RAE Systems PRR-1 Dosimeter Reader User Manual SU3PRR 1
RAE Systems, Inc Dosimeter Reader SU3PRR 1
SU3PRR-1_user manual
Dosimeter Reader User’s Guide Rev. A April 2013 P/N R04-0310-000 © Copyright 2013 RAE Systems, Inc. Dosimeter Reader User’sGuide Contents 1 Read before Operating ........................................... 4 2 Warnings................................................................. 4 3 Regulatory Compliance .......................................... 4 4Dosimeter Reader Features ..................................... 7 5 General Information ............................................... 8 6 Operation .............................................................. 10 6.1 Powered on/off .............................................. 10 6.2 Build connection with DoseRAE Pro............ 10 6.3 Relay data between DoseRAE Pro and ProRAE Dosimeter.............................................. 12 7. Specifications* .................................................... 13 8 Technical Support ................................................. 15 9 RAE Systems Contacts......................................... 16 Dosimeter Reader User’sGuide 1Read before Operating This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining, or servicing this product. The product will perform as designed only if it is used, maintained, and serviced in accordance with the manufacturer’s instructions. 2Warnings For safety reasons, this equipment must be operated and serviced by qualified personnel only. Read and understand the user manual completely before operating or servicing. Dosimeter Reader User’sGuide 3 Regulatory Compliance FCC Part 15 Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Information for User Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user Dosimeter Reader User’sGuide can reasonably be expected to have the capability to access information in that form. Dosimeter Reader User’sGuide 4 Dosimeter Reader Features Dosimeter ReaderUser’sGuide 5General Information The Dosimeter Reader PRR-1 is a specially designed supporting electronic device for DoseRAE Pro dosimeters.It communicates with the dosimeters in pass-by and short range data exchanges in a wireless manner, forconfiguring, activating, and diagnosing the dosimeters via the PC-installedsoftware, ProRAE Dosimeter V2.00 or higher versions. The PRR-1 has three visual indicators for showing its operation statusesand a USB port for enablingdata exchanges with PC via a USB cable. In addition, it also has bolt-head receiving and slip-resistant features for being mounted on wall or reducing slippery when placed on a desk surface. Dosimeter ReaderUser’sGuide Key Features · NFC (13.56MHz) contactless smart reader · Multi-functions in one, including configuration and diagnosis of DoseRAE Pro dosimeters · User and product identification or authentication · Three LED lights indicating whether the readeris powered on, ready for and currently in data communications, respectively · Power supply by PC via a USB cable · Compact size(140mm×100 mm×30mm, 5.5”×4.0”×1.2”) · Lightweight (120 g or 4.2 oz) · Comply with FCC part 15 and EN 300 330-2 V1.5.1, EN 301 489-1 V1.9.2 and EN 301 489-3 V1.4.1, CE R&TTE Directive 1999/5/EC (Article 3.1b and 3.2) Standard Kit · Dosimeter Reader unit · USB cable · User’ Guide Dosimeter ReaderUser’sGuide 6Operation When operating, the Dosimeter Reader PRR-1 links a DoseRAE Pro dosimeter andProRAE Dosimeter to enable the software to: · Read out and set parameters from and for the dosimeter · Upgrade firmware for the dosimeter · Identify user ID or instrument ID · Diagnose the dosimeter · Download data from the dosimeter · Clear or reset dose history for the dosimeter. 6.1 Powered on/off Dosimeter Reader PRR-1 is powered by a PC through a proper USB cable (e.g., the one provided with the standard kit) with one end inserted into the square USB port of the reader and the other endinto a standard (rectangular)USB port of the PC. When connected to a PC, the “Power” LED (red) is on, indicating the reader is power on, andvice versa. 6.2Build connection with DoseRAEPro When a DoseRAE Pro unit is loaded onthe top surface of the Dosimeter Reader PRR-1 (preferable, onacenter portion of the top surface where the wireless symbol is 10 Dosimeter ReaderUser’sGuide marked, referring to the following image),the“Access” LED (green) is on, indicating that the reader has sensed,and built a connection with,the DoseRAE Pro dosimeter. 11 Dosimeter ReaderUser’sGuide 6.3 Relay data between DoseRAE Pro and ProRAE Dosimeter When there are data exchanges between the dosimeter and the software, the “Status” LED flashes in green frequently. 12 Dosimeter ReaderUser’sGuide 7. Specifications* Data Transmission Near Field Communication (NFC, 13.56MHz) Transmission Distance < 3cm Response Time Operation status Indicators < 3s Three LEDs: Power - the reader is powered on; Status - data exchanges between the DoseRAE Pro dosimeter and ProRAE Dosimeter software; Access - the reader has sensed and built a connection with the DoseRAE Pro dosimeter USB Communicati ons with PC Management Software ProRAE Dosimeter V2.00 or higher versions Power supply PC via a USB cable; Voltage: 5VDC; Power consumption < 600 mW 13 Dosimeter ReaderUser’sGuide Dimensions 140mm×100mm×30mm (5.5”×4.0”×1.2”) Weight Environmental 120g (4.2 oz) Operating Temperature: -20° to +50°C Storage Temperature: -30° to +85°C Humidity: < 95%RH (noncondensing) Certification FCC: Part 15 CE: EN 300 330-2 V1.5.1, EN 301489-1 V1.9.2 and EN 301 489-3 V1.4.1, the R&TTE Directive 1999/5/EC (Article 3.1b and 3.2) * Specifications are subject to change 14 Dosimeter ReaderUser’sGuide 8 Technical Support To contact RAE Systems Technical Support Team: Monday through Friday, 7:00AM to 5:00PM Pacific (US) Time Phone (toll-free): +1 888-723-4800 Phone: +1 408-952-8461 Email: tech@raesystems.com Critical after-hours support is available: +1 408-952-8200 select option 9 15 Dosimeter ReaderUser’sGuide 9 RAE Systems Contacts RAE Systems World Headquarters 3775 N. First St. San Jose, CA 95134-1708 USA Phone: +1 408.952.8200 Fax: +1 408.952.8480 E-mail: customerserv@raesystems.com Web Site: www.raesystems.com RAE Systems Europe ApS Kirstinehøj 23 A DK-2770 Kastrup Denmark Phone: +45 86 52 51 55 Fax: +45 86 52 51 77 orders@raeeurope.com sales@raeeurope.com service@raeeurope.com Web: www.raesystems.eu RAE Systems UK Ltd D5 Culham Innovation Centre Culham Science Centre Abingdon, Oxon OX14 3DB United Kingdom Phone: +44 1865408368 Fax: +44 1235531119 16 Dosimeter ReaderUser’sGuide Mobile: +44 7841362693 Email: raeuk@raeeurope.com RAE Systems France 336, rue de la fée des eaux 69390 Vernaison France Phone: +33 4 78 46 16 65 Fax: +33 4 78 46 25 98 Email: info-france@raeeurope.com Web: www.raesystems.fr RAE BeNeLux BV Hoofdweg 34C 2908 LC Capelle a/d Ijssel Phone: +31 10 4426149 Fax: +31 10 4426148 Email: info@rae.nl Web: www.rae.nl RAE Systems Spain, s.l. Av. Remolar, 31 08820 El Prat de Llobregat Spain Phone: +34 933 788 352 Fax: +34 933 788 353 Mobile: +34 687 491 106 17 Dosimeter ReaderUser’sGuide Email: mdelgado@raespain.com Web: www.raespain.com RAE Middle East LOB 7, Ground Floor, Office 19, Jebel Ali Free Zone Dubai, United Arab Emirates Phone: +971.4.887.5562 Email: mesales@raesystems.com RAE Systems (Hong Kong) Ltd. Room 8, 6/F, Hong Leong Plaza 33 Lok Yip Road Fanling, N.T, Hong Kong Phone: +852.2669.0828 Fax: +852.2669.0803 Email: hksales@raesystems.com Nihon RAE Systems Co., Ltd. Marunouchi Nakadori BLDG 6F-617-B, 2-3, Marunouchi 2-Chome, Chiyoda-ku, Tokyo, Japan Phone: 81-3-6269-9646 Fax: 81-3-6269-9647 Email: jpsales@raesystems.com RAE Systems Korea #1010, DaeMyungAnsVill First, 18 Dosimeter ReaderUser’sGuide Sang-Dong 412-2, Wonmi-Gu, Bucheon, Kyungki-Do, Korea Phone: 82-32-328-7123 Fax: 82-32-328-7127 Email: krsales@raesystems.com 19 RAE Systems World Headquarters 3775 N. First St. San Jose, CA 95134-1708 USA Phone: 408.952.8200 Fax: 408.952.8480 Email:customerserv@raesystems.com Website:www.raesystems.com Rev. A April 2013 P/N R04-0310-000
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 20 Modify Date : 2013:05:24 14:52:56+08:00 Create Date : 2013:05:24 14:52:56+08:00 Title : Microsoft Word - R04-0310-000_RevA_Dosimeter_Reader_PRR-1_Manual_20130522.docx Author : yzchen Creator : R04-0310-000_RevA_Dosimeter_Reader_PRR-1_Manual_20130522.docx - Producer : Ultra PDFEXIF Metadata provided by EXIF.tools