Radio Thermostat of America USZW5202 Z-Wave USNAP module User Manual RTZW 02 IB 15Jan14 20140124
Radio Thermostat Company of America, Inc Z-Wave USNAP module RTZW 02 IB 15Jan14 20140124
QO8-USZW5202 User Manual REV 2
Product Name: Product Name: RTZW-02 Document Title: RTZW-02 user guide IB -ENG Document Type Code: IBIE Part Number: 1005-019 24jan14 vc add FCCID: QO8-USZW5202 info. 15jan14 vc initial release (refer to zwave_IB_r0.16_25may11.ai) NOTE: IB made from one A4 pge folded four times yet some other models of the CT-Series (like the CT-80) are only capable of working in your HVAC system with the C-wire present. Z-Wave USNAP Module User Guide ® ® The RTZW-02 USNAP module is designed to work with either constant present power in the thermostat (ie C-wire), or it can run only on batteries when no C-wire is present. Depending on which model CT-Thermostat you have, and how your CT-Thermostat is powered will determine which functionality the RTZW-02 module will have when added to a Z-Wave® network. The RTZW-02 USNAP module is a plug in module that adds Z-Wave® functionality to a CT-Series Thermostat [CT= Communicating Thermostat]. Getting Started A CT-Series Thermostat with an RTZW02 module is compatible with a broad range of Z-Wave® certified devices from other manufacturers and can be controlled wirelessly with Z-Wave® controllers supporting the Thermostat General V2 Device Class. Please consult the user manual and your controller supplier for more details. Examine your CT-Thermostat and identify an empty USNAP slot (refer to your CT-Thermostat instruction manual for details). 1) Power OFF the thermostat by removing batteries and disconnecting the C wire. 2) Insert the RTZW-02 module into the CT-Thermostat Radio Slot [ right side] with the label on the RTZW-02 facing the wall behind the thermostat. The RTZW-02 module should slide in and engage with no visible protrusion from the thermostat. 3) Power up the thermostat by re-installing the batteries and re-connecting the C wire. 4) Press the reset button on your CT (see thermostat documentation) and reset the CT by pressing the reset button for 1 second. The RTZW-02 provides two-way communication as part of a Z-Wave® network. When it receives commands from Controller device, it sends back confirmation that the command was received and implemented. Each module in a Z-Wave® network communicates with every other module, PG acting as a “repeater” and routing your commands to their destination by the most reliable pathway. When Z-Wave® devices (regardless of manufacturer) are installed throughout the house, signals are automatically routed around obstacles or dead spots, strengthening the network as more devices are added. During reset you should see the “radio tower” icon appear on your CT along with the slot number “2” indicating that the CT Thermostat is initializing the RTZW-02 USNAP module. When this finishes (about 15 seconds), your CT Thermostat will be ready to join and be controlled by a Z-Wave® network. The Basics Join or Un-Join Network The RTZW-02 USNAP module is designed to be inserted into the right side USNAP slot in any CT-Series Thermostat. (Follow the instructions that come with your CT-Series Thermostat and install it to your HVAC system before installing the RTZW-02 USNAP module.) 1) Set your primary controller to INCLUDE mode to add the thermostat as a node on your network (see your specific controller’s User Manual for detailed instructions). 2) Press/Touch the Mate Button. This will bring you to the network joining screen. Mate button: On touch screen units the MATE button is on the MENU screen. On basic LCD thermostat’s the mate button is under the top cover at the right side. Note: Some models of the CT-Series are capable of operating in battery only mode (i.e. without C-wire from HVAC system), PG 3) If you only have 1 USNAP module inserted in the thermostat you will see a r1 or r2 to indicate that the radio is in slot 1 or slot 2. If you have multiple radios you can select which radio you want to join the network by selecting an r1 or r2 from the top left hand corner of the screen. When you have selected a radio, the large r1 or r2 will appear in the center of the screen. PG front of page fold line 4) When the radio is selected and the large r1 or r2 is on the center of the screen, press the mate button, this will initiate the mating process. When a device has joined a network the icon LINK will appear under the radio tower. Similarly, when you are trying to leave a network, the icon LINK will disappear when the node has successfully left the network. Simple Mode/Normal Mode The CT-Thermostat offers two modes of operation, Normal Mode and Simple mode. Normal mode is intended for use as a stand alone programmable thermostat. In Normal mode the user can program the thermostat to change temperatures at various points throughout the day. Simple mode is intended for use with a larger control system - like an alarm system or home automation system. Simple mode is meant to run a single temperature constantly. This temperature can be set locally on the thermostat, or remotely using a Z-Wave® USNAP module. To enter simple mode: Press and hold the PROG button for 12 seconds. To leave simple mode, press and hold the PROG button for 12 Your controller will indicate the thermostat was successfully added to its network (see your specific controller’s User Manual for details.) For other controller specific tasks such as adding the thermostat to Scenes or Groups, or deleting the thermostat as a node, use the mate button to activate the Z-Wave® signal. Power Requirements Your thermostat ZWave module has been designed to work on either battery power or power from your furnace. If your HVAC system has a power wire (also known as a “C” or “COMMON” wire) and the thermostat is connected to the “C” wire, power will come from the furnace unless there is no power available and then power will come from the batteries. So, if you do not have a “C” wire, ask your HVAC technician to install one the next time you have your furnace upgraded or serviced. This will allow you to achieve optimal performance and convenience. Advanced Z-Wave® Information The RTZW-02 supports compliant mapping of the Z-Wave® BASIC_ COMMAND_CLASS to the CT thermostat “Energy Saving” and “Comfort Mode” as follows: Basic Set (Value = 0x00) = Set Energy Saving Mode Basic Set (Value = 0x01-0x63 & 0xFF) = Set Comfort Mode Remember to replace the three (3) AA batteries in your thermostat with new alkaline batteries whenever the low battery indicator comes on. If you leave your house for two weeks or more, it is essential for you to replace the batteries. If your thermostat is not powered by your HVAC system and has to rely entirely on batteries, PG 5 the HVAC system will stop working when the batteries die. Battery Power When your thermostat is running on battery power, the Z-Wave® radio will turn off to help conserve battery life. The RTZW-02 Z-Wave® radio module supports Z-Wave® beaming, which allows other devices in the network to wake up the RTZW-02 and accept commands, and then go back to sleep. Energy Savings applies a 4 F setback to the existing set point temperature to comply with EPA recommendations for energy savings. PG FCC and IC Statement FCC Regulatory Information: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct C-Wire Power When your thermostat is running on C-Wire power, the Z-Wave® radio will stay on and actively help in routing messages within the Z-Wave® network. the interference by one or more of the following measures: Operation a) reorient or relocate the receiving antenna, b) increase the separation between the equipment and receiver, c) connect the equipment into an outlet on a circuit different from that to which the receiver is connected. See your specific controller’s User Manual for detailed instructions on operating your thermostat. If your controller supports full thermostat device class functions then the following remote features are available: a) Up and Down Temperature Control b) Change between HEAT and COOL modes c) Read the current temperature d) Set/Read the indicator e) Set/Read the Fan mode f) Set/Read the clock (on certain CT models only) g) Set/Read the user display area (on certain CT models only) Consult the dealer or an experienced radio/TV technician for help. Contains transmitter module FCCID: QO8-USZW5202. IC Regulatory Information: This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. Cet appareillage numérique de la classe B répond a toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. WARNING: Changes or modifications to this receiver not expressly approved by RTCOA. could void the user’s authority to operate this equipment. NOTE: the SAVE ENERGY ffunction is disabled with Z-Wave operation. PG back of page PG 1005-019-000
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.351735, 2008/07/22-18:11:12 Format : application/pdf Title : RTZW-02 IB 15Jan14-20140124 Creator Tool : Adobe Illustrator CS4 Create Date : 2014:01:24 14:24:31+08:00 Modify Date : 2014:01:24 14:24:31+08:00 Metadata Date : 2014:01:24 14:24:31+08:00 Thumbnail Width : 148 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 16722 bytes, use -b option to extract) Document ID : xmp.did:5A4FF5F2B684E311A2F2DB5CC80A450B Instance ID : uuid:84fcd1e6-2f9f-42db-8d32-a63f18fe431f Rendition Class : proof:pdf Original Document ID : uuid:8B53FE49220AE01183E1BBB98E4B5384 Derived From Instance ID : uuid:62ae8fa4-6132-4f1c-a163-53965989a65b Derived From Document ID : xmp.did:584FF5F2B684E311A2F2DB5CC80A450B Derived From Original Document ID: uuid:8B53FE49220AE01183E1BBB98E4B5384 Derived From Rendition Class : proof:pdf History Action : saved, saved, saved, saved, saved History Instance ID : xmp.iid:4452BEAF6B86E011A291D6F7CCF01DE7, xmp.iid:92BE5F647D86E01187EAC7834E6B835D, xmp.iid:574FF5F2B684E311A2F2DB5CC80A450B, xmp.iid:584FF5F2B684E311A2F2DB5CC80A450B, xmp.iid:5A4FF5F2B684E311A2F2DB5CC80A450B History When : 2011:05:25 11:14:54+08:00, 2011:05:25 11:16:33+08:00, 2014:01:24 13:18:24+08:00, 2014:01:24 13:55:05+08:00, 2014:01:24 14:24:29+08:00 History Software Agent : Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4 History Changed : /, /, /, /, / Startup Profile : Print N Pages : 1 Has Visible Transparency : False Has Visible Overprint : True Max Page Size W : 609.600000 Max Page Size H : 609.600000 Max Page Size Unit : Millimeters Font Name : ArialMT, Arial-BoldMT, MyriadPro-Regular, Courier Font Family : Arial, Arial, Myriad Pro, Courier Font Face : Regular, Bold, Regular, Regular Font Type : Open Type, Open Type, Open Type, Bitmap Font Version : Version 3.00, Version 3.00, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671 Font Composite : False, False, False, False Font File Name : ARIAL.TTF, ARIALBD.TTF, MyriadPro-Regular.otf, Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Colorants Cyan : 80.000001 Swatch Groups Colorants Magenta : 5.000001 Swatch Groups Colorants Yellow : 10.000002 Swatch Groups Colorants Black : 0.000000 Swatch Groups Group Name : Grayscale Swatch Groups Group Type : 1 Swatch Groups Colorants Swatch Name: K=5 Swatch Groups Colorants Mode : GRAY Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Gray : 12 Producer : Adobe PDF library 9.00 Page Count : 1 Creator : Adobe Illustrator(R) 14.0 For : EE-Jojo Zhou, Bounding Box : -81 -329 840 1286 Container Version : 11 Creator Version : 14EXIF Metadata provided by EXIF.tools