Radwin AMWL1530 Point to Point Wireless TX User Manual WinLink 1000
Radwin Ltd. Point to Point Wireless TX WinLink 1000
Radwin >
Users Manual Revised
Installation and Operation Manual WinLink™ 1000 Point-to-Point Wireless Product Family Revision 4.11 WinLink 1000 Point-to-Point Wireless TDM/IP Revision 3.0 Installation and Operation Manual Notice This manual contains information that is proprietary to RADWin Ltd. ("RADWIN"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RADWIN Ltd. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the WinLink 1000 and any software components contained therein are proprietary products of RADWIN protected under international copyright law and shall be and remain solely with RADWIN. WinLink 1000 is a registered trademark of RADWIN. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the WinLink 1000. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the WinLink 1000, based on or derived in any way from the WinLink 1000. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the WinLink 1000 package and shall continue until terminated. RADWIN may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RADWIN, you agree to return to RADWIN the WinLink 1000 and all copies and portions thereof. For further information contact RADWIN at the address below or contact your local distributor. International Headquarters RADWIN Ltd. U.S. Headquarters RADWIN Inc. 32 Habarzel Street 900 Corporate Drive Tel Aviv 69710 Israel Mahwah, NJ 07430 USA Fax: 972-3-7662902 5777 Tel: 972-3-7662900 E-mail: support@radwin.com Tel: (201) 529-1100Fax: (201) 529E-mail: support-usa@radwin.com FCC-15 User Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance (RADWIN) could void the user’s authority to operate the equipment. It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), Warning only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. Quick Start Guide Installation of WinLink 1000 should be carried out only by a qualified technician. If you are familiar with WinLink 1000, use this guide to prepare the units for operation. 1. Installing WinLink 1000 Units ODU Package Contents: • ODU • Mast/Wall mounting kit • WinLink 1000 Management software installation CD • Mounting instructions • Spare RJ-45 connector • ODU to IDU cable at length ordered (optional) IDU-E Package Contents: • IDU-E • 110V/240V adaptor • IDU wall-mounting drilling template • Spare RJ-45 connector (Optional) IDU-C Package Contents: • IDU-C • For AC model, 110v/240 VAC with 3-prong connector cable • For DC model, -48 VDC with 3-pin terminal block connector (green) • IDU standard 1-U, 19” carrier rack • Spare RJ-45 connector Equipment Required: • RJ-45 crimp tool (If pre-assembled cable is not used) Installing WinLink 1000 Units Quick Start Guide WinLink 1000 Installation and Operation Manual • Drill (for wall mounting only) • IDU and ODU grounding cable • 13 mm or 1/2″ socket spanner • ODU to IDU cable if not ordered (Outdoor class, CAT-5e, 4 twisted pairs) • Cable ties • Laptop running Windows 2000 or Windows XP Before the installation 1. Install the WinLink 1000 software on the laptop. 2. Verify that all equipment and tools are available. Performing Installation Î To install the ODU: 1. At site A, route the ODU cable from the ODU location (on the roof) to the IDU location (inside the building). The maximum length is 100m. 2. Mount the ODU unit to the mast or wall, using the mounting kit. 3. Connect the RJ-45 connectors to both ends of the cable, use the pinout table and diagram below: Twisted Twisted Twisted Twisted IDU RJ-45 Wire Color Function ODU RJ-45 White/Green Ethernet (RxN) Green Ethernet (RxT) White/Orange Ethernet (TxT) Blue Power (+) White\Blue Power (+) Orange Ethernet (TxN) White/Brown Power (−) Brown Power (−) 4. Secure the ODU and ground cables to the mast or brackets using cable ties. 5. Repeat the procedure at site B. Installing WinLink 1000 Units WinLink 1000 Installation and Operation Manual Î Quick Start Guide To align the ODU: 1. Connect power to the IDU. Do not stand in front of a live outdoor unit. Warning The antenna used for this transmitter must be installed to provide a separation distance of at least 200 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 2. Align the site A ODU in the direction of the site B ODU. 3. Align the site B ODU in the direction of the site A ODU. 4. Alternating between each site, turn each ODU slowly listening to the buzzer beep sequence until optimal alignment is achieved. 5. Secure the site A and site B ODUs to the mast/wall. 6. Monitor the link quality for about 15 minutes to verify stability. 7. Connect the management station to one of the two IDUs in the link. 8. Start the WINLink Manager application. 9. Open the installation wizard and follow the installation steps. 10. After selection of the radio channel and the link rate, verify that the link quality bar in the WinLink manager is within the green range for TDM service and within the yellow range for Ethernet service. Note Achieve the best possible link quality values. In case of radio link loss, verify the ODU alignment, or change the radio channel in both sides of the link. When the radio link resumes continue the installation process. Connecting User Equipment Î To connect user equipment to the IDU: 1. Connect the user equipment (such as PBX) to the IDU RJ-45 port designated Trunk: On the rear panel of the IDU-E. On the front panel of the IDC-C, 2. Connect user hub/router or any other compatible device to the IDU RJ-45 port designated LAN: On the rear panel of the IDU-E. Installing WinLink 1000 Units Quick Start Guide WinLink 1000 Installation and Operation Manual On the front panel of the IDU-C. Note IDU-C has an integrated LAN switch that provide 2 port of 10/100BaseT. The Integrated LAN switch is not support spanning tree. The two LAN ports can be connected to 2 separated LAN segments but connection of both LAN ports to the same LAN segment will create a loop that fluid the network. Therefore, this configuration is prohibited. 2. Operating WinLink 1000 WinLink 1000 requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators and statistics data. Intervention is only required when WinLink 1000 must be configured to its operational requirements or diagnostic tests are performed: Normal Indications Upon turning on WinLink 1000, the PWR LED in the front panel lights to indicate that WinLink 1000 is on. The table below shows the correct status of the indicators after power-up. Indicator Color Status PWR Green On (only on IDU-E) Orange Blinks for short duration during startup ODU Green Blinking slowly shows normal operation AIR I/F Orange Blinks for short duration during startup Green Blinking slowly shows normal operation IDU SERVICE Green Green Operating WinLink 1000 Blinking slowly shows normal operation Blinking slowly shows normal operation OFF when SERVICE selected is Ethernet only WinLink 1000 Installation and Operation Manual Quick Start Guide Troubleshooting If the WinLink 1000 is not operational, determine the cause and solution from the table below. Led Status Remedy PWR Off For the IDU-E, check that AC adapter is connected IDU Orange Check that the IDU/ODU cable is properly wired ODU Red Check that the IDU/ODU cable is properly wired AIR I/F Orange to the IDU and the AC power outlet. and connected. and connected. Complete the installation procedure from the management software. Red Check the ODU Antenna alignment. Check that the radio configuration of both site A and site B units are the same (channel and SSID). SVC. Off Check the TDM service configuration in the NMS. Orange Check that the system is not in loopback mode. Check the site B IDU ports and cables and site B external equipment. Red Check the site A IDU ports, cables and external equipment. Operating WinLink 1000 Contents Chapter 1. Introduction 1.1 Overview .................................................................................................. 1-1 Application....................................................................................................... 1-1 Features ........................................................................................................... 1-2 1.2 Physical Description.................................................................................. 1-4 Chapter 2. Installation and Setup 2.1 WinLink 1000 System ............................................................................... 2-1 2.2 Site Requirements and Prerequisites ......................................................... 2-2 2.3 Package Contents ..................................................................................... 2-2 2.4 Installation and Setup ............................................................................... 2-3 Mounting the ODU ........................................................................................... 2-4 Connecting the ODU to the IDU ........................................................................ 2-5 Connecting the Power ...................................................................................... 2-6 Installing WinLink 1000 Management Software ................................................. 2-7 Aligning the WinLink 1000 ODUs...................................................................... 2-9 Installing the Link........................................................................................... 2-10 Connecting the User Equipment ..................................................................... 2-18 Chapter 3. Configuration 3.1 Performing Configuration of WinLink 1000 ............................................... 3-1 Configuring Service Parameters ...................................................................... 3-10 Editing the Configuration Parameters ............................................................. 3-13 Changing the Transmit Power......................................................................... 3-15 Defining the Management Addresses.............................................................. 3-15 3.2 Bridge Configuration .............................................................................. 3-17 Detailed description ....................................................................................... 3-17 ODU Bridge Mode........................................................................................... 3-18 IDU Aging time............................................................................................... 3-18 Chapter 4. Operation 4.1 Indicators ................................................................................................. 4-1 Panel Indicators................................................................................................ 4-1 Connector LED Indicators ................................................................................. 4-2 Installation and Operation Manual Table of Contents 4.2 Operating WinLink 1000 ........................................................................... 4-3 Turning On WinLink 1000................................................................................. 4-3 Normal Indications ........................................................................................... 4-4 Turning Off WinLink 1000 ................................................................................ 4-4 Changing the Password .................................................................................... 4-4 4.3 Managing WinLink 1000 ........................................................................... 4-5 Resetting WinLink 1000.................................................................................... 4-7 Saving WinLink 1000 Configuration in a File ..................................................... 4-7 Restoring a Configuration File .......................................................................... 4-8 Displaying the WinLink 1000 Inventory ............................................................. 4-8 Chapter 5. Diagnostics and Troubleshooting 5.1 Error Detection and Alarms....................................................................... 5-1 5.2 Collecting and Saving Statistics................................................................. 5-2 5.3 Running Diagnostic Loopbacks ................................................................. 5-3 Local External Loopback................................................................................... 5-4 Remote Internal Loopback ................................................................................ 5-5 Remote External Loopback ............................................................................... 5-5 Local Internal Loopback.................................................................................... 5-6 5.4 Troubleshooting ....................................................................................... 5-6 5.5 Frequently Asked Questions ..................................................................... 5-8 Air Interface ..................................................................................................... 5-8 Management .................................................................................................... 5-9 Services.......................................................................................................... 5-10 Antennas and Cables...................................................................................... 5-10 Competitve .................................................................................................... 5-10 5.6 Technical Support................................................................................... 5-11 Appendix A. Wiring Specifications Appendix B. Mast and Wall Installation Appendix C. Link Budget Calculator Appendix D. TDM Clock Configuration ii WinLink-1000 Installation and Operation Manual Table of Contents List of Figures 1-1. Typical Application .......................................................................................... 1-1 1-2. WinLink 1000 Units ......................................................................................... 1-4 2-1. Typical Installation Diagram ............................................................................ 2-4 2-2. IDUs connector panels..................................................................................... 2-6 2-3. Login Screen ................................................................................................... 2-8 2-4. Login vial Local Connection Screen .................................................................. 2-9 2-5. Main Menu ...................................................................................................... 2-9 2-6. Beeper Sequence for ODU Alignment ............................................................. 2-10 2-7. Link Installation Wizard ................................................................................. 2-11 2-8. Installation Wizard, System dialog box .......................................................... 2-12 2-9. Installation Wizard, Channel Select dialog box............................................... 2-13 2-10. Installation Wizard, Channel Select dialog box (Automatic Channel Select enabled) ........................................................................................................... 2-14 2-11. Installation Wizard, Channel Select dialog box (Supporting DFS, ETSI standard requirement) .................................................................................................... 2-15 2-12. Installation Wizard, Rates dialog box ........................................................... 2-16 2-13. Installation Wizard, Services dialog box ....................................................... 2-17 2-14. Installation Wizard, Finish Screen ................................................................ 2-18 3-1. WinLink Manager Main Menu ........................................................................... 3-2 3-2. Configuration Link Wizard ............................................................................... 3-3 3-3. Link Configuration, System dialog box ............................................................ 3-4 3-4. Link Configuration, Channel select dialog box................................................. 3-5 3-5. Link Configuration, Channel select dialog box with Automatic Channel select .3-6 3-6. Link Configuration, Channel select dialog box with DFS .................................. 3-7 3-7. Channel reselection confirmation dialog box ................................................... 3-8 3-8. Reselection process......................................................................................... 3-8 3-9. Reselection process "channel not active in list" ................................................ 3-9 3-10. Air Interface Rate select Dialog Box ............................................................... 3-9 3-11. Service Parameters Dialog Box, E1/T1 Interface ........................................... 3-11 3-12. Service Parameters Dialog Box, Ethernet only Interface ................................ 3-12 3-13. Configuration Link, Finish screen ................................................................ 3-13 3-14. Configuration Dialog Box ............................................................................ 3-14 3-15. Changing the Transmit Power...................................................................... 3-15 3-16. Configuration, Management ........................................................................ 3-16 3-17. Site configuration dialog box....................................................................... 3-17 Installation and Operation Manual iii Table of Contents 3-18. Hub mode selected ..................................................................................... 3-19 3-19. Hub mode, no IDU Aging............................................................................. 3-20 3-20. Bridge mode, no IDU Aging ......................................................................... 3-21 4-1. IDU Panels LEDs .............................................................................................. 4-1 4-2. Main Menu, Wireless Link is Active .................................................................. 4-5 4-3. WinLink 1000 Inventory................................................................................... 4-9 5-1. Preferences Dialog Box, Event Log Tab ............................................................ 5-3 5-2. Loopbacks Dialog Box ..................................................................................... 5-4 5-3. Local External Loopback .................................................................................. 5-5 5-4. Remote Internal Loopback ............................................................................... 5-5 5-5. Remote External Loopback .............................................................................. 5-6 5-6. Local Internal Loopback................................................................................... 5-6 iv WinLink-1000 Installation and Operation Manual Table of Contents List of Tables 4-1. IDU Panel LEDs ................................................................................................ 4-2 4-2. WAN/LAN LEDs................................................................................................ 4-2 4-3. TDM Traffic Indicators ..................................................................................... 4-2 4-4. WinLink 1000 Indicators at Startup .................................................................. 4-4 5-1. WinLink 1000 Alarms and Information Messages ............................................. 5-2 5-2. Troubleshooting with WinLink 1000 LEDs........................................................ 5-7 Table A-1. ODU-IDU Cable Connector Pinout ..........................................................A-1 Table A-2. E1/T1 Connector Pinout ........................................................................A-2 Table A-3. Fast Ethernet Connector Pinout..............................................................A-2 Table A-4. Terminal Block 3-pin -48VDC................................................................A-3 Table A-5. Alarm Connector (Dry-Contact) .............................................................A-3 Installation and Operation Manual Chapter 1 Introduction 1.1 Overview WinLink 1000 is a carrier-class, high capacity, Point-to-Point broadband wireless transmission system. WinLink 1000 combines legacy TDM and Ethernet services over 2.4GHz, 4.9GHz, and 5.xGHz license-exempt bands and is suitable for deployment in FCC, ETSI, or CSA regulated countries. The system provides up to 48 Mbps wireless link and supports ranges of up to 80 km (50 miles). Application Figure 1-1. Typical Application Features Wireless Link WinLink 1000 delivers up to 48 Mbps air rate for Ethernet and E1/T1 traffic. The system supports a variety of spectrum bands and can be configured to operate in any channel on the band with a carrier step resolution of 5 MHz. Overview 1-1 Chapter 1 Introduction WinLink 1000 Installation and Operation Manual WinLink 1000 operation complies with ETSI, CSA and the FCC 47CFR Part 15 and subpart C and E requirements. WinLink 1000 employs Time Division Duplex (TDD) transmission. This technology simplifies the installation and configuration procedure. There is no need to plan and to allocate separate channels for the uplink and downlink data streams. Operation over 2.4GHz, 4.9 GHz, and 5.x GHz bands is not affected by harsh weather conditions, such as fog, heavy rain etc. LAN Interface The WinLink 1000 LAN port provides 10/100BaseT interfaces with auto negotiation and transparent VLAN support. Traffic handling is provided by a MAC-level self-learning bridge. TDM Interface The WinLink 1000 TDM interface accepts E1 or T1 traffic, supporting the following: • Unframed operation (E1 and T1) • AMI and B8ZS zero suppression (T1). Management WinLink 1000 has full local and remote management capabilities. The user-friendly SNMP-based management tool provides full end-to-end configuration, event log and performance monitoring capabilities. Diagnostics and Performance Monitoring WinLink 1000 supports activating local and remote loopbacks on E1/T1 links. WinLink 1000 constantly monitors the data transmission process, evaluates received signal strength, and signal quality. It also monitors received traffic and frame rate (FPS) for local and remote units. Optional External Antenna WinLink 1000 supports configuration of an external antennas. In this configuration, the radio supplies an N-type connector that connects through a coax cable to the external antenna. 1-2 Overview WinLink 1000 Installation and Operation Manual Chapter 1 Introduction An external antenna can extend the range of the link, and in some cases, it might help to reduce environmental interferences. Various external antennas are available for the WinLink 1000 operating frequencies. For example, an optional flat panel 28 dBi external antenna increases the operation range of WinLink 1000 up to 80 km (50 miles). Overview 1-3 Chapter 1 Introduction WinLink 1000 Installation and Operation Manual 1.2 Physical Description Figure 1-2. WinLink 1000 Units IDU-E The IDU-E front panel includes five LEDs that display the status of E1/T1 and LAN, wireless link, self-test results, ODU-to-IDU link, and power status. For a detailed description of the front panel LEDs, see Chapter 4. The rear panel of the indoor unit (IDU) includes the power, WAN, LAN and E1/T1, and ODU connectors. The rear panel LEDs are described in Chapter 4, and the wiring specifications detailed in Appendix A. IDU-C The IDU-C front panel includes four LEDs that display the status of E1/T1and, wireless link, self-test results, and ODU-to-IDU link. For a detailed description of the front panel LEDs, see Chapter 4. 1-4 Physical Description WinLink 1000 Installation and Operation Manual Chapter 1 Introduction Technical Specifications Air-Interface Technology Frequency Band OFDM 2.400–2.483 GHz FCC/ETSI/IC 2.416–2.483 GHz (Israel) 4.940-4.990 GHz FCC 5.250–5.330 GHz FCC/IC 5.470–5.725 GHz FCC/ETSI 5.725–5.850 GHz FCC/IC Range Up to 80 km (50 miles) (*) Duplexing Method Time Division Duplex (TDD) Capacity Configurable up to 48 Mbps Modulation OFDM - BPSK, QPSK, 16QAM, 64QAM Channel setting Resolution 5 MHz (*) Transmitter Power 18 dBm max (*) ODU Installation Mast or wall mounting LAN Interface PHY IF E1 Interface T1 Interface Up to 2 x 10/100BaseT, auto-sensing (**) Framing/Coding IEEE 802.3/U Bridging Self-learning, up to 2K MAC addresses Line Impedance 100Ω VLAN Support Transparent Connector RJ-45 Data Rate 1, 2, 4 x E1 Line Interface HDB3 Connector RJ-45 Data Rate 1, 2, 4 x T1 Line Interface AMI, B8ZS Connector RJ-45 Unframed (Transparent) 2.048 MHz (**) Unframed (Transparent) 1.544 MHz (**) Physical Description 1-5 Chapter 1 Introduction Indicators Power WinLink 1000 Installation and Operation Manual PWR (green) Power status IDU (green) IDU status ODU (green/red) ODU-to-IDU link status AIR I/F (green/red) Air Interface status SERVICE (green/red) E1/T1 signal status Source IDU-E 100–240 VAC or -48VDC from rack Source IDU-C 100–240 VAC via cable & plug, or -24VDC or Power Consumption 10W max – IDU-E and ODU -48VDC from rack (**) 14W max – IDU-C and ODU Connector 2-pin for IDU-E IDU-C: DC ver: 3-pin terminal block AC ver: 3-prong plug Physical Outdoor Unit (ODU) with integrated antenna Height 305 mm / 12 in Width 305 mm / 12 in Depth 58 mm / 2.3 in Weight Indoor Unit Height 3.3 kg / 7.2 lb IDU-E 44 mm / 1.7 in (1U) IDU-C 43 mm / 1.7 in Width 237 mm / 9.3 in 297 mm / 11.5 in Depth 170 mm / 6.7 in 450 mm / 17.7 in Weight 0.58 kg / 1.4 lb 1.5 kg / 3.3 lb Environment Outdoor Unit (ODU) Enclosure All-weather case Temperature -35°C to 60°C/-31°F to 140°F Indoor Unit (IDU-E and IDU-C) 1-6 Physical Description WinLink 1000 Installation and Operation Manual Chapter 1 Introduction Temperature -5°C to 45°C/23°F to 113°F Humidity Up to 90%, non-condensing (*) Specification is different per product, for further details refer to the Link Budget Calculator (**) Specification is different per ordering option Antenna Characteristics Band (GHz) (***) 2.312- 2.400- 4.940- 5.250- 5.470- 5.725- 2.387 2.483 4.990 5.330 5.725 5.850 Integrated Antenna 1 ft Gain 16dBi 17dBi Beam width 20° 20° Polarization Linear Linear 22dBi 22dBi 22dBi 9° 9° 9° Linear Linear Linear 21 dBi 22 dBi 22 dBi 22 dBi 9° 9° 9° 9° Linear Linear Linear Linear N/A External antenna 1 ft Gain Beam width N/A N/A Polarization External Antenna 2 ft Gain 24dBi 24dBi 27 dBi 28dBi 28dBi 28dBi Beam width 8° 8° 8° 4.5° 4.5° 4.5° Polarization Linear Linear Linear Linear Linear Linear External Antenna 3 ft Gain 32.5 dBi Beam width N/A N/A N/A N/A 4.5° N/A Polarization Linear (***) IC related: 1. This device has been designed to operate with an antenna having a maximum gain of 28dBi. Antenna having a higher gain is strictly prohibited per regulations of industry Canada. The required antenna impedance is 50Ω. 2. Operation is subject to the following 2 conditions: a. This device may not cause interference. b. This device must accept any interference, including interference that may cause undesired operation of the device. Physical Description 1-7 Chapter 1 Introduction WinLink 1000 Installation and Operation Manual 3. Caution: High power radars are allocated at the follow frequencies ranges: 5250-5330MHz, 5650-5850MHz, these radars cause interference and/or damage to the LELAN device 1-8 Physical Description Chapter 2 Installation and Setup This chapter describes installation and setup procedures for WinLink 1000 system. After installing the unit, refer to Chapter 3 for configuration instructions and Chapter 4 for operation instructions. In case a problem is encountered, refer to Chapter 5 for test and diagnostic instructions. Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards Warning involved. Always observe standard safety precautions during installation, operation, and maintenance of this product. The operator of the spread spectrum intentional radiator or, if the equipment is professionally installed, the installer is responsible for Warning ensuring that the system is used exclusively for fixed, point-to-point operations . The instruction manual furnished with the intentional radiator shall contain language in the installation instructions informing the operator and the installer of this responsibility. Note WinLink 1000 has three types of products: • Auto channel selection is not supported–Previous or Future release. • Auto channel selection supported–User can enable/disable auto channel configuration. • DFS–Auto channel is mandatory. 2.1 WinLink 1000 System WinLink 1000 system comprises the following units: • Outdoor Unit (ODU): The ODU has 2 configurations: ODU with integrated antenna and ODU with N-Type connector for connection WinLink 1000 System 2-1 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual to an external antenna. Both ODU types have the same interface to the IDU. The ODU with integrated antenna has an enclosed aluminum frame with a front sealed plastic cover, containing an integrated transceiver with an antenna, RF module, modem and standard interfaces. ODU includes a power connector that receives -48 VDC and a RJ-45 for Ethernet traffic from the indoor unit (IDU). The ODU is attached to a mast using a special mounting kit, which is supplied with the unit. • Indoor Unit (IDU): There are two types of IDU cages. IDU-E that is a plastic box of ½ x 19 in. and IDU-C that is based on a metal 19in. box address the carrier-class applications. IDU is the interface unit between the ODU and the user. It converts 100–240 VAC to -48VDC, and feeds the ODU by it. The IDU does not store any configuration data. Therefore, there is no need for additional configuration of the WinLink 1000 system when replacing an IDU. 2.2 Site Requirements and Prerequisites For the IDU, allow at least 90 cm (36 in) of frontal clearance for operating and maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables. The ambient operating temperature should be –45°C to 60°C/-49°F to 140°F (ODU), or -5°C to 45°C/23°F to 113°F (IDU) at a relative humidity of up to 90%, non-condensing. Before starting the installation, use the Link Budget Calculator utility to calculate expected performance of the link. You can vary parameter inputs to the calculator to determine the optimum system configuration. The utility is described in Appendix C. 2.3 Package Contents The WinLink 1000 packages include the following items: ODU Package Containing: 2-2 • ODU • Mast/Wall mounting kit plus mounting instructions Package Contents WinLink 1000 Installation and Operation Manual • WinLink 1000 Manager installation CD • Spare RJ-45 Connector Chapter 2 Installation and Setup IDU-E Package Contents: • IDU-E • 110V/240V adaptor • IDU wall-mounting drilling template • Spare RJ-45 connector (Optional) IDU-C Package Contents: • IDU-C • For AC model, 110v/240 VAC with 3-prong connector cable • For DC model, –24VDC or -48 VDC with 3-pin terminal block connector (green) • IDU standard 1-U, 19” carrier rack • Spare RJ-45 connector External antenna (if ordered) ODU/IDU Cable at length ordered (optional) 2.4 Installation and Setup Physical installation of the WinLink 1000 system installation includes the following steps: 1. Installing ODU at both sites of the link. 2. Installing ODU cable and connecting ODU to IDU at both sites. 3. Connecting power. 4. Installing the management program on the network management station. 5. Aligning the ODUs. 6. Running the Installation wizard from the management program. 7. Connecting user equipment to the local and remote IDUs. Installation and Setup 2-3 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual Figure 2-1 illustrates a typical installation of WinLink 1000 with an external antenna. Figure 2-1. Typical Installation Diagram Mounting the ODU The ODU is the transmitting and receiving element of the WinLink 1000 system. The ODU can be mounted on a mast or a wall. In both installations, the supplied mounting kit is used to secure the ODU. Appendix B describes the mast/wall installation instructions. A WinLink 1000 link operates in pairs of two WinLink 1000 systems with the same configuration. Both systems must be installed, and the antennas of the outdoor units must be aligned for maximum throughput. 2-4 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup Prior to connecting cables to the ODU, the protective earth terminal (screw) of the ODU must be connected to an external protective ground Warning conductor or to a grounded mast. Only a qualified person using the proper safety equipment should climb the antenna mast. Only trained professional installers should be used when installing or dismantling ODUs and masts. Î To mount the ODU: 1. Verify that the ODU mounting brackets are properly grounded. 2. Attach the ODU unit to the mast. Refer to Appendix B for the ODU mounting instructions. 3. Connect the ground cable to the chassis point on the ODU. 4. Attach the ODU cable to the RJ-45 connector. Refer to Appendix A for the connector pinout. 5. Secure the cables to the mast or brackets using provided UV-rated cable ties. 6. Repeat the procedure at the remote site. Note Do not tightly secure the ODU to its mounting brackets, until the alignment process of the antenna is complete. When installing the ODU, it is important to check that there are no direct obstructions in front of the ODU or interference from man-made obstacles. Connecting the ODU to the IDU The ODU cable conducts all the user traffic between the IDU and the ODU. The ODU cable also provides -48 VDC supply to the ODU. The maximum length for one leg of the ODU cable is 100m (328 ft) in accordance with10/100BaseT standards. ODU cable is supplied pre-assembled with RJ-45 connectors, at the length specified when ordering. If the ODU cable was not ordered, use Cat. 5e shielded cable, the wiring specifications are given in Appendix A. 1. Route the cable from the ODU location into the building, leaving some spare. Secure the cable along its path. Installation and Setup 2-5 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual 2. Connect the ODU cable to the RJ-45 connector on the IDU panel designated WAN. Figure 2-2 illustrates a typical panel of the IDU-E and IDU-C. Error! Not a valid link. Figure 2-2. IDUs connector panels Note Other models may have a different configuration for these panels. Connecting the Power Before connecting any cable, the protective earth terminals of the AC/DC power must be connected to the protective ground conductor of the mains power cord. (Applies to both IDU models.) If you are using an extension cord (power cable) make sure it is grounded as well. Warning Any interruption of the protective (grounding) conductor (inside or outside the instrument) or disconnecting of the protective earth terminal can make this unit dangerous. Intentional interruption is prohibited. Power is supplied to WinLink 1000 via an external AC/DC converter, which receives power from 110–240 VAC source and converts it to -24VDC or -48 VDC. Î To connect the power IDU-E: 1. Connect the 2-pin plug of the AC/DC converter to the 2-pin DC power connector on the IDU-E rear panel. 2. Connect the AC/DC converter 3-prong plug to mains outlet. Î To connect the power for IDU-C: • For AC power model, connect the AC cable 3-prong plug to mains outlet. • For DC power model, connect to DC supply on the rack (male connector for the terminal block is included). 2-6 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup Installing WinLink 1000 Management Software WinLink 1000 management application is distributed on CD-ROM as an executable file. The application has the following PC requirements: • Memory: 128 MB RAM • Disk: 1 GB free hard disk space • Processor: Pentium 3 or higher • Network: 10/100BaseT NIC • Graphics: Card and Monitor that supports 1024×768 screen resolution with 16 bit color • Operating system: Windows 2000/XP • Microsoft Explorer 5.01 or later. Î To install the WinLink 1000 management program: 1. Insert the CD-ROM into your CD-ROM drive. 2. If the installation does not start automatically, run *.exe from the CD-ROM drive. 3. Follow the on screen instructions of the installation wizard to complete setup of the WinLink 1000 Management program in the desired location. Î To perform initial setup: 1. Power up the site A's IDU (see Connecting the Power on page 2-6 ). Wait about 1 minute. 2. Power up the site B IDU. 3. Connect the management station to the LAN. Any PC running the WinLink 1000 Management application can be used to configure WinLink 1000 units. Î To start WinLink 1000 manager: Note The ODU communicates with the management application using SNMPv1 protocol. The protocol defines three types of "passwords" called communities. These communities are Read-Only community for retrieving information from the ODU. A Read-Write community to configure and control the ODU, and a trap community used by the ODU Installation and Setup 2-7 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual to issue traps. Refer to Chapter 3, Community String on page for a complete description. 1. From the Start menu, point to Programs, point to WinLink 1000 Manager, and then click WinLink 1000 Manager. The password/IP request dialog appears. Error! Not a valid link. Figure 2-3. Login Screen 2. Select the suitable option for the IP Address field: Enter the IP address of the ODU — default value 10.0.0.120. Note The IP address is defined later during link configuration. (optional) If user is connected directly to the IDU LAN port, use the adjacent list arrow to select Local Connection. Error! Not a valid link. Figure 2-4. Login vial Local Connection Screen 3. Enter the password Default password – admin (see Chapter 4 for Changing the Password) The WinLink 1000 Manager Main menu is displayed (see Figure 2-5). Error! Not a valid link. Figure 2-5. Main Menu Aligning the WinLink 1000 ODUs Perform the WinLink 1000 ODU alignment using the Buzzers located inside the ODUs. Alignment of a WinLink 1000 link must be performed by two people simultaneously, at site A and at site B. Î To align the ODUs via ODU Buzzer: 1. Verify that power is connected to the IDUs at both sites. Do not stand in front of a live radio terminal. Warning 2. Align the site A ODU in the direction of the site B ODU. 3. Align the site B ODU in the direction of the site A ODU 2-8 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup 4. Alternating between each site, turn each ODU slowly while listening to the buzzer beep sequence for the Best Signal sound, until optimal alignment is achieved. 5. Secure the site A and site B ODUs to the mast/wall. 6. Monitor the link quality for about 15 minutes to verify stability. Buzzer Sequence =buzzer on Description =buzzer off Best Signal so far Signal quality increased No change in signal Signal quality decreased No air link Figure 2-6. Beeper Sequence for ODU Alignment Installing the Link Installation and definition of all parameters are applied to both sides of the link. Î To install the link: 1. Verify that the management station is properly connected to the same LAN as the IDU, and the WinLink 1000 Manager application is running. 2. In the toolbar, click the Link Installation button. The Installation wizard opens, (see Figure 2-7). Installation and Setup 2-9 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual Figure 2-7. Link Installation Wizard 3. Click next to proceed with the Installation procedure. The system dialog box opens (see Figure 2-8) 2-10 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup Figure 2-8. Installation Wizard, System dialog box 4. Enter a SSID (System ID) minimum of eight characters. The ID is initially factory set. Notes • Both sites of a link must always have the same number 5. Enter Link name for the link identification. 6. Enter a name for site 1. 7. Enter a name for site 2. 8. Click Next. The Channel Select dialog box appears (see Figure 2-9 for previous releases). Note For release 1.1.6 and above refer to Figure 2-10, page 2-13. For 5.4GHz DFS according to ETSI standard, refer to Figure 2-11 on page 2-14. Installation and Setup 2-11 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual Figure 2-9. Installation Wizard, Channel Select dialog box 9. Select the required operating channel. The pull down list shows the frequencies available. The Manual option allows you a User defined channel, within the system frequency band. Selecting a new channel causes the system quality to change. The quality bar shows the adjustment until the system finds the best quality link. Note 2-12 The installation of products that support automatic channel selection is performed in a user defined channel, called the installation channel. After selecting the channel, the list of channels for automatic channel selection can be modified. Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup Figure 2-10. Installation Wizard, Channel Select dialog box (Automatic Channel Select enabled) Note This feature is for the 5.4GHz ETSI version product only. DFS/TPC–Dynamic Frequency Select/Transmit Power control: according to ETSI standard for the unlicensed band that eliminates interruption of the wireless data equipment to the radar service. Installation and Setup 2-13 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual Figure 2-11. Installation Wizard, Channel Select dialog box (Supporting DFS, ETSI standard requirement) 10. Click Next. The Rate Select dialog box appears (see Figure 2-12) Table 1-1 lists throughput rates and capacities. 2-14 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup Figure 2-12. Installation Wizard, Rates dialog box 11. Select a suitable air interface rate according to the services required. 12. Click Evaluate. 13. A question box pops up, asking if you want to re-evaluate the link. Click Yes to change the rate No to keep the existing rate. Selecting a new rate causes the system quality to change. The quality bar shows the adjustment until the system finds the best quality link. 14. Click Next. The Service Parameters dialog box appears (see Figure 2-13). Error! Not a valid link. Figure 2-13. Installation Wizard, Services dialog box 15. In the Service dialog box, select one of the following: Installation and Setup 2-15 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual E1/T1 – Select the E1/T1 field, if you intend to transmit E1/T1 data and Ethernet data. The Ethernet BW field shows the remaining bandwidth in Mbps available for Ethernet. The available bandwidth depends on the number of E1/T1 ports selected. Select the Ethernet field, if you intend to transmit Ethernet data only 16. Click Next. The Finish screen appears (see Figure 2-14). The Finish screen shows a summary of the link configuration, the alignment is complete. Figure 2-14. Installation Wizard, Finish Screen 17. Click Finish to complete the installation wizard. 2-16 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup When the wireless link is established between the site A and site B units, the Link Status indication bar of the Main menu is within the green area. 18. Verify that the radio signal strength (RSS) in the Main menu is according to expected results. Connecting the User Equipment The IDU-E is a standalone desktop, wall-mounted unit. This unit has both front and rear panel connections. The optional IDU-C is a standalone rack mounted unit. This unit has only front panel connections. Figure 2-2 illustrates the typical panels of the IDUs. Î To connect user equipment to the IDU: 1. Connect user E1/T1 traffic to the appropriate IDU panel RJ-45 port designated Trunk. Refer to Appendix A for the connector pinout. 2. Connect user hub/router or any other compatible device to the appropriate IDU panel RJ-45 port designated LAN. Refer to Appendix A for the connector pinout. Note IDU-C has an integrated LAN switch that provides 2 ports of 10/100BaseT. The integrated LAN switch does not support spanning tree. The two LAN ports can be connected to two separate LAN segments, but connection of both LAN ports to the same LAN segment will create a loop that floods the network. Therefore, this configuration is prohibited. Installation and Setup 2-17 Chapter 2 Installation and Setup WinLink 1000 Installation and Operation Manual Figure 2-14. Installation Wizard, Finish Screen 17. Click Finish to complete the installation wizard. When the wireless link is established between the site A and site B units, the Link Status indication bar of the Main menu is within the green area. 18. Verify that the radio signal strength (RSS) in the Main menu is according to expected results. Connecting the User Equipment The IDU-E is a standalone desktop, wall-mounted unit. This unit has both front and rear panel connections. The optional IDU-C is a standalone rack mounted unit. This unit has only front panel connections. Figure 2-2 illustrates the typical panels of the IDUs. 2-18 Installation and Setup WinLink 1000 Installation and Operation Manual Chapter 2 Installation and Setup Î To connect user equipment to the IDU: 1. Connect user E1/T1 traffic to the appropriate IDU panel RJ-45 port designated Trunk. Refer to Appendix A for the connector pinout. 2. Connect user hub/router or any other compatible device to the appropriate IDU panel RJ-45 port designated LAN. Refer to Appendix A for the connector pinout. Note IDU-C has an integrated LAN switch that provides 2 ports of 10/100BaseT. The integrated LAN switch does not support spanning tree. The two LAN ports can be connected to two separate LAN segments, but connection of both LAN ports to the same LAN segment will create a loop that floods the network. Therefore, this configuration is prohibited. Note Use a straight cable for router connection. Installation and Setup 2-19 Chapter 3 Configuration This chapter describes configuration procedures that are performed after the link has been installed, synchronized, and the link configuration has been performed by wizard. Note WinLink 1000 has three types of products: • Auto channel selection is not supported–Previous or Future release. • Auto channel selection supported–User can enable/disable auto channel configuration. • DFS–Auto channel is mandatory. 3.1 Performing Configuration of WinLink 1000 After installing the link, the system configuration can be altered. Performing Configuration of WinLink 1000 3-1 Chapter 3 Configuration Note WinLink 1000 Installation and Operation Manual Installation and definition of all parameters are applied to both sides of the link. Figure 3-1. WinLink Manager Main Menu Î To change general parameters: 1. In the Main menu, click the Link Configuration button. 2. The Configuration Wizard opens. The wizard is used to make configuration changes. 3-2 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Figure 3-2. Configuration Link Wizard 3. Click Next. 4. The Link Configuration dialog box appears (see Figure 3-3). Performing Configuration of WinLink 1000 3-3 Chapter 3 Configuration WinLink 1000 Installation and Operation Manual Figure 3-3. Link Configuration, System dialog box 5. In the System dialog box, enter the new data to for the link. All fields with a white background can be edited. 6. Click Next. The Frequency dialog box appears (see Figure 3-4). For releases 1.1.6 and above, refer to Figure 3-6 on page 3-6. For 5.4GHz DFS according to ETSI standard, refer to Figure 3-6 on page 3-7. 7. Select the required operating channel frequency. 3-4 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Figure 3-4. Link Configuration, Channel select dialog box Selecting the Manual option provides the capability to configure the channel in 5 MHz steps in the specified band of the product. Note Some of the products support the Automatic channel selection. The mode is activated in normal operation mode. During installation the user must select the channel manually in order to optimize the antenna alignment. Enabling automatic channel selection is perform be clicking on the Automatic channel selection check box. After selecting this mode, the available channel list is enabled, and the user can select which channels are used for the automatic selection (at least two channels must be selected). The reselect channel button is used to change to a new channel from the available channels list. Performing Configuration of WinLink 1000 3-5 Chapter 3 Configuration Note WinLink 1000 Installation and Operation Manual By reselecting channel, the radio starts scanning all the channels from the available channels list and looks for radio activity in each of the channels. It tries to select the optimal channels. If another channels is desired the operating channel must be removed from the available channel list. Some product configurations support the DFS/TPC ETSI Standard. In this standard, The Radio is detects Radars and selecting only channels were no active Radars. According to the standard, a channel with active Radar is prohibited for 30 minutes. Also before any transmission the device probe the channel for Radar for a period of 60 seconds before it can start transmission. Figure 3-5. Link Configuration, Channel select dialog box with Automatic Channel select 3-6 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Note Chapter 3 Configuration This feature is for the 5.4GHz ETSI version product only. DFS/TPC – Dynamic Frequency Select / Transmit Power control – ETSI standard for the unlicensed band that eliminates interruption of the wireless data equipment to the radar service. The sign on the configuration Wizard and Status bar indicates that the radar detection is on. Figure 3-6. Link Configuration, Channel select dialog box with DFS Note Automatic channel selection cannot be unchecked, due to ETSI standard requirements. A Channel reselection process interrupts the service for the period of scanning and re-synchronization of the link. In most of the product this process takes few seconds. In products that support DFS/TPC this process might take few minute (each channel must be monitored for a 60 seconds before any transmission can start. Performing Configuration of WinLink 1000 3-7 Chapter 3 Configuration WinLink 1000 Installation and Operation Manual Figure 3-7. Channel reselection confirmation dialog box Figure 3-8. Reselection process Note 3-8 Reselection process can take up to few minutes. A bar with activity displays the progress of the reselection process. Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Figure 3-9. Reselection process "channel not active in list" 8. Click Next. The Rate Select dialog box appears (see Figure 3-10) Table 1-1 lists throughput rates and capacities. Figure 3-10. Air Interface Rate select Dialog Box 9. Select a suitable air interface rate according to the services required. 10. Click Evaluate. Performing Configuration of WinLink 1000 3-9 Chapter 3 Configuration Note WinLink 1000 Installation and Operation Manual The Evaluate button becomes enabled when a new rate has been selected. 11. A question box pops up, asking if you want to re-evaluate the link. Click Yes to change the rate or No to keep the existing rate. Selecting a new air-interface rate causes the system to change its air-interface rate and commence evaluation of the link performance at the new air-interface rate. This process of evaluation takes a few seconds. 12. Click Next. The Service Parameters dialog box appears. Configuring Service Parameters In the Service Parameters dialog box configure E1/T1 (x1 or x2) and Ethernet parameters. Î To configure E1/T1 and Ethernet: 1. In the Service dialog box, select one of the following: E1/T1 – Select the E1/T1 field, if you intend to transmit E1/T1 data and Ethernet data. The Ethernet BW field shows the remaining bandwidth in Mbps available for Ethernet. The available bandwidth depends on the number of E1/T1 ports selected. Select the Ethernet field, if you intend to transmit Ethernet data only 3-10 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Figure 3-11. Service Parameters Dialog Box, E1/T1 Interface Performing Configuration of WinLink 1000 3-11 Chapter 3 Configuration WinLink 1000 Installation and Operation Manual Figure 3-12. Service Parameters Dialog Box, Ethernet only Interface 2. Click Next. The Finish screen appears (see Figure 3-13). The Finish screen shows a summary of the link configuration. 3-12 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Figure 3-13. Configuration Link, Finish screen 3. Click Finish to complete the configuration wizard. The Main screen is displayed. Editing the Configuration Parameters The configuration parameters can be edited for each site individually without running a wizard. Î To edit the Configuration Parameters: 1. Click configuration from the main menu. 2. Select which site to configure. The configuration dialog box opens. (See Figure 3-14) Performing Configuration of WinLink 1000 3-13 Chapter 3 Configuration WinLink 1000 Installation and Operation Manual Figure 3-14. Configuration Dialog Box 3. In the Configuration dialog box, edit the data to for the link: System Tab – The contact person and location details can be edited. Air Interface Tab – Used for changing the transmit power Inventory Tab – This screen is read only and cannot be edited Management Tab – To configure the IP address, Subnet Mask, Default Gateway, and the Trap Destination. Backup button – Save a “backup” ini file with current configuration. Restore button – Load the “backup” ini created by the Backup button. Install Mode – return to Install Mode for the entire link. The Buzzer can be muted by selecting the Mute check box before click the Install Mode button. 4. Click Apply to save the changes. 3-14 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Changing the Transmit Power Each ODU can be configured to have a different transmit power level. Î To change the Transmit Power: 1. Click configuration from the main menu. 2. Select which site to configure. The configuration dialog box opens. 3. Click the Air Interface Tab. (See Figure 3-15) 4. Select the required Transmit Power Level (See Figure 3-15, below). Figure 3-15. Changing the Transmit Power Defining the Management Addresses Each site must be configured separately, first site A then site B. Î To define the Management Addresses: 1. Click configuration from the main menu. 2. Select which site to configure. The configuration dialog box opens. Performing Configuration of WinLink 1000 3-15 Chapter 3 Configuration WinLink 1000 Installation and Operation Manual 3. Click the Management Tab (see Figure 3-16). 4. Enter the IP address of the ODU in the IP address field. Note If performing configuration from the WinLink manager, the IP address is entered in the login screen (Figure 2-3) 5. Enter the Subnet Mask. 6. Enter the Default Gateway. 7. Enter the Trap Destination. This is the IP address of the PC running the management application. The event log will be stored at this address. Figure 3-16. Configuration, Management 3-16 Performing Configuration of WinLink 1000 WinLink 1000 Installation and Operation Manual Notes Chapter 3 Configuration The Install mode button opens the Main Window for installation mode for reinstalling the link. The Backup and Restore buttons are for saving and restoring the configuration files. 3.2 Bridge Configuration Bridge configuration is required in various network topologies, such as protection (1+1) and ring application. Detailed description The bridge configuration parameters are available from the Advanced tab of the site configuration dialog box (Figure 3-17 ). There are two parameters: • ODU bridge mode • IDU Aging time Figure 3-17. Site configuration dialog box Bridge Configuration 3-17 Chapter 3 Configuration WinLink 1000 Installation and Operation Manual ODU Bridge Mode This parameter controls the ODU mode with two optional values, • Bridge Mode (default) (Figure 3-17 ). In "bridge" mode the ODU performs both learning and aging, the aging time of the ODU if fixed. • Hub Mode - in "hub" mode the ODU transparently forward the all the packets over the wireless link. Note Changing these parameters requires system reset. IDU Aging time This parameter controls the IDU (E and C) aging time. The IDU has 2K MAC address learning table. The aging time parameter controls the time each MAC address is dropped from the table. Default value is 300 (sec). Note Change to these parameters is effective immediately. Note Each side of the link can be configured separately. The following list detail common configurations, both sides are configured with the same values. • Standard (Default) Configuration for Ethernet Applications IDU-E or IDU-C aging is set to 300 sec (ODU is set to Bridge mode, Figure-1). • Fast aging mode (for rapid network topology changes) IDU-E or IDU-C aging is set to 1 seconds, ODU is set to Hub mode (Figure 3-18). 3-18 Bridge Configuration WinLink 1000 Installation and Operation Manual Chapter 3 Configuration Figure 3-18. Hub mode selected Bridge Configuration 3-19 Chapter 4 Operation This chapter provides the following information for WinLink 1000: • WinLink 1000 front panel indicators on IDU-E and rear panel on IDU-C. • Operating procedures (turn-on, front panel on IDU-E and rear panel on IDU-C indications, performance monitoring and turn-off) 4.1 Indicators Panel Indicators The panels of WinLink 1000 include a series of LED indicators that show the operating status of the unit. Figure 4-1, below shows the front panel of the WinLink 1000 unit, Table 4-1 describes the indicators. Figure 4-1. IDU Panels LEDs Indicators 4-1 Chapter 4 Operation WinLink 1000 Installation and Operation Manual Table 4-1. IDU Panel LEDs Name Color Function PWR Green ON – A power supply is ON IDU-E only IDU Green ON– IDU operational Orange ON– During power-up only Red ON – Failure Green ON – ODU-to-IDU communication link is operating Red ON – ODU-to-IDU communication link is disrupted Green ON – Wireless link is synchronized Orange ON – During installation only Red ON – Wireless link lost synchronization Green ON – E1 or T1 line is synchronized Orange ON – Alarm detected at the remote interface Red ON – Alarm detected at the local interface ODU AIR I/F SERVICE ON – Local or Remote loopback Connector LED Indicators The IDU connectors of WinLink 1000 have LED indicators that show the operating status. Table 4-4 describes the indicators. Table 4-2. WAN/LAN LEDs Name Color Function Location LINK Green ON – Good Ethernet link integrity WAN/LAN ACT Yellow Blinks according to the Ethernet traffic connectors WAN/LAN connectors Table 4-3. TDM Traffic Indicators 4-2 Function Green LED Red LED OK On Off AIS Off On LOS Off On Loopback On Blinking Indicators WinLink 1000 Installation and Operation Manual Chapter 4 Operation 4.2 Operating WinLink 1000 Turning On WinLink 1000 Î To turn on WinLink 1000: • Connect the AC/DC converter to the IDU-E power connector and to the mains; or -48VDC from rack or AC 110-240VAC. The PWR indicator lights up and remains lit as long as the IDU is receiving power. WinLink 1000 requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators and statistics data. Intervention is only required when WinLink 1000 must be configured to its operational requirements, or diagnostic tests are performed. Operating WinLink 1000 4-3 Chapter 4 Operation WinLink 1000 Installation and Operation Manual Normal Indications Upon turning on WinLink 1000, the PWR LED in the IDU front panel lights to indicate that WinLink 1000 is on. Table 4-4 shows the correct status of the indicators at power-up. Table 4-4. WinLink 1000 Indicators at Startup Indicator Color Status PWR Green ON IDU-E only IDU Orange ON for short duration during startup Green ON during normal operation ODU Green ON-shows normal operation AIR I/F Orange ON for short duration during startup Green ON shows normal operation SERVICE Green ON shows normal operation OFF when Service is configured for Ethernet only If the above LED indications do not appear following initial power turnon, refer to Chapter 5 for the diagnostic test instructions. Note During normal operation, the PWR led stays ON; all other LEDs blink at approximately a four second cycle. Turning Off WinLink 1000 Î To turn off WinLink 1000: • (IDU-E) Remove the AC/DC converter power cord from the mains. (IDU-C) Remove 48VDC from rack or AC 110-240VAC (IDU-C). Changing the Password Î To change the password 1. From the Tools menu, select Change Password 2. The Change Password dialog box appears. 3. Enter current password, and new password. 4. Click Ok to confirm. 4-4 Operating WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 4 Operation 4.3 Managing WinLink 1000 Before starting a management session, make sure that a communication link between local and remote units exists, the Link Status indication bar in the middle of the Main menu must be green; the Radio Link - Sync message appears in the event log (see Figure 42). Figure 4-2. Main Menu, Wireless Link is Active The WinLink Manager Main menu consists of the following elements: • Toolbar – includes buttons serving for: Changing configuration parameters of operating wireless link, assigning text files for storing alarms, statistics and configuration data (Link Configuration button) Performing preliminary configuration of the system (Link Installation button). This button is disabled once a link is defined. Clearing error counters (Clear Counters button) Logging off WinLink Manager (Log Off button) Managing WinLink 1000 4-5 Chapter 4 Operation WinLink 1000 Installation and Operation Manual • Exiting WinLink Manager (Exit button) Menu bar File Menu – Log off, and exit Configuration – use for link configuration, individual site configuration or link installation • Tools – set preferences, event log handling, change password Maintenance – Loopbacks, system reset. Link details pane – summarizes information on the radio frequency, air interface rate, type of TDM service, and IP details of the local and remote WinLink 1000 units. • Monitor pane – displays the link quality between local and remote devices and the following statistics: • Local/remote received traffic rate (in kbps) Local/remote received frames rate (in fps) Radio link status E1 or T1 link status Radio signal strength (RSS) in dBm Block error rate Event log – stores both alarms and traps: Alarms and traps also generated by NMS (e.g. counter clear, device unreachable, etc.) • Traps: Monitoring for radar activity on channelGHz. – Apply to DFS/TPC products only. T trap is issued when the ODU starts the looking for radar. Radar activity was detected in , on channel GHz. Apply to DFS/TPC products only. The ODU detected radar. The channel is prohibit for 30 minutes. Transmitting on channel GHz. – The ODU started transmission on a channel. Channel scanning in progress. The ODU start searching the remote ODU in all channels. 4-6 Configuration problem detected. Link installation required. Managing WinLink 1000 WinLink 1000 Installation and Operation Manual Î Chapter 4 Operation TDM Service - Alarm. (added in 1.1.3) TDM Service - Normal. (added in 1.1.3) To change link configuration parameters: 1. In the Main menu, click Configure Link. The Configure Link wizard appears. See Chapter 3 for configuration details. 2. Click Next. 3. Continue through the configuration wizard and define the Link name and ID, Channel, Rate and Services. 4. Once you finish changing configuration parameters, click Finish. The system takes a few seconds to activate the link with the new configuration. Resetting WinLink 1000 Note Î In order to maintain the communication link, always reset the remote WinLink 1000 first. To reset WinLink 1000: 1. Click on maintenance, select the remote WinLink 1000 to reset. 2. Click on maintenance, select the local WinLink 1000 to reset. Saving WinLink 1000 Configuration in a File WinLink 1000 management software allows you to save configuration parameters of the local and remote units on the management station as an INI file. Each site is saved in a separate INI file. Î To save configuration in a file: 1. From the Configuration menu, select the site to backup. The Configuration dialog box opens (see Figure 3-9). 2. Click Backup. 3. In the Save As dialog box, indicate in which folder and under what name configuration file is to be saved, and click Save. Managing WinLink 1000 4-7 Chapter 4 Operation WinLink 1000 Installation and Operation Manual Restoring a Configuration File Configuration files (*.ini) can be uploaded from the management station, if the WinLink 1000 database becomes corrupted. This can also be used to distribute verified configuration files to all other units that use the similar configuration. Î To restore a configuration file to WinLink 1000: 1. From the Configuration menu, select the site to reconfigure. The Configuration dialog box opens (see Figure 3-9). 2. Click Restore. 3. From the Open dialog, select *.ini file to upload and click OK. Displaying the WinLink 1000 Inventory The WinLink 1000 inventory includes information on the hardware, firmware and software versions of the local and remote units. Î To display inventory: • In the Configuration dialog box (see Figure 3-9), click the Inventory tab. The local and remote inventory information is displayed (see Figure 4-3). 4-8 Managing WinLink 1000 WinLink 1000 Installation and Operation Manual Chapter 4 Operation Figure 4-3. WinLink 1000 Inventory Managing WinLink 1000 4-9 Chapter 5 Diagnostics and Troubleshooting This chapter describes the WinLink 1000 diagnostic functions, which include: • Status indications, alarms, power-up self-test • Statistics collection • Diagnostic tests (local and remote loopbacks on E1 or T1 link). 5.1 Error Detection and Alarms WinLink 1000 detects fault conditions of the radio and user links and initiates alarms to alert the user. Note To store the event log, first define the IP address, subnet mask, default gateway and trap address of the management PC, see Chapter 3 for details. Alarms (traps) are displayed in the Event Log in the lower panel of the Main Menu screen. The alarm log is saved as a TXT file. The event log includes the following fields: • Sequential number (ID) • Date and time stamp • Message • Trap source • IP address of the ODU that initiated alarm. Error Detection and Alarms 5-1 Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual Table 5-1. WinLink 1000 Alarms and Information Messages Message Description Radio Link – Sync Radio link is synchronized Radio Link – Out Of Sync Radio link lost synchronization Link Has Been Reset ODU was reset due to internal problem TDM Interface – Normal TDM interface is operating properly TDM Interface – LOS Loss of Synchronization is reported by TDM interface TDM Interface – LOS Loss of Signal is reported by TDM interface TDM Interface – AIS Alarm Indication Signal is reported by TDM interface TDM Interface – Loopback A loopback is active on TDM interface Link Resetting Wireless link reset from the management station. This alarm is caused by automatic reset after link configuration. Local ODU Resetting The local ODU reset from the management station. Monitor was stopped since no No ODU-to-IDU traffic was detected during the last 20 connection to the link minutes. 5.2 Collecting and Saving Statistics WinLink 1000 constantly monitors traffic over the radio link and collects the following statistics data: • Site 1/Site 2 received traffic rate (in Kbps) • Site 1/Site 2 received frames rate (in Fps) • Radio signal strength (in dBm) • Error (Blocks). The statistics (monitor) log and event log can be saved as TXT files. New alarms are automatically added to the text file, as they enter the event log. Î To save event log or monitor log: 1. From the Tools menu, choose Preferences. The Preferences dialog box appears (see Figure 5-1). 2. From the Preferences dialog box, select the file to save. 5-2 Collecting and Saving Statistics WinLink 1000 Installation and Operation Manual Chapter 5 Diagnostics and Troubleshooting 3. Click the check box to open the file for saving. 4. Click the button and in the Select File dialog box indicate in which folder and under what name the alarm log file is to be saved, and click OK. 5. Set the time interval for adding data to the file. Figure 5-1. Preferences Dialog Box, Event Log Tab 5.3 Running Diagnostic Loopbacks WinLink 1000 supports activation of the internal and external loopbacks on the local and remote units. Î To activate a loopback: 1. From the Maintenance menu, choose Set Loopbacks. The Loopbacks dialog box appears (see Figure 5-2). 2. From the Local or Remote drop-down box, select a loopback that you intend to run, and click OK. A confirmation message appears. PM Running Diagnostic Loopbacks 5-3 Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual 3. Click OK to activate a loopback. WinLink 1000 activates selected loopback. A loopback status arrow in the Main menu turns green to indicate an active loopback. Î To deactivate a loopback: • From the From the Local or Remote drop-down box of the Loopbacks dialog box, select None and click OK. A loopback is deactivated and the corresponding status arrow in the Main menu becomes dimmed. Figure 5-2. Loopbacks Dialog Box Local External Loopback Local WinLink 1000 can be set to an external loopback to test the local E1/T1 port and its connection to the local side user equipment. In this mode, data coming from the local user equipment is looped back to it (see Figure 5-3). This loopback is initiated from a management station connected to the local unit. 5-4 Running Diagnostic Loopbacks WinLink 1000 Installation and Operation Manual Chapter 5 Diagnostics and Troubleshooting E1/T1 Interface Testing Equipment Local ODU Management Station Figure 5-3. Local External Loopback Remote Internal Loopback Remote WinLink 1000 can be set to an internal loopback to test connection between the local and remote units, the local E1/T1 port and its connection to the local side user equipment. In this mode, data coming from the local WinLink 1000 is looped back to it (see Figure 5- 4). This loopback is initiated from a management station connected to the local unit. E1/T1 Interface E1/T1 Interface Testing Equipment Remote ODU Local ODU Management Station Figure 5-4. Remote Internal Loopback Remote External Loopback Remote WinLink 1000 can be set to an external loopback to test the remote E1/T1 port and its connection to the remote side user equipment. In this mode, data coming from the remote user equipment is looped back to it (see Figure 5-5). This loopback is initiated by an inband command sent from a management station connected to the local unit. PM Running Diagnostic Loopbacks 5-5 Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual E1/T1 Interface E1/T1 Interface Inband Loopback Activation Command Testing Equipment Remote ODU Local ODU Management Station Figure 5-5. Remote External Loopback Local Internal Loopback Local WinLink 1000 can be set to close an internal loopback to test connection between the local and remote units, remote E1/T1 port and its connection to the remote side user equipment. In this mode, data coming from the remote user equipment is looped back to it (see Figure 5-6). This loopback is initiated by an inband command sent from a management station connected to the local unit. E1/T1 Interface E1/T1 Interface Inband Loopback Activation Command Testing Equipment Remote ODU Local ODU Management Station Figure 5-6. Local Internal Loopback 5.4 Troubleshooting The WinLink 1000 LEDs show faults in the system or the link. Use Table 5-2 to diagnose the fault. 5-6 Troubleshooting WinLink 1000 Installation and Operation Manual Chapter 5 Diagnostics and Troubleshooting Table 5-2. Troubleshooting with WinLink 1000 LEDs Led Status Remedy PWR Off Check that AC adapter is connected to the IDU IDU Orange Check that the IDU/ODU cable is properly wired ODU Red AIR I/F Orange Complete the installation procedure from the Red Check the ODU Antenna alignment. Check that and the AC power outlet. and connected. Check that the IDU/ODU cable is properly wired and connected. management software. the radio configuration of both site A and site B units are the same (channel and SSID). SERVICE Off Check the TDM service configuration in the NMS. Orange Check that the system is not in loopback mode. Check the site B IDU ports and cables and site B external equipment. Red PM Check the site A IDU ports, cables and external equipment. Troubleshooting 5-7 Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual 5.5 Frequently Asked Questions Air Interface Q: What performance issues will arise due to environmental conditions? A: The WinLink 1000 is not sensitive to environmental conditions. However if heavy rain or snowfall is expected we can ensure the performance by allowing a higher fade margin in the budget link planning calculations. Q: When using the WinLink 1000, what is the potential for interference between our system and other cellular or wireless Networks devices? A: The WinLink 1000 is a robust system. However, since it operates in unlicensed band, there maybe some interference. Nevertheless, the fact that we can manually set the frequency gives us the flexibility to find a clear channel. In addition each WinLink 1000 link uses unique user configurable SSID code. Q: What protocol does the WinLink 1000 use, i.e. 802.11? A: WinLink 1000 uses a proprietary protocol; this protocol contains improved options that more efficiently support the clock reconstruction from the TDM services. Q: What type of security is offered on the WinLink 1000? A: The WinLink 1000 has two levels of security: Each unit uses a unique SSID - link specific code (up to 24 alphanumeric characters) Proprietary protocol protects from eavesdropping from other systems. Q: Can we use horizontal and vertical polarization on the same frequency to double the number of wireless links? A: Installing two WinLink 1000 systems in the same band with cross polarization provides 20–25 dB separations. Nevertheless, since there are reflections, the cross polarization separation is decreased and spatial separation is recommended. 5-8 Frequently Asked Questions WinLink 1000 Installation and Operation Manual Chapter 5 Diagnostics and Troubleshooting Q: In BAND C, can you add the frequency of 5.735 to the manual selection in order to increase the number of 20 MHz channels to six? A: Currently the system provides 5 fixed channels. Yet, the manual frequency setting provides more flexibility of spectrum selection, including 5.735 MHz. Q: Do we need to add external arrestors on WinLink 1000 cables? A: The WinLink 1000 ODU includes arrestors and lightning protection. Therefore there is no need to add additional arrestors. Q: What is the sensitivity for each rate of the WinLink 1000? A: The sensitivities are: Rate 12 Mbps -84 dB Rate 18 Mbps -81 dB Rate 36 Mbps -74 dB Rate 48 Mbps -68 dB Q: Does WinLink 1000 use DSSS technique? A: No, WinLink 1000 uses the advanced OFDM technique. Management Q: Can we mange WinLink 1000 using SNMP other then the supplied management software that comes with the units? A: Yes. The WinLink 1000 is SNMP based, when using other SNMP software, and after implementing RADWin MIB’s, the WinLink 1000 can be managed. PM Frequently Asked Questions 5-9 Chapter 5 Diagnostics and Troubleshooting WinLink 1000 Installation and Operation Manual Q: Can WinLink 1000 be managed and configured via Telnet? A: No. Use only the WinLink 1000 software manager. Q: After reselection Channel Reselection link is not established for long time. How can I recover the link? A: Click "cancel", then open the site configuration dialog and set the unit to install mode. The remote side of the link shall enter install mode on the installation channel. Services Q: What is the actual Ethernet data rate and maximum throughput? A: The Max net throughput of the WinLink 1000 is Full Duplex 18 Mbps. Note The WinLink 1000 is a symmetrical system Q: Does WinLink 1000 withhold any MAC Addresses? A: The WinLink 1000 is a layer 2 Bridge (VLAN transparent). The built in switch contains a MAC Address table up to 2047. Q: What are the BER values expected in the WinLink 1000 link? A: 1E-10 (according to BER sensitivity threshold) Antennas and Cables Q: Can I use any category 5e cable in order to connect the IDU and ODU? A: The cable should be suitable for outdoor use, and shielded Category 5e. Competitve 5-10 Frequently Asked Questions WinLink 1000 Installation and Operation Manual Chapter 5 Diagnostics and Troubleshooting Q: What are the main advantages of the WinLink 1000 solution (e.g., wireline, wireless, etc.) over other possible alternatives? A: Easy and intuitive installation using audio indication Easy configuration using the management software of overall link site to site – there is no need to travel between the two sites in order to change the configuration Easy migration between transition channels – site to site Full backup option – backup and restore using ini files Very light ODU (1.5 kg) No RF loses between IDU and ODU Robust Air Interface Layer 2 ARQ insures “error-free” Ethernet service even in harsh conditions. Retransmit mechanism for TDM insures low BER Integrated up to 4 E1/T1 and Ethernet radio over one single product. Supports a variety of applications Voice and Data over single radio – no need for external mediation device. Smooth migration to VoIP applications Carrier class compliant with ITU standards for E1 andT1 Low and constant TDM latency (8 msec) Extremely accurate recovered clock low cost replacement to PDH radios. 5.6 Technical Support Technical Support for this product can be obtained from the local distributor from whom it was purchased. PM Technical Support 5-11 Appendix A Wiring Specifications A.1 ODU-IDU Cable The ODU-IDU cable is standard CAT-5, 4 twisted-pair 24 AWG FTP. The ODU-IDU cable is terminated in RJ-45 connectors on both ends. It is covered by a cable gland on the ODU side for hermetic sealing. Table A-1 shows the connector pinout. Table A-1. ODU-IDU Cable Connector Pinout IDU RJ-45 Wire Color Function ODU RJ-45 Green/White Ethernet (RxN) Green Ethernet (RxT) Orange/White Ethernet (TxT) Blue Power (+) Blue/White Power (+) Orange Ethernet (TxN) Brown/White Power (−) Brown Power (−) Figure A-1. RJ-45 wiring for IDU-ODU cable ODU-IDU Cable A-1 Appendix A Wiring Specifications WinLink 1000 Installation and Operation Manual A.2 User Port Connectors The IDU includes ports for connecting E1/T1 and 10/100BaseT Ethernet user devices. Trunk Port The Trunk (E1/T1) interface terminates in an 8-pin RJ-45 balanced connector, wired in accordance to Table A-2. Table A-2. E1/T1 Connector Pinout Pin Function 4,5 Receive (input) 1,2 Transmit (output) LAN Port The LAN 10/100BaseT interface terminates in an 8-pin RJ-45 connector, wired in accordance to Table A-3. Table A-3. Fast Ethernet Connector Pinout Pin Signal Function TD (+) Transmit Data TD (–) Transmit Data RD (+) Receive Data RD (–) Receive Data (positive) (negative) (positive) (negative) A-2 IDU-C connectors WinLink 1000 Installation and Operation Manual Appendix A Wiring Specifications A.3 IDU-C connectors Table A-4. Terminal Block 3-pin -48VDC Pin Connection Right ‘+’ Center Chassis Left ‘-’ Table A-5. Alarm Connector (Dry-Contact) Pin Description Input #1 Positive Input #1 Negative Input #2 Positive Input #2 Negative Output #1 NC pin Output #1 COM pin Output #1 NO pin Output #2 COM pin Output #2 NO pin IDU-C connectors A-3 Appendix B Mast and Wall Installation B.1 Mounting the ODU The ODU can be mounted on a mast or a wall. ODU Mounting Kit Contents The ODU mounting kit includes the following items: • One Large Clamp (see figure B-1) • One Small Clamp (see figure B-2) • One Arm (see figure B-3) • Four Screw hex head M8x40 • Two Screw hex head M8x70 • Four Washer flat M8 • Three Washer spring M8 • Two M8 Nuts Figure B-1. Large Clamp Figure B-2. Small Clamp Figure B-3. Arm Mounting the ODU B-1 Appendix B Mast and Wall Installation Mounting WinLink 1000 on a Mast B-2 Mounting the ODU WinLink 1000 Installation and Operation Manual WinLink 1000 Installation and Operation Manual Appendix B Mast and Wall Installation Mounting WinLink 1000 on a Wall Mounting the ODU B-3 Appendix B Mast and Wall Installation B.2 WinLink 1000 Installation and Operation Manual Mounting an External Antenna The optional external antenna can be mounted on a mast. External Antenna Mounting Kit Contents The external antenna mounting kit includes the following items: Î • Twelve flat washers • Eight spring washers • Eight hex nuts • Four bolts • One U-bracket • One pivoting bracket • Two metal strap clamps. To install external antenna on the mast: 1. Attach the U-bracket to the back of the antenna using four flat washers, four spring washers and four hex nuts. 2. Attach the pivoting bracket to the U-bracket using eight flat washers, four spring washers, four hex nuts and four bolts. 3. Pass both strap clamps through the vertical slots in the pivoting bracket. 4. Attach the antenna to the mast using the two strap clamps. 5. Adjust the required tilt using the angular scale and tighten all bolts and nuts at the required position. B-4 Mounting an External Antenna Appendix C Link Budget Calculator C.1 Overview The Link Budget Calculator is a utility for calculating the expected performance of the WinLink wireless link and the possible configurations for a specific link range. The utility allows you to calculate the expected RSS of the link, and find the type of services and their effective throughput as a function of the link range and deployment conditions. The Link Budget Calculator is supplied on the WinLink Manager CD. After installation, it may also be accessed from the menu bar of the WinLink Manager (see Figure C-1). Overview Link Budget Calculator WinLink 1000 Figure C-1. Accessing the Link Budget Manager Calculator C.2 Using the Link Budget Calculator The Link Budget Calculator comprises of one table where all the link parameters are defined. Using the Link Budget Calculator WinLink 1000 Link Budget Calculator Figure C-2. Link Budget Screen Î To calculate the link budget 1. Select your WinLink system product from the dropdown list of products. 2. Select the rate from the dropdown list. The rate defines the airinterface rate in Mbps. The system operates in TDD mode and has overhead of the air-interface protocol and therefore the accurate actual throughput is provided in the ‘Service’ Row and the effective Ethernet throughput is provided in the ‘Ethernet Rate’. Note Throughput can be decreased as a function of range due to propagation delay. The remaining fields are completed automatically depending on the product selected in the product field. Standard WinLink system parameters are entered as default. Fields in blue boxes may be edited if non-standard antennas and cables are used. The Fade margin is the minimum margin that is required for LOS conditions. For degraded link conditions, a larger fade margin should be taken into account. Using the Link Budget Calculator Link Budget Calculator WinLink 1000 The Tx power EIRP for the system is given in dBm and Watts. 3. Select the required link distance and units of distance, kilometers or miles. 4. Click Calculate The Expected Performance parameters are calculated and displayed in the lower part of the table. Expected RSS – this is the number that the WinLink Manager software shows when the WinLink ODUs are best aligned. Services – Maximum E1/T1 services possible whilst maintaining full duplex Ethernet throughput. Ethernet Rate – Maximum throughput available with the chosen system. 5. If the expected performance is not suitable for your application, select a different data rate and re-calculate. Using the Link Budget Calculator Appendix D TDM Clock Configuration D.1 Overview This appendix describes the WINLink 1000 TDM clock configuration. The following picture describes the E1 or T1 service configuration. Figure D-1. E1 or T1 service configuration D.2 External clock requirements WINLink 1000 system assumes that all external equipments connected to a single site use the same transmit clock. In the picture above, E1 – 1 in (site A) and E1 – 2 in (site A) must use the same clock. E1 – 1 in (site B) and E1 – 2 in (site B) must also use the same clock, but this clock can be a different clock that used in site A. The system automatically selects a specific trunk for clocking according to the rules described below. External clock requirements D-1 TDM Clock Configuration D.3 WinLink 1000 Clock selection WINLink 1000 automatically selects a single trunk for the timing. The trunk is selected according to the following rules: • Smaller trunk number • Both ends line state is in Normal • Each line state change in the selected trunk re-triggers a new clock selection according the above rules. If the selected trunk is in Los of Signal state, the WINLink 1000 uses its internal clock. There are two methods to configure the user equipment. • Master / Slave mode – One of the sites is defined as the clock master while the other site is configured as a time loop (received clock) • Independent (Plesynchronous) Mode – Each site is configured as timing Master In both user configurations WINLink 1000 system re-generates the selected IN clock of the opposite site and use it as the OUT clock for all trunks. In case that there is no IN clock in the selected trunk, WINLink 1000 use its internal clock (and re-generate it in the opposite site as an OUT clock). Note D.4 It is user responsibility to verify that all IN clocks of a site are derived from a single clock source. Behavior in fault configuration Where there are different transmit clocks at the external equipments of the same site, pattern slips are expected. The pattern slip rate is proportional to the clock difference. For example if in site A E1 – 1 in clock is 2.048 Mb/s and E1 – 2 in clock is 2.048 Mb/s + 1 PPM and all trunks are in normal state, a pattern slip of up to 2000 bits is expected in trunk 2 every 1000 seconds. D-2 Behavior in fault configuration WinLink 1000 TDM Clock Configuration Example 1 Site A clocks: E1-1 IN and E1-2 IN differ, and all trunks are in normal condition, WINLink 1000 shall use trunk 1 for the timing and the second trunk shall experience pattern slips (the rate of the pattern slips is dependent on the ratio between the different clocks) Example 2 Trunk 1 is disconnected and trunk 2 is in normal condition. WINLink 1000 shall select trunk 2 for clock timing. Since trunk 1 is disconnected it uses an internal clock as an input clock. The OUT clock of both trunks is the re-generated clock IN 2, and therefore WINLink 1000 shall display error blocks on clock 1 (represents the clock difference between the internal clock and the IN 2 clock). Behavior in fault configuration D-3 Index —A— Air Interface Rate, 3-9, 2-16 Alarms, 4-1, 4-2, 4-4, 5-1, 5-7 list of, 5-2 Aligning the ODUs, 2-9 Antenna, 2-3 Connecting the Power, 2-6 Connectors IDU-C, A-3 user port, A-2 Contents, of package, 2-2 —D— automatic channel select, 3-5, 3-7, 2-13 Default gateway, 3-16 —B— Diagnostics, 5-1 Back panel, 4-1 Backup, 4-7 Buzzer. See Buzzer sequence DFS, 3-4, 3-6, 3-7, 2-12, 2-14 Displaying inventory, 4-8 —E— Buzzer sequence, 2-10 E1/T1 Connector Pinout, A-2 —C— External antenna, 2-3 Cable, ODU/IDU, 2-3 Calculator utility, 2-2 Change password, 4-4 Event log, 4-6, 5-1, 5-2 mounting, B-4 external equipment, D-1, D-2 Channel, selecting, 3-4, 2-12 —F— clock Fast Ethernet Connector Pinout, A-2 Clearing counters, 4-5 FAQ, 5-8 configuration, D-1 Fault configuration, D-2 external requirements, D-1 Frequency, 3-4, 2-13 examples, D-3 selection, D-2 transmit, D-2 clock configuration, D-1 clock master, D-2 clock selection, D-2 clocking, D-1 Configuration, 3-1 Frames rate, 4-6 Front panel, 4-1 —I— IDU, 2-2 Connecting the ODU to the IDU, 2-5 Connector panels, 4-1 Front and Back panels, 4-1 editing, 3-13 IDU-C, 2-3, 2-18 saving, 4-7 ODU/IDU Cable, 2-3 restoring, 4-8 Connecting the ODU to the IDU, 2-5 IDU-E, 2-2, 2-18 IN clock, D-2 I-1 Index Independent mode, D-2 Indications, 5-7 Indicators, 4-1, 4-2, 4-4 Information messages, 5-2 Installation, 2-1, 2-3, 2-4 of software, 2-7 performing, 2 prerequisites, 2 WinLink 1000 units, 1 Installation wizard, 2-10 Installing of the Link, 2-10 internal clock, D-2 example, D-3 Inventory, 4-8 IP address, 3-16 ISM frequencies, 2-13 —L— LAN Port, A-2 LEDs, 4-2, 4-4, 5-7 Link Budget Calculator, 2-2 overview, C-1 using, C-2 Link configuration, 3-2 Link details, 4-6 Link installation, 2-10 Log, 4-6, 5-1, 5-2 Loopback, 5-3 external, 5-4 internal, 5-5 Los of Signal, D-2 —M— Main menu, 4-5 WinLink 1000 Installation and Operation Manual ODU, 2-4 wall, B-3 —N— Normal line state, D-2 —O— ODU, 2-1, 2-2 Aligning, 2-9 Connecting the ODU to the IDU, 2-5 mounting, 2-4 ODU/IDU Cable, 2-3 Transmit Power, 3-15 ODU-IDU cable pinout, A-1 Operating channel, selecting, 3-4, 2-12 Operating temperature, 2-2 Operation, 4-1 OUT clock, D-2 example, D-3 Outdoor Unit (ODU) aligning, 2-9 buzzer, 2-9 mounting, B-1 —P— Package contents, 2-2 Password changing, 4-4 default, 2-9 pattern slips, D-2 example, D-3 Pinout E1/T1 Connector, A-2 Fast Ethernet Connector, A-2 Maintenance, 4-7 Plesynchronous mode, D-2 Management addresses, 3-15 Power, of transmission, 3-15 Manual frequency, 2-13 PPM, D-2 Management, 4-5 Power, connecting, 4-3, 2-6 Management software, 2-7 Power, turning off, 4-4 Master mode, D-2 Prerequisites, 2-2 Monitor pane, 4-6 —Q— Monitor log, 5-2 Mounting mast, B-2 I-2 Quality bar, 2-13 Quick start, 1 WinLink 1000 Installation and Operation Manual —R— Radio link status, 4-6 Radio signal strength, 4-6 Rate, selecting, 3-9, 2-16 Index Temperature, operating, 2-2 timing, D-2 examples, D-3 Toolbar, 4-5 ratio TPC, 3-6, 3-7, 2-14 Requirements, 2-2, 2-7 transmit clock, D-1, D-2 different clocks, D-3 Reset, 4-7 Restoring configuration, 4-8 re-triggers, D-2 —S— Saving the configuration, 4-7 Selecting the channel, 3-4, 2-12 Service parameters, 3-10 Setup, 2-1, 2-3 of software, 2-7 Site Requirements, 2-2 Slave mode, D-2 slips pattern, D-2, D-3 Software, 2-7 Traffic rate, 4-6 Transmit Power, 3-15 Trap destination, 3-16 Troubleshooting, 5-1, 5-7 trunk number, D-2 Trunk Port, A-2 Turning off, 4-4 Turning on, 4-3 Typical installation, 2-4 —U— User equipment connecting, 3 User port connectors, A-2 SSID, 2-12 —W— Subnet mask, 3-16 WinLink 1000 units Statistics, 4-6, 5-2 Support, 5-11 System, 2-1 —T— WinLink 1000 System, 2-1 installing, 1 normal indications, 4 operating, 4 troubleshooting, 5 Technical support, 5-11 I-3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:04:13 13:26:45+03:00 Modify Date : 2005:08:04 11:05:00+02:00 Tagged PDF : No Page Mode : UseOutlines Producer : Acrobat Distiller 7.0 (Windows) Mod Date : 2005:08:04 11:05:00+02:00 Creation Date : 2005:04:13 13:26:45+03:00 Author : Sara Elizedek Metadata Date : 2005:08:04 11:05:00+02:00 Creator Tool : Acrobat PDFMaker 7.0 for Word Document ID : uuid:e82e746f-c48c-47d9-b100-58d44fe026bd Instance ID : uuid:d31b57fb-2c72-4b4e-b339-e360cc4675cc Format : application/pdf Title : WinLink 1000 Creator : Sara Elizedek Has XFA : No Page Count : 98 Page Layout : SinglePageEXIF Metadata provided by EXIF.tools