Radiance Instruments SIGNALS Signals User Manual
Radiance Instruments Ltd. Signals
user manual
Radiance Instruments Ltd. PHONE: 0752-6831106/6831108(EXT126) FAX: 0752- 6832319 PRODUCT SPECIFICATION Product number: TMW022 Product name: Signals Versions: V1.1 Features: 4 Channel standalone BBQ/Oven Monitor. Uses Bluetooth for easy Wi-Fi Setup Can use either Bluetooth or Wi-Fi for monitoring. IP66 waterproof. High/low alarm setting. Loud alarm sound Lithium battery and power adapter Specification: Measuring range Temperature accuracy Wireless distance Display resolution Alarm sound volume Unit reading update APP reading update Water resistant rating Power Battery life Battery recharge time Display size Probe Product size Working temperature Attachment -58 ~ 572 F / -50 ~ 300C ±1.8F(±1C) between -4F to 248F( -20 to 120C) ±3.6F(±2C) between -58F to -4F / 248 to 392F(-50 to -20 C /120 to 200C) ±5.4F (±3C) between 392~572F(200 to 300C) About 95 feet (29 meters) (it depends the mobile phone) Current temperature 0.1,alarm limit set 1 About 90dB (300mm distance) 1 second 5 seconds IP66 Adapter power input and 1800mAh lithium battery About 15 hours About 12 hours 101(W) X 48 (H) mm Curved probe: 3.5() x 150(L) mm, tip 2.2() x 10(L) mm, cable length 1200mm. Straight probe: 3.5() x 51(L) mm, cable length 1200mm. 132 (W) x 83(H) X 49(D)mm Main part 32 ~ 122 F/0 ~ 50 C, cable 700F/371C, probe handle 644F/340C 3 pieces curved probes, 1 piece straight probe, 1 piece air clip, 1 piece type C USB cable 2,000 mm length, 1 piece power adapter (100-240ACV input, 12VDC/1000mA output) . Operation 1. Insert all the probes with the correct number. Connect the external power. 2. Press [ ] button to turn on the unit, the backlight will turn on 10 seconds. 3. Press [ ] button and hold for 3 seconds to turn off the unit. Select temperature unit Press [ ] button and hold for 5 seconds with the unit turn off to change the temperature unit. Low and high temperature alarm setting 1. Press [CH] button to select the channel for alarm setting. All the icons flashing that you selected. 2. Press [SET] button to enter alarm on-off setting. Press [▼] or [▲] button to set the alarm on or off. 3. Press [SET] button once again to enter high alarm limit setting mode, high alarm value will be flashing. Press [▼] or [▲] button to set the high alarm limit. 4. Press [SET] button once again to enter low alarm limit setting mode, low alarm value will be flashing. Press [▼] or [▲] button to set the low alarm limit. 5. Press [SET] button once again to finish the alarm setting. 6. If the temperature reading is out of the limited, the alarm will sound, the “LOW ALARM” or “HIGH ALARM” icon flash. Press any key to stop the alarm sound, the low alarm or high alarm icon will be flashing continue. 7. Alarm sound: the channel 1 alarm sound is “di - - -“, the channel 2 alarm sound is “di di - -“, the channel 3 alarm sound is “di di di -“, the channel 4 alarm sound is “di di di di “. * If the both alarms sound active, the last alarm sound will be instead the before one. * The default low alarm value is 32F, the default high alarm value is 160F, Backlight control 1) Press [ ] or [ ] button to switch backlight on or off. The backlight will be turn on 20 seconds, and then turn off automatically. Volume adjustment 1.Press [VOL] button to adjust the sound volume. 2. When the volume class is , it mean that the alarm sound is off. 3. When power up, the sound volume class is the third class. APP function: 1. Bluetooth APP for reading the data, set alarm limited, set temperature unit, set WIFI SSID and password. 2. WIFI APP for reading the data. 3. While the data sending out, the icon or flash. NOTE: 1. Clean the probe immediately with cleaning wipes after each measurement to avoid cross contamination. 2. Do not expose thermometer to temperatures over 50C / 122F or use in ovens, otherwise incorrect readings or damage to the thermometer may result. ERROR SYMBOLS: Symbol LLL.L HHH.H NO PROBE Description Full battery Icon flashing, charging battery Low battery indication The reading is out of low range (-50C) 1) Sensor short circuit 2) The reading is out of high range (300C) 1.The sensor open circuit 2.The sensor probe is not connect Action required Connect the power adapter to recharge Keep the measurement above low range 1) Return the thermometer for repair 2) Keep the measurement below high range 1) Return the thermometer for repair 2) Connect the sensor probe correctly This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with the RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. Ce matériel est complété par un dispositif de radioexposition de la radioactivité pour un environnement non réglementé. Ce matériel devrait être installé et se faire avec une distance de 20 centimètresEntre les radiateurs et votre corps. This device complies with Industry Canada Licence-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicable aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Changes or Modifications not expressly approved by the party responsible could void the user’s authority to operate this device. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC ID: 2AI67-SIGNALS ,IC: 22116- SIGNALS Mark Wu 2018- SEP-4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Create Date : 2018:09:04 14:43:30+08:00 Creator Tool : Microsoft® Office Word 2007 Modify Date : 2018:10:08 11:18:31+08:00 Metadata Date : 2018:10:08 11:18:31+08:00 Format : application/pdf Creator : Kevin Owen Producer : Microsoft® Office Word 2007 Document ID : uuid:9f81e6a3-8d4d-4ef1-b67b-d199dc0d0638 Instance ID : uuid:1cdb7994-12eb-44fb-a4aa-49aa2249c81f Has XFA : No Page Count : 3 Language : zh-CN Author : Kevin OwenEXIF Metadata provided by EXIF.tools