RSI VIDEOTECHNOLOGIES WM00 Wireless Alarm Keypad User Manual Installation Manual
RSI VIDEOTECHNOLOGIES Wireless Alarm Keypad Installation Manual
Installation Manual
Programming/RF Testing*
1 Open the casing by inserting a flat head screwdriver and
lifting UP. The case will slide apart.
2 Insert 3 (minimum) SAFT 3.6v Lithium AA LS14500
batteries.
3A New Installation: Put the control panel into
keypad registration mode by pressing the
programming button of the control panel one time.
OR
3B Adding to existing system: Using a programmed
alphanumeric keypad, proceed through menus until the
display shows ADD A NEW DEVICE. Press OK. The
display shows PRESS PROGRAM BUTTON OF DEVICE.
OR
3C Adding to existing system without a keypad: Refer to
the installation manual of the control panel.
4 Press and release the programming buttons (CLR and
ESC/NO) on the WMB keypad. The keypad LED will flash.
Wait for keypad display to show KEYPAD# RECORDED.
5 Press OK. The display shows LANGUAGE: ENGLISH. Press
OK. (This prompt will only appear when performing a
new installation).
6 Display shows RADIO RANGE TEST? Press OK, the
keypad starts displaying the number of successful pings
to and from the control panel out of 9 (0/9 to 9/9).
Devices must be installed in a location with a stable 9/9 RF
test result to ensure reliable communication.
7 Press OK to end radio range test, then press Esc/No.
Note: If this is a new installation (3A), the keypad display
prompts other system configuration data. If adding a keypad to
an existing (operational) system, proceed to step 8.
8 When finished, exit from configuration mode.
Note: The control panel automatically assigns alphanumeric
keypads automatically to Area 1 (Entry/Exit delay)
*For complete details, refer to the control panel installation manual.
Product Summary
The Indoor Keypad Model WMB is designed for use in
configuring/programming and operating a VideofiedTM security
system. The keypad includes the following features:
> Lithium batteries for long life.
> 32 Character Display (2 lines x 16 characters)
> Built-in piezo for status and alarm sounds
> Dual tamper function provides detection of both
wall and cover tamper.
> Transmits check-in/status signal every 8 minutes.
> Built in Proximity Badge Reader
Installation Guidelines
For easier installation, programming and RF testing
should be completed before mounting the control panel and
devices.
Install the keypad and other system devices in the following
order:
> Programming/RF Testing - Program keypad and all other
devices into the control panel and test RF communication
from each intended device location to the control panel.
> Mounting - Mount keypad and devices at the tested location.
www.videofied.com
INSTALLATION DATA SHEET
Keypad WMB
Made by RSI VIDEO TECHNOLOGIES 2129-WMBIN February 2013
1. Mounting
> Use proper tools and hardware.
> Mount indoor in a temperature-controlled environment.
> Mount keypad at height that provides proper viewing and
convenience for the customer.
> Mount in a location that provides customer convenience but
out of view from windows.
1 Separate base from Keypad.
2 Hold base against mounting surface and mark the three
mounting holes. Use the left or right side to level the
keypad.
3 Drill pilot holes and install anchors where needed.
4 Place base on mounting surface so holes line up with
pilot holes/anchors and secure base with appropriate
screws.
5 Attach Keypad to base by lining up the tab with unlock
symbol and sliding closed and secure with optional screw.
Note: The WMB Keypad is a supervised device and
must be permanently mounted. This product is not intended
to be a roaming device.
Mounting Holes
2. LCD Overview
Icons for entry mode:
a..z Lowercase
A..Z Uppercase
123 Keypad
&@# Symbols
Icons for arming mode:
Partition 1 or SP1 selected
Partition 2 or SP2 selected
Unused
External arming mode selected
Unused
Information Icon
Low Battery Icon
www.videofied.com
Keypad WMB INSTALLATION DATA SHEET
Keys Description
Panic
The panic request is launched in two steps:
1. 3 second press on the PANIC key
2. 1 second press on one of the three assistance keys
- The transmitted event type and siren activity depend on programming
OK Used to confirm any data capture or acknowledge messages
ESC Exits the current menu or cancels all data entered
CLR Deletes the last character entered
Symbols
The symbols: 1 . _ @ $ , ‘ ? ! ; : “ ( =space) are accessed through the 1
key
• With multiple 1 second presses on the 1 key, the user is able to select the
symbol they are looking for.
• By pressing and holding the 1 key, the line with all symbols will show. Use
the arrow keys to select the symbol and press OK to confirm.
Special
Characters
Special Characters +0-*#=/%& ¥<>() are accessed through the 0 key
• With multiple 1 second presses on the 0 key the user is able to select the
special character they are looking for.
• By pressing and holding the 1 key, the line with all symbols will show. Use
the arrow keys to select the symbol and press OK to confirm.
Capital Letter Press and hold appropriate letter key then repeat press
Auto-Repeat
mode
When a user holds an arrow key, the keypad will scroll all available values
Re-sync and
Enrollment
Press and release ESC/NO and CLR buttons simultaneously
3. Product Overview
LCD display
with automatic
backlight
Arming Keys
Red /
Green LED
6. Keypad Use4. RFID Tag Reading
The WMB keypad is equipped with a badge
reader ISO/IEC 14443A. The optimal reading
area is located around the Videofied symbol.
Compatible with MiFare 13.56 MHz 1K/4K badges
(VT100).
The badge reader is inactive until approached
by a user. The system utilizes a capacitive
detector to energize the badge reader. It is
recommended the user holds the badge in place
rather than a quick swipe.
When a badge is detected the Green LED is lit
Menu Navigation
Assistance Requests
5. Security
- Remove batteries before any maintenance
- WARNING, there is a risk of explosion if a
battery is replaced by an incorrect type!
- Observe polarity when inserting batteries
- Do not throw away used batteries they must
be properly disposed of according to
Hazardous material regulations for Lithium
batteries
RFID Badge
reading zone
Legend
Chime Activation
System Status
Direct Bypass
WMB X2X
WMB X1X
www.videofied.com
Keypad WMB INSTALLATION DATA SHEET
Keypad WMB INSTALLATION DATA SHEET
Properties
Panel Compatibility Videofied Alarm Panel XL, XT, XTIP, XV, Visio
Power requirements:
Type: C
Battery Type SAFT, AA, Lithium, LS14500
Nominal Voltage: 3.6v
Low Voltage Limit:
2.1v - LCD will stop functioning but communication is working
3.0v - LCD will function and communication is working
Quantity 3
Battery life (estimated) Up to 4 years
RF Technology: S2View® Bidirectional Radio
Central Frequency WMB210 : 868MHz : (Europe, Africa, Asia)
WMB621 ; 915MHz : (USA, Canada, South America)
WMB721(: 920MHz : Australia, South America)
Transmission Security AES Algorithm encryption
Supervision 8 min polling
Antenna Integrated
Tamper:
Wall and cover tamper
Keypad:
Keys: 23x Keys
Allowed Time for Code Entry: 60s
Number of Available Codes: 1,109,814
Number of Illegal codes: 186 (depending on panel features)
User code input attempts before lockout: 5
Lockout duration: 90 seconds
Memory Lifetime: No Limit (Flash Memory)
Badge Reader:
Format: ISO/IEC 14443A
Type: MiFare 13.56MHz 1K/4K
Physical Data
Operating temperature 14° to 104° F (-10° to +40° C)
Maximum relative humidity 75%, non-condensing
Material A B S U L-V0
Dimensions (LxWxD) : 3.9 x 5.63 x 0.94 Inches
(99.1 x 143x 23.8 mm)
Weight 6.35oz (180gr) without batteries
Installation/Mounting
Wall Mount 3 Screws (including one for the tamper)
Case Lock Mechanical slide lock and optional screw
Certification & Standards
868MHz: WMB210
Standards:
EN60950-1:2006+/A11:2009+/A1:2100
EN300220-1 V2.3.1
EN300220-2 V2.3.1
EN302291-1 V1.1.1
EN302291-2 V1.1.1
NF EN50130-4:1995+/A1:1998+/A2:2003;
NF EN50130-5:1998 Classe II
NF EN50131-3:2009 - Grade 2
NF EN50131-5-3:2005 - Grade 2
NF EN50131-6:2008 Grade 2 –Type C
Certifications:
Europe CE / EN50131 Grade 2
Pays-Bas NCP
Singapour IDA
Afrique du Sud ICASA
915MHz FHSS: WMB611, WMB621
Certifications:
USA FCC Part 15C (FCC47 CFP part 15)
Canada IC (RSS-210 Issue 8)
920MHz FHSS: WMB711, WMB721
Certifications:
Australia C-Tick (AS-NZS4268)
Assistance Request Police/Medical/Fire
Display type Liquid-crystal (LCD)
Display size 32 characters total: Two lines, 16 characters each
Display backlighting Automatic
Built-in sounder:
Piezo Buzzer: Emits entry/exit delay beeps, alarms
Panic button One (Must be programmed/Enabled)
PRODUCT SPECIFICATION SHEET
Keypad WMB
FCC Regulatory Information for USA and CANADA
FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC
authorization to operate this equipment.
FCC Part 15.105 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
EMEA SALES
23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
Hotline: +33 (0)820 846 620
Fax: +33 (0)1 82 69 80 10
© 2011 RSI VIDEO TECHNOLOGIES. VIDEOFIED® is a Registered Trademark of RSI VIDEO TECHNOLOGIES.
S2View® is a registered trademark of RSI VIDEO TECHNOLOGIES. Specications subject to change without notice.
USA SALES
1375 Willow Lake Blvd. #103
Vadnais Heights, MN 55110
USA
Hotline: +1 877 206 5800
Fax: +1 651 762 4693
www.videofied.com