REnex Technology PT108-0001001 2442MHz Wireless Modem User Manual

REnex Technology Limited 2442MHz Wireless Modem

User Manual

 - iii -      FCC Declaration of Conformity  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: i) this device may not cause harmful interference, and ii) this device must accept any interference received including interference that may cause undesired operation.   NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. •  Consult the dealer or an experienced radio/TV technician for help.   RS-232 DB9 shielded cable with ferrite must be used with this unit to ensure compliance with the Class B FCC limits.                  CAUTION: The model number PT-108U has maximum transmitted output power of 0.5 Watt.  It is recommended that the transmit antenna be kept at least 20 cm away from nearby persons to satisfy FCC RF exposure requirements. The antenna and transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
   7   3.1  Setting up Connections PT-108U modems are supposed to work properly when they are delivered from REnex.  Hence, the only thing users need to do is to make the appropriate application interface connections and power up.  The master and slave(s) shall communicate properly.  The pin definitions of the application interface are listed in Table 2.  Users may connect the RS-232 pins to their equipment according to their practical situations.  For any enquiry, please contact REnex for further information.  3.2 Checking the Link After finishing the physical connection setup mentioned above, PT-108U should be ready.  If the performance of the communication links is not satisfied or any linking problem is found, the following steps may help you locate the problem.  1.  Install DB-9 connectors to the PT-108U modems as described in Section 2.4. 2.  Connect each modem to a serial port of a PC. 3.  Start a terminal program such as Hyper Terminal (http://www.hilgraeve.com, it may be found in Microsoft Windows OS) for each serial port.  Make sure the baud rate and data format settings agree with those of PT-108U. 4.  Type characters to the master’s terminal should appear at that of the slave’s and vice versa. 5.  The TX LED should flash during transmitting data to the RF link. 6.  The RX LED should flash during receiving data from the RF link. 7.  Adjust the modem separations and the antenna direction to locate positions with the best performance.             3. Setup PT-108U NOTE 2: PT-108U is highly sensitive to obstacles in its communication path.Make sure the communicating modems are in line-of-sight.  Otherwise, theperformance would drop significantly.  NOTE 3: Antenna height is a critical factor.  Try to put the antenna to aposition as high as possible.

Navigation menu