Radio Frequency Systems WINS-3900002 iDEN / TETRA Off-air-repeater User Manual
Radio Frequency Systems Inc iDEN / TETRA Off-air-repeater
User Manual
800MHz-900MHz ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS OR1-SBHP1-800 OR2-SBHP1-800 OR2-SBHP1-S800 OR1-SBHP1-900 OR2-SBHP1-900 OR1-SBHP1-900R OR2-SBHP1-900R Doc. code 91 080 0716F - Rel. 06 TECHNICAL HANDBOOK Radio Frequency Systems Kabelkamp 20 30179 Hannover, Germany Tel.: +49 511 676 2731 Fax: +49 511 676 2515 E-mail: sales.europe@rfsworld.com INDEX 1) SAFETY RULES ................................................................................................................................... 1 2) STANDARDS ........................................................................................................................................ 2 2.1) MANUFACTURE LABELS 2.2) SYMBOLS 3) GENERAL DESCRIPTION ................................................................................................................... 3 3.1) EXAMPLE: USE IN TUNNELS 3.2) OPERATING PRINCIPLE -800 / 900MHz ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS 3.3) ATTACHED DOCUMENTS 4) INSTALLATION AND POWER-UP PROCEDURES............................................................................ 4 4.1) INSTALLATION A - INITIAL CHECK B - POSITIONING THE REPEATER C - POWER SUPPLY SOURCE CONNECTIONS AND ALARMS CONNECTIONS D.C. POWERED EQUIPMENT AC POWERED EQUIPMENT (ALTERNATE CURRENT) 4.2) POWER-UP 4.3) CLOSING THE EQUIPMENT 4.4) ROUTINE MAINTENANCE 800MHz-900MHz Off-Air Repeaters (OR Series) UPDATINGS 91 080 0716F – Rel.06 1 1) SAFETY RULES 1.1 Introduction The equipment described in this technical handbook has been designed and tested in conformity of international safety standards IEC215 / EN60215 and IEC950 / EN60950; the equipment has to be used under the responsibility of specialised personnel only. In accordance with IEC215 / EN60215, adjustment, maintenance and repair of the exposed equipment shall be carried out only by qualified personnel, who are aware of the hazards involved. The minimum qualifications are established in the standard. Final installation of the systems must fulfil the EMF emission levels, as requested by regulations in force (recommendation n. 1999/519/EC). WARNING: Installation Notes Modular equipment, intended to be housed insidea rack cabinet, must be installed within a protected access area only. This area must be opportunely protected by security system that will exclude the entry, even if accidental, to not authorized and trained personnel. Alternatively, the cabinet, in which the equipment is housed, must be closed on all sides, to allow the access to internal parts to authorized personnel only 1.2 AC Power supply When working on the equipment always make sure that the equipment is not connected to the mains supply. Before power up always make sure that the equipment is connected to earth by using the equipment grounding bolt. If it is necessary to fit an AC power supply plug to power cable, the User must observe the following colour codes: LIVE terminal to BROWN lead NEUTRAL terminal to BLUE lead EARTH terminal to GREEN/YELLOW lead The User must also ensure that the protective earth wire would be the last to break, should the cable be subject to excessive strain. 1.3 Safety precautions For the correct and safe use of the equipment it is essential that both operation personnel and services personnel follow generally accepted safety procedures (see IEC Publications 215: "Safety measures for radio transmitting equipment" and 61010-1: "Safety requirements for electrical equipment for measurement, control, and laboratory use") in addition to the safety precautions specified in this technical handbook. Specific warnings and caution statements, where applicable, can be found throughout this technical handbook. Warning and caution statements and/or symbols are marked on the equipment where is necessary. (see also ANNEX n°1). As far as the equipment safety devices are concerned please remind that: -periodic functional check shall be carried out on protective devices; -functional check shall be carried out on protective devices, when they have operated under fault conditions; -safety devices shall not be altered or disconnected except for replacement; -safety circuit shall not be modified. SAFETY RULES Page 1 ENG 1.4 Caution and warning statements Caution It's used to indicate the correct operation and maintenance, in order to prevent damage or destruction of equipment or other property. Warning of danger Used to indicate the potential hazard that requires correct procedures or practices in order to avoid personal injury. 1.5 Impaired safety protection Whenever it is likely that safe operation is impaired, the apparatus must be in-operative and secured against unintended operation. The appropriate servicing staff authority must be informed. For instance, the safety is likely to be impaired if the equipment fails to perform the prescribed measurements, or shows visible damages. 1.6 Electrostatic sensitive devices In case of electrostatic sensitive devices ( for instance all ICs and many other semiconductor devices belong to this class) it is essential to use a right protection to reduce the risk of personal injury. Careless handling, during repair, may imply life danger. When repairing, make sure that you are connected with the same potential as the ground of the equipment by means of the right devices, i.e. a GIRDLE (a wrist wrap with resistance) and a WINDING CORD to be connected to the girdle and to the relevant socket placed on the equipment. You must also keep components and tools at this potential. 1.7 Electrolytic Capacitors Non-solid electrolytic capacitors must not contain chemicals, which may be regarded as hazardous, if incorrectly handled. Caution is necessary, should the outer case be fractured. 1.8 Electric shock In case of electric shock it is recommended not to touch the person before breaking the circuit by means of the power supply switch; should it be not possible to break the circuit power supply it would be advisable to try to rescue the person by means of some insulating materials: e.g. a wood stick, a nylon cord or a suitable service made of plastics, etc. NEVER TOUCH ELECTROCUTED PEOPLE WITH YOUR HAND AS LONG AS THEIR BODIES ARE SUBJECTED TO VOLTAGE, OTHERWISE YOU TOO WOULD GET ELECTOCUTED. Call the doctor and then immediately perform the artificial respiration as described here below: SAFETY RULES Page 2 ENG Lay the patient on his back with his arms parallel to his body; if the patient lies on an inclined plane, please make sure that his stomach be slightly lower than his breast. Open the patient's mouth and check if there are foreign bodies. Kneel down near the patient at the same level as his head's, put one of your hands under his head and the other one under his neck. Lift the patient's neck and let his head fall backwards the most possible. Shift your hand from the patient's neck to his chin; put your thumb between his chin and his mouth, your forefinger along his jawbone, keep your other fingers tight. By doing these operations start the self-oxygenation by means of deep breathings in standing open-mouthed. With your thumb between the patient's chin and his mouth, keep the patient's lips closed and blow into his nasal cavities. During these operations see if the patient's breast rises. If it is not so, his nose may be obstructed; in this case, by levering on his chin with your hand, open the patient's mouth, put your lips on and blow into his oral cavity. Look at the patient's breast and see if it rises. One can use this second method instead of the first one also if the patient's nose is not obstructed, provided that his nose be occluded by squeezing his nostrils with your hand after shifting it from his head. The patient's head must be kept bent backwards the most possible. Start with ten fast and deep expirations, then go on at the rhythm of twelve/fifteen expirations per minute. Continue as long as the patient has recovered consciousness, or a doctor has ascertained his death. 1.9 Burns As far as burns are concerned: Don't try to take off clothes from the burnt parts; Pour some cold water on body burnt areas and ask immediately for a doctor; Don't apply ointments or oily tinctures. SAFETY RULES Page 3 ENG ANNEX 1 When the equipment or the modules are equipped with the labels as shown here below, it is essential to observe the warnings contained -LIVE VOLTAGE POINT -PROTECTIVE EARTHING TERMINAL BLACK -CLASS 1 LASER PRODUCT BLACK BLACK YELLOW YELLOW BLACK EXPLANATORY LABEL (affixed to the WARNING LABEL (affixed to the CLASS 1 product side) CLASS 1 product front) Products which are of CLASS 1 as defined in the IEC EN 60825-1, fourth edition “Safety of laser products -Part 1: Equipment classification, requirements and user's guide”. Even if the product is of CLASS 1, please observe the following safety procedures, prescribed in the cited norm: • • • do not observe directly the laser beam, do not use observation optics (lens, microscopes, telescopes, etc.), do not expose eyes directly. SAFETY RULES Page 4 ENG -DEVICES SENSITIVE TO THE ELECTROSTATICS WARNING: Please observe the due precautions in handling devices which are sensitive to the electrostatics. -NON-SOLID ELECTROLYPTIC CAPACITORS MAY CONTAIN CHEMICALS TO BE REGARDED AS HAZARDOUS, IF INCORRECTLY HANDLED. WARNING THE MAXIMUM CAUTION IS REQUIRED IF THE OUTER CASE IS FRACTURED SAFETY RULES Page 5 ENG 2 2) STANDARDS 2.1. MANUFACTURE LABELS 2.1.1 BAR CODE LABEL Fig. 1 Label fields (ref. Fig.1): a) Serial number: this field contains the serial number (made up of a 7-digit sequential group) of the module or equipment. b) F (final test tracing out): this field contains an F letter that has been barred to certify that the item has been successfully tested in the factory Final Test Dept. c) Customer order reference. d) Equipment acronym or manufacture part number. e) ICS (Item Change Status): this field contains the item ICS, made up of 2 digits, starting from 01, of the manufacture part number or equipment. Fig.2 shows an example of bar code label applied: Fig. 2 On equipment other labels may be present, as integration of what reported in bar code label (fig.1); see following pages. STANDARDS Page 1 ENG 2.1.2 MANUFACTURE LABELS FOR RACK CABINETS AND EQUIPMENT (1) (4) (9) (5) (2) (6) (10) (3) (7) (8) (11) 90mm Fig. 3 Label fields (ref. Fig.3): (1) SYSTEM (it will be filled in only if the rack cabinet or the equipment belong to a system): this field contains the system acronym. (2) EQUIPMENT: This field contains the acronym of the rack cabinet or equipment. (3) MANUFACTURE PART NUMBER: This field contains the manufacture part number either of the rack cabinet or the equipment. (4) SERIAL NUMBER: This field contains the serial number (made up of a 5-digit sequential group) of the rack cabinet or equipment. The serial number of each item comes from the manufacture orders print-out (for domestic and foreign markets). (5) QIF (Quality Identification Factor): FACTORY USE ONLY (6) ICS (Item Change Status): This field contains the item ICS, made up of 2 digits, of the rack cabinet or equipment. (7) ORIGIN CODE: FACTORY USE ONLY (8) MANUFACTURE YEAR AND WEEK: This field contains the manufacture year and week of the rack cabinet or equipment (4 digits, the first two of which indicate the year, while the last two digits indicate the relevant week) e.g. 9515: 15th week of 1995. STANDARDS Page 2 ENG (9) SUPPLY VOLTAGE (from MAINS and/or from DC SOURCE) (10) ABSORBED CURRENT (11) MAINS FREQUENCY F (final test tracing out): This field contains an F letter that has been barred to certify that the item has been successfully tested in the factory Final Test Dept. Fig.4 shows an example of manufacture label as applied to a RACK CABINET or to an EQUIPMENT. 58822 230Vac/48Vdc 00021 01 0.5Aac/0.89Adc A0122 9515 50/60 Hz Fig. 4 (•) System acronym (if any) For instance, you will find the manufacture label placed: - on the upper left corner of the rack cabinet frame; - on the rear side (or on the external right side) of the equipment rack. STANDARDS Page 3 ENG 2.1.3 MANUFACTURE LABELS FOR RACKS AND PLUG-IN, OR WIRING TYPE, MODULES (1) (4) (5) (2) (6) (3) (7) (8) Fig. 5 Label fields (ref. Fig.5): (1) SYSTEM (it will be filled in only if the rack or the module to be label belong to a system): this field contains the system acronym. (2) EQUIPMENT: This field contains the acronym of the rack, or module. (3) MANUFACTURE PART NUMBER: This field contains the manufacture part number of the rack or module. (4) SERIAL NUMBER: This field contains the serial number (made up of a 5-digit sequential group) of the rack or module. The serial number of each item comes from the manufacture orders print-out (for domestic and foreign markets). (5) QIF (Quality Identification Factor) FACTORY USE ONLY (6) ICS (Item Change Status): This field contains the item ICS, made up of 2 digits, of the rack or module. (7) ORIGIN CODE: FACTORY USE ONLY (8) MANUFACTURE YEAR AND WEEK: This field contains the manufacture year and week of the rack or module (4 digits, the first two of which indicate the year, while the last two digits indicate the relevant week) e.g. 9515: 15th week of 1995. STANDARDS Page 4 ENG F (final test tracing out): This field contains an F letter that has been barred to certify that the item (rack or module) has been successfully tested in the factory Final Test Dept. Fig.6 shows an example of manufacture label as applied to a RACK or PLUG-IN, or WIRING TYPE MODULES. 58822 00021 01 A0122 9515 Fig. 6 (•) System acronym (if any) For instance, you will find the manufacture label placed: - on the topside of the plug-in module, right or left; - on the topside of the wiring-type module. 2.1.4 SUB-MODULES MANUFACTURE LABEL Fig. 7 Label fields (ref. Fig.7): (3) MANUFACTURE PART NUMBER: This field contains the sub-module manufacture part number. (5) QIF (Quality Identification Factor) FACTORY USE ONLY (6) ICS (Item Change Status): This field contains the item ICS, made up of 2 digits, of the sub-module. (7) ORIGIN CODE: FACTORY USE ONLY STANDARDS Page 5 ENG (8) MANUFACTURE YEAR AND WEEK: This field contains the manufacture year and week of the submodule (4 digits, the first two of which indicate the year, while the last two digits indicate the relevant week) e.g. 9542: 42nd week of 1995. F (final test tracing out): This field contains an F letter that has been barred to certify that the item (sub-module) has been successfully tested in the factory Final Test Dept. Fig. 8 shows an example of manufacture label as applied to a SUB-MODULE. 00081 01 B0111 F Fig. 8 You will find the manufacture label placed on the sub-module top, left, or right side. STANDARDS Page 6 ENG 2.2) SYMBOLS EQUIPMENT FRONT SYMBOLS SYMBOLS DESCRIPTION SYMBOLS SYMBOLS DESCRIPTION Earth connection Impulsive command Band-stop filter Ground Fuse Low-pass filter Chassis ground Thermal breaker High-pass filter AC Failure Modulator, demodulator DC Overtemperature Stereo Pulse current Output monitoring signal Balance Battery / accumulator Input monitoring signal Amplifier Direct power monitoring socket Adjustable gain amplifier Reflected power monitoring socket Loudspeaker connection Local oscillator monitoring socket Audio connection L.O. ON Gating as opening criterion Headphone connection STAND-BY Gating as closing criterion Stereo headphone ON push-button Channel / band filter Star connection Positive connector Negative connector OFF STANDARDS DESCRIPTION Page 7 ENG EQUIPMENT FRONT SYMBOLS SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION Delta connection Receiving antenna High voltage Linearization Start push-button Limiter upper threshold Local, manual command Limiter lower threshold Automatic Adjusting OFF / inhibited (function) Max adjusting ON / active (function) Min adjusting Stand-by (function) Adjusting Output connector Frequency adjusting SYMBOLS DESCRIPTION Dual sound Input connector Xtal adjusting 5MHz STANDARDS Clock display (operation time counter) Freq. tuning Fan, blower Amplitude tuning Antenna Band tuning Transmission antenna Mono Page 8 ENG BLOCK DIAGRAM SYMBOLS SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION Linear variability 2-way switch NAND general symbol Automatic adjustment Voltage control electromagnetic relay NOT general symbol Combiner general sign Transformer Preemphasis 2-way power divider Rectifier general symbol Deenphasis DC/DC converter Delay line general symbol 3-way power divider Bridge rectifier Coaxial type time delay limiter 4-way power divider Voltage regulator Resistive attenuator 2-way power combiner REG 3dB Hybrid Zener regulator Pad dB White limiter Constant current bias device LIM. Fixed phase shifter BIAS WHITE Positive peak clipper Sinusoidal oscillator THERMAL Thermal switch SWITCH STANDARDS Negative peak clipper Ex-OR Band-pass filter Circulator OR general symbol Band-stop filter Isolator NOR general symbol Low-pass filter Switch AND general symbol High-pass filter Page 9 ENG BLOCK DIAGRAM SYMBOLS SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION Divider by n DC amplifier Multiplier by n Differential comparator Mixer general symbol Phase comparator Up-converter from IF to RF Detector amplifier RF FI Down-converter from RF to IF SYMBOLS DESCRIPTION Optical amplifier f/n f/n FI OL RF OL P. SYNC CLAMP Lamped to the syncrhronizing signal peak Voltage / frequency converter Schmitt’s trigger Directional coupler Amplitude linearity precorrector Double directional coupler Amplitude limiter without distortion Directional coupler with double detector Equalizer general sign Detector Amplitude equalizer X3 Peak detector Phase equalizer To rise to cubical power Propagation time equalizer Amplifier general symbol Laser diode electricaloptical transmitter RF Multistage amplifier RF STANDARDS Optical-electrical receiver Page 10 ENG 3 3) GENERAL DESCRIPTION Mobile phone systems have increasingly been spreading in these last years. Besides providing reliable and good quality connections, telecommunication system services should cover as widest territory as possible. It is well-known that connections to users’ terminals are obtained on air by means of steady stations named radio bases, located through the whole territory so as to obtain a continuous covering through cells one next to another. That allows a great number of users to enter the system using few channels. It is important to maintain the continuity of radio-electrical coverage (and consequently, of service within each cell) in order to guarantee an acceptable level of communication. BTS Tri-cellular FIGURE 1 – SUBDIVISION OF THE TERRITORY IN CELLS Off-Air Repeaters are proposed as a valid and economical solution to optimize the cell coverage of the territory and irradiate dead spots as an alternative to solutions requiring dedicated Radio-Bases (Figure 2). MicroBTS solution Repeater solution 2Mbit radio connection BTS The repeater costs are 50% lower than with the μ BTS solution μBTS Repeater BTS Source Shadow Zone Shadow Zone FIGURE 2 – RADIO-ELECTRICAL PROBLEMS IN CELL NETWORK COVERAGE 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 3 Page 1 91 080 0716F – Rel.06 Off-Air Repeaters on one side receive the signals from the radio base station, amplify them and re-transmit them in the direction of the dead spot (down-link path). On the other side Off-Air Repeaters receive the signals from the mobiles (MS), amplify them and re- transmit them to the base station (up-link path). When a single Off-Air Repeater does not provide satisfactory coverage, the repeater can be used along with other equipment. Different solutions are provided: cascade systems, based on Bi-Directional Amplifiers, and optical fibre solutions, based on Remote Units. 3.1) EXAMPLE: USE IN TUNNELS The Off-Air Repeater interfaces directly with the BTS of the provider of the services to be extended, and can be used along with other equipment distributed inside the tunnels. Such equipment can be divided into two types, according to the radio-coverage system used: - Bi-directional amplifiers, for cascade systems. - Remote Units, for optical systems. The following are a few examples of general projects for radio-electric coverage in tunnels. • Tunnels with a length of less than 300 meters. In this case, one single Off-Air Repeater is sufficient. It is located at the entrance to the tunnel, equipped with an antenna which irradiates in the direction of the shadow zone (Figure 3). DO UP LI NK DOWN LI NK UP OFF-AIR REPEATER DOWN UP Power Supply (230Vac) 48Vdc Power Supply and external signals FIGURE 3 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 3 Page 2 91 080 0716F – Rel.06 • Tunnels with a length in the 300-meter to 600-meter range. Also in this case, one single Off-Air Repeater is sufficient. The repeater is located at the entrance to the tunnel and equipped with a leaky cable. This cable can be combined with a directional antenna to irradiate a portion of the area in front of the tunnel exit (Figure 4). DO UP LI NK DOWN LI NK UP OFF-AIR REPEATER DOWN UP Power Supply (230Vac) 48Vdc Power Supply and external signals FIGURE 4 • Tunnels with a length of more than 600 meters. The signal can be enhanced in two ways: a) By an Off-Air Repeater at the entrance to the tunnel, connected to a cascade of bi-directional amplifiers inside the tunnel which re-generate the signal with amplification steps at a distance of 250mt. ÷ 400mt. from one another (Figure 5). DO UP LI LI DOWN UP RF-DC-BF RF-DC-BF RF-DC-BF BI-DIRECTIONAL AMPLIFIER OFF-AIR REPEATER RF-DC-BF BI-DIRECTIONAL AMPLIFIER DOWN RF BF UP RF DC BF DC POWER SUPPLY RF-DC-BF Bias-T AMPLIFICATION STEP FIGURE 5 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 3 Page 3 91 080 0716F – Rel.06 b) By an Off-Air Repeater connected to master unit and optical remote units with amplification steps of no more than 1200mt. each. The optical fiber system extends the signal through an antenna or a passive distribution system (Figure 6). UP LI LI NK OFF-AIR REPEATER DOWN RF REMOTE UNIT DOWN UP UP Power Supply (230Vac) MASTER UNIT 48Vdc Power Supply and external signals FIGURE 6 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 3 Page 4 91 080 0716F – Rel.06 3.2) OPERATING PRINCIPLE – 800MHz/900MHz ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS The repeaters described in this handbook have been developed to permit cell coverage as set forth by SMR, CDMA/GSM/TDMA/AMPS, GSM-R and EGSM standards for cell phones. The DC powered repeaters (OR1) can be power-fed by a 48Vdc power supply source only. The AC powered repeaters (OR2) can be power-fed from MAINS (230Vac) or from a 48Vdc power supply source or both from MAINS and from a 48Vdc source. The presence of both power supply voltages guarantees the continuity of the coverage service even in case of failure of one source. The commutation is handled automatically by the repeater. Off-Air Repeaters are bi-directional amplifiers. The signal to be extended follows two distinct paths: the uplink path, from the mobiles to the radio base station, and the down-link path, from the radio base station towards the mobiles. Figure 7 provides the adjustable band Off-Air Repeaters block-diagram. NETWORK RS232 MANAGEMENT UNIT MODEM 48Vdc IN 230Vac IN 5.5Vdc 5.5Vdc 10.5Vdc DC/DC CONVERTER 48Vdc AC/DC CONVERTER MANAGEMENT BUS 5.5Vdc ALC 5.5Vdc 5.5Vdc LNA DOWN C1 5.5Vdc 10.5Vdc D1 BAND SELECTIVE 1 dB 10.5Vdc 10.5Vdc D2 BAND SELECTIVE 2 DOWN LINK HPA DOWN E1 DOWN LINK B1 B2 10.5Vdc 5.5Vdc 5.5Vdc DOWN DOWN BTS UP LINK UP E2 MS UP LINK UP HPA UP C2 LNA UP A2 dB A1 ALC FIGURE 7 – 800MHz/900MHz ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS BLOCK-DIAGRAM In down-link the RF signal from the donor antenna is filtered and pre-amplified by a low-noise amplifier (LNA, ref. C1). The selection of the band of frequencies to be extended is handled by two band-selective modules, ref. D1 and ref. D2, which make the band-pass and frequency center programmable entities. The band of frequencies to be extended can be managed by the user by means of the management system. The signal is then amplified by the High power amplifier (ref. E1) filtered by the MS side duplexer, ref. B2,and transmitted by an antenna or a passive distribution system. A VSWR detector is equipped. The up-link path is identical to the down-link path described above. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 3 Page 5 91 080 0716F – Rel.06 The 48Vdc powered repeater is equipped with a DC/DC converter, ref. F. The A.C. powered repeater is equipped also with an AC/DC converter, ref. L. Management module, ref. G, makes it possible to manage the repeater in remote mode via a built-in modem, or in local mode through the RS232 connector, available on the management module. The repeater management is performed by means of the Operation and Maintenance Terminal software both in local mode and in remote mode (ref. Chap. 4). 3.3) ATTACHED DOCUMENTS TECHNICAL CHARACTERISTICS SMR 48 Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS CDMA/GSM/TDMA/AMPS 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS EGSM 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS GSM-R 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS ILL SMR - CDMA/GSM/TDMA/AMPS OFF-AIR REPEATERS (ILLUSTRATIVE DRAWINGS) Sheet 1, equipment composition and backplane access points map Sheet 2, modules access points map and external access points map ILL EGSM OFF-AIR REPEATERS (ILLUSTRATIVE DRAWINGS) Sheet 1, equipment composition and backplane access points map Sheet 2, modules access points map and external access points map ILL GSM-R OFF-AIR REPEATERS (ILLUSTRATIVE DRAWINGS) Sheet 1, equipment composition and backplane access points map Sheet 2, modules access points map and external access points map 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 3 Page 6 91 080 0716F – Rel.06 ANNEX 1 TECHNICAL CHARACTERISTICS SMR 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS TECHNICAL CHARACTERISTICS Up Link operating frequency band Down Link operating frequency band Number of amplified bands Programmable Bandwidth / steps SMR ADJUSTABLE SMR ADJUSTABLE BANDWIDTH BANDWIDTH OFF-AIR REPEATER OFF-AIR REPEATER 48Vdc MODEL 230Vac MODEL 806MHz ÷ 824MHz 851MHz ÷ 869MHz Up to 16.5MHz, 10kHz step adjustable 26dBm (1 channel) 23dBm (2 channels) Output Power (CDMA) 20dBm (4 channels) 31dBm (1 channel) 27dBm (2 channels) Output Power (iDEN) 23dBm (4 channels) Noise Figure @ max. gain 8dB Gain 50dB up to 80dB / 1dB step Ripple into operating band ± 2dB Total processing delay 6μs Return Loss 14dB 3dB over nominal output power ALC threshold (default value) (this value can be changed on site) < -13dBm (in the frequency band 9kHz ÷ 1GHz) Spurious emissions and intermodulation products < -13dBm (in the frequency band 1GHz ÷ 12.75GHz) Local Control Interface RS232 Remote Control Interface GSM (850, 900, 1800, 1900) or CDMA (850, 1900) modem -72 ÷ -36Vdc Power Supply -72 ÷ -36Vdc 85÷265Vac (50-60Hz) Power Consumption 110W @ 48Vdc 140VA @ 230Vac Operating Temperature (*) -20°C up to +55°C Degree of protection provided by enclosure IP65 RF connectors 7/16 female 423x395x230mm Dimensions (h-w-d) (max. volume - heat sinks included) All values are typical at 25°C unless otherwise specified (*) Degraded performances from +50°C to +55° 800MHz Off-Air Repeaters (OR Series) TECHNICAL CHARACTERISTICS Annex 1 SMR ANNEX 2 TECHNICAL CHARACTERISTICS CDMA/GSM/TDMA/AMPS 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS CDMA/GSM/TDMA/AMPS CDMA/GSM/TDMA/AMPS ADJUSTABLE ADJUSTABLE BANDWIDTH BANDWIDTH TECHNICAL CHARACTERISTICS OFF-AIR REPEATER OFF-AIR REPEATER 48Vdc MODEL 230Vac MODEL Up Link operating frequency band 824MHz ÷ 849MHz Down Link operating frequency band 869MHz ÷ 894MHz Number of amplified bands Programmable Bandwidth / steps Up to 16.5MHz, 10kHz step adjustable 26dBm (1 channel) 23dBm (2 channels) Output Power (CDMA) 20dBm (4 channels) 31dBm (1 channel) 28dBm (2 channels) Output Power (GSM/TDMA/AMPS) 25dBm (4 channels) Noise Figure @ max. gain 8dB Gain 50dB up to 80dB / 1dB step Ripple into operating band ± 2dB Total processing delay 6μs Return Loss 14dB 3dB over nominal output power ALC threshold (default value) (this value can be changed on site) < -13dBm (in the frequency band 9kHz ÷ 1GHz) Spurious emissions and intermodulation products < -13dBm (in the frequency band 1GHz ÷ 12.75GHz) Local Control Interface RS232 Remote Control Interface GSM (850, 900, 1800, 1900) or CDMA (850, 1900) modem -72 ÷ -36Vdc Power Supply -72 ÷ -36Vdc 85÷265Vac (50-60Hz) Power Consumption 110W @ 48Vdc 140VA @ 230Vac Operating Temperature (*) -20°C up to +55°C Degree of protection provided by enclosure IP65 RF connectors 7/16 female 423x395x230mm Dimensions (h-w-d) (max. volume - heat sinks included) All values are typical at 25°C unless otherwise specified (*) Degraded performances from +50°C to +55°C 800MHz Off-Air Repeaters (OR Series) TECHNICAL CHARACTERISTICS Annex 2 CDMA/GSM/TDMA/AMPS ANNEX 3 TECHNICAL CHARACTERISTICS EGSM 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS TECHNICAL CHARACTERISTICS Up Link operating frequency band EGSM ADJUSTABLE EGSM ADJUSTABLE BANDWIDTH BANDWIDTH OFF-AIR REPEATER OFF-AIR REPEATER 48Vdc MODEL 230Vac MODEL 880MHz ÷ 915MHz 925MHz ÷ 960MHz Down Link operating frequency band Number of amplified bands Programmable Bandwidth / steps Up to 16.5MHz, 10kHz step adjustable Output Power 27dBm (2 carriers) Noise Figure @ max. gain 8dB Gain 50dB up to 80dB / 1dB step Ripple into operating band ± 2dB Total processing delay Return Loss ALC threshold (default value) Spurious emissions and intermodulation products Local Control Interface 6μs 14dB 3dB over nominal output power (this value can be changed on site) < -36dBm (in the frequency band 9kHz ÷ 1GHz) < -30dBm (in the frequency band 1GHz ÷ 12.75GHz) RS232 Remote Control Interface PSTN – GSM/DCS modem -72 ÷ -36Vdc 85÷265Vac (50-60Hz) 140VA @ 230Vac -72 ÷ -36Vdc Power Supply Power Consumption 110W @ 48Vdc Operating Temperature (*) -20°C up to +55°C Degree of protection provided by enclosure IP65 RF connectors 7/16 female 423x395x230mm (max. volume - heat sinks included) Dimensions (h-w-d) All values are typical at 25°C unless otherwise specified (*) Degraded performances from +50°C to +55°C 900MHz Off-Air Repeaters (OR Series) TECHNICAL CHARACTERISTICS Annex 3 EGSM ANNEX 4 TECHNICAL CHARACTERISTICS GSM-R 48Vdc/230Vac ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS TECHNICAL CHARACTERISTICS Up Link operating frequency band GSM-R ADJUSTABLE GSM-R ADJUSTABLE BANDWIDTH BANDWIDTH OFF-AIR REPEATER OFF-AIR REPEATER 48Vdc MODEL 230Vac MODEL 876MHz ÷ 880MHz 921MHz ÷ 925MHz Down Link operating frequency band Number of amplified bands Programmable Bandwidth / steps Up to 4MHz, 10kHz step adjustable Output Power 27dBm (2 carriers) Noise Figure @ max. gain 8dB Gain 50dB up to 80dB / 1dB step Ripple into operating band ± 2dB Total processing delay Return Loss ALC threshold (default value) Spurious emissions and intermodulation products Local Control Interface 6μs 14dB 3dB over nominal output power (this value can be changed on site) < -36dBm (in the frequency band 9kHz ÷ 1GHz) < -30dBm (in the frequency band 1GHz ÷ 12.75GHz) RS232 Remote Control Interface PSTN – GSM/DCS modem -72 ÷ -36Vdc 85÷265Vac (50-60Hz) 140VA @ 230Vac -72 ÷ -36Vdc Power Supply Power Consumption 110W @ 48Vdc Operating Temperature (*) -20°C up to +55°C Degree of protection provided by enclosure IP65 RF connectors 7/16 female 423x395x230mm (max. volume - heat sinks included) Dimensions (h-w-d) All values are typical at 25°C unless otherwise specified (*) Degraded performances from +50°C to +55°C 900MHz Off-Air Repeaters (OR Series) TECHNICAL CHARACTERISTICS Annex 4 GSM-R L E2 E1 EQUIPMENT COMPOSITION Ref. LNA +5V HPA RS232 OUT ALARM POWER SUPPLY 925-960MHz 10V5 880-915MHz 5V5 LNA DOWN Out In UP-LINK Out DOWN-LINK In ANT DOWN-LINK ANT BAND-SELECTIVE 2 In Out BAND-SELECTIVE 1 In B1 LNA UP C1 A1 A2 DIRECTIONAL COUPLER WITH RETURN LOSS METER C2 A2 D1 D2 DUPLEXER FILTER C1 DOWN LINK LNA MODULE C2 UP LINK LNA MODULE D1 BAND SELECTIVE MODULE BS1 D2 BAND SELECTIVE MODULE BS2 E1 FFWD HIGH POWER AMPLIFIER (DOWN LINK PATH) E2 FFWD HIGH POWER AMPLIFIER (UP LINK PATH) DC/DC CONVERTER BACKPLANE REPEATER BOX AC/DC CONVERTER (230VAC MODEL ONLY) OPEN DOOR DETECTOR MANAGEMENT MODULE 132kHz CARD (OPTION - to be equipped when the repeater is connected to bi-directional amplifiers) 880-915MHz 925-960MHz Out UP-LINK DOUBLE DIRECTIONAL COUPLER B1-B2 SPV BUS HIGH POWER AMPLIFIER DOWN LINK SPV BUS HIGH POWER AMPLIFIER UP LINK BS 1 RL OPERATING OUT IN IN BS 2 132KHz DESCRIPTION A1 B2 INTERNAL VIEW - EQUIPMENT COMPOSITION BACKPLANE ACCESS POINTS MAP 13 12 11 10 CONNECTORS Ref. Connector type 15-pole D-Sub female Band selective Module 2 15-pole D-Sub female LNA (Up Link path) 15-pole D-Sub female Band selective Module 1 10-way female terminal block External alarms and signals 2-way female terminal block Open door sensor 3-way female terminal block Return Loss meter 15-pole D-Sub female DC/DC converter 10 15-pole D-Sub female HPA (Down Link path) 11 2-way female terminal block (230VAC MODEL ONLY) AC/DC converter (50.5Vdc backplane input) 12 15-pole D-Sub female Management module 13 15-pole D-Sub female Ref. DESCRIPTION GREEN LED: ON when 10.5Vdc is available GREEN LED: ON when 5.5Vdc is available Part Number ILL EGSM OFF-AIR REPEATERS HPA (Down Link path) LEDs Connected to Date Title EGSM ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS COMPOSITION AND BACKPLANE ACCESS POINTS MAP ED. 02 17/01/2007 Drawn by Checked by INTERNAL VIEW - BACKPLANE Scale Copyright protection according to law Revisions ED. 01 03/11/2006 Approved by CG MN AV Sheet 1/2 43 42 41 40 39 38 37 36 35 34 33 MODULES ACCESS POINTS MAP 30 Ref. 10 11 12 13 14 15 16 17 18 21 22 23 24 25 26 LNA +5V HPA RS232 OPERATING ALARM SPV BUS BS 1 RL HIGH POWER AMPLIFIER DOWN LINK SPV BUS HIGH POWER AMPLIFIER UP LINK 46 31 IN IN BS 2 132KHz 32 44 45 48 OUT OUT 47 POWER SUPPLY 49 29 10V5 5V5 28 26 925-960MHz 27 51 880-915MHz 50 LNA DOWN Out UP-LINK 27 25 28 In 29 24 Out Out DOWN-LINK In ANT DOWN-LINK ANT BAND-SELECTIVE 2 In 23 30 31 32 33 34 BAND-SELECTIVE 1 925-960MHz UP-LINK Out 880-915MHz In LNA UP 35 36 57 1 9 10 11 12 13 14 15 16 17 18 21 37 22 38 INTERNAL VIEW - MODULES ACCESS POINTS 39 40 41 42 43 44 45 46 47 48 49 50 51 57 (*) 52 53 54 (*) 55 56 DESCRIPTION DUPLEXER - BTS side - Up Link path SMA connector LNA - Down Link - input Band Selective 2 Up-Link path output DUPLEXER - BTS side - input/output SMA connector D irectional coupler - BTS side - SMA (f) input/output connector DUPLEXER - BTS side - SMA Down Link connector LNA - Up Link path - output Band Selective 1 Up Link Input Band Selective 1 Down Link Output Band Selective 2 Down Link Input LNA - Down Link path - output LNA - Up Link path - input Band Selective 2 Up Link path input Band Selective 2 Down Link path output Band Selective 1 Down Link path Input Band Selective 1 Up Link path output DUPLEXER - MS side - Up Link path SMA connector 48Vdc ONLY circuit breaker DUPLEXER - MS side - input/output SMA connector D irectional coupler - MS side - SMA (f) input/output connector DUPLEXER - MS side - Down Link path SMA connector GREEN LED: +5Vdc available HPA - UP LINK - communicates with management GREEN unit GREEN / RED LED HPA UP HPA - UP LINK - does not communicate with RED management unit GREEN LED: +10.5V available HPA - DOWN LINK - communicates with GREEN management unit GREEN / RED LED HPA DOWN HPA - DOWN LINK - does not communicate with RED management unit HPA Down Link output Sub-D 15-pole management link between Down Link HPA and management unit HPA Down Link input HPA Down Link monitoring SMA connector Sub-D 9-poles RS232 connector LNA - DOWN LINK - communicates with GREEN management unit GREEN / RED LED LNA DOW N LNA - DOW N - does not communicate with RED management unit LNA - UP LINK - communicates with management GREEN unit GREEN / RED LED LNA UP LNA - UP LINK - does not communicate with RED management unit GREEN BS1 communicates with management unit GREEN / RED LED Band Selective 1 RED BS1 does not communicate with management unit Sub-D 15-pole management link between Down Link HPA and management unit GREEN BS2 communicates with management unit GREEN / RED LED Band Selective 2 RED BS2 does not communicate with management unit GREEN LED 132kHz: 132kHz (line am p lifier management carrier) correctly operating RED LED: Return Loss alarm Sub-D 15-pole management link between Up Link HPA and management unit Sub-D 15-pole management link between Up Link HPA and management unit HPA Up Link input HPA Up Link monitoring SMA connector GSM modem RF output HPA Up Link output RED ON Trying to connect to network RED LED: modem BLINKING operation Modem correctly operating RED GREEN LED: equipment correctly operating GREEN LED: 5.5V available RED LED: equipment fault AC MAINS circuit breaker EXTERNAL ACCESS POINTS MAP BTS side 7/16 RF connector Equipment Grounding AC voltage input (230Vac) 48Vdc input / external alarms Connector MS side 7/16 RF connector (*) 230VAC MODEL ONLY Part Number ILL EGSM OFF-AIR REPEATERS 52 53 54 55 56 BOTTOM VIEW - REPEATER CASE CLOSED EXTERNAL ACCESS POINTS Scale Copyright protection according to law Title Date EGSM ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS MODULES ACCESS POINTS MAP AND EXTERNAL ACCESS POINTS MAP Revisions ED. 01 03/11/2006 ED. 02 17/01/2007 Drawn by Checked by Approved by CG MN AV Sheet 2/2 L E2 E1 EQUIPMENT COMPOSITION Ref. LNA +5V HPA RS232 OUT ALARM POWER SUPPLY 921-925MHz 10V5 876-880MHz 5V5 LNA DOWN Out In UP-LINK 921-925MHz Out ANT DOWN-LINK Out DOWN-LINK In 876-880MHz ANT BAND-SELECTIVE 2 In BAND-SELECTIVE 1 In Out UP-LINK DOUBLE DIRECTIONAL COUPLER A2 DIRECTIONAL COUPLER WITH RETURN LOSS METER B1-B2 SPV BUS HIGH POWER AMPLIFIER DOWN LINK SPV BUS HIGH POWER AMPLIFIER UP LINK BS 1 RL OPERATING OUT IN IN BS 2 132KHz DESCRIPTION A1 DUPLEXER FILTERS C1 DOWN LINK LNA MODULE C2 UP LINK LNA MODULE D1 BAND SELECTIVE MODULE BS1 D2 BAND SELECTIVE MODULE BS2 E1 FFWD HIGH POWER AMPLIFIER (DOWN LINK PATH) E2 FFWD HIGH POWER AMPLIFIER (UP LINK PATH) DC/DC CONVERTER BACKPLANE REPEATER BOX AC/DC CONVERTER (230VAC MODEL ONLY) OPEN DOOR DETECTOR MANAGEMENT MODULE 132kHz CARD (OPTION - to be equipped when the repeater is connected to bi-directional amplifiers) LNA UP B1 C1 A1 C2 A2 D1 D2 B2 INTERNAL VIEW - EQUIPMENT COMPOSITION BACKPLANE ACCESS POINTS MAP 13 12 11 10 CONNECTORS Ref. 15-pole D-Sub female Band selective Module 2 15-pole D-Sub female LNA (Up Link path) 15-pole D-Sub female Band selective Module 1 10-way female terminal block External alarms and signals 2-way female terminal block Open door sensor 3-way female terminal block Return Loss meter 15-pole D-Sub female DC/DC converter 10 15-pole D-Sub female HPA (Down Link path) 11 2-way female terminal block (230VAC MODEL ONLY) AC/DC converter (50.5Vdc backplane input) 12 15-pole D-Sub female Management module 13 15-pole D-Sub female Ref. DESCRIPTION GREEN LED: ON when 10.5Vdc is available GREEN LED: ON when 5.5Vdc is available Part Number ILL GSM-R OFF-AIR REPEATERS HPA (Down Link path) LEDs Connected to Connector type Date Title GSM-R ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS COMPOSITION AND BACKPLANE ACCESS POINTS MAP ED. 02 17/01/2007 Drawn by Checked by INTERNAL VIEW - BACKPLANE Scale Copyright protection according to law Revisions ED. 01 21/11/2006 Approved by CG MN AV Sheet 1/2 43 42 41 40 39 38 37 36 35 34 33 MODULES ACCESS POINTS MAP 30 Ref. 10 11 12 13 14 15 16 17 18 21 22 23 24 25 26 LNA +5V HPA RS232 OPERATING ALARM SPV BUS BS 1 RL HIGH POWER AMPLIFIER DOWN LINK SPV BUS HIGH POWER AMPLIFIER UP LINK 46 31 IN IN BS 2 132KHz 32 44 45 48 OUT OUT 47 POWER SUPPLY 49 29 10V5 5V5 28 26 921-925MHz 27 51 876-880MHz 50 LNA DOWN Out UP-LINK In DOWN-LINK Out Out DOWN-LINK In 23 29 24 BAND-SELECTIVE 1 UP-LINK 28 ANT In In 25 30 31 32 33 34 876-880MHz 921-925MHz ANT BAND-SELECTIVE 2 27 Out LNA UP 35 36 37 57 1 9 10 11 12 13 14 15 16 17 18 21 22 38 39 INTERNAL VIEW - MODULES ACCESS POINTS 40 41 42 43 44 45 46 47 48 49 50 51 57 (*) 52 53 54 (*) 55 56 D E S C R IPTION DUPLEXER - BTS side - Up Link path SMA connector LNA - Down Link - input Band Selective 2 Up-Link path output DUPLEXER - BTS side - input/output SMA connector D irectional coupler - BTS side - SMA (f) input/output connector DUPLEXER - BTS side - SMA Down Link connector LNA - Up Link path - output Band Selective 1 Up Link Input Band Selective 1 Down Link Output Band Selective 2 Down Link Input LNA - Down Link path - output LNA - Up Link path - input Band Selective 2 Up Link path input Band Selective 2 Down Link path output Band Selective 1 Down Link path Input Band Selective 1 Up Link path output DUPLEXER - MS side - Up Link path SMA connector 48Vdc ONLY circuit breaker DUPLEXER - MS side - input/output SMA connector D irectional coupler - MS side - SMA (f) input/output connector DUPLEXER - MS side - Down Link path SMA connector GREEN LED: +5Vdc available HPA - UP LINK - communicates with management GREEN unit G R E E N / RED LED HPA UP HPA - UP LINK - does not communicate with RED management unit GREEN LED: +10.5V available HPA - DOWN LINK - communicates with GREEN management unit G R E E N / RED LED HPA DOW N HPA - DOWN LINK - does not communicate with RED management unit HPA Down Link output Sub-D 15-pole management link between Down Link HPA and management unit HPA Down Link input HPA Down Link monitoring SMA connector Sub-D 9-poles RS232 connector LNA - DOWN LINK - communicates with GREEN management unit G R E E N / RED LED LNA DOW N LNA - DOW N - does not communicate with RED management unit LNA - UP LINK - communicates with management GREEN unit G R E E N / RED LED LNA UP LNA - UP LINK - does not communicate with RED management unit GREEN BS1 communicates with management unit G R E E N / RED LED Band Selective 1 RED BS1 does not communicate with management unit Sub-D 15-pole management link between Down Link HPA and management unit GREEN BS2 communicates with management unit G R E E N / RED LED Band Selective 2 RED BS2 does not communicate with management unit GREEN LED 132kHz: 132kHz (line amplifier management carrier) correctly operating RED LED: Return Loss alarm Sub-D 15-pole management link between Up Link HPA and management unit Sub-D 15-pole management link between Up Link HPA and management unit HPA Up Link input HPA Up Link monitoring SMA connector GSM modem RF output HPA Up Link output RED ON Trying to connect to network RED LED: modem BLINKING operation Modem correctly operating RED GREEN LED: equipment correctly operating GREEN LED: 5.5V available RED LED: equipm e n t fault AC MAINS circuit breaker EXTERNAL ACCESS POINTS M A P BTS side 7/16 RF connector Equipment Grounding AC voltage input (230Vac) 48Vdc input / external alarms Connector MS side 7/16 RF connector (*) 230VAC MODEL ONLY Part Number ILL GSM-R OFF-AIR REPEATERS 52 53 54 55 56 BOTTOM VIEW - REPEATER CASE CLOSED EXTERNAL ACCESS POINTS Scale Copyright protection according to law Title Date GSM-R ADJUSTABLE BANDWIDTH OFF-AIR REPEATERS MODULES ACCESS POINTS MAP AND EXTERNAL ACCESS POINTS MAP Revisions ED. 01 21/11/2006 ED. 02 17/01/2007 Drawn by Checked by Approved by CG MN AV Sheet 2/2 4 4) INSTALLATION AND POWER-UP PROCEDURES Ref.: ILL SMR - CDMA/GSM/TDMA/AMPS - R-GSM - EGSM OFF-AIR REPEATERS WARNING: Before installing the equipment, carefully read the safety norms herewith attached. A correct repeater installation and setting procedure requires a good knowledge and experience in installing telecommunication equipment. These activities should be performed by skilled personnel only. Remember that if the equipment is not installed correctly, it may: - put the donor BTS temporary out of service, - be damaged by excessively high input or output signal levels. 4.1) INSTALLATION 1. INITIAL CHECK Make sure that the supply is complete and/or that the material has not been damaged during transport. The list of the materials that make up the equipment is described in the relative PACKING LIST. Should any parts be missing, or should some be damaged, kindly inform the Sales Dept. of RFS immediately, in order to facilitate replacing and/or repairing the parts involved. 10V5 DOWN-LINK DOWN-LINK UP-LINK In Out Out In In UP-LINK BAND-SELECTIVE 2 In Out Out In Out DOWN-LINK In DOWN-LINK BAND-SELECTIVE 1 LNA UP AC voltage circuit breaker ref. 59 SPV BUS 10V5 BAND-SELECTIVE 1 In HIGH POWER AMPLIFIER DOWN LINK SPV BUS POWER SUPPLY 5V5 BAND-SELECTIVE 2 Out LNA DOWN UP-LINK In LNA HPA ALARM LNA DOWN Out BS 1 OUT POWER SUPPLY 5V5 IN IN OUT ALARM RL +5V OPERATING OUT SPV BUS LNA HPA HIGH POWER AMPLIFIER UP LINK 132KHz HIGH POWER AMPLIFIER DOWN LINK SPV BUS HIGH POWER AMPLIFIER UP LINK BS 2 BS 1 RL +5V OPERATING OUT IN IN BS 2 132KHz WARNING: Before installing the equipment, always make sure that the repeater is not powered up: Check that both ON/OFF switches located inside the alternate current powered repeater are in the OFF position (AC voltage circuit breaker, ref. 59 and 48Vdc circuit breaker, ref. 22 FIGURE 1a). Check that the ON/OFF switch (48Vdc circuit breaker, ref. 22, FIGURE 1b) located inside the direct current powered repeater is in the OFF position. The LEDs inside the repeater must be turned off. UP-LINK Out LNA UP 48Vdc circuit breaker ref. 22 48Vdc circuit breaker ref. 22 a) 230Vac MODEL INTERNAL VIEW b) 48Vdc MODEL INTERNAL VIEW FIGURE 1 – EQUIPMENT POWER SWITCHES 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 1 91 080 0716F – Rel.06 2. POSITIONING THE REPEATER The Off-Air Repeater is housed inside a case which provides high-degree environmental protection (IP65). Therefore it is suitable for outdoor wall mount installation. It can also be installed inside specific cabinets equipped with UPS units. Fix the Off-Air Repeater in vertical position on the wall, or on the vertical guides present inside the cabinet: • Lift the equipment and fix its position with four M8 bolts, which are to be inserted in the pre-cut slots (ref. A, FIGURE 2). • After checking the correct positioning of the equipment, fully tighten the bolts. 334.00 mm (13.15 in.) 366.00 mm (14.41 in.) FIGURE 2 - POSITION OF THE HOLES IN THE SUPPORT BRACKETS FOR THE EQUIPMENT 3. POWER SUPPLY SOURCE CONNECTIONS AND ALARMS CONNECTIONS • Before carrying out any other electrical connection connect the rack to the station ground, using the ground bolt on the bottom of the repeater (ref. 53, FIGURE 3). • Make sure that the power supply source provides the prescribed nominal voltage. If so, connect the equipment to the power supply source, as described below. MS side RF connector ref. 56 MS side RF connector ref. 56 BTS side RF connector ref. 52 BTS side RF connector ref. 52 Equipment Grounding ref. 53 AC voltage input from MAINS ref. 54 48Vdc input and external alarms Connector ref. 55 Equipment Grounding ref. 53 a) 230Vac MODEL BOTTOM VIEW 48Vdc input and external alarms Connector ref. 55 b) 48Vdc MODEL BOTTOM VIEW FIGURE 3 – EXTERNAL CONNECTORS 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 2 91 080 0716F – Rel.06 • D.C. POWERED EQUIPMENT Connect the 15-pole (f) connector on the bottom of the repeater (ref. 55, FIGURE 3) to the 48Vdc/Alarm cable (supplied with the equipment). The cable permits D.C power supply (48Vdc) to the equipment. It also makes available the remote signals detailed into Table 1. Connect the cable to the power supply source (48Vdc) and connect the external signals. PLEASE NOTE: The 48Vdc power supply cable (also including the external alarms), provided standard with the equipment, must never be longer than 3 meters in length (connectors included). 48Vdc POWER SUPPLY AND EXTERNAL ALARMS CONNECTOR PIN TYPE OF SIGNAL 48Vdc POWER SUPPLY EXTERNAL ALARMS 10 11 12 13 14 WIRES COLOR OF 48VDC POWER SUPPLY AND EXTERNAL ALARMS CABLE 0Vdc 0Vdc - 48Vdc - 48Vdc EXTERNAL ALARM 3 EXTERNAL ALARM 4 EXTERNAL ALARM 2 EXTERNAL ALARM 1 GROUND - GND +5Vdc EXT. ALM. COMMON NOT CONNECTED SPV CARRIER FOR BDAs (IF ANY) NOT CONNECTED NOT CONNECTED 132kHz RED RED BLACK BLACK GRAY BROWN ORANGE PINK GREEN WHITE BLUE VIOLET TABLE 1 – 48Vdc POWER SUPPLY AND REMOTE SIGNALS CONNECTOR PIN-OUT 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 3 91 080 0716F – Rel.06 • AC POWERED EQUIPMENT (ALTERNATE CURRENT) Connect the 230Vac power cable to the connector located on the bottom of the repeater (ref. 54, FIGURE 3). The connector pin assignments are detailed in Table 2. 230Vac POWER SUPPLY CONNECTOR PIN CABLE 230VAC POWER SUPPLY CABLE COLOR LINE NEUTRAL GROUND (GND) NOT CONNECTED BROWN BLUE YELLOW / GREEN TABLE 2 – 230Vac POWER SUPPLY CONNECTOR PIN-OUT Connect the other end of the cable to the power supply source (230Vac). Also connect the 48Vdc power and alarms cable, provided standard, to the 15-pin connector located on the bottom of the equipment (ref. 55, FIGURE 3). The cable makes remote signals available. The connector pin-out is detailed into table 1. The cable can also be connected to a 48Vdc power supply, to feed the equipment with a D.C. voltage. PLEASE NOTE: The 48Vdc power supply cable (also including the external alarms), provided standard with the equipment, must never be longer than 3 meters in length (connectors included). 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 4 91 080 0716F – Rel.06 4.2) POWER-UP Warning: before power up, make sure that the isolation between the donor antenna and the service antenna is at least 15dB greater than the repeater gain. 1. 2. 3. Connect the cable from the donor antenna to a spectrum analyzer and check input signal presence and level. After measurement disconnect the spectrum analyzer. Switch on the equipment by means of the switches placed inside the repeater (FIGURE 1a and b). Check the LEDs status on the management module: FIGURE 4 and Table 3 show LEDs status on the management module under normal operating conditions. 11S 10S 9S 8S 7S 6S BS 2 132KHz BS 1 RL LNA +5V HPA OPERATING ALARM 1S 2S 3S 4S 5S FIGURE 4 – MANAGEMENT MODULE: LEDS STATUS - CORRECT POWER UP REF. LED 1S LED 2S LED 3S STATUS OFF ON ON MEANING LED 4S ON, GREEN LED 5S ON, GREEN LED 6S ON, GREEN LED 7S LED 8S ON, GREEN ON, GREEN LED 9S ON, GREEN LED 10S ON, GREEN 132kHz correctly operating LED 11S OFF NO Return Loss alarm Equipment correctly operating Management module: +5Vdc available HPA (High Power Amplifier) - UP LINK communicates with management module HPA (High Power Amplifier) - DOWN LINK communicates with management module LNA (Low Noise Amplifier) - DOWN LINK communicates with management module BS1 communicates with management module BS2 communicates with management module LNA (Low Noise Amplifier) - UP LINK - communicates with management module TABLE 3 - MANAGEMENT MODULE: LEDS STATUS - CORRECT POWER UP 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 5 91 080 0716F – Rel.06 4. 5. Check that the green LED on the 230Vac power supply module (when equipped) is ON. Check LEDs status on the 48Vdc power supply module: FIGURE 5 and Table 4 show LEDs status on the power supply module (DC/DC converter) under normal operating conditions. POWER SUPPLY 5V5 10V5 1A 2A FIGURE 5 – DC/DC CONVERTER: LEDS STATUS - CORRECT POWER UP REF. LED 1A LED 2A STATUS ON ON MEANING 5.5Vdc from DC/DC converter available 10.5Vdc from DC/DC converter available TABLE 4 - DC/DC CONVERTER: LEDS STATUS - CORRECT POWER UP 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 6 91 080 0716F – Rel.06 6.WIRELESS MODEMS a. Models equipped with CDMA modem data communication between repeater (via built-in CDMA modem) and management workstation (PC where OMT/OMC management softwares have been previously installed) via PSTN and/or CDMA modem, must be established in CSD (CIRCUIT-SWITCHED DATA) mode only. All other modalities are not allowed. As CDMA modems don’t use SIMs, the network’s parameters have to be set manually by using the HyperTerminal. Please contact your local Operator, communicating modem’s ESN (check the sticker at the top of the management module), to get the needed parameters. Most common parameters are: Typical CDMA Network Parameters Acronyms Full name Network's setting / Terminal's setting Description Notes MSL Master Subsidy Lockcode Provided by the Operator Modem lock / unlock code MDN Mobile Data Number Provided by the Operator Modem phone number MDN & MTN are synonyms MTN Mobile Telephone Number Provided by the Operator Modem phone number MDN & MTN are synonyms MNC Mobile Network Code Provided by the Operator 2 digit number that represents a sub-network in the IMSI MCC Mobile Country Code Provided by the Operator Predefined number that represents a Country in the IMSI ESN Electronic Serial Number Proprietary of the modem (factory setting) Modem internal proprietary ID (factory setting) It can be found into the sticker at the top of the management module MIN Mobile Identification Number Provided by the Operator Subscriber's account number IMSI International Mobile Subscription Identity Provided by the Operator International modem ID IMSI = MCC + MNC + MIN (Home) SID System ID Provided by the Operator (Home) NID Network ID Provided by the Operator PRI Product Release Instruction Provided by the Operator Carrier information PRL Preferred Roaming List Provided by the Operator List of NIDs/SIDs ID of the sub-network where modem can operate ID of the sub-network where modem can operate SID & NID are synonyms SID & NID are synonyms PCA Primary Channel A Provided by the Operator RF primary channel PCB Primary Channel B Provided by the Operator RF primary channel SCA Secondary Channel A Provided by the Operator RF secondary channel SCB Secondary Channel B Provided by the Operator RF secondary channel A-key Autenthification key Provided by the Operator Key for the autenthification Built-in modem's one is random Note: not all parameters could be needed In normal operating conditions the jumper must remain connected (if removed, the remote management will be avoided). It can be temporary removed to set the Operator’s parameters into the built-in modem by using the RS232 modem port. The same serial cable used for local management, can be used to set the modem. Once the modem setting is complete, reconnect the jumper to the normal operating position. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 7 91 080 0716F – Rel.06 The following procedure explains how to set the modem’s parameters. Please note: AT commands, contained between the inverted commas, must be strictly typed as it follows. 1) 2) 3) 4) 5) Switch-off the repeater Remove the jumper at RS232 (modem) connector Connect the serial cable (supplied with repeater) with your laptop and RS232 (modem) connector Switch-on the repeater and wait for the complete auto-diagnostic test Run HyperTerminal software on your laptop (if you’re using Microsoft XP, run HyperTerminal from start/programs/accessories/communication/HyperTerminal) 6) Type the connection’s name (e.g. repeater’s modem) and press OK 7) Chose the right PC’s serial port (COM) and press OK 8) Set the bit-rate at “9600” baud 9) Set the number of bits at “8” 10) Set the parity at “no parity” 11) Set the bit stop at “1” 12) Set the flow control at “no flow control” 13) Press OK 14) Type “AT” and press ENTER (modem should reply with “OK”) 15) Type “AT+E1” and press ENTER (modem should reply with “OK”) 16) Type “AT+CGSN” and press ENTER to display the ESN number (if needed) 17) Type “AT+WSPC=1,000000” and press ENTER to get access to CDMA AT commands 18) Type “AT+WMDN=xxx” where xxx is the MDN number (10 to 15 digits) and press ENTER If needed, to get current MDN number, type “AT+WMDN?” and press ENTER 19) Type “AT+WIMI=xxx” where xxx is the IMSI number (15 digits) and press ENTER If needed, to get current IMSI number, type “AT+WIMI? and press ENTER 20) Type “AT+WSID=, xxx, yyy” where xxx is the SID number (1 up to 5 digits / 0 up to 32767) and yyy is the NID number (1 up to 5 digits / 0 up to 65535 – if not provided, set 65535) and press ENTER If needed, to get current IMSI number, type “AT+WIMI? and press ENTER With the this command you’ve set SID & NID number in first memory location. Up to 20 (0 up to 19) locations are supported. To set other SIDs & NIDs, please use the following sintax: Type “AT+WSID=zz, xxx, yyy” where zz is the location (up to 2 digits / 1 up to 19) where these SIDs & NIDs have to be stored, xxx is the SID number (1 up to 5 digits / 0 up to 32767) and yyy is the NID number (1 up to 5 digits / 0 up to 65535 – if not provided, set 65535) and press ENTER Please note: to set both SID & NID at 0 in location 2, type “AT+WSID=2” 21) Type “AT+WPCC=xxx,yyy” where xxx is primary channel “a” (up to 4 digits / 0 up to 2047) and yyy is primary channel “b” (up to 4 digits / 0 up to 2047) and press ENTER If needed, to get current primary channels, type “AT+WPCC? and press ENTER 22) Type “AT+WSCC=xxx,yyy” where xxx is secondary channel “a” (up to 4 digits / 0 up to 2047) and yyy is secondary channel “b” (up to 4 digits / 0 up to 2047) and press ENTER If needed, to get current secondary channels, type “AT+WSCC? and press ENTER 23) Type “AT+WCMT=1” and press ENTER to store these settings into the modem. The modem will be automatically re-start with new settings. Please wait for 10-20 seconds prior to type other commands 24) Type “AT” and press ENTER (modem should reply with “OK”) 25) Type “AT+E1” and press ENTER (modem should reply with “OK”) 26) Type “AT+CICB=0” and press ENTER to allow CSD data connections 27) Close the HyperTerminal 28) Remove the serial cable 29) Switch-off the equipment 30) Reconnect the existing jumper cable with RS232 (modem) Please note: not all the above mentioned parameters could be necessary. For any problem, please contact our local subsidiary. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 8 91 080 0716F – Rel.06 b. Models equipped with GSM modem How to install/remove the SIM card from the built-in modem • Open the repeater. • Check that the switches inside the repeater are set to 0 - OFF (FIGURE 1a and b). • Insert the SIM enabled to data transmission in not transparent mode 9600BPS (FIGURE 6) FIGURE 6 – DETAIL OF THE SIM INSERTION • Close the Management Module • Switch on the equipment (AC voltage circuit breaker, ref. 59, 48Vdc circuit breaker, ref. 22, FIGURE 1a-b). • Close the repeater. 7. INSTALL THE OPERATION AND MAINTENANCE SOFTWARE OMT REPEATER Install on your PC the Operation and Maintenance Terminal software to set and manage the equipment (please refer to the software User’s manual). The repeater can be managed in remote mode via a built-in modem, or in local mode. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 9 91 080 0716F – Rel.06 START OMT Repeater IN LOCAL MODE In LOCAL mode the notebook is connected to the repeater via RS232 serial cable. - Open the repeater door (by unscrewing four screws located on the equipment front door). Connect your notebook to the management module (connector RS232, ref. 34, FIGURE 7) using the provided serial cable (null-modem type). RS232 Link ref. 59 LNA HPA RS232 (Repeater) SPV BUS BS 1 RL +5V OPERATING OUT OUT ALARM POWER SUPPLY 5V5 IN RS232 Repeater ref. 34 SPV BUS IN BS 2 132KHz HIGH POWER AMPLIFIER UP LINK RS232 (Modem) RS232 Modem ref. 58 HIGH POWER AMPLIFIER DOWN LINK 8. 10V5 LNA DOWN Out UP-LINK In BAND-SELECTIVE 2 In DOWN-LINK Out DOWN-LINK Out In BAND-SELECTIVE 1 In UP-LINK Out LNA UP FIGURE 7 – RS232 CONNECTORS The connector RS232 (ref. 58,FIGURE 7) and the connector RS232 (ref. 59, FIGURE 7) are connected with a cable (only in models equipped with CDMA modem). Switch on your notebook and start Windows To Run the program select the related folder in the Windows ‘Start’ menu and click. The ‘Login panel’ is displayed (FIGURE 8). FIGURE 8 – LOGIN PANEL Select read/write user. PLEASE NOTE It’s not requested to insert the password the first opening of the program. It’s recommended to change the password to avoid undesired accesses to the program (to change the password, please refer to the Operation and Maintenance Terminal Software User’s manual). 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 10 91 080 0716F – Rel.06 - Click ‘Ok’ to start the software. The window ‘Communication settings’ is displayed: check that local ‘Connection mode’ is selected. If remote Connection mode is selected it is possible to change the Connection mode as follows: - select the ‘Edit and save’ button in the lower part of the panel to enable changes; - select local Connection mode; - press the ‘Edit and save’ button again to confirm (FIGURE 9). Edit and save button FIGURE 9 – ‘COMMUNICATION SETTINGS’ PANEL 9. SET THE REPEATER GAIN, FREQUENCY CENTER AND BANDWIDTH Select the menu entry ‘Read’ in the ‘Communications’ menu, or click the ‘ the equipment configuration and status. The software main window is displayed. By means of the software set the repeater gain as described below. Read’ button, to read NOTE How to modify parameters: - Click on the ‘edit and save’ button, in the lower part of the window, to enable changes to the repeater parameters. - Click again on the ‘edit and save’ button to save changes. - The menu entry ‘Write’, in the ‘Communications’ menu, makes it possible to apply changes to the repeater. A password is required: default password is blank. To change the password please refer to the software User’s manual. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 11 91 080 0716F – Rel.06 a) In the tree structure of the repeater system (Figure 9) select the repeater (double click on ‘Repeater’): on the right side of the window, the configuration and status panels of the repeater will be shown (Description, Spectrum, Parameters, Alarms, Communications, Advanced). b) In the description panel, the user should select (FIGURE 10) if the system is TDMA or CDMA. This selection allows to load the right values of RF power transmitted by the HPAs (only for 800MHz repeaters). FIGURE 10 – Selection TDMA / CDMA c) In the ‘Spectrum’ panel (FIGURE 11)set both ‘UL-attenuation’ and ‘DL-attenuation’ to 30 (dB) maximum attenuation, i.e. minimum gain. d) Connect the cable from the donor antenna to the BTS connector on the bottom of the repeater (ref. 52, FIGURE 3). e) Connect the MS connector on the bottom of the repeater (ref. 56, FIGURE 3) to a spectrum analyzer. f) In the Spectrum panel, set the Up-link frequency center and bandwidth. In the same panel set the repeater gain (UL-Up-link- attenuation, DL-Down-link- attenuation). PLEASE NOTE: should it be necessary to set an attenuation greater than 15dB it is strongly recommended to connect a fixed attenuator between donor antenna and the repeater BTS side port to avoid BTS desensitisation due to excessive radiated up-link noise. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 12 91 080 0716F – Rel.06 g) Check via the spectrum analyzer that the output signal level (MS side) is correct. When the output signal level is correct, disconnect the spectrum analyzer. FIGURE 11 – ‘SPECTRUM’ PANEL - EXAMPLE If the repeater is used in stand-alone configuration, connect the cable from the service antenna to the MS connector on the bottom of the repeater (ref. 56, FIGURE 3). If the repeater is the head station of an optical fiber system, refer to the OPTICAL FIBER COVERAGE SOLUTIONS technical handbook to install and set Master Unit and Remote Units. If the repeater is part of a cascade system, refer to the IN-LINE AMPLIFIERS technical handbook to install and set in-line amplifiers. During operation the equipment can be managed, both in LOCAL and in REMOTE mode, via the software. In REMOTE mode the equipment is managed via a modem link. On the repeater side the modem is installed within the equipment management module. In case of repeater equipped with GSM modem, if installing /removing the SIM card from the built-in modem is necessary, please refer to the for procedure 6b (HOW TO INSTALL/REMOVE THE SIM CARD FROM THE BUILT-IN MODEM). For details regarding the software, please refer to the software User’s manual. 4.3) CLOSING THE EQUIPMENT The repeater front door has to be closed carefully to guarantee protection of the equipment (i.e. to prevent dust and water getting inside the box). All the screws located on the equipment front door have to be appropriately tightened. We suggest you use an X tightening sequence 4.4) ROUTINE MAINTENANCE This equipment does not require any ORDINARY MAINTENANCE (or preventive maintenance) servicing. 800MHz-900MHz Off-Air Repeaters (OR Series) CHAPTER 4 Page 13 91 080 0716F – Rel.06 ABBREVIATIONS AND ACRONYMS AC ALC BDA BTS DC DCS EGSM EMC FET GSM GSM-R HPA IF IP3 LNA MMIC MS MTBF MU NF OMC OMT PC PEP PLL PSTN RAM RF RL RU SAW SIM SPV TTL UMTS UPS VCO Alternating Current Automatic Level Control Bi-Directional Amplifier Base Transceiver Station Direct Current Digital Cellular System Enhanced Global System for Mobile Communications Electro-Magnetic Compatibility Field-Effect Transistor Global System for Mobile Communications GSM - Railway High Power Amplifier Intermediate Frequency Third order Intercept Point Low Noise Amplifier Monolithic Microwave Integrated Circuit Mobile Station Mean Time Between Failures Master Unit Noise Figure Operation and Maintenance Center Operation and Maintenance Terminal Personal Computer Peak Envelope Power Phase-Locked Loop Public Switched Telephone Network Random Access Memory Radio Frequency Return Loss Remote Unit Surface Acoustic Wave Subscriber Identity Module Supervision Transistor, Transistor, Logic Universal Mobile Telecommunications System Uninterruptible Power Supply Voltage Controlled Oscillator ABBREVIATIONS AND ACRONYMS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creation Date--Text : 11/2/2006 13:31:28 Producer : GNU Ghostscript 7.06 Format : application/pdf Creator : Title : Creator Tool : PScript5.dll Version 5.2 Modify Date : 2007:11:14 13:50:55+01:00 Metadata Date : 2007:11:14 13:50:55+01:00 Document ID : uuid:372330fb-ffb9-413b-83c9-776ce79d65c6 Instance ID : uuid:60e1cf06-f350-4559-9074-98cd2461c756 Page Count : 51 Page Layout : SinglePage Create Date : 11/2/2006 13:31:28 Author :EXIF Metadata provided by EXIF.tools