RF Engineering and Energy Resource KI-GSM904 Water leak host panel User Manual Security GSM Alarm System
RF Engineering & Energy Resource, LLC Water leak host panel Security GSM Alarm System
User manual
99 Wireless +4 Wire Zones LCD GSM Alarm System User Manual Preface Thank you for purchasing our products. Please read through this manual before using this product so as to operate the product properly. The GSM alarm system adopts the newest GSM network and Digital Signal Processing Technology, and it is widely used in security field. With SMS data transmission and voice platform of GSM network. Perfect structure, convenient installation, easy operation with wireless control keyboard are designed for the idea of people-oriented, which will make you feel easy and comfortable while use this system. You only need to install the different sensors on the door or window,and preset necessary data on the panel. When any sensor is activated under arm status, the system will call and send SMS to owner’s telephone number immediately. What you need is to insert a local SIM Card which supports Call ID function and 2G network Note: More and more people are using 3G/4G sim card, please consult with your local SIM carrier whether it can be compatible to previous 2G network. If yes, this kind of 3G/4G SIM card can be used in our system. Contents I.Brief function....................................................................................................................3 2.About the main panel……......……….........……..............................…...............…..........4 3.Front function instruction……….....................….....….....................................................4 4.Back function instruction ………......………...................……............................…...........4 5.Wire terminal diagram………......………...................…….........................….......…........5 6.External siren volume adjustment………...................…….......................…........…........5 7.Tone of arm and disarm setting………......……….................................…............…........5 8.Telephone alarm numbers setting………......………............................…............….........6 9.GSM network signal inquiry…...................……............................…................................7 10.Zone type setting...………...................……........................…......…..............................7 11.Delay alarm time setting…......………...................……............................…......….........8 12.Delay arm time setting…......………...................……...............................…......….........8 13.Password protection enabled.……......………...................……................….....….........8 14.Operation Password…......………...................……..................................….....….........8 15.Coding /deleting remote control .………...................……......................….....…..........9 16.Coding /deleting wireless sensor ............……..............................…................…..........9 17.Call in ring times setting……......………................……..........................….....…...........9 18.New password setting......………....................……..........................…........................10 19.System reset……......………...................……............................…..............................10 20.Record setting……......………...................……..........................…...................….......10 21.System time setting………......………....................……..........................…....…..........10 22.Timely disarm setting.………......……................……............................….....…...........11 23.Zone name edited by SMS………......….............……..........................….........…........11 24.Zone name designation……......………...................……........................….......….......11 25.Power failure/recovery SMS alert…......………...................……..................................12 26.Disarm/Arm by SMS…......………...................……......................................................12 27.System status Query by SMS…......………...................……........................................12 28.12V voltage output start/stop by SMS…......………...................……...........................12 29.Handling the call alarm…......………...................……..................................................12 30.Remotely control by call…......………...................……................................................13 31.Understanding for CID protocol network …......………...................……......................13 32.Understanding for wire sensor connection…......………...................……....................14 33.Understanding for mark on LCD …......………...................……...................................15 34.Understanding for basic wireless accessories …......………...................……..............17 35.Maintenance…......………...................……..................................................................19 Brief Function 1.Built-in Newest GSM MODULE from famous supplier SIMCOM with 850/900/1800/1900MHZ frequency 2.Large LCD English blue back-light display, voice prompt, ease of use 3.With 99 wireless zones+4 wired zone totally 3. Preset max 6 group of alarm numbers, and program them freely to alarm with call only, or SMS only, or call+SMS 4.User can set zone type itself to 24hours alarm zone, burglarproof zone, delay alarm zone, home arm zone, Multi checked zone, Delay alarm zone, Bypass zone, Repeat triggered zone 5.Record a 10 second voice with alarm information in the host, played after user answer the alarm call 6.It can be compatible to CID protocol 7.Auto switch to built-in back up battery for external AC power failure 8.5 group of timely arm/disarm 9. SMS alert when AC power lost or recovered 10. Customized zone name freely by user via SMS Specification Rated Voltage: 9~12VDC 1A Standby current: 30-40mA Siren Output Voltage: 12VDC Working temperature: -10℃~+55℃ Humidity: ≤ 95% (no condensation) Stand-by power consumption: ≤0.6W Alarm response time:less than 8s The volume of siren :more than 115db About the main panel The main panel should be installed in the center of prevent place which could receive the signal very well from all wireless sensors. Please attention to keep the main panel away from metallic objects, steel-reinforced concrete, fireproof door, home appliance or any electricity device with high frequency interference 1.Front instruction Power: It will be on after you connect AC power or switch on back up battery Arming : It will be on if the system is away armed Home : It will be on if the system is home armed GSM: Disconnected GSM network with quick flashing.1 time each second Connected GSM network with slow flashing, 1 time every 3 seconds SET: It will be on under the status of programming ALARM: it will be on when the system is alarming It will flash when the system is armed 2.Back instruction 3. Wire terminal diagram Initialization Please insert the prepaid SIM card carefully at the back of main panel,and then plug in AC power.( If you want to recharge the back up battery, you need to switch on firstly and then plug in AC power) The LCD display will show [F5]→[F6]→[Signal strength ] one by one after you power on the system. It means the system is connected to GSM network. And the GSM LED indicator will flash slowly 1 time every 3 seconds System setting All the settings can be carried out under the disarmed status with a long ‘DI’ for all the proper operations. while two short sounds for wrong settings 1.External siren volume adjustment Under the disarm status, User can program the following command to adjust the volume of siren. The X is bigger, the sound will be bigger too.Finally press [#] again to end this operation. You will hear a long ‘DI’ sound to show correct setting. Command:[#]→[0]→[X]→[#] X=1-9: External siren sound will be bigger for bigger number X=0: External siren sound will be off 2. Human voice on or off User can close or open the human voice reminder as per your needs. Command:[*]→[0]→[4]→[X]→[*] X=1: Voice will be off X=0: Voice will be on 3.Tone of arm and disarm setting The external siren will give off response tone for each arm and disarm Command:[*]→[2]→[X]→[*] X=1: Enable siren response for arming and disarming X=0: Disable siren response for arming and disarming 4.Telephone alarm numbers setting User can preset max 6 groups of telephone alarm number,which the system will auto dial or send SMS to after alarm happened Command on the main panel: [#]→[X]→[telephone number]→[#] X=1: The 1st telephone alarm number X=2: The 2nd telephone alarm number X=3: The 3rd telephone alarm number X=4: The 4th telephone alarm number X=5: The 5th telephone alarm number X=6: The 6th telephone alarm number Example: #118200986586# to set 18200986586 as the 1st telephone alarm number 5.Telephone alarm numbers type setting User can set all 6 groups of alarm numbers as SMS alarm, Call alarm or SMS+Call alarm as per requirement Command:[#]→[X]→[A]→[#] X=(1-6): The series number of 6 group of telephone alarm numbers A=2: Call alarm type A=3: SMS alarm type A=4: Call+SMS alarm type nd Example: Set the 2 phone number to SMS alarm type: [#]→[2]→[3]→[#] 6.Telephone alarm numbers deleting User can delete any group of 6 telephone alarm numbers Command:[#]→[X]→[[#] X=(1-6): The series number of 6 group of telephone alarm numbers Example: Delete the 2nd phone number : [#]→[2]→[#] 7.Alarm log inquiry User can check the total 10 logs by press (0-9) numbers DIRECTLY on the panel on the disarm status Command:[X] X=(0-9), X=0: the latest log X=9: the last log Example: If you want to check the latest log, you can press 0, and found the LED indicator showing: It means that the latest log is emergency alarm 8. GSM network signal inquiry User can check the GSM signal before use on the main panel, so that the system can send alarm information successfully without any delay or missing. Command:[*]→[9]→[4]→[*] You will see the strength number on the LCD. If the number is less than 10, it means signal is bad. If the number is more than 30, it means no GSM signal. Bigger number means stronger signal for the numbers between 10 and 30 9.Zone type setting User can set all zones with any kind of different zone type Command:[#]→[8]→[A]→[B]→[#] A=(1-104): zone number Zone number 1-98 99 100 101-104 Wireless/wire zones wireless zone 1-wireless zone 98 useless useless 4 wire zone B=(0-8): 8 kinds of different zone type 0: inactive 1:burglarproof alarm 2:home arm 3: emergency alarm 4: multi checked 5: delay alarm 7: double trigger 8: doorbell Example: If you want to zone 15 to be home alarm type: [#]→[8]→[15]→[2]→[#] Inactive zone: The zone will be closed Burglarproof alarm zone: The sensors will trigger alarm under arming status, but it won’t trigger Alarm under disarming status Emergency alarm zone: No matter when the system is armed or disarmed, the sensors at emergency zone will trigger alarm. Which is mainly for smoke sensor, gas sensor, panic button etc Home arm zone: The sensors at home arm zone won’t trigger alarm under the home arm status, but other sensors will trigger alarm as normal Multi checked zone: Only 2 or more sensors at the same zone are triggered within 30 seconds, it will trigger alarm Delay alarm zone: The alarm only be started in the preset delayed time after triggered Double trigger zone: It will alarm when the sensor is triggered twice within 5-30 seconds, otherwise it won’t give off alarm Doorbell: It won’t give off alarm but “ding dong” doorbell sound for each trigger 10.Delay alarm time setting The alarm will start after delayed time you set Command:[#]→[7]→[A]→[#] A=0-99 seconds, max 99 seconds 11.Delay arm time setting The system will be armed automatically after delayed time you set after press arm button of remote control or main panel Command:[*]→[4]→[A]→[#] A=0-99 seconds, max 99 seconds Note: If you press ARM button twice, the system will be armed quickly without delay 12.Password protection enabled The panel will be protected by operation password in 26 seconds once you enable this function Command: [*]→[1]→[1]→[*] 13.Password protection disabled The panel won’t be protected by operation password once you disable this function Command: [*]→[1]→[0]→[*] 14.Operation Password The panel will require user to input password before any operation if user enable the password protection Command:[*]→[A]→[*] A=password, 4 digits. The defaulted password is 0000 15.Coding /deleting remote control Coding: User can press the command on the main panel, and trigger the signal out within 10 seconds by press any button on the remote control. You will hear a long DI sound to show coding successfully and LCD display showing 01. If you want to code second remote control, you can operate with the same way, and LCD display will show 02 accordingly Command: [*]→[0]→[*] Deleting: User can press the command on the main panel, You will hear a long DI sound to show ALL remote control will be deleted successfully Command: [*]→[0]→[2]→[*] 16.Coding /deleting wireless sensor Coding: User can press the command on the main panel, and send the signal out within 10 seconds by trigger the wireless sensor.You will hear a long DI sound to show coding successfully and LCD display showing its zone number. If you want to code more sensors, you can do it with the same way. Command: [*]→[8]→[A]→[*] A= zone number with 2 digits: 01,02,03,.....10......98 Example: we need to add 2 wireless door sensor to zone 05, and zone 98. We can do like this: Press command [*]→[8]→[05]→[*], trigger the first door sensor. You will hear a long ‘DI’ sound to show coding successfully. And then press command [*]→[8]→[98]→[*], trigger the second door sensor, you will hear a long ‘DI’ sound too Deleting: User can press the following command on the main panel, You will hear a long ‘DI’ sound to show deleting successfully Command: [#]→[8]→[A]→[6]→[#] A= zone number with 2 digits: 01,02,03,.....10......98. Example: we need to delete the wireless door sensor at zone 05. We can do like this: Press command [#]→[8]→[05]→[6]→[#] on the main panel. You will hear a long DI sound to show deleting successfully Note: If we want to delete all wireless sensors for all zones, we can press command [#]→[8]→[99]→[6]→[#] 17.Call in ring times setting The system will answer the call from user after preset “DU” ring times Command:[*]→[6]→[A]→[*] A= digits: 0,1,2,3.......... ; 0 means to disable the call in function Example: Require system to answer the coming call after 3 “DU” sounds, user can press command [*]→[6]→[3]→[*] on the main panel 18.Siren alarm time setting User can set the siren alarming time with 00-30 minutes. Command:[#]→[9]→[A]→[#] A=0-30 minutes 19.New password setting User can modify the system with new password in the case of forgetting the previous password Command:[*]→[7]→[A]→[A]→[*] A= new password with 4 digits .The defaulted password is 0000 Example: We need to modify the new password to 8585, we can press command [*]→[7]→[8585]→[8585]→[*] on the main panel 20.System reset All data will be cleared, except for coded sensors Command:[*]→[8]→[A]→[*] A= password, default password: 0000 Example: Press command [*]→[8]→[0000]→[*], the system will be reset 21.Record setting User can record 10 seconds voice to show alarm information including address, telephone number etc, which will be played on the alarm call Command:[*]→[0]→[A]→[*] A= system password Example:Press command [*]→[0]→[0000]→[*] on the main panel firstly, and say something within 10 seconds near to panel about 20cm. It will quit automatically when time’s out 22.System time setting Before installation, user can set the correct time for the system as per the following command Command:[*]→[0]→[7]→[A]→[B]→[C]→[D]→[E]→[*] A= Year, 15 means 2015, 16 means 2016 B=Month, 01 means Jan, 10 means Oct C=Day,11 means 11th ,08 means 08th, D=Hour, 08 means 8 o’clock, 09 means 9 o’clock E=Minute, 05 means 5 minute, 20 means 20 minute Example, Set system time to 2016 years at 12:25 on Oct 13th, user can press the command [*]→[0]→[7]→[16]→[10]→[13]→[12]→[25]→[*] Note: The system time will be clear if the system was off, so please switch on the battery for system in case of ac power failure 23.Timely arm setting System supports max 5 groups of timely arm, it will be armed automatically everyday as per the time Command: [#]→[0]→[7]→[A]→[B]→[C]→[#] A=Hour, 08 means 8 o’clock, 09 means 9 o’clock B=Minute, 30 means 30 minutes, 20 means 20 minutes C=Group number, max 5 groups 10 Example: Require 2 groups of timely arm at 08:30, 20:30 everyday, user can press the command [#]→[0]→[7]→[08]→[30]→[1]→[#], and [#]→[0]→[7]→[20]→[30]→[2]→[#] Note: if user want to cancel all timely arm, press command [#]→[0]→[7]→[00]→[00]→[0]→[#] 24.Timely disarm setting System supports max 5 groups of timely disarm, it will be disarmed automatically everyday as per the time Command: [#]→[0]→[8]→[A]→[B]→[C]→[#] A=Hour, 08 means 8 o’clock, 09 means 9 o’clock B=Minute, 30 means half minute, 20 means 20 minute C=Group number, max 5 groups Example: Require 2 groups of timely disarm at 08:30, 20:30 everyday, user can press the command [#]→[0]→[8]→[08]→[30]→[1]→[#], and [#]→[0]→[8]→[20]→[30]→[2]→[#] Note: if user wants to cancel all timely disarm, press command [#]→[0]→[8]→[00]→[00]→[0]→[#] 25.Zone name edited by SMS System can support max 9 groups of DIY zone name which is set by user via SMS on the mobile phone as per the following SMS command SMS command:【password】+【group number 1-9 】+【zone name】 For example, we can send the following SMS to the system ‘00001Door alarm’ ‘00002PIR alarm’ ‘00003smoke alarm’ ‘00004panic alarm’ Etc 0000 is the default password, 1 is the 1st group number, 2 is the 2nd group number, etc Door alarm,PIR alarm,smoke alarm, panic alarm is the zone name you set freely Note: zone name can be consisted of max 20 letters, including space 26.Zone name designation User can designate the 9 groups of zone name to regulated zone as per the following command on the main panel Command:[#]→[0]→[3]→[A]→[B]→[#] A=zone number B=1-9 group number of zone name For example: Require to designate the above 2nd of zone name: PIR alarm to zone 54, user can press [#]→[0]→[3]→[54]→[2]→[#]. If any sensor at zone 54 triggered, you will receive the SMS alarm : 54 defense area PIR alarm Note: This function was done on the panel directly, not via SMS 11 27.Power failure/recovery SMS alert Power failure: the system will send SMS “External power supply is disconnected, running on battery” and show L5 on the panel. Power recovery: Send SMS“External power supply recovery” and show L6 on the panel. Command: [*]→[0]→[5]→[A]→[*] A=2, enable SMS alert for power failure and recovery A=0, disable SMS alert for power failure and recovery 28.Disarm/Arm SMS response User will receive SMS response when the system is disarmed or armed. The SMS will be sent to the 1st of Group alarm number Command: [*]→[9]→[A]→[*] A=7, enable SMS response for armed and disarm operation A=6,disable SMS response for armed and disarm operation SMS response:“system is disarmed, home/away armed ” 29.Disarm/Arm programmed by SMS User can send SMS command to arm the system remotely SMS Command for Away arm:【password】+【SF】 Example: 【0000SF】 SMS Command for home arm:【password】+【BF】 Example: 【0000BF】 SMS Command for disarm:【password】+【CF】 Example: 【0000CF】 30.System status Query by SMS User can send SMS command to check the system status remotely SMS Command :【password】+【STATUS】 Example: 【0000STATUS】 31.12V voltage output start/stop by SMS User can send SMS command to start or close the 12V voltage output at the back of 12V terminal remotely SMS Command to start 12V output:【password】+【ON】 SMS Command to stop12V output:【password】+【OFF】 Example: 【0000ON】and 【0000OFF】 32.Handling the call alarm In case of alarm happened, system will make a call to user one by one. Once the user answers it, firstly it will play pre-recorded alarm voice on the call, after that, user can program the following command Press “1” to listen in Press “2” to start siren 12 Press “3” to close siren Press “4” to away arming Press “5” to disarming Press “6” to play records Press “7” to start12V voltage output Press “8” to stop 12V voltage output Press “#” to confirm and hang up automatically Note: If the user phone is busy or not able to connect, the system will dial next call alarm number until it is answered. 33.Remotely control by call You can call the numbers of system from any phone remotely, and the system will answer It automatically after system detects the call in ring times you set before. When you hear the beep, please input passwords and the system will allow you to program as per the following command Press “1” to listen in for 20 seconds Press “2” to start siren Press “3” to close siren Press “4” to away arm Press “5” to disarm Press “6” to play records Press “7” to output 12V electric power Press “8” to close 12V output Press “#” to confirm and hang up automatically Note: when you hear ‘DI DI’ sounds when you input the password, it means the password is wrong. You can try to input another new password. If the wrong times is more than 3, or no any operation within 20 seconds, the system will hang up automatically Understanding for CID protocol network This system is compatible with CID protocol. This function is convenient to work with central monitor station (CMS)for community, building, factory or bank etc 1.Enable/disable CID protocol network Once enable the CID network function, the system can work with CID international protocol center monitor station (CMS) Command: [*]→[0]→[9→[A]→[*] *09 2/1/0 * A=2/1/0 2:Enable, upload all alarm information, including arm/disarm information 13 1:Enable,upload alarm information, except for arm/disarm information 0: Disable 2.System ID for CID setting via SMS User can set unique ID for each system to work with CID protocol CMS. This operation needs to set via SMS SMS Command :【password】+【*】+【0】+【9】+【A】+【ID】+【*】 A= 4 digits Example, if user wants to set 6868 as system ID for CID CMS, send SMS 0000*096868ID* to the system 3.Alarm code for CID protocol network station setting CID defined that different alarm has its unique alarm code, so that CMS will recognize the alarm type according to the code Command: [*]→[0]→[9→[A]→[B]→[*] A=zone number (3 digits required) B=CID alarm code (3 digits required) For example,[*]→[0]→[9→[002]→[110]→[*] , 002 means zone 2, 110 is the alarm code of fire alarm, which is defined by CID protocol Understanding for wire sensor connection 1.Enable/disable wire zone setting User can disable or enable 4 pcs of wire zones as per the following command. Default setting is disable Enable Command: [*]→[0]→[6]→[1]→[*] Disable command: [*]→[0]→[6]→[0]→[*] 2.Wire zone No/NC type setting User can set the wire zones with normal open type or normal close type as per the following command. (Default setting is normal open type) Command: [*]→[9]→[A]→[B]→[*] A=zone number from 101-104. 101 for L1, 102 for L2, 103 for L3, 104 for L4. B=0/1/. 0: normal close. 1:normal open Example: Require to set wire zone 103 to be normal close for wire door sensor, user can press the command on the panel [*]→[9]→[103]→[0]→[*] 3.Wire sensor installation: Take wire zone 104 with wire door sensor for example Step 1: User need to enable the wire zone by command:[*]→[0]→[6]→[1]→[*]. The default setting is disable wire zones Step 2: Program wire zone 104 with NC type by command [*]→[9]→[104]→[0]→[*]. Note: 14 most of wire sensor is with NC type Step 3: Connect one wire of sensor to L4 port for zone 104, and the other wire to GND port Understanding for mark on LCD “SF”: Away arm “CF” : Disarm “bF” : Home arm “99” : Emergency alarm “1-98” : Wireless zone1-98 “L1-L4” : Wired zone 101-104 “F3” : No SIM card “ F4” : GSM is unavailable “F5” : Start GSM module to find GSM network “F6”: GSM network available Note: If the system always shows F4, please power off the system,and restart the system. Understanding for arm/disarm/emergency alarm 1.Away arm Press “ ”button on remote controller or “ ” button on panel and the system will be armed with BI tone and “ARMING” human voice. The system will alarm once any sensor is triggered under the status of away arm 15 2.Home arm Press “” button on remote controller or “ ” button on panel, the system will be home armed with BI tone and and “intelligent defenses” human voice. The system won’t alarm for trigger at home arm zone under the status of home arm 3.Emergency alarm Press “ ”button on remote controller 1 time, the system will show 99 flashing on the LCD display, and also start calling/SMS with silence. But if you press “ ” button again, the siren will start at once Press “ ” button on the main panel, the system will start calling/SMS with siren sound and “emergency alarm” human voice The system will alarm at once for any trigger at emergency zone no matter what it is armed or disarmed 4.Disarm Press “ ” button on remote controller or “ ” button on panel and the system will be armed with BI BI tones or “DISARM” human voice. The system won’t alarm for any trigger under the status of disarmed, except for emergency alarm 16 Understanding for basic wireless accessories 1.Wireless remote control To control the alarm host to arm and disarm With the emergency key for emergency help Operating power: 27A 12V alkaline battery Emitting distance: ≥100m (on the open area) Battery life: ≤1 year 2.Wireless Intelligent Door Sensor Generally set at burglarproof alarm zone If any door or window is opened, it will transmit the alarm signals to the alarm host Operating power: 23A 12V alkaline battery Frequency: 433.92MHZ Emitting distance: ≥100m (on the open area) Battery life: ≤6 months for normal frequency Trigger Distance: <1cm 17 3.Infrared detector installation Mainly monitor and control indoor space, generally set as home alarm zone. When human body enters into detecting area, the sensor will transmit signals to the alarm host. Operating power: 9V alkaline battery Emitting distance: ≥100m (on the open area) Battery life: ≤1 year for normal frequency Detecting distance: 110° 10×10m Installation height :2.2meters 4. wireless outdoor strobe siren Installed outdoor, with weatherproof function Once alarm happened, the strobe siren will give off alarm with flashing light Wireless frequency: 433mhz Operating back up battery : 300ma NI-HI battery inside Emitting distance: ≥100m (on the open area) Siren index: 115db AC power supply :AC220V, 50mhz input.12V DC,0.5/1A output Stand-by: 1mA, working mode: 350mA 18 How to let siren work with system? Firstly, plug in or switch on the battery of siren, you will see siren flashing quickly, which last only 6 seconds Secondly, Press DISARM button on the system panel to send signal out within 6 seconds after siren flashing quickly Thirdly, The siren will flash slowly after accepting the signal, and start alarming Finally, user can press DISARM button again to stop siren alarming Maintenance Alarm system are in use everyday, but must also conduct regular maintenance periodic testing. In order to ensure the alarm system works well, the main panel needs to comprehensive detection every 3 months, detectors tested monthly Host checking 1.Arm/disarm normally or not 2.Whether it can call or SMS after trigger sensor 3.Whether it can receive the signal from the sensor normally 4. Check regularly whether enough money in the SIM card Sensor checking 1. Trigger detector by hand, check whether it can be triggered or not 2. Check the batteries every 3 months Note Don’t dismantle,repair or renovation products, otherwise any accidents happened Don’t open the alarm system without permit for warranty items.if there is any questions about the operation, don’t hesitate to contact your local seller or manufacture by email. We or our agent will response to you within 24 hours Thanks for your kind reading, and sincerely you will have a good time with our system protection 19 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : USER Title : Security GSM Alarm System Create Date : 2016:03:21 15:18:24Z Creator Tool : WPS Office Modify Date : 2016:06:21 16:21:46+08:00 Metadata Date : 2016:06:21 16:21:46+08:00 Document ID : uuid:43783996-6e44-434f-a99f-83e8ad4c58c5 Instance ID : uuid:d390939d-75ac-463a-9c94-31840f9fbb49 Page Count : 21 Author : USEREXIF Metadata provided by EXIF.tools