Radiance Instruments 820T Wireless Fridge Thermometer User Manual

Radiance Instruments Ltd. Wireless Fridge Thermometer

USER MANUAL

Download: Radiance Instruments 820T Wireless Fridge Thermometer User Manual
Mirror Download [FCC.gov]Radiance Instruments 820T Wireless Fridge Thermometer User Manual
Document ID3989731
Application ID3uZdC54s3+aMZF9g9Xmjvw==
Document DescriptionUSER MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.98kB (212311 bits)
Date Submitted2018-09-04 00:00:00
Date Available2018-09-04 00:00:00
Creation Date2018-08-17 08:54:10
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2018-08-17 08:54:10
Document TitleUSER MANUAL
Document CreatorMicrosoft® Office Word 2007
Document Author: User

Radiance instruments Ltd.
Da Jing Village, Si Jiao Lou,Luo Yang Town,Hui Zhou City,China
Phone: 0752-6831106/6831108(126) Fax: 0752- 6832319
Postcode: 516171
E-mail:wubz@liheng.net
PRODUCT USER MANUAL
Product number:RT820RF Product name: Wireless fridge thermometer version: V1.1
Feature:

2.4GHZ wireless fridge thermometer。

IP65 waterproof for transmitter.

HIGH/LOW alarm setting.

Maximum temperature and current temperature reading.

FCC,CE, NSF and ROHS compliant.



Low battery indication.
C / F exchange
Magnetic attachment
Specification:
Measuring range
Temperature accuracy
Display resolution
Temperature reading update
Transmitter battery life
Receiver battery life
Working temperature
Wireless distance
Receiver size
Transmitter size
Receiver display size
Transmitter battery
Receiver battery
-25 ~ 50C/-13 ~ 122 F
±0.5℃/0.9℉
0.1
10 seconds alarm active,30 seconds normal
About 6000 hours
About 4000 hours(no alarm)
25 ~ 50 C for transmitter, 0 ~ 50 C for receiver
50 meters (open field, about 10 meters into the fridge)
65(W) x 97(H) x 20(D) mm
110(L) x 35(D) x 30(Ф) mm
37(W) x 37(H) mm
3 volt battery, type AAA X 2 or equivalent
3 volt battery, type AAA X 2 or equivalent
Operation
Put the transmitter into the fridge and put the receiver outside the fridge.
C / F exchange
Select the temperature unit C or F by the switch on the back side.
Receiver
1)
Press [
2)
After about 10 seconds, the receiver will receive the signal from the transmitter and display the
] button to turn on the unit, press the button and hold for 3 seconds to turn off.
temperature. The reading will be update 10 seconds.
Transmitter
1) Press[
] button to turn on the unit, red LED flash 5 times, press and hold for 3 seconds to turn off the unit,
red LED flash 2 times.
2) In normal working, it will send out the signal each 30 seconds and the LED flash.
Alarm setting
1) Press [
] button to turn on or off the alarm monitor.
2) Press [Set] button and hold 5 seconds to enter the low temperature alarm setting mode, the value flash. Press
[▲] or [▼] to set the low alarm value. After finish the low alarm setting, press [Set] button once again to enter
the high temperature alarm setting mode, set the value as above. Press the [Set] button to finish alarm
setting .
3) When the current temperature lower or higher the limited, the alarm sound active and LED flash. Press any
key to silent, but the LED flash continue, until the temperature come back to the safe rang.

When the alarm sound active 60 seconds continue, the sound will be silent 30 seconds and sound “bi、bi”
。
Maximum temperature clear
1) Press[▲] and [▼] buttons for 3 seconds to clear the maximum temperature.
Code rematch
1) The transmitter has paired with the receiver before delivery. If you want to rematch the unit code, turn off
the receiver at first, then press and hold [
] button for 5 seconds to enter the code rematch mode.
“Sync” icon display。
2) Turn off the transmitter at first,then press and hold [
] button for 5 seconds to enter the code rematch
mode。
3) The unit will be store the code automatically and then return to the normal working mode。
ERROR SYMBOLS:
Symbol
LLL.L
HHH.H
Sync
Description
Transmitter low battery voltage
Receiver low battery voltage
1) Sensor open circuit
2) The reading is out of low range (-50C/-58F)
1) Sensor short circuit
2) The reading is out of high range (70C/158F)
Code rematch
Action required
Replace the battery with the same type
Replace the battery with the same type
1) Return the thermometer for repair
2) Keep the measurement above low range
1) Return the thermometer for repair
2) Keep the measurement below high range
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator
and your body. This device complies with Industry Canada Licence-exempt RSSs. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference, including interference that m
ay cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada
applicable aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1)
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Changes or Modifications not expressly approved by the party responsible could void the user’s authority to
operate this device.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
TRANSMITTER FCC ID: 2AI67-820T
IC: 22116-820T
Mark Wu
2018-AUG-17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Language                        : zh-CN
Tagged PDF                      : Yes
Author                          : User
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2018:08:17 08:54:10+08:00
Modify Date                     : 2018:08:17 08:54:10+08:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AI67-820T

Navigation menu