RF Controls ITCS-A-405 RF ID Reader User Manual User Guide

RF Controls, LLC RF ID Reader User Guide

User&InstallManualBESPAUserGuideA-405Ver1_2 0601.pdf

Download: RF Controls ITCS-A-405 RF ID Reader User Manual User Guide
Mirror Download [FCC.gov]RF Controls ITCS-A-405 RF ID Reader User Manual User Guide
Document ID3027566
Application IDeqKnGCwzatNJtgLfWcDMqA==
Document DescriptionUser&InstallManualBESPAUserGuideA-405Ver1_2 0601.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize57.62kB (720238 bits)
Date Submitted2016-06-14 00:00:00
Date Available2016-06-14 00:00:00
Creation Date2016-06-01 12:20:42
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2016-06-01 12:20:42
Document TitleUser Guide
Document CreatorMicrosoft® Word 2010
Document Author: Chris Turner

User Guide
BESPA™ (Bidirectional Electronically Steerable Phased Array)
RF Controls Intelligent Tracking and Control System (ITCS™)
ITCS-A-405 BESPA™ Antenna Models
Configured with an RFC-A-405 RFID Reader CCA
Revision History
Rev
Date
1.00- Sept 2015
1.10- Oct 2015
1.20- June 2016
Description
FAE 2013 1st Draft from A-30X Family
ACC Change to A-405
Reviewer Comment List Max Antenna Gain
© 2015 RF Controls, LLC. All rights reserved.
No part of this publication may be reproduced or used in any form, or by any
electrical or mechanical means, without permission in writing from RF Controls. This
includes electronic or mechanical means, such as photocopying, recording, or
information storage and retrieval systems. The material in this manual is subject to
change without notice.
SASL User Guide v1.10 - Part # 11400-431
October 2015
Introduction
This BESPA™ User Guide provides the basic information needed to install an individual BESPA
antenna unit containing an RFC-A-405 RFID Reader CCA. This guide is not intended to provide
instructions for installing, configuring and calibrating the RF Controls Intelligent Tracking and
Control System (ITCS™). Detailed instructions are provided in the Technical Manual (ITCS-A100-002) and Programmer’s Reference Guide (ITCS-A-100-003).
INTENDED AUDIENCE
This guide is intended for those who will install and set up the RF Controls BESPA (Bidirectional
Electronically Steerable Phased Array) unit. Before attempting to install, configure and operate this
product, you should be familiar with the following:




Windows based software installation and operation
Device communication parameters including Ethernet and serial communications
RFID reader configuration including antenna placement and RF Parameters
Electrical and RF safety procedures.
Table of Contents
-BESPA Overview ............................................................................................................................ 3
-INSTALLATION .............................................................................................................................. 5
-Mechanical Installation ................................................................................................................ 5
-Electrical Installation ................................................................................................................... 5
-SOFTWARE ................................................................................................................................... 8
-SPECIFICATIONS .......................................................................................................................... 8
-SAFETY INSTRUCTIONS
Consignes de Sécurité ..................................................................... 9
FCC NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
The BESPA products and individual BESPA components are protected by one or more US
and International Patents pending.
The “RF Controls” logo, and the words “RF Controls, Identify, Locate, Track”, “ITCS”, and
“BESPA” are registered Trademarks of RF Controls, LLC.
SASL User Guide v1.10 - Part # 11400-431
October 2015
-BESPA Overview
BESPA is a multi-protocol, multi-regional Radio Frequency Bidirectional Electronically Steerable
Phased Array unit, which is used to Identify and locate RFID tags operating in the UHF 840 – 960
MHz frequency band. A number of BESPA units may be used together with an ITCS Location
Processor to form an Intelligent Tracking and Control System (ITCS). BESPA comprises an
embedded multi-protocol, multi-regional RFID reader/writer transceiver connected to the patented
steerable phased array antenna system. BESPA is designed to be powered from Power-OverEthernet and communicates with a host computer using standard Ethernet TCP/IP and UDP
protocol. Figure 1 illustrates the version of BESPA currently available. The ITCS-A-405 contains
the RF Controls RFC-40X RFID reader CCA.

ITCS-A-405 are constructed using a Bi-directional Electronically Steerable Phased Array
(BESPA™) arranged to provide a single array with a circularly polarized gain of more than
6dBi and Linear Gains of more than 9dBi.
The particular units used in an installation will depend on the system design and determined by a
qualified applications engineer.
Figure 1 BESPA (Bidirectional Electronically Steerable Phased Array) Units
SASL User Guide v1.10 - Part # 11400-431
October 2015
INDICATOR LIGHTS
ITCS-A-405 Reader Indicator Lights
The RF Controls ITCS-A-405 RFID antenna is equipped with four status indicators located on the
top of the Radome. From left to right, these LEDs provide indication according to the following
table:
Indication
Tag Sense
Transmit
Fault
Power
Color/State
Indication
Off
Blue
Off
Yellow
Off
Red-Flashing
Off
Green
No Tags Detected
Tags Detected
RF Off
Transmit Active
OK
Error/Fault Blink Code
Power Off
Power On
Note that when the ITCS-A-405 antenna is performing power on auto-test, the indicator lights will
flash momentarily.
Figure 2 RF Controls ITCS-A-405 RFID Antenna Indicator Lights.
SASL User Guide v1.10 - Part # 11400-431
October 2015
-INSTALLATION
-Mechanical Installation
Each model of the ITCS-A-405 family of BESPA units is mounted slightly differently. BESPA units
weigh up to 15 lbs (7 kg), it is important to ensure that the structure, to which the BESPA is to be
attached, is of sufficient strength. The BESPA may be ceiling mounted, wall mounted or attached
to a suitable stand. A safety cable rated at three (3) times the hanging weight of the BESPA and
associated hardware must be secured to a separate fixture and attached to the BESPA mounting
bracket.
When mounting the BESPA as a stand-alone unit, make sure that it is mounted the with the POE+
RJ45 facing down as indicated by information in the Technical Manual. If the BESPA is one of
several and is part of an ITCS network, then orient each BESPA according to the ITCS system
installation drawings. If in doubt contact a member of our technical support team.
ITCS-A-405
The ITCS-A-405 BESPA is only mounted in a landscape orientation because the array is
symmetrical, there is no benefit to mounting the array in a portrait fashion. When mounting the
BESPA refer to Figure 4. Consult the Technical Manual, for further information. Contact a
member of our technical support team for more information.
SAFETY WARNING
The ITCS-A-405 weighs approximately 15 lbs (7kg). These units should only be installed
using suitable safety and lifting equipment. Ensure that the wall fixings or mounting
hardware is suitably rated.
AVERTISSEMENT DE SÉCURITÉ
ITCS-A-405 pèse environ 7kg. Ces unités ne doivent être installés à l'aide des
équipements de sécurité et de levage approprié. Veiller à ce que les fixations murales ou
le matériel de montage est convenablement évalués.
-Electrical Installation
POE Power Input
POE+ power input is available for the ITCS-A-405 using the RJ-45 connector as shown in Figure 4.
Connect POE+ power supply and plug it in to a suitable mains outlet and the POE+ Bias T. POE+
power, DC Input equivalent to IEEE 802.3at type 2. When using a multiport Ethernet switch the
power budget for each antenna should be +25W. Do not plug in more than the calculated number
of POE+ antennas to a multiport switch if the total Switch Ethernet power will be exceeded. Note
that the power for the POE+ bias T should be located in close proximity to the BESPA and should
be accessible to enable easy disconnection of the power to the BESPA in case of emergency or
when servicing.
SASL User Guide v1.10 - Part # 11400-431
October 2015
Ethernet
The Ethernet LAN connection uses the industry standard RJ-45 connector. A suitable Ethernet
cable fitted with an RJ-45 plug is connected to the BESPA Array Controller box as shown in Figure
4. The BESPA is factory programmed with a fixed IP address which is shown on the label adjacent
to the Ethernet connector. A Ferrite clamp must be attached to the Ethernet cable in a single loop
approximately six inches from the antenna in order to meet EMI emission requirements. Suggested
ferrite part number is Fair-Rite #0431176451 to be included in installation Kit.
Figure 4 ITCS-A-405 Power and Ethernet Connections
WARNING
The BESPA is not user serviceable. Disassembly or opening the BESPA will cause
damage to its operation, will void any warranty and may invalidate the FCC type approval
Non Ionizing Radiation
This unit incorporates a Radio Frequency Transmitter and should therefore be installed and
operated so as to avoid exposure of any persons to unsafe emissions. A minimum separation
distance of 23cm must be maintained at all times between antenna and all persons. See FCC
Radiation Exposure Statement in the Safety Instructions section of this guide.
Notice for European Installers
The Installer shall ensure that he is familiar with any restrictions of the local EU Member State on
the use of this device and ensure compliance! Examples may include: restrictions on geographic
location or only for indoor use etc.
Due to differences between ETSI and FCC frequency bands, “Phase Ranging” Techniques are not
available with the ETSI version of the BESPA.
SASL User Guide v1.10 - Part # 11400-431
October 2015
Usable Frequency Range in US and Canada
In USA and Canada this device is factory programmed to operate in ISM 902MHz – 928MHz band.
MULTIPLE BESPA UNITS CONFIGURED AS AN ITCS
Figure 5 shows how two or more ITCS-A-300 BESPA units may be connected via an Ethernet
network to an ITCS Location Processor. One Location Processor and multiple distributed BESPAs
operate collaboratively to form RF Controls’ Intelligent Tracking and Control System (ITCS™). In
this example two BESPA units have been attached to the network. Combinations of the various
model BESPA units may be mixed and matched as required to suit a particular installation. The RF
Controls Technical Manual provides details on how to install, configure and calibrate an ITCS.
The Programmers Reference Guide provides details of the Application Program Interface (API)
used by the ITCS.
Figure 5 Intelligent Tracking and Control System comprising a number of BESPA units connected via
an POE+ Ethernet Network to an ITCS Location Processor
SASL User Guide v1.10 - Part # 11400-431
October 2015
-SOFTWARE
The BESPA is provided with a basic test program on a CD, to run on a Microsoft™ Windows®
equipped Personal Computer. The program enables you to carry out a number of basic tests.
See the Technical Manual for further instruction on Software usage.
APPLICATION INTERFACE
The BESPA uses an International Standard, Application Program Interface (API) as defined in
ISO/IEC 24730-1. Further details of the API and commands are contained in the Programmer’s
Reference Guide.
-SPECIFICATIONS
ITCS-A-405
Frequency
RF Radiated Power
Regulatory Compliance
Reading/Writing
Protocols
FCC ID IC ID
Application Interface
UHF band: 860 – 940 MHz1
Adjustable 0.2W to 4Watts EiRP
FCC, CFR47 Part 15.247 EN 302 208, EN 301 489-3,
EN 301 489-1, EN55022, EN55024, EN 60950-1:2005
ISO18000-6C / EPC UHF Gen 2
EM 4122 (TTO)
WFQITCS-A-405
10717A-ITCSA405
ISO/IEC 24730-1
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Dimensions
Weight
Ethernet LAN
Power
Current and Voltage
+14 to +130°F (-10 to +55°C)
-40 to +185°F (-40 to +85ºC)
5 to 85% non-condensing
24in x 24in x 4in (60 x 60 x 10 cm)
15 lbs (7 kg)
RJ-45 Connector
POE+ DC Input IEEE 802.3at Type 2
0.7Amp at +48Vdc
Antenna
4.6 dBi Circular Polarization
10.9 dBi Linear Polarization
Gain2
The SASL uses the RFC RFC-6100XR RFID reader which will be factory set at time of shipping, to suit the
country of installation and use.
Maximum value over Operating Frequency Range as referenced to an isotropic antenna.
SASL User Guide v1.10 - Part # 11400-431
October 2015
-SAFETY INSTRUCTIONS
Consignes de Sécurité
This unit emits Radio Frequency non-ionizing radiation. The installer must ensure that the antenna
is located or pointed such that it does not create an RF field in excess of that permitted by the
Health and Safety Regulations applicable to the country of installation.
Cet appareil émet Radio Fréquence rayonnements non ionisants. L'installateur doit s'assurer que
l'antenne est située ou orientée de façon à ne pas créer un champ RF supérieure à celle permise
par le Règlement sur la santé et applicable dans le pays d' installation.
Setting RF Output Power
Enter the desired RF output power as a percentage of the maximum power into the Set Power box.
Click the set Power button. Note: the actual maximum Radiated RF Power is factory set to comply
with the radio regulations in the country of use. In the USA and Canada this is 4 Watts EiRP and
under EN 302 208 this is 2 Watts ERP (3.2 W EiRP).
Entrer la puissance de sortie RF souhaité sous forme d' un pourcentage de la puissance maximale
dans la zone d'alimentation Set. Cliquez sur le bouton ensemble d'alimentation . Remarque: le
maximum réel rayonnée de puissance RF est réglé en usine pour se conformer à la réglementation
de radio dans le pays d'utilisation. Aux Etats-Unis et au Canada c'est 4 Watts EiRP et selon la
norme EN 302 208 c'est 2 watts ( 3,2 W PIRE).
FCC Radiation Exposure Statement
The antenna used on this equipment must be installed to provide a separation distance of at least
23cm from all persons and must not be co-located or operated in conjunction with another antenna
or transmitter.
L'antenne utilisée sur cet équipement doit être installé pour fournir une distance de séparation d'au
moins 23cm de toutes les personnes et ne doit pas être co- implantés ou exploités conjointement
avec une autre antenne ou émetteur .
FCC Part 15 Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC and Industry Canada Modification Warning Statement
Modification of this device is strictly prohibited. Any modifications to the factory hardware or
software settings of this device will void all warranties and be deemed non-compliant with FCC and
Industry Canada Regulations.
La modification de ce dispositif est strictement interdite. Toutes les modifications apportées au
matériel d'usine ou les paramètres du logiciel de cet appareil annulera toutes les garanties et sera
considérée comme non conforme aux normes FCC et d'Industry Canada.
SASL User Guide v1.10 - Part # 11400-431
October 2015
Industry Canada Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device.
Cet appareil est conforme aux normes d'Industrie Canada exempts de licence(s) RSS. Son
fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer
d'interférences, et (2) cet appareil doit accepter toute interférence, y compris les interférences qui
peuvent provoquer un fonctionnement non désiré de l'appareil.
Power Disconnect Device
The plug on the power supply cord is intended to be the power disconnect device. The power
source (socket or outlet) shall be located near the equipment and shall be easily accessible.
La fiche du cordon d'alimentation est destiné à être le dispositif de coupure de courant. La source
d'alimentation (prise ou sortie ) doit être située près de l'équipement et doit être facilement
accessible .
Statement of Compliance with R&TTE Directive
RF Controls, LLC hereby declares that it’s ITCS-A-405 product is in compliance with the essential
requirements and other relevant provisions of European Directive 1999/5/EC. The original
Certificate of Conformity is available at www.rf-controls.com
RF Controls, LLC
1400 South 3rd Street, Suite 220
Saint Louis, MO 63104-4430
USA
Phone:
Fax:
e-mail:
+1 314 584-1500
+1 314 584-1549
techsupport@rf-controls.com Web site:
SASL User Guide v1.10 - Part # 11400-431
http://www.rfctrls.com
October 2015
10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 10
Language                        : en-US
Tagged PDF                      : Yes
Title                           : User Guide
Author                          : Chris Turner
Subject                         : SASL User Guide
Creator                         : Microsoft® Word 2010
Create Date                     : 2016:06:01 12:20:42-05:00
Modify Date                     : 2016:06:01 12:20:42-05:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WFQITCS-A-405

Navigation menu