RadarFind R221012 INDOOR EQUIPMENT LOCATION SYSTEM User Manual Reader Installation Manual V2

RadarFind Corporation INDOOR EQUIPMENT LOCATION SYSTEM Reader Installation Manual V2

Contents

Installation Manual

Download: RadarFind R221012 INDOOR EQUIPMENT LOCATION SYSTEM User Manual Reader Installation Manual V2
Mirror Download [FCC.gov]RadarFind R221012 INDOOR EQUIPMENT LOCATION SYSTEM User Manual Reader Installation Manual V2
Document ID1074696
Application IDwQwHde3tr38UUpZCUTO+BQ==
Document DescriptionInstallation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize141.49kB (1768608 bits)
Date Submitted2009-03-02 00:00:00
Date Available2009-03-03 00:00:00
Creation Date2008-12-05 15:24:07
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2008-12-05 15:24:07
Document TitleMicrosoft Word - Reader_Installation_Manual-V2
Document CreatorPScript5.dll Version 5.2.2
Document Author: sfisher

PLM Reader
Model R22-1012 with P10-xx10 PlugSert option
Installation Instructions
RadarFind™ Corporation
877-RadarFind (723-2734)
www.radarfind.com
Copyright © RadarFind Corp 2008
Radarfind Corporation
PLM Reader Installation Instructions
12/5/2008
Page 2 of 10
DANGER:
Cautions:
•
Risk of electric shock. Disconnect all supplies before working on any
circuit.
•
It is important to follow all instructions shipped with this product.
Failure to follow all safety precautions and instructions may result in
property damage, serious injury, or death to you or others.
• Risk of malfunction. Use only copper wires of size 12AWG (or larger)
suitable for 105°C (221°F).
• Installation should conform to national, state, and local electrical codes.
• Gauge of electric supply wires should be of appropriate section, function of
line current, as per NEC electrical code.
• This device must be installed directly into the electrical system.
• This device must be installed by a trained and licensed electrician who is
thoroughly familiar with the National Electrical Code and follows the NEC
Guidelines as well as state and local codes.
[15.19] This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
[15.21] Information to user: Changes or modifications not
expressly approved by the RadarFind Corporation could void the
user's authority to operate the equipment
Reader Model
R22-1012
Fcc ID:
URGR221012
[15.105] NOTE: This equipment has been tested and found to
comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.
Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be
required to correct the interference at his own expense.
[15.247] This equipment operates under Section 15.247 of the
Title 47 FCC Rules.
[15.249] This equipment operates under Section 15.249 of the
Title 47 FCC Rules.
Copyright © RadarFind Corp 2008
12/5/2008
Radarfind Corporation
PLM Reader Installation Instructions
Page 3 of 10
General Safety Information
•
•
•
•
Wear safety goggles when working under conditions that might be hazardous to your
eyes.
Keep tools where you and others will not fall over them.
Keep the installation area clear during the installation.
Do not wear loose clothing that could become caught in the equipment.
Electrical Safety Information
•
•
•
•
•
Before working on electrical equipment, remove jewelry (necklaces, rings, watches, and
so on).
Locate the emergency on/off switch closest to the installation site.
Before installation, turn OFF the power.
Refer to the site’s safety precautions for details about site-specific hazards.
Refer to the Reader name plate for information on voltage and current.
Copyright © RadarFind Corp 2008
Radarfind Corporation
PLM Reader Installation Instructions
12/5/2008
Page 4 of 10
Preparing for Installation
Note: Read all instructions before installing or operating this equipment.
Site Selection Criteria
The selection of the mounting location for the reader and the method of connecting it into the
existing electrical system must be accomplished under the direction of the facilities engineer and
the safety engineer responsible for the proposed building or location.
The installation location must be indoors and protected from all weather and water. All provided
mounting fasteners must be used for secure and safe attachment.
Equipment Assessment
Caution:
If the equipment is damaged, do not attempt to install or operate it.
1. When the equipment arrives, unpack the unit(s).
2. Check for damage that may have occurred in transit.
3. Contact the carrier immediately to file a claim stating the extent of the damage, or contact
Radarfind customer service for repair or replacement.
4. Review the following checklist to ensure that all necessary materials are available for
installation.
Reader unit
2—3/4” #6 screws – For mounting Reader
to existing electrical box. Wired Reader only
4—hollow wall “Polly” anchors
4—3” #6 screws for use with the “Polly” wall
anchors
4—plastic mounting hole plugs
Copyright © RadarFind Corp 2008
Radarfind Corporation
PLM Reader Installation Instructions
12/5/2008
Page 5 of 10
Installing a RadarFind Plug-in Reader
Warning: ALWAYS confirm that Location ID label on top of Reader matches
Location ID on map for where Reader will be installed. If it is necessary to
install a Reader in any other location for any reason RadarFind must be
notified immediately.
Note: A RadarFind Reader can only be installed with the ground pin orientation the same
as the existing receptacle. If it is necessary to install a Reader 180 degrees off-axis from
the existing receptacle the orientation of the existing receptacle must be reversed by an
electrician.
Plug-in Installation Procedure
1. Unscrew Reader receptacle plate screw approximately ¾”
2. Remove existing receptacle cover plate.
3. Plug Reader into existing receptacle
4.
Level Reader and mark wall for four corner
mounting anchors.
5. Remove Reader.
6.
7. Insert included wall anchors at punch marked locations, tighten
until securely compressed into wall, then remove screws from
anchors and discard. (The heads on the anchor screws are too large to be
used in the Reader)
8. Plug Reader into receptacle.
9. Insert and secure 4 corners using the (4) 3” #6 screws,
tighten to 12 inch pounds.
10. Tighten Reader receptacle cover plate screw
11. Plug four corner holes with plugs provided.
Copyright © RadarFind Corp 2008
12/5/2008
Radarfind Corporation
PLM Reader Installation Instructions
Page 6 of 10
Hard wiring a Reader
In places where the Reader must be installed off-axis to the receptacle or over a quad
box the Reader Plug-Sert must be removed and the Reader must be wired directly into
the receptacle box.
Removing the Plug-Sert from Reader
1. Remove Reader back plate
2. Remove Reader cover plate
3. Loosen Plug-Sert wire tap screws, from
the bottom front of the Reader behind
the receptacle
4. Pull Reader tap wires out of PlugSert from inside the back of the
Reader
5. Remove receptacle mounting
screws
6. Pull the Plug-Sert out of the front
of the Reader
7. Feed Reader tap wires through slots
in Reader cavity
8. Replace Reader back plate
9. Proceed with wired Reader instructions
on next page.
Copyright © RadarFind Corp 2008
12/5/2008
Radarfind Corporation
PLM Reader Installation Instructions
Page 7 of 10
Hard wired Reader Installation Procedure
1. Turn off the power to the outlet.
2. Remove the existing receptacle cover plate and
mounting screw, set aside screws for use later.
3. Unscrew receptacle, save screws for later use, and pull
receptacle out of box.
NOTE: If Reader orientation is off axis to the existing receptacle or if
the existing receptacle is an quad see Reader mounting adapter
plate 80-000-1019 adapter plate. (Pg. 10 )
4. Start bottom receptacle
mounting screw from
installation kit into the box hole,
(YELLOW) leaving approx ½”
protruding, cut screw if required
to avoid contact with wires in
the box.
5. Pull receptacle through Reader
from back and place Reader
temporarily over box, sliding
slot in Reader mounting frame
over bottom box screw, level,
and mark corner holes with
punch.
6. Remove Reader. Insert included
wall anchors at punch marked
locations, tighten until securely
compressed into wall, then
remove screws (RED) from
anchors and discard. (The heads
on the anchor screws are too large
to be used in the Reader)
7. Start top receptacle mounting
screw into the box hole,
(YELLOW) leaving approx ½”
protruding, cut screw if required
to avoid contact with wires in
the box.
Copyright © RadarFind Corp 2008
12/5/2008
Radarfind Corporation
PLM Reader Installation Instructions
Page 8 of 10
8. Wire Reader into circuit with Reader leads
protruding from rear of Reader.
9. Pass receptacle through reader cavity and tip
Reader onto the protruding box screws (RED) by
sliding slotted end of metal mounting frame onto
bottom screw, tipping the Reader to left and
turning clock-wise onto top screw.
IMPORTANT ! Use caution to assure that no wires
are caught under metal Reader frame.
10. Tilt the Reader
straight, level, and
tighten box screws
loosely.
11. Insert and secure 4
corners using the (4)
3” #6 screws, tighten
to 12 inch pounds.
12. Tighten box screws
(RED) and reinstall
receptacle onto
Reader mounting
bracket using the
original receptacle
screws, tighten to 12
inch pounds.
13. Replace outlet plate and cover four mounting
holes with plastic plugs, provided.
14. Restore power to the outlet.
Note : See Reader mounting adapter plate (Pg. 10 ) for mounting at 90 Degrees to single gang
receptacles or on quad-box receptacles.
Copyright © RadarFind Corp 2008
12/5/2008
Radarfind Corporation
PLM Reader Installation Instructions
Page 9 of 10
Accessories
Reader mounting adapter plate – 80-000-1019
In some cases other objects near a receptacle, such as railings or cabinets, will prevent
the Reader from being installed in its default position or orientation. RadarFind Readers
may be hard wired at a 90 degree angle over single gang wall receptacles or in any
orientation over quad receptacles with the accessory adapter plate.
1 – Remove PlugSert module from Reader
2 - Remove cover plate and receptacle mounting screws,
tip receptacle up from wall.
3 – Install adapter plate with tapped 6/32 Reader mounting
holes for desired Reader orientation.
4 – Install Reader onto adapter plate according to the
Hard wired Reader Installation Procedure.
Copyright © RadarFind Corp 2008
12/5/2008
Radarfind Corporation
PLM Reader Installation Instructions
Page 10 of 10
Tamper-resistant mounting accessories
RadarFind R11-1411 Readers are packaged with standard 6/32 combination head screws
for the center plate retention screw and the four corner anchor screws. Tamper resistant
screws and matching drivers are available as accessories.
Note: The Reader UL 914C approval - for use as an electrical extension ring - when installed as a
direct wired device requires the use of the provided wall anchors on all four corners. The 50-1001020 tamper-resistant screws are custom manufactured for use with these UL approved wall
anchors.
RadarFind R11-1411 Reader Accessories
Part Number
Description
80-100-1019
Adapter mounting plate for R11-1411 Reader
50-100-1019
(1) 6/32 2” tamper-resistant center plate
screw for R11-1411 Reader
50-100-1020
(4) 6 /32 3” tamper-resistant wall mounting
screws for R11-1411 Reader
50-100-1021
Tamper-resistant screw driver for 50-1001019
50-100-1022
Tamper-resistant screw driver for 50-1001020 for R11-1411 Reader
Copyright © RadarFind Corp 2008
Radarfind Corporation
PLM Reader Installation Instructions
12/5/2008
Page 11 of 10
Technical Specifications:
Part # - R22-1012
AC supply:
Power:
108-130 VAC RMS, single phase 60HZ
1.2 VA
Double Insulated
Communications:
RF frequency range:
Transmit power:
Antenna:
Operating:
Dimensions:
FHSS FCC Subpart 15.249 and 15.247
FSK channel between 902 and 928 MHz
+8dBm maximum
6 dB gain cardioid
0 to 40º C, 5% to 90% RH, non condensing
5” W x 12.3” L x 2.25” D
(4 mounting holes for wall anchors)
©2008 Radarfind™ Corporation. All rights reserved. Printed in the USA
Copyright © RadarFind Corp 2008

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2008:12:05 15:24:07-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:12:05 15:24:07-05:00
Format                          : application/pdf
Creator                         : sfisher
Title                           : Microsoft Word - Reader_Installation_Manual-V2
Document ID                     : uuid:65f7d1a6-c109-4fd1-8b31-c04475802986
Instance ID                     : uuid:81ae5e05-6743-4a30-90fa-5f0c77f995e1
Page Count                      : 11
Author                          : sfisher
EXIF Metadata provided by EXIF.tools
FCC ID Filing: URGR221012

Navigation menu