devices. If the host mapping capabilities are used to control
visibility and access for all the LUNs, channel zoning might not be
necessary or desired.
Note:

On the operator panel, the host mapping screens (Setup > FC
I/O Blades > Host Mapping) are not available unless FC host
mapping is enabled. See Enabling/Disabling FC Host
Mapping on page 113.

Scalar i500 User’s Guide

117

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Configuring Host
Mapping

3

To configure host mapping, you need to select the media changer device
(partition) or tape drive you want to map and assign a new LUN number
for the device.
Note:

Depending on host operating system constraints, it might be
necessary to reboot or reconfigure the host due to device
mapping changes that result from configuring host mapping.

Details on configuring host mapping include:
• Host mapping is an optional feature and is disabled by default. For
instructions on how to enable or disable host mapping, see
Enabling/Disabling FC Host Mapping on page 113.
• The Setup - I/O Blade Host Mapping screen on the Web client lists the
host name, I/O blade location, World Wide Port Name (WWPN), and
operating system type of each available FC host. You can select the
FC host to configure and proceed to the next screen.
The screen lists the available partitions and tape drives connected to
the FC I/O blade to which the FC host is attached. For each available
partition and tape drive, the screen lists the following:
•

Description — For tape drives: Drive [location
coordinates][(associated partition)]. For partitions: the name
assigned to the partition during the partition creation process.

•

Type — Device type, for example, processor, media changer
(partition), tape drive.

•

Serial Number — Serial number of the partition or tape drive.

•

Vendor — Device manufacturer.

•

Product — Name of the device.

•

LUN — Current logical unit number (LUN) assignment. Assign a

new LUN number for the device.

Note:

Scalar i500 User’s Guide

The operator panel host mapping configuration screens
show less information about each device; however, you
still select the host and device(s) and configure the LUN
number(s(.)

118

Chapter 3 Configuring Your Library
Working With FC I/O Blades

• After configuring FC host mapping, save the library configuration.
For instructions on how to save the library configuration, see Saving
and Restoring the Library Configuration on page 488.
Note:

A warning message will display if the command and control
LUN (CCL) or another device is not mapped to LUN 0 (zero).
LUN 0 is typically occupied by the command and control LUN
(CCL), unless it has been manually mapped to another LUN.
Make sure at least one device is mapped to LUN 0.

Note:

If an FC switch is attached to an FC I/O blade target port, the
FC switch will appear in the Blade Host Management list as if
it were an FC host. Do not map library devices to an FC switch.
To avoid confusion, it is recommended that you modify the FC
switch host name and type using Blade Host Management. See
Modifying an FC Host Connection on page 115.

Note:

If both channel zoning and host mapping are enabled, the
channel zoning settings supersede any host LUN mapping on
the FC I/O blade. For information on channel zoning, see
Configuring FC I/O Blade Channel Zoning on page 111.

The paths to open the appropriate screens are as follows:
• From the operator panel, select Setup > FC I/O Blades > Host Mapping.
• From the Web client, select Setup > FC I/O Blades > Host Mapping.

Configuring FC Host Port
Failover
3

When FC I/O blades are installed in the library, administrators can
enable and configure the optional FC host port failover feature. This
feature is disabled by default.
You can configure the FC host port failover feature so that a “standby”
target port (1 or 2) on an I/O blade can assume the identity and LUN
mapping configuration of the designated “active” target port if the active
port fails. Host port failover enables the library to continue operations
without requiring you to reconfigure the host or the SAN.

Scalar i500 User’s Guide

119

Chapter 3 Configuring Your Library
Working With FC I/O Blades

To enable host port failover, you must configure target ports 1 and 2 on
the FC I/O blade as point-to-point connections (Setup > FC I/O Blades >
Port Configuration). FC I/O blade target ports 1 and 2 must be attached to
the same SAN fabric to provide host access. The primary active port is
used for host communications, while the passive standby port is kept
idle. In addition, channel zoning must be configured so that target ports 1
and 2 have access to all initiator ports (ports 3–6) (Setup > FC I/O Blades >
Channel Zoning). If these conditions are not met, an error message will
display when you attempt to enable host port failover.
Note:

The current feature implementation does not support
arbitrated loop or target/initiator mode.

Note:

Ports on the 4 Gb FC I/O blade used for failover must connect
to the same SAN fabric.

Note:

When both target ports on the FC I/O blade are attached to the
same SAN fabric, you may see duplicate media changer
devices (partitions) being reported. To stop this from
happening, you need to enable host port mapping and
configure host mapping. For more information, see
Configuring Host Mapping on page 118.

Note:

When Fibre Channel port 2 is selected to be the active port in a
host port failover configuration, the active port can switch to
the default setting, port 1, following a reboot. Reconfigure the
host port failover settings so that the intended port is the
active port.

For information on configuring FC I/O blade ports and channel zoning,
see Configuring FC I/O Blade Ports on page 110 and Configuring FC I/O
Blade Channel Zoning on page 111.
The library generates a Reliability, Availability, and Serviceability (RAS)
ticket when port failover occurs. Examine the ticket to determine the
reason for the failover. When the failed port is repaired, the port must be
re-enabled to make it available for host port failover as the standby or
active port. For more information, see Repairing and Enabling a Failed
Target Port on page 121.

Scalar i500 User’s Guide

120

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Details on configuring host port failover include:
• The Setup - Host Port Failover screen displays all the FC I/O blades
found in the library. FC I/O blades are listed by the following:
location in the library, WWNN (Web client only), and status/state.
You can select the FC I/O blade you want to configure for host port
failover and proceed to the next screen.
• To enable FC host port failover for the selected FC I/O blade, you can
select a check box to enable FC Host Port Failover. Clearing the check
box disables FC host port failover for the selected FC I/O blade.
• If you are enabling FC host port failover, select one target port on the
FC I/O blade as the Active Port. The selected target port becomes
active by default. The other target port will go on passive standby
until failover occurs.
• After enabling or disabling FC host port failover, save the library
configuration. For instructions on how to save the library
configuration, see Saving and Restoring the Library Configuration on
page 488.
Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

• The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > I/O Blades > Host Port Failover.
• From the operator panel, Setup > I/O Blades > Host Port Failover.

Repairing and Enabling a
Failed Target Port
3

After host port failover occurs, the failed target port must be repaired and
enabled before it can be configured as an active or standby port for the
host port failover feature. To repair the failed port, use the information in
the RAS ticket that was generated when the host port failover occurred.
For information on viewing and resolving RAS tickets, see About RAS
Tickets on page 481.
Once the port has been repaired, you can enable it. Details on enabling a
repaired target port include:

Scalar i500 User’s Guide

121

Chapter 3 Configuring Your Library
Working With FC I/O Blades

• The Setup - Host Port Failover screen displays all the I/O blades
found in the library. I/O blades are listed by the following: location
in the library, WWNN (Web client only), and status/state. You can
select the I/O blade that had a failed target port and proceed to the
next screen.
• In the Physical Ports section of the Web client screen, check the State,
Failure Type, and Intervention columns for the port that failed.
Note:

If you are using the operator panel user interface, select
the Port Info button to view the physical ports
information.

• If the link is down or has an error, the port’s state is offline, a failure
type is indicated, and the Intervention is “Fix Link.” You must repair
the failed port using information in the RAS ticket that was generated
for the host port failover. You can then return to this screen and
enable the repaired port.
• After you fix the problem, the Intervention is “Enable Failover” and
the Enable button becomes available. Click Enable to make the port
available for another failover or for reconfiguration as the active port.
• Once the error is corrected and the link is enabled, the port’s state is
online and the Intervention is “Not Required.”
• After enabling the repaired target port, save the library configuration.
For instructions on how to save the library configuration, see Saving
and Restoring the Library Configuration on page 488.
Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

For information on how to configure the repaired port as the standby or
active target port, see Configuring FC Host Port Failover on page 119.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > I/O Blades > Host Port Failover.
• From the operator panel, Setup > I/O Blades > Host Port Failover.

Scalar i500 User’s Guide

122

Chapter 3 Configuring Your Library
Working With FC I/O Blades

Working With Data Path
Conditioning
3

When I/O blades are installed, administrators can configure data path
conditioning, an automatic means of verifying, monitoring, and
protecting data path integrity between FC I/O blades and FC tape drives.
Data path conditioning allows you to proactively detect and resolve data
path problems before they affect backup, restore, and other data transfer
operations.
The I/O blade does not manage data path conditioning along the path
between the host and the I/O blade. It does manage data path
conditioning along the path between itself and the FC tape drives. Data
path monitoring automatically occurs at regular, configurable intervals.
The I/O blade generates a RAS ticket if the monitoring tests fail for two
intervals.
To configure data path conditioning, set the following parameters for the
selected I/O blade:
• The level at which the data path is monitored between an I/O blade
and the FC tape drives connected to it. The two levels are as follows:
•

Interface Test — performs tests to verify that FC controllers on
I/O blades are responsive to commands. This is the default level.

•

Device Datapath Test — performs tests at the Interface Test level

and also performs a device inquiry on each target device.

• Test Interval — the time interval between monitoring checks. You can
configure the test interval. It can range from 5 to 2,880 minutes (48
hours). If you do not configure the test interval, the default test
interval is 60 minutes. If you disable data path conditioning and then
re-enable it in the future, the interval reverts to the default of 60
minutes regardless of whether you changed the interval previously.
Note:

Scalar i500 User’s Guide

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

123

Chapter 3 Configuring Your Library
Configuring Library Security Settings

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > I/O Blades > Data Path
Conditioning.
• From the operator panel, select Setup > I/O Blades > Data Path
Conditioning.

Configuring Library Security Settings
Administrators can use the operator panel Security Settings screen to
change the following security features:
• Network Interface — Enables external access to the library over
Ethernet. This setting is enabled by default to allow external access.
• SSH Services — Opens port 22 to allow Secure Shell (SSH) services,
to access the library. This setting is enabled by default.
• ICMP — Enables external attempts to discover the library by pinging
it (by means of the Internet Control Message Protocol [ICMP] Echo
packets). This setting is enabled by default.
• Remote UI —Opens port 80 to allow remote access to the library via
the Web client. This setting is enabled by default.
• SNMP — Opens port 161 to allow SNMP communication to the
library. This setting is enabled by default.
Note:

This setting differs from enabling SNMP services in the

Tools > System Settings menu (see Enable SNMP V1/V2

on page 129). In order to run SNMP, the port must be open
and the SNMP services must be enabled.
• SMI-S — Opens port 5988 to allow SMI-S communication to the
library. This setting is enabled by default.

Scalar i500 User’s Guide

124

Chapter 3 Configuring Your Library
Configuring the Internal Network

Note:

This setting differs from enabling the SMI-S service in the
Tools > System Settings menu (see Enable SMI-S on
page 129). In order to run SMI-S, the port must be open
and the SMI-S service must be enabled.

You cannot configure the security settings from the Web client. The path
to open the appropriate screen is as follows:
• From the operator panel, select Tools > Security.

Configuring the Internal Network
Use the Internal Network Configuration screen to configure your library’s
internal network setting. The default internal network address is
10.10.10.X.
The library’s internal network enables communication among library
components. While rare, it is possible that the default addressing of the
internal network could conflict with your network, potentially causing
the library to become confused. When installing the library, make sure
that the external network setting is different from the internal network
setting on the library. If DHCP is enabled or you do not know what your
external network setting is, check with your network administrator.

Caution:

Do not change the library’s internal IP address during
backup/restore operations.

From the operator panel, administrators can change the setting of the
internal network using the Internal Network Configuration screen. Select
the new internal IP address from the list on the screen. You can select
from nine IP addresses.
The Internal Network Configuration screen is only accessible from the
operator panel. The path to open the appropriate screen is as follows:
• From the operator panel, select Tools > Internal Network.

Scalar i500 User’s Guide

125

Chapter 3 Configuring Your Library
Configuring System Settings

Configuring System Settings
This section describes the system-wide settings you can configure on the
library. Each setting is described in detail below.
Details on the system settings include:
• The only setting users with User privileges can configure is the Touch
screen audio setting.
• Administrators can configure all the system settings.
• All of the system settings are available on the operator panel. The
only settings available on the Web client are user session timeout and
unlabeled media detection.
The paths to open the appropriate screens are as follows:
• From the operator panel, select Tools > System Settings.
• From the Web client, select Setup > System Settings.

User Session Timeout
(minutes)

3

The library automatically logs out a user or administrator when the
library has detected no activity for a specified length of time. You can
adjust the user session timeout by entering a numeric value in the User
session timeout (minutes) text box. Valid user session timeout values are
15 minutes to 480 minutes. You can change this setting from either the
operator panel or the Web client. When you change the setting on the
operator panel, the Web client is updated at the same time, and vice
versa.
• Touch Screen Audio — Allows you to enable or disable the beep
sound that occurs each time you press a button on the operator panel.
The Touch screen audio setting is enabled by default.
• Unload Assist — Allows you to specify whether the library should
automatically eject cartridges from tape drives. When the setting is
enabled, the library will assist with tape drive unload operations in
the event that a tape drive is not unloaded by a host command. When
the setting is disabled, the library will not assist with tape drive
unload operations and reject a move request from a tape drive, if the
cartridge is not already unloaded. The Unload Assist setting is
enabled by default.

Scalar i500 User’s Guide

126

Chapter 3 Configuring Your Library
Configuring System Settings

The paths to open the appropriate screens are as follows:
• From the operator panel, select Tools > System Settings.From the
Web client, select Setup > System Settings.

Tape Drive Logical SN
Addressing

3

The library assigns a fixed logical serial number to each tape drive slot in
the library (whether it is occupied or not). When the Logical SN
Addressing setting is enabled, the library reports only the logical serial
number to the host instead of the tape drive’s physical serial number. If
the tape drive is later replaced by another tape drive in the same slot, the
logical serial number remains the same. From the host application’s
perspective, the replacement tape drive is the same as the original.
Logical SN Addressing is enabled by default.
When the Logical SN Addressing setting is disabled, the library reports
only the tape drive physical serial number to the host.
The library System Information Report shows both the logical and
physical serial numbers on installed tape drives for your convenience
(Reports > System Information).
Caution:

If you change the logical serial number addressing
setting, you must power cycle the library in order
for the change to take effect.

Caution:

Use caution with this feature, as it can be accessed
by both Admin and Service login users. Enabling
this feature in an existing installation will change
the presentation of the tape drive serial numbers
to the host computer and host applications. Some
host operating systems, and some application
software, will no longer see a tape drive if the
serial number changes (by use of this feature)
from a previously set host configuration. If this
happens, you will need to reconfigure the tape
drives in your backup application.

The path to open the appropriate screen is as follows:
• From the operator panel, select Setup > System Settings.

Scalar i500 User’s Guide

127

Chapter 3 Configuring Your Library
Configuring System Settings

Manual Cartridge
Assignment

3

Administrators can disable or enable manual cartridge assignment. When
manual cartridge assignment is enabled (the default setting), the Assign
I/E screen automatically appears on the operator panel once cartridges are
placed into the I/E station. The Assign I/E screen prompts the user to use
the operator panel to assign the cartridges to a specific partition or to the
System partition. The cartridges can then be used only by the assigned
partition.
For more information on manual cartridge assignment, see
Disabling/Enabling Manual Cartridge Assignment on page 77.
The path to open the appropriate screen is as follows:
• From the operator panel, select Setup > System Settings.

Disable Remote Service
User
3

For security purposes, prevents a service user from logging in to the
library remotely, from either the Web client or over the Ethernet service
port. The service user will still be able to log in to the library from the
operator panel interface. This option is disabled by default.
The path to open the appropriate screen is as follows:
• From the operator panel, select Setup > System Settings.

Enable SSL

3

Enables Secure Socket Layer (SSL) for secure data transmission between
the library and remote clients. This option is disabled by default.
The path to open the appropriate screen is as follows:
• From the operator panel, select Setup > System Settings.

Scalar i500 User’s Guide

128

Chapter 3 Configuring Your Library
Configuring System Settings

Enable SNMP V1/V2

Enable IPv6

3

3

Enables Simple Network Management Protocol (SNMP) V1 and V2c
services to run on the library. This option is disabled by default.
Note:

SNMP v3 is always enabled. For more information on
SNMP, see Configuring SNMP Settings on the Library on
page 63.

Note:

This setting differs from opening the SNMP port in the
Tools > Security menu (see Configuring Library Security
Settings on page 124). In order to run SNMP, the port must
be open and the SNMP service must be enabled.

Enables support for IPv6. This option is disabled by default.
The path to open the appropriate screen is as follows:
• From the operator panel, select Setup > System Settings.

Enable SMI-S

3

Enables the SMI-S service to run on the library. This setting is disabled by
default.
Note:

This setting differs from opening the SMI-S port in the
Tools > Security menu (see Configuring Library Security
Settings on page 124). In order to run SMI-S, the port must
be open and the SMI-S service must be enabled.

The path to open the appropriate screen is as follows:
• From the operator panel, select Setup > System Settings.

Unlabeled Media
Detection

3

At bootup and other times the library performs an inventory of all slots
and media. If a slot contains media with an unreadable barcode label (for
example, the label is missing, torn, or marked up), the scanner cannot
identify it, so the library normally reports the slot as empty.
With the Unlabeled Media Detection feature, you can configure the
library to detect and report which slots contain media with unreadable
barcodes. Since cartridges with unreadable barcodes will not work for

Scalar i500 User’s Guide

129

Chapter 3 Configuring Your Library
Configuring System Settings

some library functions, knowing which labels are bad enables you to
replace them with good ones as soon as possible.
When you enable Unlabeled Media Detection, the calibration sensor rescans slots identified as empty in the inventory to see if a cartridge is
physically in the slot. If so, the library reports the cartridge as having an
unreadable barcode.
Note:

The library always re-scans “empty” slots in the top and
bottom rows of the library, even if you don’t enable the
Unlabeled Media Detection feature. This is because
occasionally a small or poorly placed label cannot be read
by the barcode scanner in those two rows. The calibration
sensor re-scans the bottom row, and the picker physically
checks the top row because the calibration sensor cannot
reach it.
“Bottom row” here means the bottommost available row
as indicated in the library configuration report.

This feature is disabled by default. When enabled, the following occurs:
• The re-scan may take up to several minutes to complete.
• You can configure the library to re-scan only the I/E station slots that
were identified as empty, or all the slots in the library that were
identified as empty.
• The library configuration report indicates media with unreadable
barcodes by displaying a red triangle in the corner of the slot.
• The library user interface lists No_Label as the barcode for all
cartridges with unreadable labels.
• The library posts a RAS ticket (T143) when an unreadable barcode
label is detected. As long as that ticket remains open, no more T143
tickets will be issued, even if more unreadable barcode labels are
found.
• An unreadable barcode label is re-scanned every time the cartridge
moves to a new location to check if it is readable in the new location.
The paths to open the appropriate screens are as follows:
• From the operator panel, select Tools > System Settings.
• From the Web client, select Setup > System Settings.

Scalar i500 User’s Guide

130

Chapter 3 Configuring Your Library
Configuring System Settings

Auto-Ticket Closure

3

Configuring the Library
for FIPS
3

For information about this feature, see Closing RAS Tickets
Automatically on page 485.

To configure your library for FIPS, perform the following steps:
1 Upgrade library firmware to version 600G or later.
2 For all HP LTO-5 FC tape drives that you plan to enable for FIPS,
upgrade firmware to the latest version qualified with the Scalar i500
library (see the Scalar i500 Release Notes for qualified firmware levels).
3 Shut down the library.
4 Do one of the following:
If your library is...

Do this...

5U

Perform Cabling a 5U Library for Ethernet
Connectivity on page 460.

14U or larger

Perform Installing the Ethernet Expansion
Blade on page 461.

5 Power on the library.
6 Install Storage Networking and Encryption Key Management
licenses on the library, if they are not already installed.
7 Enable FIPS mode (see Enabling and Disabling FIPS Mode on HP
LTO-5 Tape Drives on page 131).

Enabling and Disabling
FIPS Mode on HP LTO-5
Tape Drives
3

To operate your HP LTO-5 Fibre Channel tape drives to be compliant
with FIPS, you must enable “FIPS mode.” FIPS mode is configured by
partition. You enable FIPS mode on a partition, which enables FIPS mode
on all of the tape drives in the partition.
To change FIPS mode for a partition:
1 On the library web client, select Setup > Encryption > Partition
Configuration.
The Setup - Encryption Partition Configuration page displays (see
Figure 16 on page 132).

Scalar i500 User’s Guide

131

Chapter 3 Configuring Your Library
Configuring System Settings

Change the Encryption Method of a partition to Enable Library
Managed.
2 Select the FIPS check box to enable FIPS mode for the partition. Clear
the FIPS check box to disable FIPS mode for the partition.
3 Click Apply.

Figure 16 Enabling FIPS Mode

Viewing FIPS Status on
the Library
3

There are three ways to view FIPS status on the library:
• The Partition Configuration screen (Setup > Encryption > Partition
Configuration) shows which partitions are enabled for FIPS. All tape
drives in FIPS partitions are enabled.
• The System Information Report (Reports > System Information)
contains a FIPS column in the Library Partitions section. The column
displays “Yes” if FIPS is enabled on the partition and “No” FIPS is
disabled.
• The tape drive information pop-up screen on the Library
Configuration Report (Reports > Library Configuration) contains a
FIPS Enabled item. This item only displays when the tape drive is an
HP LTO-5 Fibre Channel tape drive. The item displays “Yes” when
FIPS is enabled on the drive and “No” when FIPS is disabled.

Scalar i500 User’s Guide

132

Chapter 3 Configuring Your Library
Configuring Operator Panel Display Settings

Configuring Operator Panel Display Settings
You can use the operator panel Display Settings screen to adjust the
operator panel’s brightness and contrast settings. The current applied
settings appear on the screen. Adjust the brightness and contrast settings
by tapping the up and down arrows. The Defaults button sets the
brightness and contrast to the default settings.
You cannot configure the display settings from the Web client. The path
to open the appropriate screen is as follows:
• From the operator panel, select Tools > Display Settings.

Registering the Library
Registering the library activates the warranty. After completing the initial
setup of the library, choose Setup > Register Library on the Web client to
automatically register the library. The library uploads the information
you entered in the Setup - Contact Information screen (Setup >
Notifications > RAS > Contact). If you have not filled out the contact
information yet, you will receive a message with a link. Complete the
Setup - Contact Information screen, and then return to the Setup > Register
Library screen to complete registration.
You cannot register the library from the operator panel. The path to open
the appropriate screen is as follows:
• From the Web client, select Setup > Register Library.

Scalar i500 User’s Guide

133

Chapter 4

Advanced Reporting

4

Advanced Reporting is a licensable feature. You must have an Advanced
Reporting license installed on your library in order to use the features
described in this chapter. For more information on licensing, see
Obtaining and Installing a License Key on page 88.
Advanced Reporting provides the following reports that you can
configure, view, save, and e-mail:
• Drive Resource Utilization Report—Provides tape drive usage
information, showing you which tape drives are working at optimum
capacity and which are under-utilized. This can help you allocate
your tape drive resources properly.
• Media Integrity Analysis Report—Provides TapeAlert count for
various combinations of tape drives, tape cartridges, and TapeAlert
flags. This can help you determine if a problem is due to a specific
tape drive or tape cartridge.
Advanced Reporting provides the following logs that you can view, save,
and e-mail:
•
•

Media Security Log — Lists media that has been removed from the

library.

Media Usage Log — Lists information on all media that have ever
been in the library.

In addition, you can automatically e-mail any of the reports and logs to
designated recipients at specified, scheduled times.

Scalar i500 User’s Guide

134

Chapter 4 Advanced Reporting
About the Advanced Reporting License

Note:

To use all the features of Advanced Reporting, your library
firmware must be at version 580G or higher.

This chapter covers:
• About the Advanced Reporting License
• Working With Advanced Reporting Reports
•

Configuring the Drive Resource Utilization Report

•

Configuring the Media Integrity Analysis Report

•

Using Advanced Reporting Templates

•

Loading and Reloading Advanced Reporting Data

•

Deleting Advanced Reporting Data

•

Saving and E-mailing Report Data Files

• Configuring and Viewing the Media Security Log
• Viewing the Media Usage Log
• Automatically E-mailing Advanced Reporting Reports and Logs

About the Advanced Reporting License
The Advanced Reporting license applies to your entire library, regardless
of library size. This means you only need to purchase the license once. If
you increase the size of your library, your existing license applies to your
new library configuration.

Scalar i500 User’s Guide

135

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

Working With Advanced Reporting Reports
Details about Advanced Reporting reports include:
• The data for the reports is collected in log files. When the log files
reach their maximum size, the oldest information is deleted as new
information is added. This may affect how much historical data you
can access.
• The on-screen reports contain a chart and a data table. When the log
files are large, it would take an excessively long time to load all the
historical data into the data table. For this reason, the table displays a
maximum of 1000 rows of data, beginning with the most recent, even
if more data is available. (The graph displays information for the
entire range.) To view all of the data, you need to save or e-mail the
data file. See Saving and E-mailing Report Data Files on page 142.
• The reports are built according to data in the log files, not your
current library configuration. For this reason, your library may
contain tape drives or cartridges that do not show up in the report.
Similarly, the report may contain tape drives and cartridges that no
longer reside in the library.
• Information about a tape drive, cartridge, or operation is not
recorded in the Drive Resource Utilization log file until after a tape
cartridge has been mounted (loaded) and unmounted (unloaded)
from the tape drive.

Configuring the Drive
Resource Utilization
Report

4

This report identifies how tape drive resources are utilized in your
library. You can use this report to help you determine the proper work
load distribution between the tape drives in your library.
The following information is collected for each tape drive installed in the
library:
• Drive location (module, row)
• Drive serial number
• Partition
• Megabytes read
• Megabytes written

Scalar i500 User’s Guide

136

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

• Time and date of mount (UTC)
• Time and date of dismount (UTC)
• Media motion time (in seconds)
• Tape cartridge barcode
To configure the report, specify the following:
• Date Range — Specifies the range of time covered in the report.
Choose one of the following:
•

Last 7 days

•

Last 4 weeks (default)

•

Last 3 months

•

All History (as far back as there is data in the log file)

• Attribute — Specifies which values are included in the report. Select
one of the following:
•

Data Written/Read (default) — The amount of data written to
and read from each tape drive, shown separately in the chart.

•

Total Read and Write — The combined total amount of data
written to and read from each tape drive.

•

Media Mount Count — The number of tape cartridge mounts.

•

Media Mount Time — The total amount of time media spent in
the selected drive(s).

•

Media Motion Time — The total amount of time media spent in
motion while in the tape drive (writing, reading, rewinding, etc.).

• Chart — How the data is displayed in the chart. Select Area, Bar
(default), Line, or Pie.
• Type — The chart type. Select one of the following:

Scalar i500 User’s Guide

•

Rollup (default) — Displays the Grouping on the x-axis and the
Attribute amount on the y-axis.

•

Trend — Shows how the Attribute amount changes over time for
the selected Grouping.

137

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

• Grouping — Specifies which tape drive(s) or partition(s) to include in
the report. Select one of the following:
•

All Drives by Coordinate (default) — Presents the sum total of
the selected Attribute for all tape drives according to their
location in the library. If more than one tape drive resided in that
location during the selected Date Range, then the Attribute
values for all the tape drives that resided in that location are
combined in the chart.

•

All Drives by Physical SN — Presents the sum total of the
selected attribute for all drives according to the physical tape
drive serial number.

•

All Partitions — Presents a comparison of all drives grouped by
partition in the physical library.

•

Selected Drive by Coordinate — The report chart is based on an
individual tape drive location in the library. If more than one
tape drive resided in that location during the selected Date
Range, then the attribute values for all the tape drives that
resided in that location are combined in the chart.

•

Selected Drive by Physical SN — The report chart is based on an
individual tape drive identified by its physical drive serial
number.

•

Selected Partition — The report chart is based on an individual
partition in the physical library.

You can only access this report from the Web client. The path to open the
report is Reports > Advanced Reporting > Drive Resource Utilization.

Configuring the Media
Integrity Analysis Report4

This report provides TapeAlert counts for various combinations of tape
drives, tape cartridges, and TapeAlert flags. You can use this report to
help determine if a problem is due to a specific tape drive or tape
cartridge.
The report displays the number of TapeAlerts for the selected Grouping
and combination of Attributes. Additionally, the downloaded report
includes the last 10 tape drive error codes for each TapeAlert, displayed
in columns with the headings Error #1, Error #2, and so on. (The onscreen
report does not contain the tape drive error codes.)

Scalar i500 User’s Guide

138

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

The Media Integrity Analysis report collects the following information for
each TapeAlert:
• Date and time (UTC) of TapeAlert occurrences
• Tape drive physical serial number
• Cartridge barcode
• TapeAlert value
• Occurrence count of each TapeAlert
• Tape drive error codes for each TapeAlert
To configure the report, specify the following:
• Date Range — Specifies the range of time covered in the report.
Choose one of the following:
•

Last 7 days

•

Last 4 weeks (default)

•

Last 3 months

•

All History (as far back as there is data in the log file)

• Attribute—Specifies which values are included in the report, and how
they are combined. Select in any combination, including all (default).
If you select no attributes, the report uses Cartridge Barcode.
•

Cartridge Barcode — All relevant tape cartridges.

•

Drive Physical SN — All relevant tape drives.

•

TapeAlert — All TapeAlert flags that were issued. For a
description of all TapeAlert flags, see Appendix B, TapeAlert
Flag Descriptions.

• Chart — Specifies how the data is displayed in the chart. Choose
Area, Bar (default), Line, or Pie.
• Type — Specifies the chart type. Select one of the following:

Scalar i500 User’s Guide

•

Rollup (default) — Displays the number of TapeAlerts for the
combination of Grouping and Attributes you selected (default).

•

Trend — Shows the occurrence of TapeAlerts over time.

139

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

• Grouping—Specifies which drive(s) or tape cartridge(s) on which to
base the report. Choose one of the following:
•

All (default) — All tape drives and tape cartridges for which a
TapeAlert was issued during the specified Date Range.

•

Selected Drive by Physical SN — An individual tape drive. Only
tape drives which issued a TapeAlert during the specified Date
Range appear in the report.

•

Selected Cartridge by Barcode — An individual tape cartridge.
Only tape cartridges that were associated with a TapeAlert
during the specified Date Range appear in the report.

• Sorting— Specifies how the data will be sorted. Choose from the
following:
•

Alphabetical

•

Count (ascending)

•

Last Occurrence (default)

You can only access this report from the Web client. The path to open the
report is Reports > Advanced Reporting > Media Integrity Analysis.

Using Advanced
Reporting Templates

4

If you want to use the same configuration repeatedly, you can save it as a
template. You can save up to 20 templates for each type of advanced
report.

4

Creating a Template
1 From the report configuration page, make the selections you want.

2 In the Report Templates box at the bottom of the screen, type a name
for the template in the empty field next to the Save button. The name
can have a maximum of 15 characters. You can use only lowercase
letters, numbers, and the underscore character (_) in template names.
3 Click Save.
The report appears in the drop-down list next to the Load button.

Scalar i500 User’s Guide

140

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

Using a Template

4

To use a saved template, select the template from the drop-down list and
click Load.
Deleting a Template

4

To delete a template, select the template from the drop-down list and
click Delete.

Loading and Reloading
When you first open an Advanced Report configuration page, the system
Advanced Reporting Data 4 loads all the data from the library log file for that report to the Internet
browser in preparation for creating your reports. If there is a lot of
information in the log files, this may take several minutes.
The data that is loaded in the Internet browser remains unchanged until
you log out of your library session or reload the data. If new data is
added to the library log file during your session (for instance, a TapeAlert
occurs), it will not appear in the onscreen report until you either log out
of the library and log on again, or reload the data. To reload the data
without logging out, click the Reload button. This reloads the entire data
set, which may again take several minutes.
You can see how many records were loaded from the log files for this
report by looking at the Report Data section of the report configuration
page. A note says “XX records read,” where XX is the number of records
(see Figure 17).

Deleting Advanced
Reporting Data

Scalar i500 User’s Guide

4

In some circumstances, you may wish to delete the information contained
in the log files used to build the advanced reports. To do this, click the
Delete button in the Report Data section of either report configuration
page. This deletes the data for both the Drive Resource Utilization report
and the Media Integrity Analysis report.

141

Chapter 4 Advanced Reporting
Working With Advanced Reporting Reports

Caution:

Once you delete the data in the log files, you cannot get it
back. The Reload button does NOT retrieve deleted data! It
is recommended that you save all the data for both the
Drive Resource Utilization report and the Media Integrity
Analysis report before deleting the data (see Saving and Emailing Report Data Files).

Figure 17 Report Data Buttons

Saving and E-mailing
Report Data Files

4

You cannot save the report as it appears on the screen, but you can save
or e-mail the report data as a comma-separated values (.csv) file. You can
then import the .csv data into a spreadsheet program and manipulate it to
create your own reports for analysis. The .csv file contains all of the data
in the log file that falls within the date range you specify.
1 Generate a report.
2 Scroll down to the bottom of the report viewing screen to a box titled
Retrieve the Report Data File.
3 To save the report data as a .csv file, click Save.

Note:

To e-mail a saved report from the Web client, you must save the report, and then go to
another page in the web client. Return to the report viewer page, scroll down to the
bottom of the report viewing screen to a box titled Retrieve the Report Data File, and click
E-mail.
4 To e-mail the report data as a .csv file, type the name of a recipient in
the empty field next to the E-mail button, then click E-mail.

Scalar i500 User’s Guide

142

Chapter 4 Advanced Reporting
Configuring and Viewing the Media Security Log

Figure 18 Saving and
E-mailing the Report Data

Configuring and Viewing the Media Security Log
Media removal is detected by the library when it performs an inventory
(at boot up; after an open door is closed, etc.). The media security log lists
media that have been removed from the library. You can enable the
library to collect information about media removal, and then view, save,
and/or e-mail the log.
You can configure the library to collect any or all of the following
information. By default, the library collects nothing and the log is empty.
You must select each item you want the library to collect:
•

Unexpected Removal Detection After Power-up and Reboot Only

•

Unexpected Removal Detection During Library Operation

•

Expected Removal Detection From I/E Slots During Library Operation

Note:

Unexpected removal refers to tape cartridges that were

removed from the library without being properly exported via
the I/E station.
Expected removal refers to tape cartridges that were exported
properly via the I/E station.
The log file contains the following information:
• Date and time of media removal
• Tape cartridge barcode
• Type of removal (expected or unexpected)
• Slot location coordinates (of the slot the cartridge is missing from)
• Slot type (I/E, storage, or cleaning)

Scalar i500 User’s Guide

143

Chapter 4 Advanced Reporting
Viewing the Media Usage Log

When the log file reaches its maximum size, the oldest information is
replaced as new information is added.
To configure what information gets tracked in the log, select Setup >
Notifications > Advanced Reporting > Media Security from the Web client.
To view, save, or e-mail the report, select Reports > Log Viewer from the
Web client. Select Media Security Log from the list of logs and click Next.

Viewing the Media Usage Log
The Media usage report lists information regarding data written and read
on the media and lists statistics pertaining to soft and hard read and write
errors.The media usage log collects information on all media that have
ever been in the library, including media that are no longer in the library.
Lifetime media usage metrics are associated with the cartridge and are
kept on the embedded cartridge memory. The log reflects what the drive
reports from the embedded cartridge memory whenever the media is
unloaded. If the tape cartridge was never mounted and unloaded, it will
not appear in the log. When the log file reaches its maximum size, old
information is deleted as new information is added. This may affect the
amount of available historical data.
The log provides the following information:

Scalar i500 User’s Guide

•

Volser — Media cartridge barcode label

•

SN — Media cartridge serial number

•

Mfr — Media cartridge manufacturer

•

Date — Media cartridge manufacturing date (format: YYYYMMDD)

•

Type — Media type

•

Mounts — Cartridge mount count

•

RRE — Recovered read errors

•

URE — Unrecovered read errors

•

RWE — Recovered write errors

•

UWE — Unrecovered write errors

144

Chapter 4 Advanced Reporting
Automatically E-mailing Advanced Reporting Reports and Logs

•

LW — Cartridge lifetime MB written

•

LR — Cartridge lifetime MB read

•

Enc — Cartridge encryption status (U=Unknown, E=Encrypted,
N=Not Encrypted)

To view, save, or e-mail the report, select Reports > Log Viewer from the
Web client. Select Media Usage Log from the list of logs and click Next.

Automatically E-mailing Advanced Reporting Reports and
Logs
You can configure the library to automatically e-mail Advanced
Reporting logs and reports to specified recipients on a daily or weekly
basis.
You can create up to 20 e-mail recipients. If you want to send the same
recipient a different set of reports, you can enter the same e-mail address
more than once, with different reports selected for each. Each entry
counts as a unique recipient toward the 20 total.

Scalar i500 User’s Guide

145

Chapter 4 Advanced Reporting
Automatically E-mailing Advanced Reporting Reports and Logs

Note:

Duplicate entries are not allowed. A duplicate entry means the
same recipient is set to receive the exact same reports in two
different entries, regardless of the day or time. If you have
duplicate recipients, make sure that the reports selected in
each entry are not an exact match.
For example, if you have one entry in which Recipient A
receives the Drive Utilization and Media Integrity reports on
Monday, you cannot create another entry to send Recipient A
the Drive Utilization and Media Integrity reports on Thursday.
Instead, you can create one entry for Recipient A and send the
reports every day (select Daily as the day to send the report), or
you can change the reports you are sending so that they are
not the same as the first entry. You could create three entries
for Recipient A as follows: 1) send both reports out on
Monday; 2) send Drive Utilization out on Thursday; and 3)
send Media Integrity out on Thursday (in a different entry).
The recipient is the same, but the reports sent in each entry are
different.

Each e-mail notification includes an optional comment text box you can
use to enter information about the library or the reports and logs that you
want the recipient to know. This information appears in the body of the
e-mail.
You can modify the settings of an existing e-mail notification at any time
after it is created. If an e-mail notification is no longer needed, you can
delete it.
Before the library can send e-mail notifications, you must configure the
library e-mail account. For information on how to configure the e-mail
account, see Configuring the Library E-mail Account on page 92.
Administrators can configure the library e-mail account and e-mail
notifications. Users with user privileges can receive e-mail notifications,
but they cannot configure the library e-mail account or e-mail
notifications.
The path to open the appropriate screen is as follows:
• From the Web client, select Setup > Notifications > Advanced
Reporting > Receiver Addresses.

Scalar i500 User’s Guide

146

Chapter 5

5

Capacity on Demand

All Scalar i500 library configurations ship with the purchased number of
slots pre-activated. The number of available pre-activated slots begins at
41 for all library configurations and increases in 46-slot increments to a
maximum of 409 slots in the 41U library configuration.
After the initial purchase of your library, you can activate any remaining
inactive slots in your library by purchasing a COD license upgrade.
Upgrades are sold in 46-slot increments. For example, a 14U library could
have 87 slots licensed at the time of the initial purchase (41 default + 46
purchased = 87). The remaining 46 slots of the 14U library can be
activated at a later time by purchasing an upgrade. The full 133 slots
would then be available for use.
If you upgrade to more slots, your new license key contains the entire
license corresponding to your expanded slot count. The new license key
replaces your current license key. For more information on licensing, see
Obtaining and Installing a License Key on page 88.
It is possible to license more slots than are physically available in the
library. In that case, when expansion modules are added, the extra
licensed slots then become available for use.
To see your library’s current configuration and slot availability, open the
Library Configuration Report (choose Reports > Library Configuration
from the Web client).
Table 6 shows the number of default and available pre-activated slots
available for purchase and the number of slots you can activate with a
COD license key for each library configuration.

Scalar i500 User’s Guide

147

Chapter 5 Capacity on Demand

Table 6 Available Slots and
COD Upgrades Per
Configuration

5U

14U

23U

32U

41U

Minimum,
Maximum
Available Slots
(including I/E
station slots)

41, 41

41, 133

41, 225

41, 317

41, 409

Default
Pre-Activated
Slots

41

41

41

41

41

Available
Pre-Activated
Slots

41

41, 87, 133

41, 87,
133, 179, 225

41, 87, 133,
179, 225, 271,
317

41, 87, 133,
179, 225, 271,
317, 363, 409

Available
COD Slot
Upgrades

NA

87, 133

87, 133,
179, 225

87, 133, 179,
225, 271, 317

87, 133, 179,
225, 271, 317,
363, 409

Scalar i500 User’s Guide

148

Chapter 6

6

Storage Networking

Storage Networking (SNW) is a licensable feature that allows you to take
advantage of the control path failover, data path failover, and host access
configuration features of 8 Gb/s HP LTO-5 FC tape drives, without those
drives being connected to a 4 Gb/s FC I/O blade. (Since the FC I/O
blade has a maximum speed of 4 Gb/s, you can only get the full speed by
NOT being connected to the FC I/O blade.)
The SNW license is also required for FIPS compliance. For more
information on FIPS, see FIPS-Certified Encryption Solution on page 199.
This chapter covers:
• About the Storage Networking License
• Configuring Control Path Failover
•

Forcing Control Path Failover

• Configuring Data Path Failover
•

Enabling Data Path Failover

•

Forcing Data Path Failover

• Configuring Host Access

Scalar i500 User’s Guide

•

Registering a Host for Host Access

•

Enabling Tape Drives for Host Access

•

Mapping a Host to Tape Drives and Partitions

•

Modifying a Host

•

Deleting a Host
149

Chapter 6 Storage Networking
About the Storage Networking License

About the Storage Networking License
If you purchase a Storage Networking (SNW) license after you purchase
your library, you must install the license key on your library to enable the
SNW functionality.
The SNW license is sold on a per-drive basis. The license installed on the
library indicates the number of tape drives that are licensed.
If you purchase an SNW license for a particular number of tape drives
and later want to license more drives, you must purchase additional
SNW licenses.
The licenses are not tied to specific tape drives, but to how many tape
drives are currently using SNW features. If you remove all SNW features
from a tape drive, then the license becomes available to use on another
tape drive.
For more information on licensing, see Obtaining and Installing a License
Key on page 88.

Configuring Control Path Failover
If an HP LTO-5 FC tape drive is the control path for a partition, you can
select another HP LTO-5 FC tape drive in that partition for control path
failover. This means that if the control path tape drive fails, the failover
tape drive becomes the control path for the partition. The failed-over tape
drive remains the control path for the partition unless it fails or the
library is restarted. When either of these events occurs, the library starts
over and attempts to use the original control path tape drive as the
control path, and the original failover tape drive for failover.
Details about control path failover include:
• The SNW license must be sufficient to cover both the control path
and failover tape drives in order to enable a tape drive for failover.
• The control path and failover tape drives must both be HP LTO-5
Fibre Channel tape drives.

Scalar i500 User’s Guide

150

Chapter 6 Storage Networking
Configuring Control Path Failover

• Both the control path and failover tape drives must have their
topology configured as Point to Point (see Setting Tape Drive
Parameters on page 83). Previously, the library allowed you to
change the topology once control path failover was configured,
even though this prevented the feature from working. Now, the
library will not enable control path failover unless both the control
path and failover tape drives are configured as Point to Point, and
will not allow you to change the topology from Point to Point on
any tape drives configured for control path failover.
• The control path and failover tape drives must be connected to an
NPIV-enabled switch on the same fabric. They must not be connected
to an FC I/O blade.
• The control path and failover tape drives are assigned by location in
the library, so even if you replace a tape drive, the library will still fail
over or revert to the specified location.
• When control path failover is configured for a partition, the partition
uses a virtual port as the control path communication port. The
World Wide Port Name (WWPN) for this virtual port is listed in the
library’s System Information Report in the Library Partitions section
under Control Path (see Viewing the System Information Report on
page 267).
• A tape drive can be configured for both control path failover and data
path failover (see Configuring Data Path Failover on page 154).
• You can manually force a failover (see Forcing Control Path Failover
on page 151).
You can only configure control path failover from the Web client. The
path to open the appropriate screen is:
• From the Web client, select Setup > Control Path.

Forcing Control Path
Failover

6

You can manually force a control path failover. You might want to force a
failover to check that the non-active tape drive still works, or to switch
back to the original control path tape drive once the issue that originally
caused the failover has been fixed.
To force a control path failover:
1 From the Web client, click Tools > Drive Operations.
The Tools - Drive Operations screen displays (see Figure 19).

Scalar i500 User’s Guide

151

Chapter 6 Storage Networking
Configuring Control Path Failover

Figure 19 Forcing Control Path
Failover

2 Select Force Control Path Failover and click Next.
The Force Control Path Failover screenu displays (see Figure 20). All
of the partitions that have control path failover enabled are listed.
The location and status of the tape drive that is currently serving as
the control path are listed in the Active columns. The location and
status of the tape drive that is currently serving as the standby
control path are listed in the Standby columns. For each partition, the
following information is listed:

Scalar i500 User’s Guide

Column

Indicates

Active Drive

Location of the current control path tape
drive.

Active Status

Ready status of the current control path tape
drive.

Active Connected

Whether the current control path tape drive
is connected and has a working link.

152

Chapter 6 Storage Networking
Configuring Control Path Failover

Column

Indicates

Standby Drive

Location of the standby tape drive.

Standby Status

Ready status of the standby tape drive.

Standby Connected

Whether the standby tape drive is connected
and has a working link.

Figure 20 Forcing Control Path
Failover

3 Select the partition on which you want to force the failover.
Note:

The standby tape drive must be “ready” and “connected”
in order to force a failover.

4 Click Apply.
The new active tape drive location displays in the Active Drive
column. The new standby tape drive location displays in the Standby
Drive column.
Note:

Scalar i500 User’s Guide

If the new tape drive locations do not display, refresh the
browser.

153

Chapter 6 Storage Networking
Configuring Data Path Failover

Configuring Data Path Failover
Data Path Failover provides an alternate data path when a preferred data
path fails. The Data Path Failover functionality is provided as part of the
Storage Networking license and applies to HP LTO-5 Fibre Channel tape
drives only.
HP LTO-5 Fibre Channel tape drives have two Fibre Channel ports. If you
enable data path failover on the tape drive, one port will be used as the
“active port” for data transmission, and the other port will stand by to be
used if the active port fails. If the tape drive loses its Fibre Channel link
with the active port, it will automatically “fail over” and use the standby
port to continue drive operations. The library issues a RAS ticket when
automatic failover occurs. In addition, the library monitors the standby
port and issues a RAS ticket if the standby port does not report a good
Fibre Channel link status.
The library uses Port 1 for data path transmission unless a failover occurs.
Once failover occurs, the library uses Port 2 until failover occurs again or
the library is rebooted. Similarly, if a tape drive configured for data path
failover is the control path for a partition, the host uses Port 1 for media
changer commands unless a failover occurs. Once failover occurs, the
host uses Port 2 until failover occurs again or the library is rebooted.
Note:

Performing a drive reset operation is another way to make
Port 1 the active port again, unless the reason Port 2 is active is
due to a forced failover (see Forcing Data Path Failover on
page 157). If you forced a failover to Port 2 and then reset the
tape drive, the library and host will continue to use Port 2 until
failover occurs again or the library is rebooted.

A tape drive can be configured for both data path failover and control
path failover. If both are configured, the control path will not fail over to
another tape drive unless both ports on the control path tape drive fail.
If desired, you can manually switch the active port (see Forcing Data Path
Failover on page 157).

Scalar i500 User’s Guide

154

Chapter 6 Storage Networking
Configuring Data Path Failover

Note:

If you are NOT using data path failover on a tape drive, then
only Port 1 is used for data path or control path transmission.
The library and host will not recognize Port 2 unless data path
failover is enabled on the tape drive.

Details about data path failover include:
• The tape drives must be HP LTO-5 Fibre Channel tape drives.
• HP LTO-5 FC tape drive firmware must be at the version qualified
with the Scalar i500 library (see the Scalar i500 Release Notes for
qualified firmware levels).
• The library must have a Storage Networking license sufficient to
cover the tape drive(s) on which you want to configure data path
failover.
• Both FC ports on the tape drive must be connected to a host or
switch. Neither tape drive port may be connected to a Fibre Channel
I/O blade.
• Data path failover must be enabled on the tape drives (data path
failover is disabled by default).
• Tape drive topology settings must be set to Point to Point.

Enabling Data Path
Failover

Scalar i500 User’s Guide

6

To enable data path failover:
1 Connect both tape drive Fibre Channel ports (Port 1 and Port 2) to a
host or switch (see Figure 21).

155

Chapter 6 Storage Networking
Configuring Data Path Failover

Figure 21 HP LTO-5 Fibre
Channel Tape Drive Ports
Port 1 Status LED

Port 1 – default
data path

Port 2 Status LED

Port 2 – default
failover port

2 From the library Setup menu, click Drive Settings.
The Setup - Drive Settings page displays (see Figure 22).
3 For each tape drive on which you want to enable data path failover,
do the following:
a First, change the Requested Topology setting to Point to Point.
b Then select the DPF check box.
4 Click Apply.

Scalar i500 User’s Guide

156

Chapter 6 Storage Networking
Configuring Data Path Failover

Note:

The illustration shows Port 1 as the default data port and Port
2 as the default failover port, but these defaults apply only if
the data path failover feature is not enabled when you insert
cables.
If data path failover is enabled, the first port into which you
insert a cable becomes the active data port and the second
port becomes the failover port. For example, if data path
failover is enabled and you insert a cable into Port 2, that
port becomes the active data port. Inserting a cable into Port
1 makes that the port used for data path failover.

Figure 22 Enabling Data Path
Failover

Forcing Data Path
Failover

Scalar i500 User’s Guide

6

You can manually swich the active Fibre Channel port on a DPF-enabled
tape drive by forcing a failover. You might want to force a failover to
check that the non-enabled port still works, or to switch back to using
Port 1 once the issue that originally caused it to fail over is fixed.

157

Chapter 6 Storage Networking
Configuring Data Path Failover

You can only force a failover on one tape drive at a time. Both Fibre
Channel ports must be connected to a host or switch.
You can only force a failover from the Web client.
To force a data path failover:
1 From the Tools menu, click Drive Operations.
The Tools - Drive Operations screen displays (see Figure 23).

Figure 23 Forcing Data Path
Failover

2 Select Force Data Path Failover and click Next.
The Force Data Path Failover page displays (see Figure 24). All of the
tape drives that have data path failover enabled are listed. The port
currently being used as the data path is listed in the Active Port
column. The Active Port column will state “No Link” if neither port is
connected.

Scalar i500 User’s Guide

158

Chapter 6 Storage Networking
Configuring Data Path Failover

Figure 24 Forcing Data Path
Failover

3 Select the tape drive on which you want to force the failover.
Note:

The tape drive must be in the “ready” state in order to be
selected.

4 Click Apply.
The new active port displays in the Active Port column.

Scalar i500 User’s Guide

Note:

If the new active port does not display, refresh the page in
the browser.

Note:

The library will issue a RAS ticket if the forced failover
fails. The library will not issue a RAS ticket if the forced
failover succeeds.

159

Chapter 6 Storage Networking
Configuring Host Access

Configuring Host Access
Host Access provides a way to limit host access to specific tape drives
and partitions via the library interface.
To use host access, you must have a Storage Networking license on the
library. The Storage Networking license must be sufficient to cover the
tape drive(s) you want to configure for host access.
To configure host access, you must first register the host(s) for host
access, and enable host access on the desired tape drive(s). Then you will
map the host to the tape drives or partitions you want the host to access.
Details about host access include:
• A registered host has full access to all tape drives in the library that
have not been enabled for host access, and full access to all tape
drives that are enabled for host access and have been mapped to that
host. A registered host has no access to drives that have been enabled
for host access but are not mapped to that host.
• An unregistered host has full access to all tape drives in the library
that have not been enabled for host access, but no access to tape
drives that have been enabled for host access.
• Tape drives that are enabled for host access can only be accessed by
registered hosts that are mapped to them.
• Tape drives that are not enabled for host access can be accessed by all
hosts.
• If the control path and any failover tape drives for a partition are
enabled for host access, then only the hosts mapped to that partition
will be able to send media changer commands to that partition.
Unregistered hosts and registered hosts not mapped to that partition
will not be able to send media changer commands to that partition.
However, unregistered hosts and registered hosts that are not
mapped to that partition do still have access and can send commands
to any non-host-access-enabled tape drives in the partition, as well as
any host-access-enabled tape drives in the partition to which they are
mapped.

Scalar i500 User’s Guide

160

Chapter 6 Storage Networking
Configuring Host Access

• A maximum of 64 host entries can be mapped for access control to
each tape drive, regardless of whether the hosts are mapped to the
tape drive, to the partition for which the drive provides the library
control path, or both. If the same host is mapped to both the tape
drive and the partition, the same host consumes two host entries.
You can only configure host access control from the Web client. The
menu paths are:
• Setup > Host Access > Host Registration and
• Setup > Host Access > Host Connections

Registering a Host for
Host Access

6

There are two ways to register a host: using the Create and Add buttons.

6

Create
Create allows you to manually create and register a host by entering the

host information.

1 From the Web client, select Setup > Host Access > Host Registration.
2 Click Create.
3 Enter a user-defined host name.
4 Enter the host WWPN.
5 Select the host type from the pull-down list.
6 Click Apply.
The host appears in the list of registered hosts on the Setup - Host

Registration screen.

6

Add

Add allows you to choose a host for registration from a list of unregistered

hosts.

1 From the Web client, select Setup > Host Access > Host Registration.
2 Click Add.
The library displays a list of all currently unregistered hosts that are
connected to tape drives or FC I/O blades in the library.

Scalar i500 User’s Guide

161

Chapter 6 Storage Networking
Configuring Host Access

3 Select a host and click Add (you can only add one host at a time).
4 Under Add a Host, enter or modify the host name in the Name field
and select the host type from the Select Type drop-down list.
5 Click Apply.
This registers the host. The page reloads so you are now viewing the
Registered Hosts list on the Setup - Host Registration screen. The host
you just added appears on the Registered Hosts list (and no longer
appears on the Unregistered Hosts list).
6 If you need to register more hosts from the Unregistered Hosts list,
click Add again to see the list of unregistered hosts, and proceed from
Step 4.

Enabling Tape Drives for
Host Access
6

Tape drives must be enabled for host access before you can map hosts to
them.
1 Navigate to Setup > Host Access > Host Connections, or click the
Access button from the Setup - Host Registration screen.
The Setup - Host Connections screen appears, displaying a list of all
tape drives that can be enabled for host access.
2 Select the Access Control check box of all tape drives you want to
enable for host access.
3 Clear the Access Control check box of any tape drives you do not
want to enable for host access.

Note:

If you disable a tape drive that was previously enabled
and mapped to hosts, the tape drive can be accessed by all
hosts. However, the library keeps track of the mapped
connections, so that if you re-enable the tape drive later,
the connections you had before are reinstated.

4 Click Apply.
5 Click Next to go to the next screen to map hosts to tape drives and
partitions. (If the Next button does not appear on the screen, it means
no tape drives are enabled for host access.)

Scalar i500 User’s Guide

162

Chapter 6 Storage Networking
Configuring Host Access

Mapping a Host to Tape
Drives and Partitions
6

You must map one host at a time, and click Apply after configuring each
host.
1 Navigate to Setup > Host Access > Host Connections, or click the
Access button from the Setup - Host Registration screen.
2 Select drives to enable for host access (described in Enabling Tape
Drives for Host Access on page 162) and click Next.
The Setup - Connection Configuration screen appears, displaying two
or three sections of items to map, as follows:
•

Hosts — Displays all registered hosts.

•

Partitions — Partitions will only display if the control path tape

•

Devices — Displays all tape drives that are enabled for host

drive for the partition is enabled for host access. If the control
path tape drive has a failover tape drive associated with it, then
the failover tape drive must also be enabled for host access.
Mapping a partition to a host allows the host send media changer
commands to the partition through the control path tape drive.

access. Mapping a host to a tape drive gives the host access to the
tape drive.

3 Select a host.
The Partitions and Devices lists refresh showing the currently selected
partitions and drives mapped to that host.
4 Select the check boxes corresponding to partitions/drives to give the
host access; clear the check boxes to make the partitions/drives
inaccessible to the host.
5 Click Apply.
6 Repeat the above steps on another host if desired.

Modifying a Host

Scalar i500 User’s Guide

6

You can modify the host name and host type of a registered host.
Changing these settings will not affect your host access connections.You
cannot modify the WWPN of a registered host. If you need to change the
WWPN, you must delete the host and create a new one.

163

Chapter 6 Storage Networking
Configuring Host Access

To modify a host:
1 Click Setup > Host Access > Host Registration.
2 Select a host and click Modify.
3 Modify the host name or type and click Apply.

Deleting a Host

6

Deleting a host un-registers it with the library. The host is deleted from
the Registered Host list.
If the host is mapped to drives or partitions on the Setup - Connection
Configuration screen, you will need to disable all the mapped connections
before you can delete the host.
To delete a host:
1 Click Setup > Host Access > Host Registration.
2 Select a host and click Delete.
A dialog box opens asking you to confirm you want to delete the
host.
3 Click OK.

Scalar i500 User’s Guide

164

Chapter 7

Encryption Key Management

7

Encryption Key Management (EKM) is a licensable feature. You must
have an EKM license installed on your library in order to use the
encryption key management features described in this chapter.
The Scalar i500 supports three encryption key management systems,
which are described in Table 1. These systems work in conjunction with
the library to generate, protect, store, and manage encryption keys. The
keys are used by tape drives to encrypt information being written to, and
decrypt information being read from, tape media. The library
communicates with the encryption key management server(s). The
encryption keys pass through the library, so that encryption is
“transparent” to the applications. Using the library in this way is known
as “library managed encryption.”

Scalar i500 User’s Guide

Note:

These three solutions are not interoperable. The Scalar i500
library does not support more than one encryption key
management system on a single library.

Note:

Library firmware version 607G.GS003 (release i7.2) only
supports KMIP Key Managers. Other encryption systems are
not supported.

165

Chapter 7 Encryption Key Management

Table 1 Encryption Systems

Encryption System

Supported Tape Drives

Supported Media

Quantum Encryption Key
Manager (Q-EKM)

IBM LTO-4 Fibre Channel and SAS

LTO-4, LTO-5, and LTO-6 tape
cartridges

IBM LTO-5 Fibre Channel
IBM LTO-6 Fibre Channel
You must be running Q-EKM version 2.0
(or higher) to support IBM LTO-5 tape
drives.

Scalar Key Manager
(SKM)

HP LTO-4 Fibre Channel and SAS
HP LTO-5 Fibre Channel and SAS

LTO-4, LTO-5, and LTO-6 tape
cartridges

HP LTO-6 Fibre Channel and SAS
KMIP-compliant key
managers*

HP LTO-4 Fibre Channel and SAS
HP LTO-5 Fibre Channel and SAS

LTO-4, LTO-5, and LTO-6 tape
cartridges

HP LTO-6 Fibre Channel and SAS
* The Key Management Interoperability Protocol (KMIP®) is a specification developed by OASIS®. Its
function is to standardize communication between enterprise key management systems and encryption
systems. The Scalar i500 library provides a KMIP version 1.0 compliant encryption solution.
KMIP is only supported in certain environments. See the release notes for details.
If you purchase Q-EKM, Quantum Support will schedule an
appointment to install the application onto your key server(s). If you
purchase SKM, you will receive the software application, two key servers
(optional), and installation and configuration instructions. Installation for
KMIP-compliant systems differ according to the manufacturer, and may
include up to 10 key servers.
This chapter describes how to configure your encryption key
management (EKM) solution on the library. This chapter also describes
all of the EKM functions available on the library.
Refer to the Quantum Encryption Key Manager User’s Guide, the Scalar Key
Manager User’s Guide, or your KMIP key manager user’s guide for
information on how to manage your encryption system outside of the
library.

Scalar i500 User’s Guide

166

Chapter 7 Encryption Key Management
KMIP-compliant Encryption Key Management

This chapter covers:
• General Notes About Encryption on the Library on page 168
• About the EKM License on page 168
• Configuring Encryption Key Management on the Library on page 169
• Using EKM Path Diagnostics on page 183
• Viewing Tape Drive Encryption Settings on page 188
• Performing Scalar Key Manager Functions on the Library on
page 188
• Generating Data Encryption Keys on page 189
• Sharing Encrypted Tape Cartridges on page 192
• Exporting the Native Encryption Certificate on page 193
• Importing Encryption Certificates on page 194
• Exporting Data Encryption Keys on page 194
• Importing Data Encryption Keys on page 196
• Accessing the SKM Server Logs on page 197
• Using the SKM Encryption Key Import Warning Log on page 197

KMIP-compliant Encryption Key Management
The Key Management Interoperability Protocol (KMIP®) is a
specification developed by OASIS®. Its function is to standardize
communication between enterprise key management systems and
encryption systems. With version i7.2, the Scalar i500 provides a KMIP
version 1.0 compliant encryption solution.
KMIP is currently only supported with SafeNet® KeySecure servers.
Contact your Quantum representative for details.

Scalar i500 User’s Guide

167

Chapter 7 Encryption Key Management
KMIP-compliant Encryption Key Management

Details about the Scalar i500 KMIP-compliant implementation include:
• As with other encryption systems supported by the library, in order
to use KMIP-compliant encryption systems with the Scalar i500, you
must have an Encryption Key Management license installed on the
library.
• A minimum of two KMIP-compliant encryption servers are required
for failover purposes. A total of 10 KMIP-compliant encryption
servers are allowed, for increased failover capability.
See Configuring Encryption Key Management on the Library on page 169
for more information and instructions on how to configure KMIPcompliant encryption systems on the library.

General Notes About
Encryption on the Library7

Keep the following points in mind when using encryption on the library:
• Data written to encryption-supported and encryption-capable media
in EKM-supported tape drives will be encrypted unless data was
previously written to the media in a non-encrypted format. In order
for data to be encrypted, the media must be blank or have been
written to using library managed encryption at the first write
operation at the beginning of tape (BOT).
• You cannot append encrypted data to a non-encrypted tape.
• You cannot append non-encrypted data to an encrypted tape.
• Only one data encryption key can be used per tape cartridge.
• Encryption is configured by partition. Partitions must be configured
for “Library Managed Encryption.” EKM partitions must contain
only the tape drives supported by the encryption system you are
using. (For more information, see Step 6: Configuring Partitions for
Library Managed Encryption on page 180.

About the EKM License 7

Scalar i500 User’s Guide

If you purchase an EKM license after you purchased your library, you
must install the license key on your library to enable the EKM
functionality. The EKM license is sold on a per-drive basis. The license
corresponds to the number of tape drives that you can enable for library
managed encryption. If your library contains more encryption-enabled
tape drives than are covered by the license, you will need to purchase an
additional license to cover them. Your new license key replaces your
current license key and contains the entire license for the total number of
tape drives.

168

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Configuring Encryption Key Management on the Library
Make sure your Q-EKM, SKM, or KMIP-compliant key servers are
installed and running before configuring the library (see the Quantum
Encryption Key Manager User’s Guide, the Scalar Key Manager User’s Guide,
or your KMIP key manager user’s guide for instructions).
Then follow these steps, in order, to configure the library:
• Step 1: Installing the EKM License Key on the Library on page 169
• Step 2: Preparing Partitions for Library Managed Encryption on
page 170
• Step 3: Configuring Encryption Settings and Key Server Addresses
on page 170
• Step 4: Installing TLS Certificates on the Library (SKM Only) on
page 174
• Step 5: Running EKM Path Diagnostics on page 180
• Step 6: Configuring Partitions for Library Managed Encryption on
page 180
Note:

Scalar Key Manager is very sensitive to network instability
due to the large amount of operations occurring in rapid
succession. If you get an error stating that an SKM operation
failed, check network functionality and try the operation
again.
Make sure ports 80, 6000, and 6001 on the SKM servers are
opened up in a bi-directional mode on all firewalls in your
network. If they are not, the library will not be able to
communicate with the SKM servers.

7

Step 1: Installing the EKM License Key on the Library
If your EKM license key is not already installed on the library, install it
now.

Scalar i500 User’s Guide

169

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

7

Step 2: Preparing Partitions for Library Managed Encryption
For each partition on which you want to enable library managed
encryption, do the following:
1 Make sure the partition contains encryption-supported and
encryption-capable tape drives and media. Note the following:
•

Q-EKM partitions must contain only IBM LTO-4, IBM LTO-5,
and/or IBM LTO-6 tape drives.
Note:

You must be running Q-EKM version 2.0 (or higher)
to support IBM LTO-5 or LTO-6 tape drives.

•

SKM partitions must contain only HP LTO-4, HP LTO-5,and/or
HP LTO-6 tape drives. SKM media must have valid barcode
labels affixed. SKM does not support the use of unlabeled media.

•

KMIP partitions must contain only HP LTO-4 and/or HP LTO-5
tape drives.

1 On the tape drives, install the latest version of firmware that is
qualified for the library firmware installed on your library. Refer to
the library release notes for the correct version of tape drive
firmware. (It is recommended that you upgrade library firmware to
the latest release.)
2 Unload tape cartridges from all tape drives in the partitions on which
you are configuring EKM.
Step 3: Configuring Encryption Settings and Key Server Addresses7
Configure encryption settings and key server information as follows:
1 From the Web client, select Setup > Encryption > System
Configuration.
The Setup - Encryption System Configuration screen displays (see
Figure 25).

Scalar i500 User’s Guide

170

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Figure 25 Setup - Encryption
System Configuration (KMIP
Key Manager)

2 Key Server Type — This field only appears if you have HP tape
drives installed in the library. If this field is visible, select which
encryption solution you plan to use (Q-EKM, SKM, or KMIP Key
Manager).
3 Automatic EKM Path Diagnostics — Enable or disable as desired;
however, it is recommended you leave the default. For more
information, see Using Automatic EKM Path Diagnostics on
page 186). When enabled, this feature performs a check, at specified
intervals, to make sure both key servers are connected to the library
and functioning properly. The library generates a RAS ticket if there
are problems.

Scalar i500 User’s Guide

171

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

4 Interval — If Automatic EKM Path Diagnostics is enabled, select the
interval at which the library performs the diagnostics.
5 Test Warning Threshold — For Q-EKM only. If Automatic EKM
Path Diagnostics is enabled, specify the number of consecutive
missed test intervals required to generate a RAS ticket.
6 SSL Connection — Enable or disable as follows, depending on which
key server you are using:
•

Q-EKM — To enable SSL for communication between the library

and the EKM servers, select the SSL Connection check box. The
feature is disabled by default. If you enable SSL, you must make
sure that the port numbers listed in the Port text boxes (below)
match the SSL port numbers set on the Q-EKM servers. The
default SSL port number is 443.
Note:

Keys are always encrypted before being sent from the
Q-EKM key server to a tape drive, whether SSL is
enabled or not. Enabling SSL provides additional
security.

•

SKM — SSL is always enabled. The SSL port number is always
6000.

•

KMIP Key Manager — SSL is always enabled.
Note:

For SKM and KMIP Key Manager, the library actually
uses Transport Layer Security (TLS), a more secure
successor to SSL, to communicate with the
encryption servers.

7 Key Server IP Address or Host Name — In the text boxes, assign
your key servers in the order in which you want failover to occur.
The “#” column denotes the server failover order. Once you add the
servers, you can change the failover order by clicking the up/down
arrow buttons in the Order column.

Scalar i500 User’s Guide

172

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Note:

Q-EKM requires one or two servers. If you do not plan to
use a secondary key server, you may type a zero IP
address, 0.0.0.0, in the #2 text box, or you may leave the
text box blank.
SKM requires two servers.
KMIP Key Manager requires at least two servers and can
have up to 10 servers for increased failover capacity.

For an initial key request, the library tries server #1 (the primary
server) first. If server #1 is not available to perform a key request, the
library tries server #2. For KMIP key managers, if server #2 is not
available, the library will try server #3, and so on, in order.
Once the library identifies a server that can perform the request, this
server remains the active server until it fails a key request or the
library is rebooted. At that point, the library starts over and uses
server #1 for key requests.
In the text boxes, type either:
•

The IPv4 or IPv6 address of the key server (if DNS is not
enabled), or

•

The host name of the key server (if DNS is enabled).

8 Port — In the Port text boxes, type the port numbers corresponding to
the listed servers. The port number listed in the text box must match
the port number on the server. Note the following:
•

Q-EKM — The default port number is 3801 unless SSL is enabled.

If SSL is enabled, the default port number is 443.
Note:

Scalar i500 User’s Guide

If you change the Q-EKM port number listed in the
Port text box from the default setting on the library,
you must also change the port number on the actual
key server to match, or library managed encryption
will not work properly. See the Quantum Encryption
Key Manager User’s Guide for information on setting
the port number on the Q-EKM key server.

173

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Note:

9

If you are using a secondary Q-EKM key server, then
the port numbers for both the primary and secondary
key servers must be set to the same value. If they are
not, synchronization and failover will not occur.

•

SKM — The port number is always 6000. You cannot change
SKM port numbers.

•

KMIP Key Manager — The port number must match the
configured port number on the KMIP key manager server. A
typical port number used for communication between the KMIP
key manager server and the library is port 9003.

Click Apply.
Note:

You cannot edit the encryption system configuration
settings when any partition is enabled for library
managed encryption. If this happens, go to Setup >
Encryption > Partition Configuration, change all EKM
partition settings from Enable Library Managed to
Allow Application Managed. Then make your changes
to the system configuration settings. Finally, go back and
change all the EKM partition settings to Enable Library
Managed.

10 Ensure all ports corresponding to the EKM servers are open on your
firewall to allow the library to connect to the servers. For SKM, ports
80, 6000, and 6001 must be open.

7

Step 4: Installing TLS Certificates on the Library (SKM Only)
If you are running SKM or a KMIP key manager, Transport Layer
Security (TLS) communication certificates with valid dates must be
installed on the library in order for the library to communicate securely
with attached EKM servers.
Note:

Scalar i500 User’s Guide

If you are using Q-EKM, skip this step. No TLS certificates are
required.

174

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

At any time, you may install a new set of TLS certificates to overwrite the
existing set. The new TLS certificates must all be valid or the overwrite
will not occur and the existing certificates will remain in place.
Take one the following actions, according to which encryption system
you are using.

Encryption System

Action

Scalar Key Manager (SKM)

If you purchased your library with firmware
version 570G or higher, the library came with
TLS certificates pre-installed. You can check
the Web client to see whether TLS certificates
are installed (see Checking for Current
Certificates on page 175).
If valid TLS certificates are currently installed,
you do not need to do anything. However, if
you wish, you may install your own
certificates to replace the existing certificates
(see Installing Your Own TLS Certificates on
the Library on page 177).
If valid TLS certificates are not installed, you
must install them. You can install either of the
following:
Quantum-provided TLS certificates (see
Installing Quantum-Supplied TLS Certificates
on the Library on page 176).
Your own TLS certificates (see Installing Your
Own TLS Certificates on the Library on
page 177).

KMIP-compliant key
management

TLS certificates will be provided by your KMIP
server administrator. Install certificates as
described in Installing Your Own TLS
Certificates on the Library on page 177.

Checking for Current Certificates From the Tools menu, select EKM7
Management > Import Communication Certificates.
The Tools - TLS Communication Certificate Import screen appears (see
Figure 26).

Scalar i500 User’s Guide

175

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

If TLS certificates are currently installed, they will be listed in a table at
the bottom of the screen. If they are not installed, a message appears at
the bottom of the screen stating that certificates are not installed.

Figure 26 TLS Communication
Certificate Import Screen

Installing Quantum-Supplied TLS Certificates on the Library
7
Quantum-supplied TLS certificates are only available for use with SKM.
The Quantum-supplied certificates come on a CD which you received.
The TLS certificates are bundled in a single file.
1 Ensure that the date on both SKM servers and the library are set to
the current date. Incorrect date settings may interfere with the TLS
certificates and cause the library to stop communicating with the
SKM servers.
2 Insert the CD into the CD ROM drive of your computer. Either copy
the file to a known location on your computer or use the CD as the
location from which you will retrieve the file.
Scalar i500 User’s Guide

176

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

3 From the Tools menu, select EKM Management > Import
Communication Certificates.
The Tools - TLS Communication Certificate Import screen
opens (see Figure 26). If TLS certificates are currently installed, they
will be listed in a table at the bottom of the screen. If they are not
installed, a message appears at the bottom of the screen stating that
certificates are not installed.
4 From the Select the Certificate Type to install drop-down list, select
SKM.
5 Select the Use the Quantum Certificate Bundle check box.
6 Click the Browse button next to the Quantum Communication
Certificate Bundle File field to locate the TLS certificate file.
7 Click Open.
8 Click Apply.
9 Verify that the table at the bottom of the screen is present and
contains the required certificates.
Installing Your Own TLS Certificates on the Library Follow these 7
instructions to install your own TLS certificates (for SKM), or when
installing TLS certificates for KMIP key managers. When providing your
own certificates, it is assumed you understand the concepts of PKI and
can access the tools or third-party resources needed to generate or obtain
certificates.

Scalar i500 User’s Guide

Note:

If you are using SKM: You must be running SKM 1.1 or
higher on your SKM servers in order to install your own TLS
certificates. If you install your own TLS certificates on the
library, you must also install your own certificates on the SKM
servers. Similarly, if you use the Quantum-provided TLS
certificates on the SKM servers, you must also use the
Quantum-provided TLS certificates on the library. See the
Scalar Key Manager User’s Guide for information about
installing TLS certificates on the SKM servers.

Note:

If you are using KMIP key managers: Your KMIP server
provider will provide TLS communication certificates.

177

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

You need to provide the following certificates:
Encryption System

Certificates Required

SKM

• Root Certificate (also called the CA certificate,
or Certificate Authority Certificate)
• Client Certificate
• Admin Certificate

KMIP key managers

• Root Certificate (also called the CA certificate,
or Certificate Authority Certificate)
• Client Certificate

These files must be in the proper format, as follows. If any of the
following requirements is not met, none of the certificates will be
imported.
• The Root Certificate must be 2048 bits and be in PEM format.
• The Admin and Client certificates must be 1024 bits and be in
pkcs#12 (.p12) format, with a separate certificate and private key
contained in each.
• The Admin and Client certificates must be signed by the Root
Certificate.
• Certificates must have the Organization name (O) set in their Issuer
and Subject info.
• The Admin certificate must have its Organizational Unit name (OU)
set as “akm_admin” in its Subject Info.
• The same Root Certificate must be installed on the encryption key
servers and the library.
• All the certificates must have a valid validity period according to the
date and time settings on the encryption key server.
To install your own certificates:
1 Ensure that the date on all encryption key servers and the library are
set to the current date. Incorrect date settings may interfere with the
TLS certificates and cause the library to stop communicating with the
key servers.
2 Place the TLS certificate files in a known location on your computer.

Scalar i500 User’s Guide

178

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

3 From the Tools menu, select EKM Management > Import
Communication Certificates.
The Tools - TLS Communication Certificate Import screen opens
(see Figure 26 on page 176). If TLS certificates are currently installed,
they will be listed in a table at the bottom of the screen. If they are not
installed, a message appears at the bottom of the screen stating that
certificates are not installed.
4 From the Select the Certificate Type to install drop-down list, select
your encryption key management system (SKM or KMIP Key
Manager).
5 Retrieve the certificate files as follows:
For SKM
a Make sure the Use the Quantum Certificate Bundle check box is
deselected.
b

Click Browse to retrieve the Root Certificate File.

c

Click Browse to retrieve the Admin Certificate File.

d

In the Admin Certificate Password field, type the password used
when you generated the certificate files.

e

Click Browse to retrieve the Client Certificate File.

f

In the Client Certificate Password field, type the password used
when you generated the certificate files.

g

If you used the same password for the client and admin
certificates, you can select the Use Admin’s Password check box.

For KMIP Key Manager
a Click Browse to retrieve the Root Certificate File.
b

Click Browse to retrieve the Client Certificate File.

c

In the Client Certificate Password field, type the password used
when generating the certificate files.

6 Click Apply to import the files onto the library.
7 Verify that the table at the bottom of the screen is present and
contains the required TLS certificates.

Scalar i500 User’s Guide

179

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

7

Step 5: Running EKM Path Diagnostics
Perform EKM Path Diagnostics as described in Using EKM Path
Diagnostics on page 183.

7

Step 6: Configuring Partitions for Library Managed Encryption
Encryption on the Scalar i500 tape library is enabled by partition only.
You cannot select individual tape drives for encryption; you must select
an entire partition to be encrypted.
Configure the partitions as follows:
1 From the Web client, select Setup > Encryption > Partition
Configuration.

The Setup - Encryption Partition Configuration screen appears (see
Figure 27).
Note:

Scalar i500 User’s Guide

Your screen might look slightly different depending on
which encryption system you are using.

180

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Figure 27 Setup - Encryption
Partition Configuration Screen

A list of all your partitions displays, along with a drop-down list
displaying the encryption method for each partition. The Encryption
Method applies to all encryption-capable tape drives and media in that
partition. Table 7 on page 181 describes the partition encryption methods.

Table 7 Partition Encryption
Methods

Scalar i500 User’s Guide

Encryption Method

Description

Enable Library
Managed

For use with EKM. Enables encryption support via a

connected EKM key server for all tape drives and
encryption-capable media assigned to the partition.

181

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Allow Application
Managed

Not for use with EKM. Allows an external backup

application to provide encryption support to all
encryption-capable tape drives and media within the
partition. The library will NOT communicate with the
EKM key server on this partition.
This is the default setting if you have encryptioncapable tape drives in the partition. This option
should remain selected unless you are connecting the
library to an external EKM server.

Note: If you want an external application to manage

encryption, you must specifically configure the
application to do so. The library will not participate in
performing this type of encryption.

Unsupported

Means that no tape drives in the partition support
encryption.
If Unsupported is shown, it will be greyed out and you
will not be able to change the setting.

2 For each partition on which you are configuring EKM, change the
Encryption Method to Enable Library Managed. (To disable EKM,
select Allow Application Managed).

Scalar i500 User’s Guide

Note:

When you change the encryption method on a partition,
the partition is taken offline. When the change completes
successfully, the partition comes back online
automatically. If the operation does not complete
successfully, the partition remains offline until you turn it
back online manually or restart the library.

Note:

When you change a partition from Enable Library
Managed to Allow Application Managed, the data that
was written to the tapes while the partition was
configured for library managed encryption can no longer
be read, until you change the partition back to Enable
Library Managed.

182

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

3 SKM Only — FIPS (Federal Information Processing Standard) is a
U.S. government standard relating to computer security and
encryption. To enable FIPS mode on an SKM partition, select the FIPS
check box. To disable FIPS, clear the FIPS check box.
See FIPS-Certified Encryption Solution on page 199 for more
information. FIPS mode is only available with SKM.
4 Click Apply.
5 Save the library configuration.

Using EKM Path
Diagnostics

7

The EKM Path Diagnostics consists of a series of short tests to validate
whether the key servers are running, connected, and able to serve keys as
required.
Run the Manual EKM Path Diagnostics any time you change the key
server settings or library encryption settings. If you are running Q-EKM,
you should also run the Manual EKM Path Diagnostics whenever you
replace a tape drive. It is recommended that you test each tape drive that
communicates with Q-EKM key servers.
The diagnostics consists of the following tests:
Note:

For Q-EKM only: The tape drive used for the test must be
unloaded, ready, and online in order to run any of the tests.

• Ping — Verifies the Ethernet communication link between the library
and the key servers.
• Drive (Q-EKM only) — Verifies the tape drive’s path in the library
(communication from library to tape drive sled and from tape drive
sled to tape drive). The tape drive must be unloaded, ready, and
online in order to run this test. If this test fails, the Path and Config
tests are not performed.
• Path — Verifies that EKM services are running on the key servers.
Note:

For Q-EKM only: This test cannot run if the Drive test fails.

• Config — Verifies that the key servers are capable of serving
encryption keys.

Scalar i500 User’s Guide

183

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Note:

For Q-EKM only: This test cannot run if the Drive test fails.

If any of the tests fail, try the following resolutions and run the test again
to make sure it passes:
• Ping Test Failure — Verify that the key server host is running and
accessible from the network to which the library is connected.
• Drive Test Failure — Look for any tape drive RAS tickets and follow
the resolution instructions in the ticket.
• Path Test Failure — Verify that the key server is actually running and
that the IP address, port, and SSL settings configured on the library
are correct. Check to see if there is a network configuration issue,
such as a firewall, preventing communication with the server.
• Config Test Failure —

Differences Between
Manual and Automatic
EKM Path Diagnostics 7

•

Q-EKM: Verify that the key server is set up to accept the tape

•

SKM: A database inconsistency has been detected. Contact

•

KMIP Key Manager: Indicates a KMIP key server configuration
problem. The server does not support all features necessary for
the library to use it as a key server. Contact your KMIP server
administrator for assistance.

drive you are testing.

Quantum Support.

There are two ways to perform EKM Path Diagnostics:
• Using Manual EKM Path Diagnostics on page 185
• Using Automatic EKM Path Diagnostics on page 186
For SKM and KMIP key management, the manual and automatic
diagnostics run in the same way. Partitions remain online for either the
Manual or Automatic diagnostics.
For Q-EKM, the Manual diagnostics differs from the Automatic

diagnostics in the following ways:

• The Manual diagnostics takes affected partitions offline during the
tests. When the tests complete, the partitions are returned to the
online/offline state they were in before the tests began.

Scalar i500 User’s Guide

184

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

• The Automatic diagnostics does not take partitions offline, but it may
delay moves to tape drives while they are being tested.
• The Manual diagnostics requires that you select one tape drive to use
for the test. Since the test only validates the selected drive, if you
want to test the path for each tape drive, you must run the test
multiple times (once for each drive). In addition, if the tape drive is
not available (it must be unloaded, ready, and online), the Drive,
Path, and Config tests are not performed.
• The Automatic diagnostics tests every connected EKM server in turn,
and the library selects the tape drive to use for each test. If the
selected tape drive is not available (it must be unloaded, ready, and
online), then the library tries another tape drive that is connected to
the key server until it finds one that is available. If no tape drives
connected to a particular key server are available, then that server is
skipped and the tests are not performed. If a server is skipped for “X”
number of consecutive test intervals (where “X” is configurable on
the Web client), the library generates a RAS ticket. If a tape drive
remains loaded for a long time, it is possible that it will never be
tested. If you want to test a specific tape drive, then you should use
the Manual EKM Path Diagnostics. In particular, if you replace a tape
drive, run the Manual EKM Path Diagnostics.

Using Manual EKM Path
Diagnostics
7
1 Access the EKM Path Diagnostics screen in one of two ways:
•

Enter library Diagnostics. From the Web client select Tools >
Diagnostics, and click OK to the message that appears. From the
Diagnostics menu, select EKM > EKM Path Diagnostics.
Note:

•

Scalar i500 User’s Guide

Performing Diagnostics will log off all other users of
the same or lower privileges and take your partitions
offline. When you exit Diagnostics, the partitions
automatically come back online.

Select Setup > Encryption > System Configuration or Setup >
Encryption > Partition Configuration and click the link that says
“Click here to run EKM Path Diagnostics.”

185

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

2 Q-EKM Only: A list of all the tape drives enabled for librarymanaged encryption is displayed, along with the tape drive status
and the partition in which each tape drive resides.
3 Q-EKM Only: Select the tape drive on which you want to perform
diagnostics and click Apply. Tape drives must be unloaded, ready,
and online in order for the test to run.
A dialog box appears telling you that the selected partition will be
taken offline. When the test completes, the partition automatically
comes back online.
4 Click OK to start the Q-EKM diagnostics, or click Apply to start the
SKM or KMIP diagnostics.
5 The library performs the diagnostics and displays pass/fail results on
each of the tests in the Progress Window.
Note:

The diagnostics tests may take several minutes to
complete.

6 Do one of the following:
•

If Completed appears in the Progress Window, the diagnostics
were performed (this does not mean that the diagnostics passed,
just that the diagnostics were performed). Click Close to close the
Progress Window.

•

If Failure appears in the Progress Window, the diagnostics were
not performed. Follow the instructions listed in the Progress
Window to resolve any issues that occurred during the operation.

7 If you are entered the Diagnostics menu, select Exit from the menu
bar and then click OK in the dialog box that appears.

Using Automatic EKM
Path Diagnostics

7

You can enable the library to automatically perform EKM Path
Diagnostics at selected intervals. During each interval, the library tests
every configured key server. The default test interval is 10 minutes. The
library generates a RAS ticket if there are problems.
• For Q-EKM: Automatic EKM Path Diagnostics is disabled by default.
It is recommended that you leave Automatic EKM Path Diagnostics
disabled, unless network interruptions are a common cause of
encryption failures at your site.

Scalar i500 User’s Guide

186

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Caution:

Q-EKM Only: Running Automatic EKM Path
Diagnostics may cause an increase in RAS tickets
if tests are skipped due to tape drives being
unavailable for a configurable number of
consecutive test intervals. To reduce the
occurrences of RAS tickets, you can specify the
number of consecutive test intervals required to
generate a RAS ticket to a higher number, or you
can set the library to never generate a RAS ticket
for missed test intervals.

• For SKM and KMIP Key Manager: Automatic EKM Path Diagnostics is
enabled by default and should always be left enabled. You should not
need to disable it unless Quantum Support directs you to do so.
For a list of tests performed, see Using EKM Path Diagnostics on
page 183.
To enable Automatic EKM Path Diagnostics:
1 From the Web client, select Setup > Encryption > System
Configuration.
2 Select the Automatic EKM Path Diagnostics check box.
3 Select a test interval from the Interval drop-down list.
4 Q-EKM Only: From the Test Warning Threshold drop-down list,
select the number of consecutive, missed test intervals required
before the library generates a RAS ticket informing you that the test
could not be performed within the specified number of test intervals.
You can select “Off” or any value from 1 to 24. If you select “Off,” the
library will never generate a RAS ticket, no matter how many tests
are missed. The default threshold is 3.

Viewing and Changing
the Active Key Server 7

Scalar i500 User’s Guide

The Key Manager Status screen shows you which encryption key server
is currently active, and allows you to change the active server. When you
change the active server, it means that the next key server operation and
all subsequent key server operations will be performed using the new
active server until that server fails or the key server settings are changed.

187

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Note:

This feature is currently only available with KMIP Key
Manager.

1 From the Web client, select Tools > EKM Management > Server
Status.
The Key Manager Status screen appears. A list of all your connected
EKM servers displays. The currently active server displays in bold
green type with the word “(Active)” after it.
2 To choose a different server to be the active server, select that server’s
radio button and click Apply.

Viewing Tape Drive
Encryption Settings

7

You can view the encryption settings in the following ways:
• System Information Report — To view encryption information on
all key servers, partitions, and tape drives, select Reports > System
Information from the Web client.
• Library Configuration Report — To view the encryption status of a
selected tape drive or tape cartridge, select Reports > Library
Configuration from the Web client and click a tape drive or slot. The
encryption status is displayed in a pop-up status window.
• Partition Encryption — From the Web client, select Setup >
Encryption > Partition Configuration to view and change the
encryption settings of partitions. See Step 6: Configuring Partitions
for Library Managed Encryption on page 180 for more details.

Performing Scalar Key
Manager Functions on
the Library
7

Once the SKM servers are set up, most SKM functions occur
automatically without user action required. SKM provides some key
management capability through the library Web client.
For a complete description and instructions for using these features, see
the library Web client online help.
These functions are:
• Generating Data Encryption Keys on page 189
• Sharing Encrypted Tape Cartridges on page 192
• Exporting the Native Encryption Certificate on page 193

Scalar i500 User’s Guide

188

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

• Importing Encryption Certificates on page 194
• Exporting Data Encryption Keys on page 194
• Importing Data Encryption Keys on page 196
• Accessing the SKM Server Logs on page 197
• Using the SKM Encryption Key Import Warning Log on page 197

7

Generating Data Encryption Keys

Data encryption keys are generated in sets of a specified quantity (see the
Scalar Key Manager User’s Guide for more information).
The library tracks data encryption key usage and reminds you to generate
more keys when needed. If you try to generate data encryption keys on
an SKM server that already has sufficient unused data encryption keys,
then it will not create more. You will receive a message to that effect on
the library remote Web client.
Note:

Each library that you connect to an SKM server requires its
own set of data encryption keys. Each library only pulls data
encryption keys from the set that “belongs” to it. This means
that an SKM server may contain several distinct sets of data
encryption keys. When the data encryption keys for one
library have all been used, then more keys must be
generated.

You can generate data encryption keys in the following ways:
• Generating Data Encryption Keys at Initial Setup
• Generating Data Encryption Keys When 80% Depleted
• Generating Data Encryption Keys When 100% Depleted
• Manually Generating Data Encryption Keys

7

Generating Data Encryption Keys at Initial Setup
At initial setup, the library triggers each SKM server to generate a set of
data encryption keys. The process is described in Step 6: Configuring
Partitions for Library Managed Encryption on page 180.

Generating Data Encryption Keys When 80% Depleted When an 7
SKM server has used 80 percent of the data encryption keys assigned to a
Scalar i500 User’s Guide

189

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

particular library, that library attempts to automatically generate data
encryption keys on the SKM server. Both SKM servers must be running
and operational in order for automatic key generation to succeed.
• If automatic key generation succeeds, a RAS ticket informs you the
keys were generated and instructs you to back up both SKM server
keystores as soon as possible.
• If automatic key generation fails, the library tries again every time a
new key is requested, until the keys are 90 percent depleted. At that
point, the library stops trying to auto-generate keys and issues a RAS
ticket stating that you must manually generate keys. See Manually
Generating Data Encryption Keys on page 190.
Generating Data Encryption Keys When 100% Depleted If an SKM 7
server completely runs out of data encryption keys for a particular
library, that library generates a RAS ticket, which states that you have run
out of data encryption keys and that the library attempted to fail over to
the other SKM server. If this happens, it is imperative that you manually
generate a new set of data encryption keys on the depleted server
immediately and then back up both SKM servers. See Manually
Generating Data Encryption Keys on page 190.
Manually Generating Data Encryption Keys To manually generate 7
data encryption keys, you need to temporarily disable library managed
encryption on a partition, and then enable it again. Enabling library
managed encryption on a partition triggers the library to check both SKM
servers to see if new data encryption keys are needed. If so, it creates the
keys.
Note:

The data encryption key generation process takes
approximately 15 minutes. You should not run any library or
host-initiated operations on SKM partitions during key
generation and backup.

Avoid manually generating keys on more than five libraries
simultaneously as the key generation process is resource-intensive on the
server. Generating keys manually on more than five libraries at once
could result in a failure to complete the key generation operation, or
interfere with key retrieval operations. If a failure does occur during key
generation, wait 10 minutes, then try to start it again. The key generation
process will resume from where the error was encountered.

Scalar i500 User’s Guide

190

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

To manually generate data encryption keys:
1 Make sure that both SKM servers are running and operational.
2 From the library’s Web client, access the encryption partition
configuration screen (Setup > Encryption > Partition
Configuration).
3 Select an SKM partition configured for library managed encryption,
and temporarily disable library managed encryption by changing the
encryption method from Enable Library Managed to Allow
Application Managed. Remember which partition it is, because you
will be changing it back in a few minutes. Make sure to click Apply.
Caution:

When you change the partition’s encryption
method to Allow Application Managed, the
data that was written to the tapes while the
partition was configured for Enable Library
Managed can no longer be read, until you
change the partition back to Enable Library
Managed. You will only be disabling for a short
time, and then changing back to Enable Library
Managed (just to trigger the key generation
process) so this should have little effect, unless
you forget to turn it back to Enable Library
Managed.

4 Wait 3 minutes to allow the changes to complete.
5 Go back to the encryption partition configuration screen and change
the partition back to Enable Library Managed. Again, make sure to
apply the changes.
6 Wait for the process to complete before resuming library operations.
7 Back up both SKM servers. You must back up both SKM servers
every time you generate new data encryption keys to protect your
data in case of catastrophic server failure. See the Scalar Key Manager
User’s Guide for instructions on backing up the SKM servers.

Scalar i500 User’s Guide

191

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

7

Sharing Encrypted Tape Cartridges
If you are using SKM, you can share encrypted tapes with other
companies and individuals who also use SKM for managing encryption
keys.

Each SKM server provides a unique encryption key for each tape
cartridge that is encrypted. To read an encrypted tape in a library that is
attached to an SKM server that is different than the server that originally
provided the encryption key, the encryption key from the originating
(i.e., source) SKM server needs to be shared with the receiving (i.e.,
destination) SKM server. The key (or list of keys, if there is more than one
tape), is exported from the source SKM server to a file, which is sent to
the destination recipient. Each key contained in the file is encrypted using
the public key of the destination SKM server. The destination SKM server
provides its public key to the source SKM server as part of a native
encryption certificate, which the source SKM server uses to wrap
(encrypt) the encryption keys for transport. Upon arrival, the file
containing the wrapped encryption keys can only be unwrapped by the
corresponding private key, which resides on the destination SKM server
and is never shared.
The process is as follows:
1 The destination administrator exports the native encryption
certificate that belongs to the destination SKM server. (The two SKM
servers in a server pair share the same native encryption certificate.)
The native encryption certificate is saved as a file to a location
specified by the administrator on a computer (see Exporting the
Native Encryption Certificate on page 193).
2 The destination administrator e-mails the native encryption
certificate file to the source administrator.
3 The source administrator saves the native encryption certificate file to
a location on a computer, and then imports it onto the source SKM
server (see Importing Encryption Certificates on page 194).
4 The source administrator exports the data encryption keys, assigning
the destination SKM server’s native encryption certificate to wrap
(encrypt) the keys. The file containing the wrapped encryption keys
is saved to a location on a computer specified by the source
administrator. See Exporting Data Encryption Keys on page 194.
5 The source administrator e-mails the file containing the wrapped
data encryption keys to the destination administrator.

Scalar i500 User’s Guide

192

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

6 The destination administrator saves the file containing the wrapped
data encryption keys to a location on a computer, and then imports
the keys onto the destination SKM server (see Importing Data
Encryption Keys on page 196).
7 The destination library can now read the encrypted tapes.
For more information about the key servers and library managed
encryption best practices, please refer to the Scalar Key Manager User’s
Guide.

7

Exporting the Native Encryption Certificate

To receive encryption keys from another SKM server, you must first send
your SKM server’s native encryption certificate to that server. The public
key contained in the native encryption certificate will be used to wrap
(encrypt) the encryption keys to protect them during transport to you.
Note:

This function is available to administrators and only applies
to SKM servers. Since the native encryption certificate is the
same for both servers in an SKM server pair, you may export it
when only one SKM server is connected/operational.

To export an encryption certificate:
1 Before starting this process, read and follow the sequence of steps
outlined in Sharing Encrypted Tape Cartridges on page 192.
2 From the Tools menu, select EKM Management > Encryption
Certificate > Export.
3 Click Apply to export your SKM server’s native encryption
certificate.
4 Click Close to close the Progress Window.
5 In the File Download dialog box that displays, click Save.
6 In the Save As dialog box that opens, choose a location in which to
save the file, then click Save.

Scalar i500 User’s Guide

193

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Importing Encryption Certificates

7

The encryption certificate contains a public key that is used to wrap
(encrypt) encryption keys prior to transporting them to another SKM
server. When sharing tape cartridges, you need to import the encryption
certificate of the destination SKM server.
Note:

This function is available to administrators and only applies
to SKM servers. Both SKM servers must be connected and
operational in order to import encryption certificates.

To import encryption certificates:
1 Before starting this process, read and follow the sequence of steps
outlined in Sharing Encrypted Tape Cartridges on page 192.
2 Receive the encryption certificate file from the destination SKM
server administrator and save it to a known location on your
computer.
3 From the Tools menu, select EKM Management > Encryption
Certificate > Import.
4 Click Browse to locate the saved encryption certificate file.
5 Click Open.
6 Click Apply to import the certificate onto your SKM server.
Exporting Data Encryption Keys

7

SKM servers provide a unique encryption key for each tape cartridge that
is encrypted. In order for another (i.e., destination) SKM server to read
tapes encrypted by your SKM server (i.e., source), you need to export the
encryption keys used to encrypt those tapes and send them to the
destination server.
Note:

Scalar i500 User’s Guide

This function is available to administrators and only applies
to SKM servers. Both SKM servers must be connected and
operational in order to export data encryption keys.

194

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

Note:

Missing/Changed Barcode Labels — If a tape cartridge
barcode label is missing, the key used to encrypt the tape will
not be exported in an Export Current operation. If a tape
cartridge barcode label is changed, the key used to encrypt
the tape will not be exported in an Export Current or Export
Selective operation. The keystore metadata pairs the data
encryption key with the label that was present at the time of
first encryption. If the label is lost or changed, the pairing is
lost, and these export options will either export no key or
possibly the wrong key. Encryption read/write operations are
not affected by media barcode label and will continue to
work correctly.

To export encryption keys:
1 Before starting this process, read and follow the sequence of steps
outlined in Sharing Encrypted Tape Cartridges on page 192.
2 From the Tools menu, select EKM Management > Encryption Key >
Export.
3 Assign the encryption certificate with which you will “wrap”
(encrypt) the keys by selecting it from the Certificate Name Used For
Export drop-down list. Choose the certificate that belongs to the
server to which the keys will be imported.
Note:

The owner of that server should have sent you the
certificate and you should have imported it (see Sharing
Encrypted Tape Cartridges on page 192 and Importing
Encryption Certificates on page 194). The drop-down list
contains all of the encryption certificates that you have
ever imported onto your SKM servers (indicated by the
word “imported” in the list), as well as the certificate
belonging to your SKM server pair (indicated by the word
“native” in the list).

4 Select which SKM encryption keys to export from the following
options:
•

Scalar i500 User’s Guide

Export Used — Exports all the keys that have ever been used to
encrypt tape cartridges in the library performing this export. Also
exports all keys that were imported onto the key server, via a
“key import” operation, from any library.
195

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

•

Export Current — Exports all the keys that were used to encrypt
the tape cartridges that are currently in the library performing
this export. This includes storage slots, I/E stations, and tape
drives. If a tape cartridge is no longer in the library, the key used
to encrypt the tape will not be exported. If a tape cartridge
barcode label is missing or changed, the key used to encrypt the
tape will not be exported.

•

Export Selective — Exports only the key(s) associated with a
string of characters that you type into the text box. Each key is
associated with its encrypted tape cartridge, identified by the
tape cartridge barcode. You can type in all or part of a tape
cartridge barcode, and any keys that are associated with that
string will be exported. This is helpful if you only want to export
a single key associated with a particular tape cartridge. If a tape
cartridge barcode label is changed, the key used to encrypt the
tape will not be exported.

5 Click Apply.
All the exported keys are saved to a single encryption key file.
6 A Save As dialog box opens allowing you to save the encryption key
file to a location on your computer. Choose a location and click Save.

7

Importing Data Encryption Keys

SKM servers provide a unique encryption key for each tape cartridge that
is encrypted. In order to read tapes encrypted by a different (i.e., source)
SKM server, you need to import the encryption keys used to encrypt
those tapes onto your SKM server (i.e., destination).
Note:

This function is available to administrators and only applies
to SKM servers. Both SKM servers must be connected and
operational in order to import data encryption keys.

To import encryption keys:
1 Before starting this process, read and follow the sequence of steps
outlined in Sharing Encrypted Tape Cartridges on page 192.
2 Receive the file of encryption keys from the source SKM server and
save it in a known location on your computer.

Scalar i500 User’s Guide

196

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

3 From the Tools menu, select EKM Management > Encryption Key >
Import.
4 Click Browse to locate the saved file of encryption keys.
5 Click Open.
6 Click Apply to import the keys onto your SKM server.
7 Back up both SKM servers following the instructions in the SKM
user’s guide.
In case of an incomplete import, the library displays a message and
generates a RAS ticket. For instructions on what to do if this happens, see
Using the SKM Encryption Key Import Warning Log on page 197.

7

Accessing the SKM Server Logs

• The library can download the audit and error logs from the SKM
servers. You should not need to retrieve these logs unless Quantum
Support directs you to do so. You can download the logs to your
computer or e-mail them to a recipient. In order to e-mail the logs, the
library e-mail account must be configured (see “Configuring the
Library E-mail Account” in the Scalar i500 User’s Guide).
• The path to open the appropriate screen is as follows:
• From the Web client, select Tools > EKM Management > Retrieve
SKM Logs.

7

Using the SKM Encryption Key Import Warning Log

This log lists the tape cartridges for which encryption keys failed the most
recent encryption key import operation. If you have only partial success
when importing a file of encryption keys (meaning, some keys import
successfully but some keys do not), the library displays an “import
warning” message and generates a RAS ticket that directs you to view
this log to see which keys did not get imported.
For each key that failed the import, the log provides a message type that
is either:
• Error — The key could not be imported.
• Warning — The key was imported, but the metadata update failed.

Scalar i500 User’s Guide

197

Chapter 7 Encryption Key Management
Configuring Encryption Key Management on the Library

For each key that failed the import, the log provides one of the following
message descriptions:
• CRC Data Missing — Error. Metadata is missing for the key. This
means that the export file is corrupt. Suggested Solution: Export the
key(s) for the listed tape cartridge(s) again, and then perform the
import operation again.
• CRC Check Failed — Error. The CRC data does not match the key or
key metadata. The export file is corrupt. Suggested solution: Try to
import the same file again. If this fails, export the key(s) for the listed
tape cartridge(s) again, and then perform the import operation again.
• Import To Primary/Secondary Server Failed — Error. The key
import to the stated server failed (probably due to a network or other
connection issue). If the key failed to import to the secondary server,
it may have been imported successfully to the primary server.
Suggested solution: Check network connections and perform the
import operation again.
• Key Metadata Update Failed (but key data was imported
successfully) — Warning. The key was imported, but the metadata
update failed. You can access the key, but you cannot export it until it
is actually used in an encryption operation on the library. Suggested
solution: Use the key to read (decrypt) a tape. This marks the key as
“used” and updates the metadata, which will allow you to export the
key.
This log is only available if you are running SKM and have encryption
key management licensed on the library.
The log file is cleared and created new for each import operation so that it
shows only the key corruptions and import failures that occurred during
the latest encryption key import attempt.
The path to open the appropriate screen is as follows:
• From the Web client, select Reports > Log Viewer.

Scalar i500 User’s Guide

198

Chapter 7 Encryption Key Management
FIPS-Certified Encryption Solution

FIPS-Certified Encryption Solution
FIPS (Federal Information Processing Standard) 140-2 is a U.S.
government standard relating to computer security and encryption.
The Quantum Scalar i500 now offers a FIPS 140-2 Level 1 certified
encryption solution composed of the Scalar Key Manager and HP LTO-5
or LTO-6 Fibre Channel tape drives in a Scalar i500 library. FIPS mode
can be enabled on the HP LTO-5 or LTO-6 tape drives via the library user
interface. Once in FIPS mode, all encryption key communication between
the tape drive and the library controller is authenticated and encrypted.
Details about configuring FIPS mode include:
• Library firmware must be at version 600G or later.
• HP LTO-5 or LTO-6 FC tape drive firmware must be at the latest
version qualified with the Scalar i500 library (see the Scalar i500
Release Notes for qualified firmware levels).
• An Encryption Key Management license must be installed on the
library sufficient to cover the tape drive(s) on which you want to
enable FIPS mode.
• A Storage Networking license must be installed on the library
sufficient to cover the tape drive(s) on which you want to enable FIPS
mode.
• FIPS mode is configured by partition. FIPS partitions must contain
only HP LTO-5 FC or HP LTO-6 FC tape drives.
• The partition encryption method must be set to Enable Library
Managed in order to set FIPS mode.
• FIPS mode is disabled by default.
• Ethernet connectivity is required for the tape drives on which you
want to enable FIPS mode. For most libraries, this requires one or
more Ethernet Expansion blades installed on the library, unless your
library consists of a single 5U control module. For 5U libraries, you
can connect your tape drives directly to the Ethernet ports on the
library control blade (LCB). See Tape Drive Ethernet Connectivity
and the Ethernet Expansion Blade on page 458.

Scalar i500 User’s Guide

199

Chapter 7 Encryption Key Management
FIPS-Certified Encryption Solution

• The library must be connected to Scalar Key Manager. Scalar Key
Manager software must be at version 2.0 or later in order to be FIPS
certified.
Caution:

Configuring the Library
for FIPS
7

If the Ethernet Expansion blade fails and the attached
tape drives have FIPS mode enabled, all encryption
operations (encrypting, decrypting, key requests) on the
attached tape drives will fail. If this happens, contact
Quantum Support for a replacement Ethernet Expansion
blade as soon as possible.

To configure your library for FIPS, perform the following steps:
1 Upgrade library firmware to version 600G or later.
2 For all HP LTO-5 or LTO-6 FC tape drives that you plan to enable for
FIPS, upgrade firmware to the latest version qualified with the Scalar
i500 library (see the Scalar i500 Release Notes for qualified firmware
levels).
3 Shut down the library.
4 Do one of the following:

If your library is...

Do this...

5U

Perform Cabling a 5U Library for Ethernet
Connectivity on page 460.

14U or larger

Perform Cabling the Ethernet Expansion Blade
on page 468.
5 Power on the library.
6 Install Storage Networking and Encryption Key Management
licenses on the library, if they are not already installed.
7 Enable FIPS mode (see Enabling and Disabling FIPS Mode on HP
LTO-5 and LTO-6 Tape Drives on page 201).

Scalar i500 User’s Guide

200

Chapter 7 Encryption Key Management
FIPS-Certified Encryption Solution

Enabling and Disabling
FIPS Mode on HP LTO-5
and LTO-6 Tape Drives 7

To operate your HP LTO-5 or LTO-6 Fibre Channel tape drives to be
compliant with FIPS, you must enable “FIPS mode.” FIPS mode is
configured by partition. You enable FIPS mode on a partition, which
enables FIPS mode on all of the tape drives in the partition.
To change FIPS mode for a partition:
1 On the library web client, select Setup > Encryption > Partition
Configuration.
The Setup - Encryption Partition Configuration page displays (see
Figure 28 on page 201).
Change the Encryption Method of a partition to Enable Library
Managed.
2 Select the FIPS check box to enable FIPS mode for the partition. Clear
the FIPS check box to disable FIPS mode for the partition.
3 Click Apply.

Figure 28 Enabling FIPS Mode

Scalar i500 User’s Guide

201

Chapter 7 Encryption Key Management
FIPS-Certified Encryption Solution

Viewing FIPS Status on
the Library
7

There are three ways to view FIPS status on the library:
• The Partition Configuration screen (Setup > Encryption > Partition
Configuration) shows which partitions are enabled for FIPS. All tape
drives in FIPS partitions are enabled.
• The System Information Report (Reports > System Information)
contains a FIPS column in the Library Partitions section. The column
displays “Yes” if FIPS is enabled on the partition and “No” FIPS is
disabled.
• The tape drive information pop-up screen on the Library
Configuration Report (Reports > Library Configuration) contains a
FIPS Enabled item. This item only displays when the tape drive is an
HP LTO-5 or LTO-6 Fibre Channel tape drive. The item displays
“Yes” when FIPS is enabled on the drive and “No” when FIPS is
disabled.

Scalar i500 User’s Guide

202

Chapter 8

8

Extended Data Lifecycle
Management

Extended Data Lifecycle Management (EDLM) provides data protection
and integrity checking by scanning your tape cartridges, providing
results, and allowing StorNext® to migrate data from bad or suspect
tapes. EDLM allows you to run manual scans on any tape cartridge in the
library at any time, and performs automatic scans according to schedules
and policies that you set up.
To use EDLM, you will set up one or more dedicated partitions to be used
for scanning. These partitions are called “library managed” partitions
because they are not accessible by hosts. You can manually scan a tape
cartridge at any time, or you can set up automatic scanning schedules and
policies. Scanning takes place using “EDLM scanning drives” which are
different from regular tape drives. You cannot use regular tape drives to
perform EDLM scans.
This section covers the following topics:
• About EDLM on page 204
• Cleaning for EDLM Drives on page 207
• Incomplete EDLM Scans on page 207
• Configuring EDLM on page 207

Scalar i500 User’s Guide

•

Step 1: Preparing the Library on page 208

•

Step 2: Installing the EDLM Plug-in for SNAPI on page 208
(optional)

•

Step 3: Configuring the StorNext Host Settings on the Library on
page 211
203

Chapter 8 Extended Data Lifecycle Management
About EDLM

•

Step 4: Creating the EDLM Library Managed Partition on
page 213

•

Step 5: Setting Up Automatic EDLM Scanning Policies on
Partitions on page 216

• Pausing EDLM Scans on Partitions on page 222
• Running Manual EDLM Tests on page 224
• Working With EDLM Test Results on page 226
• Testing Suspect EDLM Drives on page 235

About EDLM
Details about EDLM are as follows:
• The EDLM feature requires an Extended Data Lifecycle Management
license to be installed on the library. One license covers the entire
library. See the Scalar i500 User’s Guide for instructions on how to
enable a license.
• Library firmware must be at code version 620G or later to use EDLM.
• You need Administrator privileges to configure EDLM and initiate
manual tests.
• At least one dedicated library managed partition is required for the
media scans. This library managed partition is accessible only by a
library administrator. It is not presented to any other applications.
The library managed partition is assigned its own dedicated
resources and EDLM scanning is executed in the background.
Cartridges are moved into EDLM-scanning drives residing in the
EDLM library managed partition. After being scanned, cartridges are
returned to their original locations. See Step 4: Creating the EDLM
Library Managed Partition on page 213.
• You can scan cartridges manually at any time. See Running Manual
EDLM Tests on page 224. You can also set up automatic media
scanning policies by partition. Each partition can have its own unique
set of media scanning and action policies. See Step 5: Setting Up
Automatic EDLM Scanning Policies on Partitions on page 216.

Scalar i500 User’s Guide

204

Chapter 8 Extended Data Lifecycle Management
About EDLM

• All types of tape cartridges (data, cleaning, diagnostic, and firmware
update tapes) can be scanned manually. However, only data
cartridges can be scanned automatically.
• If StorNext® Storage Manager is managing your partitions, you can
use it in conjunction with EDLM to automatically copy data off of
bad or suspect tapes or to trigger media scans. To use StorNext, you
must separately install a SNAPI client plug-in. See Step 2: Installing
the EDLM Plug-in for SNAPI on page 208.
• All media to be scanned must have a readable barcode label.
• All scans are performed in the order in which their requests were
received. If there are too many scans for the available tape drives,
scan requests are queued. Exception: Manual scans always go to the
top of the queue, regardless of when they are scheduled.
• A tape may only be scheduled once in the queue. For example, if a
tape is in the queue to be scanned per a particular policy, and a
different policy attempts to schedule it for scan later in the queue, the
scan requests will be combined and the tape will only be scanned
once, at the earlier time, and for the longest scan length (quick,
normal, or full).
• You cannot move media using the Operations > Media > Move
command to or from an EDLM library managed partition.
• You cannot delete the last remaining EDLM library managed
partition if a standard partition has automatic EDLM scan policies
enabled.
• The maximum number of records returned for an EDLM scan is 500.
Details about the EDLM library managed partition include:
• You can have multiple EDLM library managed partitions in the
library.
• All tape drives in the EDLM library managed partition must be
“EDLM-scanning drives” (not standard tape drives) which must be
purchased from Quantum. These EDLM-scanning drives are HP
LTO-4 Fibre Channel or HP LTO-5 Fibre Channel tape drives. You
can have both LTO-4 and LTO-5 EDLM-scanning drives in the same
EDLM library managed partition.
• An EDLM library managed partition can support any number of
EDLM-scanning drives (within the normal support of the physical
library).

Scalar i500 User’s Guide

205

Chapter 8 Extended Data Lifecycle Management
About EDLM

• All of the EDLM scanning drives in the EDLM library managed
partition must be connected to a Fibre Channel I/O blade. Each FC
I/O blade supports up to four tape drives. You can use multiple FC
I/O blades to support the EDLM-scanning drives. It is recommended
(although not required) that the FC I/O blade(s) used for EDLM
scanning drives have only EDLM scanning drives attached, and
recommended that the blade not be connected to a host. Otherwise,
the host will have access to the EDLM drives. For this reason, we
strongly discourage using the same FC I/O blade for EDLM drives
and host-connected 4 Gb/s SNW drives. If this must be done, the
FC I/O blade must be “channel zoned” to prevent host access to the
EDLM scanning drives.
• Tape drives in the EDLM library managed partition will only be used
for EDLM scanning purposes.
• An EDLM library managed partition can be composed of a mix of
licensed and unlicensed slots. Unlicensed slots will be used first, but
if the size of a newly configured EDLM partition exceeds the number
of available unlicensed slots, then the empty licensed slots will be
used.
• Standard tape drive cleaning policies apply to the tape drives in the
EDLM library managed partition.
• You can set up EDLM scanning policies on the EDLM library
managed partition.
• If you plan to use the EDLM partition to scan tapes encrypted using
library managed encryption, you will need to configure this partition
for library managed encryption, so that it can request the correct
encryption keys from the encryption key servers. Without the proper
encryption keys, the EDLM scanning drives cannot perform normal
or full scans on encrypted tapes. Select Setup > Encryption >
Partition Configuration.
Note:

When a partition is configured for Q-EKM, scan types of Normal and Full cannot be
selected.
• You cannot delete the last remaining EDLM partition if a standard
partition has EDLM policies enabled. To disable EDLM scanning
policies on a partition, select None for each of the following: Scan
upon import, Scan based on Tape Alert, and Use StorNext
configuration. In addition, set the normal and full scan time intervals
to zero. For more information, see Step 5: Setting Up Automatic
EDLM Scanning Policies on Partitions on page 216.

Scalar i500 User’s Guide

206

Chapter 8 Extended Data Lifecycle Management
Cleaning for EDLM Drives

Cleaning for EDLM Drives
Cleaning for EDLM drives must be done through the library's manual
cleaning feature or automatic cleaning feature. Simply inserting a
cleaning tape into an EDLM drive will not initiate cleaning because
EDLM drives are configured for a partial load, and the drive won't load
the tape to clean the drive.

Incomplete EDLM Scans
In rare cases, various operational issues could prevent an EDLM scan
from properly initiating. These instances will be indicated in individual
EDLM scan result details as “I/O Blade Component Failure.” This
message does not necessarily mean there are hardware issues with the
I/O blade or tape drive, but may indicate logical errors within
operational software for these components.
If these indications are observed within individual EDLM scan result
details, Quantum recommends power cycling I/O blades being utilized
for EDLM scans using the remote user interface's Setup > FC I/O Blade >
FC I/O Blade Control screen.
Please refer to the online help located on the Setup > FC I/O Blade > FC
I/O Blade Control screen for further details on power cycling FC I/O
blades.
Caution:

Configuring EDLM

8

If data drives are connected, make sure to stop any
running backups before power cycling blades.

Configuring EDLM consists of the following steps:
• Step 1: Preparing the Library on page 208
• Step 2: Installing the EDLM Plug-in for SNAPI on page 208

Scalar i500 User’s Guide

207

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

• Step 3: Configuring the StorNext Host Settings on the Library on
page 211
• Step 4: Creating the EDLM Library Managed Partition on page 213
• Step 5: Setting Up Automatic EDLM Scanning Policies on Partitions
on page 216

8

Step 1: Preparing the Library

1 Upgrade library firmware to at least version 620G. If needed, contact
Quantum Support to get the firmware.
2 Install EDLM-scanning drives in the library.
3 Connect each EDLM-scanning drive to one of the four initiator ports
in a Fibre Channel I/O blade. If you have more than four EDLMscanning drives, you will need to use more than one Fibre Channel
I/O blade.
4 Log on as an administrator.
5 Install the Extended Data Lifecycle Management license on the
library. See the Scalar i500 User’s Guide or online help for instructions.
6 Recommended: It is a good idea to create a “known good tape
cartridge” to have on hand in case you need to test an EDLM
scanning drive. A “known good tape cartridge” means one that is
fairly new, formatted, fully written, and that has a good cartridge
memory (CM). This tape will provide data that is easily verifiable to
help isolate media and drive issues.To purchase a “known good
tape” contact Quantum Technical Support. See Testing Suspect
EDLM Drives on page 235 for more information.
Note:

The default StorNext Storage Manager port number is
61776. If you changed the port on your server, be sure to
type the new port number into this field.

Step 2: Installing the EDLM Plug-in for SNAPI

8

This step is optional. If StorNext Storage Manager is managing your
partitions, you can use it in conjunction with EDLM to automatically
copy data from bad or suspect tapes or to trigger media scans. If you are
not using StorNext in conjunction with EDLM, skip this step.
Scalar i500 User’s Guide

208

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

In order to use StorNext for these purposes, you must first install the
StorNext application programming interface (SNAPI) client plug-in on
the library, and then configure the library to communicate with StorNext
Storage Manager. The EDLM plug-in for SNAPI is available from
Quantum.
To install the EDLM plug-in for SNAPI:
1 Confirm that the StorNext Storage Manager application managing
your partition is supported by the Scalar i500 firmware. For a list of
supported external applications and their corresponding plug-ins,
see the Scalar i500 Release Notes.
2 Download the correct EDLM plug-in for SNAPI bundle as follows:
a Go to the following Web site.
http://www.quantum.com/ServiceandSupport/SoftwareandD
ocumentationDownloads/SI500/Index.aspx
b

Click the Drivers tab to view the available plug-ins.

c

Click the Download button for the plug-in you want to install.
Download the file to an accessible location on your computer.

The plug-in bundle is a .zip file containing the following files:
•

Client plug-in

•

End User/Open Source License Agreement

3 Extract the files from the .zip file.
4 Read the End User/Open Source License Agreement. Installation of
the plug-in implies acceptance of the license agreement.
5 From the library Web client, select Tools > EDLM > Manage Plugins.
6 The Tools - Manage EDLM Plug-ins screen appears.

Scalar i500 User’s Guide

209

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Figure 29 Installing the SNAPI
Plug-in

7 Click Install.
The Tools - Manage EDLM Plug-ins screen appears.

Figure 30 Installing the SNAPI
Plug-in

8 Click Browse to navigate to and select the EDLM plug-in for SNAPI
you downloaded earlier.
9 Click Next.
A confirmation screen appears.

Scalar i500 User’s Guide

210

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

10 Click Install.
The file is installed. When complete, a Success message appears.
11 Click Close to close the Success message.
Step 3: Configuring the StorNext Host Settings on the Library

8

This step is optional. If StorNext Storage Manager is managing your
partitions, you can use it in conjunction with EDLM to automatically
copy data from bad or suspect tapes or to trigger media scans. If you are
not using StorNext in conjunction with EDLM, skip this step.
After installing the SNAPI client plug-in, you must configure the library
to communicate with the StorNext Storage Manager host server.
1 From the Web client, select Tools > EDLM > Configure StorNext
Settings.
The Tools - EDLM StorNext Configuration screen appears.
2 Click Create.
The Tools - EDLM StorNext Configuration entry screen appears.

Figure 31 StorNext Host
Configuration

Scalar i500 User’s Guide

211

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

3 In the Name field, type a name that you will use to identify the
StorNext Storage Manager server.
4 From the API Client Plug-in drop-down list, select the SNAPI client
plug-in.
5 From the Primary Host Address field, type the IP address (or host
name, if DNS is configured) of the primary StorNext Storage
Manager server.
6 From the Primary Host Port field, accept the default or type the port
number of the primary StorNext Storage Manager server.
Note:

The default StorNext Storage Manager port number is
61776. If you changed the port on your server, be sure to
type the new port number into this field.

7 Optionally, type an IP address (or host name, if DNS is configured)
for a secondary StorNext Storage Manager server in the Secondary
Host Address field.
8 Optionally, accept the default or type a port number of a secondary
StorNext Storage Manager server in the Secondary Host Port field.
Note:

The default StorNext Storage Manager port number is
61776. If you changed the port on your server, be sure to
type the new port number into this field.

9 Click Apply.
The settings are configured. When complete, a Success message
appears.
10 Click Close to close the Success message.
The main screen appears again with the server you just entered listed.
There is a Run button in the Diagnostics column.
11 Click the Run button to test the settings you configured. If a Failed
message appears, you can click the Failed link and a message box
appears to help you troubleshoot. Make sure the IP addresses and
port numbers you entered are correct, and that the plug-in is
supported.

Scalar i500 User’s Guide

212

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Figure 32 Testing the StorNext
Settings
Failed message/link

Troubleshooting text box

12 Once you have successfully configured StorNext host settings, you
can configure StorNext-related EDLM policies on partitions as
described in Chapter 8, Step 5: Setting Up Automatic EDLM
Scanning Policies on Partitions.
Step 4: Creating the EDLM Library Managed Partition

8

The EDLM library managed partition is a dedicated partition that you set
up in the library for scanning media with EDLM. This partition exists
solely for media scanning purposes and is not accessible to hosts or other
applications. Tape cartridges are moved into the EDLM library managed
partition and scanned using the tape drives residing in the EDLM library
managed partition. When the scan is complete, the cartridges are
returned to their original partitions.

Scalar i500 User’s Guide

213

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Note:

If you plan to use this EDLM partition to scan tapes encrypted
using library managed encryption, you will also need to
configure this partition for library managed encryption, so
that it can request the correct encryption keys from the
encryption key servers. Without the proper encryption keys,
the EDLM scanning drives cannot perform normal or full
scans on encrypted tapes. Once you have created the partition,
select Setup > Encryption > Partition Configuration and
configure the partition for library managed encryption.

To create the EDLM library managed partition, do the following:
1 From the Web client, select Setup > Partitions.
2 Click Create.
The Create Partition - Basic Settings screen appears (see Figure 33).

Figure 33 Creating EDLM
Partitions

3 From the Select Partition Type drop-down list, choose Library
Managed (EDLM).
Scalar i500 User’s Guide

214

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

4 Type a name for the partition in the Enter Name text box.
5 Type in the number of storage slots to assign to the partition in the
Enter Number of Slots text box.
Note:

The number in parentheses indicates the number of slots
available for use in the partition. For standard partitions,
the number equals the number of licensed slots available,
and the default equals the total number of available slots.
Since EDLM partitions can contain both unlicensed and
licensed slots (using all unlicensed slots before using
licensed slots), the number in parentheses equals the total
number of licensed and unlicensed slots, and the default
equals the number of unlicensed slots available. You can
configure EDLM partitions to use zero slots if desired.

Note:

The Select Emulation Type and Select Media Barcode
Format fields are not selectable when creating EDLM
library managed partitions.

6 Select the drive(s) you want to add to the partition from the table.
Only EDLM scanning drives appear in the list.
7 Click Next.
The Create Partition - EDLM Policy Settings screen appears (see
Figure 34 on page 217).
8 If desired, set EDLM scanning policies on this EDLM library
managed partition (go to Step 5: Setting Up Automatic EDLM
Scanning Policies on Partitions on page 216).
9 If you do not wish to configure automatic EDLM scanning policies on
the partition, click Apply to finish.

Scalar i500 User’s Guide

215

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Step 5: Setting Up Automatic EDLM Scanning Policies on Partitions8
You can set EDLM scanning policies on both standard partitions and on
EDLM library managed partitions. Once configured, scanning takes place
automatically per the policies. You can temporarily stop automatic scans
on partitions by using the Pause feature (see Pausing EDLM Scans on
Partitions on page 222).
1 Log on as an administrator.
2 From the Web client, select Setup > Partitions.
3 Click Create to create a new partition, or select a partition and click
Modify to modify an existing partition.
4 When finished configuring the general settings, click Next.
The Create Partition - EDLM Policy Settings screen appears (see
Figure 34 and Figure 35).
Note:

Scalar i500 User’s Guide

Fewer policies are available on EDLM library managed
partitions because they are inaccessible to hosts.

216

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Figure 34 EDLM Policy
Settings for EDLM Library
Managed Partitions

Scalar i500 User’s Guide

217

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Figure 35 EDLM Policy
Settings for Standard Partitions

5 Set EDLM scanning policies on this partition. Table 8 describes the
policies that you can set.

Scalar i500 User’s Guide

218

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Note:

To disable EDLM scanning policies on a partition, select
None for each of the following: Scan upon import, Scan
based on Tape Alert, and Use StorNext configuration. In
addition, set the normal and full scan time intervals to
zero.

Table 8 EDLM Policy Settings
for Partitions

Setting

Description

General Settings
Allow concurrent scans

Select the number of tape drives that this partition can use for EDLM scans
at any one time. If you have several partitions that will use EDLM scanning
drives, you can use this feature to divide the EDLM drive resources so that
a single partition with a large number of scans to perform can never “hog”
all of the resources and prevent other partitions from performing their
scans in a timely manner.
Choices are: Unlimited (default), 1, 2, 3, or 4. “Unlimited” means that this
partition can use all available EDLM scanning drives concurrently.

Report media
inaccessible

When this check box is de-selected (default), if a host requests a tape
cartridge that is being scanned, the scan is cancelled and the tape cartridge
is moved back to its original location to service the host request. The
interrupted scan is not rescheduled. The EDLM report indicates the
interruption or cancellation. This ensures that normal operations are not
affected by EDLM scanning.
When this check box is selected, if a host requests a tape cartridge while it
is being scanned, the library responds to the host that the tape cartridge is
inaccessible.
Note:

Scalar i500 User’s Guide

This feature is currently disabled. The library always reports
media accessible to hosts (i.e., the box is de-selected and cannot be
selected).

219

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Setting

Description

Use StorNext
Configuration

Select whether to use StorNext in conjunction with EDLM to perform
certain EDLM operations; and, if so, which StorNext configuration to use.
From the drop-down list, select None (default) or select one of the
StorNext configurations you set up in Step 3: Configuring the StorNext
Host Settings on the Library on page 211.

Scan Settings
Scan upon import

Choose whether to scan tapes as soon as they are imported into this
partition; and, if so, which type of scan to perform. This policy is disabled
by default.
Choices are:
• None (default) — Does not scan upon import.
• Quick — Does not scan the tape. Evaluates data from the cartridge
memory (CM) only. Takes less than one minute per tape. Examples of
when to use a quick scan:
• When you first import previously used scratch tapes into the library.
• When you import data cartridges that have been used in other backup
and archival environments and need to do a quick check to determine
whether the tape cartridge is nearing end of life, at end of life, or may
have had issues reading or writing.
• Normal — Evaluates the cartridge memory (CM) and scans selected
portions of the tape, focusing on areas most likely to indicate problems.
Takes up to 20 minutes per tape. Examples of when to use a normal
scan:
• For tapes in frequent use within the library, with scanning triggered
by drive-reported media Tape Alert events.
• For tapes in frequent use within the library, with scanning being
performed at regular time intervals.
• Full — Evaluates the cartridge memory (CM) and scans the entire tape.
Can take more than 2 hours on a full tape. Example of when to use a full
scan:
• When tape cartridges are accessed infrequently and are used primarily
for on site or offsite long-term data retention.
• When tape cartridges with valuable data are introduced into the
library and the state and condition of the tapes are unknown.

Scalar i500 User’s Guide

220

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Setting

Description

Scan based on Tape
Alert

Choose whether to scan tapes based on Tape Alert count; and, if so, which
type of scan to perform (Quick, Normal, or Full, described above). Select
None to disable this policy. This policy is disabled by default.
When enabled, a tape will be scanned if the number of Tape Alerts
reported for that cartridge exceeds the user-specified value in the Tape
Alert count field, described in more detail below.
The Tape Alerts included in the count are:
• 01h (1)– Read Warning
• 03h (3) – Hard Error
• 04h (4) – Media
• 05h (5) – Read Failure
• 06h (6) – Write Failure
• 12h (18) – Tape Directory Corrupted on Load
• 33h (51) – Tape Directory Invalid on Unload
• 34h (52) – Tape System Area Write Error
• 35h (53) – Tape System Area Read Error
• 37h (55) – Loading Failure
• 3Bh (59) – WORM Medium Integrity Check Failed

Tape Alert count

Use this field in conjunction with the Scan based on Tape Alert policy.
From the drop-down list, select the number of Tape Alerts allowed before
a scan is performed.

Normal scan time
interval

Scans a tape if the listed time interval since the last scan was performed has
been exceeded. In the text box, type a time interval (in days) after which a
scan will be performed. A value of zero (default) means the this policy is
disabled.

Full scan time
interval

Scalar i500 User’s Guide

Note:

When deciding the interval, consider the number of tapes to be
scanned in the entire library, as well as the type of scan to be
performed. Full scans can take more than 2 hours on full tapes.
Over-scheduling can cause delays or cause tapes not to be scanned
as intended.

221

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Setting

Description

Scan based on StorNext
media suspect count

Only available if you selected Use StorNext Configuration above.
The suspect count is a means by which StorNext Storage Manager
determines when to stop writing data to tape.
If you select this policy, a tape will be queued for EDLM testing when its
suspect count threshold is reached. If the EDLM test indicates the tape is
good, you can reset the suspect count on the StorNext application and
continue to use the tape. For more information on suspect counts and
resetting suspect counts, refer to your StorNext application’s
documentation.

Result Action Settings
Disable RAS ticket for
bad or suspect media

Select this check box if you wish to disable summary RAS tickets and RAS
ticket e-mail notifications stating media is bad or suspect media based on
the results of EDLM scans. By default, these summary RAS tickets are
disabled (i.e., this check box is selected), because this information is
available from the EDLM test results.
Note:

Initiate StorNext copy
operation for

RAS tickets for specific drive and media issues found during
EDLM scans will never be disabled. Only the summary results
tickets and notifications (stating media is suspect or bad) can be
enabled or disabled.

Only available if you selected Use StorNext Configuration above.
Automatically requests StorNext Storage Manager to copy all data from a
bad and/or suspect tape to another tape. From the drop-down list, you can
choose to copy bad tapes, suspect tapes, or both. You can also choose
Disabled, which disables the policy. This policy is disabled by default.
A RAS ticket will be generated for each request to copy data indicating
whether the request succeeds or fails.
6 Click Apply to finish.

Pausing EDLM Scans
on Partitions

Scalar i500 User’s Guide

8

You can temporarily halt EDLM scanning in a partition but keep your
EDLM policy selections intact so that you can re-enable them later. You
might want to do this if you suspect a problem (for example, if it seems
that too many tapes are being scanned, and library operations are being
affected).
222

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

When you pause EDLM scans, tapes that are currently being scanned
finish their scans, are unloaded from the tape drives, and are moved back
to their original locations. No further tapes are scanned. Tapes in the
queue remain queued. Once unpaused, tapes that would have been
queued during the pause period are queued and scans resume as normal.
To pause automatic scanning, you must change the EDLM mode on a
partition, as follows:
1 Log on as an administrator.
2 From the Web client, select Operations > Partitions > Change Mode.
The Change Partition Mode screen appears.

3 Under EDLM Mode, the Current column displays one of the
following:
•

Not Configured — EDLM policies have not been configured on
the partition.

•

Active — EDLM policies are configured and running.

•

Paused — EDLM scanning is paused.

The New column contains an Active/Paused button. The button
toggles between modes.

Scalar i500 User’s Guide

223

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

4 To change the mode from Active to Paused or from Paused to Active,
click the button in the New column, and then click Apply.
The operation completes and, if successful, a Success message
appears.
5 Click Close to close the Success message.

Running Manual EDLM
Tests
8

You may wish to evaluate media outside of the automatic EDLM
scanning policies. To do this, you can run a manual EDLM scan. Manual
scans are given highest priority and go to the top of the scanning queue.
As soon as an EDLM scanning drive has finished its current scan, it will
accept the tape scheduled for a manual scan. Once all manual scans are
finished, the scan queue continues as normal.
Manual EDLM scans can be run on any tape in the library, as long the
following conditions are met:
• An EDLM license must be installed on the library.
• The EDLM library managed partition must be configured on the
library (see Step 4: Creating the EDLM Library Managed Partition on
page 213).
• The cartridge you want to scan must be readable by a tape drive in
the EDLM library managed partition per standard LTO-gen-based
backwards-compatibility limitations.
• The cartridge you want to scan must be labeled properly. Unlabeled
media cannot be selected for manual scans.
• The cartridge can be located in any partition, including the EDLM
library managed partition. However, the cartridge must not be
located in an EDLM drive.
• If a tape is currently being scanned, you cannot select it for manual
scanning.
To run a manual EDLM test, do the following:
1 Log on as an administrator.
2 Select Tools > EDLM > Test Selection.
The Tools - EDLM Test Selection screen appears.

Scalar i500 User’s Guide

224

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

3 From the Partition drop-down list, choose the partition that contains
the tape(s) you want to scan.
4 From the Scan type drop-down list, choose the type of scan to
perform (Quick, Normal, or Full). The default is Normal. For a
description of these scan types, see the Scan Settings section of
Table 8 on page 219.
5 If you want the test to continue on error, select the Continue On
Error check box. By default, during normal and full scans, a cartridge
memory (CM) test is performed first. If that fails, the rest of the scan
(the tape test) is skipped and the test fails. When you select Continue
On Error, the tape test is performed even if the CM test fails.
6 Select the tape(s) to scan from the table. To select all tapes listed,
select the check box at the top of the check box column. To filter the
displayed list, enter a barcode or portion of a barcode in the Filter by
barcode field and click Find.

Scalar i500 User’s Guide

225

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Note:

If you select a tape that is not supported by the EDLM
scanning drives, once you click Apply, a dialog box
message will appear stating, “You have selected to scan
media that may not be supported by any of the EDLM
drives installed in the library. If you continue, these scans
may not complete successfully. Are you sure you want to
do this?” If you continue, the tape will be queued for scan,
but may fail.

7 Click Apply.
The test is queued. Once the test is queued, a Success message
appears. This does not mean the test was run or that the tape passed
the test, it just means that the test is queued.
Note:

Even though manually scheduled tests move directly to
the top of the queue, it is possible that the tape will not be
tested right away (if all EDLM drives are currently in the
process of scanning tapes, they will finish their current
scans before becoming available to perform the manually
scheduled test).

8 Click Close to close the Success message.
9 To view the test results, select Tools > EDLM > Test Results (see
Working With EDLM Test Results on page 226).

Working With EDLM
Test Results

8

You can view the status of all your EDLM test sessions, including
sessions that are queued but not started yet, in the EDLM Test Sessions
List screen. You can stop, pause, resume, or delete test sessions. See
Working with the EDLM Test Sessions List on page 227.
Each entry in the EDLM Test Sessions List screen presents an overview of
a single EDLM test session. A test session includes all tapes in the library
that were scheduled to be scanned at a particular point in time. Thus, a
test session can include multiple tapes from different partitions.
• Example 1: You select 10 tapes on which to perform a manual scan.
The test session includes 10 tapes.

Scalar i500 User’s Guide

226

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

• Example 2: Partition A has an automatic scan policy to scan tapes on
import. You import a tape. Meanwhile, Partition B has an automatic
scan policy to scan every 180 days. Ten tapes in that partition have
reached the 180-day mark at the same time that you import the tape
into Partition A. Because these automatic scans occur at the same
time, the test session includes all 11 tapes from both partitions.
Within each test session, you view details about each tape that was
scanned (see Viewing EDLM Session Report Details on page 229).

8

Working with the EDLM Test Sessions List
To view the status of EDLM test sessions (both automatic and manual),
do the following:
1 Log on as an administrator.
2 From the Web client, select Tools > EDLM > Test Results.
The Tools - EDLM Test Results screen appears.

Scalar i500 User’s Guide

227

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

The table displays the set of media tests that have run based on the
time range selected. Each row in the table presents an overview of a
single EDLM test session. The table displays the following
information about the test sessions:

Item

Description

Session ID

The session identifier, a unique number assigned to each test session that was
run.

State

Pending, Complete, In Progress, Stopped, or Paused.

Start Time

The date and time the test session was started.

Finish Time

The date and time the test session completed.

Results

A summary of results for all media tested in the session. The reported values
include the number of tapes scanned (in parentheses) for each result obtained.
Note: To view results for individual tapes in the session, select a test session
row and then click the Details button.
Results are the following:
• Good — The tape is good.
• Bad — The tape is bad.
• Suspect — The tape is possibly unreliable or defective.
• Untested— The tape could not be fully scanned, for various reasons,
including: incompatible media; cartridge could not be loaded; tape is
encrypted but the data encryption key could not be obtained; drive not
communicating with I/O blade, test was stopped.
Note: Untested media do not initiate RAS tickets or EDLM media action
policies (such as copying data from a bad or suspect tape).
• Not Completed — The test has not completed yet.
3 From the Select Time Range drop-down list, select the range of time
for test sessions that you want displayed. The time range is based on
the start time of the test session. Choose one of the following:
• Last Day — Test sessions that were run in the last 24 hours.
• Last Week — Test sessions that were run in the last seven days.
• Last Month — Test sessions that were run in the last month.

Scalar i500 User’s Guide

228

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

• All — All test sessions that were run on the library. The storage limit
is 5,000 media scans. When the limit is reached, old scan results are
deleted as new scan results are added.
4 To work with a session, select a test session row and then click your
desired option:

Option

Description

Stop

Stops a currently running test session. Once stopped, you cannot restart the
test session. Any test results collected so far are listed. Tapes that did not
complete testing as a result of being stopped show a test result of Untested.

Pause

Pauses a currently running test session. If a tape is currently being scanned, the
scan will finish and the tape will be ejected and moved back to its original
location. Tapes in the test session that have not been tested yet will remain
queued.

Resume

Resumes a paused test session. Queued tapes are mounted and scanned.

Details

Displays the test report for the selected test session in a new window. See
Viewing EDLM Session Report Details on page 229.

Delete

Deletes the selected test session from the list. Once deleted, you cannot retrieve
the information again.

Viewing EDLM Session Report Details

8

To view details about a specific EDLM test session, do the following:
1 Go to the EDLM Test Results screen (Tools > EDLM > Test Results).
2 Select a row and then click the Details button.

Scalar i500 User’s Guide

229

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

The test results display in a new window.

Scalar i500 User’s Guide

230

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

The top section of the screen lists each tape in the test session. The
following information is reported:

Item

Description

Barcode

The media barcode identifier.

Test Result

The test result displays as one of the following:
• Good — The tape is good.
• Bad — The tape is bad.
• Suspect — The tape is possibly unreliable or defective.
• Untested — The tape could not be fully scanned, for various reasons,
including: incompatible media; tape could not be loaded; tape is encrypted
but the data encryption key could not be obtained; drive not communicating
with I/O blade, test was stopped.
Note: Untested media do not initiate RAS tickets or StorNext copy
operations.
• Not Completed — Test has not completed yet.

Scan Type

The type of test that was run: Quick, Normal, or Full.

Drive ID

The physical serial number of the tape drive that tested the tape.

Partition

The partition that the tape(s) being tested in the session belong to.

State

The current test status: Pending, In Progress, Completed, Stopped or Paused.

Completed

The date and time the test completed.
3 To view test details for a specific tape, select a row in the top section.
Details about the test results display in the area below the table. The
following details display:

Scalar i500 User’s Guide

231

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Item

Description

CM Scan Status

One of the following:
• Complete — Test is finished; however, the result may not be “good.” You
can also get this if the test was stopped. For details, see the CM Scan
Analysis.
• Paused
• Pending
• Not Run — For details see the CM Scan Analysis
• In Progress
• Stopped

CM Scan
Analysis

One of the following:
• Good
• N/A
• Failed to receive CM data
• CM hardware failure
• Tape reached 99% of the manufacturer defined number of tape
thread/load operations
• Tape reached 99% of the manufacturer defined number of full tape
capacity write operations
• CM indicates uncorrected errors on the tape
• Unable to load tape
• Unable to unload tape
• Tape not present
• No compatible drive
• I/O Blade Component Failure

Scalar i500 User’s Guide

232

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Item

Description

Tape Scan Status

One of the following:
• Complete — Test is finished; however, the result may not be “good.” For
details see the CM Scan Analysis.
• Paused
• Pending
• Not Run — For details, see the CM Scan Analysis.
• In Progress
• Not Configured — You requested a Quick Scan only so the tape was not
scanned.
• Stopped

Scalar i500 User’s Guide

233

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

Item

Description

Tape Scan
Analysis

One of the following:
• Good
• N/A
• I/O Blade Component Failure
• Failed to retrieve scan data
• Unexpected EOD. Possibly corrupt CM
• Unformatted tape
• Failed to read tape data
• Un-recovered read errors on the tape
• Corrupt data format
• Tape experienced a mechanical error
• Tape performance is severely degraded
• Unable to load tape
• Unable to unload tape
• Tape is a cleaning cartridge
• CM fault detected
• Unknown media type detected
• Scan operation interrupted and ended
• Drive does not report media presence
• Tape is encrypted
• Tape is blank
• Block size exceeds maximum
• Tape is a FUP tape
• Drive CM read failed

Scalar i500 User’s Guide

234

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

4 To send a copy of the test session report via e-mail, type an address in
the Send field and click the Send button.
Note:

In order to send an e-mail, e-mail notifications must be set
up on the library (Setup > Notifications > E-mail
Configuration).

5 To update the screen with the current status, click Refresh.

Testing Suspect EDLM
Drives
8

If an EDLM drive reports a suspicious number of errors within a given
time period, it will be taken offline and not used for testing until brought
back online manually. This operation allows testing the drive with a
known-good tape cartridge to determine whether the problems detected
by the drive are legitimate, or possibly due to a problem with the drive
itself. If this occurs, the library will issue a RAS ticket directing you to test
the tape drive.
To test the drive:
1 Select Tools > Drive Operations.
The Tools - Drive Operations screen opens.

Scalar i500 User’s Guide

235

Chapter 8 Extended Data Lifecycle Management
Incomplete EDLM Scans

2 Select Perform EDLM Drive Test and click Next.
The EDLM Drive Test screen appears.

3 Place a known good tape cartridge into the top I/E station slot.
Note:

A “known good tape cartridge” means one that is fairly
new, formatted, fully written, and that has a good
cartridge memory (CM). It is a good idea to create one to
have on hand for this type of operation.

4 Select the drive to test and click Apply.
The tape is tested using the known good tape cartridge. When the test
completes, a Success or Failure message appears.
5 Do one of the following:

Scalar i500 User’s Guide

•

If the result is Success — Manually bring the tape drive back
online (Tools > Drives > Change Mode).

•

If the result is Failure — If you used a known good tape, a
failure generally means the drive has failed. View the RAS ticket
details or contact Quantum Support for further analysis.

236

Chapter 9

9

Running Your Library

This chapter explains how to access and operate your library. Most of the
library functions described here can be found on the Operations menu.
Note:

The information in this chapter assumes you are using the
Web client. Differences in functionality between the Web
client and the operator panel are noted.

This chapter covers:
• Powering on the Library
• Shutting Down, Powering Off, and Completely Removing Power
• Restarting the Library
• Logging In
• Logging Out
• Performing Media Operations
• About Cleaning Tape Drives
• About Tape Drive Operations
• Locking and Unlocking the I/E Stations
• Controlling FC I/O Blade Power

Scalar i500 User’s Guide

237

Chapter 9 Running Your Library
Powering on the Library

Powering on the Library
To power on the library:
1 Connect all power cords to their electrical source.
2 Turn on each power supply using the switch on the rear of the power
supply.
3 Press the power button located on the front door of the library’s
control module.
When you power on the library, the library performs a self-test to ensure
that all of its parts are functioning properly. All tape drives and partitions
are brought online.

Shutting Down, Powering Off, and Completely Removing
Power
The Shutdown command shuts down the library’s operating system and
firmware. When performing a shutdown, the library finishes the current
command and lowers the robot to the floor of the library.
Caution:

Always perform a shutdown before powering off the
library or completely removing power from the library.

Before performing a shutdown, make sure the connected host
applications are not sending commands to the library.
To power off the library: Perform the shutdown sequence and then press

the power button on the front of the control module.

To completely remove power: Perform the shutdown sequence and power
off the library. Then turn off the power switch on each power supply,
located at the rear of the library. Finally, disconnect the power supply
cables from their electrical source.

Scalar i500 User’s Guide

238

Chapter 9 Running Your Library
Restarting the Library

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > System Shutdown.
• From the operator panel, select Operations > Shutdown.

Restarting the Library
The Restart command shuts down and restarts the library’s operating
system and firmware. When performing a restart, the library finishes the
current command, then shuts down the library and restarts it. During the
restart, the library brings all tape drives and partitions online and
performs an inventory of cartridges, tape drives, and slots.
Before performing a restart, make sure the connected host applications
are not sending commands to the library.
Restarting takes approximately 5 minutes for the control module and
longer for the 14U and higher library configurations.
If the “Not Initialized” message appears on the operator panel after the
restart process is complete, the library did not properly initialize. View
the All RAS Tickets screen to find the problem that is preventing the
library from properly initializing. See Viewing RAS Tickets on page 482.
The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > System Shutdown.
• From the operator panel, select Operations > Shutdown.

Logging In
All users, service users, and administrators must log in to the library to
perform library functions or view library operations.

Scalar i500 User’s Guide

239

Chapter 9 Running Your Library
Logging Out

If you are logging in to the library for the first time using the default
administrator account, type admin in the User Name text box and
password in the Password text box.
After you log on for the first time, change the password for the default
administrator account. Passwords are limited to 6–16 lower-case
alphanumeric characters and can also include underscores (_), periods (.),
hyphens (-), asterisks (*), and and the “at” symbol (@). For example:
pass_1. For information on changing passwords, see Modifying Local
User Accounts on page 98.
Note:

Logging In When LDAP
or Kerberos is Enabled 9

If you misplace the password for the default administrator
account, contact Quantum Technical Support. For contact
information, see Getting More Information or Help on page 8.

When LDAP or Kerberos is enabled, the Login screen displays a Remote
Authentication check box. Log in on either the operator panel or Web
client as follows:
• Select the Remote Authentication check box to log in using a directory
service user name and password.
• Clear the Remote Authentication check box to log in using a local user
name and password.
For more information on LDAP, see Configuring LDAP on page 99.
For more information on Kerberos, see Configuring Kerberos on
page 104.

Logging Out
Logging out secures the library from being accessed by unauthorized
users. Log out whenever you have finished accessing the library through
either the Web client or the operator panel.
From the Web client or the operator panel, you can click the LOGOUT
button at the top right of the screen to log out. From the Web client, you
can also select Operations > Logout.
Scalar i500 User’s Guide

240

Chapter 9 Running Your Library
Performing Media Operations

Performing Media Operations
Administrators and users can use commands on the Web client and
operator panel Operations menu to perform the following media
operations:
• Import data cartridges into the library
• Export data cartridges from the library
• Move data cartridges between tape drives, I/E stations, and storage
slots within a partition
• Import cleaning cartridges into the library (AutoClean is enabled)
• Export cleaning cartridges from the library (AutoClean is enabled)
• Load cartridges into tape drives
• Unload cartridges from tape drives
• Change the tape drive mode from online to offline and back as
needed
In addition, administrators can:
• Clean tape drives manually, using the Tools > Drive Mgmt > Clean
Drive command on the operator panel or Tools > Drive Operations >
Clean a tape drive from the Web client.
The following topics provide an overview of these media operations. For
step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel.
Note:

Scalar i500 User’s Guide

The information and procedures in this user’s guide apply
specifically to the library Web client and the operator panel
user interface, not to the host application. Performing media
operations through the library user interface may affect your
host application. See your host application documentation for
information.

241

Chapter 9 Running Your Library
Performing Media Operations

Importing Media

9

The Import Media operation allows you to use the I/E station to import
data cartridges into the library. The library’s scanner automatically reads
the barcode on new cartridges imported into the library.
Note:

If your library has zero I/E station slots, you cannot import or
export media. See Configuring I/E Station Slots on page 79.

This topic focuses on using the library user interface, not the host
application, to import media. Using the library to import media may
necessitate performing an inventory of the library with the host
application. See your host application documentation for more
information.
There are two ways to import tape cartridges via the library: with manual
cartridge assignment enabled or disabled. Manual cartridge assignment
is enabled on the library by default. For information on
disabling/enabling this feature, see Disabling/Enabling Manual
Cartridge Assignment on page 77.
This section contains the following sub-sections
• Importing Media with Manual Cartridge Assignment Enabled on
page 243
• Importing with Manual Cartridge Assignment Disabled on page 244
• Process for Importing Media on page 244

Scalar i500 User’s Guide

242

Chapter 9 Running Your Library
Performing Media Operations

The table below describes the differences in what you can do depending
on manual cartridge assignment status:
Manual
Cartridge
Assignment
Enabled

(default)

Disabled

Cartridge Assignment in I/E
Station
You are asked to assign cartridges
to a partition immediately upon
placing them in the I/E station. You
may “cancel” out of this window
without assigning them to a
partition.
You are not asked to assign
cartridges to a partition and the
cartridges remain unassigned until
imported into the library.

Is Importing
Unassigned Media
Allowed?
From operator panel:
NO

From Web client:
YES

From operator panel:
YES

From Web client:
YES

9

Importing Media with Manual Cartridge Assignment Enabled

• When Manual Cartridge Assignment is enabled (default), once you
load tape cartridges into the I/E station and close the I/E station
door, the Assign I/E screen automatically appears on the operator
panel. The Assign I/E screen prompts you to use the operator panel to
assign the cartridges to a specific partition or to the system partition.
The cartridges can be used only by the assigned partition. All of the
cartridges you placed in the I/E station are assigned to the same
partition that you selected.
• If you cancel out of the Assign I/E screen (or forget to assign the
inserted cartridge to a partition), the cartridges remain unassigned
until you either import them via the Web UI or open and close the
I/E station so the Assign I/E screen displays again.
• You cannot import unassigned media into the library via the operator
panel.
• You can import unassigned media into the library via the Web client.
When importing cartridges via the Web client, all unassigned
cartridges in the I/E station will be assigned to the same partition.
However, only the cartridges you select will actually be moved into
the library storage slots. The non-selected cartridges will remain in

Scalar i500 User’s Guide

243

Chapter 9 Running Your Library
Performing Media Operations

the I/E station assigned to that partition until you import them into
that partition. To import a previously assigned cartridge into a
different partition, you must first remove that cartridge from the I/E
station, place it in a different I/E station slot, and then import it into
the desired partition.
• Unassigned cartridges are not visible to host applications.

9

Importing with Manual Cartridge Assignment Disabled
• Disabling manual cartridge assignment allows you to load several
tape cartridges into the I/E station and assign them to different
partitions.

• The Assign I/E screen does not appear on the operator panel. The
cartridges in the I/E station are available for use by any partition,
including the system partition. The cartridges in the I/E station
remain unassigned until you import them into a partition (importing
assigns them to the partition).
• You can import unassigned tape cartridges via the operator panel or
the Web client. When importing unassigned tape cartridges, only the
cartridges you actually import into a partition will be assigned to that
partition. The rest of the cartridges will remain unassigned in the I/E
station.
• Unassigned cartridges are visible to host applications and can be
claimed by any host application on a first-come, first-served basis.

9

Process for Importing Media
You must have access to the library’s I/E station and the operator panel
to import cartridges.

If you have AutoClean enabled, you can also import cleaning cartridges
into the library. For information, see Importing Cleaning Media on
page 256. In addition, you can bulk load cartridges into the library rather
than use the I/E station to import media. For information, see Bulk
Loading on page 246.
Note:

Scalar i500 User’s Guide

Once the import operation has started, do not interfere with
the operation by opening and closing the I/E station door.

244

Chapter 9 Running Your Library
Performing Media Operations

The process for importing cartridges includes the following steps:
1 Go to the front of the library and insert cartridges into the I/E station.
2 Close the I/E station door.
The Assign I/E screen appears on the operator panel if the Manual
Cartridge Assignment setting is enabled on the operator panel System
Settings screen (Tools > System Settings).
If the Assign I/E screen appears, do the following:
a Assign the cartridges to the appropriate partition by selecting a
partition listed on the Assign I/E screen.
The partition button turns red after it has been selected.
Caution:

b

If you select the wrong partition, open the I/E station
door. Move the cartridge to a different I/E station slot
and close the I/E station door. The library will rescan
the I/E station, and the Assign I/E screen will appear
again.

Select Apply.
If the selected partition is online, it will be taken offline before the
import operation is performed, and brought back online after the
operation is complete. If the library contains multiple partitions,
the import operation will not affect operations in other partitions.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

3 Use the Import Media screens on either the operator panel or the Web
client to import the cartridges into the partition. Follow the on-screen
prompts, or see the library’s online Help for step-by-step procedures.
To access the online Help system, click the Help icon at the top right
of the Web client or operator panel user interface.
You need to provide the following information in the Import Media
screens to import media:

Scalar i500 User’s Guide

245

Chapter 9 Running Your Library
Performing Media Operations

•

Partition — The partition into which you want to import the

•

Media — The cartridges that you want to import.

cartridges. The screen lists only the partitions to which you have
been given access. The screen includes information about the
partition mode (online or offline) and the number of empty slots
in the partition. The number of cartridges you can import is
limited to the number of empty slots.

Note:

You can filter the list of media by entering all or part of a
barcode in the Search text box. Use an asterisk (*) to search
with wildcards. You can also sort the list by clicking on
columns with bold headings. For example, selecting the
Location column heading sorts the list by location
coordinates.

The paths to open the appropriate screens are as follows:
•

From the Web client, select Operations > Media > Import.

•

From the operator panel, select Operations > Import Media.

For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Bulk Loading

9

Bulk loading is another way to load media into the library. If zero I/E
station slots are configured, you will always need to bulk load cartridges
into the library. If I/E station slots have been configured, you may want
to perform an initial bulk load when you first start using your library. The
library will perform an inventory after the bulk load is complete.
Before bulk loading, print out the Library Configuration report from the
Web client to see how the physical slots of the library are configured. The
report shows what slots are unavailable or configured as cleaning slots or
as I/E station slots. For information on accessing the report, see Viewing
the Library Configuration Report on page 268.
Caution:

Scalar i500 User’s Guide

Place cartridges in their appropriately configured slot
location; for example, cleaning cartridges should not be
placed in slots configured for storage.

246

Chapter 9 Running Your Library
Performing Media Operations

When I/E station slots have been configured as I/E slots, the I/E station
door is unlocked, and you can open the main access door to the library.
When all I/E station slots are configured as storage, the I/E station door
is always locked. You will not be able to open the main access door to
bulk load tape cartridges into the library without first unlocking the I/E
station door. If possible, bulk load the library before configuring the I/E
station slots as storage. Otherwise, unlock the I/E station door. For
information on locking and unlocking the I/E stations, see Locking and
Unlocking the I/E Stations on page 262. For information on configuring
I/E station slots, see Configuring I/E Station Slots on page 79.
To perform an initial bulk load, open the access door and manually insert
directly into storage slots as many cartridges as you plan to use. The
cartridges will not go in all the way if they are inserted incorrectly.
Note:

A small number of physical storage slots are inaccessible to the
robot and should not be used for any tape cartridges. These
slots appear as unavailable in the Library Configuration
report. For detailed information on these slots, see Unused
Slots on page 247.

Note:

When you open the main access door to load tape cartridges
into the library, the library will automatically generate a
Reliability, Availability, and Serviceability (RAS) ticket,
alerting you to the fact that the door was opened. For
information on resolving a RAS ticket, see About RAS Tickets
on page 481.

After the initial bulk load, you can use the Import Media screen to add
cartridges without interrupting library operations, as long as I/E station
slots have been configured. For more information, see Importing Media
on page 242.
Unused Slots

9

Each library configuration contains a limited number of slots that are not
accessible to the robot. The slot counts in this user’s guide do not include
these unusable slots.
In any library configuration, the picker cannot access the bottom slot in
each column in the lowest module in the stack due to the fact that there is

Scalar i500 User’s Guide

247

Chapter 9 Running Your Library
Performing Media Operations

not enough clearance at the bottom of the library for the robotic picker.
When bulk loading the library, do not insert storage or cleaning tapes into
the bottom row of the lowest module in the library configuration.

Moving Media

9

Once media has been imported into the library, you can use the Move
Media operation to move a single data cartridge between tape drives and
slots within a partition.
Note:

If your library has zero I/E station slots, you cannot move
cartridges to and from the I/E station. See Configuring I/E
Station Slots on page 79.

This topic focuses on using the library user interface, not the host
application, to move media. Using the library to move media may
necessitate performing an inventory of the library with the host
application. See your host application documentation for more
information.
Details on using the library to move media include:
• If the partition is online, it will be taken offline before the move is
performed and brought back online after the move is complete. You
will be asked to confirm that you want to take the partition offline.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

• You can select only the partitions to which you have been given
access.
• You can only move media within one partition at a time.
You need to provide the following information in the user interface to
move media:
• Partition — Lists the partitions that you have permission to access.
• Selected Media — The single cartridge that you want to move.
• Selected Destination — The location to which you want to move the
cartridge.

Scalar i500 User’s Guide

248

Chapter 9 Running Your Library
Performing Media Operations

Note:

You can filter the list of media by entering all or part of a
barcode in the Search text box. Use an asterisk (*) to search
with wildcards. You can also sort the list by clicking on
columns with bold headings. For example, selecting the
Location column heading sorts the list by location coordinates.

• The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Media > Move.
• From the operator panel, select Operations > Move Media.
For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Exporting Media

9

The Export Media operation enables you to export data cartridges from
storage slots to empty I/E station slots for removal from the library.
Note:

If your library has zero I/E station slots, you cannot import or
export media. See Configuring I/E Station Slots on page 79.

This topic focuses on using the library user interface, not the host
application, to export media. Using the library to export media may
necessitate performing an inventory of the library with the host
application. Also, if the host application has issued a prevent media
removal command, you will not be able to use the library user interface to
export media. See your host application documentation for more
information.
If you have AutoClean enabled, you can also export cleaning cartridges.
For information, see Exporting Cleaning Media on page 258.

Note:

Scalar i500 User’s Guide

Once the export operation has started, do not interfere with
the operation by opening and closing the I/E station door.

249

Chapter 9 Running Your Library
Performing Media Operations

Caution:

Some host applications may fail import/export operations
when the I/E station contains cartridges that are assigned
to another partition. Move cartridges from the I/E station
as soon as possible to avoid possible conflicts with the
other partitions.

Details on exporting cartridges include:
• If the partition is online, it will be taken offline before the export
operation is performed and brought back online after the operation is
complete. You will be asked to confirm that you want to take the
partition offline.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

• You can select only the partitions to which you have been given
access.
• You can only export cartridges if empty I/E station slots are
available.
• You must have access to the library’s I/E station and the operator
panel to import cleaning cartridges.
You need to provide the following information in the Export Media
screens to export media:
• Partition — The partition from which you want to export cartridges.
The screens include information about the partition mode (online or
offline) and the number of empty I/E station slots. The number of
cartridges you can export is limited to the number of empty slots.
• Media — The tape cartridges that you want to export.
Note:

Scalar i500 User’s Guide

You can filter the list of media by entering all or part of a
barcode in the Search text box. Use an asterisk (*) to search
with wildcards. You can also sort the list by clicking on
columns with bold headings. For example, selecting the
Location column heading sorts the list by location coordinates.

250

Chapter 9 Running Your Library
Performing Media Operations

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Media > Export.
• From the operator panel, select Operations > Export Media.
For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Loading Tape Drives

9

The Load Drive operation enables you to load a cartridge from a storage
slot into a tape drive. The storage slot and tape drive must be assigned to
the same partition.
This topic focuses on using the library user interface, not the host
application, to load tape drives. Using the library to load tape drives may
necessitate performing an inventory with the host application. See your
host application documentation for more information.
Details on loading tape drives include:
• If the partition is online, it will be taken offline before the load
operation is performed and brought back online after the operation is
complete. You will be asked to confirm that you want to take the
partition offline.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

• You can select only partitions to which you have been given access.
• Default tape drive locations are highlighted if the barcode field is
empty or the field is cleared.
You need to provide the following information in the Load Drive screens
to load tape cartridges into tape drives:
• Partition — The partition containing the cartridge you want to load
into a tape drive. The screens include information about the partition
mode (online or offline).
• Media — The tape cartridges that you want to move.

Scalar i500 User’s Guide

251

Chapter 9 Running Your Library
Performing Media Operations

Note:

You can filter the list of media by entering all or part of a
barcode in the Search text box. Use an asterisk (*) to search
with wildcards. You can also sort the list by clicking on
columns with bold headings. For example, selecting the
Location column heading sorts the list by location coordinates.

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Drive > Load.
• From the operator panel, select Operations > Load Drive.
For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Unloading Tape Drives 9

The Unload Drive operation allows you to unload a cartridge from a tape
drive to a storage slot. The storage slot and tape drive must be assigned to
the same partition.
This topic focuses on using the library user interface, not the host
application, to unload tape drives. Using the library to unload tape drives
may necessitate performing an inventory with the host application. See
your host application documentation for more information.
Details about unloading tape drives include:
• Only drives with media loaded appear on the screen.
• You can select only partitions to which you have been given access.
• If the affected partition is online, it will be taken offline before the
unload operation is performed, and brought back online after it is
complete.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

You need to provide the following information in the Unload Drive
screens to unload tape cartridges from tape drives:

Scalar i500 User’s Guide

252

Chapter 9 Running Your Library
Performing Media Operations

• Partition — The partition containing the tape drive that you want to
unload. The screens include information about the partition mode
(online or offline).
• Tape drive — The tape drive that contains the cartridge that you want
to unload.
Note:

You can sort the list of tape drives by clicking on columns with
bold headings. For example, selecting the Location column
heading sorts the list by location coordinates.

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Drive > Unload.
• From the operator panel, select Operations > Unload Drive.
For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Taking a Tape Drive
Online or Offline

9

There are two tape drive modes: online and offline.
• Online — Tape drive is available for use. This is the normal operating
mode for the tape drive.
• Offline — Tape drive is offline to the host application and is not
available for cartridge load and unload (move) operations initiated
by the host application, but it remains available for Web client or
operator panel initiated move commands.
Note:

If a cartridge is already in the tape drive when you take
the tape drive offline, then the host can still read and write
data on the tape.

Some operations require that the tape drive be offline. You can take a tape
drive offline rather than the entire library or partition so as to minimize
disruption of library operations.
This topic focuses on using the library user interface, not the host
application, to change the tape drive mode. Using the library to change
tape drive mode may affect the host application. See your host
application documentation for more information.

Scalar i500 User’s Guide

253

Chapter 9 Running Your Library
About Cleaning Tape Drives

Details on changing the tape drive mode include:
• The default tape drive mode is online.
• You can select only tape drives in partitions to which you have been
given access.
• The Online/Offline buttons toggle between modes.
• Once taken offline, tape drives remain offline until they are turned
online again, or the library is restarted. Restarting the library will
bring all offline tape drives back online.
Note:

If you change the mode of a control path tape drive to offline, a
caution dialog appears asking you to confirm the mode
change. For information on control path tape drives, see
Working With Control Paths on page 86.

The paths to open the appropriate screens are as follows:
•

From the Web client, select Operations > Drive > Change Mode.

•

From the operator panel, select Operations > Change Drive Mode.

For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

About Cleaning Tape Drives
Library tape drives require occasional cleaning. Cleaning cartridges are
used to remove accumulated residue from each tape drive’s read/write
head.
The library supports two methods for cleaning tape drives with cleaning
cartridges: AutoClean and Manual.
AutoClean — Configuring one or more dedicated cleaning slots

automatically enables AutoClean. Cleaning cartridges are stored in the
designated cleaning slots. When a tape drive needs cleaning, it notifies
the library, and the library automatically cleans the tape drive using a
cleaning cartridge loaded in a cleaning slot. Automatic cleaning is

Scalar i500 User’s Guide

254

Chapter 9 Running Your Library
About Cleaning Tape Drives

integrated into routine library operations. The host application requests
the library to move a tape cartridge. If the tape drive performing the
operation needs cleaning, the library will perform the move operation
and then automatically clean the tape drive with a cleaning cartridge
before informing the host application that the move operation is
complete.
When a cleaning cartridge has expired, a RAS ticket informs the user to
export the expired tape from the library. If more cleaning cartridges are
present, the next cleaning cartridge will be used for the next cleaning
request. If no more cleaning cartridges are available, a RAS ticket will
inform the user that the tape drive needs cleaning and that a cleaning
tape needs to be imported.
Only administrators can configure cleaning slots, thus enabling
AutoClean. When AutoClean is enabled, the library allows you to import
and export cleaning media through the I/E Station.
For information on configuring cleaning slots, see Configuring Cleaning
Slots on page 78. For information on importing and exporting cleaning
media, see Importing Cleaning Media on page 256 and Exporting
Cleaning Media on page 258.
Note:

Cleaning slots are not visible to the host application. To choose
host-based cleaning, do not configure any cleaning slots, and
configure your host application to manage cleaning tape
drives. Configuring cleaning slots on the library may affect the
host application. See your host application documentation for
information.

Manual Cleaning — When a tape drive needs cleaning, it notifies the
library. If the library’s AutoClean feature is not enabled (no cleaning slots
have been configured), the library generates a RAS ticket informing the
user that the tape drive needs cleaning. Administrators can clean tape
drives manually at any time, using commands on the operator panel or
Web client. For more information, see Manually Cleaning Tape Drives on
page 260.

Enabling AutoClean

Scalar i500 User’s Guide

9

To enable AutoClean, an administrator must configure at least one
cleaning slot in the library. For information on configuring cleaning slots,
see Configuring Cleaning Slots on page 78. For a description of
AutoClean, see About Cleaning Tape Drives on page 254.

255

Chapter 9 Running Your Library
About Cleaning Tape Drives

Viewing the Cleaning
Count

9

The cleaning count is the number of times a cleaning cartridge has been
used to clean a tape drive. Knowing this can help you decide when to
replace a cleaning cartridge. The cleaning count is now listed in two
locations:
•
•

Using Valid Cleaning
Media

9

Importing Cleaning Media9

Library Configuration Report (from the Web client, select Reports >

Library Configuration)

Export Cleaning Media screen (from the Web client, select Operations

> Cleaning Media > Export)

The preferred method of labeling a cleaning cartridge is to have CLN or
CLNU as the prefix on the label. Any cartridge detected with a CLN or
CLNU prefix will be considered a universal cleaning cartridge, regardless
of any media identification extension. Cartridges containing a media
identification of C1, C2, C3, C4, C5, and CU will be considered cleaning
cartridges and will be tracked and treated as if the media label contained
the prefix CLN or CLNU.

When AutoClean is enabled (at least one cleaning slot has been
configured), you can use the Import Cleaning Media operation to import
cleaning cartridges from the I/E station to designated cleaning slots. For
information on configuring cleaning slots, see Configuring Cleaning Slots
on page 78. For a description of AutoClean, see About Cleaning Tape
Drives on page 254.
When manual cartridge assignment is enabled (the default setting), you
cannot import cartridges via the operator panel until you have assigned
them to a specific partition or to the system partition. Cleaning cartridges
should always be assigned to the system partition. Assigning cleaning
cartridges to the system partition makes them available to all partitions in
the library. For more information about manual cartridge assignment, see
Importing Media on page 242 and Disabling/Enabling Manual Cartridge
Assignment on page 77.
You must have access to the library’s I/E station and the operator panel
to import cleaning cartridges.

Scalar i500 User’s Guide

256

Chapter 9 Running Your Library
About Cleaning Tape Drives

Caution:

Some host applications may fail import/export operations
when the I/E station contains cartridges that are assigned
to another partition. Move cartridges from the I/E station
as soon as possible to avoid possible conflicts with the
other partitions.

Note:

If your library has zero I/E station slots, you cannot import or
export cleaning media. See Configuring I/E Station Slots on
page 79.

Note:

Once the import operation has started, do not interfere with
the operation by opening and closing the I/E station door.

The process for importing cleaning cartridges includes the following
steps:
1 Go to the front of the library and insert the cartridges into the I/E
station.
Note:

Do not insert cartridges into the I/E station during the restart
process.

2 Close the I/E station door.
The Assign I/E screen appears on the operator panel if the Manual
Cartridge Assignment setting is enabled on the operator panel System
Settings screen (Tools > System Settings).
If the Assign I/E screen appears, do the following:
a On the Assign I/E screen, select System.
The System button turns red after it is selected. Selecting System
assigns the cartridge to the physical library and not to a specific
partition.
b

Select Apply.

3 Use the Import Cleaning Media screen on either the operator panel or
the Web client to import the cleaning cartridges into the library.
Follow the on-screen prompts, or see the library’s online Help for

Scalar i500 User’s Guide

257

Chapter 9 Running Your Library
About Cleaning Tape Drives

step-by-step procedures. To access the online Help system, click the
Help icon at the top right of the Web client or operator panel user
interface.
You need to provide the following information in the Import Cleaning

Media screens to import media:

• Media — the cleaning cartridges that you want to import.
The screen includes information about the number of empty cleaning
slots in the library. The number of cleaning cartridges you can import is
limited to the number of empty cleaning slots.
Note:

You can filter the list of media by entering all or part of a
barcode in the Search text box. Use an asterisk (*) to search
with wildcards. You can also sort the list by clicking on
columns with bold headings. For example, selecting the
Location column heading sorts the list by location coordinates.

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Cleaning Media > Import.
• From the operator panel, select Operations > Import Cleaning Media.

Exporting Cleaning Media9

When AutoClean is enabled, you can use the Export Cleaning Media
operation to export one or more cleaning cartridges from dedicated
cleaning slots to the I/E station for removal from the library. You may
need to export expired cleaning cartridges or free up cleaning slots for
data storage.
After exporting cleaning cartridges, you can reduce the number of
configured cleaning slots. The extra slots become available for use as
storage slots. For information on configuring cleaning slots, see
Configuring Cleaning Slots on page 78. For a description of AutoClean,
see About Cleaning Tape Drives on page 254.
Caution:

Scalar i500 User’s Guide

Some host applications may fail import/export operations
when the I/E station contains cartridges that are assigned
to another partition. Move cartridges from the I/E station
as soon as possible to avoid possible conflicts with the
other partitions.

258

Chapter 9 Running Your Library
About Cleaning Tape Drives

Note:

If your library has zero I/E station slots, you cannot import or
export cleaning media. See Configuring I/E Station Slots on
page 73.

Note:

Once the export operation has started, do not interfere with
the operation by opening and closing the I/E station door.

Details on exporting cleaning cartridges include:
• You must have access to the library’s I/E station and the operator
panel to export cleaning cartridges.
• You can only export cartridges if empty I/E station slots are
available.
You need to provide the following information in the Export Cleaning
Media screens to export cleaning media:
• Media — The tape cartridges that you want to export.
The screen includes information about the number of empty I/E station
slots in the library. The number of cleaning cartridges you can export is
limited to the number of empty I/E station slots. The screen also displays
the cleaning status (usable/expired) and cleaning count (the number of
times the cartridge was used to clean a tape drive) for each cleaning
cartridge in the library.
Note:

You can filter the list of media by entering all or part of a
barcode in the Search text box. Use an asterisk (*) to search
with wildcards. You can also sort the list by clicking on
columns with bold headings. For example, selecting the
Location column heading sorts the list by location coordinates.

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > Cleaning Media > Export.
• From the operator panel, select Operations > Export Cleaning Media.
For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Scalar i500 User’s Guide

259

Chapter 9 Running Your Library
About Cleaning Tape Drives

Manually Cleaning Tape
Drives
9

The Clean Drive screens allow administrators to manually clean tape
drives.
Note:

Be sure to unload the tape drive before attempting to clean it.
If the tape drive is loaded with a cartridge, it will not available
for this operation.

If you have at least one cleaning slot configured (see Configuring
Cleaning Slots on page 78), and you are using the Web client, you can
choose to use a cleaning tape from either a configured cleaning slot or the
topmost I/E station slot. If two or more cleaning slots are configured and
have cleaning tapes in them, the library chooses which cleaning tape to
use. If you have zero cleaning slots configured, or if you are using the
operator panel, you must use a cleaning tape in the topmost I/E station
slot. You are prompted to insert a cleaning cartridge in the appropriate
slot and select the tape drive you want to clean. The library then takes the
associated partition offline, moves the cleaning cartridge from the I/E
station slot to the designated tape drive, and cleans the tape drive. You
will be asked to confirm that you want to take the partition offline.
When the operation is complete, the library moves the cleaning cartridge
back to the I/E station slot and takes the partition back online.
Note:

If the operation does not complete successfully, the partition
remains offline until you turn it back online manually or
restart the library (see Taking a Partition Online or Offline on
page 76).

Note:

If your library has zero I/E station slots, you will not be able to
manually clean tape drives. See Configuring I/E Station Slots
on page 79.

For step-by-step procedures, see the library’s online Help. To access the
online Help system, click the Help icon at the top right of the Web client or
operator panel user interface.

Scalar i500 User’s Guide

260

Chapter 9 Running Your Library
About Tape Drive Operations

The paths to open the appropriate screens are as follows:
• From the Web client, select Tools > Drive Operations > Clean a tape
drive.
• From the operator panel, select Tools > Drive Mgmt > Clean drive.

About Tape Drive Operations
You can perform the following tape drive operations:
• Upgrade tape drive firmware using a firmware image file. For more
information, see Using an Image File to Upgrade Tape Drive
Firmware on page 282.
• Retrieve tape drive logs. Tape drive logs can be retrieved from any
tape drive installed in the library. For more information, see
Retrieving Tape Drive Logs on page 495.
• Retrieve tape drive sled logs. Tape drive sled logs can be retrieved
from any sled installed in the library. For more information, see
Retrieving Tape Drive Sled Logs on page 496.
• Clean tape drives. Tape drive can be cleaned manually at any time.
For more information, see About Cleaning Tape Drives on page 254.
• Upload/remove tape drive firmware for autoleveling. Available only
for FC tape drives connected to an FC I/O blade. For more
information, see Autoleveling Tape Drive Firmware on page 283.
• Reset tape drives. Resetting a tape drive power cycles the tape drive
while the tape drive remains in the drive sled in the library. For more
information, see Drive Reset on page 514.
• Force data path failover. For use with a Storage Networking license
and HP LTO-5 tape drives. See Forcing Data Path Failover on
page 158.

Scalar i500 User’s Guide

261

Chapter 9 Running Your Library
Locking and Unlocking the I/E Stations

Locking and Unlocking the I/E Stations
Each control module and expansion module has an I/E station door with
multiple open and close sensors. A secondary door located behind the
I/E station door acts as a redundant indicator as to whether the I/E
station is opened or closed. When you are finished accessing the I/E
station, make sure the station door is fully closed.
Administrators can use this operation to lock or unlock the doors for all
I/E stations that are configured as I/E station slots. If all I/E station slots
are configured as storage, this operation unlocks the control module I/E
station only.
Note:

Some host applications use a command to lock and unlock I/E
station doors. This command usually cannot be overridden by
the library. Use the host application to lock or unlock I/E
station doors if this occurs. Using the library lock/unlock
operation may affect the host application. See your host
application documentation for information.

There are three reasons the I/E station door locks:
• The library imports or exports a cartridge from the I/E station door.
While the library is attempting to import or export a tape from a
given I/E station slot, only the associated I/E station door is locked
in the closed position. All other I/E station doors remain accessible.
On a “get” from an I/E station slot, the associated I/E station door
remains locked until the media has been successfully moved to its
destination. This allows the media to be returned to the I/E station
slot in the event of a put error.
• A user has requested that the I/E station door be locked.
• If the I/E station slots are configured as storage slots, the door is
always locked. When all I/E station slots are configured as storage
slots, you can use the Locking and Unlocking I/E station operation to
unlock the I/E station in the control module. When the I/E station is
unlocked, you can open the main access door on the control module.
This, in turn, unlocks all remaining I/E stations in the library,
allowing you to access all remaining access doors in the library.

Scalar i500 User’s Guide

262

Chapter 9 Running Your Library
Controlling FC I/O Blade Power

The paths to open the appropriate screens are as follows:
• From the Web client, select Operations > I/E Station.
• From the operator panel, select Operations > Lock/Unlock I/E Station.

Controlling FC I/O Blade Power
Administrators can turn on, turn off, or power cycle individual FC I/O
blades in the library. Turning off or power cycling the FC I/O blade will
cause a temporary loss of communication with connected hosts. The
screen will display a warning message about the communication loss and
ask you to confirm that you want to proceed.
The Setup - Blade Control screen allows you to perform the following
operations on the selected FC I/O blades:
On the Web client:
• Click On to turn on the FC I/O blade.
• Click Off to turn off the FC I/O blade.
• Click Cycle to power cycle the FC I/O blade. It takes approximately 3
minutes to power cycle a blade.
On the operator panel, select the option you want:
• Power Cycle Blade
• Power On Blade
• Power Off Blade
Note:

Scalar i500 User’s Guide

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

263

Chapter 9 Running Your Library
Controlling FC I/O Blade Power

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > I/O Blades > Blade Control.
• From the operator panel, select Setup > I/O Blades > Blade Control.

Scalar i500 User’s Guide

264

Chapter 10

10

Getting Information – Logs and
Reports

This chapter describes how to find information about your library.
From the operator panel, you can find system information in the About
Scalar i500 screen (Tools > About Library). From the Web client, you can
find information in the Reports and Tools menus.
Note:

Users without administrator privileges can view only certain
reports. See User Privileges on page 50 for information about
user privileges.

This chapter covers:
• Viewing Information About the Scalar i500
• Viewing the System Information Report
• Viewing the Library Configuration Report
• Viewing the Network Settings Report
• Viewing Logged-in Users
• Viewing the All Slots Report
• Viewing, Saving, and E-mailing Library Logs
• Viewing FC I/O Blade Information
• Viewing FC I/O Blade Port Information

Scalar i500 User’s Guide

265

Chapter 10 Getting Information – Logs and Reports
Viewing Information About the Scalar i500

Viewing Information About the Scalar i500
The About screen gives you a quick glance at your library settings.
From the Web client, you can view the About Scalar i500report, which
provides the following information about the library:
• Serial Number
• Firmware Version Number
From the operator panel, the About screen provides the following
information about the library:
• Library name
• State
• Serial number
• System firmware version number
• Date and time of last firmware update
• Current date and time
From the operator panel About screen, you can also navigate to other
screens for detailed information about:
• the network (IP addresses)
• tape drives
• partitions
The paths to open the appropriate screens are as follows:
• From the Web client, select Reports > About > Scalar i500.
• From the operator panel, select Tools > About Library.

Scalar i500 User’s Guide

266

Chapter 10 Getting Information – Logs and Reports
Viewing the System Information Report

Viewing the System Information Report
The System Information Report contains information on the following
library settings:
• Date and time — current date, time, and time zone settings
• Physical library — host name, Internet Protocol (IP) address(es), serial
number, firmware version, board support package (BSP) level, the
date the BSP was last updated, and robot firmware version.
• Encryption (this section displays only if encryption key management
is licensed and configured on the library) — key server type;
encryption software version; SSL connection (enabled/disabled);
primary host (primary key server IP address or host name), primary
key server port number; primary key server serial number; secondary
host (secondary key server IP address or host name); secondary key
server port number; secondary key server serial number.
• Library Partitions— name, serial number, control path, mode,
encryption method, encryption system type, number of slots, number
of media, number of tape drives, and whether FIPS is configured for
each partition.
• Tape drives — location coordinates, vendor name, model, type,
physical serial number (P-SN), logical serial number (L-SN),
firmware level, sled boot version, sled application version,
encryption method, and whether the tape drive is connected to an
I/O blade.
• FC I/O blades — if the library contains FC I/O blades, this table lists
the location coordinates, World Wide Node Name (WWNN),
firmware level, and ready status.
• EE blades — if the library contains Ethernet Expansion blades, this
table lists the location coordinates and status.
The path to open the report from the Web client is Reports > System

Information.

Scalar i500 User’s Guide

267

Chapter 10 Getting Information – Logs and Reports
Viewing the Library Configuration Report

Viewing the Library Configuration Report
The Library Configuration Report is a dynamic representation of the
physical locations of various library resources, including tape drives,
slots, partitions, and modules.
Each partition’s slots are displayed in a unique color, indicated in the
legend. I/E station slots, cleaning slots, and unavailable slots are also
displayed in unique colors. A black triangle in the upper left corner of a
slot indicates media is present in the slot. A red triangle indicates media
is present but the media barcode label is unreadable. A “c” in a tape drive
indicates the drive is the control path for the partition.
By default, the Library Configuration Report displays the coordinates for
all licensed slots that are assigned to a partition. To view all library slot
coordinates, click Show ALL coordinates. To display the barcodes for all
imported cartridges, click Show Barcodes.
Figure 36 shows an example of the Library Configuration Report.

Scalar i500 User’s Guide

268

Chapter 10 Getting Information – Logs and Reports
Viewing the Library Configuration Report

Figure 36 Library Configuration
Report

Use the report to view detailed information on the following resources.
Click on the item you want to view and the information appears in a box
to the right of the library diagram.
• Tape drives — Depending on the interface type, the information
provided may not include all of the following: interface type, tape
drive type, ready state, mode (online/offline), assigned partition
name, location coordinates, media barcode (“No_Label” means
unreadable barcode), media type, element address, vendor, model,
Scalar i500 User’s Guide

269

Chapter 10 Getting Information – Logs and Reports
Viewing the Library Configuration Report

physical SN, logical SN, World Wide Node Name (WWNN), World
Wide Port Name (WWPN), loop ID, topology request, speed request,
actual topology, actual speed, maximum speed, active port (if the
drive has more than one FC port), SNW licenses (displays which
Storage Networking features the tape drive is using, if any; see
Chapter 6, Storage Networking), SCSI ID, SAS address, tape drive
firmware level, control path status, and encryption method of each
tape drive.

Note:

The library configuration report lists the native device
identifier as reported by the tape drive. HP tape drives
always report SCSI as the native device identifier, even if
they are Fibre Channel or SAS. For example, if you have
HP L TO-4 Fibre Channel or SAS drives, they will be listed
in the report as HP LTO-4 SCSI drives.

• Slots —Type, assigned partition name (storage and import/export
[I/E] station slots only), location coordinates, barcode (storage and
I/E station slots only), media type, element address, encryption
method, get count, get retries, put count, and put retries. If the slot is
a cleaning slot, the cleaning status (usable/expired) and cleaning
count (the number of times the cartridge was used to clean a tape
drive) are also displayed. For more details about slot data, see
Viewing the All Slots Report on page 272.
• Partitions— Name, online status, emulation type, barcode policy,
number of total tape drives in the partition, number of active tape
drives partition, total media, mounted media, total slots, full slots,
total I/E stations, full I/E stations, and encryption method of each
partition.
• Modules (Chassis) — Manufacturer, model type, and serial number of
each module.
You can print the report by clicking on the printer icon in the report
window.
The path to open the report from the Web client is Reports > Library
Configuration.

Scalar i500 User’s Guide

270

Chapter 10 Getting Information – Logs and Reports
Viewing the Network Settings Report

Viewing the Network Settings Report
The Network Setings Report provides information on the following
library network settings:
• Network — host name, primary DNS, alternate DNS.
• IPv4 Settings — Dynamic Host Configuration Protocol (DHCP)
enabled/disabled, IP address, gateway address, and net mask.
• IPv6 Settings (if IPv6 is enabled) — DHCP enabled/disabled,
Stateless enabled/disabled, Static enabled/disabled, network prefix,
gateway, and all IPv6 addresses.
• SSL — SSL, port, and cipher of the library.
• SMI-S — access and state enabled/disabled settings of the library.
•

•

Access: Indicates whether the SMI-S port for SMI-S traffic to the

library (port 5988) is enabled or disabled. You can change the
setting via the operator panel, Tools > Security menu. The default
setting is enabled.
State: Indicates whether allowing SMI-S to run on the library is
enabled or disabled. You can change this setting on the operator
panel, Tools > System Settings. The default is disabled.

• SNMP — access enabled/disabled, V1 enabled/disabled, V2
enabled/disabled, V3 enabled/disabled, algorithm, encryption
enabled/disabled, and port.
• SNMP-Traps — IP addresses and ports.
The path to open the report from the Web client is Reports > Network
Settings.

Scalar i500 User’s Guide

271

Chapter 10 Getting Information – Logs and Reports
Viewing Logged-in Users

Viewing Logged-in Users
The Logged-in User’s Report report contains information about the users
that are currently logged into the library. The report contains the
following information:
• User name — Name of logged-in user.
• Role name — Privilege level of logged-in user (for example, Admin for
administrator, User for non-administrator, non-service user).
• Login date and time — Date and time the user logged into the library.
• Last activity date and time — Date and time the user last logged into
the library.
• Login location — IP address or host name of the system being used to
access the system.
• Management interface — User interface being used to access the
system (Web client or operator panel).
The path to open the report from the Web client is Reports > Logged in

Users.

Viewing the All Slots Report
The All Slots Report contains information on all slots that are currently
assigned to a partition and all I/E slots. A maximum of 20 responses
displays per page. You can scroll between the pages using the page
arrows at the bottom left of the screen. The report contains the following
information about each slot:
• Slot type — Drive, I/E station, cleaning, or storage slot.
• Barcode — Barcode number of the cartridge installed in the slot (no
barcode number means the slot is empty).
• Partition — The partition that owns the slot.

Scalar i500 User’s Guide

272

Chapter 10 Getting Information – Logs and Reports
Viewing, Saving, and E-mailing Library Logs

• Location — Location coordinates of the slot. (For a description of
location coordinates, see Understanding the Location Coordinates on
page 32.)
• Element Address — Element address of the slot.
• Encryption — The encryption state of the media in the slot. In order
for the library to know the encryption state, the tape must have been
placed into an encryption-capable tape drive in the library. The
encryption-capable tape drive reads and records the encryption state
of the tape, and the encryption state displays as “Encrypted” or “Not
Encrypted.” If the tape was not placed into an encryption-capable
tape drive in the library, or if the slot is empty, the encryption state
displays as “Unknown.”
• Get Count — The number of times the picker successfully removed a

tape from the slot.

• Get Retries — The number of times the picker had to perform a

recovery operation to remove a tape from the slot.

• Put Count — The number of times the picker successfully placed a

tape into the slot.

• Put Retries — The number of times the picker had to perform a

recovery operation to place a tape into the slot.
Note:

“Get” and “put” counts and retries are counted from the
beginning of library use to the present. If the LCB compact
flash card is replaced, the count starts over at zero.

The path to open the report from the Web client is Reports > All Slots.

Viewing, Saving, and E-mailing Library Logs
The library collects specific information in log files that you can view
onscreen, save to your computer, or e-mail to a recipient. The following
library logs are available:
• Installation Verification Test Summary Log — This log is saved each
time you run the Installation Verification Test (IVT). The log saves
only the information from the most recently run test. If you run the
Scalar i500 User’s Guide

273

Chapter 10 Getting Information – Logs and Reports
Viewing, Saving, and E-mailing Library Logs

test again, the new information overwrites the previous information.
This option presents the summary log. For more information, see
Using the Installation Verification Test on page 509.
• Installation Verification Test Detailed Log— This log is saved each time
you run the Installation Verification Test (IVT). The log saves only the
information from the most recently run test. If you run the test again,
the new information overwrites the previous information. This
option presents the detailed log. For more information, see Using the
Installation Verification Test on page 509.
• Command History Log — Available only if you are using FC I/O
blades. When you select this report, you choose the FC I/O blade and
device for which you want to run the report. The Blade menu lists all
FC I/O blades installed in the library (if more than one are installed).
The Devices menu lists the devices associated with the selected FC
I/O blade. The report shows all commands from the selected device
to the selected blade. When the log file reaches its maximum size, the
oldest information is replaced as new information is added.
• Cleaning Log — Shows all cleanings that have been performed in the
library since firmware version 520G was installed. When the log
reaches its maximum size, the oldest information is replaced as new
information is added. The comma-separated values (csv) file
provides the following information:
Date Time (date and time); Barcode (barcode of the cleaning
cartridge); Tape (location coordinates of the cleaning cartridge);
Drive (location coordinates of the tape drive that was cleaned); Status
(pass/fail); Return Code (service use only), Cleaning Type (Manual,
Auto, MoveMedium), Expired (“Invalid” if the tape is expired or a
data tape was improperly used to clean; “-“ if not applicable); Usage
Count (“N/A” if the cleaning did not complete); Reserved.
• Slot Position Log — Shows current information for all slots in the
library. The comma-separated values (csv) file provides the following
information for each slot:
Date and Time, Slot Type (Picker, Drive, Storage, or IE), Object
Present? (Y, N), Location Coordinates, X Position, Y Position, Angle
Position, X Calibration Offset, Y Calibration Offset.
• RAS Tickets Log — Records all RAS tickets for the library. When the
log file reaches its maximum size, the oldest information is replaced
as new information is added.

Scalar i500 User’s Guide

274

Chapter 10 Getting Information – Logs and Reports
Viewing FC I/O Blade Information

• Media Security Log — Lists media that have been completely
removed from the library. This log is only available if you have an
Advanced Reporting license installed on the library (see Obtaining
and Installing a License Key on page 88), and you have enabled the
library to collect data for the log file. For more information about this
log and how to enable the library to collect data for the log, see
Configuring and Viewing the Media Security Log on page 143.
• Media Usage Log — Lists information regarding data written and
read on the medium and lists statistics pertaining to soft and hard
read and write errors. This log is only available if you have an
Advanced Reporting license installed on the library (see Obtaining
and Installing a License Key on page 88). For more information about
the information displayed in this log, see Viewing the Media Usage
Log on page 144.
• SKM Encryption Key Import Warning Log — Lists keys that failed the
most recent data key import operation. This log is only available if
you are running Scalar Key Manager (SKM). For detailed information
about this log, see Using the SKM Encryption Key Import Warning
Log on page 197.
The path to open the report from the Web client is Reports > Log Viewer.

Viewing FC I/O Blade Information
Administrators can view information about all the FC I/O blades
installed in the library. The Tools - Blade Information screen lists the
following FC I/O blade information:
• Location—Library location coordinates of the blade:
[module,blade#], where blade# is 1 for the top blade in the module
and 2 for the bottom blade in the module.
• Firmware Version—Firmware version of the blade (part of the library
firmware).
• Serial Number— Serial number of the blade.
• WWNN—World Wide Node Name of the blade.

Scalar i500 User’s Guide

275

Chapter 10 Getting Information – Logs and Reports
Viewing FC I/O Blade Port Information

• CCL— Command control LUN.
• Status/State—The status of the blade can be: Ready, Not Ready, Auto
Level Failed, Auto Leveling Booting, and Unknown.
The paths to open the appropriate screens are as follows:
• From the Web client, select Tools > I/O Blade Info.
• From the operator panel, select Tools > Blade Info.

Viewing FC I/O Blade Port Information
Administrators can view information about all the FC I/O blades
installed in the library. The Tools - Blade Port Information screen lists the
following port information for each FC I/O blade:
• Port number — The port number: 1–6.
• WWPN — World Wide Port Name of the port.
• Status — The status of the blade: Config wait, Loop init, Login,
Ready, Lost Sync, Error, Re-Init, Non part, and Failed.
• Actual Speed — Negotiated speed of the port: 1 Gb/s, 2 Gb/s, or
4 Gb/s. If the port is not in a ready state, “N/A” displays.
• Actual Loop ID — Negotiated loop ID of the port: 0–125. On the Web
client, if the port connection type is Point to Point, or if the port is not
in a ready state, “N/A” displays. On the operator panel, if the port is
not in a ready state, “N/A” displays.
• Requested Speed — Requested speed of the port: Auto, 1 Gb/s,
2 Gb/s, 4 Gb/s, or 8 Gb/s (Web client only).
• Requested Loop ID — Requested loop ID of the port: Auto or 0–125
(Web client only).
• Framesize — Framesize setting of the port: 528, 1024, or 2048.
• Mode — Mode of the port: Public or Private.
• Role — Role of the port: Target (ports 1–2) or Initiator (ports 3–6).
• Connection — Connection type of the port: Loop, Point to Point, or
Loop Preferred.
Scalar i500 User’s Guide

276

Chapter 10 Getting Information – Logs and Reports
Viewing FC I/O Blade Port Information

For information about configuring FC I/O blade ports, see Configuring
FC I/O Blade Ports on page 110.
The paths to open the appropriate screens are as follows:
• From the Web client, select Tools > I/O Blade Port Info.
• From the operator panel, select Tools > Blade Info > Port Info.

Scalar i500 User’s Guide

277

Chapter 11

11

Updating Library and Tape
Drive Firmware

There are two types of firmware that can be upgraded on the library:
library firmware (including drive sled firmware) and tape drive
firmware. There may be times when you will need to upgrade your
library and tape drive firmware as directed by Quantum Support.
You can find release notes, upgrade instructions, and a listing of the latest
version of firmware on the Quantum Web site at:
http://www.quantum.com/ServiceandSupport/SoftwareandDocument
ationDownloads/SI500/Index.aspx.
You need to contact Quantum Support directly to receive the firmware
itself. Before loading firmware, check the release notes to make sure that
it is compatible with your library and tape drives.
This chapter covers:
• Upgrading Library Firmware
• Upgrading Tape Drive Firmware
• Autoleveling Tape Drive Firmware

Scalar i500 User’s Guide

278

Chapter 11 Updating Library and Tape Drive Firmware
Upgrading Library Firmware

Upgrading Library Firmware
The library firmware upgrade operation allows you to upgrade library
firmware using the Web client. Upgrading library firmware can take up
to an hour for large configurations. Contact Quantum Support for a copy
of the latest firmware. Download the file to your computer hard drive.
Library firmware comes bundled with tape drive firmware, firmware
upgrade instructions, and release notes. Verify with the release notes or
Quantum Support that you are updating the library with the correct
version of firmware. For technical support see Getting More Information
or Help on page 8.
Library firmware version 200G.GSxxx and 210G.GSxxx (SP1) support
library configurations of up to 14U. Library firmware 300G.GSxxx (I1)
supports library configurations up to 23U. Library firmware versions
320G.GSxxx (SP3) and higher support library configurations up to 41U.
Make sure you are running the appropriate firmware version to support
the size of your library. It is recommended that you use the most current
version of firmware regardless of library size.
• To determine the latest version of library firmware, refer to the
release notes or check the Quantum Web site at:
http://www.quantum.com/ServiceandSupport/SoftwareandDocu
mentationDownloads/SI500/Index.aspx.
• To find out the latest version of tape drive firmware, refer to the
release notes.
Release notes and instructions for upgrading library and tape drive
firmware can be found here:
http://www.quantum.com/ServiceandSupport/SoftwareandDocument
ationDownloads/SI500/Index.aspx.
It is recommended that you resolve and close all open RAS tickets before
upgrading library firmware. If Auto-Ticket Closure is enabled, all open
RAS tickets will be closed during the reboot which occurs after firmware
is upgraded (see Closing RAS Tickets Automatically on page 485).
Saving the current library configuration before you upgrade library
firmware is recommended in case the upgrade fails. After you have
upgraded the firmware, save the library configuration again. For more
information, see Saving and Restoring the Library Configuration on
page 488.

Scalar i500 User’s Guide

279

Chapter 11 Updating Library and Tape Drive Firmware
Upgrading Library Firmware

It is also a good idea to capture a library snapshot information before
making any significant change to your system such as upgrading library
firmware. Technical support personnel can, if necessary, use the snapshot
file to troubleshoot the library. For more information, see Capturing
Snapshots of Library Information on page 485.
Caution:

If you are currently running library firmware version
320G.GS004 or 400G.GS006, you must first install and run
the Library Service Utility before upgrading firmware. If
you do not first run the Library Service Utility, then the
firmware upgrade may not complete successfully. The
Library Service Utility and installation instructions are
located in the “.zip” file that contains the firmware
download files.
If you are currently running library firmware prior to
version 320G.GS004, do not upgrade to version
320G.GS004 or 400G.GS006, but instead upgrade to the
latest version. You will not need to run the Library Service
Utility.

Scalar i500 User’s Guide

Note:

If you downgrade from one major firmware version to an
earlier major version, library configuration settings will be
reset to the factory defaults. You can restore the other
configurable items using a configuration file that was saved
when the earlier version of library firmware was installed on
the library, or you can reconfigure your library’s settings. For
more information, see Saving and Restoring the Library
Configuration on page 488.

Note:

If you are running firmware version 400G or higher and want
to downgrade, the following restrictions apply:
• If your library is Quantum branded, you can downgrade to
version 400G or higher (there is no lower version of
Quantum-branded firmware).
• If your library is ADIC branded and has FC I/O blades
installed, you can downgrade to version 400G or higher.
Firmware versions 320G and lower do not support FC I/O
blades. If your library does not have FC I/O blades, you can
downgrade to a lower version of firmware.

280

Chapter 11 Updating Library and Tape Drive Firmware
Upgrading Tape Drive Firmware

Note:

If your library is running firmware version 600G or later, you
can only downgrade library firmware to version 410G or later.
If you need to downgrade to a version earlier than 410G,
contact Quantum Support for assistance.

Note:

If you purchased your library after October 15, 2008, you
cannot downgrade library firmware to below version 520G.

Note:

This operation should not be performed concurrently by
multiple administrators. You can access the screen, but you
cannot apply changes while another administrator is
performing the same operation.

Note:

The library automatically restarts after the firmware upgrade
is complete. Before logging into the library, clear the Web
browser cache. See your Web browser’s documentation for
instructions on how to clear the cache.

You can find instructions on updating library firmware on the Quantum
Website. You can also find step-by-step instructions in your library’s
online Help. To access the online Help system, click the Help icon at the
top right of the Web client or operator panel user interface.
You cannot upgrade library firmware from the operator panel. The path
to open the appropriate screen is as follows:
• From the Web client, select Tools > Update Library Firmware.

Upgrading Tape Drive Firmware
You can use the Web client to upgrade one or more tape drives in your
library with an image file obtained from Quantum Support.

Scalar i500 User’s Guide

281

Chapter 11 Updating Library and Tape Drive Firmware
Upgrading Tape Drive Firmware

Using an Image File to
Upgrade Tape Drive
Firmware
11

The Web client allows you to upgrade tape drive firmware using a
firmware image file. The firmware upgrade can take up to 40 minutes
(less if the upgrade is performed using FC I/O blades).
Tape drive firmware is available from Quantum Support. Verify with the
release notes or Quantum Technical Support that you are updating the
tape drives with the correct version of firmware.
Details on using an image file to upgrade tape drive firmware include:
• The library allows you to upgrade firmware on multiple tape drives
at one time. Upgrade firmware on all tape drives of the same
interface type at the same time to make sure that all drives are at the
same firmware level. Having different levels of drive firmware in the
library is not recommended.
• Each tape drive interface type requires unique firmware. The image
file must contain the appropriate SCSI, FC, or Serial Attached SCSI
(SAS) firmware image for the corresponding SCSI, FC or SAS drive
type.
• The tape drive and associated partition are automatically taken
offline during the operation and brought back online when the
operation completes. You will be asked to confirm that you want to
take the tape drive and partition offline.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

Instructions for upgrading tape drive firmware can be found in the online
help and at:
http://www.quantum.com/ServiceandSupport/SoftwareandDocument
ationDownloads/SI500/Index.aspx.. You can also find step-by-step
instructions in your library’s online Help. To access the online Help
system, click the Help icon at the top right of the Web client or operator
panel user interface.
Caution:

Scalar i500 User’s Guide

Since tape drives restart after a firmware upgrade, make
sure that cartridges are not loaded in the applicable tape
drives before upgrading firmware.

282

Chapter 11 Updating Library and Tape Drive Firmware
Autoleveling Tape Drive Firmware

Caution:

Note:

Do not turn off power to the library during the upgrade
process. Turning off power to the library during the
upgrade can cause problems with the library.

This operation should not be performed concurrently by
multiple administrators. You can access the appropriate
screens, but you cannot apply changes while another
administrator is performing the same operation.

You cannot upgrade tape drive firmware with an image file from the
operator panel. The path to the appropriate screen is as follows:
• From the Web client, select Tools > Drive Operations.

Downgrading IBM LTO-4
Tape Drive Firmware 11

IBM LTO-4 drive brick firmware PGA3 (82FB) and newer contain special
security restrictions that prevent downgrading this firmware to previous
versions that are not FIPS-compliant [for example, PGA1 (77BE)].
If you need to downgrade LTO-4 tape drive firmware from level 82FB or
higher to level 77BE or lower, contact Quantum Technical Support for
instructions and assistance.

Autoleveling Tape Drive Firmware
The autoleveling feature enables you to automatically upgrade firmware
on all FC tape drives that are connected to the FC I/O blades or Ethernet
Expansion blades. This allows you to keep all FC tape drives of the same
type (for example, LTO-5) at the same firmware level. Tape drive
firmware is checked whenever a tape drive is reset, such as when the
library is power cycled or restarted, or whenever a tape drive is added or
replaced. If the firmware does not match, the tape drive firmware is
autoleveled.
FC tape drives must be connected to an FC I/O blade or an Ethernet
Expansion blade to participate in autoleveling operations. The library
does not support autoleveling FC tape drives connected directly to an FC

Scalar i500 User’s Guide

283

Chapter 11 Updating Library and Tape Drive Firmware
Autoleveling Tape Drive Firmware

host or switch. In addition, the library does not support autoleveling SCSI
or SAS tape drives.
To enable autoleveling, you must upload a firmware image file to the
library. If you have multiple versions of FC tape drives installed in your
library (for example, LTO-4 and LTO-5), you must upload a unique
firmware image file for each version. You can also delete a firmware
image file when you no longer want to autolevel tape drive firmware.

Uploading Tape Drive
Firmware Used in
Autoleveling
11

Before uploading tape drive firmware, verify with published release
notes or Quantum Support that you are uploading the correct version of
firmware. For contact information, see Getting More Information or Help
on page 8.
You must have access to a tape drive firmware image file to enable
autoleveling. Tape drive firmware is available from Quantum Support.
It is not necessary to delete an old version of firmware before uploading a
new version. The new version of firmware overwrites the old version.
You can find step-by-step instructions in your library’s online Help. To
access the online Help system, click the Help icon at the top right of the
Web client or operator panel user interface.
You cannot upload tape drive firmware from the operator panel. The
path to the appropriate screen is as follows:
• From the Web client, select Tools > Drive Operations > Upload/remove
tape drive firmware for autoleveling.

Deleting Tape Drive
Firmware Used in
Autoleveling

11

The library allows you to delete a firmware image file if you no longer
want to autolevel tape drive firmware. In addition, you might want to
delete a firmware image file if your library no longer contains a specific
version of tape drives. For example, if you replace all LTO-3 tape drives
with LTO-4 tape drives, you no longer need the LTO-3 firmware.
You can find step-by-step instructions in your library’s online Help. To
access the online Help system, click the Help icon at the top right of the
Web client or operator panel user interface.

Scalar i500 User’s Guide

284

Chapter 11 Updating Library and Tape Drive Firmware
Autoleveling Tape Drive Firmware

You cannot upload tape drive firmware from the operator panel. The
path to the appropriate screen is as follows:
• From the Web client, select Tools > Drive Operations > Upload/remove
tape drive firmware for autoleveling.

Scalar i500 User’s Guide

285

Chapter 12

12

Installing, Removing, and
Replacing

This chapter describes how to add, remove, and replace hardware within
your library. Adding, removing, or replacing library components may
require you to power off the entire library. There are a few components,
however, that you can service without powering off the library, such as
replacing tape drives. Instead, you may only need to take a specific
partition offline, or you may not need to impact the status of the library at
all.
Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, allow 60 cm (24
inches) in the front and back of the library.

Warning:

Scalar i500 User’s Guide

Under no circumstances should a rack be moved while
loaded with one or more modules.

286

Chapter 12 Installing, Removing, and Replacing

Warning:

Without tape drives, tape cartridges, or power supplies, a
control module weighs approximately 60 lbs (27.2 kg). An
expansion module, without tape drives, tape cartridges, or
power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.

This chapter covers:
• Taking the Library Online/Offline
• Cabling the Library
•

Specific Instructions for LTO-5 and LTO-6 Tape Drives

•

Cabling Libraries With SCSI Tape Drives

•

Cabling Libraries With SAS Tape Drives

•

Cabling Libraries With Fibre Channel Tape Drives Connected
Directly to a Host or Switch

•

Cabling Libraries With Fibre Channel Tape Drives Connected to
Fibre Channel I/O Blades

•

Recommended Library Cabling for FC I/O Blades

•

Managing Ethernet Cables

• Cable Management Guidelines
• Installing a Stand-Alone 5U Control Module
• Installing a New Multi-Module Library Configuration
• Adding Expansion Modules to an Existing Library
• Preparing to Remove or Replace a Module
• Permanently Removing Expansion Modules From an Existing
Library
• Replacing the Control Module
• Replacing an Expansion Module
• Removing and Replacing the Library Control Blade and LCB
Compact Flash Card
• Adding, Removing, and Replacing Power Supplies
• Installing the Library in a Rack
Scalar i500 User’s Guide

287

Chapter 12 Installing, Removing, and Replacing
Taking the Library Online/Offline

• Adding, Removing, and Replacing Tape Drives
• Adding, Removing, and Replacing FC I/O Blades
• Adding, Removing, and Replacing the FC I/O Fan Blade
• Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade
•

Cabling a 5U Library for Ethernet Connectivity

•

Installing the Ethernet Expansion Blade

•

Permanently Removing or Relocating an Ethernet Expansion
Blade

•

Replacing an Ethernet Expansion Blade in the Same Location

•

Viewing Ethernet Connectivity

• Preparing the Library for Moving or Shipping

Taking the Library Online/Offline
An online library allows a host application to fully control library
operations. Taking a library offline switches library control to the user
interfaces and limits host application command requests.

Taking a Library Online12

To take an entire library online, take all of its partitions online.
1 Using the library’s operator panel, select Operations > Change
Partition Mode; or, using the Web client, select Operations > Partitions
> Change Mode.
2 For each partition that you want to take online, click Online.
3 Click Apply.

Scalar i500 User’s Guide

288

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Taking a Library
Offline

12

To take an entire library offline, take all of its partitions offline.
1 Using the library’s operator panel, select Operations > Change
Partition Mode; or, using the Web client, select Operations > Partitions
> Change Mode.
2 For each partition that you want to take offline, click Offline.
3 Click Apply.

Cabling the Library
Use the following cabling procedure appropriate for your drive type.
• Specific Instructions for LTO-5 and LTO-6 Tape Drives on page 289
• Cabling Libraries With SCSI Tape Drives on page 293
• Cabling Libraries With SAS Tape Drives on page 298
• Cabling Libraries With Fibre Channel Tape Drives Connected
Directly to a Host or Switch on page 303
• Cabling Libraries With Fibre Channel Tape Drives Connected to
Fibre Channel I/O Blades on page 308
• Recommended Library Cabling for FC I/O Blades on page 313
• Managing Ethernet Cables on page 320

Specific Instructions for
LTO-5 and LTO-6 Tape
Drives
12

Scalar i500 User’s Guide

The library handles the Ethernet and Fibre Channel data ports on LTO-5
and LTO-6 tape drives differently depending on the tape drive. See
Figure 37, Figure 38, and Figure 39 for details.

289

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Scalar i500 User’s Guide

Caution:

LTO-5 Fibre Channel tape drives can be configured for
speeds of up to 8 GB per second and support autonegotiation to 8 Gb/s, 4 Gb/s, and 2 Gb/s. If they are
configured for 8 Gb/s, you should connect them directly
to a host or switch and not to an FC I/O blade, because the
FC I/O blade only allows speeds up to 4 Gb/s. If you
connect an LTO-5 Fibre Channel tape drive to an FC I/O
blade, the speed will autonegotiate to 4 Gb/s (see Setting
Tape Drive Parameters on page 83). Speeds less than 2
Gb/s are not supported.

Caution:

If you enable data path failover, control path failover, or
host access control, do not connect the tape drive to an FC
I/O blade.

Caution:

Do not connect a tape drive to both an FC I/O blade and
an Ethernet Expansion blade.

290

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 37 HP LTO-5 Dual Port
Fibre Channel Tape Drive

1 Ethernet port — Use for Ethernet
connectivity in conjunction with
FIPS.
2 Fibre Channel port 1 — Default
data port. If you are only using one
port, use this port.
3 Fibre Channel port 2 — Default
failover port (for use with data
path failover).

Scalar i500 User’s Guide

291

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 38 HP LTO-5 Single
Port SAS Tape Drive

1

Ethernet port - do not use

2

SAS port - use this port

1

Ethernet port - do not use

2

Fibre Channel port - use this port

Figure 39 IBM LTO-5 Single
Port Fibre Channel Tape Drive

Scalar i500 User’s Guide

292

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Cabling Libraries With
SCSI Tape Drives
12

Use this procedure, along with Figure 40 and Figure 41, if you are
installing a library that includes SCSI tape drives:

Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Scalar i500 User’s Guide

293

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 40 Stand-Alone 5U
Control Module SCSI Cabling

Scalar i500 User’s Guide

1

Ethernet cable to customer network

2

GB Ethernet port

3

SCSI terminator

4

Power supply

5

Rear power switch

6

SCSI cable to host

7

Library control blade

8

Module terminators

294

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 41 Multi-Module SCSI
Cabling

1

Module-to-module cable

2

Library control blade

3

GB Ethernet port

4

SCSI terminator

5

Power supply

6

Rear power switch

7

Power cords

8

SCSI cables to host

9

Module terminators

10 Ethernet cable to customer network

Scalar i500 User’s Guide

295

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

1 If your library is larger than 14U, install it in a rack. See Installing the
Library in a Rack on page 417 for instructions. The instructions
include procedures for removing and replacing tape drives.
2 Connect the SCSI cables to the tape drives. There are two
recommended ways to cable SCSI tape drives: one tape drive per
SCSI bus or two tape drives per SCSI bus (see Figure 42).
Note:

To avoid possible performance issues, do not connect
more than two SCSI drives per SCSI bus.

Caution:

The library supports a maximum cable length of 12
meters (including internal wiring) for Ultra 160 SCSI
and Ultra 320 SCSI cables.

To connect one tape drive per SCSI bus:

a Use a SCSI cable to connect the bottom port of the tape drive to
your host.
b Use a SCSI terminator to terminate the top port of the tape drive.
To connect two tape drives per SCSI bus:

a Connect one end of the SCSI cable to the top SCSI port of the
bottom tape drive. Then connect the other end of the cable to the
bottom SCSI port of the tape drive above. The SCSI cable
connecting the two tape drives should be at least 30 cm in length.
b Use another SCSI cable to connect the bottom tape drive of the
SCSI bus to your host.
c Use a SCSI terminator to terminate the top tape drive of the SCSI
bus.

Scalar i500 User’s Guide

296

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 42 Cabling One or Two
Tape Drives Per SCSI Bus
One tape
drive per
SCSI bus

Two tape
drives per
SCSI bus

1

SCSI terminator

2

SCSI drive-to-host cable

3

SCSI cable connecting two SCSI tape
drives

3 Connect the module terminators.
Caution:

The module terminator is not the same as a SCSI
terminator. Using a SCSI terminator instead of a
module terminator will damage the library.

a Using the module terminators, terminate the top and bottom
modules in the library stack. Install one module terminator in the
top terminator connector on the topmost module and one in the
bottom terminator connector on the bottommost module.
If your library configuration consists of a single module, place
module terminators in the module’s top and bottom module
terminator connector.
Scalar i500 User’s Guide

297

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

b If you need to add expansion modules to the control module,
remove the module terminator from the control module
terminator connection that is closest to the expansion module.
c Replace the module terminator in the expansion module in the
terminator connection that is furthest from the control module.
4 Connect the module-to-module cable from the control module to the
expansion module.
5 Connect your Ethernet cable to the Gigabit (GB) Ethernet port on the
library control blade (LCB) for remote access to the library via the
Web client.
6 Connect a power cord to the outlet on the power supply on the rear of
the library.
There should always be a power cord connected to the power supply
on the control module. If redundant power supplies are used,
connect a power cord to each of the additional power supply outlets.
7 Power on the library.
a Turn on the rear power switch of each of the power supplies.
b Turn on the front power button.
c Power up the host system.
8 Verify communication with all devices on the bus.
9 Configure the library using the commands on the operator panel. See
configuration information in Configuring Your Library on page 52.

Cabling Libraries With
SAS Tape Drives
12

Scalar i500 User’s Guide

Each SAS tape drive should be connected directly to the host bus adapter
(HBA) using one SAS cable. The LTO-4 and LTO-5 SAS tape drives in the
Scalar i500 library use the SFF-8088 type SAS connector. The connector
needed on the host end of the cable depends on the type of Host Bus
Adapter (HBA) being used.

298

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Caution:

Quantum sells both SAS-1 and SAS-2 tape drives. SAS-2
technology and the SAS-2 standard allow for increased
connection speed and greater cable lengths when
compared to SAS-1. Quantum recommends the use of
Quantum-qualified cables when using SAS tape drives.
Quantum engineers and qualifies cables specifically to be
compatible with the tape library SAS connection
architecture.

The library does not support daisy-chaining SAS cables. The library does
not support the use of SAS expander devices or cables at this time.
Use this procedure, along with Figure 43 and Figure 44, to connect SAS
cables directly to the host.
Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Scalar i500 User’s Guide

299

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 43 Stand-Alone Control
Module SAS Cabling

Scalar i500 User’s Guide

1

Ethernet cable to network

2

GB Ethernet port

3

Power supply

4

Rear power switch

5

Power cord

6

SAS cable to host

7

Library control blade

8

Module terminators

300

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 44 Multi-Module SAS
Cabling

Scalar i500 User’s Guide

1

Module-to-module cable

2

Library control blade

3

GB Ethernet port

4

Power supply

5

Rear power switch

6

Power cords

7

SAS cables to host

8

Module terminators

9

Ethernet cable to network

301

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

1 If your library is larger than 14U, install it in a rack. See Installing the
Library in a Rack on page 417 for instructions. The instructions
include procedures for removing and replacing tape drives.
2 Connect one end of the SAS cable to the tape drive. Connect the other
end of the SAS cable to the host.
3 If your library configuration consists of a single module, place
module terminators in the module’s top and bottom module
terminator connectors.
Caution:

The module terminator is not the same as a SCSI
terminator. Using a SCSI terminator instead of a
module terminator will damage the library.

4 If the library consists of more than one module, connect the modules
together as follows:
Caution:

The module terminator is not the same as a SCSI
terminator. Using a SCSI terminator instead of a
module terminator will damage the library.

a Using the module terminators, terminate the top and bottom
modules in the library stack. Install one module terminator in the
top terminator connector on the topmost module and one in the
bottom terminator connector on the bottommost module.
b If you need to add expansion modules to the control module,
remove the module terminator from the control module
terminator connection that is closest to the expansion module.
c Replace the module terminator in the expansion module in the
terminator connection that is furthest from the control module.
d Connect the module-to-module cable from the control module to
the expansion module.
5 Connect your Ethernet cable to the Gigabit (GB) Ethernet port on the
library control blade (LCB) for remote access to the library via the
Web client.

Scalar i500 User’s Guide

302

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

6 Connect a power cord to the outlet on the power supply on the rear of
the library.
There should always be a power cord connected to the power supply
on the control module. If redundant power supplies are used,
connect a power cord to each of the additional power supply outlets.
7 Plug the power cord into a nearby AC power source.
8 Power on the library.
a Turn on the rear power switch of each of the power supplies.
b Turn on the front power button.
c Power up the host system.
9 Verify communication with all devices on the bus.
10 Configure the library using the commands on the operator panel. See
configuration information in Configuring Your Library on page 52.

Cabling Libraries With
Fibre Channel Tape
Drives Connected
Directly to a Host or
Switch
12

Scalar i500 User’s Guide

Use this procedure, along with Figure 45 and Figure 46, if you are
installing a library that includes FC tape drives that are connected
directly to a host or switch.

303

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 45 Stand-Alone Control
Module Fibre Channel Cabling

Scalar i500 User’s Guide

1

Ethernet cable to customer network

2

GB Ethernet port

3

Power supply

4

Rear power switch

5

Power cord

6

Fibre cable to host

7

Library control blade (LCB)

8

Module terminators

304

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 46 Multi-Module Fibre
Channel Cabling

Scalar i500 User’s Guide

1

Ethernet cable to network

2

GB Ethernet port

3

Power supply

4

Rear power switch

5

Power cords

6

Fibre cables to host

7

Module terminators

8

Library control blade (LCB)

9

Module-to-module cable

305

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Note:

Pay attention to where the operator panel is positioned in the
rack for optimum usability.

1 If your library is larger than 14U, install it in a rack.
See Installing the Library in a Rack on page 417 for instructions. The
instructions include procedures for removing and replacing tape
drives.
2 Connect the fibre cables to the tape drives.
a Attach one end of the fibre cable to the fibre port on each tape
drive.
b Attach the other end of the cable to the host or switch.
Note:

The fibre cable can be connected from the tape drive to a
switch rather than a host.

3 Connect the module terminators.
Caution:

Scalar i500 User’s Guide

The module terminator is not the same as a SCSI
terminator. Using a SCSI terminator instead of a
module terminator will damage the library.

306

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

a Using the module terminators, terminate the top and bottom
modules in the library stack. Install one module terminator in the
top terminator connector on the topmost module and one in the
bottom terminator connector on the bottommost module.
If your library configuration consists of a single module, place
module terminators in the module’s top and bottom module
terminator connectors.
b If you need to add expansion modules to the control module,
remove the module terminator from the control module
terminator connection that is closest to the expansion module.
c Replace the module terminator in the expansion module
terminator connection furthest from the control module.
4 Connect the module-to-module cable from the control module to the
expansion module.
5 Connect your Ethernet cable to the Gigabit (GB) Ethernet port on the
Library Control Blade (LCB) for remote access to the library via the
Web client.
6 Connect a power cord to the outlet on the power supply on the rear of
the library.
There should always be a power cord connected to the power supply
on the control module. If redundant power supplies are used,
connect a power cord to each of the additional power supply outlets.
7 Power on the library.
a Turn on the rear power switch of each of the power supplies.
b Turn on the front power switch.
c Power up the host system.
8 Verify communication with all devices on the bus.
Configure the library using the commands on the operator panel. See
configuration information in Configuring Your Library on page 52.

Scalar i500 User’s Guide

307

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Cabling Libraries With
Fibre Channel Tape
Drives Connected to
Fibre Channel I/O
Blades
12

These instructions explain how to install the FC cables that connect the
FC drives to the FC I/O blades. The FC I/O blades support connections
to LTO-2, LTO-3, LTO-4, LTO-5 and LTO-6 drives.
Caution:

LTO-5 Fibre Channel tape drives can be configured for
speeds of up to 8 GB per second and support autonegotiation to 8 Gb/s, 4 Gb/s, and 2 Gb/s. If they are
configured for 8 Gb/s, you should connect them directly
to a host or switch and not to an FC I/O blade, because the
FC I/O blade only allows speeds up to 4 Gb/s. If you
connect an LTO-5 Fibre Channel tape drive to an FC I/O
blade, the speed will autonegotiate to 4 Gb/s (see Setting
Tape Drive Parameters on page 83). Speeds less than 2
Gb/s are not supported.

For information on installing FC I/O blades, see Adding, Removing, and
Replacing FC I/O Blades on page 443.
Cabling may be affected by partitioning or zoning changes made as part
of configuration. When cabling to drives, ensure that they are cabled to
the correct hosts for the defined partitions. If the FC I/O blades have
active channel zoning, ensure that the drives are attached to ports that are
accessible to the defined zone. For information on partitioning,
configuring FC I/O blade ports, channel zoning, and host mapping, see
Chapter 3, Configuring Your Library.
Details about cabling FC I/O blades include:
• Each expansion module can support up to two FC I/O blades. A
maximum of four FC I/O blades can be present in any library
configuration. A maximum of four FC drives can be connected to one
FC I/O blade.
• Ports 1 and 2 on each FC I/O blade are reserved for connection to
hosts. Ports 1 and 2 are always in target mode. The other four ports
(3, 4, 5 and 6) are always in initiator mode. See Figure 47.
• Ideally, an installed tape drive should be cabled to a port on the
nearest FC I/O blade to eliminate the need to manage excessively
long cables. The nearest FC I/O blade is usually located in the same
expansion module as the tape drive.

Scalar i500 User’s Guide

308

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Note:

See Cable Management Guidelines on page 316 for bestpractice guidelines for cabling a library.

Figure 47 FC I/O Blade

1

Target ports 1 and 2 to host(s)

2

Initiator ports 3 – 6 to drives

3

LEDs (blue, amber, green)

Use the following procedure, along with Figure 48, if you are installing a
library that includes FC tape drives that are connected to FC I/O blades.

Scalar i500 User’s Guide

309

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Figure 48 FC With I/O Blade
Cabling

Scalar i500 User’s Guide

1

Library control blade (LCB)

7

Module terminator

2

GB Ethernet port

8

FC cable to host

3

Power supplies

9

Module-to-module cable

4

Power cords

10 Ethernet cable to network

5

Ethernet cables from LCB to
expansion module (one per FC I/O
blade)

11 UPPER and LOWER Ethernet
ports

6

FC cable from FC I/O blade to tape
drive

310

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Required tools: None

1 If your library is larger than 14U, install it in a rack. See Installing the
Library in a Rack on page 417 for instructions. The instructions
include procedures for removing and replacing tape drives.
Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Note:

Pay attention to where the operator panel is positioned in the
rack for optimum usability.

2 For each FC I/O blade installed in an expansion module, connect the
expansion module containing the FC I/O blade(s) to a port in the
Ethernet hub on the LCB:
Note:

Without these Ethernet cables connected, the FC I/O
blades will not work.

a If the FC I/O blade is installed in the bottom bay of the expansion
module, connect one end of an Ethernet cable to the Ethernet port
labeled LOWER in the lower right corner of the expansion
module. Connect the other end of the cable to a port in the
Ethernet hub on the LCB.
b If the FC I/O blade is installed in the upper bay of the expansion
module, connect one end of an Ethernet cable to the Ethernet port
labeled UPPER in the lower right corner of the expansion module.
Connect the other end of the cable to a port in the Ethernet hub
on the LCB.
c Follow the instructions in Cable Management Guidelines on
page 316 for best practices in routing the Ethernet cables.

Scalar i500 User’s Guide

311

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

3 Remove and discard the necessary number of the black rubber
protective covers from the ports on the FC I/O blades.
4 Carefully unwrap the FC cables and remove the two white plastic
protective caps from each end of the cable.
Caution:

FC cables will be damaged if they are bent at more than a
four-inch arc.

5 Connect the FC cable to one of the following initiator ports on the FC
I/O blade: 3, 4, 5, or 6. When you choose the port, take into account
the location of any other tape drives that you plan to connect to the
same FC I/O blade. See Cable Management Guidelines on page 316
for best-practice guidelines for cabling a library.
6 Insert the other end of the FC cable into the FC port on the FC tape
drive.
7 Repeat the above steps for each FC drive you want to connect to the
FC I/O blade. Do not connect any of these FC cables to ports 1 or 2 on
the FC I/O blade.
8 Connect the host(s) to ports 1 and/or 2 on the FC I/O blade.
9 Install the module terminators.
Caution:

The module terminator is not the same as a SCSI
terminator. Using a SCSI terminator instead of a
module terminator will damage the library.

a Using the module terminators, terminate the top and bottom
modules in the library stack. Install one module terminator in the
top terminator connector on the topmost module and one in the
bottom terminator connector on the bottommost module.
If your library configuration consists of a single module, place
module terminators in the module’s top and bottom module
terminator connectors.
b If you need to add expansion modules to the control module,
remove the module terminator from the control module
terminator connection that is closest to the expansion module.
c Replace the module terminator in the expansion module
terminator connection furthest from the control module.

Scalar i500 User’s Guide

312

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

10 Connect the module-to-module cable from the control module to the
expansion module.
11 Connect an Ethernet cable to the Gigabit (GB) Ethernet port on the
Library Control Blade (LCB) for remote access to the library via the
Web client.
12 Connect a power cord to the outlet on the power supply on the rear of
the library.
There should always be a power cord connected to the power supply
on the control module. If redundant power supplies are used,
connect a power cord to each of the additional power supply outlets.
13 Power on the library.
a Turn on the rear power switch of each of the power supplies.
b Turn on the front power button.
c Power up the host system.
14 Verify communication with all devices on the bus.
15 Configure the library using the commands on the operator panel. See
configuration information in Configuring Your Library on page 52.

Recommended Library
Fibre optic cables connect Fibre Channel tape drives to FC I/O blades and
Cabling for FC I/O Blades 12 FC I/O blades to a Storage Area Network (SAN) fabric or host. Correctly
managing these cables on the rear of the library can prevent damage to
the cables and Fibre Channel ports and ensure optimal data throughput.
Note:

This section applies to libraries containing Fibre Channel tape
drives, which are connected to a host or a Fibre Channel
switch using an FC I/O blade. For tape drives that are directly
attached to a host or a SAN switch, follow standard fibre optic
cable handling best practices.

Ideally, an installed tape drive should be cabled to a port on the nearest
FC I/O blade to eliminate the need to manage excessively long cables.
The nearest FC I/O blade is usually located in the same expansion
module as the tape drive.
You will need to provide fibre cables long enough to connect a host or a
SAN switch to a target port on an FC I/O blade.

Scalar i500 User’s Guide

313

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

It is important to consider how drives are assigned to partitions when
cabling tape drives and hosts to an FC I/O blade. If you want a host to be
able to communicate with a tape drive that is assigned to a particular
partition, both the drive and the host that has access to the partition
should communicate through the same FC I/O blade.
The following table provides an example of a 41U library with FC I/O
blade-attached tape drives. The information next to the image shows each
tape drive and the FC I/O blade and port to which each tape drive is
connected.

Scalar i500 User’s Guide

314

Chapter 12 Installing, Removing, and Replacing
Cabling the Library

Recommended Cabling With FC I/O
Blades In Maximum Capacity Library

Scalar i500 User’s Guide

FC I/O Blade
Port

Tape Drive

FC I/O Blade

[1,1]

N/A (direct attached)

[1,2]

N/A (direct attached)

[1,3]

[1,2]

Port 3

[1,4]

[1,2]

Port 4

[0,1]

[1,2]

Port 5

[0,2]

[1,2]

Port 6

[-1,1]

[-1,2]

Port 3

[-1,2]

[-1,2]

Port 4

[-1,3]

[-1,2]

Port 5

[-1,4]

[-1,2]

Port 6

[-2,-1]

[-2,-2]

Port 3

[-2,-2]

[-2,-2]

Port 4

[-2,-3]

[-2,-2]

Port 5

[-2,-4]

[-2,-2]

Port 6

[-3,1]

[-3,2]

Port 3

[-3,2]

[-3,2]

Port 4

[-3,3]

[-3,2]

Port 5

[-3,4]

[-3,2]

Port 6

315

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Cable Management Guidelines
As the library expands to support larger configurations, it is important to
restrain and organize cables and power cords on the rear of the library.
Doing so ensures that the rear of the library remains accessible and
reduces the possibility that cables become damaged.
Use this section to find cable management guidelines and best practices
for power cords and Ethernet cables. Use the equipment specified in the
Cable Management Kit section below.

Cable Management Kit 12

Component

Scalar i500 User’s Guide

If you purchase a Fibre Channel I/O blade or an Ethernet Expansion
blade, you will receive a cable management kit with all the equipment
necessary to perform these procedures. You can also order the cable
management kit from http://shop.quantum.com. The color of the straps
matches the color of the cords they are designed to secure.
Description

Quantity

Black hook-and-loop fastener — Secures power cords
to expansion modules.

1

Blue hook-and-loop fastener —Secures Ethernet cables
to expansion modules.

1

316

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Component

Managing Power
Cords

Description

12

Quantity

Push-in clip — to secure hook-and-loop fasteners to
expansion modules.

2

M5 thumbscrew — For older library models without
drilled holes for push-in clips. The M5 thumbscrew
attaches hook-and-loop fasteners to the M5 threaded
hole on the lower right of any module chassis.

2

Push-in wire saddle cable clamp — Secures Ethernet
cables to the control module.

2

Adhesive-backed wire saddle cable clamp — For older
library models without drilled holes for push-in wire
saddle clamps. The adhesive-backed wire saddle
clamp secures Ethernet cables to the control module.

2

Power cord management is important especially for the larger, expanded
library configurations. A 41U library with redundant power (the
maximum configuration) may contain as many as 10 power supply units
with 10 power cords to manage.
To organize power cords on the rear of the library, mount a black hookand-loop fastener to each module and then secure the power cords with
the fastener.
Power cords and power cord hook-and-loop fasteners that are shipped
with the library are black in color.
You can apply the following procedure to any library that contains at
least one expansion module.

Scalar i500 User’s Guide

317

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

To secure a power cord to the library frame:
1 Facing the rear of the library, locate a specific hole that is drilled into
the back of the expansion module for the hook-and-loop fastener.
This hole is located on the rear of the library, about three inches from
the top of the expansion module near the right side of the library
chassis. Refer to the illustration below to locate this hole.
Note:

If your module chassis does not have the drilled hole, use an
M5 thumbscrew to attach the black hook-and-loop fastener to
the nearest available M5 threaded hole on the lower right of
any module chassis.

2 Insert a push rivet into the rivet hole on the black hook-and-loop
fastener. The head of the rivet should be on the same side of the
fastener as the plastic loop.
3 Firmly press the push rivet through the hole in the expansion module
described above. The hook-and-loop fastener should now be secured
to the library chassis.
4 Plug the power cord into a power supply unit closest to the hookand-loop fastener.
5 Determine how much cord length you need to reach and easily plug
into the AC power source. Do not plug the cord into power source
until you are ready to power on the library.
6 If there is excess power cord, loop the excess cord into a bundle in the
shape of a figure-eight. The bundle should be small enough to hold
comfortably with one hand, or about eight inches in length.
7 Wrap the bundle with the hook-and-loop fastener. Thread the strap
through the plastic loop and tighten the strap around the bundled
cord. Secure the strap by pressing it down.
The power cord is now secured to the expansion module. Repeat these
steps to secure other power cords, if necessary. Bundle adjacent power
cords together using the same hook-and-loop fastener.
Once complete, power cord management for a 41U library should look
similar to Figure 49 on page 319.

Scalar i500 User’s Guide

318

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Figure 49 Power Cord
Management

Scalar i500 User’s Guide

319

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Managing Ethernet
Cables

12

A Scalar i500 library with FC I/O blades or Ethernet Expansion blades
uses external Ethernet cables on the rear of the library to provide
connectivity between the LCB in the control module and an expansion
module. The upper and lower FC I/O blade/Ethernet Expansion blade
bays within an expansion module each have a corresponding Ethernet
port on the back of the module. Running an Ethernet cable between this
port and one of the Ethernet hub ports on the LCB establishes Ethernet
connectivity between the blade and the LCB.
The LCB provides ports for up to four Ethernet cables on its internal
Ethernet hub. This allows the library to support a total of four FC I/O
blades and/or Ethernet Expansion blades.
To organize Ethernet cables on the rear of the library, mount two wire
saddles on the control module to route the Ethernet cable(s) to the right
side of the library. Mount a blue hook-and-loop fastener to each module
and then secure the Ethernet cables with the fastener.
Ethernet cables and Ethernet hook-and-loop straps that are shipped with
the library are blue in color.
Apply the following procedure to any library that contains at least one
expansion module and at least one FC I/O blade or Ethernet Expansion
blade.
To secure an Ethernet cable to the library frame using a cable tie:
1 Facing the rear of the library, install the two push-in wire saddle
cable clamps onto the control module chassis. Push the rivet of one
clip into the hole drilled into the cover plate located to the right of the
LCB. Push the rivet of the other clip into the hole located near the
extreme right side of the library, below the control module’s power
supplies. See Figure 50 on page 322 for the locations of these holes.
Note:

If your control module chassis does not have the drilled
holes, use the adhesive -backed wire saddle cable clamps
in the location shown in Figure 50.

2 Locate a specific hole that is drilled into the back of the expansion
module for the hook-and-loop strap. This hole is located on the rear
of the library, about three inches from the bottom of the expansion
module on the right side of the frame back plane. See Figure 50 on
page 322 for the location of this hole.

Scalar i500 User’s Guide

320

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Note:

If your module chassis does not have the drilled hole, use
an M5 thumbscrew to attach the black hook-and-loop
fastener to the nearest available M5 threaded hole on the
lower right of any module chassis.

3 Insert a push rivet into the rivet hole on the blue hook-and-loop
fastener. The head of the rivet should be on the same side of the
fastener as the plastic loop.
4 Firmly press the push rivet through the hole in the expansion module
described above. The hook-and-loop fastener should now be secured
to the library chassis.
5 Plug the one end of the Ethernet cable into one of the four Ethernet
hub ports on the LCB.
6 Plug the other end of the Ethernet cable into the appropriate port on
the expansion module.
If the FC I/O blade is installed in the module’s upper I/O blade bay,
plug the cable into the Ethernet port labeled UPPER. If the FC I/O
blade or Ethernet Expansion blade is installed in the module’s lower
I/O blade bay, plug the cable into the Ethernet port labeled LOWER.
7 Open the wire saddle nearest the LCB, place the Ethernet cable
inside, and snap the wire saddle shut.
8 Repeat for the other wire saddle.
9 If there is excess Ethernet cable, loop the excess cable into a bundle in
the shape of a figure-eight. The bundle should be small enough to
hold comfortably with one hand, or about six inches in length.
10 Wrap the bundle with the hook-and-loop fastener. Thread the strap
through the plastic loop and tighten the strap around the bundled
cable. Secure the strap by pressing it down.
The Ethernet cable is now secured to the expansion module. Repeat these
steps to secure other Ethernet cables, if necessary.
Once complete, the Ethernet cabling for a 41U library containing four FC
I/O blades should appear similar to Figure 50 on page 322.

Scalar i500 User’s Guide

321

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Figure 50 Ethernet Cable
Management

Scalar i500 User’s Guide

322

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Figure 51 shows how a 41U library with FC I/O blades installed would
appear with power, Ethernet, and fibre cables installed and managed
according to these guidelines.

Figure 51 Cable Management,
All Cables, FC I/O Blades
Installed

Scalar i500 User’s Guide

323

Chapter 12 Installing, Removing, and Replacing
Cable Management Guidelines

Figure 52 shows how a 41U library with Ethernet Expansion blades
installed would appear with power, Ethernet, and fibre cables installed
and managed according to these guidelines.

Figure 52 Cable Management,
All Cables, Ethernet Expansion
Blades Installed

Scalar i500 User’s Guide

324

Chapter 12 Installing, Removing, and Replacing
Installing a Stand-Alone 5U Control Module

Installing a Stand-Alone 5U Control Module
Required tools: None

Use this procedure to install a 5U library configuration:
1 Prepare the rack to hold modules, if you want to install your library
in a rack. See Installing the Library in a Rack on page 417 for
instructions on installing a rack-mount kit.
2 Make sure all tape drives have been removed from the control
module. See Adding, Removing, and Replacing Tape Drives on
page 438 for instructions on removing tape drives.
3 Make sure all power supplies have been removed from the control
module. See Adding, Removing, and Replacing Power Supplies on
page 414 for instructions on removing power supplies.
4 Open the library’s I/E station door and access door. Lift the control
module and place it in the desired location.
5 If you are placing the control module in a rack, use the rack ears to
fasten the control module to the rack. For instructions, see Installing
the Bottom Module in the Rack on page 427.
6 If not already installed, install the library control blade (LCB) in the
control module. See Removing and Replacing the Library Control
Blade and LCB Compact Flash Card on page 402 for instructions on
installing the LCB.
7 Add the tape drives to the module.
8 Install the power supplies. See Adding, Removing, and Replacing
Power Supplies on page 414 for instructions on installing power
supplies.
9 Close the library’s I/E station door and access door.
10 Connect all power cords and network data cables. See Cabling the
Library on page 289.
11 Install module terminators in the top and bottom module terminator
connectors. See Cabling the Library on page 289 for information on
installing the module terminators.
12 Power on the library.
13 Configure the library using the operator panel Setup Wizard.
Scalar i500 User’s Guide

325

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

14 Add the tape cartridges to the library using the I/E station.
15 If your host application inventories the location of each tape cartridge
in the library, open the host application and re-inventory to sync the
logical inventory with the physical inventory of the library.

Installing a New Multi-Module Library Configuration
Use this procedure for installing a new multi-module library. A multimodule library contains a control module and up to four expansion
modules.
There are no restrictions on where the control module can be installed in
the library configuration. However, the recommended placement of the
control module for library configurations up to 32U is on top of all
installed 9U expansion modules. The recommended placement of the
control module for 41U library configurations is on top of three 9U
expansion modules and below the top expansion module.
Expansion Module

Control Module
Expansion Module

Expansion Module

Expansion Module

Scalar i500 User’s Guide

326

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Preparing to Install a
Multi-Module Library

12

Required tools:

• Phillips #2 screwdriver, for removing and replacing the top cover
plate
• T10 TORX screwdriver, for removing and replacing the bottom cover
plate
1 Prepare the rack to hold modules, if you want to install your library
in a rack. See Installing the Library in a Rack on page 417 for
instructions on installing a rackmount kit.
2 Make sure all tape drives have been removed from all of the modules
you plan to install. See Adding, Removing, and Replacing Tape
Drives on page 438 for instructions on removing tape drives.
3 Make sure all power supplies have been removed from all of the
modules you plan to install. See Adding, Removing, and Replacing
Power Supplies on page 414 for instructions on removing power
supplies.
4 Park the robot assembly in the control module. Before unstacking the
library, the robot assembly must be placed in the control module.
a Open the I/E station and access doors of each module.
b Using your hands, gently lift the robot assembly into the control
module. The robot assembly should glide slowly and with some
resistance.

Scalar i500 User’s Guide

327

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

Caution:

Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.

c After raising the robot assembly to the approximate middle of the
control module, hold it in place with one hand and, using your
other hand, move the parking tab in a counter-clockwise
direction until it stops in the “parked” position. The metal
parking tab is located at the bottom of column 1.
d Gently lower the robot assembly to rest on the parking tab.

Scalar i500 User’s Guide

328

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

1

Parking tab in “parked” position

5 Remove and replace the cover plates, if appropriate. When removing
the cover plate, ensure that you do not remove the y-home flag screw
as shown in Figure 53 on page 330.
Caution:

Scalar i500 User’s Guide

Before removing the control module’s bottom cover
plate, the robot assembly must be parked as described
in Step 4 above.

329

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

Figure 53 Cover plate with yhome flag

1

2

1

screws to remove

2

y-home flag screw - do not remove

Scalar i500 User’s Guide

330

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

a If you plan to stack the control module at the top of the library,
and if an expansion module will be located below it, remove the
control module’s bottom cover plate and the expansion module’s
top plate.
b If you plan to stack the control module between expansion
modules, remove both the top and bottom plates of the control
module. Also remove the top plate of the expansion module
located below the control module and the bottom plate of the
expansion module located above the control module.
c If you plan to stack the control module at the bottom of the
library, and if an expansion module will be located above it,
remove the control module’s top plate and the expansion
module’s bottom plate.

Figure 54 Recommended
Module Locations

5U

14U

23U

32U

41U
cover plate

cover plate

Expansion
Module

cover plate

Control
Module

Control
Module

cover plate

Control
Module

Expansion
Module

Expansion
Module

cover plate

Control
Module

Expansion
Module

Expansion
Module

Expansion
Module

Control
Module

Expansion
Module

Expansion
Module

Expansion
Module

Expansion
Module

cover plate

cover plate

cover plate

cover plate

cover plate

Scalar i500 User’s Guide

331

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

Installing the Expansion
Module
12

Scalar i500 User’s Guide

Install the expansion module as follows:
1 Open the expansion module’s access door and raise the guide pin by
pulling it up and turning it slightly as if it were a screw. Otherwise,
the guide pin may scratch the front doors of the module on which
you are stacking.

1

Guide pin

2

Thumbscrew

332

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

2 Lift the new expansion module and, from the front of the library,
place it in the desired location.
3 If stacking the expansion module on top of another module, secure
the two modules together by tightening the two thumbscrews at the
base of the front of the module and the two thumbscrews located at
the base of the back of the module. Then lower the module’s guide
pin (located at the base of the front of the module) by turning it and
pushing it down.
4 Tighten all thumbscrews located at the base of the front and back of
the modules.
5 Fasten the module to the rack with rack ears. See Installing the
Library in a Rack on page 417 for information on installing a
rackmount kit.
6 If stacking the expansion module on top of another module, engage
the Y-rails of the new module in your library configuration. Ensure
that the Y-rails are properly aligned and the thumbscrews are
tightened.

Scalar i500 User’s Guide

333

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

334

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

a From the front of the library, open the I/E station and access
doors of the expansion module. Squeeze the handle of the Y-rail
release mechanism, lift it out of its locked position, and slide it
downward as far as it will go.
b From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
Caution:

Check to make sure that there is no gap between the top
and bottom Y-rails on both the front and back of the
library. If a gap exists, the library cannot mechanically
initialize.

Doing this aligns the Y-rails with the Y-rails of the module beneath it.

Figure 55 Y-Rail in Unlocked,
Functional Position

7 Repeat these steps for each expansion module you are installing.
Scalar i500 User’s Guide

335

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

Installing the Control
Module

12

Install the 5U control module as follows:
1 Open the control module’s I/E station door and access door.
2 Lift the control module and place it in the desired location.
3 If stacking the control module on top of another module, secure the
two modules together by tightening the two thumbscrews at the base
of the front of the module and the two thumbscrews located at the
base of the back of the module. Then lower the module’s guide pin
(located at the base of the front of the module) by turning it and
pushing it down.
4 Tighten all thumbscrews located at the base of the front and back of
the modules.
5 Use the rack ears to fasten the control module to the rack.
6 If not already installed, install the library control blade (LCB) in the
control module. See Removing and Replacing the Library Control
Blade and LCB Compact Flash Card on page 402 for instructions on
installing the LCB.

Preparing to Use the
Multi-Module Library

12

Prepare the library for use as follows:
1 Unpark the robot assembly.
a Gently raise the robot assembly so that it no longer rests on the
parking tab.
Caution:

Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.

b With your free hand, move the parking tab in a clockwise
direction until it stops in the “unparked” position. When in the
correct position, the parking tab is removed completely from the
interior of the module and will not accidentally swing into the
path of the robot.
c Gently release the robot assembly. It will lower to the bottom
module of the library.

Scalar i500 User’s Guide

336

Chapter 12 Installing, Removing, and Replacing
Installing a New Multi-Module Library Configuration

1

Parking tab in “unparked” position

2 Close the library’s I/E station and access doors.
3 Add the tape drives to the modules. For details, see Adding,
Removing, and Replacing Tape Drives on page 438.
4 If your library contains FC I/O blades, install both the I/O blades
and the accompanying fan blades in the expansion module. For
details, see and Adding, Removing, and Replacing the FC I/O Fan
Blade on page 454.

Scalar i500 User’s Guide

337

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

5 Add the power supplies.For details, see Adding, Removing, and
Replacing Power Supplies on page 414.
6 Connect all power cords, network data cables, and module-tomodule cables. Make sure the module terminators are installed at the
top and bottom of the stack of modules. For cabling instructions, see
Cabling the Library on page 289.
7 Power on the library. For libraries larger than a 14U, boot time may
take 15-20 minutes.
8 Configure the library using the Setup Wizard that appears on the
operator panel interface.
9 Add the tape cartridges to the library’s modules using the I/E station
commands from the operator panel or Web client.
10 Open the host application and reinventory in order to synchronize its
logical inventory with the physical inventory of the library.

Adding Expansion Modules to an Existing Library
Adding expansion modules to the library increases the number of data
cartridges available within the library system. These instructions explain
how to add an expansion module to an existing library.
Note:

The maximum number of expansion modules supported in a
library depends on the level of firmware the library is running.
The latest firmware must be installed on the library if you are
upgrading from a 5U or 14U configuration to a larger
configuration. The latest firmware can be found at
www.quantum.com/support. See Updating Library and Tape
Drive Firmware on page 278 for more information.

There are some configuration settings to take into account when adding
an expansion module to an existing library.
• All COD licenses remain the same. If the current license key does not
cover the expanded capacity, you will need a new license key to use
the newly available slots.

Scalar i500 User’s Guide

338

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

• Partition, I/E station slot, and cleaning slot assignments do not
change; however, unassigned slots may change location.
• Modifying partitions can cause the storage slots to be scattered
throughout the library.
• I/E station slots in the new module(s) are assigned as data storage
slots. You can reconfigure these slots as I/E station slots after the
expansion module has been added to the library.
A library can use up to four expansion modules to a maximum height of
41U.
There are no restrictions on where the control module can be installed in
the library configuration. However, the recommended placement of the
control module for library configurations up to 32U is on top of all
installed expansion modules. The recommended placement of the control
module for 41U library configurations is on top of three expansion
modules and below the top expansion module.
When adding additional expansion modules to an existing library
configuration, the recommended placement of the new expansion
module is at the bottom of the existing library configuration (except for
the 41U, where recommended placement is on top). Installing the new
expansion module at the bottom of the existing library configuration will
logically assign slot numbering within the library.
Expansion
Module

Control
Module
Expansion
Module

Expansion
Module

Expansion
Module

Scalar i500 User’s Guide

339

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Warning:

Without tape drives, tape cartridges, or power supplies, a
5U control module weighs approximately 60 lbs (27.2 kg).
A 9U expansion module, without tape drives, tape
cartridges, or power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.

Preparing to Install an
Additional Expansion
Module
12

Prepare to install an additional expansion module as follows:
Warning:

Without tape drives, tape cartridges, or power supplies, a
5U control module weighs approximately 60 lbs (27.2 kg).
A 9U expansion module, without tape drives, tape
cartridges, or power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.

Caution:

Scalar i500 User’s Guide

If the library contains a partition that spans modules, and
you plan to install the new expansion module between
those modules, you must delete the partition before
adding the new module, and re-create the partition after
installing the module.

340

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Required tools:

• Phillips #2 screwdriver, for removing and replacing the top cover
plate
• T10 TORX screwdriver, for removing and replacing the bottom cover
plate
You need to unstack the library to install the new expansion module at
the bottom of the new library configuration.
1 Upgrade the library firmware to a level that can support the number
of modules you are adding. See Updating Library and Tape Drive
Firmware on page 278 for information on upgrading firmware.
2 If you have a partition that spans modules, and you plan to add the
new expansion module between those modules, you must delete the
partition before adding the new module (see Deleting Partitions on
page 74).
3 Remove all tape cartridges from the library using the import and
export commands of the operator panel or Web client.
4 Power off the library.
5 Disconnect all power cords, network data cables, and module-tomodule cables from all of the modules.
Note:

You should label all cables before you remove them so you
can later reconnect them to their proper locations.

6 Park the robot assembly in the control module. Before unstacking the
library, the robot assembly must be placed in the control module.
a Open the I/E station and access doors of each module.
b Using your hands, gently lift the robot assembly into the control
module. The robot assembly should glide slowly and with some
resistance.
Caution:

Scalar i500 User’s Guide

Support the robot assembly by holding onto the
broad metal X-axis plate. Lifting the robot by the
thin metal rod will bend the rod. Lifting the robot
by the black plastic picker body can damage the
robot.

341

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

c After raising the robot assembly to the approximate middle of the
control module, hold it in place with one hand and, using your
other hand, move the parking tab in a counter-clockwise
direction until it stops in the “parked” position. The metal
parking tab is located at the bottom of column 1.
d Gently lower the robot assembly to rest on the parking tab.

1

Parking tab in “parked” position

7 Remove all power supplies from each module.
8 Remove all tape drives from each module.
Scalar i500 User’s Guide

342

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Unstacking the Existing
Modules
12

Unstack the modules as follows:
1 Starting with the topmost module of your library, open the I/E
station and access doors.
Caution:

Before unstacking the modules, the robot
assembly must be parked as described in
Preparing to Install an Additional Expansion
Module above.

2 If your current configuration already uses an expansion module,
disengage the Y-rails so the modules can be safely unstacked.
a From the front of the library, find the Y-rail release mechanism,
which is located on the left side of the module. Squeeze the
handle of the Y-rail release mechanism, lift it, and release it so
that it locks into place.
b From the rear of the library, find the rear Y-rail release
mechanism located in the interior of the right side of the module.
Squeeze the handle of the Y-rail release mechanism, lift it, and
release it so that it locks into place.
Note:

Scalar i500 User’s Guide

The rear Y-rail is impossible to lift up with the tape drives
installed.

343

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

344

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

3 Remove the rack ears that fasten the module to the rack.
4 Loosen the thumbscrews located at the base of the front and rear of
the module.

1

Scalar i500 User’s Guide

Thumbscrews (behind doors)

345

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

5 Open the module’s access door and raise the guide pin by pulling it
up and turning it slightly as if it were a screw. Otherwise, the guide
pin may scratch the front doors of the module beneath it.

1

Guide pin

2

Thumbscrew

6 From the front of the library, slide the entire module toward you and
lift it off of the module below it.
7 Repeat these steps for each module that you need to remove.

Scalar i500 User’s Guide

346

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Installing the New 9U
Expansion Module
12

Install the new 9U expansion module as follows:
1 Prepare the rack to hold modules, if you want to install your library
in a rack. See Installing the Library in a Rack on page 417 for
instructions on installing a rackmount kit.
2 Remove and replace the cover plates, if appropriate.
Caution:

Before removing the control module’s bottom cover plate,
the robot assembly must be parked as described in
Preparing to Install an Additional Expansion Module
above.

a If you plan to stack the control module at the top of the library,
and if an expansion module will be located below it, remove the
control module’s bottom cover plate and the expansion module’s
top plate.
b If you plan to stack the control module between expansion
modules, remove both the top and bottom plates of the control
module. Also remove the top plate of the expansion module,
located below the control module, and the bottom plate of the
expansion module, located above the control module.
c If you plan to stack the control module at the bottom of the
library, and if an expansion module will be located above it,
remove the control module’s top plate and the expansion
module’s bottom plate.

Scalar i500 User’s Guide

347

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Figure 56 Cover Plate Location
After Adding an Expansion
Module

5U

14U

23U

32U

41U
cover plate

cover plate

NEW Expansion
Module*

cover plate

Control
Module

Control
Module

cover plate

Control
Module

Expansion
Module

Expansion
Module

cover plate

Control
Module

Expansion
Module

Expansion
Module

Expansion
Module

Control
Module

NEW Expansion
Module*

NEW Expansion
Module*

NEW Expansion
Module*

Expansion
Module

cover plate

cover plate

cover plate

cover plate

cover plate

* Recommended location for adding an expansion module.

3 Open the expansion module’s access door and raise the guide pin by
pulling it up and turning it slightly as if it were a screw. Otherwise,
the guide pin may scratch the front doors of the module on which
you are stacking it.

Scalar i500 User’s Guide

348

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Scalar i500 User’s Guide

1

Guide pin

2

Thumbscrew

349

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

4 Lift the new expansion module and, from the front of the library,
place it in the desired location.
5 If there is already a module installed, secure the two modules
together by tightening the two thumbscrews at the base of the front of
the module and the two thumbscrews located at the base of the back
of the module. Then lower the module’s guide pin (located at the
base of the front of the module) by turning it and pushing it down.
6 Tighten all thumbscrews located at the base of the front and back of
the modules.
7 Fasten the module to the rack with rack ears.
8 Engage the Y-rails of the new module in your library configuration.
Ensure that the Y-rails are properly aligned and the thumbscrews are
tightened.

Scalar i500 User’s Guide

350

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

351

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

a From the front of the library, open the I/E station and access
doors of the expansion module.
b Squeeze the handle of the Y-rail release mechanism, lift it out of
its locked position, and slide it downward as far as it will go.
c From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
Doing this aligns the Y-rails with the Y-rails of the module
beneath it.
Caution:

Scalar i500 User’s Guide

Check to make sure that there is no gap between the top
and bottom Y-rails on both the front and back of the
library. If a gap exists, the library cannot mechanically
initialize.

352

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

1

Y-rail in unlocked, functional position

9 Repeat these steps for each module you need to re-install in the
library configuration.

Preparing to Use the
Library

12

Prepare to use the library as follows:
1 Add the tape drives to the modules. For details, see Adding,
Removing, and Replacing Tape Drives on page 438.
2 Add the power supplies. For details, see Adding, Removing, and
Replacing Power Supplies on page 414.
3 Add the LCB to the control module. For details, see Removing and
Replacing the Library Control Blade and LCB Compact Flash Card on
page 402.

Scalar i500 User’s Guide

353

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

4 If your library contains FC I/O blades, install both the I/O blades
and the accompanying fan blades in the expansion module. For
details, see Adding, Removing, and Replacing FC I/O Blades on
page 443 and Adding, Removing, and Replacing the FC I/O Fan
Blade on page 454.
5 Unpark the robot assembly.
a Gently raise the robot assembly so that it no longer rests on the
parking tab.
Caution:

Support the robot assembly by holding onto the
broad metal X-axis plate. Lifting the robot by the
thin metal rod will bend the rod. Lifting the robot
by the black plastic picker body can damage the
robot.

b With your free hand, move the parking tab in a clockwise
direction until it stops in the “unparked” position. When in the
correct position, the parking tab is removed completely from the
interior of the module and will not accidentally swing into the
path of the robot.
c Gently release the robot assembly. It will lower to the bottom
module of the library.

Scalar i500 User’s Guide

354

Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library

1

Parking tab in “unparked” position

6 Connect all power cords, network data cables, and module-tomodule cables. Make sure the module terminators are installed at the
top and bottom of the stack of modules. For cabling instructions, see
Cabling the Library on page 289.
7 Power on the library.
8 Reconfigure the library, including applying the new COD license
key, using the operator panel or Web client.
9 Recreate any partitions you deleted prior to installing the module.
Scalar i500 User’s Guide

355

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

10 Add the tape cartridges to the library’s modules using the I/E station
commands from the operator panel or Web client.
11 Open the host application and reinventory in order to synchronize its
logical inventory with the physical inventory of the library. Due to
the way the library logically addresses its tape drives and slots
internally, adding an expansion module will change the element
addresses, and this can affect proper communication to a controlling
host. See Understanding Logical Element Addressing on page 35.
Because of this, you must refresh the configuration of any backup
application that manages the library to reflect the adjusted positions.
In addition, you may need to reboot the host server(s) or rescan the
bus to detect the changes.

Preparing to Remove or Replace a Module
Follow the instructions in this section before performing any of the
following procedures:
• Permanently Removing Expansion Modules From an Existing
Library on page 364
• Replacing the Control Module on page 376
• Replacing an Expansion Module on page 388

Caution:

If a control module is replaced, all library configuration
data will be invalidated and requires a new library
configuration. Follow the instructions below to completely
export all tape cartridges and completely delete all logical
partition configuration and cleaning slot assignments.

Caution:

If an expansion module is removed or replaced, you must

follow the steps below to modify or delete all the affected
partitions before removing the module. Recreate the
partitions after the removal or replacement is complete.

Scalar i500 User’s Guide

356

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

Required tools:

• Phillips #2 screwdriver, for removing and replacing the top cover
plate
• T10 TORX screwdriver, for removing and replacing the bottom cover
plate
Instructions:

1 View your library’s current configuration before removing or
replacing any library modules to determine which partitions may be
affected, which tape cartridges belong to which partition, and
whether cleaning slots are configured within the library module you
are removing or replacing. See Viewing the Library Configuration
Report on page 268.
For example, in Figure 57, the following library configuration may be

observed. Note that there are three partitions configured. All three
partitions share six I/E elements in the control module. The library is
configured for automatic cleaning and has three cleaning slots
configured in the expansion module.

Scalar i500 User’s Guide

•

Library_a configured all storage elements in the control module,
and has one drive configured in the control module, and one
drive configured in the expansion module.

•

Library_b configured most storage elements in the control
module, but references its last storage element in the expansion
module. This partition has one drive configured in the control
module and one drive configured in the expansion module.

•

Library_c configured all storage elements in the expansion
module, and also configured two drives in this expansion
module.

357

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

Figure 57 Library Configuration
Example 1

2 If cleaning slots are configured for automatic, library–initiated
cleaning operations, export all affected cleaning media from the
elements contained within the module you are removing or
replacing. See Exporting Cleaning Media on page 258.
3 If cleaning slots are affected and all cleaning media has been
exported from the module you are removing or replacing, reduce or
delete the cleaning slots so that cleaning slots are no longer
configured within the module you are removing or replacing. You
Scalar i500 User’s Guide

358

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

can designate new cleaning slots after the module has been removed
or replaced. See Configuring Cleaning Slots on page 78.
4 If the module you are removing or replacing contains tape drives,
make sure that none of the tape drives have media mounted. See
Unloading Tape Drives on page 252.
5 If the module you are removing or replacing contains I/E slots,
remove all media from the affected I/E slots and store them
separately for each partition so you can import them back into the
same partition once the module removal or replacement is complete.
6 If one or more partitions reference any storage slots within the
module you are removing or replacing, export all tape cartridges
from the affected partitions and keep the exported cartridges
separated by partition, so you can import them back into the same
partition once the module removal or replacement is complete. See
Exporting Media on page 249.
Caution:

The library will not be able to locate tape cartridges
that are removed from one partition and returned to a
different partition. The tape cartridges must be
returned to the same partition from which they were
removed.

7 If a partition references storage slots within the module you are
removing or replacing, delete such partition. You can create new
partitions after modules have been removed or replaced. See
Working With Partitions on page 68.

Scalar i500 User’s Guide

359

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

Note:

If the last elements of a partition reside in the module you
are removing or replacing, you may be able to modify the
partition instead of deleting it. (See Understanding Logical
Element Addressing on page 35 for more information on
how the library logically addresses tape drives and slots.)
In that case, you would 1) export those tape cartridges that
reside in the module you are removing or replacing, and 2)
modify the partition, instead of deleting it, so that the
partition no longer references any storage or drive
elements within the module you are removing or
replacing. See Modifying Partitions on page 73.
For example, in Figure 58, after exporting all affected tape

cartridges from the module you are removing, the cleaning
slots are deleted, then Library_c is completely deleted, and
Library_b is modified to reduce its storage slot count by
one, as this deletes the storage slot reference in the
expansion module. No storage element modifications are
required for Library_a.

Scalar i500 User’s Guide

360

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

Figure 58 Library Configuration
Example 2

8 If a partition references tape drives within the module you are
removing or replacing, modify any affected partition by removing
the referenced drive elements from the partition. See Modifying
Partitions on page 73.
For example, in Figure 57 on page 358, all partitions reference drives
in the expansion modules. In Figure 58 on page 361, Library_c was
deleted, as well as its drive references in the expansion module.

Scalar i500 User’s Guide

361

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

Library_a and Library_b still require partition modifications to
remove the drive reference and hereby free the expansion module of
all partition resource references.
9 If you are removing or replacing an expansion module, set the
number of I/E station slots to six. You can reconfigure I/E station
slots after the module removal or replacement is complete. See
Configuring I/E Station Slots on page 79.
10 Power off the library.
11 Disconnect all power cords, network data cables, and module-tomodule cables from each module you will be removing.
Note:

You should label all cables before you remove them so you
can later reconnect them to their proper locations.

12 Park the robot assembly in the control module. Before unstacking the
library, the robot assembly must be placed in the control module.
a Open the I/E station and access doors of each module.
b Using your hands, gently lift the robot assembly into the control
module. The robot assembly should glide slowly and with some
resistance.
Caution:

Support the robot assembly by holding onto the
broad metal X-axis plate. Lifting the robot by the
thin metal rod will bend the rod. Lifting the robot
by the black plastic picker body can damage the
robot.

c After raising the robot assembly to the approximate middle of the
control module, hold it in place with one hand and, using your
other hand, move the parking tab in a counter-clockwise
direction until it stops in the “parked” position. The metal
parking tab is located at the bottom of column 1.
d Gently lower the robot assembly to rest on the parking tab.

Scalar i500 User’s Guide

362

Chapter 12 Installing, Removing, and Replacing
Preparing to Remove or Replace a Module

1

Parking tab in “parked” position

13 Remove all power supplies from each module that you intend to
remove. For details, see Adding, Removing, and Replacing Power
Supplies on page 414.
14 Remove all tape drives from each module that you intend to remove.
If you are going to replace the module, label the drives with their
locations so you can re-install them in the same locations later. For
details, see Adding, Removing, and Replacing Tape Drives on
page 438.

Scalar i500 User’s Guide

363

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

15 If the module you are removing or replacing contains FC I/O blades,
remove both the I/O blades and the accompanying fan blades from
the expansion module. For details, see Adding, Removing, and
Replacing FC I/O Blades on page 443 and Adding, Removing, and
Replacing the FC I/O Fan Blade on page 454.
16 Before removing a module, you must first remove all expansion
modules (if any) positioned above it. Disconnect all power cords,
network data cables, and module-to-module cables from the module
you are removing or replacing and all modules located above it. Then
remove the modules.
Warning:

Without tape drives, tape cartridges, or power
supplies, a control module weighs approximately 60
lbs (27.2 kg). An expansion module, without tape
drives, tape cartridges, or power supplies, exceeds 65
lbs (29.5 kg).
To avoid serious injury, at least two people are
required to safely lift the modules.

Note:

If the library is installed in a rack, you need to perform
additional steps to remove modules from and place
modules into the rack. See Installing the Library in a Rack
on page 417 for more information.

Permanently Removing Expansion Modules From an
Existing Library
These instructions explain how to permanently remove an expansion
module from the library.
There are some configuration settings to take into account when
removing an expansion module from an existing library.
• COD licenses remain the same. After the expansion module is
removed, there may be more slots licensed than are available. Only
the available slots appear on the License screen.
Scalar i500 User’s Guide

364

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

• All resources in the removed module(s) are removed. A partition
with all resources in the removed module(s) will be present with no
slots or drives. This partition can only be deleted.
Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Warning:

Without tape drives, tape cartridges, or power supplies, a
5U control module weighs approximately 60 lbs (27.2 kg).
A 9U expansion module, without tape drives, tape
cartridges, or power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.

Removing the Expansion
Module
12

To remove the expansion module:
1 Before removing a module, follow the instructions in Preparing to
Remove or Replace a Module on page 356.
2 For each module that you plan to remove, open the I/E station and
access doors of each module.
Caution:

Before unstacking the modules, the robot assembly must
be parked as described in Preparing to Remove or Replace
a Module on page 356.

3 Disengage the Y-rails so the modules can be unstacked safely.

Scalar i500 User’s Guide

365

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

366

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

a From the front of the library, find the Y-rail release mechanism,
which is located on the left side of the control module. Squeeze
the handle of the Y-rail release mechanism, lift it, and release it so
that it locks into place.
b From the rear of the library, find the rear Y-rail release
mechanism located in the interior of the right side of the module.
Squeeze the handle of the Y-rail release mechanism, lift it, and
release it so that it locks into place.

1

Y-rail in locked, non-functional
position

4 Remove the rack ears that fasten the module to the rack. See
Installing the Library in a Rack on page 417 for detailed instructions
on using the rack ears.
5 Loosen the thumbscrews located at the base of the front of the
module.
Scalar i500 User’s Guide

367

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

1

Thumbscrews (behind doors)

6 Loosen the two thumbscrews located at the base of the back of the
module.
Scalar i500 User’s Guide

368

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

7 Open the module’s access door and raise the guide pin by pulling it
up and turning it slightly as if it were a screw. Otherwise, the guide
pin may scratch the front doors of the module beneath it.
8 From the front of the library, slide the entire module toward you and
lift it off of the module below it.
9 Repeat these procedures for each module that you intend to remove.
10 Remove and replace the cover plates, if appropriate (see Figure 59).
Caution:

Before removing the control module’s bottom cover
plate, the robot assembly must be parked as described
in Preparing to Remove or Replace a Module on
page 356.

a If you plan to stack the control module at the top of the library,
and if an expansion module will be located below it, remove the
control module’s bottom cover plate and the expansion module‘s
top plate.
b If you plan to stack the control module between expansion
modules, remove both the top and bottom plates of the control
module. Also remove the top plate of the expansion module
located below the control module and the bottom plate of the
expansion module located above the control module.
c If you plan to stack the control module at the bottom of the
library, and if an expansion module will be located above it,
remove the control module’s top plate and the expansion
module’s bottom plate.

Scalar i500 User’s Guide

369

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

Figure 59 Cover Plate Location
After Removing an Expansion
Module

5U

14U

23U

32U
cover plate

cover plate

Control
Module

cover plate

Control
Module

Expansion
Module

cover plate

Control
Module

Expansion
Module

Expansion
Module

Control
Module

Expansion
Module

Expansion
Module

Expansion
Module

cover plate

cover plate

cover plate

cover plate

Preparing to Use the New
Library Configuration 12

Scalar i500 User’s Guide

Prepare to use the new library configuration as follows:
1 Ensure that the Y-rails are properly aligned and the thumbscrews are
tightened.

370

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

371

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

a From the front of the library, open the I/E station and access
doors of the expansion module. Squeeze the handle of the Y-rail
release mechanism, lift it out of its locked position, and slide it
downward as far as it will go.
b From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
Doing this aligns the Y-rails with the Y-rails of the module
beneath it.
Caution:

Scalar i500 User’s Guide

Check to make sure that there is no gap between the top
and bottom Y-rails on both the front and back of the
library. If a gap exists, the library cannot mechanically
initialize.

372

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

1

Y-rail in unlocked, functional position

2 Add the tape drives to the modules. For details, see Adding,
Removing, and Replacing Tape Drives on page 438.
3 Add the power supplies. For details, see Adding, Removing, and
Replacing Power Supplies on page 414.
4 If your library contains FC I/O blades, install both the I/O blades
and the accompanying fan blades in the expansion module. For
details, see Adding, Removing, and Replacing FC I/O Blades on
page 443 and Adding, Removing, and Replacing the FC I/O Fan
Blade on page 454.
5 Unpark the robot assembly.
a Gently raise the robot assembly so that it no longer rests on the
parking tab.

Scalar i500 User’s Guide

373

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

Caution:

Support the robot assembly by holding onto the
broad metal X-axis plate. Lifting the robot by the
thin metal rod will bend the rod. Lifting the robot
by the black plastic picker body can damage the
robot.

b With your free hand, move the parking tab in a clockwise
direction until it stops in the “unparked” position. When in the
correct position, the parking tab is removed completely from the
interior of the module and will not accidentally swing into the
path of the robot.
c Gently release the robot assembly. It will lower to the bottom
module of the library.

Scalar i500 User’s Guide

374

Chapter 12 Installing, Removing, and Replacing
Permanently Removing Expansion Modules From an Existing Library

1

Parking tab in “unparked” position

6 Close the library’s I/E station and access doors.
7 Connect all power cords, network data cables, and module-tomodule cables. Make sure the module terminators are installed at the
top and bottom of the stack of modules. For cabling instructions, see
Cabling the Library on page 289.
8 Power on the library.
9 Re-create and/or modify partitions, cleaning slots, and I/E station
slots as desired.
Scalar i500 User’s Guide

375

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

10 Import tape cartridges to the correct library partitions as needed.
11 Save the library configuration (see Saving the Library Configuration
on page 489.
12 If the host application inventories the location of each tape cartridge
in the library, open the host application and reinventory in order to
sync its logical inventory with the physical inventory of the library.
Due to the way the library logically addresses its tape drives and slots
internally, permanently removing an expansion module from the
library will change the element addresses, and this can affect proper
communication to a controlling host. See Understanding Logical
Element Addressing on page 35. Because of this, you must refresh the
configuration of any backup application that manages the library to
reflect the adjusted positions. In addition, you may need to reboot
the host server(s) or rescan the bus to detect the changes.

Replacing the Control Module
These instructions explain how to remove a control module and replace it
with a control module field replaceable unit (FRU). You may need to
replace the control module if its chassis is severely damaged. Typically,
however, only certain customer replaceable units (CRUs) or FRUs within
the control module need to be replaced.
There are some configuration settings to take into account when
replacing the control module.
• If you have applied one or more license keys to the original control
module, you will need to replace each license key and apply it to the
new control module. For more information, see Obtaining and
Installing a License Key on page 88.
• A partition with all resources in the removed module will be present
with no slots or drives. This partition can only be deleted.
There are no restrictions on where the control module can be installed in
the library configuration. However, the recommended placement of the
control module for library configurations up to 32U is on top of all
installed expansion modules. The recommended placement of the control

Scalar i500 User’s Guide

376

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

module for 41U library configurations is on top of three expansion
modules and below the top expansion module.

Removing the Control
Module
12

1 Before removing a module, follow the instructions in Preparing to
Remove or Replace a Module on page 356.
2 Starting with the topmost module of your library, open the I/E
station and access doors of the module.
Caution:

Before unstacking the modules, the robot
assembly must be parked as described in
Preparing to Remove or Replace a Module on
page 356.

3 Disengage the Y-rails so the modules can be safely unstacked.
a From the front of the library, find the Y-rail release mechanism,
which is located on the left side of the module. Squeeze the
handle of the Y-rail release mechanism, lift it, and release it so
that it locks into place.
b From the rear of the library, find the rear Y-rail release
mechanism located in the interior of the right side of the module.
Squeeze the handle of the Y-rail release mechanism, lift it, and
release it so that it locks into place.
Note:

Scalar i500 User’s Guide

The rear Y-rail is impossible to lift up with the tape
drives installed.

377

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

4 Remove the rack ears that fasten the module to the rack.
5 Loosen the thumbscrews located at the base of the front and rear of
the module.

Scalar i500 User’s Guide

378

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

Scalar i500 User’s Guide

1

Control module (front)

2

Thumbscrews

3

Control module (rear)

379

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

6 Open the module’s access door and raise the guide pin by pulling it
up and turning it slightly as if it were a screw. Otherwise, the guide
pin may scratch the front doors of the module beneath it.

1

Guide pin

2

Thumbscrew

7 Slide the entire module toward you and lift it off of the module below
it.

Replacing the Control
Module
12

1 If not already removed, remove the tape drives and power supplies
from the control module you are replacing.
2 Using the Phillips #2 screwdriver (for the top cover plate) and the
T10 TORX screwdriver (for the bottom cover plate), remove the new
control module plates from the top and bottom of the module, as
necessary.

Scalar i500 User’s Guide

380

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

Caution:

Before removing the control module’s bottom cover
plate, the robot assembly must be parked as described
in Preparing to Remove or Replace a Module on
page 356.

a If your library consists of only the control module, do not remove
the plates.
b If you plan to stack the control module at the top of the library,
and if an expansion module is located below it, remove the
control module’s bottom cover plate.
c If you plan to stack the control module in the middle of the
library, remove both the top and bottom cover plates.
d If you plan to stack the control module at the bottom of the
library, and if an expansion module is located above it, remove
the control module’s top cover plate.
3 Remove the LCB from the removed control module and set it aside.
The LCB stores information about the library’s contents and
configuration, so you will probably want to install this LCB (or
possibly just the LCB compact flash card) in the new control module.
For details about removing the LCB, see Removing and Replacing the
Library Control Blade and LCB Compact Flash Card on page 402.
Note:

If you plan to stack the control module on top of a 9U
expansion module, be sure to park the robot in the control
module first.

4 If the library configuration includes expansion modules below the
control module, install them in the library now.
5 Install the new control module in the library. Lift the control module
and, from the front of the library, place it in the desired location.
Place the control module on top of the expansion module and slide it
to the rear of the unit. A small notch on the bottom of the control
module aligns it with the top of the 9U expansion module.
6 Use rack ears to fasten the control module on top of a 9U expansion
module.

Scalar i500 User’s Guide

381

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

7 If you placed the control module on top of an expansion module,
secure the two modules by tightening the two thumbscrews at the
base of the front of the module and the two thumbscrews located at
the base of the back of the module. Then lower the module’s guide pin
(located at the base of the front of the module) by turning it and
pushing it down.
8 Stack all expansion modules (if any) in their original positions above
the control module. Use rack ears to fasten the modules to the
rack.Then tighten all thumbscrews located at the base of the front and
back of the modules.
9 Engage the Y-rails. Tighten the thumbscrews and lower the guide
pin. Doing this aligns the Y-rail with the Y-rail of the module beneath
it.
a From the front of the library, open the I/E station and access
doors of the control module. Squeeze the handle of the Y-rail
release mechanism, lift it out of its locked position, and slide it
downward as far as it will go.

Scalar i500 User’s Guide

382

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

1

Y-rail in unlocked, functional position

b From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
10 Unpark the robot assembly.
a Gently raise the robot assembly so that it no longer rests on the
parking tab.
Caution:

Scalar i500 User’s Guide

Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.

383

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

b With your free hand, move the parking tab in a clockwise
direction until it stops in the “unparked” position. When in the
correct position, the parking tab is removed completely from the
interior of the module and will not accidentally swing into the
path of the robot.
c Gently release the robot assembly. It will lower to the bottom
module of the library.

1

Scalar i500 User’s Guide

Parking tab in “unparked” position

384

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

Preparing to Use the
Control Module

12

1 Close the library’s I/E station and access doors.
2 Add the tape drives to the modules. For details, see Adding,
Removing, and Replacing Tape Drives on page 438.
3 Add the power supplies. For details, see Adding, Removing, and
Replacing Power Supplies on page 414.
4 Install the LCB or compact flash card from the removed control
module in the new control module. For details, see Removing and
Replacing the Library Control Blade and LCB Compact Flash Card on
page 402.
5 Connect all power cords, network data cables, and module-tomodule cables. Make sure the module terminators are installed in
their previous positions at the top and bottom of the stack of
modules. For cabling instructions, see Cabling the Library on
page 289.
6 Power on the library.
7 Re-create and/or modify partitions, cleaning slots, and I/E station
slots as desired.
8 Import tape cartridges into the correct partitions as needed.
9 Save the library configuration (see Saving the Library Configuration
on page 489.
10 If the host application inventories the location of each tape cartridge
in the library, open the host application and reinventory in order to
sync its logical inventory with the physical inventory of the library.
Due to the way the library logically addresses its tape drives and slots
internally, replacing a control module may change the element
addresses, and this can affect proper communication to a controlling
host. See Understanding Logical Element Addressing on page 35.
Because of this, you must refresh the configuration of any backup
application that manages the library to reflect the adjusted positions.
In addition, you may need to reboot the host server(s) or rescan the
bus to detect the changes.

Scalar i500 User’s Guide

385

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

Special Instructions for
Replacing a Control
Module in a Library
Running SKM
12

If your library is running SKM, you must you run a special script on the
SKM server after you replace the control module. The script will correct
the library serial number associations in the key server database and
allow you to export used SKM encryption keys via the Web client
correctly. For instructions, refer to the chapter titled “Updating the SKM
Keystore After Replacing a Library Control Module” in the Scalar Key
Manager 2.0 User’s Guide.
When running the script, you will need to enter the serial numbers of
both the non-functioning control module as well as the serial number of
the new replacement control module. Before you send the control module
back to Quantum, record the serial numbers so you can provide them
when required. If you have already returned the failed control module to
Quantum, contact Quantum Support to obtain its serial number.
Locating the Serial Number on the Scalar i500

12

On the Scalar i500, the serial number label is located inside the control
module, on the horizontal bar at the back of the library. To see the label,
open the front door. See Figure 4 for location and Figure 61 for an
example.
The serial number is listed first. The serial number is all of the characters
following the “%SN” on the serial number label. Do not enter the “%SN”
characters when typing the serial number into the SKM command line.

Scalar i500 User’s Guide

386

Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module

Figure 60 Scalar i500 Serial
Number Label On Control
Module Seen Through Open
Front Door

Scalar i500 User’s Guide

387

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

Figure 61 Scalar i500
SN/WWN Label

You can also find the serial number on the library as follows:
• Operator panel — Select Tools > About Library.
• Web client — Select Reports > System Information. The serial
number is in the Physical Library table in the Serial Number
column.

Replacing an Expansion Module
These instructions explain how to remove and replace an expansion
module. You may need to replace the expansion module if its chassis is
severely damaged.
A library can use up to four expansion modules to a maximum height of
41U.
There are some configuration settings to take into account when
removing and replacing an expansion module.
• COD licenses remain the same. After the expansion module is
removed, there may be more slots licensed than are available. Only
the available slots appear on the License screen.
• All resources in the removed module(s) are removed. A partition
with all resources in the removed module(s) will be present with no
slots or drives. This partition can only be deleted.
Note:

Scalar i500 User’s Guide

The maximum number of expansion modules supported
in a library depends on the level of firmware the library is
running. See Updating Library and Tape Drive Firmware
on page 278 for more information.
388

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding)
terminal, and power must be supplied via an
industrial plug and socket-outlet and/or an appliance
coupler complying with IEC 60309 (or an equivalent
national standard) and having a protective earth
(ground) conductor with a cross sectional area of at
least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60
cm (24 inches) in the front and back of the library.

Warning:

Without tape drives, tape cartridges, or power
supplies, a control module weighs approximately 60
lbs (27.2 kg). An expansion module, without tape
drives, tape cartridges, or power supplies, exceeds 65
lbs (29.5 kg).
To avoid serious injury, at least two people are
required to safely lift the modules.

Scalar i500 User’s Guide

389

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

Removing the 9U
Expansion Module

12

1 Before removing the module, follow the instructions in Preparing to
Remove or Replace a Module on page 356.
2 Starting with the topmost module of your library, open the I/E
station and access doors of each module.
Caution:

Before unstacking the modules, the robot assembly
must be parked as described in Preparing to Remove
or Replace a Module on page 356.

3 Disengage the Y-rails so the modules can be unstacked safely.

Scalar i500 User’s Guide

390

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

391

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

a From the front of the library, find the Y-rail release mechanism,
which is located on the left side of the control module. Squeeze
the handle of the Y-rail release mechanism, lift it, and release it so
that it locks into place.

1

Y-rail in locked, non-functional
position

b From the rear of the library, find the rear Y-rail release
mechanism located in the interior of the right side of the module.
Squeeze the handle of the Y-rail release mechanism, lift it, and
release it so that it locks into place.
4 Remove the rack ears that fasten the module to the rack. See
Installing the Library in a Rack on page 417 for detailed instructions
on using the rack ears.
5 Loosen the thumbscrews located at the base of the front of the
module.
Scalar i500 User’s Guide

392

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

1

Thumbscrews (behind doors)

6 Loosen the two thumbscrews located at the base of the back of the
module.
Scalar i500 User’s Guide

393

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

7 Open the module’s access door and raise the guide pin by pulling it
up and turning it slightly as if it were a screw. Otherwise, the guide
pin may scratch the front doors of the module beneath it.
8 From the front of the library, slide the entire module toward you and
lift it off of the module below it.
9 Repeat these procedures for each module that you need to remove.
10 Remove and replace the cover plates, if appropriate.
Caution:

Before removing the control module’s bottom cover
plate, the robot assembly must be parked as described
in Preparing to Remove or Replace a Module on
page 356.

a If you plan to stack the control module at the top of the library,
and if a 9U expansion module will be located below it, remove
the control module’s bottom cover plate and the 9U expansion
module’s top plate.
b If you plan to stack the control module between 9U expansion
modules, remove both the top and bottom plates of the control
module. Also remove the top plate of the 9U expansion module
located below the control module and the bottom plate of the 9U
expansion module located above the control module.
c If you plan to stack the control module at the bottom of the
library, and if a 9U expansion module will be located above it,
remove the control module’s top plate and the 9U expansion
module’s bottom plate.

Replacing the 9U
Expansion Module

12

1 Remove all tape drives from the expansion module that you are
adding. See Adding, Removing, and Replacing Tape Drives on
page 438 for instructions on removing tape drives.
2 Remove the power supplies from the expansion module that you are
adding. See Adding, Removing, and Replacing Power Supplies on
page 414 for instructions on removing power supplies.
3 Open the expansion module’s access door and raise the guide pin by
pulling it up and turning it slightly as if it were a screw. Otherwise,
the guide pin may scratch the front doors of the module on which
you are stacking it.

Scalar i500 User’s Guide

394

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

1

Guide pin

2

Thumbscrew

4 Lift the new expansion module and, from the front of the library,
place it in the desired location.

Scalar i500 User’s Guide

395

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

5 Fasten the module to the rack with rack ears.
6 Secure the two modules together by tightening the two thumbscrews
at the base of the front of the module and the two thumbscrews
located at the base of the back of the module. Then lower the
module’s guide pin (located at the base of the front of the module) by
turning it and pushing it down.
7 Tighten all thumbscrews located at the base of the front and back of
the modules.
8 Engage the Y-rails of each module in your library configuration.
Ensure that the Y-rails are properly aligned and the thumbscrews are
tightened.

Scalar i500 User’s Guide

396

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

Scalar i500 User’s Guide

1

Front Y-rail

2

Rear Y-rail

3

Y-rail (this end up)

4

Squeeze here to release

397

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

a From the front of the library, open the I/E station and access
doors of the expansion module. Squeeze the handle of the Y-rail
release mechanism, lift it out of its locked position, and slide it
downward as far as it will go.

1

Y-rail in unlocked, functional position

b From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
Doing this aligns the Y-rails with the Y-rails of the module
beneath it.

Scalar i500 User’s Guide

398

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

Caution:

Check to make sure that there is no gap between the
top and bottom Y-rails on both the front and back of
the library. If a gap exists, the library cannot
mechanically initialize.

9 Unpark the robot assembly.
a Gently raise the robot assembly so that it no longer rests on the
parking tab.
Caution:

Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.

b With your free hand, move the parking tab in a clockwise
direction until it stops in the “unparked” position. When in the
correct position, the parking tab is removed completely from the
interior of the module and will not accidentally swing into the
path of the robot.
c Gently release the robot assembly. It will lower to the bottom
module of the library.

Scalar i500 User’s Guide

399

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

1

Preparing to Use the 9U
Expansion Module
12

Parking tab in “unparked” position

1 Close the library’s I/E station and access doors.
2 Add the tape drives to the modules. For details, see Adding,
Removing, and Replacing Tape Drives on page 438.
3 Add the power supplies. For details, see Adding, Removing, and
Replacing Power Supplies on page 414.

Scalar i500 User’s Guide

400

Chapter 12 Installing, Removing, and Replacing
Replacing an Expansion Module

4 If your library contains FC I/O blades, install both the I/O blades
and the accompanying fan blades in the expansion module. For
details, see Adding, Removing, and Replacing FC I/O Blades on
page 443 and Adding, Removing, and Replacing the FC I/O Fan
Blade on page 454.
5 Connect all power cords, network data cables, and module-tomodule cables. Make sure the module terminators are installed at the
top and bottom of the stack of modules. For cabling instructions, see
Cabling the Library on page 289.
6 Power on the library.
7 Re-create partitions, cleaning slots, and I/E station slots as desired.
8 Import tape cartridges to the correct partitions as needed.
9 Save the library configuration (see Saving the Library Configuration
on page 489.
10 If the host application inventories the location of each tape cartridge
in the library, open the host application and reinventory in order to
sync its logical inventory with the physical inventory of the library.

Scalar i500 User’s Guide

401

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

Removing and Replacing the Library Control Blade and
LCB Compact Flash Card
The library control blade (LCB) manages the entire library, including the
operator panel and robot, and is responsible for running system tests to
ensure that the library is functioning properly.
The LCB compact flash card contains important information about your
library configuration. If you replace the compact flash card, then you
need to reconfigure your library. You have two options:
• Replacing the LCB/Compact Flash Card or Compact Flash Card
Only
• Replacing the LCB Only
Contact Quantum Support to determine which component(s) you need to
replace and which set of instructions to follow.

Replacing the
LCB/Compact Flash Card
or Compact Flash Card
Only
12

Contact Quantum Support to help you determine whether to replace the
LCB and compact flash card together, or to replace just the compact flash
card. The instructions for both options are nearly identical, except that for
a compact flash card-only replacement, you will reuse the existing LCB
and replace only the compact flash card within it. You will still need to
upgrade firmware as described below.

Equipment Required

12

• Ethernet Cable.
• Host PC or laptop connected to the Scalar i500 library.
• Current Scalar i500 library firmware file saved to your host PC or
laptop. Contact Quantum Support for the firmware, if needed.Latest
library configuration saved on PC or laptop.

Scalar i500 User’s Guide

402

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

Instructions

12

The Compact Flash Card is new and has never been initialized. It contains
only a minimal level of library firmware which allows the library to boot
up and display an Upgrade Notification message. Once you install the
LCB/compact flash card, you will need to upgrade firmware and
reconfigure your network settings.

Note:

Do not separate the old compact flash card from the library
control blade (unless you are replacing the compact flash card
only). Return the old LCB/compact flash card as a pair to
Quantum.

1 If possible, save the library configuration (see Saving the Library
Configuration on page 489).
2 Power off the library.
3 Disconnect all cables from the existing LCB. You may want to label
each cable that is connected to the existing LCB to make sure that you
can correctly reconnect them to the new LCB.
4 Remove the existing LCB from the library.
To remove the existing LCB, release both of the LCB latch hooks and,
using the latch hooks as handles, pull the entire LCB toward you.

Scalar i500 User’s Guide

403

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

1

LCB compact flash card

5 If the new LCB and compact flash card came in discrete packages,
insert the new compact flash card into the new LCB (or, if replacing
the compact flash card only, remove the existing compact flash card
and install the new one in the existing LCB).
6 Insert the new LCB into the vacant LCB slot on the back of the library.
When inserting the new LCB into the slot, be sure that the LCB LEDs
are located at the top of the blade, and that the latch hooks are on the
right side of the blade.
When sliding the new LCB into the slot, there should be no
resistance.

Scalar i500 User’s Guide

404

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

Caution:

Do not force the LCB into the slot or damage may
occur.

7 After inserting the new LCB, secure it by depressing both of the LCB
latch hooks into the blade. The LCB will fit snugly into its slot.
8 Reconnect all cables to the new LCB.
9 Power on the library.
The green power light on the front panel turns on. The screen may
remain dark for up to 5 minutes. Then an “Initialization In Progress”
screen displays. The initialization process can take up to 30 minutes
depending on library configuration.

Caution:

From this point forward until the process is complete,
do NOT remove power from the library! Doing so
may cause failure and cause LCB to become unusable.

When initialization is complete, the screen will display “Upgrade
Notification: Compact Flash Replacement” screen shown below.

Scalar i500 User’s Guide

405

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

10 Click OK.
The login screen appears.
11 Enter the following default user name and password:

Scalar i500 User’s Guide

•

User name: admin

•

Password: password

406

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

12 Press OK.
The Enable IPv6 screen appears.

13 Select the Enable IPv6 check box if you are required to use IPv6 or
leave the check box blank to not enable it.

Scalar i500 User’s Guide

407

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

14 Press Next.
The Network Configuration screen appears. The system defaults to
DHCP. For IPv4 only, you can deselect the DHCP option and assign a
static IP address. You cannot assign a static IP address for IPv6.

15 Accept the default settings by pressing Apply, or make any changes to
the network settings, and then press Apply.
The progress window displays a “Success” message when complete.

Scalar i500 User’s Guide

408

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

16 Press Close.
The next screen lists one or more IP addresses assigned to the library.
17 Write down the IP addresses. You will need them to log in from your
Web browser.
18 Click Close.
The system logs you out and you return to the login screen.

Caution:

The installation is NOT complete at this point.
Install current library firmware following the
steps below. Firmware Installation can take up to
1 hour to complete. DO NOT remove power from
the library during this process.

19 Open a Web browser on the host PC and type the following in the
address bar:
http:///
where ipaddress is one of the IP addresses assigned to the library that
you wrote down earlier.
A screen appears, displaying the current version of library firmware.

Scalar i500 User’s Guide

409

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

20 Click the Click here to upgrade your library’s firmware link.
The Tools - Update Library Firmware screen appears.

21 Click Browse to retrieve the .tgz firmware file from the location on
your computer, then click Apply.
A dialog box appears asking you to confirm it is OK to reboot the
library.
22 Click OK.
The screen displays “WORKING” in the Progress Window.

Scalar i500 User’s Guide

410

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

Once the Firmware has been transferred from the computer to the
library the login screen appears.

Caution:

The appearance of the login screen on the Web
browser does NOT mean the firmware upgrade has
completed on the library; it is just an indication that
the firmware image has been moved to the
LCB/compact flash card. A 14U library with six tape
drives installed can take up to 50 minutes to complete
this process. Actual time may vary. You will not be
able to log in until the firmware upgrade is complete.

Caution:

Do NOT remove power from the library while the
firmware is upgrading.

The library operator panel may display the following “upgrade in
progress” message; or it may blank out or change multiple times
during the firmware upgrade process.

23 When the firmware upgrade is complete, the login screen appears on
the operator panel.

Scalar i500 User’s Guide

411

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

24 Enter the following default user name and password:
•

User name: admin

•

Password: password

25 Press OK.
The Setup Wizard screen appears.
Note:

At this point the Scalar i500 Library is set up with factory
default settings.

26 Reconfigure your library settings as they were before.
Caution:

Replacing the LCB Only12

Contact Quantum Support before restoring the
configuration. In general, it is recommended that you
use the setup wizard to manually reconfigure the
library. It is not recommended to use the “restore
configuration” tool to restore the previous settings.
Doing so will completely reinstall the former library
firmware level and potentially any defective
configuration settings encountered prior to installing
the new LCB/compact flash card combo. If you do
restore a previous configuration and downrev
firmware, you will need to install the latest version of
firmware again.

These instructions explain how to replace the LCB while reusing the
existing LCB compact flash card.
Required tools: None

1 Power off the library.
2 Access the back of the library and locate the existing LCB.
3 Disconnect all cables from the existing LCB. You may want to label
each cable that is connected to the existing LCB to make sure that you
can correctly reconnect them to the new LCB.
4 Remove the existing LCB from the library.
To remove the existing LCB, release both of the LCB latch hooks and,
using the latch hooks as handles, pull the entire LCB toward you.
5 Remove the existing LCB compact flash card from the existing LCB.

Scalar i500 User’s Guide

412

Chapter 12 Installing, Removing, and Replacing
Removing and Replacing the Library Control Blade and LCB Compact Flash Card

1

LCB compact flash card

6 Insert the existing LCB compact flash card into the new LCB.
7 Insert the new LCB (with existing LCB compact flash card) into the
vacant LCB slot on the back of the library.
When inserting the new LCB into the slot, be sure that the LCB LEDs
are located at the top of the blade, and that the latch hooks are on the
right side of the blade.
When sliding the new LCB into the slot, there should be no
resistance.
Caution:

Scalar i500 User’s Guide

Do not force the LCB into the slot or damage may
occur.

413

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Power Supplies

8 After inserting the new LCB, secure it into the control module by
depressing both of the LCB latch hooks into the blade. The LCB will
fit snugly into its slot.
9 Reconnect all cables to the new LCB.
10 Power on the library.
The green power light on the front panel turns on. The screen may
remain dark for up to 5 minutes. Then an “Initialization In Progress”
screen displays.
11 Check the status of the LCB LEDs. All of its LEDs (blue, amber, and
green) should be solidly lit for a short period of time.

Adding, Removing, and Replacing Power Supplies
Library power is controlled at the individual power supplies and at the
front panel of the library. The switch on the rear of each power supply
shuts down power at the input of the individual power supplies. The
switch on the front of the control module provides power to all control
module and 9U expansion module power supplies. You can also turn off
library power using the Web client, if necessary.

Adding a Redundant
Power Supply

12

These instructions explain how to add a second (redundant) power
supply to a module. You may need to add a redundant power supply to
the library to make sure that the library does not go down (and become
inaccessible) if its original power supply happens to fail. The library
automatically uses the redundant power supply if the first power supply
fails for any reason.
Note:

The control module and each expansion module with drives
must use at least one power supply. You can add a redundant
power supply to each module.
Installing one power supply in one module and another power
supply in another module does not provide redundant power;
the two power supplies must reside within the same module.

Scalar i500 User’s Guide

414

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Power Supplies

Required tools: None

1 Save the library configuration (see Saving the Library Configuration
on page 489).
2 Locate the vacant power supply slot and remove the cover plate. Save
the cover plate in case the redundant power supply needs to be
removed at a later date.
3 Insert the new power supply into the vacant slot.
4 When inserting the power supply, make sure that you insert it
correctly with its on/off switch located at the bottom of the supply,
below the handle. The power supply must be level to slide in
smoothly.
5 Tighten the power supply’s thumbscrews to secure the power supply
to the library module.
6 Plug in the power supply cord.
7 Turn on the power supply’s power, using the switch on the rear of
the power supply.
8 Check the status of the power supply’s LEDs. The top green LED and
the blue LED should be solidly lit.
9 Power on the library.
10 Check the status of the power supply’s LEDs. The two green LEDs
should be solidly lit, and the blue LED should be off.

Permanently Removing a
Redundant Power
Supply
12

These instructions explain how to remove a redundant power supply
from the control module. You may need to remove the second power
supply if it is no longer necessary for the library.
Required tools: None

1 Save the library configuration (see Saving the Library Configuration
on page 489).
2 Access the back of the library, and locate the power supply that you
want to replace.
3 Turn off the power supply’s power, using the switch on the rear of
the power supply.
4 Disconnect the power supply cord from the power supply and from
its source.

Scalar i500 User’s Guide

415

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Power Supplies

5 Loosen the power supply’s thumbscrews.
6 Remove the power supply by gripping the power supply handle and
pulling it toward you.
7 Install a cover plate over the vacant power supply slot.

Removing and Replacing
a Power Supply
12

These instructions explain how to remove a power supply and replace it
with a new one. You may need to replace a power supply if there are
problems with one that is currently in use.
If the library has a redundant power supply, you can replace the power
supply without powering off the library. If the library has only one power
supply, you must power off the library before performing this procedure.
Required tools: None

1 Save the library configuration (see Saving the Library Configuration
on page 489).
2 If the library does not use a second (redundant) power supply, power
off the library.
3 Access the back of the library, and locate the power supply that you
want to replace.
4 Turn off the power supply’s power, using the switch on the rear of
the power supply.
5 Disconnect the power supply’s power cord.
6 Loosen the power supply’s thumbscrews.
7 Remove the power supply by gripping the power supply handle and
pulling it toward you.
8 Insert the new power supply into the vacant power supply slot.
When inserting the power supply, make sure that you insert it
correctly with its on/off switch located at the bottom of the supply,
below the handle. The power supply must be level to slide in
smoothly.
9 Tighten the power supply’s thumbscrews to secure the power supply
to the library module.
10 Reconnect the power supply’s power cord.
11 Turn on the power supply’s power.

Scalar i500 User’s Guide

416

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

12 Check the status of the power supply’s LEDs. The top green LED and
the blue LED should be solidly lit.
13 Power on the library.
14 Check the status of the power supply’s LEDs. The two green LEDs
should be solidly lit, and the blue LED should be off.

Installing the Library in a Rack
All Scalar i500 libraries taller than 14U must be installed in a rack. The
rack secures the bottom module, and all other modules are then secured
to the bottom module.
The rackmount kit secures your library within a rack. These instructions
explain how to install your stand-alone library into a rack and how to
install additional modules into an existing rack.
Installing the modules into the rack requires at least two people.
Warning:

All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm2 (14 AWG).
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.

Warning:

Scalar i500 User’s Guide

Under no circumstances should a rack be moved while
loaded with one or more modules.

417

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Warning:

Without tape drives, tape cartridges, or power supplies, a
control module weighs approximately 60 lbs (27.2 kg). An
expansion module, without tape drives, tape cartridges, or
power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.

Note:

Preparing for
Installation

12

The rackmount kit cannot be used with every type of rack.
Racks with threaded rails or unique hole spacing, for example,
may not support the rackmount kit. In addition, the rack must
have rail spacing (front to rear) of between 605 mm (23.8 in.)
and 770 mm (30.3 in.).

Required tools: None

1 Before beginning installation, verify the contents of the rackmount kit
(see Table 9) and the rack ear kit (see Table 10).

Table 9 Rackmount Kit
Contents

Scalar i500 User’s Guide

•

You only need one rackmount kit per library. The rackmount kit
allows you to secure the bottom module in the rack. It includes
rack ears for additional security.

•

You need one rack ear kit for each additional module. Each rack
ear kit contains the supplies to install right and left rack ears on
one module.

•

You must install one set of rack ears for each module in the rack.

Component

Description

Quantity

Small ferrule — Used in
racks with round holes

10 (8
required;
2 spares)

418

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Component

Scalar i500 User’s Guide

Description

Quantity

Large ferrule — Used in
racks with square holes

10 (8
required;
2 spares)

Thumbnut — Secures
the rack shelves to the
rack

8

M5 thumbscrew —
Secures the rack ears

4

Rack ear, left — Holds
the modules in the rack

1

419

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Component

Scalar i500 User’s Guide

Description

Quantity

Rack ear, right — Holds
the modules in the rack

1

Rack shelf, left —
Secures the modules in
the rack

1

Rack shelf, right—
Secures the modules in
the rack

1

420

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Table 10 Rack Ear Kit
Contents

Scalar i500 User’s Guide

Component

Description

Quantity
Required

Nut clip — Used in
racks with square holes

4

Cage nut — Used in
racks with round holes

4

M5 thumbscrew —
Secures the rack ears

4

Rack ear, left — Holds
the modules in the rack

1

421

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Component

Description
Rack ear, right — Holds
the modules in the rack

Quantity
Required
1

2 Remove all rack hardware that may interfere with the installation of
the rackmount kit and the modules that you plan to add to the rack.
3 Consider removing the front and back doors of the rack to obtain full
access to the mounting holes and other areas of the rack.
4 Determine the type of rack in which you plan to install the rackmount
kit. Different racks require different rackmount parts. Although the
rackmount kit contains many parts, the parts you use depend on
your rack’s mounting holes.
a If the rack has round mounting holes, use the small ferrules and
the nut clips.
b If the rack has square mounting holes, use the large ferrules and
the cage nuts.
c If the rack has threaded (tapped M6) holes, do not use the
ferrules, nut clips, or cage nuts.
5 Determine where in your rack you want to install the rackmount
shelves.
Consider installing the shelves at a height that puts the base of the
control module anywhere between the 28U-32U alignment markers,
which is usually a comfortable height for reading the operator panel.
Remember, the control module can be placed anywhere within the

Scalar i500 User’s Guide

422

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

library configuration above, below, or between any expansion
modules. However, for recommended configuration, see Installing a
New Multi-Module Library Configuration on page 326.

Installing the Rackmount
Shelves
12

Required parts: Rackmount shelves, (8) ferrules, (8) thumbnuts

1 If the rackmount shelves are extended, collapse them to their smallest
size. It is easier to fit and position the shelves within the rack when
the shelves are compact.
Note:

Extending the shelves can be difficult, but they are
designed to be resized by hand. Do not use tools to resize
the shelves, and never take them apart.

2 Place a ferrule on the end of each stud, and screw it on completely.
The larger side of the ferrule should face the rack shelf, and the
tapered end should face out. Be sure to use the proper size ferrule as
described in Preparing for Installation on page 418.

Scalar i500 User’s Guide

1

Stud

2

Ferrule

423

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

3 Install the rackmount shelves into the rack so that they are level with
one another.
a Install the shelf’s rear studs in the rack’s rear mounting holes.

b Position the shelf to the appropriate side of the rack (right or left)
and align the shelf at the desired height.
c Insert the shelf’s rear studs into the rack’s rear mounting holes.
d Fasten a thumbnut to the end of each stud. Secure the rack
tightly, so that the ferrule fits snugly within the hole in the rack.
e Next, install the shelf’s front studs in the rack’s front mounting
holes.

Scalar i500 User’s Guide

424

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

f If the studs do not reach the mounting holes, pull the front of the
shelf toward you to extend it to the necessary length. Hold the
base of the shelf with one hand, and pull the extensible part of the
shelf with your other hand.
Note:

Extending the shelves can be difficult, but they are
designed to be resized by hand. Do not use tools to
resize the shelves, and never take them apart.

g Insert the shelf’s front studs into the rack’s front mounting holes.
h Fasten a thumbnut to the end of each stud. Secure the rack
tightly, so that the ferrule fits snugly within the hole in the rack.
4 Visually make sure that both shelves are level, and that they are
aligned properly within the rack.
5 Make sure that all thumbnuts are fastened tightly. Some thumbnuts
may have loosened during installation.

Scalar i500 User’s Guide

425

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Preparing Modules for
Rack Installation
12

1 Power off your library and disconnect all power cords, network data
cables, and module-to-module cables.
2 Remove all tape cartridges, tape drives, power supplies, and all cords
and cables from the library modules. The modules are much easier to
lift into the rack without the additional weight of the tape drives.
Warning:

Without tape drives, tape cartridges, or power
supplies, a control module weighs approximately 60
lbs (27.2 kg). An expansion module, without tape
drives, tape cartridges, or power supplies, exceeds 65
lbs (29.5 kg).
To avoid serious injury, at least two people are
required to safely lift the modules.

3 Park the robot assembly in the control module. (Regardless of which
module you are installing, the robot must be parked in the control
module before you begin moving the modules into the rack.)
a Open the I/E station and access doors of each module.
b Using your hands, gently lift the robot assembly into the control
module. The robot assembly should glide slowly and with some
resistance.
Caution:

Support the robot assembly by holding onto the broad
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.

c After raising the robot assembly to the approximate middle of the
control module, hold it in place with one hand and, using your
other hand, move the parking tab in a counter-clockwise
direction until it stops in the “parked” position. The metal
parking tab is located at the bottom of column 1.
d Gently lower the robot assembly to rest on the parking tab.

Scalar i500 User’s Guide

426

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

1

Installing the Bottom
Module in the Rack

Scalar i500 User’s Guide

12

Parking tab in “parked” position

Required parts: Rack ears, (4) M5 thumbscrews
Explanation of parts: Each rack ear contains two elongated holes, enabling
you to fasten it to the rack (using the M5 thumbscrews) in the most
accessible mounting holes.

427

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

1 Place the desired module (whichever module you want to be the
bottom module of the library) onto the rack-mount shelves. From the
front of the rack, lift the module onto the shelf and gently slide it into
the rack. Slide the module to the back of the rack, so that the front of
the module is flush with the mounting holes.
2 From the back of the rack, secure the module to the rack-mount
shelves by tightening the two silver thumbscrews that are attached to
the rear of the rack-mount shelves.
3 Install the right rack ear. At the front of the library:
a Open the I/E station door. At the lower right corner of the
module is a vertical slot. Insert the hinge of the right rack ear into
the slot and then position the holes of the rack ear flush with the
rack rail.

1

Hinge of rack ears

b Using two M5 thumbscrews, fasten the rack ear to the rack. The
thumbscrews should thread through the holes in the rack shelves
and fasten completely and evenly.

Scalar i500 User’s Guide

428

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

4 Install the left rack ear.
a With the I/E station door open, open the left door (the access
door) of the module and locate the slot in the lower left corner of
the module. (The flexible door hinge allows the door to be pulled
away from the module, providing access to the slot.)
Note:

You may need to pull the door toward you in order to
access the slot.

b Install the left rack ear in the same manner as the right rack ear.
c Using two M5 thumbscrews, fasten the rack ear to the rack. The
thumbscrews should thread through the holes in the rack shelves
and fasten completely and evenly.

Scalar i500 User’s Guide

429

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

5 If you are only installing one module (a control module5U Library
Control Module), unpark the robot assembly now. For instructions,
see step 1 on page 336. If you are installing more modules, proceed to
the next step and do not unpark the robot assembly yet.
6 Close the module’s doors.
7 Install the remaining modules of your library (if any), following the
instructions in Installing Additional Modules Into the Rack on
page 431.
8 Reinstall the tape drives, power supplies, and tape cartridges in the
library.
9 Cable your library as necessary, following the instructions provided
in Cabling the Library on page 289.
10 Power on the library.

Scalar i500 User’s Guide

430

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Installing Additional
Modules Into the Rack 12

All modules that you add to the rack must be positioned above the
module that you previously installed, since the bottom module must be
secured to the rackmount shelves (unless you decide to uninstall the
entire library from the rack and reconfigure it).
Required parts: Rack ears, (4) M5 thumbscrews, (4) nut clips or (4) cage

nuts

Explanation of parts: Each rack ear contains two elongated holes, enabling
you to fasten it to the rack (using the M5 thumbscrews and either the nut
clips or cage nuts) using the most accessible mounting holes.

1 If you are installing a module above a module that currently has a top
cover, remove the top cover. Similarly, if the module you are
installing has a bottom cover, remove the bottom cover before
installing the module above another module in the rack. You need to
make sure the library is “hollow” all the way through with just one
bottom cover on the lowest module and one top cover on the top
module. See Installing the New 9U Expansion Module on page 347.
2 Determine where in the rack to install the nut clips (or cage nuts).
Note:

Consider using the following method to determine where
to install the nut clips (or cage nuts) rather than adding the
module to the rack first. If you add the module to the rack
first, installing the nut clips (or cage nuts) can be difficult
because rack space has become restricted.

a If you are adding a module above a previously racked expansion
module, count nine full units from the location of the expansion
module’s rack ears, and prepare to install the nut clip (or cage
nut) to that location on the rack.
For example, if the expansion module’s rack ears are located at
1U and 2U, then the nut clips (or cage nuts) should be installed at
10U and 11U.
Next, determine which holes you must use within the 10U and
11U markers. Notice that each rack unit (U), as delineated by the
alignment markers in the rack, contains three mounting holes. If
you are adding a module anywhere above the control module,
position the nut clip (or cage nut) at the middle hole in that unit.
If you are adding a module anywhere below the control module,
position the nut clip (or cage nut) at the upper hole in that unit.

Scalar i500 User’s Guide

431

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

b If you are adding a module directly above a previously racked
control module, count five full units from the location of the
control module’s rack ears, and prepare to install the nut clip (or
cage nut) to that location on the rack.
For example, if the control module’s rack ears are located at 1U
and 2U, then the nut clips (or cage nuts) should be installed at 6U
and 7U.
Next, determine which holes you must use within the 6U and 7U
markers. Notice that each rack unit, as delineated by the
alignment markers in the rack, contains three mounting holes. If
you are adding a module anywhere above the control module,
position the nut clip (or cage nut) at the middle hole in that unit.
If you are adding a module anywhere below the control module,
position the nut clip (or cage nut) at the upper hole in that unit.
3 Install the nut clips (or cage nuts) to the desired location in the rack.
Installing nut clips:

a Hold the nut clip so that its semi-circle design faces outside the
rack.
b Push the nut clip onto the rack’s mounting holes so that the nut is
behind the rack’s holes. (After the nut clip is installed, you can
slide it up and down the mounting holes, if necessary.)
Installing cage nuts:

a Hold the cage nut so that its hinges face outside the rack, and so
that its hinges clasp the upper and lower portions of the square
hole.
b Place the cage nut in the desired hole. Insert one hinge in the hole
first, then pinch the cage nut and push it into the hole until it
snaps into place. (You may want to use a screwdriver to help
push the hinge into the hole.)
4 Prepare the module to be stacked in the rack.
a Power off the module and disconnect all power cords, network
data cables, and module-to-module cables.
b Consider removing all tape drives from the module. Modules are
much easier to lift into the rack without the additional weight of
the tape drives.

Scalar i500 User’s Guide

432

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

c Open the module’s access door and raise the guide pin by pulling
it up and turning it slightly as if it were a screw. Otherwise, the
guide pin may scratch the front doors of the module on which
you are stacking it.

1

Guide pin

2

Thumbscrew

5 Lift the module, align it so that it is parallel with the module below it,
and slide it into place.
6 Lower the module’s guide pin by turning it and pushing it down.
7 Secure the module to the module beneath it by tightening the
thumbscrews located at the base of the front and back of the module.
Press down the thumbscrew, and then tighten it.

Scalar i500 User’s Guide

433

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

Scalar i500 User’s Guide

1

Control module (front)

2

Thumbscrews

3

Control module (rear)

434

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

8 Install the right rack ear. At the front of the library:
a Open the I/E station door. At the lower right corner of the
module is a vertical slot. Insert the hinge of the right rack ear into
the slot and then position the holes of the rack ear flush with the
rack rail.

1

Hinge of rack ears

b Using two M5 thumbscrews, fasten the rack ear to the rack. The
thumbscrews should thread through the nut clips (or cage nuts)
and fasten completely and evenly.

Scalar i500 User’s Guide

435

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

9 Install the left rack ear.
a With the I/E station door open, open the left door (the access
door) of the module and pull the door toward you in order to
access the slot located in the lower left corner of the module. (The
flexible door hinge allows the door to be pulled away from the
module, providing access to the slot.)
Note:

You may need to pull the door toward you in order to
access the slot.

b Install the left rack ear in the same manner as the right rack ear.
c Using two M5 thumbscrews, fasten the rack ear to the rack. The
thumbscrews should thread through the nut clips (or cage nuts)
and fasten completely and evenly.

Scalar i500 User’s Guide

436

Chapter 12 Installing, Removing, and Replacing
Installing the Library in a Rack

10 Close the module’s doors.
11 Reinstall the tape drives to the library.
12 Cable your library as necessary, following the instructions provided
in Cabling the Library on page 289.
13 Power on the library.

Scalar i500 User’s Guide

437

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Tape Drives

Adding, Removing, and Replacing Tape Drives
The tape drive always resides in a universal drive sled (UDS), and
together they are effectively one unit. If you order a new or replacement
tape drive, it will already be installed in a sled.
Note:

Adding a Tape Drive

12

If you are installing multiple tape drives with the library
powered on, follow the special instructions in the note in
Step 3 below.

These instructions explain how to add a tape drive to your library. You
can add a tape drive while the library is powered on.
Required tools: None

1 Save the library configuration (see Saving the Library Configuration
on page 489).
2 Detach the tape drive slot’s cover plate. Loosen the cover plate’s
thumbscrews and remove the plate.
Store the cover plate in a separate cabinet. If you later decide to
remove the tape drive, you will need to reinstall the cover plate.
3 Insert the tape drive into the drive slot. Using the guide rails on both
the tape drive and in the tape drive slot, slowly slide the tape drive
into the slot. The tape drive must be level to slide in smoothly.
Note:

Special Instructions for Installing Multiple Tape Drives:

If you are installing multiple tape drives with the library
powered on, do not push the drive in all the way yet.
Instead, push it in almost all the way, leaving it out
approximately 3 inches so that it does not connect with the
library’s backplane. Then partially insert all of the other
new tape drives in the same manner. When all the new
tape drives are partially inserted, push them all the way in
at the same time.

Scalar i500 User’s Guide

438

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Tape Drives

4 Tighten the tape drive’s thumbscrews to secure the tape drive to the
module.
The thumbscrews must be aligned with the module’s screw holes. If
they are not aligned, the tape drive was not inserted correctly.
5 Power on the library (if it is not powered on already).
6 If the green LED is solidly lit for three seconds and then blinks twice,
wait 10-15 minutes while the universal drive sled (UDS) firmware
upgrades.
There are two types of firmware related to the tape drive: firmware
for the tape drive itself, and firmware for the UDS that surrounds the
tape drive. The UDS firmware is part of the library firmware. The
library automatically upgrades the UDS firmware if the firmware on
the newly inserted UDS is different than the library’s current UDS
firmware. Firmware downloads may take about 15 minutes.
7 Connect the host interface cables to the tape drive.
8 Take the tape drive online.
a From the Operations menu, select Drive > Change Mode.
The Change Drive Mode screen appears.
b Locate the tape drive that you want to take online.
c In the New column, click Offline to change the button status to
Online.
9 Check the tape drive’s LEDs to make sure that the drive functions
correctly (see Tape Drive LEDs on page 505. If the blue or amber
LED stays on solid, reseat the tape drive.
10 Add the new tape drive to an appropriate partition. You cannot use
the tape drive until it is assigned to a partition.
11 If necessary, upgrade tape drive firmware by following the
instructions provided in Updating Library and Tape Drive Firmware
on page 278. The library can use the tape drive immediately after the
firmware is upgraded.
12 Due to the way the library logically addresses its tape drives
internally (see Understanding Logical Element Addressing on
page 35), adding a tape drive to the library may change the tape
drive ordering, and this can affect proper communication to a
controlling host. Because of this, you must refresh the configuration
of any backup application that manages the library to reflect the

Scalar i500 User’s Guide

439

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Tape Drives

adjusted tape drive positions and the presence of the new drive. In
addition, you may need to reboot the host server(s) or rescan the bus
to detect the changes.

Permanently Removing a
Tape Drive
12

These instructions explain how to remove a tape drive that you do not
intend to replace with another one. You may want to permanently
remove a tape drive from your library if you are decreasing the size of
your SAN or reducing the number of partitions in your library.
You can remove a tape drive while the library is powered on. Do not,
however, remove a tape drive that is currently in use.
Required tools: None

1 Prepare host applications for tape drive removal.
2 Save the library configuration.
3 If there is a tape cartridge in the target tape drive, use the Web client
to unload it.
4 Using the Web client, delete the partition that uses the target tape
drive. Then re-create the partition, if desired, using another tape
drive.
5 Disconnect the host interface cables from the tape drive that you
want to remove.
6 From the back of the library, loosen the tape drive’s thumbscrews.
7 Remove the tape drive by gripping the tape drive handle and pulling
the entire tape drive toward you.
8 Install a cover plate over the vacant tape drive slot.
If you cannot find a cover plate, contact Quantum Support to order
one. It is important that all vacant slots have a cover plate to keep
unwanted materials out of the library.
Warning:

Running the library without a cover plate can be
dangerous. Doing so also causes the library to run at a
reduced speed.

9 Due to the way the library logically addresses its tape drives
internally (see Understanding Logical Element Addressing on
page 35), permanently removing a tape drive from the library may
Scalar i500 User’s Guide

440

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Tape Drives

change the tape drive ordering, and this can affect proper
communication to a controlling host. Because of this, you must
refresh the configuration of any backup application that manages the
library to reflect the adjusted tape drive positions and the presence of
the new drive. In addition, you may need to reboot the host server(s)
or rescan the bus to detect the changes.

Removing and Replacing
a Tape Drive
12

These instructions explain how to remove a tape drive and replace it with
a new one. You may need to replace a tape drive if you are experiencing
problems with one that is currently in use.
You can remove a tape drive while the library is powered on. Do not,
however, remove a tape drive that is currently in use.
The new tape drive replaces the old tape drive in the partition. You do
not need to delete the old tape drive or add the new tape drive to the
partition, unless the replacement tape drive is of a different type
(generation, interface, or vendor) than the original. If the original tape
drive is in a partition, and the replacement tape drive is of a different
type, the library generates a RAS ticket will not activate the tape drive. If
this happens, you must either replace the tape drive with one of the same
type, or delete the old tape drive from the partition and then add the new
tape drive to the partition (see Modifying Partitions on page 73).
Required tools: None

1 Prepare host applications for tape drive removal.
2 Save the library configuration.
3 If there is a cartridge in the tape drive, use the Web client to unload it.
4 Using the Web client, take the tape drive offline. When the tape drive
is ready for removal, its blue LED will be solidly lit.
a From the Operations menu, select Drive > Change Mode.
The Change Drive Mode screen appears.
b Locate the tape drive that you want to take offline.
c In the New column, click Online to change the mode to Offline.
5 Disconnect the host interface cables from the tape drive that you
want to remove.
6 From the back of the library, loosen the tape drive’s thumbscrews.

Scalar i500 User’s Guide

441

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing Tape Drives

7 Remove the tape drive by gripping the tape drive handle and pulling
the entire tape drive toward you.
8 Add the new tape drive in the vacant slot. Using the guide rails on
both the tape drive and the tape drive slot, slowly slide the tape drive
into the slot. The tape drive must be level to slide in smoothly.
9 Tighten the tape drive’s thumbscrews to secure the tape drive to the
module.
The thumbscrews must be aligned with the module’s screw holes. If
they are not aligned, the tape drive was not inserted correctly.
10 Power on the library (if itis not powered on already) and wait for
initialization to complete.
11 If the green LED is solidly lit for three seconds and then blinks twice,
wait 10-15 minutes while the universal drive sled (UDS) firmware
upgrades.
There are two types of firmware related to the tape drive: firmware
for the tape drive itself, and firmware for the UDS that surrounds the
tape drive. The UDS firmware is part of the library firmware. The
library automatically upgrades the UDS firmware if the firmware on
the newly inserted UDS is different than the library’s current UDS
firmware. Firmware downloads may take about 15 minutes.
12 Connect the host interface cables to the tape drive.
13 Take the tape drive online.
a From the Operations menu, select Drive > Change Mode.
The Change Drive Mode screen appears.
b Locate the tape drive that you want to take online.
c In the New column, click Offline to change the mode to Online.
14 Check the tape drive’s LEDs to make sure that the drive functions
correctly (see Tape Drive LEDs on page 505. If the blue or amber
LED stays on solid, reseat the tape drive.
15 If necessary, upgrade tape drive firmware by following the
instructions provided in the Updating Library and Tape Drive
Firmware on page 278. The library can use the tape drive
immediately after the tape drive firmware is upgraded.
16 When swapping out a tape drive, if the Logical SN Addressing feature
is enabled, the library reports a logical tape drive serial number to the
host that remains with the slot, so a replacement tape drive in the
Scalar i500 User’s Guide

442

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

same slot reports the same logical serial number and the host
recognizes it immediately (see Tape Drive Logical SN Addressing on
page 127). If Logical SN Addressing is disabled, the library reports
the actual tape drive serial number to the host, so a swapped tape
drive will not be registered by the host unless you refresh the
configuration of any backup application that manages the library. In
addition, you may need to reboot the host server(s) or rescan the bus
to detect the changes.

Adding, Removing, and Replacing FC I/O Blades
This section describes adding, removing, and replacing FC I/O blades.
The FC I/O blades support connections to LTO-2, LTO-3, LTO-4, LTO-5
and LTO-6 FC drives.
Caution:

If you are adding a new FC I/O blade or completely
removing an FC I/O blade, be sure to read Working With
Control Paths on page 86. If you do not configure control
paths correctly, you will experience communication
problems with tape drives and media changer devices
(partitions).

Details about FC I/O blades include:
• You must be running 400-level code or above in order to use FC I/O
blades.
• Each expansion module can support up to two FC I/O blades.
• A maximum of four FC I/O blades can be present in any library
configuration.
• A maximum of four FC drives can be connected to one FC I/O blade.
• FC I/O blades cannot be installed in control modules. However, FC
tape drives in the control module can be connected to FC I/O blades
in an expansion module.

Scalar i500 User’s Guide

443

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

• Each FC I/O blade is accompanied by a fan blade that cools the FC
I/O blade. The fan blade is installed to the right of the FC I/O blade
in the expansion module. Each expansion module has four bays and
can accommodate two FC I/O blades and two fan blades. Figure 62
shows the FC I/O blade and fan blade installed in the expansion
module. For instructions on installing the fan blade, see Adding,
Removing, and Replacing the FC I/O Fan Blade on page 454.
• The recommended order of installing the FC I/O blade and fan blade
in any expansion module is starting from the bottom two bays and
moving up.

Scalar i500 User’s Guide

444

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

Figure 62 FC I/O Blade and
Fan Blade Bays in an
Expansion Module

Scalar i500 User’s Guide

1

FC I/O blade

2

Fan blade

3

Expansion module

445

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

Read This First:
Complete Installation
Steps
12

When installing an FC I/O blade, you must follow the installation steps
in this order or communication with the FC I/O blade and tape drives in
the library will not work properly.
Caution:

If you are adding a new FC I/O blade or completely
removing an FC I/O blade, be sure to read Working With
Control Paths on page 86. If you do not configure control
paths correctly, you will experience communication
problems with tape drives and media changer devices
(partitions).

You may perform the following steps with the library powered on.
1 Ensure you are running 400-level firmware or above.
2 Save the library configuration (see Saving the Library Configuration
on page 489).
3 Connect the Ethernet cable from the Library Control Blade to the
expansion module(s). For each FC I/O blade installed in an
expansion module, connect the expansion module containing the FC
I/O blade(s) to a port in the Ethernet hub on the LCB (see Figure 48
on page 310).
Caution:

If the Ethernet cable between the LCB and the expansion
module is not connected when power is applied to the
blade, the blade will hang in the “Booting” state.

• If the FC I/O blade is installed in the bottom bay of the expansion
module, connect one end of an Ethernet cable to the Ethernet port
labeled LOWER in the lower right corner of the expansion module.
Connect the other end of the cable to a port in the Ethernet hub on the
LCB.
• If the FC I/O blade is installed in the upper bay of the expansion
module, connect one end of an Ethernet cable to the Ethernet port
labeled UPPER in the lower right corner of the expansion module.
Connect the other end of the cable to a port in the Ethernet hub on the
LCB.
4 Remove the control path from tape drives that you plan to connect to
an FC I/O blade. You must not allow an FC tape drive to serve as
control path if it is connected to an FC I/O blade. If you do, the
Scalar i500 User’s Guide

446

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

control path will be filtered out by the I/O blade and will not be
visible to the host. If a Fibre Channel tape drive is currently serving
as the control path for a partition and you plan to connect that tape
drive to an FC I/O blade, you must remove the control path from that
tape drive. To remove the control path from a tape drive:
a Select Setup > Control Path from the operator panel or the Web
client.
b If you have more than one partition, select the appropriate
partition and click Next.
c Clear the control path selection on any FC tape drive that you
plan to connect to an FC I/O blade.
5 Add or replace the fan blade(s) following the instructions in Adding,
Removing, and Replacing the FC I/O Fan Blade on page 454. The fan
blade is required to prevent overheating of the FC I/O blade.
6 Add or replace the FC I/O blade(s) following the instructions in
Adding an FC I/O Blade on page 448 or Replacing an FC I/O Blade
on page 453. If you are installing two FC I/O blades in an expansion
module, install the lower one first.
7 Make sure cover plates are installed over any unused bays in the
expansion module.
8 Connect the library and tape drive cables to the FC I/O blade (see
Figure 48 on page 310). See also Recommended Library Cabling for
FC I/O Blades on page 313.
9 Configure/reconfigure library partitions if needed (from the Web
client, select Setup > Partitions).
10 Configure control paths if needed. The library assigns control paths
for new partitions when they are created. Ensure that each partition
has only one control path. Ensure that you do not select an FC tape
drive as the control path if it is connected to an FC I/O blade. See
Working With Control Paths on page 86 for more important
information about control paths. To modify the control path, select
Setup > Control Path from the operator panel or Web client.
11 Configure host mapping (optional). If you have more than one FC
I/O blade in the library, each FC I/O blade will present each
partition that does not have a tape drive as the control path as a target
device to the host. Thus the host may see the same partition multiple
times. To minimize confusion, you should configure host mapping so
that each host sees each device only once. For more information, see

Scalar i500 User’s Guide

447

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

the Host Mapping - Overview on page 116 and Configuring Host
Mapping on page 118. To configure host mapping:
a From the operator panel or Web client, select Setup > FC I/O
Blades > FC I/O Blade Control and enable host mapping.
b From the operator panel or Web client, select Setup > FC I/O
Blades > Host Mapping.
12 Configure host port failover on the FC I/O blade (optional). From the
Web client, select Setup > FC I/O Blades > Host Port Failover. To enable
host port failover, you must configure target ports 1 and 2 on the
FC I/O blade as point-to-point connections (Setup > FC I/O Blades >
Port Configuration). For more information, see Configuring FC Host
Port Failover on page 119.
13 Save the library configuration (see Saving the Library Configuration
on page 489).

Adding an FC I/O Blade12

These instructions explain how to add an FC I/O blade to your library.
You can add an FC I/O blade while the library is powered on.
Required tools: None

1 Access the back of the expansion module.
Note:

The recommended order of installing the FC I/O blade
and fan blade in an expansion module is starting from the
bottom bay and moving up.

2 Remove the cover plate from the appropriate bay.
3 Press up and out to open the latch hooks on each side of the FC I/O
blade.

Scalar i500 User’s Guide

448

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

1

FC I/O blade

2

LEDs

3

Latch hooks, open

4 Carefully align the FC I/O blade with the guide slots in the bay. The
status LEDs must be at the bottom.
Caution:

Forcing the blade into the bay can cause the pins to
bend.

5 Evenly apply pressure to both sides of the blade and slide it into the
expansion module until the latch hooks begin to move toward the
middle of the blade. Push the latch hooks toward the middle of the

Scalar i500 User’s Guide

449

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

blade and into the locked position. You will feel the blade pins
connect with the expansion module’s backplane as the blade locks
into place.
Note:

The LEDs for the FC I/O blade are on the bottom of the
blade when the blade is correctly installed in the expansion
module.

6 Remove the necessary number of the black rubber protective covers
from the ports on the FC I/O blades when you are ready to cable the
blade.

Scalar i500 User’s Guide

450

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

Scalar i500 User’s Guide

1

Latch hooks, locked

2

FC I/O blade

3

Cover plate on empty bay

4

FC I/O blade LEDs

451

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

7 Make sure cover plates are installed over any unused bays in the
expansion module.
Caution:

Bays that are not populated with blades must
contain a cover plate. If the cover plate is not
installed, FC I/O blade temperature errors will
occur.

8 Cable the library as described in Cabling Libraries With Fibre
Channel Tape Drives Connected to Fibre Channel I/O Blades on
page 308.
9 Save the library configuration (see Saving the Library Configuration
on page 489).

Removing an FC I/O
Blade

12

These instructions explain how to remove an FC I/O blade from your
library. You can remove an FC I/O blade while the library is powered on.
Note:

The library will generate a RAS ticket when you remove the
I/O blade. If you do not want the library to generate a RAS
ticket, you can power down the I/O blade before removing it.
See Controlling FC I/O Blade Power on page 263.

Required tools: None

1 Access the back of the expansion module containing the FC I/O
blade.
2 Tag and disconnect all FC cables from the FC I/O blade.
Caution:

Handle the FC cables with care. They will be damaged
if they are bent at more than a four inch arc.

3 Lift the latch hooks out of the locked position and push them up. You
will feel the FC I/O blade unplug from the expansion module’s
backplane.
4 Continue lifting on the latch hooks until the blade is totally
unplugged from the backplane.
5 Slide the FC I/O blade out of the expansion module.
Scalar i500 User’s Guide

452

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades

6 Make sure cover plates are installed over any unused bays in the
expansion module.
7 If you are permanently removing the FC I/O blade, you will need to
configure the library to stop monitoring the FC I/O blade (see
Permanently Removing FC I/O Blades on page 497).
8 Save the library configuration (see Saving the Library Configuration
on page 489).

Replacing an FC I/O
Blade

12

These instructions explain how to replace an FC I/O blade in your
library. You can remove and replace a FC I/O blade while the library is
powered on.
Note:

The library will generate a RAS ticket when you remove the
FC I/O blade. If you do not want the library to generate a RAS
ticket, you can power down the FC I/O blade before removing
it. See Controlling FC I/O Blade Power on page 263.

Required tools: None

1 Access the back of the expansion module.
2 If you have not already done so, remove the old FC I/O blade,
following the directions in Removing an FC I/O Blade on page 452.
3 Press up and out to open the latch hooks on each side of the
replacement FC I/O blade.
4 Carefully align the FC I/O blade with the guide slots in the bay. The
status LEDs must be at the bottom.
Caution:

Forcing the blade into the bay can cause the pins to
bend.

5 Evenly apply pressure to both sides of the blade and slide it into the
expansion module until the latch hooks begin to move towards the
middle of the blade. Push the latch hooks towards the middle of the
blade and into the locked position. You will feel the blade pins
connect with the expansion module’s backplane as the blade locks
into place.

Scalar i500 User’s Guide

453

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing the FC I/O Fan Blade

Note:

The LEDs for the FC I/O blade are on the bottom of the
blade when the blade is correctly installed in the expansion
module.

6 Remove and discard the necessary number of the black rubber
protective covers from the ports on the FC I/O blades.
7 Reconnect the FC cables to the appropriate FC ports on the FC I/O
blade.
Caution:

Fibre optical cables will be damaged if they are bent at
more than a four-inch arc.

8 Save the library configuration (see Saving the Library Configuration
on page 489).
Note:

After you replace the FC I/O blade, the library ensures
that the FC I/O blade is loaded with the proper firmware.
This firmware is based on the currently installed level of
library firmware. If the autoleveling process fails, the FC
I/O blade becomes inoperable and the library creates a
ticket to report the issue. For information about LED
behaviors on blades during autoleveling operations, see
Blade Status LEDs on page 500.

Adding, Removing, and Replacing the FC I/O Fan Blade
Each FC I/O blade is cooled by a fan blade. The fan blade is always
installed in the bay to the right of the FC I/O blade. Each expansion
module has four bays and can accommodate two FC I/O blades and two
fan blades.
The recommended order of installing the FC I/O blade and fan in the
expansion module is starting from the bottom two bays and moving up.

Scalar i500 User’s Guide

454

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing the FC I/O Fan Blade

Figure 62 on page 445 shows the FC I/O blade and I/O fan blade
installed side-by-side in the expansion module.

Adding an FC I/O Fan
Blade
12

These instructions explain how to add an FC I/O fan blade to your
library. You can add an FC I/O fan blade while the library is powered on.
Required tools: None

1 Access the back of the expansion module.
2 Remove the cover plate from blade bay to the right of the bay for the
FC I/O blade.
Note:

The recommended order of installing the FC I/O blade
and fan blade in an expansion module is starting from the
bottom two bays and moving up.

3 Press up and out to open the latch hooks on each side of the FC I/O
fan blade. The LED must be at the bottom of the blade.

Scalar i500 User’s Guide

455

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing the FC I/O Fan Blade

1

Fan blade

2

LED

3

Latch hooks, open

Caution:

Forcing the blade into the bay can cause the pins to
bend.

4 Evenly apply pressure to both sides of the fan blade and slide it into
the expansion module until the latch hooks begin to move towards
the middle of the blade. Push the latch hooks towards the middle of
the blade and into the locked position. You will feel the blade pins
connect with the expansion module’s backplane as the blade locks
into place.

Scalar i500 User’s Guide

456

Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing the FC I/O Fan Blade

Note:

The LED for the FC I/O fan blade is on the bottom of the
blade when the blade is correctly installed in the expansion
module.

5 Save the library configuration (see Saving the Library Configuration
on page 489).

Removing an FC I/O Fan
Blade
12

These instructions explain how to remove an FC I/O blade from your
library. You can remove an FC I/O fan blade while the library is powered
on.
Caution:

Do not permanently remove an FC I/O fan blade unless
you also permanently remove the FC I/O blade to which it
is associated.

Required tools: None

1 Access the back of the expansion module containing the FC I/O fan
blade.
2 Lift the latch hooks out of the locked position and push them up. You
will feel the FC I/O fan blade unplug from the expansion module’s
backplane.
3 Continue lifting on the latch hooks until the blade is totally
unplugged from the backplane.
4 Slide the FC I/O fan blade out of the expansion module.
5 If you are permanently removing the FC I/O fan blade, place a cover
on the empty bay.
6 Save the library configuration (see Saving the Library Configuration
on page 489).

Replacing an FC I/O Fan
Blade
12

Scalar i500 User’s Guide

These instructions explain how to replace an FC I/O fan blade in your
library. You can remove and replace an FC I/O fan blade while the
library is powered on.

457

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Required tools: None

1 Access the back of the expansion module.
2 If you have not already done so, remove the old I/O fan blade,
following the directions in Removing an FC I/O Fan Blade on
page 457.
3 Press up and out to open the latch hooks on each side of the
replacement I/O fan blade.
4 Carefully align the FC I/O fan blade with the guide slots in the bay.
The status LED must be at the bottom.
Caution:

Forcing the blade into the bay can cause the pins to
bend.

5 Evenly apply pressure to both ends of the FC I/O fan blade and slide
it into the expansion module until the latch hooks begin to move
towards the middle of the blade. As you push in on the blade, you
will feel the blade pins connect with the expansion module’s
backplane.
6 Push the latch hooks into the locked position.
7 Save the library configuration (see Saving the Library Configuration
on page 489).

Tape Drive Ethernet Connectivity and the Ethernet
Expansion Blade
LTO-5 and LTO-6 FC tape drives enable you to use tape drive Ethernet
connectivity for FIPS-certified key exchanges, tape drive log collection,
tape drive firmware updates, and tape drive firmware autoleveling via
Ethernet instead of via internal serial communication. This speeds up
operations and provides the security required for FIPS-certified key
exchanges. 5U libraries can access tape drive Ethernet connectivity
directly via the library control blade. For libraries greater than 5U,
Quantum provides the Ethernet Expansion blade, which facilitates direct

Scalar i500 User’s Guide

458

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Ethernet connectivity between HP LTO-5 and LTO-6 Fibre Channel tape
drives and the library’s internal Ethernet via the library control blade.
Details about tape drive Ethernet connectivity and the Ethernet
Expansion blade include:
• Library firmware must be at version 600G or later.
• HP LTO-5 FC or HP LTO-6 FC tape drive firmware must be at the
latest version qualified with the Scalar i500 library (see the Scalar i500
Release Notes for qualified firmware levels).
• An Encryption Key Management license must be installed on the
library sufficient to cover all the tape drives you intend to use for
Ethernet operations.
• A Storage Networking license must be installed on the library
sufficient to cover all the tape drives you intend to use for Ethernet
operations.
• 5U libraries do not support an Ethernet Expansion blade. For 5U
libraries, connect the HP LTO-5 FC or HP LTO-6 FC tape drive to one
of the internal Ethernet ports on the library control blade (see
Figure 63 on page 461).
• In libraries that are greater than 5U, it is recommended that all HP
LTO-5 FC or HP LTO-6 FC tape drives be connected to an Ethernet
Expansion blade. The Ethernet Expansion blade is provided as part of
your FIPS-compliant solution when you purchase 8 Gb Storage
Networking tape drives.
• The Ethernet Expansion blade is not in the data path and does not
affect tape drive control paths.
• Each Ethernet Expansion blade has six Ethernet ports to allow you to
attach up to six HP LTO-5 FC or HP LTO-6 FC tape drives. Do not
attach tape drives of any other type to the Ethernet Expansion blade.
• Do not connect the Ethernet Expansion blade to an external Ethernet
source. The Ethernet Expansion blade is for internal Ethernet
connectivity within the library.
• The Ethernet Expansion blade must be installed in the bottom left
vertical bay in an expansion module. The empty bay to the right of
the Ethernet Expansion blade must be covered by a cover plate.
• Libraries may contain both Ethernet Expansion blades and FC I/O
blades.

Scalar i500 User’s Guide

459

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

• You may not connect a tape drive to both an Ethernet Expansion
blade and an FC I/O blade.
• You are limited to a maximum of four blades per library (Ethernet
Expansion blades and FC I/O blades), in any combination.
• If the tape drive Ethernet connection or an Ethernet Expansion blade
fails, you will not be able to perform encryption operations on any
connected tape drives that have FIPS mode enabled. You will still be
able to collect tape drive logs and update tape drive firmware via
internal serial communication.
Caution:

Cabling a 5U Library for
Ethernet Connectivity 12

If the Ethernet Expansion blade or Ethernet connectivity
fails and the attached tape drives have FIPS mode
enabled, all encryption operations (encrypting,
decrypting, key requests) on the attached tape drives will
fail. These operations will NOT automatically continue
over internal serial communication. If this happens,
contact Quantum Support for a replacement Ethernet
Expansion blade as soon as possible.

In a 5U library:
1 Upgrade library firmware to version 600G or later.
2 Upgrade tape drive firmware on all HP LTO-5 FC or HP LTO-6 FC
tape drives that you plan to connect via Ethernet to the latest version
qualified with the Scalar i500 library (see the Scalar i500 Release Notes
for qualified firmware levels).
3 Shut down the library.
4 Connect the tape drives to one of the four internal Ethernet ports on
the library control blade (LCB) using Ethernet cables (see Figure 63).
Note:

This figure and subsequent figures show two cables, but
only one cable is used unless you are using data path
failover.

5 Power on the library.

Scalar i500 User’s Guide

460

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 63 Ethernet
Connectivity on 5U Libraries
Ethernet cable
to network

Power cords

Fibre
Channel
cables to
host

Internal
Ethernet
ports on
LCB

Service port
– do not use

Library control
blade (LCB)

Installing the Ethernet
Expansion Blade
12

Ethernet cables from
tape drives to LCB

The Ethernet Expansion blade must be installed in the bottom left vertical
bay in an expansion module. The empty bay to the right of the Ethernet
Expansion blade must be covered by a cover plate.
Equipment Required

12

• Ethernet Expansion blade
• Cover plate
• Ethernet cables (one for each tape drive that you will connect to the
Ethernet Expansion blade), plus an extra one per Ethernet Expansion
blade, to connect the LCB to the expansion module in which the
Ethernet Expansion blade is installed.

Scalar i500 User’s Guide

461

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

12

Tools Required
None

12

Instructions
1 Upgrade library firmware to version 600G or later.

2 Upgrade tape drive firmware on all HP LTO-5 FC or HP LTO-6 FC
tape drives that you plan to connect to the Ethernet Expansion blade
to the latest version qualified with the Scalar i500 library (see the
Scalar i500 Release Notes for qualified firmware levels).
3 Optional – Save the library configuration (see the Scalar i500 User’s
Guide for instructions).
4 Shut down the library.
5 For every expansion module that will contain an Ethernet Expansion
blade, connect a standard Ethernet cable from one of the four internal
Ethernet ports on the library control blade (LCB) to the Ethernet port
marked “LOWER” located on the bottom right of the expansion
module in which the Ethernet Expansion blade is installed. There are
two ports, marked “UPPER” and “LOWER.” Since the Ethernet
Expansion blade must be installed in the lower bay of the expansion
module, you must use the Ethernet port marked “LOWER.” The
“LOWER” port is on the right. See Figure 64.

Scalar i500 User’s Guide

462

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 64 Connecting the
Library Control Blade to the
Expansion Module Via Ethernet
Ethernet cable to
network

Internal Ethernet
ports on LCB

Ethernet cable to
expansion module

Fibre
Channel
cables to
host
Cover plates

“UPPER” port. Do not “LOWER” port connected via
use for Ethernet Ethernet cable to LCB
Expansion blades.

Scalar i500 User’s Guide

463

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

6 Prepare the library for Ethernet Expansion blade installation. The
Ethernet Expansion blade must be installed in the bottom left bay of
an expansion module.
•

In some cases, this may require removal or relocation of an FC
I/O blade and its accompanying fan blade.

•

Remove the cover plate covering the two bottom left slots. To
remove the cover plate, unscrew the two captive thumbscrews
securing the cover plate and pull outward on the plate. Save the
cover plate in case you need to use it later.

7 Remove the new Ethernet Expansion blade from the protective antistatic bag.
8 Press up and out to open the latch hooks on each side of the blade.
Hold the Ethernet Expansion blade upright with the latch hooks on
the left side, and the status LEDs at the bottom (see Figure 65).

Scalar i500 User’s Guide

464

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 65 Ethernet Expansion
Blade

Latch hooks,
open

Status LEDs

9 Carefully align the Ethernet Expansion blade with the guide slots in
the bay.
Caution:

Forcing the blade into the bay can cause the pins
to bend.

10 Evenly apply pressure to both sides of the blade and slide it into the
expansion module until the latch hooks begin to move toward the
middle of the blade. Push the latch hooks toward the middle of the
blade and into the locked position. You will feel the blade pins
connect with the expansion module’s backplane as the blade locks
into place.
Scalar i500 User’s Guide

465

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

11 Observe the status LEDs on the Ethernet Expansion blade. The blue
LED should blink once every 10 seconds, indicating the blade is
powered on. The green LED should blink once per second, indicating
the blade’s processor is working normally. The amber LED should be
off.
12 Install a cover plate over the empty bay to the right of the Ethernet
Expansion blade.
Caution:

Scalar i500 User’s Guide

If the cover plate next to an Ethernet Expansion
blade is not installed, Ethernet Expansion blade
temperature errors will occur.

466

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 66 Installing the
Ethernet Expansion Blade
Doublewide cover
plate

Ethernet
Expansion blade

Cover
plate

Latch
hooks,
closed

LEDs

13 Cable the Ethernet Expansion blade (see Cabling the Ethernet
Expansion Blade on page 468).
14 Power on the library.
15 Verify the Ethernet Expansion blade is in the “Ready” state using one
of these methods:
•

Scalar i500 User’s Guide

Check the LEDs on the Ethernet Expansion blade. The green LED
should blink once per second, the blue LED should blink once
every 10 seconds, and the amber LED should be off.

467

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

•

Use the library Web client:

a Select Tools > Diagnostics to enter library diagnostics.
b A message warns you that entering diagnostics will log out all
other users of the same or lower privilege level.
c Click OK to agree to log all other users out.
d The diagnostics menu bar displays.
e Select Drives > EE Blade Control.
f A message warns you that power cycling an Ethernet Expansion
blade may cause key exchange failures if FIPS is enabled.
g Click OK to proceed.
h The Diagnostics - Ethernet Expansion Blade Control screen
displays (see Figure 68 on page 473).
i Check the Status column for the Ethernet Expansion blade to be
sure it says “Ready.”
16 Save the library configuration (see the library user’s guide for
instructions).

Cabling the Ethernet
Expansion Blade

12

Cable the library and Ethernet Expansion blade as follows (see Figure 67
on page 470).
• In a 14U and higher library, it is recommended that you do not
connect HP LTO-5 FC tape drives to the library control blade (LCB).
Instead, you should connect the tape drives to an Ethernet Expansion
blade using normal Ethernet cables.
• The Ethernet Expansion blade must be installed in the lower left slot
of the expansion module. A cover plate must cover the slot next to the
Ethernet Expansion blade. See Figure 67
• For every expansion module that contains an Ethernet Expansion
blade, make sure a standard Ethernet cable is connected from one of
the four internal Ethernet ports on the library control blade (LCB) to
the Ethernet port marked “LOWER” located on the bottom right of
the expansion module in which the Ethernet Expansion blade is
installed. There are two ports, marked “UPPER” and “LOWER.”
Since the Ethernet Expansion blade must be installed in the lower bay
of the expansion module, you must use the port marked “LOWER.”
The “LOWER” port is on the right. See Figure 67. You must do this
BEFORE placing the Ethernet Expansion blade into the library as per

Scalar i500 User’s Guide

468

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

the instructions in Installing the Ethernet Expansion Blade on
page 461.
• Tape drives connected to an Ethernet Expansion blade must not be
connected to an FC I/O blade. Instead, connect them to a host or
switch.

Scalar i500 User’s Guide

469

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 67 Ethernet
Connectivity on 14U and Higher
Libraries
Ethernet cable to
network
Power
cables

Internal Ethernet
ports on LCB

Cover plate
Fibre
Channel
cables to
host

Ethernet
Expansion blade
with six Ethernet
ports, connected
to tape drives via
Ethernet cables

Power
cables

Cover plate

Scalar i500 User’s Guide

“UPPER” port. Do not use for “LOWER” port connected via
Ethernet Expansion blades. Ethernet cable to LCB

470

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Ethernet cable to
network
Power
cables
Internal Ethernet
ports on LCB

Cover plate
Fibre
Channel
cables to
host

Ethernet
Expansion blade
with six Ethernet
ports, connected
to tape drives via
Ethernet cables

Power
cables

Ethernet
Expansion blade
with six Ethernet
ports, connected
to tape drives via
Ethernet cables

Cover plate

Scalar i500 User’s Guide

“UPPER” port. Do not use for
Ethernet Expansion blades.

“LOWER” port connected via
Ethernet cable to LCB

471

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Permanently Removing
or Relocating an Ethernet
Expansion Blade
12

Library firmware monitors all Ethernet Expansion blades after they are
installed in the library. Once an Ethernet Expansion blade is installed, the
library expects the blade to be in the same installed location after every
power cycle.
If an Ethernet Expansion blade is permanently removed from the library
or relocated within the library, the library firmware must be configured
to stop monitoring the EE blade. If this is not done and the library
continues to monitor a removed EE blade, RAS tickets could be
generated.
Note:

You do not need to configure the library to stop monitoring
an Ethernet Expansion blade if you are replacing a failed
Ethernet Expansion blade with a new Ethernet Expansion
blade in the same location (see Replacing an Ethernet
Expansion Blade in the Same Location on page 474).

1 If you are permanently removing the Ethernet Expansion blade,
disable FIPS mode on all Ethernet Expansion blade-connected tape
drives FIRST before you remove the Ethernet Expansion blade. To
disable FIPS mode, the tape drives must be Ethernet connected to
allow the tape drives to reconfigure. See Enabling and Disabling FIPS
Mode on HP LTO-5 and LTO-6 Tape Drives on page 201.
2 Remove the Ethernet Expansion blade from the library’s
configuration as follows:
a On the library web client, select Tools > Diagnostics to enter
library diagnostics.
A message warns you that entering diagnostics will log out all
other users of the same or lower privilege level.
b Click OK to agree to log all other users out.
The diagnostics menu bar displays.
c Select Drives > EE Blade Control.
The Diagnostics - Ethernet Expansion Blade Control screen
displays (see Figure 68).

Scalar i500 User’s Guide

472

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 68 Ethernet 27

Ethernet Expansion Blade Control

d Click the Remove button corresponding to the Ethernet
Expansion blade you want to remove.
Note:

Removing an Ethernet Expansion blade may cause
key exchange failures if FIPS is enabled. A message
warns you about the possible failures and asks you to
confirm that you want to proceed.

3 Click OK to proceed or Cancel to cancel the operation without
removing the Ethernet Expansion blade.
4 Disconnect the Ethernet cables from the Ethernet Expansion blade.
5 Lift the latch hooks out of the lock position and push them up (see
Figure 65 on page 465). You will feel the blade unplug from the
library’s backplane.
6 Continue lifting on the latch hooks until the Ethernet Expansion
blade is totally unplugged from the backplane.
7 Slide the Ethernet Expansion blade out of the bay.
8 Remove the cover plate from the bay to the right of the Ethernet
Expansion blade. Install the original double-wide cover plate over
both bays. This is required for cooling and dust reduction. If you
need a cover plate, contact Quantum.
9 Save the library configuration (see the library user’s guide for
instructions).

Scalar i500 User’s Guide

473

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Replacing an Ethernet
Expansion Blade in the
Same Location
12

If you are replacing an Ethernet Expansion blade in the same location,
you do not need to perform a “remove” operation via the web client as
you would if you were permanently removing or relocating the Ethernet
Expansion blade.
1 Disconnect the Ethernet cables from the Ethernet Expansion blade.
2 Lift the latch hooks out of the lock position and push them up (see
Figure 65 on page 465). You will feel the blade unplug from the
library’s backplane.
3 Continue lifting on the latch hooks until the Ethernet Expansion
blade is totally unplugged from the library’s backplane.
4 Slide the Ethernet Expansion blade out of the bay.
5 Install the new Ethernet Expansion blade (see Installing the Ethernet
Expansion Blade on page 461).
6 Save the library configuration (see the library user’s guide for
instructions).

Power Cycling the
Ethernet Expansion
Blade

12

Administrators can power cycle individual Ethernet Expansion blades in
the library. You might want to power cycle an individual Ethernet
Expansion blade when troubleshooting, such as when resolving a
Reliability, Availability, and Serviceability (RAS) ticket. You can only
power cycle the Ethernet Expansion blade from the Web client.
To power cycle an Ethernet Expansion blade:
1 On the Web client, select Tools > Diagnostics to enter library
diagnostics.
A message warns you that entering diagnostics will log out all other
users of the same or lower privilege level.
2 Click OK to agree to log all other users out.
The diagnostics menu bar displays.
3 Select Drives > EE Blade Control.
4 Click OK to proceed.
The Diagnostics - Ethernet Expansion Blade Control screen displays
(see Figure 68 on page 473).

Scalar i500 User’s Guide

474

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

5 Click the Cycle button corresponding to the Ethernet Expansion
blade you want to power cycle.
It takes approximately 1 minute to power cycle an Ethernet
Expansion blade. The status displays as “Booting” during the power
cycle.

Viewing Ethernet
Connectivity

12

There are two places on the library Web client which tell you whether
tape drives are connected via Ethernet (either via an Ethernet Expansion
blade or connected directly to the library control blade). These two places
are:
• Tools > Drive Operations > Update tape drive firmware using a
firmware image file
• Tools > Drive Operations > Retrieve Tape Drive Log
The tape drive table in each of these screens has a column called Ethernet
Connected. If the tape drive is connected via Ethernet, the tape drive IP
address will be listed in the column. If the tape drive is Ethernet capable
but not connected, the column displays “No.” If the tape drive is not
Ethernet capable, the column displays “N/A.”
You can also view the location coordinates and Ethernet Expansion blade
status in the library System Information Report:
• Reports > System Information

Ethernet Expansion
Blade Status LEDs

Scalar i500 User’s Guide

12

The status LEDs for the Ethernet Expansion blade are located at the
bottom of the Ethernet Expansion blade below ETH 6 (see Figure 69 on
page 476).

475

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Figure 69 Ethernet Expansion
Blade LEDs

Port LED status

Ethernet Expansion blade
status LEDs
- Left = Blue
- Middle = Amber
- Right = Green

Scalar i500 User’s Guide

476

Chapter 12 Installing, Removing, and Replacing
Tape Drive Ethernet Connectivity and the Ethernet Expansion Blade

Table 11 Ethernet Expansion
Blade Status LED Descriptions

LED Color

Represents

Blade Status

Green

Processor
status

• Solid OFF — Blade’s main processor is not operating (or blade is
booting).
• Solid ON — Blade’s main processor is not operating.
• Blinks once per second (1 Hz) — Normal.

Amber

Health status

• Solid OFF — Normal.
• Solid ON — Failure or blade is autoleveling.
In conjunction with the blue LED blinking once very 10 seconds,
this is a normal condition. Autoleveling takes about three minutes
per blade, and blades autolevel in series. Never remove a blade
when the amber LED is solid ON unless it has been on continuously
for at least 10 minutes.

Blue

Power
control
status

• Solid OFF — Blade is not receiving power.
• Solid ON — Blade is not operational.
• Blinks once every second (1 Hz) — Powered off. Ready to remove.
• Blinks once per 10 seconds (flash) — Normal. Blade is powered on.

Table 2 Explanation of Ethernet Expansion blade Ethernet Port LED States

LED Color

Blade Status

Green

• Solid ON — Link is up; data can be sent or received through the Ethernet port.
• Solid OFF — Link is down; data cannot be sent or received through the Ethernet
port.

Amber

• Flashes at irregular intervals — Data activity is occurring through the Ethernet port.
• Solid OFF — No data activity is occurring through the Ethernet port.

Scalar i500 User’s Guide

477

Chapter 12 Installing, Removing, and Replacing
Preparing the Library for Moving or Shipping

Preparing the Library for Moving or Shipping
Before you move or ship your library, follow these steps:
Caution:

When moving the library: Manufacturer-supplied

packaging, whether original or purchased, is required for
complete or partial de-installations. You must install the
orange robot restraint assembly to protect the robot
against damage. Use the original shipping carton and
packaging materials to further protect your library
equipment during transport.Not using the required
packaging will potentially void the support contract. Any
damage to equipment will require re-certification, or for
Quantum to repair any damage to the equipment, or both.
Quantum offers de-installation services. Please contact
your Quantum Authorized Reseller or local Quantum
Representative for further details.

Caution:

When shipping the library: Use the shipping carton,

packaging materials, and the orange robot restraint
assembly that originally came with the library. This will
help protect your library against damage.

1 Save the library configuration (see Saving the Library Configuration
on page 489).
2 Shut down the library using the local operator panel (Operations >
System Shutdown). This lowers the robot to the “shipping” position
on the floor of the library.
3 Follow instructions on the operator panel screen.
4 Turn off library power by pressing the power button on the front
panel.
5 Turn off the power to each power supply on the back of the library.
6 Install the orange robot restraint assembly that secures the robot to
the floor of the library. The robot restraint assembly was part of the
packaging that originally came with the library.
7 Remove all cords and cables from the rear of the library.
Scalar i500 User’s Guide

478

Chapter 12 Installing, Removing, and Replacing
Preparing the Library for Moving or Shipping

8 Remove all tape cartridges from the library.
9 Remove the tape drives from the library to decrease the weight when
lifting the modules.
Warning:

Without tape drives, tape cartridges, or power
supplies, a control module weighs approximately 60
lbs (27.2 kg). An expansion module, without tape
drives, tape cartridges, or power supplies, exceeds 65
lbs (29.5 kg).
To avoid serious injury, at least two people are
required to safely lift the modules.

10 If rack-mounted, remove one module at a time from the rack. Retain
the rack-mounting hardware and shelves for use in the new location.
11 Place the module in the bottom of the shipping carton.
12 Reinstall the tape drives in the module.
13 Complete the packing. For further details, see the Unpacking
Instructions.

Scalar i500 User’s Guide

479

Chapter 13

13

Troubleshooting

The Scalar i500 library includes advanced system monitoring and alerting
mechanisms that inform you of library status and issues. It provides you
with status information about various library subsystems and
components. It also notifies you of issues it detects and guides you
through diagnosing and correcting issues before problems interfere with
backups.
This chapter covers:
• About RAS Tickets
• Capturing Snapshots of Library Information
• Saving and E-mailing the Library Configuration Record
• Saving and Restoring the Library Configuration
• Troubleshooting “Library Not Ready” Messages
• Duplicate Devices Discovered
• Duplicate Media Changer Devices Discovered
• Identifying Tape Drives
• Retrieving Tape Drive Logs
• Retrieving Tape Drive Sled Logs
• Identifying FC I/O Blades
• Permanently Removing FC I/O Blades
• Resetting FC I/O Blade Ports

Scalar i500 User’s Guide

480

Chapter 13 Troubleshooting
Quantum’s Knowledge Base

• Viewing and E-Mailing the Command History Logs
• Interpreting LEDs
• Using the Installation Verification Test
• Configuring the Internal Network
• Library Diagnostics
•

Drive DiagnosticsDrive TestsMedia TestsEthernet Expansion
Blade Control

• Robotics Diagnostics

Quantum’s Knowledge Base
Quantum keeps a dynamic listing of frequently asked questions,
troubleshooting tips, and service bulletins for all of its products. To access
the knowledge base, go to the Quantum Support Web site and click on
Knowledge Base:
http://www.quantum.com/ServiceandSupport/Index.aspx.

About RAS Tickets
The Scalar i500 library uses advanced problem detection, reporting, and
notification technology to alert you of problems as soon as they occur.
The library performs numerous self-tests to monitor the library’s
temperature, voltage and currents, and standard library operations. It
performs these self-tests each time the library is powered on and during
normal operation when the library is idle.
If the self-test detects a problem, the library generates a Reliability,
Availability, and Serviceability (RAS) ticket that identifies the component
that is likely causing the problem. The library’s light emitting diodes
(LEDs) may also turn on or off and flash to indicate an abnormal state. If

Scalar i500 User’s Guide

481

Chapter 13 Troubleshooting
About RAS Tickets

the problem is not severe, the library continues to provide full
functionality to all unaffected partitions.
RAS tickets have three priority levels:
• Low— Informational message. Indicates that an abnormal condition
exists within the library that warrants investigation and correction
but the nature of the condition may have little or no effect on
operations.
• High — Warning message. Indicates that a condition exists within the
library that impacts system performance, redundancy, or a specific
host application. Typical library operations can continue without
immediate corrective action, although an application may have failed
and may need to be restarted. A user should investigate the condition
and correct the problem soon.
• Urgent — Critical issue. Indicates that a failure has occurred or a
serious condition exists within the library that requires immediate
corrective action. In most cases, a hardware component is no longer
functioning at an acceptable level or has failed. Typical library
operations required for backup or restore operations are either not
possible or are highly unreliable.
When possible, the RAS ticket provides instructions for resolving
problems. You can view RAS tickets on both the operator panel and the
Web client. Access the library’s online Help system if you have questions
about the instructions provided. To access the online Help system, click
the Help icon at the top right of the Web client or operator panel user
interface.
You can frequently resolve a simple problem yourself, but if the problem
is complex or involves a field replaceable unit (FRU), you will be directed
to contact service. Only qualified service technicians can service FRUs.

Caution:

Viewing RAS Tickets

Scalar i500 User’s Guide

13

Do not work with RAS tickets while the library is
performing an inventory. Doing so may result in inventory
discrepancies, such as missing tape cartridges.

Selecting All RAS Tickets from the Tools menu on both the operator panel
and the Web client opens the All RAS Tickets screen, which lists RAS
tickets in order of last occurrence of each event, beginning with the most
recent.

482

Chapter 13 Troubleshooting
About RAS Tickets

Note:

Last Occurrence indicates the last time a ticket event occurred.
This information updates any time the event recurs. Last
Occurrence does NOT update if you open, close, or resolve the

RAS Ticket.

Included in the list is a brief description of the error condition captured
by the RAS ticket. The All RAS Tickets screen allows you to view RAS
ticket details and navigate to ticket resolution information. If you want to
request technical support, the Ticket Details and Ticket Resolve windows
provide a link to the online service request Website.
The initial status of all RAS tickets is Unopened. Once the administrator
selects the Resolve button on the All RAS Tickets screen for a ticket, its
status changes to Opened. When the user closes the ticket, its status
changes to Closed. You can view Opened and Unopened tickets on both
the operator panel and the Web client, but you can view Closed tickets
only on the Web client.
Caution:

Be careful when pressing the Close All Tickets button. This
closes all RAS tickets even if they are not resolved. It is
recommended that each RAS ticket be viewed, analyzed,
and closed individually.

The paths to open the appropriate screens are:
• From the Web client, select Tools > All RAS Tickets.
• From the operator panel, select Tools > All RAS Tickets.

Resolving and Closing
RAS Tickets
13

Administrators can resolve some RAS tickets. Others must be resolved by
Service personnel. Only one person at a time can resolve a ticket. Multiple
users can, however, view ticket details simultaneously. If your Web client
session goes down while resolving a RAS ticket, you must wait 3 minutes
before you can continue resolving the RAS ticket from either the Web
client or the operator panel.
1 Log in to the Web client.
2 From the Tools menu, select All RAS Tickets.
The Tools - All RAS Tickets screen appears.

Scalar i500 User’s Guide

483

Chapter 13 Troubleshooting
About RAS Tickets

3 Identify the RAS ticket you want to resolve.

Note:

You can use the Go to RAS Ticket text box at the bottom of
the screen to locate a specific RAS ticket number. In
addition, if there is more than one page of RAS tickets, use
the Page 1 of x arrows to view the additional tickets.

4 Click Resolve.
The Ticket Resolution window appears. This window contains
information on how to resolve the ticket.
5 Review the description.
6 Do one of the following:
a To close the ticket now, click Close.
The Tools - All RAS Tickets window displays, with the RAS ticket
no longer in the list. The task is complete and the RAS ticket is
resolved.
b

To leave the ticket open for future troubleshooting, click Exit.
Then you can perform the diagnostic steps you need to resolve a
related RAS ticket.

If you want to request technical support, the ticket Resolve window
provides a link to the online service request Website.
Note:

To display all closed tickets, select the Include Closed Tickets
check box at the bottom of the screen. The Tools - All RAS
Tickets screen refreshes, with the Resolve button unavailable
for all closed RAS tickets.

Caution:

Be careful when pressing the Close All Tickets button. This
closes all RAS tickets even if they are not resolved. It is
recommended that each RAS ticket be viewed, analyzed,
and closed individually.

The path to open the appropriate screen is:
• From the Web client, select Tools > All RAS Tickets.

Scalar i500 User’s Guide

484

Chapter 13 Troubleshooting
Capturing Snapshots of Library Information

Closing RAS Tickets
Automatically

13

The library will close all currently open RAS tickets when you reboot the
library. If any errors occur during the reboot, the library issues new
tickets.
Automatic ticket closure will only occur when you intentionally initiate a
reboot, by either restarting the library, shutting down the library, or
upgrading library firmware. Automatic ticket closure will not occur if the
library shuts down unexpectedly or if the power cord is unplugged.
You can always view closed tickets on the Web client by selecting Tools >
All RAS Tickets and clicking the Include Closed Tickets check box. Tickets
that were auto-closed are designated as “Canceled.”
Automatic ticket closure is enabled by default. You can enable or disable
this feature from the operator panel.
The path to open the appropriate screen is:
• From the operator panel, select Tools > System Settings.

Capturing Snapshots of Library Information
Technical support personnel may ask you to perform the Capture
Snapshot operation, so they can better diagnose issues. The Capture
Snapshot operation captures detailed information about the entire library
in a single ASCII file that can be e-mailed to technical support personnel.
The logged information consists of configuration data, status
information, and trace logs for library components. Trace logs collect
problem data and provide support personnel with vital library
information for troubleshooting and solving problems.
You can e-mail the snapshot file from both the operator panel and the
Web client. On the Web client, you can also download the Capture
Snapshot file to a computer. You cannot download Capture Snapshot
files from the library’s operator panel, and you cannot print Capture
Snapshot files from either the Web client or the operator panel.
Depending on the library configuration and your connection speed,
saving the Capture Snapshot file takes approximately 30 minutes. The
resulting file size can be large. Your firewall file-size limitations could
prohibit you from e-mailing the file.
Scalar i500 User’s Guide

485

Chapter 13 Troubleshooting
Saving and E-mailing the Library Configuration Record

On the Web client, ensure that the library e-mail account is appropriately
configured before you attempt to e-mail the snapshot from the library. If
the library e-mail account address is not configured, an error appears. For
information on setting up the e-mail account, see Configuring the Library
E-mail Account on page 92.
You can configure the library to automatically attach a library snapshot
to certain RAS ticket e-mail notifications (see Configuring the Library Email Account on page 92). If the library is in the process of capturing an
automatic snapshot, you will not be able to manually capture a snapshot
via the Web client until the automatic snapshot is complete. If this
happens, an error message will display. Wait about 10 minutes and try
again.
The paths to open the appropriate screens are as follows:
• From the Web client, select Tools > Capture Snapshot.
• From the operator panel, select Tools > Capture Snapshot.

Saving and E-mailing the Library Configuration Record
The library configuration record is a text file that contains details about
the library’s configuration. The configuration record can be saved or
e-mailed to a specified e-mail address.Information in the library. The
configuration record includes:
• Product information—vendor, model, product ID, product version
(library firmware version), and serial number.
• Capacity on Demand (COD) license information—licensed slots and
expiration date.
• Module information—vendor, module type, module serial number,
and module location coordinates.
• Tape drive information:
•

Scalar i500 User’s Guide

SCSI tape drives—partition name, number of tape drives in
partition, drive location, SCSI element address, online status,
active status, ready state, vendor, model, serial number, tape
drive firmware version, drive type, logical serial number,
interface type, SCSI ID, and LUN.
486

Chapter 13 Troubleshooting
Saving and E-mailing the Library Configuration Record

•

Fibre Channel (FC) tape drives—partition name, number of tape
drives in partition, drive location, SCSI element address, online
status, active status, ready state, vendor, model, serial number,
tape drive firmware version, drive type, logical serial number,
interface type, World Wide Node Name (WWNN) loop ID,
topology, speed, and actual speed.
Note:

E-mailing the
Configuration Record 13

If the FC tape drive is attached to an FC I/O blade, the
WWNN indicates the WWNN of the I/O blade, not
the tape drive.

•

Serial Attached SCSI (SAS) tape drives—partition name, number
of tape drives in partition, drive location, SCSI element address,
interface type, drive type, ready state, online status, barcode,
media type, element address, vendor, model, physical serial
number, logical serial number, SCSI ID, firmware level, control
path status.

•

I/O blade information—blade number, blade ID, location
coordinates, serial number, WWNN, firmware version, and
control LUN.

•

Partition information—number of partitions, number of cleaning
slots, number of unassigned slots, number of import/export
(I/E) slots, I/E manual assignment setting, partition name,
number of slots, number of tape drives, and number of
cartridges.

Administrators can use the Tools - E-mail Configuration Record screen on
the Web client to e-mail the library configuration record.
Do not enter more than one e-mail address in the E-mail Address text box
on the Tools - E-mail Configuration Record screen. If you need to send the
configuration record to multiple e-mail addresses, repeat the procedure
for each e-mail address.
Before you can e-mail the configuration record, the library e-mail account
must be configured. For information on setting up the e-mail account, see
Configuring the Library E-mail Account on page 92.

Scalar i500 User’s Guide

487

Chapter 13 Troubleshooting
Saving and Restoring the Library Configuration

You cannot e-mail the library configuration record from the operator
panel. The path to open the appropriate screen is as follows:
• From the Web client, select Tools > E-mail Configuration Record.

Saving the Configuration
Record
13

Administrators can use the Tools - Save Configuration Record screen on
the Web client to e-mail the library configuration record.
You cannot save the library configuration record from the operator panel.
The path to open the appropriate screen is as follows:
• From the Web client, select Tools > Save Configuration Record.

Saving and Restoring the Library Configuration
The library has many configurable items, such as tape drive IDs,
partitions, user accounts, Import/Export (I/E) stations, and cleaning
slots. In the event of a hardware failure or firmware upgrade, the save
and restore operations can be used to restore the library’s firmware and
configurable items to a previous state.

Scalar i500 User’s Guide

Note:

You cannot restore a saved configuration after removing or
replacing a control module or expansion module. After
removing and/or replacing the module, save the library
configuration for future use.

Note:

The Saving and Restoring operations should not be performed
concurrently by multiple administrators logged in from
different locations. You can access the screens, but you cannot
apply changes while another administrator is performing the
same operation.

488

Chapter 13 Troubleshooting
Saving and Restoring the Library Configuration

Saving the Library
Configuration

13

Caution:

Always save the library configuration after modifying a
configurable item and before upgrading firmware. This
allows you to restore the most current settings if necessary.

This operation saves your current library configuration and library
firmware. Save your library configuration when it is in a known working
state. In the event of a hardware failure, the saved configuration can be
used to restore the configuration after hardware repairs are made. Before
initiating a firmware upgrade, you should save the library configuration.
You then have the option to restore the configuration after either a
successful or an unsuccessful upgrade.
The Save/Restore Configuration operation is available only on the Web
client. The path to open the appropriate screen is:
• From the Web client, select Tools > Save/Restore Configuration.

Restoring the Library
Configuration and Library
Firmware
13

You can restore the library’s configurable items to a previous state using
a saved configuration file. If you updated the library firmware since last
saving the configuration, the library automatically restores the library
firmware to the version that was saved with the configuration.
You can also downgrade library firmware to an earlier version using the
Tools > Update Library Firmware command. Note that you will lose all
your current library configuration information except for network
settings, date and time, and license keys. You can restore the other
configurable items using a configuration file that was saved when the
earlier version of library firmware was installed on the library, or you can
reconfigure your library’s settings.
Note:

Scalar i500 User’s Guide

The configuration file must be at the same or an earlier version
of firmware than that which is currently installed on the
library. You cannot restore a configuration file created with a
later version of firmware.

489

Chapter 13 Troubleshooting
Troubleshooting “Library Not Ready” Messages

Note:

If your library is running firmware version 600G or later, you
can only restore a saved configuration that was created with
firmware version 410G or later. If you need to restore a
configuration created with firmware that is earlier than 410G,
contact Quantum Support for assistance.

The Configuration operation is available only on the Web client. The path
to open the appropriate screen is:
• From the Web client, select Tools > Save/Restore Configuration.

Troubleshooting “Library Not Ready” Messages
The operator panel and Web client each include a header that contains
the company logo, product name, and the three main navigation buttons
Home, Help, and Logout. In addition, a message in the header alerts you
when the library is not ready. (No message displays in the header when
the library is in a ready state.)
On the operator panel, LIBRARY NOT READY flashes at regular intervals
whenever the library robotics are not yet ready to perform library
functions. To view more information about the library’s condition, select
Tools > About Library. The State field on the About Library screen will
display Not ready, followed, when applicable, by a brief explanation. For
example, if the library door is open, the State field will display: Not ready,
door is open.
The header in the Web client also alerts you when the library is not ready.
For instance, if the library door is open, the header will display the
following message: Library’s door is open.
“Library Not Ready” messages appear in the header in the operator panel
and the Web client under the following circumstances:
• The robot is in the process of calibrating. When the robot has finished
calibrating, the “Library Not Ready” message no longer appears.
• The robot cannot calibrate. For example, a fiducial label is missing,
preventing the robot from calibrating.

Scalar i500 User’s Guide

490

Chapter 13 Troubleshooting
Duplicate Devices Discovered

• The robot requires manual intervention. For example, the picker
contains a tape cartridge that it cannot unload.
• The library door is open. The robot will not operate if the door is
open.
• If none of the above situations apply, but the library is still not ready
to operate, the header will display a “Library Not Ready” message
without additional detail. The library generates a RAS ticket
whenever the library enters a “not ready” state. The RAS ticket may
provide information that can help you troubleshoot the problem. See
Viewing RAS Tickets on page 482 for more information.
“Library Not Ready” messages continue to display in the header as well
as on the About Library screen until the issue has been resolved, and the
robot has completed its calibration.
Note:

You may not see the “Library Not Ready” message in the Web
client until the browser refreshes. Similarly, even if the
problem has been resolved, the “Library Not Ready” message
will not disappear from the Web client until the browser
refreshes.

Duplicate Devices Discovered
If both target ports (ports 1 and 2) on an FC I/O blade are connected to
the same host, or if more than one host is connected to a target port, you
may see duplicates of all the devices connected to the initiator ports
(ports 3 – 6) of that FC I/O blade. To prevent this from happening, you
can do either (or both) of the following:
• If only one host is connected to a target port, you can use channel
zoning to tell the target port which devices to see (see Configuring FC
I/O Blade Channel Zoning on page 111).
• If more than one host is connected to a target port, you can use host
mapping to tell each host which devices to see (see Configuring Host
Mapping on page 118).

Scalar i500 User’s Guide

491

Chapter 13 Troubleshooting
Duplicate Media Changer Devices Discovered

Duplicate Media Changer Devices Discovered
You may see one or more media changer devices (partitions) being
discovered multiple times. For information on why this happens, see FC
I/O Blade Internal Virtual Port for Media Changers on page 111.
To prevent this, do the following:
• Ensure that host mapping is enabled (see Enabling/Disabling FC
Host Mapping on page 113).
• Assign each media changer a unique LUN and map each one to the
appropriate host (see Configuring Host Mapping on page 118).

Identifying Tape Drives
You can use the operator panel and the Web client user interfaces to view
information about all tape drives installed in the library. In addition, you
can identify tape drives, including the control path tape drive, in selected
partitions. The Web client also allows you to identify tape drives that are
not assigned to specific partitions. On the Web client, you can only
identify tape drives that are in a ready state.
The operator panel Drive Information screen lists the following
information for each tape drive:
• Control path tape drive status — yes/no
• Vendor
• Model
• Type
• Serial number
• Tape drive firmware version
• Sled boot version
• Sled application version

Scalar i500 User’s Guide

492

Chapter 13 Troubleshooting
Identifying Tape Drives

• Mode status — online/offline, ready/not ready
• Loaded status — unloaded/loaded
• SCSI ID for SCSI tape drives
• World Wide Node Name (WWNN) for Fibre Channel (FC) tape
drives
• SAS address for SAS tape drives
The Web client Identify Drives screen lists the following information for
each tape drive:
• Location coordinates
• Mode status — online/offline
• State — ready/not ready
• Drive type
• Protocol
• Control path tape drive status — yes/no
• Vendor
• Physical serial number (P-SN)
• Logical serial number (L-SN)
• Tape drive firmware version
Note:

Bold column headings in the table can be sorted. For example,
selecting the Location column heading will sort by location
coordinates.

On the operator panel Drive Information screen, you can identify the tape
drives assigned to the selected partition as well as the control path tape
drive for the partition by flashing the green light-emitting diodes (LEDs)
on the back of the tape drives.
• Use the Identify All button to flash the green LEDs on the back of the
tape drives assigned to the partition. The LEDs blink 10 times per
second for one minute.
• Use the Identify Ctrl Path button to flash the green LED on the back of
the control path tape drive for the partition. The control path tape
drive is used to connect each partition to the host application. Use

Scalar i500 User’s Guide

493

Chapter 13 Troubleshooting
Identifying Tape Drives

this button when you are cabling the library or troubleshooting the
library control paths of tape drives. The green LED blinks 10 times
per second for one minute.
On the Web client Identify Drives screen, you can identify the tape drives
assigned to a particular partition, all unassigned tape drives, and the
control path tape drive for each partition by flashing the green LEDs on
the back of tape drives that are in a ready state:
• Use the Identify All button to flash the LEDs on the back of the
selected tape drives. Only tape drives in a ready state will flash. If
you have selected a specific partition or have only one partition
configured, all the green LEDs on the tape drives within the partition
will blink. If you have selected Unassigned, all the green LEDs on the
unassigned tape drives will blink. If you have selected All, the green
LEDs on all tape drives installed in the library will blink.
• Click Identify Control Path to flash the green LEDs on the back of the
one or more control path tape drives. Only tape drives in a ready
state will flash. The control path tape drive is used to connect each
partition to the host application. Use this button when you are
cabling the library or troubleshooting the library control paths of tape
drives. If you have selected a partition, the green LED on the
partition’s control path tape drive will blink. If you have selected All,
the green LEDs on all the ready control path tape drives will blink.
Note:

There is no control path tape drive for a partition that uses
FC I/O blades to connect tape drives to a host application.

The paths to open the appropriate screens are as follows:
• From the Web client, select Tools > Identify Drives.
• From the operator panel, select Tools > Drive Info.

Scalar i500 User’s Guide

494

Chapter 13 Troubleshooting
Retrieving Tape Drive Logs

Retrieving Tape Drive Logs
Administrators can use the Web client to retrieve tape drive logs. Tape
drive log information can be used to help troubleshoot library and tape
drive issues. You can use the Retrieve Drive Log screen to select the
appropriate tape drive.
Note:

Bold column headings in the table can be sorted. For example,
selecting the Location column heading will sort by location
coordinates.

Details on retrieving tape drive log files include:
• Since the log retrieval process can take up to 30 minutes, the tape
drive and associated partition are automatically taken offline during
the operation and brought back online when the operation completes.
You will be asked to confirm that you want to take the tape drive and
partition offline.
Note:

If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see Taking a Partition
Online or Offline on page 76).

• Tape drive logs adhere to the following naming convention:
UDS_ID_SN.dmp, where ID identifies the tape drive coordinate
location within the library and SN identifies the tape drive serial
number.
• You can select the interface type (SCSI, SAS, or FC) of the tape drive
from which you want to retrieve logs.
For more detailed, step-by-step instructions, see your library’s online
Help. To access the online Help system, click the Help icon at the top right
of the Web client or operator panel user interface.
You cannot retrieve tape drive logs from the operator panel. The path to
open the appropriate screen is as follows:
• From the Web client, select Tools > Drive Operations.

Scalar i500 User’s Guide

495

Chapter 13 Troubleshooting
Retrieving Tape Drive Sled Logs

Retrieving Tape Drive Sled Logs
Administrators can retrieve tape drive sled logs. Tape drive sled log
information can be used to help troubleshoot library, tape drive sled, and
tape drive issues. You can use the Retrieve Drive Sled Log screen to select
the appropriate tape drive sled.
Note:

Bold column headings in the table can be sorted. For example,
selecting the Location column heading will sort by location
coordinates.

Details on retrieving tape drive sled log files include:
• Tape drive sled logs adhere to the following naming convention:
UDS_ID_SN.LOG, where ID identifies the tape drive sled coordinate
location within the library and SN identifies the tape drive sled serial
number.
• You can select the interface type (SCSI, SAS, or FC) of the tape drive
sled from which you want to retrieve logs.
• A Save dialog allows you to specify where you want to save the tape
drive sled log files file.
For detailed, step-by-step instructions, see your library's online Help. To
access the online Help system, click the Help icon at the top right of the
Web client or operator panel user interface.
You cannot retrieve tape drive sled logs from the operator panel. The
path to open the appropriate screen is as follows:
• From the Web client, select Tools > Drive Operations.

Identifying FC I/O Blades
Administrators can flash the green LED on a selected FC I/O blade to
identify the physical location of the I/O blade in the library. After
performing this blade operation, go to the back of the library and identify
Scalar i500 User’s Guide

496

Chapter 13 Troubleshooting
Permanently Removing FC I/O Blades

the I/O blade with the rapidly blinking LED at the bottom of the FC I/O
blade. The LED will blink for one minute.
The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > I/O Blades > Blade Control.
• From the operator panel, select Setup > I/O Blades > Blade Control >
Identify Blade.

Permanently Removing FC I/O Blades
Library firmware monitors all FC I/O blades after they are installed in
the library. Once an FC I/O blade is installed, the library expects the
blade to be in the same installed location after every power cycle.
If an FC I/O blade is relocated or is permanently removed from the
library, the library firmware must be configured to stop monitoring the
blade. Administrators can perform this operation by selecting the FC I/O
blade and performing the remove blade operation on the Setup - FC I/O
Blade Control screen. If this is not done and the library continues to
monitor a removed FC I/O blade, RAS tickets could be generated.
You do not need to configure the library to stop monitoring an FC I/O
blade if the failed blade is replaced with a new blade. For instructions on
how to remove and replace an FC I/O Blade, see Adding, Removing, and
Replacing FC I/O Blades on page 443.
Performing the remove blade operation will cause a temporary loss of
communication with connected hosts. The screen will display a warning
message about the communication loss and ask you to confirm that you
want to proceed.
Note:

Scalar i500 User’s Guide

Before permanently removing the FC I/O blade, verify the
location of the FC I/O blade. See Identifying FC I/O Blades on
page 496.

497

Chapter 13 Troubleshooting
Resetting FC I/O Blade Ports

Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > FC I/O Blades > FC I/O Blade
Control.
• From the operator panel, select Setup > FC I/O Blades > FC I/O Blade
Control > Remove Blade.

Resetting FC I/O Blade Ports
Administrators can reset individual ports on FC I/O blades. Resetting
these ports can help troubleshoot FC I/O blade issues. The Setup - Blade
Control screen allows you to perform the Reset Port operation on a
selected FC I/O blade port.
Resetting an FC I/O blade port will cause a temporary loss of
communication with connected hosts. The screen will display a warning
message about the communication loss and ask you to confirm that you
want to proceed.

Scalar i500 User’s Guide

Note:

This operation should not be performed concurrently by
multiple administrators logged in from different locations.
You can access the appropriate screens, but you cannot apply
changes while another administrator is performing the same
operation.

Note:

Before resetting FC I/O blade ports, verify the location of the
FC I/O blade. See Identifying FC I/O Blades on page 496.

498

Chapter 13 Troubleshooting
Viewing and E-Mailing the Command History Logs

The paths to open the appropriate screens are as follows:
• From the Web client, select Setup > FC I/O Blades > FC I/O Blade
Control.
• From the operator panel, select Setup > FC I/O Blades > FC I/O Blade
Control > Reset Port.

Viewing and E-Mailing the Command History Logs
When FC I/O blades are installed, administrators can use the Command
History Log screens to view the most recent command and response
activity that has occurred with externally addressable library devices,
controller LUNs, partitions, and tape drives. This information can help
you isolate the source of an issue, such as a library device or host
application.

You can select any configured FC I/O blade in the library and display a
list of associated library devices. For each device, you can view the
command history log. You can also choose to e-mail the command history
to a specific e-mail address. The log is sent as a text file attached to an email message.
Before you can e-mail the command history log, the library e-mail
account must be configured. For information on setting up the e-mail
account, see Configuring the Library E-mail Account on page 92 in
Configuring Your Library.
You cannot view command history logs from the Web client. The path to
open the appropriate screen is as follows:
• From the operator panel, select Tools > Command History Log.

Scalar i500 User’s Guide

499

Chapter 13 Troubleshooting
Interpreting LEDs

Interpreting LEDs
LEDs provide a visual indication about the status of certain library
components. LEDs can sometimes communicate that a problem exists
when RAS tickets cannot. For example, an LED can indicate a firmware
problem that prohibits the library from generating RAS tickets.
The following components of the library have LEDs:
• Library control blade (LCB)
• FC I/O blade
• FC I/O fan blade
• Ethernet Expansion blade
• Tape drives
• Power supplies
Some of these components may also include a fibre port link LED.

Blade Status LEDs

13

This section covers status LEDs for:
• Library control blade (LCB)
• FC I/O blade
• FC I/O fan blade
• Ethernet Expansion blade
Figure 70 shows the location of the blade LEDs. Use Table 12 to interpret
the current status of the LEDs.

Scalar i500 User’s Guide

500

Chapter 13 Troubleshooting
Interpreting LEDs

Figure 70 Location of Blade
LEDs
Library Control Blade

Fibre-channel I/O Blade and Fan Blade

Ethernet Expansion Blade

Library
Control
Blade
Status
LEDs

Ethernet
Port LEDs

Port
Link
LEDs

FC I/O Blade
Status LEDs

Scalar i500 User’s Guide

FC I/O Fan
Blade LED

Ethernet Expansion Blade
Status LEDs

501

Chapter 13 Troubleshooting
Interpreting LEDs

Table 12 Blade Status LEDs

LED Color

Represents

Blade Status

Green

Library
application
code/Blade
processor
status

• Blinks once per second — Normal operation.
• Solid ON — Not operational.
• Solid OFF — Not operational (or blade is booting).
• Solid ON for 3 seconds, then blinks twice (FC I/O blade only) —
Blade firmware is downloading.
• Blinks 10 times per second (FC I/O blade only) — Identify mode (per
user request, to distinguish it from other blades; see Identifying FC
I/O Blades on page 496).

Amber

Health status

• Solid OFF — Normal operation.
• Blinks once per second (LCB only) — Library application code is not
operating or firmware upgrade/downgrade is in progress on existing
compact flash.
• Solid ON —
• LCB — Failure OR blade is booting up or initial firmware update
on new compact flash. If solid ON for more than 10 minutes, the
LCB may need to be replaced.
• FC I/O Blade — Failure OR blade is booting up or blade firmware
is autoleveling.
• FC I/O Fan Blade — There may be one or more problems,
including: fan speed is too high or too low; temperature is too high;
there is a faulty fan speed sensor; or there is a power control
problem.
• Ethernet Expansion blade — Failure OR blade is booting up.
Note: In most cases solid ON means a failure; however, in

conjunction with the blue LED blinking once every 10 seconds, an
amber LED solid ON can be a normal condition for a short period
of time. Autoleveling takes about three minutes per blade, and
blades autolevel in series. Never remove a blade when the amber
LED is solid ON unless it has been on continuously for at least 10
minutes. Never remove an LCB while the library is powered on.

Scalar i500 User’s Guide

502

Chapter 13 Troubleshooting
Interpreting LEDs

LED Color

Represents

Blade Status

Blue

Power
Control
status

• Blinks once every 10 seconds — Normal. Blade is powered on.
• Solid ON —
• LCB — Error condition. Power off library before removing or
replacing the LCB.
• FC I/O blade — Swap mode: Blade is ready to be removed or
replaced.
• Ethernet Expansion blade — Blade is not operational.
• Solid OFF — Blade is not receiving power.
• Blinks once per second (Ethernet Expansion blade) — Powered off.
Ready to remove.

Blade Port LEDs

13

This section describes blade port LEDs.
LCB Ethernet Hub Port LED

13

The LED for an Ethernet hub port is located above the port. Use Table 13
to interpret Ethernet hub link activity on an LCB.

Table 13 LCB Ethernet Hub
Link Activity

LED Color

Represents

Fibre Port Link Status

Amber

Link and activity

• Solid ON — The link is up.
• Blinks — The link is up and currently transmitting
commands.

Fibre Port Link LED on FC I/O Blades

13

A fibre port link LED on a FC I/O blade shows the current state of an FC
link and indicates whether or not the link is ready to transmit commands.

Scalar i500 User’s Guide

503

Chapter 13 Troubleshooting
Interpreting LEDs

The link LED for an FC I/O blade fibre port is located either below or
above the port. For each link LED pair on the FC I/O blade, the LED on
the left belongs to the fibre port below. The LED on the right belongs to
the fibre port above. Black lines on the FC I/O blade faceplate may
indicate which LED belongs to which port.
Use Table 14 to interpret Fibre Channel link activity on an FC I/O blade.

Table 14 Fibre Port Link LED
on FC I/O Blade

LED Color

Represents

Fibre Port Link Status

Green

Link and activity

• Blinking – Link with activity.
• OFF – No link or link with constant activity*.
• Solid ON – Blade is initializing.

*

LED flashing increases as the activity increases and can actually appear off if the activity is high enough. Also,
when the blade boots up, the link LEDs are all on until firmware initializes the ports, at which time they turn off
until the port transmitter is enabled and link is acquired.

Ethernet Expansion Blade Ethernet Port LEDs

13

Table 15 Ethernet Expansion
Blade Ethernet Port Link LED
States

LED Color

Blade Status

Green

Solid ON — Link is up; data can be sent or received through the Ethernet port.
Solid OFF — Link is down; data cannot be sent or received through the Ethernet port.

Amber

Blinks at irregular intervals — Data activity is occurring through the Ethernet port.
Solid OFF — No data activity is occurring through the Ethernet port.

Scalar i500 User’s Guide

504

Chapter 13 Troubleshooting
Interpreting LEDs

Servicing the LCB Based
on LED Status
13

Tape Drive LEDs

13

1 Observe the blinking patterns of the LEDs for at least 30 seconds.
2 Capture a snapshot of the library, and send it to Quantum Technical
Support for analysis.

RAS tickets typically report all problems related to tape drives, including
error codes and TapeAlerts. By observing the blinking pattern of LEDs on
tape drives, however, you can discern which operation the tape drive is
currently performing.
Figure 71 shows where the tape drive LEDs and the fibre port link LED
are located.

Figure 71 Location of Tape
Drive LEDs

1

Fibre Port LED

2

Tape Drive LEDs

Use Table 16 to interpret tape drive activity:

Scalar i500 User’s Guide

505

Chapter 13 Troubleshooting
Interpreting LEDs

Table 16 Tape Drive LEDs

LED Color

Represents

Tape Drive Status

Green

Processor activity

• Blinks once per second — Normal operation.
• Solid ON/ Solid OFF — Tape drive’s main processor is not
operating.
• 10 blinks per second — Identify mode (see Identifying Tape
Drives on page 492).
• Blinks 3 times in 3 seconds, then pauses (solid off), and then
repeats — Tape drive is initializing.
• Solid on for 3 seconds, then blinks twice — Tape drive
firmware is downloading.
• 2 quick blinks within 1.25 seconds; then on solid for 1.25
seconds; repeat — Drive sled firmware is downloading.

Amber

Blue

Health of the tape
drive

• Solid OFF — Normal operation.

Power control
status

• Blinks once every 10 seconds — Normal operation.

• Solid ON — Drive has failed.

• Solid ON — Offline. Ready to be removed or replaced.
• Solid OFF — Tape drive is not receiving power.

Scalar i500 User’s Guide

506

Chapter 13 Troubleshooting
Interpreting LEDs

Tape Drive Fibre Port
Link LED
13

The fibre port link LED shows the current state of the FC link and
indicates whether or not the link is ready to transmit commands. The
fibre port link LED on a tape drive is located on the rear of the tape drive,
beside the fibre port.
Use Table 17 to interpret FC link activity:

Table 17 Fibre Port Link
Status

LED Color

Represents

Fibre Port Link Status

Green

Loop initialization
protocol (LIP) and
activity

• Solid ON — Loop initialization protocol (LIP) has
occurred.

Amber

Online and light detected

• Solid ON — The library has enabled the tape drive data
bus, and it can detect light through a fibre optic cable.

No color

No activity or no light
detected

• Solid OFF — Either the tape drive is off or the tape drive
cannot detect light through a fibre optic cable (which is
equivalent to a missing fibre cable). If the tape drive is
offline, the tape drive’s blue status LED will be solidly
lit.

Scalar i500 User’s Guide

• Blinks at regular intervals — Host command/data
activity is occurring.

507

Chapter 13 Troubleshooting
Interpreting LEDs

Power Supply LEDs

13

RAS tickets typically report all problems related to power supplies. You
can also observe the blinking pattern of LEDs on power supplies to see if
the they are functioning appropriately.
Power supply LEDs indicate status by the rate at which they blink. The
color of the LED identifies the area of the component being reported.
Use Table 18 to interpret power supply activity.

Table 18 Power Supply Status

LED Color
and
Location
Green
(top)

Represents

Power Supply Status

AC OK

• Solid ON — The power supply’s AC input is above the minimum
requirements to operate.
• Solid OFF — The power supply’s AC input is below the minimum
requirements to operate.

Green
(middle)

DC OK

Blue
(bottom)

Standby

• Solid ON — The power supply’s output voltage is within regulation.
• Solid OFF — The power supply’s output voltage is not within
regulation.
• Solid OFF — Normal.
• Solid ON — Swap mode: Ready to be removed or replaced.
In the RAS tickets associated with the defective power supply, record
both the number of the module and the number of the power supply
connected to that module.
The expansion modules are numbered according to their position in
relation to the control module. The control module is assigned the
number 0. All expansion modules stacked beneath the control module are
assigned a negative number, while expansion modules stacked above the
control module are assigned a positive number. For example, expansion
module -2 is the second expansion module beneath the control module,
while expansion module +2 is the second expansion module above the
control module.
Each module can have up to two power supplies. The power supply on
the left is #1, while the power supply on the right is #2.

Scalar i500 User’s Guide

508

Chapter 13 Troubleshooting
Using the Installation Verification Test

Using the Installation Verification Test
Administrators can run the Installation Verification Test (IVT) following
a library service action to determine if the library is ready for production
use. Examples of such library service actions include installing a new
library or replacing a FRU or CRU.

Note:

IVT is optimized for library firmware versions 520G and above
and libraries built after July 1, 2008 (serial numbers with last
four digits 8602 and above).
• If your library was built on or before July 1, 2008, and you
are running firmware version 520G or above, you will not
be able to run the IVT test, even though the selection is
available.
• If your library was built on or before July 1, 2008, and you
are running firmware version 500G or below, you can run
the test, but it is not recommended because it may produce
erroneous results.

A new IVT Log is created each time you run IVT. The log reports detailed
information about library readiness and indicates where specific
marginal conditions and failures are located in the library subsystems if
there are any.
The full IVT is divided into five subtests. You may choose to run only
certain subtests depending on the amount of time available and your area
of interest. The full IVT may take up to five and one-half hours to
complete for a maximum configured library that includes five modules,
five I/E stations and 18 drives.
• The Robot test evaluates the basic functionality of the library robotics
assembly, including the picker assembly and the Y-carriage
assembly, the barcode scanner and the calibration sensors. Time
required to complete the Robot test is five minutes.
• The Frame test assesses the control and expansion module
configuration and alignment.Time required to complete the Frame
test is three minutes per module.

Scalar i500 User’s Guide

509

Chapter 13 Troubleshooting
Using the Installation Verification Test

• The I/E Station test assesses the configuration and functionality of
each I/E station. Time required to compete the I/E Station test is
three minutes per I/E station.
• Drives performs functional tests on the library drives. Time required
to complete the Drives test is 15 minutes per drive.
• Tour moves a scratch data cartridge through all storage slots in the
extreme library locations. It also scans the top and bottom-most slots
in the library. Time required to complete the Tour is five minutes per
module.
Details on running the IVT subtests include:
• All IVT subtests are preselected by default. Clear the check box next
to a subtest name to exclude that test from this IVT run. Select Apply
when you are ready to run the IVT.
• The Robot, Drives and Tour subtests each require that you to provide
a scratch data cartridge before the test can begin. If you select one of
these subtests, you will be prompted to place a scratch data cartridge
into the top I/E station slot. When you close the I/E station, the
Assign I/E screen appears if the Manual Cartridge Assignment setting is
enabled on the operator panel System Settings screen (Tools > System
Settings). Assign the new scratch data cartridge to the System
partition, and then select Apply.
• The Drives subtest only tests those tape drives that have the same
media type as the scratch data cartridge. For example, if the scratch
data cartridge is LTO-3, then all tape drives that are not LTO-3 will be
skipped in the Drives test. If the tape drives in the library have
different media types, you must run the Drives test multiple times
with a different scratch data cartridge for each tape drive media type.
• If a subtest is missing required resources (for example, scratch data
cartridges) the subtest will fail.
• The IVT starts by performing an inventory of the library. The
inventory is recorded in the IVT log along with the test results.
• Select Details on the Library Test Progress screen to see the IVT
results. If the IVT is still running, you will only see results for tests
that have completed.
• Select Stop on the Library Test Progress screen to cancel the current
IVT run between subtests. The last issued commands will complete
before library control is returned.

Scalar i500 User’s Guide

510

Chapter 13 Troubleshooting
Using the Installation Verification Test

• Once the selected tests are complete, select Next. You can choose to
view the detailed IVT log or e-mail the detailed IVT log. Make your
choice and select Next.
The IVT test cannot be performed from the Web client. The path to open
the appropriate screen is as follows:
• From the operator panel, select Tools > Library Tests > Installation &
Verification Tests.

Viewing the IVT Logs 13

A new IVT log is created each time you run IVT. The log reports detailed
information about library readiness and indicates where specific
marginal conditions and failures are located in the library subsystems if
there are any. You can view a summary or detailed version of a log
following an IVT run.
The paths to open the appropriate screens are as follows:
• From the Web client, select Reports > Log Viewer > Installation
Verification Test Summary Log.
• From the Web client, select Reports > Log Viewer > Installation
Verification Test Detailed Log.
• From the operator panel, select Tools > Library Tests > View Last
Summary Log.
• From the operator panel, select Tools > Library Tests > View Last
Detailed Log.

Saving and E-mailing the
IVT Logs
13

You can save and e-mail the summary and detailed IVT logs as a text file
using the Web client. From the operator panel, you can e-mail the
detailed IVT log as a text file.
The path to open the appropriate screens are as follows:
• From the Web client, select Reports > Log Viewer > Installation
Verification Test Summary Log.
• From the Web client, select Reports > Log Viewer > Installation
Verification Test Detailed Log.
• From the operator panel, select Tools > Library Tests > E-mail Last
Detailed Log.

Scalar i500 User’s Guide

511

Chapter 13 Troubleshooting
Using the Installation Verification Test

Running Library Demo 13

Administrators can run Library Demo, a simple way to test robotics
functionality following a FRU or CRU replacement. It shows the library’s
ability to correctly move a scratch data cartridge from an I/E station to
randomly selected open storage slots until the demonstration is stopped.
Details on running Library Demo include:
• Media in the storage magazines are not affected by the
demonstration. The scratch data cartridge is returned to the I/E
station following each cycle of 20 moves or when the demonstration
is stopped.
• Before running Library Demo, ensure that no host applications are
accessing the library.
• After you select Library Demo on the Tools > Library Tests screen, you
will be prompted to place a scratch data cartridge into the top I/E
station slot. The library robot will use this cartridge to perform its
moves during the demonstration.
• When you close the I/E station, the Assign I/E screen appears if the
Manual Cartridge Assignment setting is enabled on the operator panel
System Settings screen (Tools > System Settings). Assign the new
scratch data cartridge to the System partition, and then select Apply.
• Before the demonstration starts, the library may perform an
inventory. If the screen shows the flashing “Library Not Ready”
message, which indicates that an inventory is occurring, wait until
the library is ready before you select Apply to begin Library Demo.
• The operator panel will show that the demonstration is in progress.
There is an intentional delay of two seconds between move media
commands to prevent unnecessary wear on the robotics
• To stop the demonstration, select Stop on the Library Demo screen.
The last issued commands will complete before the demonstration is
stopped and library control is returned. The operator panel will
display a “Demo Being Stopped” message.
Library Demo cannot be performed from the Web client. The path to
open the appropriate screen is as follows:
• From the operator panel, select Tools > Library Tests > Library Demo.

Scalar i500 User’s Guide

512

Chapter 13 Troubleshooting
Configuring the Internal Network

Configuring the Internal Network
When installing your library, you need to make sure that the external
network setting is different than the internal network setting on the
library. If the external and internal network settings are the same, the
Web client cannot connect to the library. If DHCP is enabled or you do
not know what your external network setting is, check with your network
administrator.
From the operator panel, you can change the setting of your internal
network using the Internal Network Configuration screen. Select the new
internal IP address from the list on the screen.
The screen is only accessible from the operator panel. The path to open
the appropriate screen is:
• From the operator panel, select Tools > Internal Network.

Library Diagnostics
The Diagnostics menu contains a number of tests you can run to
determine if tape drives, robotics, and Q-EKM path (if Q-EKM is
licensed) are working as they should. The following sections describe the
Diagnostics tests:
• Drive Diagnostics on page 514
• Robotics Diagnostics on page 517
• Using EKM Path Diagnostics on page 183 (only available if EKM is
licensed on the library)
Notes about Diagnostics include:
• Only users with Admin level privileges can access Diagnostics.
• Only one user can be logged into Diagnostics at a time. Entering
Diagnostics disconnects all other library users with the same or lower
privileges, on both the operator panel and the Web client. When one
Admin-level user is logged into Diagnostics, all other users with

Scalar i500 User’s Guide

513

Chapter 13 Troubleshooting
Drive Diagnostics

Admin level privileges and below will be unable to log in to the
library and will get an error message stating that Diagnostics is in
progress.
• Entering Diagnostics takes all your library partitions offline. Be sure
any crucial operations have stopped before you enter Diagnostics.
When you exit Diagnostics, your partitions return to the
online/offline status they were in previously.
Diagnostics cannot be performed from the operator panel (the only
exception is the Drive Reset operation; see Drive Reset on page 514). The
path to open the appropriate screen is as follows:
• From the Web client, select Tools > Diagnostics.

Drive Diagnostics
Drive diagnostics are separated into the following categories:
• Drive Tests — Tests any tape drive and does not require you to use a
scratch tape.
• Media Tests — Tests only IBM tape drives and requires you to insert
a scratch tape in the top I/E station slot to perform the test.
• Ethernet Expansion Blade Control — Allows you to power cycle an
Ethernet Expansion blade and remove an Ethernet Expansion blade
from the library’s configuration.

Drive Tests

13

The Drive Tests currently include only one test, the Drive Reset
operation.
Drive Reset

13

The Drive Reset operation power cycles the tape drive while the tape
drive remains in the drive sled in the library. You may want to perform a
reset if a tape drive does not come ready or it is not behaving properly
(for example, if a tape is stuck in the drive and will not unload).

Scalar i500 User’s Guide

514

Chapter 13 Troubleshooting
Drive Diagnostics

After the reset operation completes, the tape drive is rebooted and
reconfigured. This takes about 60 seconds. Wait 60 seconds before
performing further drive operations.

Note:

This operation should not be performed concurrently by
multiple administrators. You can access the screen, but you
cannot apply changes while another administrator is
performing the same operation.

The paths to open the appropriate screens are as follows:
• From the Web client, select Tools > Diagnostics, then select Drives >
Drive Tests > Drive Reset.
• From the operator panel, select Tools > Drive Mgmt > Reset drives.

Media Tests

13

The Media Tests are drive tests that require you to insert a scratch or
suspect tape into the library’s top (uppermost) I/E station slot. You can
only run these tests on IBM tape drives. The following tests are available:
• Drive Self Test — Performs the drive’s Power On Self Test (POST) to
make sure that drive hardware is working properly.
• Read/Write Test — Reads and writes 96 wraps worth of data in each of
the scratch tape’s four data sections. During the test, the drive
overwrites the data on the scratch tape.
• Fast Read/Write Test — Reads and writes two wraps worth of data in
each of the scratch tape’s four data sections. During the test, the drive
overwrites the data on the scratch tape.
• Media Test — Run this test if you suspect media damage in a tape
cartridge. Since media damage usually comes from the tape edges,
this test reads and writes two wraps worth of data on each of the two
outside data bands on both edges of the tape for the entire length of
the tape. For this test, insert the suspect cartridge in the top I/E
station slot. The data will be overwritten on the suspect cartridge.
Media tests cannot be performed from the operator panel. The path to
open the appropriate screen is as follows:
• From the Web client, select Tools > Diagnostics > Drives > Media Tests.

Scalar i500 User’s Guide

515

Chapter 13 Troubleshooting
Drive Diagnostics

Ethernet Expansion
Blade Control

13

The Ethernet Expansion Blade Control menu allows you to perform the
following functions:
• Power Cycling the Ethernet Expansion Blade
• Removing an Ethernet Expansion Blade from the Library’s
Configuration

13

Power Cycling the Ethernet Expansion Blade

Administrators can power cycle individual Ethernet Expansion blades in
the library. You might want to power cycle an individual Ethernet
Expansion blade when troubleshooting, such as when resolving a
Reliability, Availability, and Serviceability (RAS) ticket.
From the EE Blade Control screen, click the Cycle button corresponding to
the Ethernet Expansion blade you want to power cycle.
Note:

Power cycling an Ethernet Expansion blade may cause key
exchange failures if FIPS is enabled.

It takes approximately 1 minute to power cycle an Ethernet Expansion
blade. The status displays as “Booting” during the power cycle.
You can only power cycle the Ethernet Expansion blade from the Web
client. The path to open the appropriate screen is as follows:
• From the Web client, select Tools > Diagnostics > Drives > EE Blade
Control.
Removing an Ethernet Expansion Blade from the Library’s
Configuration

13

This feature is described in detail in Permanently Removing or Relocating
an Ethernet Expansion Blade on page 472.

Scalar i500 User’s Guide

516

Chapter 13 Troubleshooting
Robotics Diagnostics

Robotics Diagnostics
The Robotics diagnostics currently include only one test, the Get/Put
Test.
Get/Put Test

13

The Get/Put Test requires the robot to remove one tape cartridge from
the top I/E station slot, and then put the tape cartridge back into the same
slot. To run this test, you must insert a tape into the library’s top
(uppermost) I/E station slot.
Robotics tests cannot be performed from the operator panel. The path to
open the appropriate screen is as follows:
• From the Web client, select Tools > Diagnostics > Robotics > Robotics
Get/Put Test.

Scalar i500 User’s Guide

517

Chapter 14

14

Working With Cartridges
and Barcodes

This chapter describes how to work with cartridges and barcodes. When
working with tape cartridges, certain considerations should be taken into
account. For example, all tape cartridges in the library must have a
barcode label. In addition, when loading your library, you should be
aware of whether or not your cartridges are write-protected.
This chapter discusses these types of items in general terms. See Library
Specifications on page 524 for information on what type of tape
cartridges are supported for each drive type.
This chapter covers:
• Handling Cartridges Properly
• Write-Protecting Cartridges
• Barcode Label Requirements
• Supported Barcode Formats
• Installing Barcode Labels

Scalar i500 User’s Guide

518

Chapter 14 Working With Cartridges and Barcodes
Handling Cartridges Properly

Handling Cartridges Properly
To ensure the longest possible life for your cartridges, follow these
guidelines:
• Select a visible location to post procedures that describe proper
media handling.
• Ensure that anyone who handles cartridges has been properly trained
on all procedures.
• Do not drop or strike cartridges. Excessive shock could damage the
internal contents of cartridges or the casings themselves, rendering
the cartridges unusable.
• Do not expose cartridges to direct sunlight or sources of heat,
including portable heaters and heating ducts.
• Store cartridges in a location that is as free from dust as possible. Dust
can damage or degrade performance of tape media.
• For external long-term vaulted storage, store cartridges in a vertical
orientation.
• If cartridges must be stacked horizontally for moving and handling,
do not stack cartridges more than five high.
• The operating temperature range for Linear Tape Open (LTO)
cartridges is 50ºF to 113ºF (10ºC to 45ºC). The operating relative
humidity range is 10% to 80% (non-condensing). The storage
temperature range is 60.8ºF to 89.6ºF (16º to 32ºC). Temperatures
above 125.6ºF (52ºC) can cause permanent damage.
• If cartridges have been exposed to temperatures outside the ranges
specified above, stabilize the cartridges at room temperature for the
same amount of time they were exposed to extreme temperatures or
24 hours, whichever is less.
• Do not place cartridges near sources of electromagnetic energy or
strong magnetic fields, such as computer monitors, electric motors,
speakers, or x-ray equipment. Exposure to electromagnetic energy or
magnetic fields can destroy data and the embedded servo code
written on the media by the cartridge manufacturer, rendering the
cartridges unusable.
• Place barcode labels only in the designated slots on the cartridges.

Scalar i500 User’s Guide

519

Chapter 14 Working With Cartridges and Barcodes
Write-Protecting Cartridges

• If you ship cartridges, ship them in their original packaging or
something stronger.
• Do not insert damaged cartridges into tape drives.
• Do not touch the tape or tape leader.
Caution:

Do not degauss cartridges that you intend to reuse.

Write-Protecting Cartridges
All cartridges have a write-protect (write-inhibit) switch to prevent
accidental erasure or overwriting of data. Before loading a cartridge into
the library, make sure that the write-protect switch is positioned correctly
(either on or off).
Slide the red or orange write-protect switch to the right so that the
padlock shows in the closed position. The switch is located on the left
side of the cartridge front.

Barcode Label Requirements
Cartridges must have an external barcode label that is machine readable.
Quantum-supplied barcode labels provide the best results. Barcode labels
from other sources can be used, but they must meet the following
requirements:
Note:

Checksum characters are not supported on barcode labels.

• ANSI MH10.8M-1983 Standard.
• Font: Code 39 (3 of 9).
• Allowable characters: Uppercase letters A to Z and numeric values
0 to 9.
Scalar i500 User’s Guide

520

Chapter 14 Working With Cartridges and Barcodes
Supported Barcode Formats

• Number of characters: 5 to 16 (default for LTO is 6+2).
Note:

A maximum of 12 characters is recommended. A barcode
label with more than 12 characters may not be printable
according to the Code 39 label specifications for the tape
cartridge area to which the label is attached. The effective
tape cartridge barcode label length, including any media
ID, may be limited to a maximum of 12 characters.

• Background reflection: Greater than 25 percent.
• Print contrast: Greater than 75 percent.
• Ratio: Greater than 2.2.
• Module: Minimum .254 mm (10 mil).
• Print tolerance: ± 57 mm.
• Length of the rest zones: 5.25 mm ± 0.25 mm.
• No black marks may be present in the intermediate spaces or rest
zones.
• No white areas may be present on the bars.

Supported Barcode Formats
Quantum supplies industry standard LTO barcode labels with a length of
6 + 2 corresponding to the Standard Six and Plus Six formats listed below.
For advanced uses, your Quantum library supports label lengths of up to
16 characters allowing you to create custom labels. Refer to Barcode Label
Requirements on page 520 for label details.
The library supports the following tape cartridge barcode formats:
• Standard — Five to 16 characters total, including a barcode number
and optional two-character media ID. If a media ID is included, the
label must have a five to 14 character barcode number followed by a
media ID; for example, “XXXXXXXXXXXXXXL4”. If a media ID is not
included, the label must have a five to 16 character barcode number;
for example, “XXXXX” or “XXXXXXXXXXXXXXXX”. Only the
barcode number is reported to the host.
Scalar i500 User’s Guide

521

Chapter 14 Working With Cartridges and Barcodes
Installing Barcode Labels

• Standard Six — Six character barcode number with or without a twocharacter media ID; for example, “XXXXXXL4” or ”XXXXXX”. Only
the six character barcode number is reported to the host.
• Plus Six — Six character barcode number followed by a two-character
media ID; for example, “XXXXXXL4”. The six character barcode and
media ID are reported to the host.
• Extended — Five to 16 characters total, including a barcode number
and optional two-character media ID. All characters are reported to
the host, regardless of the barcode label having a media ID or not. If a
media ID is included, the label must have a five to 14 character
barcode followed by a media ID; for example,
“XXXXXXXXXXXXXXL4”. If a media ID is not included, the label
must have a five to 16 character barcode number; for example,
“XXXXX” or “XXXXXXXXXXXXXXXX”.
• Media ID Last — Five to 14 character barcode number followed by a
two-character media ID, for example, “XXXXXXXXXXXXXXL4”. The
media ID is reported to the host last, as in “XXXXXXXXXXXXXXL4”.
• Media ID First — Five to 14 character barcode number followed by a
two-character media ID, for example, “XXXXXXXXXXXXXXL4”. The
media ID is reported to the host first, as in “L4XXXXXXXXXXXXXX”.

Installing Barcode Labels
Each cartridge in the library must have an external label that is machine
readable to identify the barcode. Most manufacturers offer cartridges
with the labels already applied or with the labels included that you can
attach.
All barcode labels must be applied to the front of a cartridge. Peel off the
label and place it on the cartridge. The label must be placed entirely
within the recessed area on the cartridge. Verify that the label is oriented
so that the numbers appear above the barcode (see Figure 72 on
page 523).
Place the barcode label as level as possible in the provided space for the
label. If the label is not placed horizontally level, barcode label scan/read
operations may encounter difficulties reading the label.

Scalar i500 User’s Guide

522

Chapter 14 Working With Cartridges and Barcodes
Installing Barcode Labels

The cartridge cannot have any stickers or labels attached to the top or
bottom because if the labels come loose, they can get caught in the tape
drives or become unreadable by the scanner.
Caution:

Do not place a barcode label or any labels on the top or
bottom of a cartridge. Doing so can cause the tape
cartridge and tape drive operations to fail.

Figure 72 Barcode Label
Orientation

Scalar i500 User’s Guide

523

Appendix A

Library Specifications

A

Scalar i500 libraries follow the specifications described in this chapter.

Supported Components
The Scalar i500 library supports the following components.
Supported Cartridges

• LTO-1 (read-only in LTO-3 drives)
• LTO-2 (read/write in LTO-2 and LTO-3 drives; read-only in LTO-4
drives)
• LTO-3 (read/write in LTO-3 and LTO-4 drives; read-only in LTO-5
drives; supports write-once, read-many (WORM) functionality)
• LTO-4 (read/write in LTO-4 and LTO-5 drives; supports WORM
functionality)
• LTO-5 (read/write in LTO-6 drives; supports WORM functionality)
• LTO-6 (read/write in LTO-6 drives; supports WORM functionality)

Scalar i500 User’s Guide

524

Appendix A Library Specifications
Supported Components

Supported Tape Drive
Types

• IBM LTO-2 (SCSI and Fibre Channel)
• RoHS-compliant IBM LTO-3 (SCSI and Fibre Channel)
• RoHS-compliant HP LTO-4 (Fibre Channel and SAS)
• RoHS-compliant IBM LTO-4 (SCSI, Fibre Channel, and SAS)
• HP LTO-5 Dual Port Fibre Channel Tape Drive
• HP LTO-5 Single Port SAS Tape Drive
• IBM LTO-5 Single Port Fibre Channel Tape Drive
• LTO-5 Dual Port SAS Tape Drive
• LTO-6 Single Port Fibre Channel Tape Drive
• LTO-6 Dual Port SAS Tape Drive

Supported SAS Cable

SFF-8088

Library Robot Control

Logical Unit Number (LUN)

Connectivity

Native drive interface

Power

350W with optional redundant power supply and line cord

Library Management

• Operator panel touch screen
• Web client
• SNMP protocol
• SMI-S protocol

Scalar i500 User’s Guide

525

Appendix A Library Specifications
Library Capacity

Library Capacity
Library capacity is as follows.
Note:

Slot counts in this user’s guide do not include five inaccessible
slots in the bottom row of any library configuration. For more
information about these slots, see Unused Slots on page 247.

5U

14U

23U

32U

41U

Maximum Available
Storage Slots (Including
I/E Station Slots)

41

133

225

317

409

I/E Station Slots
Available

0, 6

0, 6, 12, 18

0, 6, 12,
18, 24, 30

0, 6, 12, 18,
24, 30, 36, 42

0, 6, 12, 18,
24, 30, 36, 42,
48, 54

Maximum Drive
Capacity

2

6

10

14

18

Maximum Power
Supplies

2

4

6

8

10

Maximum Partitions

2

6

10

14

18

Maximum FC I/O
Blades

0

2

4

4

4

Scalar i500 User’s Guide

526

Appendix A Library Specifications
Environmental Requirements

Environmental Requirements
The environmental requirements for the library are listed below.
Note:

Temperature ranges apply to product inlet temperatures, not
necessarily to ambient room temperatures. Airflow restrictions
or other heat-generating equipment within the rack enclosure
may cause a rise over ambient room temperatures.

Operating

Non-Operating

Storage

Altitude

Up to 10,000 ft.
(3,048 m)

Up to 10,000 ft.
(3,048 m)

Up to 10,000 ft.
(3,048 m)

Temperature

50º to 104º F

50º to 113º F

–40º to 150º F

(10º to 40º C)

(10º to 45º C)

(–40º to 65º C)

20 to 80%,
non-condensing

10 to 90%,
non-condensing

0 to 95%,
non-condensing

Relative Humidity

Electrical Requirements
Electrical requirements for the library are: 100–240 VAC, 50–60 Hz

Scalar i500 User’s Guide

527

Appendix A Library Specifications
Dimensions

Dimensions

Library Configuration

Rack
Height

HxWxD

5U control module

5U

8.6 in. x 17.4 in. x 31.4 in
(21.9 cm x 44.2 cm x 79.8 cm)

9U expansion module

9U

15.8 in. x 17.4 in. x 31.4 in
(40 cm x 44.2 cm x 79.8 cm)

5U control module + (1) 9U
expansion module

14U

5U control module + (2) 9U
expansion modules

23U

5U control module + (3) 9U
expansion modules

32U

5U control module + (4) 9U
expansion modules

41U

24.4 in. x 17.4 in. x 31.4 in
(61.9 cm x 44.2 cm x 79.8 cm)
40.1 in. x 17.4 in. x 31.4 in
(101.9 cm x 44.2 cm x 79.8 cm)
55.9 in. x 17.4 in. x 31.4 in
(141.9 cm x 44.2 cm x 79.8 cm)
71.6 in. x 17.4 in. x 31.4 in
(181.9 cm x 44.2 cm x 79.8 cm)

Component Weights

Scalar i500 User’s Guide

Component

Weight

Drive Sled

10 lbs (4.6 kg)

Power Supply

5 lbs (2.3 kg)

5U Chassis (empty)

60 lbs (27.2 kg)

528

Appendix A Library Specifications
Library Power Consumption and Heat Output

Component

Weight

9U Chassis (empty)

65 lbs (29.5 kg)

5U Packaging Kit

20 lbs (9 kg)

9U Packaging Kit

24 lbs (10.9 kg)

14U Packaging Kit

40 lbs (18 kg)

Library Power Consumption and Heat Output
The typical library power consumption (Watts/hour) and heat output
(BTU/hour) is listed below.
Note:

“Typical” values for tape drives assumes tape drives are
writing.

Typical Power
Consumption
(kW/Hour)

Typical Heat
Output
(BTU/Hour)

Scalar I500 Library with Robot and LCB (no tape drives installed;
robot moving; LCB installed)

0.079

269.0

UDS3 IBM LTO-2 Drive Sled Module (SCSI)

0.029

99.0

UDS3 IBM LTO-2 Drive Sled Module (Fibre Channel)

0.032

109.2

UDS3 IBM LTO-3 Drive Sled Module (SCSI)

0.027

92.1

UDS3 IBM LTO-3 Drive Sled Module (Fibre Channel)

0.029

99.0

UDS3 IBM LTO-4 Drive Sled Module (SCSI)

0.038

129.7

UDS3 IBM LTO-4 Drive Sled Module (Fibre Channel)

0.040

136.5

Library Configuration
Subassembly Power Consumption:

Scalar i500 User’s Guide

529

Appendix A Library Specifications
Library Power Consumption and Heat Output

Typical Power
Consumption
(kW/Hour)

Typical Heat
Output
(BTU/Hour)

UDS3 IBM LTO-4 Drive Sled Module (SAS)

0.038

129.7

UDS3 HP LTO-4 Drive Sled Module (Fibre Channel)

0.037

126.2

UDS3 HP LTO-4 Drive Sled Module (SAS)

0.035

119.4

UDS3 IBM LTO-5 Drive Sled Module (Fibre Channel)

0.048

163.8

UDS3 HP LTO-5 Drive Sled Module (Fibre Channel)

0.030

102.4

UDS3 HP LTO-5 Drive Sled Module (SAS)

0.028

95.5

UDS3 IBM LTO-6 Drive Sled Module (Fibre Channel)

0.034

116.0

UDS3 IBM LTO-6 Drive Sled Module (SAS)

0.032

109.2

UDS3 HP LTO-6 Drive Sled Module (Fibre Channel)

0.030

102.4

UDS3 HP LTO-6 Drive Sled Module (SAS)

0.028

95.5

Fibre Channel I/O Blade

0.080

272.8

Ethernet Expansion Blade

0.010

34.1

Minimum (no drives installed; robot not moving)

0.047

160.0

Maximum (2 drives writing; robot moving)

0.166

565.0

Minimum (no drives installed; robot not moving)

0.012

41.0

Maximum (4 drives writing; 2 Fibre-Channel I/O blades
installed; robot moving)

0.256

879.0

Library Configuration

Control Module:

Expansion Module:

Scalar i500 User’s Guide

530

Appendix B

B

TapeAlert Flag Descriptions

TapeAlert is an open industry standard that flags errors and provides
possible solutions for storage devices and their media. This section
provides information about TapeAlert flags issued by tape drives,
including the identifying number, severity, recommended message, and
probable cause. Table 19 explains the severity codes, and Table 20 lists all
the existing TapeAlert flags and their descriptions.
Support for specific TapeAlert flags may vary based on tape drive type
and firmware revision. Not all tape drives support every TapeAlert.
Consult your tape drive SCSI manual for more information.
For more information on TapeAlert, see http://www.t10.org/index.html
for INCITS SCSI Stream Commands - 3 (SSC-3).

Table 19 TapeAlert Flag
Severity Codes

Scalar i500 User’s Guide

I

Informational.

W

Warning — The system may not be operating optimally.
Continued operation without corrective action may cause a
failure or raise critical TapeAlert flags.

C

Critical — Either a failure has already occurred or a failure is
imminent. Corrective action is required.

531

Appendix B TapeAlert Flag Descriptions

Table 20 Tape Drive
TapeAlert Flag Descriptions

Recommended Application Client
Message

No.

Flag

Severity

1

Read warning

W

The tape drive is having problems
reading data. No data has been lost, but
there has been a reduction in the
performance of the tape.

The drive is having
severe trouble
reading.

2

Write warning

W

The tape drive is having problems
writing data. No data has been lost, but
there has been a reduction in the
capacity of the tape.

The drive is having
severe trouble
writing.

3

Hard error

W

The operation has stopped because an
error has occurred while reading or
writing data which the drive cannot
correct.

The drive had a hard
read or write error.

4

Media

C

Your data is at risk:

Media can no longer
be written/read, or
performance is
severely degraded.

1 Copy any data you require from this
tape.
2 Do not use this tape again.

Probable Cause

3 Restart the operation with a different
tape.
5

Read failure

C

The tape is damaged or the drive is
faulty. Call the tape drive supplier help
line.

The drive can no
longer read data
from the tape.

6

Write failure

C

The tape is from a faulty batch or the
tape drive is faulty:

The drive can no
longer write data to
the tape.

1 Use a good tape to test the drive.
2 If the problem persists, call the tape
drive supplier help line.

Scalar i500 User’s Guide

532

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

7

Media life

W

Recommended Application Client
Message
The tape cartridge has reached the end
of its calculated useful life:
1 Copy any data you need to another
tape.

Probable Cause
The media has
exceeded its specified
life.

2 Discard the old tape.
8

Not data grade

W

The tape cartridge is not data-grade.
Any data you write to the tape is at risk.
Replace the cartridge with a data-grade
tape.

The drive has not
been able to read the
MRS* stripes.

9

Write protect

C

You are trying to write to a writeprotected cartridge. Remove the writeprotection or use another tape.

Write command is
attempted to a writeprotected tape.

10

Media removal
prevented

I

You cannot eject the cartridge because
the tape drive is in use. Wait until the
operation is complete before ejecting the
cartridge.

Manual or software
unload attempted
when prevent media
removal on.

11

Cleaning media

I

The tape in the drive is a cleaning
cartridge.

Cleaning tape loaded
into drive.

12

Unsupported
format

I

You have tried to load a cartridge of a
type which is not supported by this
drive.

Attempted load of
unsupported tape
format.

13

Recoverable
mechanical
cartridge failure

C

The operation has failed because the
tape in the drive has experienced a
mechanical failure:

Tape snapped/cut or
other cartridge
mechanical failure in
the drive where
medium can be
demounted.

1 Discard the old tape.
2 Restart the operation with a different
tape.

Scalar i500 User’s Guide

533

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

14

Unrecoverable
mechanical
cartridge failure

C

Recommended Application Client
Message
The operation has failed because the
tape in the drive has experienced a
mechanical failure:
1 Do not attempt to extract the tape
cartridge.
2 Call the tape drive supplier help line.

Probable Cause
Tape snapped/cut or
other cartridge
mechanical failure in
the drive where
medium cannot be
demounted.

15

Memory chip in
cartridge failure

W

The memory in the tape cartridge has
failed, which reduces performance. Do
not use the cartridge for further write
operations.

Memory chip failed
in cartridge.

16

Forced eject

C

The operation has failed because the
tape cartridge was manually demounted
while the tape drive was actively writing
or reading.

Manual or forced
eject while drive
actively writing or
reading.

17

Read-only
format

W

You have loaded a cartridge of a type
that is read-only in this drive. The
cartridge will appear as write protected.

Media loaded that is
read-only format.

18

Tape directory
corrupted on
load

W

The directory on the tape cartridge has
been corrupted. File search performance
will be degraded. The tape directory can
be rebuilt by reading all the data on the
cartridge.

Tape drive powered
down with tape
loaded, or permanent
error prevented the
tape directory being
updated.

19

Nearing media
life

I

The tape cartridge is nearing the end of
its calculated life. It is recommended
that you:

Media may have
exceeded its specified
number of passes.

1 Use another tape cartridge for your
next backup.
2 Store this tape cartridge in a safe
place in case you need to restore data
from it.

Scalar i500 User’s Guide

534

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

Recommended Application Client
Message

20

Cleaning
required

C

The tape drive needs cleaning:
1 If the operation has stopped, eject the
tape and clean the drive.

Probable Cause
The drive thinks it
has a head clog or
needs cleaning.

2 If the operation has not stopped, wait
for it to finish and then clean the
drive.
Check the tape drive user’s manual for
device-specific cleaning instructions.
21

Cleaning
requested

W

The tape drive is due for routine
cleaning:

The drive is ready for
a periodic cleaning.

1 Wait for the current operation to
finish.
2 Then use a cleaning cartridge.
Check the tape drive user’s manual for
device-specific cleaning instructions.
22

Expired
cleaning media

C

The last cleaning cartridge used in the
tape drive has worn out:

The cleaning tape has
expired.

1 Discard the worn-out cleaning
cartridge.
2 Wait for the current operation to
finish.
3 Then use a new cleaning cartridge.
23

Invalid cleaning
tape

C

The last cleaning cartridge used in the
tape drive was an invalid type:

Invalid cleaning tape
type used.

1 Do not use this cleaning cartridge in
this drive.
2 Wait for the current operation to
finish.
3 Then use a valid cleaning cartridge.

Scalar i500 User’s Guide

535

Appendix B TapeAlert Flag Descriptions

Recommended Application Client
Message

No.

Flag

Severity

24

Retension
requested

W

The tape drive has requested a retension
operation.

The drive is having
severe trouble
reading or writing,
which will be
resolved by a
retension cycle.

25

Multi-port
interface error
on a primary
port

W

A redundant interface port on the tape
drive has failed.

Failure of one
interface port in a
dual-port
configuration (for
example, Fibre
Channel).

26

Cooling fan
failure

W

A tape drive cooling fan has failed.

Fan failure inside
tape drive
mechanism or tape
drive enclosure.

27

Power supply
failure

W

A redundant power supply has failed
inside the tape drive enclosure. Check
the enclosure user’s manual for
instructions on replacing the failed
power supply.

Redundant power
supply unit failure
inside the tape drive
enclosure or rack
subsystem.

28

Power
consumption

W

The tape drive power consumption is
outside the specified range.

Power consumption
of the tape drive is
outside specified
range.

29

Drive
preventive
maintenance
required

W

Preventive maintenance of the tape
drive is required. Check the tape drive
user’s manual for device-specific
preventive maintenance tasks or call the
tape drive supplier help line.

The drive requires
preventative
maintenance (not
cleaning).

30

Hardware A

C

The tape drive has a hardware fault:

The drive has a
hardware fault that
requires reset to
recover.

1 Eject the tape or magazine.
2 Reset the drive.

Probable Cause

3 Restart the operation.

Scalar i500 User’s Guide

536

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

Recommended Application Client
Message

31

Hardware B

C

The tape drive has a hardware fault:
1 Turn the tape drive off and then on
again.
2 Restart the operation.
3 If the problem persists, call the tape
drive supplier help line.

32

Primary
interface

W

The tape drive has a problem with the
host interface:
1 Check the cables and cable
connections.

Probable Cause
The drive has a
hardware fault that is
not read/write
related or requires a
power cycle to
recover.

The drive has
identified an
interface fault.

2 Restart the operation.
33

Eject media

C

The operation has failed:
1 Eject the tape or magazine.

Error recovery
action.

2 Insert the tape or magazine again.
3 Restart the operation.
34

Microcode
update fail

W

The microcode update has failed
because you have tried to use the
incorrect microcode for this tape drive.
Obtain the correct microcode and try
again.

Microcode update
failed.

35

Drive humidity

W

Environmental conditions inside the
tape drive are outside the specified
humidity range.

Drive humidity
limits exceeded.

36

Drive
temperature

W

Environmental conditions inside the
tape drive are outside the specified
temperature range.

Cooling problem.

37

Drive voltage

W

The voltage supply to the tape drive is
outside the specified range.

Drive voltage limits
exceeded.

38

Predictive
failure

C

A hardware failure of the tape drive is
predicted. Call the tape drive supplier
help line.

Predictive failure of
drive hardware.

Scalar i500 User’s Guide

537

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

39

Diagnostics
required

W

Recommended Application Client
Message
The tape drive may have a hardware
fault. Run extended diagnostics to verify
and diagnose the problem. Check the
tape drive user’s manual for devicespecific instructions on running
extended diagnostic tests.

Probable Cause
The drive may have a
hardware fault that
may be identified by
extended diagnostics
(i.e., SEND
DIAGNOSTIC

command).

40 –
46

Obsolete

47 –
49

Reserved

50

Lost statistics

W

Media statistics have been lost at some
time in the past.

Drive or library
powered down with
tape loaded.

51

Tape directory
invalid at
unload

W

The tape directory on the tape cartridge
just unloaded has been corrupted. File
search performance will be degraded.
The tape directory can be rebuilt by
reading all the data.

Error prevented the
tape directory being
updated on unload.

52

Tape system
area write
failure

C

The tape just unloaded could not write
its system area successfully:

Write errors while
writing the system
area on unload.

1 Copy data to another tape cartridge.
2 Discard the old cartridge.

53

54

Tape system
area read
failure

C

No start of data

C

The tape system area could not be read
successfully at load time:
1 Copy data to another tape cartridge.
The start of data could not be found on
the tape:
1 Check that you are using the correct
format tape.

Read errors while
reading the system
area on load.
Tape damaged, bulk
erased, or incorrect
format.

2 Discard the tape or return the tape to
your supplier.

Scalar i500 User’s Guide

538

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

55

Loading or
threading
failure

C

Recommended Application Client
Message
The operation has failed because the
media cannot be loaded and threaded:
1 Remove the cartridge, inspect it as
specified in the product manual, and
retry the operation.

Probable Cause
The drive is unable to
load the media and
thread the tape.

2 If the problem persists, call the tape
drive supplier help line.
56

Unrecoverable
unload failure

C

The operation has failed because the
medium cannot be unloaded:

The drive is unable to
unload the medium.

1 Do not attempt to extract the tape
cartridge.
2 Call the tape driver supplier help
line.
57

Automation
interface failure

C

The tape drive has a problem with the
automation interface:
1 Check the power to the automation
system.

The drive has
identified an
interface fault.

2 Check the cables and cable
connections.
3 Call the supplier help line if problem
persists.
58

Microcode
failure

W

The tape drive has reset itself due to a
detected microcode fault. If problem
persists, call the supplier help line.

Microcode bug.

59

WORM
medium —
integrity check
failed

W

The tape drive has detected an
inconsistency during the WORM
medium integrity checks. Someone may
have tampered with the cartridge.

Someone has
tampered with the
WORM medium.

Scalar i500 User’s Guide

539

Appendix B TapeAlert Flag Descriptions

No.

Flag

Severity

60

WORM
medium —
overwrite
attempted

W

Recommended Application Client
Message
An attempt had been made to overwrite
user data on a WORM medium:
1 If a WORM medium was used
inadvertently, replace it with a
normal data medium.

Probable Cause
The application
software does not
recognize the
medium as WORM.

2 If a WORM medium was used
intentionally:
a) Check that the software
application is compatible with the
WORM medium format you are
using.
b) Check that the medium is barcoded correctly for WORM.
61 –
64

Reserved

* Media Recognition System (MRS) is a method where pre-defined stripes are placed at the beginning of the
media to identify the media. The MRS stripes are read to determine if the media is of data-grade. Data-grade
media should be used in SCSI streaming devices since it is of the required quality and consistency to be used
to store data (i.e., audio/video grade media should not be used).

Scalar i500 User’s Guide

540

Glossary

1U, 2U, 3U, etc. Racks manufactured for mounting computer hardware

often define vertical space as “units.” The components that are
mounted in the racks are defined by how many units of rack
space they require. For example, the height of a unit in a rack is
1.75 inches. If a component is 5.25 inches in thickness, the
component is said to be a 3U component.

A

Arbitrated loop A Fibre Channel configuration that attaches multiple

communicating ports in a loop. Two or more ports can
interconnect, but only two ports can communicate
simultaneously.

Arbitration The submission of a request to gain access to an arbitrated

loop by a device, so that it can transmit data in the loop.

Availability A RAS attribute that refers to the accessibility of a system

resource in a timely manner; for example, the measurement of a
system’s uptime.

B

Barcode A printed array of varied rectangular bars and spaces that can

be scanned and read for object identification.

Bus

Scalar i500 User’s Guide

A transmission channel through which electrical signals are
carried from one device to another device.

541

Glossary

C

CAN (Controller Area Network) A serial bus network of microcontrollers

that connects devices, sensors and actuators in a system or subsystem for real-time control applications. There is no addressing
scheme used in controller area networks, as in the sense of
conventional addressing in networks (such as Ethernet). Rather,
messages are broadcast to all the nodes in the network using an
identifier unique to the network.

Cartridge A container that is a protective housing for storage media,

such as cartridges for tapes or optical disks.

Channel zoning A method of subdividing a storage area network into

disjoint zones on a per-channel basis in order to enhance security
and qualify access.

Cleaning tape / cleaning cartridge A tape used to clean recording heads

and reading heads on a tape drive.

Cleaning slot The physical home where a cleaning tape or cartridge

resides.

CLI (Command Line Interface) A method of interfacing with a file system

in which the user types commands, using a specific command
syntax, from a command line.

COD (Capacity on Demand) A library feature that allows users to have a

large physical library, but only be licensed to use a subset of its
total capacity. Users pay only for what they are currently using.
License upgrades enable more capacity without causing a system
interruption.

Compact flash A card on the LCB that stores information about a

library’s contents and configuration.

Connectivity The method by which hardware devices or software

communicate with other hardware or software.

Control module The first module of the library. It consists of an operator

panel touch screen, library control blade (LCB), storage, tape
drives, power supplies, I/E station.

Control path The connection between a partition and host application.

The control path connection is made through a designated tape
drive. Only one tape drive can be selected as the control path per
partition.

Controller The PCB or system that translates computer data and

commands into a form suitable for use by the storage disks.

Scalar i500 User’s Guide

542

Glossary

CRU (Customer Replaceable Unit) The smallest hardware component

that can be replaced at a customer installation by a customer.

D

Default A value or setting that is selected by the hardware or software

unless specified otherwise by the user.

DHCP (Dynamic Host Configuration Protocol) A protocol for assigning

dynamic IP addresses to devices on a network. DHCP supports a
mix of static and dynamic IP addresses.

Directory A file that contains a list of other files. Directory is short for

directory file.

Drivers Software programs that enable a computer to communicate with

hard drives, CD ROM drives, printers, and other peripherals.
Drivers are stored on a hard disk and loaded into memory at boot
up.

E

Element ID - Logical An address used by a library to locate and track

library component. The address is specified in programming
logic rather than on the physical location of a component within a
library. When a logical library is used, the logical element ID
masks the physical element ID.

Element ID - Physical An address used by a library to locate and track

library component. The address is based on the physical location
of a component within a library. Applications expect to see
resources at specific IDs.

Ethernet A type of local area network designed to transport data at rates

up to 10 million bits per second. Other software, such as TCP/IP
runs on top of Ethernet to provide high-level networking services
to applications.

Event

A condition that matches a numbered, predefined set of
circumstances.

Event log A list of all predefined events logged by library and software

management tools.

Expansion Module An optional module of the library. It provides

additional storage, tape drive capacity, power, and optional I/E
stations. The module lacks an operator panel touch screen and
LCB.

Scalar i500 User’s Guide

543

Glossary

F

F_Port Fabric Port. A port on a fabric switch to which N_Ports may be

directly connected. The F_Port is not capable of communicating
with FC-AL protocol.

FC (Fibre Channel) A high speed data transfer architecture. Using optical

fibre to connect devices, Fibre Channel communications are serial
communications that occur at full duplex and achieve data
transfer rates of 200 MBps.

FC-AL (Fibre Channel Arbitrated Loop) A form of Fibre Channel network

in which up to 126 nodes are connected in a loop topology. See
also Arbitrated loop.

FC-AL Device A device that employs Fibre Channel-Arbitrated Loop and

consists of one or more NL_Ports.

Fiber

A thin filament of glass. An optical waveguide consisting of a
core and a cladding which is capable of carrying information in
the form of light. Fiber is also a general term used to cover all
physical media types supported by Fibre Channel, such as optical
fiber, twisted pair, and coaxial cable.

Fiducial In a library storage context, fiducials may be “fiducial labels” or

“fiducial tabs,” allowing reliable identification of cartridge
magazines and drive sleds, including both location and media
domain information. In the Scalar i500 tape library, a “fiducial
tab” refers to the plastic locator tabs which are installed on the
media storage columns. The robot determines the location of
these tabs to identify media storage locations. A “fiducial label”
refers to the barcode label on cartridge magazines or drive sleds
which identify magazine or drive sled type.

Firewall A set of security tools designed to separate an internal network

from the public Internet in order to keep unauthorized users out
of a restricted network. Firewalls are the primary line of security
defense for businesses.

FL_Port Fabric Loop Port. An F_Port that is capable of supporting an

attached Fibre Channel Arbitrated Loop. An FL_Port on a loop
will have the AL_PA hex’00’ giving the fabric the highest priority
access to the loop. N_Ports or NL_Ports can attach to it in an
Arbitrated Loop topology and are capable of communicating
with FC-AL protocol.

FMR (Field Microcode Replacment) tape See FUP (Firmware Upgrade) tape.

Scalar i500 User’s Guide

544

Glossary

FRU (Field Replaceable Unit) The smallest hardware component that can

be replaced at a customer installation by a certified field service
representative.

G

Gb E or GigE (Gigabit Ethernet) A transport protocol used for

transmitting data across traditional LANs. GigE is an enhanced
version of the Ethernet protocol that has been used for many
years as the underlying transport technology in IP networks.

GUI (Graphical User Interface) A computer environment that provides a

visual view of a system by incorporating windows, icons, menus,
and a pointing device. Also referred to as a Windows, Icons,
Mouse, and Pointers (WIMP) interface.

H

HAT (Host Access Table) The HP FC Storage Networking drive saves
current and previously logged-in host information in a Host
Access Table (HAT). An entry is a combination of a host’s
WWPN and the drive’s FC port to which it is connected. Host
information is stored and maintained in the HAT until filled up,
in which case the oldest unused entry is freed to allow a new host
to get registered in the HAT.
HDD (High Density Drive) A drive that contains increased storage

capacity of bits and/or tracks per square inch.

Home position Accessor axes positioned at 0 vertical and 0 horizontal,

that serve as the point of reference for the position of other
library components. Home position is used as a basis for
calibration.

Host

In general, a host is a computer or program that contains data
and provides services to other computers or devices. In Fibre
Channel terms, a host is a computer that initiates contact with
storage devices.

Hot swappable The ability to replace a defective component while the

system continues to function normally.

HTTP (Hypertext Transfer Protocol) The communication rules by which a

Web browser (client) and a server delivering Web pages
exchange information.

I

I/E (Import/Export or Insert/Eject) The movement of data or hardware in

and out of processing and storage systems.

Scalar i500 User’s Guide

545

Glossary

I/E slot A bin that contains a single piece of media in the I/E station.

A door on the front of the library that contains tape
magazines, into which cartridges to be imported are placed
manually or cartridges to be exported are placed by the picker.

I/E station

Interoperability The capability of two or more hardware devices or two

or more software routines to work together.

IP (Internet Protocol) A protocol that specifies the formats of packets and

addresses. Addresses are formulated as four groups of 2 or 3
digit numbers separated by periods, such as 255.255.255.255.

K

Kernel The heart of the UNIX operating system. The kernel is the part of

the operating system that allocates resources and controls
processes. The design strategy has been to keep the kernel as
small as possible and to put the rest of the UNIX functionality
into separately compiled and executed programs.

L

L_Port Loop Port. It only has the capability to communicate over FC-AL

hubs and through FL_Ports.

LED (Light Emitting Diode) The mode of data transmission for multimode

cables with short wave optical transceivers. Single-mode cables,
by comparison, use high powered, long wave lasers.

Library A large-scale tape device with robotics that can house multiple

tape drives and a significant amount of tape cartridges.

Library Control Module See Control module.
License key An absolute value that can only increase a licensed feature.

For example, a license key can be applied to the library to enable
unlicensed slots.

Logical library See Partition.
Loop

With this Fibre Channel option, the port operates with attached
loop-capable devices. If a point-to-point device is attached, the
appliance is not able to communicate with it.

Loop ID A unique 7-bit value from 0 to 126 that represents the 127 valid

AL_PAs (physical addresses) on a loop.

LTO (Linear Tape Open) A family of magnetic tape media that are “open”

in the sense of not being owned by a single proprietor. LTO
comes in two formats, Accelis and Ultrium. Accelis is the fast

Scalar i500 User’s Guide

546

Glossary

access implementation, while Ultrium is the high capacity
implementation.
LUN (Logical Unit Number) A unique identifier used on a SCSI bus to

distinguish between devices that share the same bus. A LUN can
be an end user, a file, or an application. In storage technology, a
single large storage device might be divided into smaller pieces,
either to make the vast storage space more manageable or
because the storage space is dedicated to different servers, drives,
or applications. When the storage space is divided into smaller
parts, each part is configured with its own SCSI unique identifier,
or LUN.

M

Magazine A container for removable media storage used in tape

libraries.

Media

A material that stores data, such as tapes in cartridges or optical
disks.

Media changer device A SCSI term referring to a tape library or a

partition, including the robot that services it.

Media ID A barcode number attached to a specific piece of media.
Media type A format/size of media, for example, LTO.
Medium See Media.
Mixed media The ability of a library to simultaneously support multiple

types of storage media.

N

N_Port Node Port. It only has the capability to communicate through an

F-Port. It is a port on a computer, disk drive, and so on, through
which the device does its Fibre Channel communication as a
direct fabric-attached port for use with the point-to-point or
fabric topology. It is identified by a World Wide Name.

NL_Port Node Loop Port. It has the capability to communicate over both

FC-AL hubs and through F_Ports.

O

Online A status for a component that indicates it is active and available

for use.

Operator Intervention Message See RAS ticket.

Scalar i500 User’s Guide

547

Glossary

OS (Operating System) A control program for a computer that allocates

computer resources, schedules tasks, and provides the user with
a way to access the resources.

P

Partition An abstraction of an underlying physical library that may

present a different personality, capacity, or both to a host. It is a
representation of real physical elements, combined to create a
grouping that is different from the physical library. Also a logical
portion of the physical library that is viewed by the host as if it is
a complete library. Partitions present the appearance of multiple,
separate libraries for purposes of file management, access by
multiple users, or dedication to one or more host application.

Pathname A list of directories separated by slashes (/) and ending with

the name of a directory or nondirectory file. A pathname is used
to trace a path through the file structure to locate or identify a
file.

Picker

The robotic hand that handles cartridges.
A Fibre Channel topology that consists of a dedicated
connection between two devices: a sending device and a
receiving device.

Point to Point

R

Rackmount An industry standard communication and computer

equipment rack cabinet.

RAS (Reliability, Availability, and Serviceability) Three key attributes of

computing system quality design. See Reliability, Availability, and
Serviceability. An infrastructure to support serviceability in order
to identify, diagnose, and fix problems within the system. This
approach is designed to address the ability of service personnel
and customers to diagnose and resolve problems identified
within the system. Additionally, configuration is addressed to
support detection of hardware configuration compatibility issues
and persistence across FRUs.

RAS ticket A ticket that alerts service personnel and customers of an

issue with the library. RAS tickets identify which library
components are most likely causing the issue. When possible, a
RAS ticket provides instructions for resolving the issue.

Reliability A RAS attribute that is designed to prevent failure of a storage

solution. See also RAS.

Scalar i500 User’s Guide

548

Glossary

S

SAM (SCSI Architecture Model) An ANSI standard that defines the

generic requirements and overall framework in which other SCSI
standards are defined. New generations of this standard are
identified by a numeric suffix; for example, the second
generation standard is SAM2.

SAN (Storage Area Network) A dedicated network that connects storage

devices and servers in a pool, providing consolidated storage and
storage management. Storage interconnects between many
initiators and target devices. The SAN allows for sharing
resources (target devices) among multiple servers (initiators).

SCSI (Small Computer System Interface) A set of standards for a high-

speed, parallel interface that connects processing devices to
peripheral devices, such as storage subsystems. The acronym is
pronounced “scuzzy.”

SCSI ID (Small Computer Systems Interface Address) An address on a

SCSI BUS. Typically there are 16 addresses on a single channel
SCSI BUS.

Server A powerful, centralized computer (or program) designed to

provide information to clients (smaller computers or programs)
upon request.

Serviceability A RAS attribute that refers to a component that is

designed to accurately diagnose and report failures, as well as
minimize downtime in a storage solution. See also RAS.

Setup wizard A tool for initially configuring the library. It appears the

first time the user starts the library. However, it can be used to
modify configurable items anytime after the initial configuration.

Sled

See UDS.

SMI-S (Storage Management Initiative Specification) An industry

standard SMI-S application programming interface (API)
developed by SNIA that facilitates the management of multivendor devices in a storage area networks (SANs) environment.

Snapshot A rapid, point-in-time image of a volume created initially on

the same disk as the original by duplicating metadata rather than
copying the full data set. Snapshots are often used to protect
against data corruption (viruses, etc.) or to create test or preproduction environments. Snapshots are also often used as a first
step for creating non-disruptive point-in-time backups, and for
copying datasets to a second disk to create a full duplicate copy
of the volume. Snapshots are created on disk, and in the same

Scalar i500 User’s Guide

549

Glossary

format as the original data. Snapshots are also referred to as
point-in-time copies and as shadow copies.
SNMP (Simple Network Management Protocol) The protocol governing

network management and the monitoring of network devices
and their functions. Similar in function to SAM, except SNMP
governs LAN, whereas SAM governs SAN.

SSL (Secure Sockets Layer) A protocol that provides encrypted

communications on the Internet. SSL is layered beneath
application protocols such as HTTP, SMTP, Telnet, FTP, Gopher,
and NNTP and is layered above the connection protocol TCP/IP.

Storage device An appliance containing data that can be accessed, added

to, changed, or deleted by the user. The storage media types
include tapes and optical disks. A storage device can be a single
disk drive, or constitute thousands of tapes in a large tape library.

Storage slot The physical home where a data cartridge resides.
Subsystem status A feature that provides predictive alerts, warning of

any loss of connectivity or device failure using local or remote
alerts. Subsystem status allows administrators to correct faults
before they affect backup or other data transfer operations.

T

Tape drive A device that spins disks and tapes while it reads and writes

data in storage.

TCP/IP (Transmission Control Protocol/Internet Protocol) The

communications protocol used by the Internet. It runs on top of
Ethernet to provide high-level networking services to
applications.

Topology The logical and/or physical arrangement of stations on a

network.

Trap

U

An SNMP alert that is sent when predefined conditions are met.
For example, an error trap tests for an error condition and
provides a recovery routine.

UDS (Universal Drive Sled) The hardware that houses Fibre Channel and

SCSI tape drives in a module.

User ID An alphanumeric value that the password database associates

with a login name. Also, UID.

Scalar i500 User’s Guide

550

Glossary

UTC (Coordinated Universal Time) The world-wide standard for time,

commonly considered to be the equivalent of “Greenwich Mean
Time” and “Zulu time.” For all of these time standards, zero (0)
hours is midnight in Greenwich England, which lies on the zero
longitudinal meridian. The sequence of the letters in the acronym
is a compromise between the English and French terms (Temps
Universel Coordonné).

W

WORM (Write Once, Read Many) A common type of data storage

medium, in which data can be read and reread, but not altered,
after it has been recorded.

WWNN (World Wide Node Name) A unique number assigned by a

recognized naming authority. The World Wide name is integral
to Fibre Channel operations.

WWPN (World Wide Port Name) The WWPN is a 64-bit, hard-coded

address for each port on an FC-connected device. It is used to
identify available SAN devices at end points.

X

X-axis, X-position The horizontal position of the library’s robotic arm.

Y

Y-axis, Y-position The vertical position of the library’s robotic arm.

Scalar i500 User’s Guide

551



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : Technical Publications (de)
Create Date                     : 2014:01:29 09:31:02Z
Modify Date                     : 2014:01:29 14:08:20-07:00
Subject                         : Online Documentation Series
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Description                     : Online Documentation Series
Title                           : Scalar i500 User’s Guide
Creator                         : Technical Publications (de)
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : FrameMaker 11.0.1
Metadata Date                   : 2014:01:29 14:08:20-07:00
Document ID                     : uuid:a22b1263-01c2-4d93-b471-0a6c85e388ae
Instance ID                     : uuid:ed8dd413-5de2-4cdd-a7da-ac46d37e227a
Page Mode                       : UseOutlines
Page Count                      : 570
EXIF Metadata provided by EXIF.tools

Navigation menu