R tron SIDENF800 iDEN Add-On Filter Box User Manual

R-tron Inc. iDEN Add-On Filter Box

Contents

Part 1

Download: R tron SIDENF800 iDEN Add-On Filter Box User Manual
Mirror Download [FCC.gov]R tron SIDENF800 iDEN Add-On Filter Box User Manual
Document ID782347
Application IDjtp5ajjN3+a1Or9Xgej7NQ==
Document DescriptionPart 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize320.24kB (4002969 bits)
Date Submitted2007-04-19 00:00:00
Date Available2007-04-20 00:00:00
Creation Date2007-04-03 21:16:24
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2007-04-03 21:16:30
Document Titleuntitled

iDEN Add-On Filter Box
User’s Manual
R-tron Inc.
User’s Manual
-1-
This document describes the specifications, installation and operation of iDEN Add-On Filter Box.
Hardware and software mentioned in this document are subject to continuous development and
improvement. Consequently, there may be minor discrepancies between the information in the
document and the performance and design of the product. Specifications, dimensions and other
statements mentioned in this document are subject to change without notice.
R-tron Inc. 6402 College Boulevard Overland Park, KS 66211
Phone: +1-913-344-9977, 1-888-31R-TRON Fax: +1-913-344-9988 Internet: www.r-tron.com
R-tron is registered trademarks of R-tron Inc. Other products and company names mentioned herein this
manual might be trade marks or trade names of their respective owners.
This document or parts of it may not be reproduced without the written permission of R-tron Inc.
Infringements will be prosecuted. All rights reserved
Copyright © R-tron Inc. 2000-2007
User’s Manual
-2-
iDEN Add-On Filter Box
Contents
Abbreviations .......................................................................................................................5
1.
Introduction ...........................................................................................................6
2.
Description.............................................................................................................8
2.1
System Specifications ....................................................................................................... 8
2.1.1. Electrical Specifications.......................................................................................... 8
2.1.2. Mechanical Specifications ...................................................................................... 8
2.2
Sub Unit Overview........................................................................................................... 10
2.2.1. Block Diagram .......................................................................................................11
2.2.2. Filter Module......................................................................................................... 12
2.2.3. Duplexer ............................................................................................................... 13
2.2.4. MCU (Main Control Unit) ...................................................................................... 14
2.2.5. Power Supply ....................................................................................................... 15
3.
Hardware Installation............................................................................................16
3.1
3.2
3.3
3.4
3.5
3.6
4.
Check List of Items.......................................................................................................... 16
Mounting.......................................................................................................................... 17
Grounding........................................................................................................................ 17
RF Cable Connection ...................................................................................................... 18
Bandwidth & Band Setup ................................................................................................ 19
Power Up......................................................................................................................... 21
Troubleshooting....................................................................................................22
4.1
4.2
4.3
User’s Manual
RF Connection Check ..................................................................................................... 22
Power Connection ........................................................................................................... 22
Red Light on the Alarm LED............................................................................................ 23
-3-
iDEN Add-On Filter Box
Figures
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
User’s Manual
R-tron iDEN Add-On Filter Box ................................................................................... 6
Overview: Interference Filtering................................................................................. 7
Dimension of iDEN Add-On Filter Box ......................................................................... 9
Internal View of iDEN Add-On Filter Box ................................................................... 10
Block Diagram ........................................................................................................ 11
Filter Module........................................................................................................... 12
Duplexer ................................................................................................................ 13
Main Control Unit .................................................................................................... 14
Power Supply.......................................................................................................... 15
Items.................................................................................................................. 16
Mounting ............................................................................................................ 17
Grounding ........................................................................................................... 18
Configuration: RF Cable Connection...................................................................... 18
Dip Switches for Bandwidth and Band Setup ......................................................... 19
Index Table for Bandwidth and Band Setup ........................................................... 19
Power Cord Connection ........................................................................................ 21
LEDs Off ............................................................................................................. 22
AC power cord Check........................................................................................... 23
Red Light on Alarm LED ....................................................................................... 23
-4-
iDEN Add-On Filter Box
Abbreviations
Abbreviations used in this manual, in iDEN Add-On Filter Box.
AC
ANT
CDMA
DC
GND
GUI
iDEN
LED
PSU
RF
TEMP
VSWR
User’s Manual
Alternating Current
Antenna
Code Division Multiple Access
Direct Current
Grounding
Graphic User Interface
Integrated Digital Enhanced Network
Light Emitting Diode
Power Supply Unit
Radio Frequency
Temperature
Voltage Standing Wave Ratio
-5-
iDEN Add-On Filter Box
1. Introduction
Bandwidth
Band Setup Table
Filtered
Output Port
Input Port
Dip Switch for Bandwidth & Band Setup
Screw for Grounding
AC Power Socket & Switch
Figure 1.
R-tron iDEN Add-On Filter Box
The interference within the service frequency bands is a target to be
removed because it causes the degradation of the service quality and
shrinking of the coverage.
iDEN Add-On Filter Box is the equipment for filtering off such interference
adjacent to iDEN downlink frequencies allocated at 800MHz’s and 900MHz’s
with the following features:
User’s Manual
„
7MHz or 18MHz filtering @ 800MHz’s
„
5MHz filtering @ 900MHz’s
„
Band Shifting @ 800MHz’s and 900MHz’s
„
Roll Offs: 65 dBc at 0.5 MHz outside pass-band
-6-
iDEN Add-On Filter Box
Interference
Donor Antenna
Service
Antenna
Mobile
Service
Donor
Repeater
Filtered
Output
Base Station
iDEN Add
- On Filter Box
Figure 2.
User’s Manual
Input
Overview: Interference Filtering
-7-
iDEN Add-On Filter Box
2. Description
2.1 System Specifications
2.1.1. Electrical Specifications
Parameter
Band Selection
(BW)
DL
UL
18MHz
Frequency
Selection
DL
7MHz
5MHz
Roll off
DL
Gain ripple
DL
Gain
UL
DL
Delay
UL
DL
VSWR
UL
Input
DL
Range
UL
Power supply
Operating temperature
Storage temperature
Consumption power
iDEN 800
In-band BW:18M
In-band BW:7.0M
In-band 18M
851~869MHz
850.8~868.8MHz
850.8~868.6MHz
862~869MHz
861.8~868.8MHz
861.6~868.6MHz
iDEN 900
In-band BW:5M
In-band 5M
935~940MHz
934.8~939.8MHz
934.6~939.6MHz
≤65dBc
≤65dBc
@Fedge+/@Fedge+/-500KHz
500KHz
±1.5dB (Typical)
0±1.5dB
~ -7.9 dB Max
8.0uS Max
1uS Max
1.5Max
1.5 Max
-10dBm Max
-10dBm Max
By Pass
By Pass
85V~264V, 50/60Hz typ.
*-10℃ ~ 50℃
-20℃~ 60℃
≤20W
2.1.2. Mechanical Specifications
Parameter
RF connectors
Size
Weight
User’s Manual
Specification
N-female x 2, SMA-female x 2
4.52 X14.96 X 12.2(Inch),
115 X 380 X 310(mm)
6.4kg (14.1lbs)
-8-
MAKER : R-tron lnc.
E258109
I.T.E
31CY
MODEL NO. : RSP-AIT-R001
ELECTRICAL RATING : 100-240V ~ , 50/60Hz, 1A
COMPLIES WITH PART 24, FCC RULES.
FCC REG. NO. : STESPAITR001
SERIAL NO. / DATE :
MADE IN KOREA
iDEN Add-On Filter Box
800M BS
18MHz
7MHz
18B FS 1
851~869MHz
851~869MHz
850.8~868.8MHz
850.6~868.6MHz
7B FS 2
862~869MHz
862~869MHz
861.8~868.8MHz
861.6~868.6MHz
900M FS 3
935~940MHz
935~940MHz
934.8~939.8MHz
934.6~939.6MHz
BRACKET
800M BS
OUTPUT MON.
Filtered
OUTPUT
AC IN
100-240V ~
18B FS 1
INPUT MON.
INPUT
7B FS 2
900M FS 3
ALARM
DANGER
RISK OF ELECTRIC SHOCK
Figure 3.
User’s Manual
Dimension of iDEN Add-On Filter Box
-9-
iDEN Add-On Filter Box
2.2 Sub Unit Overview
iDEN Add-On Filter Box is composed of the following sub units:
„
Filter Module
„
Duplexer
„
Main Control Unit (MCU)
„
Power Supply Unit (PSU)
„
EMI Filter
MCU
Filter Module
Duplexer
PSU
Figure 4.
User’s Manual
Internal View of iDEN Add-On Filter Box
-10-
iDEN Add-On Filter Box
2.2.1. Block Diagram
The following, Figure 5, explains how the unit filters signals.
FB iDEN
SAW Filter with Programmable options
851~869 / 850.8~868.8 / 850.6~868.6 MHz
with -65dBc@±500KHz
18MHz
Donor
antenna
Service
antenna
7MHz
Filter 851~869MHz
Filter 806~824MHz
iDEN
Repeater
Filter
SAW Filter with Programmable options
851~869 / 850.8~868.8 / 850.6~868.6 MHz
with -65dBc@±500KHz
Filter 806~869MHz
LO1
Filter 896~940MHz
LO2
Filter
Filter
PLL
Filter
Filter 896~901MHz
Filter
Filter 935~940MHz
Filter
SAW Filter with Programmable options
935~940 / 934.8~939.8 / 934.6~939.6 MHz
with -65dBc@±500KHz
Figure 5.
User’s Manual
Block Diagram
-11-
iDEN Add-On Filter Box
2.2.2. Filter Module
The Filter Module is basically a complex band-pass filter that sharply filters
out unwanted noise.
Output Port
Input Port
Figure 6.
User’s Manual
Filter Module
-12-
iDEN Add-On Filter Box
2.2.3. Duplexer
A duplexer is a device that combines two or more signals onto a common
channel or medium to increase its transmission efficiency.
800/900MHz
Input
900MHz Input
Input CPL
-10dB
800MHz Input
Figure 7.
User’s Manual
Output CPL
-10dB
800/900MHz
Output
800MHz Output
900MHz Output
Duplexer
-13-
iDEN Add-On Filter Box
2.2.4. MCU (Main Control Unit)
MCU is the control unit of iDEN Add-On Filter Box. It controls and monitors
operational parameters. It also generates alarms, an event log and many
other functions of the iDEN Add-On Filter Box.
USB1A_J1
MOL4
LED1
MOL1
LED2
LED3
MOL3
Figure 8.
MOL2
Main Control Unit
Pin Map
Port
Connected to
USB1A_J1
Local OMT
MOL1
MCU Vcc(+6V)
MOL2
iDEN 800 PLL,B/S,OUT DET
MOL3
iDEN 900 PLL,B/S,OUT DET
MOL4
Dip Switch Control
LED
LED
User’s Manual
LED1
Red light indicates MCU power “on”
LED2
Green light indicates 800 PLL Lock
LED3
Green light indicates 900 PLL Lock
-14-
iDEN Add-On Filter Box
2.2.5. Power Supply
The Power Supply Unit (PSU) supplies a steady DC power to iDEN Add-On
Filter Box by drawing power from the general in-wall AC outlets
Figure 9.
Power Supply
Specifications
Item
Operating Temp
Environmental
Storage Temp
-20℃~70℃
Humidity
20%~90%RH
Cooling method
Natural air
Voltage
User’s Manual
Specifications
-10℃~60℃
AC85~264V
Current
4.2A Max / 12Vdc
Frequency
Leakage Current
47~440Hz max (50~60Hz typ)
0.5mA max.@110V AC
-15-

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Page Count                      : 15
PDF Version                     : 1.6
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:1d7ea9d8-e9ec-4a93-b98f-e5967442d6d5
Modify Date                     : 2007:04:03 21:16:30+09:00
Create Date                     : 2007:04:03 21:16:24+09:00
Metadata Date                   : 2007:04:03 21:16:30+09:00
Document ID                     : uuid:508bc630-da59-4c77-a876-8ef146a734a0
Format                          : application/pdf
Title                           : untitled
Producer                        : Acrobat Distiller 6.0.1 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: STESIDENF800

Navigation menu