Radwin 5XACULC-X Outdoor Subscriber Radio Unit User Manual

Radwin Ltd. Outdoor Subscriber Radio Unit

User Manual

            SU Pro, SU Air  Outdoor Subscriber Radio Unit    REFERENCE GUIDE
Regulatory Compliance    FCC/IC - Compliance  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and IC RSS standards. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This  equipment generates  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment  does  cause  harmful  interference  to  radio  or  television  reception,  which  can  be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  • Reorient or relocate the receiving antenna.   • Increase the separation between the equipment and receiver.   • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.   It is the responsibility of the installer to ensure that when using the outdoor antenna kits, only those antennas certified with the product are used. The use of  any  antenna  other than  those  certified  with  the  product  is  expressly forbidden by FCC 47 CFR Part 15.204 and IC RSS standards.   Il  est  de  la  responsabilité  de  l'installateur  de  s'assurer  que  lorsque  vous utilisez  les  kits  d'antennes  extérieures,  seules  les  antennes  certifiés  avec  le produit sont utilisés. L'utilisation d'une antenne autre que ceux qui sont  certifiés avec le produit est expressément interdite par la réglementation FCC partie 47 CFR  15.204 et IC normes RSS.      Outdoor  units  and  antennas  should  be  installed  ONLY  by  experienced installation professionals who are familiar with local building and safety codes and,  wherever  applicable,  are  licensed  by  the  appropriate  government regulatory  authorities.  Failure  to  do  so  may  void  the  product  warranty  and may expose the end user or the service provider to legal and financial Caution liabilities.  Resellers  or  distributors  of  this  equipment  are  not  liable  for  injury, damage or violation of regulations associated with the installation of outdoor units  or  antennas.  The  installer  should  configure  the  output  power  level  of antennas according to country regulations and antenna type.           SU Pro, SU Air Reference Guide  i Warning      Avertissement
   Les  unités  extérieures  et  les  antennes  doivent  être  installés  que  par  des professionnels  expérimentés  d'installation  qui  sont  familiers  avec  les  normes locales et les codes de sécurité et, si applicable, sont agréées par les autorités gouvernementales de réglementation compétents. Ne pas le faire peut annuler    la garantie du produit et peuvent exposer l'utilisateur final ou le fournisseur de services  d'obligations  juridiques  et  financiers. Revendeurs ou distributeurs de ces équipements ne sont pas responsables des blessures, des dommages ou violation des règlements liés  à  l'installation des unités extérieures ou des antennes. L'installateur doit configurer le niveau de puissance  de  sortie  des  antennes  conformément  aux  réglementations nationales et le type d'antenne.     This equipment should be installed and operated with a minimum distance of 110 cm between the radiator and your body.  Warning           Cet équipement doit être installé et utilisé à une distance minimale de 110 cm entre le radiateur et votre corps.       The module is granted to operate under FCC Rules in the 2.4 / 4.9 / 5.4 / 5.8 GHz bands.   Warning         This device complies with Part 15 of the FCC rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:  (1) This device may not cause harmful interference.   (2) This device  must accept  any interference received, including interference that may cause undesired operation.    Cet appareil  est  conforme la  norme  d'Industrie Canada exempts de  licence RSS  (s).  Son fonctionnement est soumis aux deux conditions suivantes:  1. Cet appareil ne peut pas causer d'interférences, et  2.  Cet  appareil  doit  accepter  toute  interférence,  y  compris  les  interférences  qui  peuvent causer un mauvais fonctionnement de l'appareil.   This Class B digital apparatus complies with Canadian ICES-003.  Cet appareil numrique de la classe B est conforme  la norme NMB-003 du Canada  SU Pro, SU Air Reference Guide ii  Prudence Avertissement
     Overview  The  ‘SU Pro,  SU  Air’  is an  Outdoor  Subscriber Radio  Unit  operating  in the  4.9  –  5.8  GHz frequency bands. It is a TDD OFDM radio supporting 10 MHz, 20 MHz, 40 MHz and 80 MHz channel bandwidths. The 2.4 GHz WiFi interface supports standard 802.11/n HT-20, HT-40 operation modes. The ‘SU Pro, SU Air’ supports cross polarized 2x2 MIMO antenna configuration for PtP and PtMP systems. The ‘SU Pro, SU Air’ supports 2 RF connectors for interfacing external cross polarized 2x2 MIMO antenna. The ‘SU Pro, SU Air’ also features an on-board WiFi 2.4 GHz interface  module  for  short  range  control  purposes.  The  ‘SU  Pro,  SU  Air’  is  powered  by  a 24Vdc PoE device. The ‘SU Pro, SU Air’ is certified with the FCC ID: Q3K-5XACULC-X and IC: 5100A-5XACULCX.     Condition of Use  The ‘SU Pro, SU Air’ is a proprietary radio device and can only be deployed and maintained by RADWIN professional installers or its authorized subcontractors    FCC rules and IC Regulation Restrictions  The ODU firmware is factory programmed to operate under the FCC rules and Industry Canada regulation restrictions. The firmware is locked and inaccessible by any third party. As a result of the above the user interface allows both the installer and the user to control the ODU only within the boundaries of the regional restrictions.    Antennas  The ‘SU Pro, SU Air’ is certified with a 17 dBi integrated flat crossed dual pole antenna type and  with  a  23  dBi  external  antenna,  both  covering  Point-to-Point  and  Point-to-Multipoint operation configurations.           SU Pro, SU Air Reference Guide                1
Certified Antenna Following are the antennas certified for use with the ‘SU Pro, SU Air’:  Antenna Type Manufacturer Model Number Frequency Range Antenna Max Gain (dBi) Dual Pole Integrated RADWIN Ltd. MP0179180 4940-4990 14      5150-5350 16 5470-5725 17 5725-5850 16 Dual Pole External RADWIN Ltd. RW-9614-5359 4940-4990 23 5150-5350 23 5470-5725 23 5725-5850 23 Omni RADWIN Ltd. On-Board 2400-2483.5 3   Maximum Output Power  5725 – 5850 MHz band - FCC/IC The maximum output power can  be  set as follows,  when  operating  in  the  5.8  GHz band, under FCC  47 CFR Part 15.407  New  Rules and IC  RSS-247  regulations. The  power values are  for  PtP  systems  and  PtMP  systems.  For  PtMP  systems  the  total  EIRP  is  limited  to  36 dBm. Therefore the output power of these systems will be reduced to comply with 36 dBm EIRP limit.  The highest conducted output power shall be limited to 29 dBm in all channel bandwidths  4940 – 4990 MHz band - FCC/IC The maximum output power can be set as follows, when operating in the 4.9 GHz band, under FCC 47 CFR Part 90Y Rule and IC RSS-111 regulations.   10 MHz: 21.0 dBm 20 MHz: 21.0 dBm   5150 – 5250 MHz band – FCC The maximum output power can be set as follows when transmitting in the 5.1 GHz band, under FCC 47 CFR Part 15.407 New Rules and regulations.  The total EIRP limit for PtP applications is 45 dBm. The total EIRP limit for PtMP applications is 36 dBm. The total EIRP limit for PtMP applications when transmitting at elevations above 30° relative to the horizon is 21 dBm.  10 MHz: 26.0 dBm    20 MHz: 28.0 dBm  40 MHz: 28.0 dBm 80 MHz: 29.0 dBm  SU Pro, SU Air Reference Guide        2
2400 – 2483.5 MHz band - FCC/IC The maximum output power can  be  set as follows,  when  operating  in  the  2.4  GHz band, under FCC 47 CFR Part 15.247 and IC RSS-247 regulations. The power values are for Wi-Fi systems for HT-20 and HT-40 Channel BW. The highest conducted output power shall be limited to 26 dBm in all channel bandwidths   5250 – 5350 MHz band – FCC/IC The maximum output power can be set as follows, when operating in the 5.3 GHz band. The total EIRP limit is 30 dBm.   10 MHz: 11.0 dBm    20 MHz: 14.0 dBm 40 MHz: 14.0 dBm 80 MHz: 14.0 dBm   5470 – 5725 MHz band – FCC/IC The maximum output power can be set as follows, when operating in the 5.4 GHz band. The total EIRP limit is 30 dBm.  10 MHz: 10.0 dBm    20 MHz: 13.0 dBm 40 MHz: 13.0 dBm 80 MHz: 13.0 dBm   Channel Bandwidths and Frequency Range                            SU Pro, SU Air Reference Guide 3  Channel BW [MHz] Center Freq. Range [MHz] 10 5730 - 5845 20 5735 - 5840 40 5745 - 5830 80 5765 - 5810 10 4945 - 4985 20 4950 - 4980 10 5160 - 5245 20 5165 - 5240 40 5170 - 5230 80 5190 - 5210 20 2412 - 2462 40 2422 - 2452 10 5255 - 5340 20 5260 - 5340 40 5270 - 5330 80 5290 - 5310 10 5480 - 5715 20 5485 - 5710 40 5495 - 5700 80 5520 - 5680
  Radio parameters accessed by end-user  The following parameters can be accessed by user: 1. Output Power 2. Frequency channel 3. Channel bandwidth                        SU Pro, SU Air Reference Guide        4

Navigation menu