Radwin RW2058 Outdoor radio unit operating in 5.8 GHz band User Manual STW

Radwin Ltd. Outdoor radio unit operating in 5.8 GHz band STW

Contents

Manual

Download: Radwin RW2058 Outdoor radio unit operating in 5.8 GHz band User Manual STW
Mirror Download [FCC.gov]Radwin RW2058 Outdoor radio unit operating in 5.8 GHz band User Manual STW
Document ID1450259
Application IDqufvPS54zzu1WLBoM63e6w==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize246.61kB (3082621 bits)
Date Submitted2011-04-19 00:00:00
Date Available2011-04-19 00:00:00
Creation Date2011-04-10 12:04:54
Producing SoftwareAcrobat Distiller 10.0.1 (Windows)
Document Lastmod2011-04-10 14:28:05
Document TitleSTW
Document CreatorFrameMaker 10.0
Document Author: DAF

RADWIN 1000/2000/5000
Broadband Wireless
Transmission System
User Manual
Version 2.5.30p3
UM 5000-2530/04.11
RADWIN 1000/2000/5000
User Manual
Notice
This manual contains information that is proprietary to RADWIN Ltd. (RADWIN hereafter). No
part of this publication may be reproduced in any form whatsoever without prior written
approval by RADWIN.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and
other intellectual property or other proprietary rights relating to this manual and to the
RADWIN products and any software components contained therein are proprietary products
of RADWIN protected under international copyright law and shall be and remain solely with
RADWIN.
The RADWIN name is a registered trademark of RADWIN Ltd. No right, license, or interest to
such trademark is granted hereunder, and you agree that no such right, license, or interest
shall be asserted by you with respect to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the User Manual
or any other RADWIN documentation or products. You are prohibited from, and shall not,
directly or indirectly, develop, market, distribute, license, or sell any product that supports
substantially similar functionality based or derived in any way from RADWIN products.Your
undertaking in this paragraph shall survive the termination of this Agreement.
This Agreement is effective upon your opening of a RADWIN product package and shall
continue until terminated. RADWIN may terminate this Agreement upon the breach by you of
any term thereof. Upon such termination by RADWIN, you agree to return to RADWIN any
RADWIN products and documentation and all copies and portions thereof.
For further information contact RADWIN at the address below or contact your local
distributor.
Disclaimer
The parameters quoted in this document must be specifically confirmed in writing before they
become applicable to any particular order or contract. RADWIN reserves the right to make
alterations or amendments to the detail specification at its discretion. The publication of
information in this document does not imply freedom from patent or other rights of RADWIN,
or others.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
RADWIN Worldwide Offices
Corporate Headquarters
India Headquarters
27 Habarzel Street
Tel Aviv, 69710
Israel
Tel: +972 3 766 2917
Mohan Co-operative Industrial Estate
E-13, B-1 Extn
New Delhi, 110044
India
Tel: +91 11 4053 9180
Support Headquarter
27 Habarzel Street
Tel Aviv, 69710
Israel
Tel: +972 3 766 2900
Mobile: +972 54 766 0044
APAC Headquarters
1 Jalan Kuala #13-01
The Morningside, 239639
Singapore
Tel: +65 9878 3004
RADWIN North America
Indonesia Sales Office
900 Corporate Drive
Mahwah, NJ 07430
USA
Tel (1): 1 800 444 7234 / 341
Tel (2): +1 201 529 1100 / 341
Jl. Jenderal Sudirman Kav. 86
Jakarta, 10220
Indonesia
Tel: +62 8138 570 0657
Latin America Headquarters
Rua Grao Mogol 828
Belo Horizonte, MG 30310-010
Brazil
Tel (1): +55 31 919 76 402
Tel (2): +972 54 758 6808
Philippines Sales Office
37A. A luna St. West Rembo
Makati City, 1200
Philippines
Tel: +63 2882 6886
Mobile: +63 91 789 23427
China Sales Office
Asian Games Village
Huiyuan Gongyu J1312
Beijing 100101
China
Tel: +86 010 8498 0629
For technical support contact: support@radwin.com
For technical support in India only, contact: support-india@radwnin.com
For sales support contact: sales@radwin.com
Website: www.radwin.com
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
ii
Regulatory Compliance
General Note
This system has achieved Type Approval in various countries around the world. This means
that the system has been tested against various local technical regulations and found to
comply. The frequency bands in which the system operates may be “unlicensed” and in these
bands, the system can be used provided it does not cause interference.
FCC/IC - Compliance
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules and ICES-003 of IC. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible
for compliance (RADWIN Ltd.) could void the user's authority to operate the equipment.
Warning
Caution
Caution
It is the responsibility of the installer to ensure that when using the outdoor
antenna kits in the United States (or where FCC rules apply), only those
antennas certified with the product are used. The use of any antenna other
than those certified with the product is expressly forbidden in accordance to
FCC rules CFR47 part 15.204.
In accordance to IC standard RSS-Gen - To reduce potential radio
interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p) is not more
than that permitted for successful communication
Outdoor units and antennas should be installed ONLY by experienced
installation professionals who are familiar with local building and safety
codes and, wherever applicable, are licensed by the appropriate government
regulatory authorities. Failure to do so may void the product warranty and
may expose the end user or the service provider to legal and financial
liabilities. Resellers or distributors of this equipment are not liable for injury,
damage or violation of regulations associated with the installation of outdoor
units or antennas. The installer should configure the output power level of
antennas according to country regulations and antenna type.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
iii
Warning
Warning
The antenna used for this transmitter must be installed to provide a
separation distance of at least 225cm from all persons and must not be colocated or operated in conjunction with any other antenna or transmitter.
This product was tested with special accessories - indoor unit (IDU or
PoE), FTP Cat 5e shielded cable with sealing gasket, 12 AWG grounding
cable - which must be used with the unit to insure compliance.
Indoor Units comply with part 15 of the FCC rules and ICES-003 standard. Operation is
subject to the following two conditions:
(1) These devices may not cause harmful interference.
(2) These devices must accept any interference received, including interference that may
cause undesired operation.
Canadian Emission Requirements for Indoor Units
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numẻrique de la classe B est conforme ả la norme NMB-003 du Canada.
Safety Practices
Applicable requirements of National Electrical Code (NEC), NFPA 70; and the National
Electrical Safety Code, ANSI/IEEE C2, must be considered during installation.
NOTES:
1. A Primary Protector is not required to protect the exposed wiring as long as the exposed
wiring length is limited to less than or equal to 140 feet, and instructions are provided to
avoid exposure of wiring to accidental contact with lightning and power conductors in
accordance with NEC Sections 725-54 (c) and 800-30.
In all other cases, an appropriate Listed Primary Protector must be provided. Refer to Articles
800 and 810 of the NEC for details.
2. For protection of ODU against direct lightning strikes, appropriate requirements of NFPA
780 should be considered in addition to NEC.
3. For Canada, appropriate requirements of Section 60 of the CEC 22.1should be considered
as applicable.
4. E1/T1 ports are intended for connection to indoor lines only and are not exposed to
outdoor plants.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
iv
Table of Contents
Notice ....................................................................................................................... i
RADWIN Worldwide Offices.................................................................................... ii
Regulatory Compliance .............................................................................................. iii
Chapter 1 Introduction
Welcome! .............................................................................................................. 1-1
Key Applications ..................................................................................................... 1-2
WiMAX and IP Backhaul..............................................................................1-2
Broadband Access .......................................................................................1-2
Private Networks ........................................................................................1-3
Key Features of RADWIN 1000/2000/5000 ............................................................... 1-3
RADWIN 1000/2000/5000 Link ................................................................................ 1-5
The Radio Outdoor Unit (ODU) ...................................................................1-6
The Indoor Units (IDU) ...............................................................................1-8
IDU-C......................................................................................................................... 1-8
IDU-E ......................................................................................................................... 1-9
Power Over Ethernet (PoE) Devices ...........................................................1-9
Antennas ...................................................................................................1-10
Flat Panel Antennas................................................................................................... 1-11
Parabolic Dish Antennas............................................................................................. 1-12
RADWIN Manager .....................................................................................1-12
Accessories................................................................................................1-13
Documentation set supplied with RADWIN 1000/2000/5000 .................1-13
How to Use this Manual ........................................................................................ 1-14
A Little Terminology ............................................................................................. 1-14
Conventions Used in this Manual ........................................................................... 1-16
Notifications..............................................................................................1-16
Typographical conventions .......................................................................1-16
General .................................................................................................................... 1-16
Software................................................................................................................... 1-16
Windows Terminology ..............................................................................1-17
Chapter 2 Site Preparation
Planning the Link Site ............................................................................................. 2-1
Overview ..................................................................................................... 2-1
The Site Survey...................................................................................................... 2-1
Introduction ................................................................................................2-1
Recommended Equipment ..........................................................................2-1
Stage 1: Preliminary Survey .................................................................................... 2-2
Stage 2: Physical Survey ......................................................................................... 2-3
Additional Outdoor Site Requirements .......................................................2-4
Additional Indoor Site Requirements .........................................................2-4
Stage 3: RF Survey................................................................................................. 2-4
Chapter 3 Hardware Installation
Safety Practices...................................................................................................... 3-1
Preventing overexposure to RF energy ......................................................3-1
Grounding ...................................................................................................3-1
Protection against Lightning.......................................................................3-2
General........................................................................................................ 3-2
Package Contents................................................................................................... 3-2
ODU Package Contents ...............................................................................3-2
IDU Package Contents ................................................................................3-4
External Antenna Package Contents...........................................................3-5
Additional Tools and Materials Required ................................................................... 3-5
Tools and Materials .....................................................................................3-5
Cables and connectors ................................................................................3-5
Hardware Installation Sequence .............................................................................. 3-5
Outdoor installation ................................................................................................ 3-6
Mounting the ODU.......................................................................................3-6
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
Mounting external antennas .......................................................................3-7
Mounting the Lightning Protection Devices................................................3-7
Outdoor Connections ..................................................................................3-8
Indoor Installation.................................................................................................. 3-8
IDU-E Installation........................................................................................................ 3-8
Mounting the IDU-C ....................................................................................3-8
Connecting power to the IDU ...................................................................3-11
Connecting the ODU to the IDU ................................................................3-12
Installing a Link using PoE Devices ..........................................................3-12
Connecting User Equipment......................................................................3-12
Connecting and Aligning ODUs / Antennas ............................................................. 3-13
Chapter 4 Link Installation: The RADWIN Manager
Installing theRADWIN Manager Application .............................................................. 4-1
Minimum System Requirements .................................................................4-1
Installing the Software ...............................................................................4-1
Starting the RADWIN Manager ................................................................................ 4-2
Login Errors ........................................................................................................... 4-5
Unsupported Device....................................................................................4-5
Incorrect IP Address ...................................................................................4-6
Incorrect Password.....................................................................................4-6
Continuing without an IP Address ............................................................................ 4-6
Changing the Log On Password ..................................................................4-7
Installing the Link: First steps.................................................................................. 4-7
Default Settings ..........................................................................................4-9
Front Panel LEDs on the IDU-C ...................................................................4-9
Installation Menu and Toolbar Functionality ............................................4-10
Installing the Link: Overview ................................................................................. 4-13
Installing the Link: Step 1, Start the Wizard ........................................................... 4-14
Installing the Link: Step 2, System Parameters ....................................................... 4-14
Changing the Link Password.....................................................................4-16
Installing the Link: Step 3, Channel Settings........................................................... 4-17
Installing the Link: Step 4, Tx Power and Antenna Settings ..................................... 4-19
General......................................................................................................4-20
Dual Antennas at Both Sites .....................................................................4-20
Single Antennas at Both Sites...................................................................4-21
Single and Dual Antennas .........................................................................4-21
Considerations for Changing Antenna Parameters...................................4-22
Installing the Link: Step 5, Services ....................................................................... 4-25
Installing the Link: Step 6, Installation Summary and Exit ....................................... 4-26
Chapter 5 Configuring the Link
Link Configuration: Getting Started .......................................................................... 5-1
The Main Window of the RADWIN Manager ...............................................5-1
The RADWIN Manager Toolbar ...................................................................5-2
The RADWIN Manager Main Menu..............................................................5-3
Elements of the RADWIN Manager Main Window ......................................5-6
Configuring the Link: Overview.............................................................................. 5-10
Configuring the Link: Step 1, Start the Wizard ........................................................ 5-11
Configuring the Link: Step 2, System Parameters.................................................... 5-11
Configuring the Link: Step 3, Channel Settings ....................................................... 5-12
Configuring the Link: Step 4, Tx Power and Antenna Settings .................................. 5-18
Configuring the Link: Step 5, Services .................................................................... 5-20
Configuring the Link: Step 6, Configuration Summary and Exit................................. 5-21
Chapter 6 Site Configuration
Configuring the Site................................................................................................ 6-1
Editing the Configuration Parameters by Site ............................................6-1
Functions on the left of the dialog box: .........................................................................6-2
Functions at the top of the dialog box:..........................................................................6-2
Viewing Air Interface Details ................................................................................... 6-3
Changing the Transmit Power ................................................................................. 6-4
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
vi
Site Management: IP Address and VLAN .................................................................. 6-4
Configuring the ODU Address .....................................................................6-4
Configuring VLAN Settings..........................................................................6-5
Lost or forgotten VLAN ID............................................................................................6-7
Setting the Date and Time ...................................................................................... 6-7
Ethernet Properties................................................................................................. 6-9
Configuring the Bridge................................................................................6-9
ODU Mode ................................................................................................................ 6-10
IDU Aging time ......................................................................................................... 6-10
Configuring Ethernet Ports Mode .............................................................6-11
Setting the Maximum Information Rate ...................................................6-12
Displaying the Inventory ....................................................................................... 6-12
Security Features ................................................................................................. 6-13
Changing the Link Password.....................................................................6-14
RADWIN Manager Community Strings .....................................................6-14
Editing Community Strings ......................................................................................... 6-15
Forgotten Community string....................................................................................... 6-16
Muting the alignment tone .................................................................................... 6-17
Setting External Alarm Inputs................................................................................ 6-17
Managing Configuration Files................................................................................. 6-18
Backup Configuration to a File..................................................................6-18
Restoring a Configuration File ..................................................................6-19
Resetting...................................................................................................6-19
Configuration with Telnet...................................................................................... 6-20
Chapter 7 Monitoring and Diagnostics
Retrieving Link Information (Get Diagnostics)........................................................... 7-1
Link Compatibility ................................................................................................... 7-3
Reinstalling and Realigning a Link............................................................................ 7-3
The Link Budget Calculator ..................................................................................... 7-4
Performance Monitoring.......................................................................................... 7-4
The Monitor Log ..........................................................................................7-4
Saving the Monitor Log ................................................................................................7-4
Viewing Performance Reports.......................................................................................7-5
Performance Monitoring Report Toolbar ........................................................................7-9
Setting Air Interface Thresholds ...................................................................................7-9
The Events Log ..........................................................................................7-10
RADWIN Manager Traps ...........................................................................7-11
Setting the Events Preferences ................................................................................... 7-12
Saving the Events Log ............................................................................................... 7-13
Reverting Alarm Messages ......................................................................................... 7-14
Active Alarms ............................................................................................................ 7-14
Remote Power Fail Indication ..................................................................................... 7-15
Troubleshooting ................................................................................................... 7-16
Replacing an ODU ................................................................................................ 7-16
Restoring Factory Setup........................................................................................ 7-17
Online Help.......................................................................................................... 7-17
Customer Support ................................................................................................ 7-17
Appendix A Technical Specifications
Configuration ........................................................................................................ A-1
Radio ................................................................................................................... A-2
Ethernet Interface ................................................................................................. A-4
Management......................................................................................................... A-5
Mechanical............................................................................................................ A-5
Power................................................................................................................... A-5
Environmental....................................................................................................... A-5
Safety................................................................................................................... A-5
EMC ..................................................................................................................... A-5
Air Interface.......................................................................................................... A-5
Appendix B Wiring Specifications
ODU-IDU Cable ..................................................................................................... B-1
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
vii
User Port Connectors............................................................................................ B-1
LAN Port ......................................................................................................B-1
IDU-C Alarm Connector ..............................................................................B-3
Appendix C Pole and Wall Installation
ODU Mounting Kit Contents.................................................................................... C-1
Mounting RADWIN 1000/2000/5000 on a pole......................................................... C-2
Mounting RADWIN 1000/2000/5000 on a Wall......................................................... C-3
Mounting an External Antenna ............................................................................... C-3
Appendix D Link Budget Calculator
Overview .............................................................................................................. D-1
User Input .................................................................................................. D-1
Link Budget Calculator Internal Data ........................................................ D-1
Calculations .......................................................................................................... D-2
EIRP ........................................................................................................... D-2
Expected RSS and Fade Margin.................................................................. D-2
Min and Max Range.................................................................................... D-2
Service ....................................................................................................... D-2
Availability ................................................................................................. D-2
Antenna Height .......................................................................................... D-3
Running the Link Budget Calculator ........................................................................ D-3
About the Fresnel Zone........................................................................................ D-13
Appendix E Lightning Protection and Grounding Guidelines
Grounding for Antenna Cable ................................................................................. E-1
Grounding for Indoor/Outdoor Units ....................................................................... E-2
ODU Grounding ........................................................................................... E-2
IDU Grounding ............................................................................................ E-2
External Lightning Surge Suppressors and Grounding............................................... E-3
Internal ESD Protection circuits .............................................................................. E-7
Appendix F MIB Reference
Introduction........................................................................................................... F-1
About the MIB ............................................................................................. F-1
Terminology ................................................................................................ F-1
Interface API ......................................................................................................... F-1
Control Method ........................................................................................... F-1
Community String ....................................................................................... F-2
Private MIB Structure.............................................................................................. F-2
MIB Parameters ..................................................................................................... F-4
Supported Variables from the RFC 1213 MIB ............................................. F-4
MIB Parameters .......................................................................................... F-5
MIB Traps............................................................................................................ F-18
General...................................................................................................... F-18
Trap parameters........................................................................................ F-18
RADWIN Manager Traps ........................................................................... F-21
Appendix G External Alarms Specification
External Alarms Specification.................................................................................. G-1
Appendix H Combo Configuration Tool
What is the Combo Configuration Tool? .................................................................. H-1
Who may use the Combo Configuration Tool ........................................................... H-1
Caveat to the use of the Combo Configuration Tool ................................................. H-1
Prerequisites to using the Combo Configuration Tool................................................ H-2
Operating the Combo Configuration Tool................................................................. H-2
Before using the Combo Configuration Tool............................................................. H-2
Using the Combo Configuration Tool ....................................................................... H-2
If you receive an error message ............................................................................. H-6
Appendix I Regional Notice: French Canadian
Procédures de sécurité............................................................................................ I-1
Généralités .................................................................................................. I-1
Mise à la terre ............................................................................................. I-1
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
viii
Protection contre la foudre ......................................................................... I-2
Précautions de sécurité pendant le montage de ODU ................................ I-2
Connecter la terre à IDU-C ......................................................................... I-3
Installation sur pylône et mur.................................................................................. I-4
Contenu du kit de montage ODU ................................................................ I-4
Montage sur un pylône ............................................................................... I-5
Montage sur un mur.................................................................................... I-6
Montage d'une antenne externe ................................................................. I-7
Contenu du kit de montage d'une antenne externe ................................... I-7
Index
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
ix
List of Figures
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
1-1 TYPICAL WIMAX AND IP BACKHAUL APPLICATION ....................................................1-2
1-2 TYPICAL BROADBAND ACCESS APPLICATION ...........................................................1-3
1-3 PRIVATE NETWORK ..........................................................................................1-3
1-4 EXAMPLE OF LINK ARCHITECTURE - SYSTEM COMPONENTS ........................................1-6
1-5 ODU FORM FACTORS .......................................................................................1-7
1-6 IDU-C FRONT PANEL .......................................................................................1-9
1-7 IDU-E - FRONT VIEW.......................................................................................1-9
1-8 IDU-E: REAR PANEL ........................................................................................1-9
1-9 POE DEVICE - SHOWING THE RADIO ETHERNET PORT .............................................1-10
1-10 ODU WITH INTEGRATED FLAT PANEL ANTENNA...................................................1-10
1-11 FLAT PANEL ANTENNA ..................................................................................1-11
1-12 EXTERNAL ANTENNAS - PARABOLIC DISH...........................................................1-12
1-13 RADWIN MANAGER SCREEN ..........................................................................1-13
1-14 SITE CONFIGURATION WINDOW WITH OPEN MANAGEMENT PANEL ............................1-18
3-1 ODU MOUNTING KIT .......................................................................................3-3
3-2 CONNECTORIZED ODU - FRONT AND REAR VIEWS ...................................................3-3
3-3 INTEGRATED ODU - FRONT AND REAR VIEWS ........................................................3-4
3-4 IDU-C PACKAGE CONTENTS - THE IDU-C .............................................................3-4
3-5 IDU-C PACKAGE CONTENTS - THE MOUNTING KIT AND DC POWER PLUGS .....................3-4
3-6 TYPICAL INSTALLATION DIAGRAM (WITH EXTERNAL ANTENNA)....................................3-6
3-7 NEW STYLE IDU-E: REAR PANEL ........................................................................3-8
3-8 IDU-C FRONT PANEL .......................................................................................3-9
3-9 IDU-C - A PERSPECTIVE VIEW ...........................................................................3-9
3-10 IDU-C LEDS .............................................................................................3-10
3-11 DU-C OWER CONNECTORS .............................................................................3-12
3-12 BEEP SEQUENCE FOR ANTENNA ALIGNMENT ........................................................3-14
4-1 LAN PORTS ON THE FRONT PANEL OF THE IDU-C ...................................................4-2
4-2 PINGING AN UNINSTALLED AND UNCONFIGURED LINK ................................................4-3
4-3 LOGIN SCREEN ...............................................................................................4-3
4-4 LOGIN SCREEN WITH COMMUNITY OPTIONS VISIBLE .................................................4-5
4-5 UNSUPPORTED DEVICE MESSAGE..........................................................................4-5
4-6 UNREACHABLE DEVICE MESSAGE ..........................................................................4-6
4-7 OPENING RADWIN MANAGER WINDOW PRIOR TO INSTALLATION ...............................4-8
4-8 IDU-C FRONT PANEL LEDS.............................................................................4-10
4-9 LINK INSTALLATION WIZARD ............................................................................4-14
4-10 : INSTALLATION WIZARD, SYSTEM DIALOG BOX ..................................................4-15
4-11 CHANGE LINK PASSWORD DIALOG BOX..............................................................4-16
4-12 LOST OR FORGOTTEN LINK PASSWORD RECOVERY................................................4-17
4-13 CHANNEL SETTINGS - AUTOMATIC CHANNEL SELECTION........................................4-18
4-14 CHANNEL SETTINGS - SHOWING AVAILABLE INSTALLATION RATES ............................4-19
4-15 TRANSMISSION POWER AND ANTENNA PARAMETERS .............................................4-20
4-16 ANTENNA CONFIGURATION DIALOG WITH OPENED TYPE SELECTION .........................4-23
4-17 ANTENNA PARAMETERS CHANGE WARNING ..........................................................4-24
4-18 TX POWER LIMITS .......................................................................................4-24
4-19 SERVICES AND RATES DIALOG.........................................................................4-25
4-20 INSTALLATION WIZARD EXIT SUMMARY.............................................................4-26
4-21 MAIN WINDOW OF THE MANAGER AFTER INSTALLATION .........................................4-27
5-1 MAIN WINDOW, WIRELESS LINK IS ACTIVE...........................................................5-2
5-2 ETHERNET BANDWIDTH INDICATION ....................................................................5-8
5-3 LINK CONFIGURATION WIZARD .........................................................................5-11
5-4 CONFIGURATION WIZARD, SYSTEM DIALOG BOX....................................................5-12
5-5 CHANNEL SETTINGS DIALOG BOX - AUTOMATIC CHANNEL SELECTION .........................5-13
5-6 SEARCHING FOR THE BEST OPERATING CHANNEL ...................................................5-14
5-7 CHANNEL SETTINGS WITHOUT AUTOMATIC CHANNEL SELECTION ................................5-15
5-8 CHANNEL FREQUENCY OPTIONS .........................................................................5-16
5-9 CHOOSING AN “OTHER” OPERATING CHANNEL FREQUENCY ......................................5-17
5-10 TRANSMISSION POWER AND ANTENNA PARAMETERS .............................................5-18
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
FIGURE
5-11 ANTENNA CONFIGURATION DIALOG WITH OPENED TYPE SELECTION .........................5-19
5-12 SERVICES AND RATES DIALOG.........................................................................5-20
5-13 CONFIGURATION WIZARD EXIT SUMMARY ..........................................................5-21
5-14 MAIN WINDOW OF THE MANAGER AFTER CONFIGURATION ......................................5-22
6-1 CONFIGURATION DIALOG BOX ............................................................................6-2
6-2 AIR INTERFACE DETAILS ....................................................................................6-3
6-3 CHANGING THE TRANSMIT POWER .......................................................................6-4
6-4 MANAGEMENT ADDRESSES - SITE CONFIGURATION DIALOG BOX ..................................6-5
6-5 CONFIGURING MANAGEMENT TRAFFIC VLAN SETTINGS .............................................6-6
6-6 DATE AND TIME CONFIGURATION ........................................................................6-8
6-7 CHANGE DATE AND TIME ..................................................................................6-8
6-8 DATE AND TIME CONFIGURED FROM AN NTP SERVER ...............................................6-9
6-9 BRIDGE CONFIGURATION - SITE CONFIGURATION DIALOG BOX .................................6-10
6-10 INVENTORY SCREEN .....................................................................................6-13
6-11 AVAILABLE SECURITY FEATURES .......................................................................6-14
6-12 CHANGING THE COMMUNITY STRING ................................................................6-16
6-13 ALTERNATIVE COMMUNITY DIALOG BOX ............................................................6-17
6-14 EXTERNAL ALARM CONFIGURATION ..................................................................6-18
6-15 TELNET MANAGEMENT SCREEN .......................................................................6-22
7-1 GET DIAGNOSTICS DIALOG BOX .........................................................................7-2
7-2 PREFERENCES DIALOG BOX.................................................................................7-5
7-3 BASIC PERFORMANCE MONITORING REPORT ..........................................................7-6
7-4 A TYPICAL PERFORMANCE MONITORING REPORT .....................................................7-6
7-5 THRESHOLD CONFIGURATION DIALOG BOX .............................................................7-9
7-6 EVENTS LOG DISPLAY.....................................................................................7-10
7-7 PREFERENCES DIALOG BOX...............................................................................7-13
7-8 ACTIVE ALARMS SUMMARY ..............................................................................7-15
7-9 ONLINE HELP FOR RADWIN 1000/2000/5000 ..................................................7-17
B-1 EXAMPLE FOR CONNECTING THE ALARM CONNECTOR................................................ B-4
C-4 MOUNTING ON A POLE..................................................................................... C-2
C-5 MOUNTING ON A WALL ................................................................................... C-3
D-1 ACCESSING THE LINK BUDGET CALCULATOR ......................................................... D-4
D-2 LINK BUDGET SCREEN ..................................................................................... D-5
D-3 PRODUCT SELECTOR ....................................................................................... D-7
D-4 RATE SELECTOR ............................................................................................. D-8
D-5 CALCULATION OF DISTANCE FROM SITE COORDINATES ............................................ D-9
D-6 CLIMACTIC C FACTORS .................................................................................. D-10
D-7 CLIMACTIC C FACTOR DESCRIPTION ................................................................. D-11
D-8 WORLD MAP SHOWING C FACTOR CONTOURS ..................................................... D-12
D-9 FRESNEL ZONE ............................................................................................ D-13
E-1 GROUNDING ANTENNA CABLES ........................................................................... E-2
E-2 GROUNDING A TYPICAL POLE INSTALLATION .......................................................... E-3
E-3 GROUNDING A TYPICAL WALL INSTALLATION.......................................................... E-4
E-4 ODU SURGE SUPPRESSOR AND GROUNDING.......................................................... E-4
E-5 TRANSTECTOR’S SURGE SUPPRESSOR .................................................................. E-5
E-6 SURGE SUPPRESSOR AND GROUNDING AT BUILDING ENTRY POINT............................... E-7
F-1 TOP LEVEL SECTIONS OF THE PRIVATE MIB...........................................................F-3
I-4 MONTAGE SUR UN PYLÔNE ................................................................................. I-5
I-5 MONTAGE SUR UN MUR ..................................................................................... I-6
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
xi
List of Tables
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
TABLE
1-1 AVAILABLE ODU PRODUCTS - RELEASE 2.5.30P3 ....................................................1-8
1-2 RELEASE 2.1 IDU-C PRODUCTS ...........................................................................1-8
3-1 COMPONENTS OF AN IDU-C FRONT PANEL ............................................................3-10
3-2 IDU-C FRONT PANEL LEDS ..............................................................................3-11
4-1 PC REQUIREMENTS FOR THE RADWIN MANAGER APPLICATION ...................................4-1
4-2 RADWIN MANAGER: OFFLINE FUNCTIONALITY ........................................................4-7
4-3 DEFAULT SETTINGS ...........................................................................................4-9
4-4 FRONT PANEL LEDS ........................................................................................4-10
4-5 RADWIN MANAGER MAIN MENU FUNCTIONALITY ...................................................4-11
4-6 RADWIN MANAGER TOOLBAR ..........................................................................4-12
4-7 LINK INSTALLATION WIZARD .............................................................................4-13
4-8 RADWIN 1000/2000/5000 TRANSMISSION RATES ...............................................4-22
5-1 RADWIN MANAGER TOOLBAR ............................................................................5-3
5-2 RADWIN MANAGER MAIN MENU FUNCTIONALITY .....................................................5-4
5-3 LINK DETAILS ..................................................................................................5-6
5-4 LINK SITE DETAILS, SITE A AND SITE B .................................................................5-7
5-5 STATUS BAR INDICATORS ....................................................................................5-9
5-6 LINK CONFIGURATION WIZARD ..........................................................................5-10
6-1 ODU MODE CONFIGURATION FOR COMMON ...........................................................6-11
6-2 TELNET COMMANDS.........................................................................................6-20
7-1 GET DIAGNOSTICS DATA AND DESCRIPTION ............................................................7-2
7-2 LINK COMPATIBILITY TRAP MESSAGES ...................................................................7-3
7-3 EXPLANATION OF PERFORMANCE DATA....................................................................7-8
7-4 ACTION OF THE TOOLBAR BUTTONS .......................................................................7-9
7-5 RADWIN MANAGER TRAP MESSAGES..................................................................7-11
7-6 ACTIVE ALARMS COMMAND BUTTONS ...................................................................7-15
7-7 LED FAULT INDICATORS ...................................................................................7-16
7-8 TROUBLESHOOTING .........................................................................................7-16
B-1 ODU-IDU CONNECTOR PINOUT.......................................................................... B-1
B-2 FAST ETHERNET CONNECTOR PINOUT ................................................................... B-2
B-3 IDU-C ALARM CONNECTOR (DRY-CONTACT) ......................................................... B-3
B-4 TERMINAL BLOCK 3-PIN -48VDC ........................................................................ B-4
C-1 BILL OF MATERIALS: ODU MOUNTING KIT ............................................................. C-1
F-1 SUPPORTED RFC 1213 VARIABLES .......................................................................F-4
F-2 PRIVATE MIB PARAMETERS .................................................................................F-5
F-3 MIB TRAPS ................................................................................................... F-18
G-1 OUTPUT ALARMS PINOUT .................................................................................. G-1
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
xii
Chapter 1
Introduction
Welcome!
Welcome to the RADWIN 1000/2000/5000 radio series, designed for the IP
and WiMAX Backhaul, Private Networks and Broadband Access global markets. The RADWIN 1000/2000/5000 series is an innovation in high-capacity
carrier-grade sub-6GHz radios, and designed to meet the requirements of
current and next-generation markets and applications. RADWIN 1000/2000/
5000 also features software configurable antenna port activation enabling
single (RADWIN 1000) or dual (RADWIN 2000) antenna port operation. The
RADWIN 5000 series is identifier for software configured Point to Multipoint
devices. The device configured as RADWIN 2000 has an advanced air-interface based on MIMO, antenna diversity.
The RADWIN 1000/2000 radio series offers unmatched performance and
carrier-class quality with the following features:
•
Superior spectral efficiency at 5, 10, 20MHz and 40MHz channels in
the 5.3, 5.4 and 5.8 GHz spectrum bands.
•
High Ethernet capacity (up to 270Mbps at 40MHz channel bandwidth.)
•
Combo frequency products for maximum flexibility
•
Advanced air-interface based on MIMO, built-in diversity and OFDM
technologies
•
Superior range performance
•
Simple installation and management
•
High Tx power
The RADWIN 1000/2000 radio series supports the 2.4, 4.9, 5.3, 5.4 and 5.8
GHz spectrum bands, and complies with international standards and regulations (FCC, IC Canada). The 5.8 GHz spectrum band complies with FCC rule
47 CFR Part 15 subparts C and E.
The RADWIN 5000 radio series supports 4.9, 5.3, 5.4 and 5.8 GHz spectrum
bands, and complies with international standards and regulations (FCC, IC
Canada). The 5.8 GHz spectrum band complies with FCC rule 47 CFR Part
15 subparts C and E.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-1
Key Applications
Chapter 1
The model RADWIN 1000 RW-1020-0150 / RADWIN 2000 RW-2020-0150
supports the 2.4GHz band and complies with FCC and IC standards.
The RADWIN 1000 3GHz Band / RADWIN 2000 3GHz Band / RADWIN 5000
3GHz Band support the 3.5 and 3.65 GHz spectrum bands and comply with
FCC and IC standards.
Key Applications
WiMAX and IP Backhaul
The RADWIN 1000/2000/5000 radio series offers WiMAX operators and ISPs
a unique, highly scalable and cost-effective backhaul solution. Designed to
suit a wide range of topologies, RADWIN 1000/2000/5000 is easy to install
and maintain, enabling operators to quickly and efficiently expand their networks and introduce new services to a growing subscriber base.
Figure 1-1: Typical Wimax and IP Backhaul application
Broadband Access
With RADWIN 1000/2000/5000, service providers can quickly and efficiently
expand their networks, and provide high-capacity services that meet the
increasing demand for high-quality, high-speed broadband.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-2
Private Networks
Chapter 1
Figure 1-2: Typical Broadband Access application
Private Networks
RADWIN 1000/2000/5000 is the ultimate solution for private networks such
as enterprises, education, government and utility organizations that wish to
own and manage their own networks and eliminate the costly recurring
charges from service providers.
RADWIN 1000/2000/5000's cost-effective solution enables a variety of organizations to connect geographically dispersed sites at ranges of up to 80km
(50 miles).
Figure 1-3: Private Network
Key Features of RADWIN 1000/2000/5000
Some of the outstanding features of the RADWIN 1000/2000/5000 radio
series are as follows:
High Capacity
The RADWIN 1000/2000 system provides a high-capacity link of up
to 270Mbps at 40MHz channel bandwidth.
Superior Spectral Efficiency
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-3
Key Features of RADWIN 1000/2000/5000
Chapter 1
Built on advanced MIMO and OFDM technologies, the RADWIN
1000/2000 system provides a high-capacity link at channel bandwidth of 40MHz. This channel bandwidth supports high robustness
of the air interface under interference and harsh conditions. In countries where applicable, narrow channel bandwidth reduces the cost
of the spectrum license.
Advanced Air Interface
The RADWIN 1000/2000/5000 system provides an advanced airinterface based on MIMO, built-in diversity and OFDM technologies,
resulting in an exceptionally robust air interface.
Using the following technologies, the RADWIN 1000/2000/5000 air
interface is designed to ensure nonstop, high quality transmission,
even under interference and harsh conditions:
•
Automatic Adaptive Rate (AAR) is a mechanism that dynamically adapts the air interface rate by changing both the signal
modulation and coding.
•
Automatic Channel Selection (ACS) chooses the best channel by
monitoring the available radio channels and dynamically selecting a channel which is best suited for transmission at any given
time.
•
Automatic Repeat Request (ARQ) is a mechanism for error control during data transmission. When the receiver detects an
error in the received information, it automatically requests the
transmitter to resend the information. This process is repeated
until the transmission is error free or the error continues
beyond a predetermined number of maximum transmissions.
RADWIN 1000/2000/5000's ARQ mechanism is optimized for
time-critical traffic.
•
Forward Error Correction (FEC) with very low overhead and
algorithms specifically designed for the varying conditions of
license-exempt frequency bands, ensuring fast, robust and
error-free communications.
High transmission (Tx) power of 29.95dBm
The RADWIN 1000/2000/5000 system supports high Tx power, compliant with radio regulations. High Tx power increases the system's
availability and range, and enables the high performance with
smaller antennas, thus reducing the total cost of the solution (lower
CAPEX), installation and tower rent costs (lower OPEX).
Superior range performance
The RADWIN 1000/2000/5000 system supports high capacity at
superior ranges. The Link Budget Calculator (appendix D) is used to
determine the capacity and range according to the choice of product, antenna, type of service and environmental conditions.
Simple installation and management
RADWIN 1000/2000/5000 systems are extremely simple to install
and maintain. They are typically up and running in less than an hour.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-4
RADWIN 1000/2000/5000 Link
Chapter 1
The RADWIN Manager application has full local and remote management capabilities. The user-friendly SNMP based management tool
provides full end-to-end configuration, event logging, and performance monitoring capabilities.
Enhanced Security
The security features of RADWIN 1000/2000/5000 include:
•
RADWIN 1000/2000/5000's AES 128-bit integrated advanced
encryption support provides enhanced air interface security for
carriers and private networks. It ensures user data protection
with one of the most sophisticated commercially available combined encryption and authentication techniques, CCM/AES. This
technique combines message authentication (preventing antispoofing and replay protection) with commercial encryption,
and complies with the IEEE 802.11i (phase iii) security recommendations.
CCM/AES uses a symmetric 128-bit encryption key (EK), and a
nonce, and provides both message encryption and authenticating signature. The nonce mechanism enables the receiver to
remember already received genuine messages and reject all
replayed messages.
•
Initial encryption and authentication is based on a user-defined
master key (Link Password). While standard Wireless LAN
encrypts only the Ethernet Payload, the AES encrypts both the
source and destination MAC addresses.
•
In addition to normal login access, Read or Write Community
access is available at login
RADWIN 1000/2000/5000 Link
The RADWIN 1000/2000 point-to-point solution is a wireless communication
link. RADWIN 5000 is a point-to-multipoint topology solution. Typically each
side of the link is comprised of an Outdoor Unit (ODU) and antenna and an
Indoor Unit (IDU) or PoE device as shown in figure 1-4 below.
The link is managed by the SNMP-based RADWIN Manager application.
The IDU and the ODU are connected by a CAT5e cable that carries the service traffic and power.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-5
The Radio Outdoor Unit (ODU)
Chapter 1
Figure 1-4: Example of Link Architecture - System Components
The Radio Outdoor Unit (ODU)
The ODU is the radio transceiver of the RADWIN 1000/2000/5000 system.
It supports two radios for MIMO operation. It is available with an integrated
antenna (Integrated Antenna ODU) or with connectors for an external
antenna (Connectorized ODU).
The ODU may be mounted on a pole or a wall, and connects to the IDU or
PoE device using a CAT5e cable.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-6
The Radio Outdoor Unit (ODU)
Chapter 1
The ODU comes in two form factors as shown in figure 1-5 below:
a. Connectorized ODU - Front
b. Connectorized ODU - Rear
c. Integrated Antenna ODU Front
d. Integrated Antenna ODU Rear
Figure 1-5: ODU Form Factors
•
Integrated Antenna ODU
This ODU has an integrated 370mm (1.2ft) flat panel antenna, with
a gain of 23dBi. The ODU contains both the radio and the antenna
as a single unit housed in a weatherproof case.
•
Connectorized ODU
This ODU has 2x N-type connectors for connecting an external
antenna.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-7
The Indoor Units (IDU)
Chapter 1
The ODU products available in release 2.5.30p3 are shown below:
Table 1-1: Available ODU Products - Release 2.5.30p3
Description
Part Number
Form Factor
RW-2050-0150
RW-5550-0150
Integrated antenna
RW-2050-0250
Connectorized for external antenna (2x N-type)
RW-2020-0150
RW-1020-0150
Frequency Bands and Regulations
FCC/IC5.725
FCC/IC5.250
FCC/IC5.470
FCC/IC4.940
FCC/IC2.400
–
–
–
–
–
5.850 GHz
5.350 GHz
5.725 GHz
4.990 GHz
2.4835 GHz
FCC/IC2.400 – 2.4835GHz
RW-1030 3 GHz BAND
RW-2030 3 GHz BAND
RW-2030 3 GHz BAND
RW-5200-0250
RW-5550-0250
Integrated and connectorized antenna (2x N-Type)
Connectorized for external antenna (2 x N-type)
FCC/IC3.650 – 3.700GHz
IC3.475 – 3.650GHz
FCC/IC5.725 – 5.850 GHz
FCC/IC5.250 – 5.350 GHz
FCC/IC5.470 – 5.725 GHz
FCC/IC 5.725 – 5.825 GHz
FCC/IC4.940 – 4.990 GHz
The only available external antenna is, single bipolar.
For further information, see page 4-20, Installing the Link: Step 4, Tx
Power and Antenna Settings.
The Indoor Units (IDU)
IDU-C
The IDU-C has the service ports and provides aggregation of these services
towards the ODU that transports them over the air. The IDU-C also provides
power to the ODU.
The IDU-C is a carrier-class 19 inch, 1U unit, providing two Ethernet ports,
dry contact alarms and indication LEDs. It has two DC power feed connectors. An AC to DC converter is available for powering the IDU-C from an AC
source. The IDU-C is designed to be rack mounted.
One IDU-C product is available in release 2.5.30p3:
Table 1-2: Release 2.1 IDU-C Products
Part Number
7200-2000
Ethernet
ports
Power
Dual DC feed
-20 to -60VDC
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
Form
factor
19" 1U
1-8
Power Over Ethernet (PoE) Devices
Chapter 1
Figure 1-6: IDU-C Front Panel
IDU-E
The IDU-E is a carrier grade, compact, half 19 inch wide, 1U plastic unit,
providing up to two Ethernet ports and up to two E1/T1 interfaces. It offers
Layer 2 support for Ethernet service and HSS support for collocated links. It
is a low cost unit intended for both Access applications and Enterprise use.
Figure 1-7: IDU-E - front view
The IDU-E rear panel (right to left) has a 25 pin Dry Contact Alarms port.
the two (or no) trunk ports, two LAN ports, an ODU port and finally a 3 pin
DC power plug identical to that used on the IDU-C.
Figure 1-8: IDU-E: Rear panel
Power Over Ethernet (PoE) Devices
The PoE device provides Ethernet service only, with power for the ODU. The
PoE device is extremely compact, having only two Ethernet ports and a
standard 3 pin male AC power socket.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-9
Antennas
Chapter 1
Figure 1-9: PoE device - showing the radio Ethernet port
Antennas
An antenna is the radiating and receiving element from which the radio signal, in the form of RF power, is radiated to its surroundings and vice versa.
The antenna gain and transmitting power may be limited by country regulations.
The RADWIN 1000/2000/5000 may be operated with an integrated antenna
that is part of the ODU unit, or with external antennas connected to the
ODU via N-type connectors. All cables and connections must be connected
correctly to reduce RF losses. The required antenna impedance is 50Ω.
The Integrated Antenna ODU is provided with 370 mm (1.2ft) flat panel
antenna. The radio and the antenna are housed in a weatherproof case as a
single unit.
Figure 1-10: ODU with integrated Flat Panel antenna
External antennas are available for the RADWIN 1000/2000/5000 radios,
varying in operating frequencies, form factor, size and gain, dual or single
polarization.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-10
Antennas
Chapter 1
The RADWIN 1000/2000 operating in frequency bands 5.3, 5.4, 5.8 GHz can
utilize external antennas with RF feeder cables that produce 6 dBi mi-nimal
assembly gain.
The RADWIN 1000 3GHz Band / RADWIN 2000 3GHz Band / RADWIN 5000
3GHz Band operating in the 3.5 and 3.65 GHz can utilize external antennas
with RF feeder cables that produce 13.5 dBi minimal assembly gain.
Flat Panel Antennas
The Flat Panel antenna shown in figure 1-11 below has an integrated or
external configuration:
Integrated or External
1.2ft Flat Panel Dual Polarization
Frequency
4.9
2.4
2.3
3.3
–
–
–
–
6.0
2.7
2.7
3.8
GHz
GHz (Ext)
GHz (Int)
GHz (Int/Ext)
Gain
External
21 dBi at 4.9 – 5.0 GHz
22 dBi at 5.0 – 5.15 GHz
23 dBi at 5.15 – 6.0 GHz
20 dBi at 2.4 – 2.7 GHz
22 dBi at 3.3 – 3.8 GHz
14 dBi at 4.9 – 5.95 GHz
14.5 dBi at 4.9 – 4.95 GHz
15 dBi at 4.95 – 5.15 GHz
15.5 dBi at 5.15 – 5.47 GHz
16.5 dBi at 5.47 – 6.0 GHz
13.5 dBi at 6.0 – 6.06 GHz
Integrated
21 dBi at 4.9 – 5.0 GHz
22 dBi at 5.0 – 5.15 GHz
23.5 dBi at 5.15 – 5.725 GHz
24 dBi at 5.725 – 6.0 GHz
16.2 dBi at 2.3 – 2.4 GHz
17.5 dBi at 2.4 – 2.7 GHz
21 dBi at 3.3 – 3.8 GHz
Size
1.2 x 1.2 ft / 371x371 mm
Figure 1-11: Flat Panel Antenna
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-11
RADWIN Manager
Chapter 1
Parabolic Dish Antennas
External
2ft Dish Dual Polarization
Frequency
5.150 - 5.875 GHz
4.900 – 5.850 GHz
3.300 – 3.800 GHz
Gain
28 dBi
25 dBi (3.5/3.65GHz)
Diameter
2 ft / 620 mm
Beam Width
H,V: 5.6°
Figure 1-12: External Antennas - Parabolic Dish
See the RADWIN products catalog for RADWIN offering of external antennas. External antennas are also available from authorized antenna vendors.
RADWIN Manager
The RADWIN Manager is an SNMP-based management application which
manages a complete link over a single IP address. It can also manage each
side of the link separately.
The RADWIN Manager application facilitates installation and configuration
of the link between the ODU units. The intuitive, easy-to-use RADWIN Manager has a graphical Microsoft Windows interface, and can be run locally
and remotely.
The RADWIN Manager provides:
•
Installation Wizard
•
On-line monitoring of air interface quality allowing the administrator
to monitor the service and status of each link
•
On-line monitoring of equipment alarms and QoS
•
Local and remote loopback testing
•
Configuration settings
•
On-line user manual and help files
•
Link Budget Calculator for calculating the expected performance of
the RADWIN 1000/2000/5000 wireless link and the possible service
configurations for a specific link range.
The RADWIN Manager can easily be integrated with any NMS system.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-12
Accessories
Chapter 1
Figure 1-13: RADWIN Manager screen
Accessories
RADWIN provides a variety of accessories to support the RADWIN 1000/
2000/5000 system:
•
PoE devices
•
AC Power Adaptor
•
External Lightning Protection Unit
•
Cables to connect the various system elements
Documentation set supplied with RADWIN 1000/2000/
5000
The technical documentation supplied with a RADWIN 1000/2000/5000
includes the following items:
•
A Quick Start Guide for experienced installers
•
A full User Manual - the document which you are reading
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-13
How to Use this Manual
Chapter 1
How to Use this Manual
This User Manual is divided into functionally distinct chapters reflecting the
activities required to set up a RADWIN 1000/2000/5000. The division is
shown in the following table:
Chapter/
Appendix
Subject
Audience
Site Preparation
Site survey team
Hardware Installation
Field technician
Link Installation:
The RADWIN Man- Installation technician
ager
Configuring the
Link
Installation technician, System manager
Site Configuration
Installation technician, System manager
Monitoring and
Diagnostics
Installation technician, System manager
Technical Specifications
Installation technician, System manager
Wiring Specifications
Installation technician
Pole and Wall
Installation
Installation technician
Link Budget Calculator
Installation technician
Lightning Protection and Grounding Guidelines
Field technician
MIB Reference
System manager
External Alarms
Specification
Installation technician, System manager,
Field technician
Combo Configuration Tool
Installation technician
A Little Terminology
In the field, a link typically has a local or headquarters site as for example in
figure 1-2 above. Here the service provider is the local or headquarters
site. The service recipient is the remote site.
Where the link is completely internal to a corporation, the choice of the local
and remote is just a matter of convenience.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-14
A Little Terminology
Chapter 1
A link then, consists of two sites.
In Broadband Wireless terminology, the local and remote sites are sometimes referred to as “near” and “far”, “HQ” and “remote” and so on.
The site which is closer to the network core (often the local site) will be
referred to as site A, and the opposite side of the link, usually closer to the
end user, as site B.
This choice is application-neutral and will be used throughout the manual
both to describe the sites and their names as in the examples.
The link is configured and managed using a PC, the managing computer
connected to site A. (The precise requirements for the managing computer
are set out in chapter 3, Hardware Installation).
RADWIN 1000/2000/5000 supports three connection methods for the managing computer:
•
Local - a direct peer to peer connection between the Ethernet ports
on the managing computer and the IDU or PoE device. Local connection is always read-write.
•
Network - the managing computer and the site A IDU or PoE
device belong to a LAN and communicate through a router or hub
•
Over-the-air - the managing computer connects to site B via the
air interface
The managing computer may be connected to the link through an IDU or a
PoE device. In what follows, where ever we refer to an IDU it includes PoE
devices unless stated otherwise. Typically, if we need to refer to an IDU as
such, we will use a model name such as IDU-C.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-15
Conventions Used in this Manual
Chapter 1
Conventions Used in this Manual
Notifications
Notifications consist of Notes, Cautions and Warnings.
The purpose of a Note is to
Note
•
Draw your attention to something that may not be obvious or counter-intuitive
•
Emphasize a special feature or peculiarity of the RADWIN 1000/2000/
5000
•
Offer an external reference for additional information
•
Add a caveat that would not qualify as a full Caution or Warning (see
below)
•
Provide additional background to what follows
•
Offer a recommendation
•
Highlight an indication of something to watch out for
•
Advise you if an action has “side effects” i.e. it may disturb something
else that would be best left undisturbed
•
Remind you of something that should be kept in mind
A Caution is a notification of risk of damage to equipment or of service
degradation
Caution
A Warning is a notification of risk of danger to persons operating near the
equipment
Warning
Typographical conventions
General
Where a term is defined or introduced for the first time, it is shown in Boldface. You will have noticed this usage in the Terminology section above.
Software
The RADWIN Manager is a Microsoft Windows application following the user
interface conventions of familiar Microsoft Windows programs.
We would describe the chain of menu commands indicated in the following
screen shot, like this:
Tools|Active Alarms|1 A
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-16
Windows Terminology
Chapter 1
using Boldface for the menu labels and vertical bars to separate them.
Similarly, mouse click items will be referred to like this:
“Click Next to continue.”
(A mouse click always uses the left mouse button unless stated otherwise.)
Windows Terminology
Look at figure 1-13 above. The main application display which you see
consists of a frame-window with a menu bar, system icons and content. It
will be referred to as a window, the main window or the Manager window depending on context.
The top line of icons is the tool bar, and provides part of the menu bar
functionality with a mouse click.
At the bottom of the window is the status bar, a line of icons and text
boxes.
The central part of the main window consists of several panes: On the
right, there are Radio Interference, Ethernet Service and the Frequency
panes. The left hand pane (with the blue background) is split into three
sub-panes.
If you click Site A or Site B in the tool bar, you will be offered another window, which in turn displays on of several panels depending on which function you choose.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-17
Windows Terminology
Chapter 1
Figure 1-14: Site Configuration window with open Management panel
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
1-18
Chapter 2
Site Preparation
Planning the Link Site
Overview
Link site planning consists of a set of surveys, which must be carried out
before any equipment is brought to the site. If for some reason, the outcome of any of these surveys is negative, site re-location will need to be
considered.
A Site Survey consists of three stages:
1. Preliminary survey - The proposed link is analyzed in the office using a
topographic map.
2. Physical survey - The locations of the RADWIN 1000/2000/5000 indoor
and outdoor equipment are determined on-site.
3. Radio Frequency (RF) survey - It is recommended that the installation
area be scanned with a spectrum analyzer, to identify RF interference so
as to determine a clear channel for RADWIN 1000/2000/5000 installation
(on-site).
The Site Survey
Introduction
RADWIN 1000/2000/5000 wireless links must be planned before installation. The designated installation site must be appraised to determine that
the wireless system is able to operate efficiently and provide connectivity
without signal degradation.
RADWIN 1000/2000/5000 offers a wide operating frequency range. A free
frequency channel must be determined within the operating range, for optimum performance.
Recommended Equipment
Stage 1: Preliminary Survey
• Topological map of the area
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
2-1
Stage 1: Preliminary Survey
•
Urban map of the area
•
Compass
Chapter 2
Stage 2: Physical Survey
• 100 meter tape measure
•
Ohmmeter, to check ground connection
•
Binoculars
•
Map
•
Digital camera
•
Paper, pencil, and a clipboard
•
GPS device (optional)
•
Compass (optional)
Stage 3: RF Survey
• Spectrum Analyzer with Max Hold function and screen capture facility that can store multiple images, for documentation purposes
•
RF accessories (connectors and cables)
•
Communication devices (for example, cellular phones, or a set of
walkie-talkies)
Stage 1: Preliminary Survey
A preliminary survey is necessary before visiting potential installation sites.
As much detail as possible should be obtained about the two designated
ODU installation sites and the area between them.
 To perform a preliminary survey:
1. Mark the two designated installation sites on a topographic map of the
area.
2. Measure the distance between the sites; check that it is within the specified range of the RADWIN 1000/2000/5000.
3. On the urban map, check for developed areas situated between the two
installation sites. Pay attention to these areas when performing the physical site survey; there may be tall buildings, RF towers, or transmitters,
which could cause interference to the link.
4. Check the area between the two sites for obstructions such as:
•
High ground - hills or mountains
•
Lakes or large bodies of water. Water has a reflection effect on RF
signals like a building. This type of reflection causes the received
amplitude to be reduced. As a rule of thumb, the presence of a large
body of water between the link sites may double the required
antenna height.
5. Determine and record the compass bearings between both ODUs, relative to north.
6. If there are obstructions between the two sites, calculate the Fresnel
Zone (see appendix D for details).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
2-2
Stage 2: Physical Survey
Chapter 2
7. If the site chosen does not meet requirements, consider alternative sites.
8. Use the Link Budget Calculator (on the CD supplied with the RADWIN
1000/2000/5000 or using the RADWIN Manager) to determine the
expected performance.
Stage 2: Physical Survey
The physical site survey reviews the environment of the proposed RADWIN
1000/2000/5000 installation location, to ensure that the link sites are suitable for the wireless network. The results of the physical site survey should
be recorded.
It is advisable to go on a clear day, so you can more easily see any
obstructions between the two sites.
Note
 To perform a physical survey:
1. From the compass readings taken in the preliminary survey, find the azimuth (horizontal position) that the ODU should face towards the second
ODU.
2. Using binoculars, locate any obstructions such as tall trees, high buildings, hills or mountains. Look for other RF towers between the two sites.
Mark the locations of the obstructions on the map.
3. Determine the location for the ODU (having regard for existing rooftop
installations and tower space). It should be above any obstructions, considering the Fresnel zone (see appendix D).
4. If you need to install the ODU on a tower, make sure that the tower is far
away from overhead electric power lines.
5. Determine a location for the indoor equipment; it should be as close as
possible to the ODU. At an existing site, there is probably an equipment
room with cable-routing channels.
The IDU - ODU cable length limit is 100m, in accordance with IEEE 10/
100BaseT standards.
Note
6. Measure and record the path length of the cable from the ODU position
to the indoor equipment room.
7. Determine the ground and lightning connection points of the installation.
The RADWIN 1000/2000/5000 ODU and IDU must both be grounded.
8. Using the Ohmmeter, measure and record the resistance of the required
installation to the grounding point. The resistance must be less than 1O
ohm.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
2-3
Additional Outdoor Site Requirements
Chapter 2
9. Review the results of the physical site survey. Decide if the site is suitable
for the RADWIN 1000/2000/5000 wireless network installation.
•
If the site is suitable, continue with stage 3, the RF survey
•
If the site is not suitable, survey another site
Additional Outdoor Site Requirements
The ambient outdoor operating temperature should be -35 to 60C (-31 to
140F).
Additional Indoor Site Requirements
The following requirements guarantee proper operation of the system:
•
For IDU-C units, allow at least 90 cm (36 “) of front clearance for
operating and maintenance accessibility. Allow at least 10 cm (4 “)
clearance at the rear of the unit for signal lines and interface cables
•
The ambient operating temperature should be 0 to 50°C (32 to 122
°F) at a humidity of up to 90%, non condensing
Stage 3: RF Survey
The RF survey examines the wireless environment of the RADWIN 1000/
2000/5000 installation site, to determine whether there are available channels within the RADWIN 1000/2000/5000 operating frequency band. An RF
survey is performed using a spectrum analyzer.
It is advisable to familiarize yourself with the spectrum analyzer before
going out on site, specifically the Max Hold and Marker functions.
You should perform the RF survey at both proposed link sites.
The survey should be carried out during a busy time of day, to best judge
the worst-case radio interference. Allow 2-4 hours duration for a good RF
survey.
Note
It is possible to install the RADWIN 1000/2000/5000 link and use the
RADWIN Manager to find a clear channel. Each frequency channel can be
evaluated in turn. Achievement of a clear channel is indicated by the Quality
bar on the Channel Setting window (see figure 4-13) becoming green.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
2-4
Chapter 3
Hardware Installation
This chapter sets out the requirements and procedures for the hardware
installation and alignment of a RADWIN 1000/2000/5000 link in accordance
with the prior planning as set out in chapter 2. It is intended to guide qualified field technicians.
Warning
Outdoor units and antennas should be installed ONLY by experienced
installation professionals who are familiar with local building and safety
codes and, wherever applicable, are licensed by the appropriate
government regulatory authorities. Failure to do so may expose the end
user or the service provider to legal and financial liabilities. RADWIN and its
resellers or distributors are not liable for injury, damage or violation of
regulations associated with the installation of outdoor units or antennas.
Safety Practices
Preventing overexposure to RF energy
To protect against overexposure to RF energy, install the ODUs so as to provide and maintain minimal separation distances from all persons.
When the system is operational, avoid standing directly in front of the
antenna. Strong RF fields are present when the transmitter is on. The ODU
must not be deployed in a location where it is possible for people to stand
or walk inadvertently in front of the antenna.
Grounding
All RADWIN products should be grounded during operation. In addition:
•
The ODU should be earthed by a wire with diameter of at least
12AWG.
The RADWIN 1000/2000/5000 ODU must be properly grounded to
protect against lightning. It is the user's responsibility to install the
equipment in accordance with Section 810 of the National Electric
Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code. These codes describe correct installation procedures for
grounding the outdoor unit, mast, lead-in wire and discharge unit. It
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-1
Protection against Lightning
Chapter 3
also lays down the size of grounding conductors and connection
requirements for grounding electrodes.
The RADWIN 1000/2000/5000 ODU must be grounded to a Protective Earth as described in appendix E and in accordance with the
Local Electrical Regulations.
•
The earth lug on the IDU-C and IDU-E should be connected to the
protective earth at all times, by a wire with a diameter of 18 AWG
or wider. Rack-mounted equipment should be mounted only in
earthed racks and cabinets.
Further, you should •
Always make the ground connection first and disconnect it last
•
Never connect telecommunication cables to ungrounded equipment
•
Ensure that all other cables are disconnected before disconnecting
the ground
More detailed guidelines are supplied in appendix E.
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user
requirements. All of RADWIN outdoor units are designed with surge limiting
circuits to minimize the risk of damage due to lightning strikes. RADWIN
recommends the use of additional surge arrestor devices to protect the
equipment from nearby lightning strikes.
See appendix E for detailed installation instructions of lightning protection
devices.
General
•
It is recommended that installation of the outdoor unit be contracted
to a professional installer.
•
Before working on equipment connected to power lines or telecommunication lines, you should remove jewelry or any other metallic
object that may come into contact with energized parts.
•
Use extreme care when installing antennas near power lines.
•
Use extreme care when working at heights.
•
When using an AC power source for RADWIN 1000/2000/5000
always use the AC power adapter supplied by RADWIN.
•
Use the right tools. In addition to standard tools required for any
kind of ODU or antenna installation, RADWIN 1000/2000/5000
requires additional specific tools detailed on page 3-5 below.
Package Contents
The RADWIN 1000/2000/5000 packages include the following items:
ODU Package Contents
The ODU package contains:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-2
ODU Package Contents
Chapter 3
•
One ODU - see figure 3-2 below for front and rear view
•
An ODU mounting kit - see figure 3-1 below
•
A CD containing •
the RADWIN Manager
•
Quick Start Guide
•
User Manual
•
Link Budget Calculator
•
Label showing the MAC address and the alternative Community
string. The label is self-adhesive. You should keep this label safe
•
Cable glands (to be used with the ODU-IDU cable)
Figure 3-1: ODU Mounting kit
ODU - Front View
ODU - Rear View
Figure 3-2: Connectorized ODU - Front and rear views
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-3
IDU Package Contents
ODU - Front View
Chapter 3
ODU - Rear View
Figure 3-3: Integrated ODU - Front and rear views
IDU Package Contents
The IDU package contains:
•
IDU-C - see figure 3-4 below.
•
19” rack mounting kit - see figure 3-5 below
•
Two DC power plugs for power cables - see figure 3-5 below
Figure 3-4: IDU-C Package contents - the IDU-C
Figure3-5:IDU-CPackagecontents-themountingkitandDCpowerplugs
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-4
External Antenna Package Contents
Chapter 3
External Antenna Package Contents
•
Antenna
•
RF cable 1m (3’) long; two cables supplied with bipolar antennas,
single cable supplied with monopolar antennas
•
Mounting kit
Additional Tools and Materials Required
The following is a list of the equipment and materials required to install
RADWIN 1000/2000/5000 hardware.
Tools and Materials
•
Crimping tool for RJ-45 (if the ODU-IDU cable is without connectors)
•
Spanner/wrench 13 mm (½”)
•
Drill (for wall mounting only)
•
Cable ties
•
Sealing material
Cables and connectors
•
ODU grounding cable 12AWG
•
IDU grounding cable 18AWG
•
ODU-IDU cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG)
Hardware Installation Sequence
The following steps are required to install the RADWIN 1000/2000/5000
system:
1. Mounting the ODUs, page page 3-6.
2. Mounting the external antennas (if used), page page 3-7.
3. Mounting the Lightning Protection devices (if used), page page 3-7.
4. Outdoor connections, page page 3-8.
5. Mounting the IDUs, page page 3-8.
6. Indoor connections, page page 3-12.
7. Aligning the ODUs/antennas, page page 3-13.
See figure 3-6 below, which illustrates a typical installation of RADWIN
1000/2000/5000 with an external antenna.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-5
Outdoor installation
Chapter 3
Figure 3-6: Typical Installation Diagram (with external antenna)
The installation steps are detailed in the following sections.
Outdoor installation
Mounting the ODU
The ODU can be mounted on a pole or a wall. In both installations, the supplied mounting kit is used to secure the ODU.
A mast-sited ODU typically uses a pole attached to the mast.
Note
A RADWIN 1000/2000/5000 link operates in pairs of two ODUs with the
same configuration. Both ODUs must be installed, and the antennas aligned
for maximum throughput.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-6
Mounting external antennas
Warning
Chapter 3
Prior to connecting cables to the ODU, the protective earth terminal (screw)
of the ODU must be connected to an external protective ground conductor
or to a grounded pole.
•
Only a qualified person using the proper safety equipment should
climb the antenna mast
•
Only qualified professional personnel should install or dismantle
ODUs and masts
 To mount the ODU on a pole or a wall:
1. Ensure that the ODU is properly grounded.
2. Mount the ODU onto the pole or wall. Ensure that the unit is oriented so
that the cable connectors are at the bottom. (If they are on top,
water may penetrate into the unit causing damage.)
3. Refer to Appendix C, Pole and Wall Installation for detailed ODU
mounting kit contents and schematics.
Do not tighten the ODU to its mounting brackets until the alignment
process of the antenna is complete.
Note
Ensure that there are no direct obstructions in front of the ODU or
interference from man-made obstacles.
Mounting external antennas
If you are using ODU with an integrated antenna, skip to Mounting the
Lightning Protection Devices below.
The supplied mounting kit is used to mount the antenna onto a pole. The
antennas must be aligned for maximum throughput.
Do not stand in front of a live antenna.
Warning
 To mount an external antenna:
1. To mount an external antenna ensure that the antenna is properly
grounded and then mount the antenna onto the pole. Refer to Appendix C, Pole and Wall Installation for detailed antenna mounting
instructions.
2. Follow the mounting instructions supplied with the antenna.
Mounting the Lightning Protection Devices
The use of lightning protection is dependent on regulatory and end user
requirements. The RADWIN 1000/2000/5000 ODU is designed with surge
limiting circuits to minimize the risk of damage due to lightning strikes.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-7
Outdoor Connections
Chapter 3
RADWIN recommends the use of additional surge arrestor devices to protect the equipment from nearby lightning strikes.
Refer to appendix E for detailed installation instructions of lightning protection devices.
Outdoor Connections
 To complete the outdoor connections:
1. Connect the ground cable to the ODU chassis as marked on the ODU.
2. Connect the antenna cable(s) to the ODU.
3. Connect the lightning protection device to the ODU (see appendix E).
4. Attach the ODU-IDU cable to the ODU RJ-45 connector (see appendix B
for the connector pin-out)
5. Screw in the cable glands to ensure hermetic sealing of the ODU.
6. Secure the cables to the pole, mast or brackets using UV-rated cable ties.
Indoor Installation
IDU-E Installation
The IDU-E can be wall mounted, placed on a desktop or take up one half of
a 1U rack slot. The unit should be grounded, cabled to the ODU and connected to power using the supplied AC/DC adapter.
Figure 3-7: New style IDU-E: Rear panel
Mounting the IDU-C
The RADWIN 1000/2000/5000 IDUs are all rack mounted, as shown in
figure 1-6. A front panel keyed schematic of a rack mounted IDU-C is
shown in figure 3-8 below.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-8
Mounting the IDU-C
Chapter 3
Figure 3-8: IDU-C front panel
In figure 3-9 we display a perspective view of the IDU-C:
Figure 3-9: IDU-C - A perspective view
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-9
Mounting the IDU-C
Chapter 3
Further description of the keyed items in figure 3-8 is shown in table 3-1
below:
Table 3-1: Components of an IDU-C front panel
Key
Label
Remarks
Indicator LEDs
See figure 3-10.
ODU Port
RJ-45 connector, see table B-1.
2 LAN Ports
Ethernet, RJ-45 connector, see table B-2
SFP Port
The IDU-C is SFP ready.
Alarm Ports
Standard DB25 female connector, see
table B-3.
Label indent
Place for adhesive identification labels
Primary 3 pin Power
Connector
Standard 3 pins in line power connector,
see table B-4.
Secondary 3 pin
Power Connector
Standard 3 pins in line power connector,
see table B-4.
Grounding Lug
Use the lug supplied
Rack mounting
holes
Detachable Rack
mounting brackets
The Indicator LEDs (Item A in table 3-1 above) are shown in more detail in
figure 3-10 below:
Figure 3-10: IDU-C LEDs
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-10
Connecting power to the IDU
Chapter 3
The purpose of the LEDs is shown in table 3-2 below:
Table 3-2: IDU-C Front Panel LEDs
Name
Color
Function
IDU
Green
IDU operational
Green
During power-up only
Red
Failure
Green
ODU-to-IDU communication link is operating
Red
ODU-to-IDU communication link is disrupted
Green
Wireless link is synchronized
Orange
During installation mode only
Red
Wireless link lost synchronization
ODU
AIR I/F
SVC
Off
HSS
Off
 To mount an IDU (using figure 3-8 above):
1. If the rack already holds other equipment, ensure that it is properly
grounded.
Do not proceed with installation into a “live” rack unless it is properly
grounded.
Warning
2. Attach the rack mounting brackets (K) to the IDU.
3. Bolt the IDU into an empty slot in the rack, ensuring that it sits securely.
4. Ground the IDU to the rack using grounding lug I. The IDU should be left
permanently grounded.
Instead of using the rack mounting brackets, the IDU may be rail mounted
using the four screw holes on each of its sides.
Note
Connecting power to the IDU
The IDU-C has redundant power connection circuits (items G and H in
figure 3-8 above). An enlarged schematic of the power connectors is
shown in below:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-11
Connecting the ODU to the IDU
Chapter 3
Figure 3-11: DU-C ower connectors
The connectors are 3 pin in line female, with polarities (left to right) minus,
ground, plus. To avoid damage to the IDU, always use an AC/DC adapter
supplied by RADWIN.
Ensure that the IDUs at both sites are powered up.
Connecting the ODU to the IDU
The ODU-IDU cable conducts all the user traffic between the IDU and the
ODU, and also provides power to the ODU. The maximum length of the
ODU-IDU cable is 100m (328 ') in accordance with 10/100BaseT standards.
The ODU-IDU cable is supplied pre-assembled with RJ-45 connectors, at the
length specified when ordering, or as a cable drum with spare connectors. If
the ODU-IDU cable was not ordered, use an outdoor class, CAT-5e 24AWG
shielded cable. See appendix B for Wiring Specifications.
To connect the ODU to the IDU, route the cable from the ODU to the IDU,
secure the cable along its path and connect the cable to the ODU RJ-45
connector on the IDU (see item B in figure 3-8 above).
Installing a Link using PoE Devices
The PoE device is a very simple unit having a power input connector and
two Ethernet ports. It is AC powered, and has a power LED.
 To prepare a link using PoE devices:
1. To connect the ODU to the PoE device, route the cable from the ODU to
the PoE device, secure the cable along its path and connect the cable to
the P-LAN-OUT RJ-45 connector on the PoE device.
2. Connect it to AC power.
3. Repeat steps 1 to 2 for the second link.
Connecting User Equipment
 To connect user equipment to the IDU:
• Connect user switch/router or any other compatible device to the IDU
panel RJ-45 ports designated LAN (see item C in figure 3-8 above).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-12
Connecting and Aligning ODUs / Antennas
Chapter 3
Refer to appendix B, Wiring Specifications, for connector pinouts.
Do not connect two LAN ports to the same network, or flooding may occur.
Note
 To connect user equipment to the PoE device:
• Connect a user switch, router or any other compatible device to the PoE
device RJ-45 port designated LAN-IN. Refer to appendix B, Wiring
Specifications, for connector pinouts.
Connecting and Aligning ODUs / Antennas
You perform antenna alignment using the ODU's audible tone.
To speed up the installation time, alignment of a RADWIN 1000/2000/5000
system should be performed by two teams simultaneously, at site A and at
site B.
 To align ODUs with integrated antennas or external bipolar antennas:
1. For external bipolar antennas: Using a coax cable with N-Type connectors, connect the vertical polarization connector of the antenna to the
ANT 1 connector of the ODU.
2. For external bipolar antennas: Using a coax cable with N-Type connectors, connect the horizontal polarization connector of the antenna to the
ANT 2 connector of the ODU.
3. Ensure that power is connected to the IDUs at both sites.
4. Ensure normal operation of the IDUs by the LED indications on the front
panel.
Provided that site A detects the signal from site B, the ODU starts beeping 20 seconds after power up, and continues beeping until the ODUs are
aligned, and the installation is complete.
In the following steps, “antenna” refers both to an external antenna and
an integrated antenna.
5. Direct the antenna of site B in the direction of site A. This is simplified if
a previous site survey has been completed and azimuths are known.
When aligning the antennas, do not stand in front of a live antenna.
Warning
6. Make a horizontal sweep of 180 degrees with the site A antenna so that
the strongest signal from site B can be detected.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-13
Connecting and Aligning ODUs / Antennas
Chapter 3
7. Slowly turn the site A antenna back towards the position of site B, listening to the tone until the best signal is reached. See the following figure
for audible signal variations.
Figure 3-12: Beep Sequence for antenna alignment
Note
•
Three beeps and a pause is 'best signal so far'
•
Two beeps and a pause is 'signal quality increased'
•
One beep and pause is 'no change in signal'
•
Long beep and short pause is 'signal quality decreased'
•
One beep and a long pause is 'no air link'
•
Any other signal does not relate to antenna alignment
8. Secure the site A antenna to the pole/wall.
9. Repeat steps 4 to 8 for site B.
 To align two external monopolar antennas:
The ODU buzzer only works on the radio connected to the ANT 1 connector
marked
Note
. You will therefore need to use ANT 1 to align both antennas
in turn. Upon completion of the alignment procedure, you may connect the
two antennas to ANT 1 and ANT 2 connectors.
1. Using a coax cable with N-Type connectors, connect one antenna to the
ANT 1 connector of the ODU.
2. Follow the steps 3 to 7 above to align the antenna connected to the ODU
connector ANT 1 on both sides of the link.
3. On both sides of the link, disconnect the antenna connected to the ODU
connector ANT 1. Connect the other antenna to connector ANT 1 and follow the steps 3 to 7 above to align the second antenna.
4. Secure the antennas to the pole/wall.
5. Restore one of the antennas to ANT 2 on both sides of the link.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
3-14
Chapter 4
Link Installation: The
RADWIN Manager
This chapter explains how to use the RADWIN Manager to install a radio
link.
Installing theRADWIN Manager Application
Minimum System Requirements
The RADWIN Manager application is distributed on a CD. Operating system
specific PC resources required by the application are set out in table 4-1
below:
Table 4-1: PC Requirements for the RADWIN Manager Application
Windows 2000
Windows XP Pro
Windows Vista
Memory
128 MB
512 MB
1 GB
Processor
P III
P IV
P IV Dual Core
Requirements common to all systems are:
•
Hard disk: 1 GB free space
•
Network: 10/100BaseT NIC
•
Graphics: 1024x768 screen resolution with 16 bit color
•
Microsoft Explorer version 5.01 or later
Installing the Software
 To install the RADWIN Manager application:
1. Insert the CD into the CD/DVD drive of your computer.
The CD opening screen appears:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-1
Starting the RADWIN Manager
Chapter 4
2. Choose Install RADWIN Manager and follow the on-screen instructions
of the installation wizard to complete the setup of the RADWIN Manager
application.
If the installation program fails to start, browse to your CD/DVD drive,
chose the setup.exe program and run it.
Any PC running the RADWIN Manager application can be used to configure
a RADWIN 1000/2000/5000 link.
Starting the RADWIN Manager
 To start the RADWIN Manager:
1. Connect the managing computer to one of the two LAN ports as shown
in figure 4-1 below:
Figure 4-1: LAN ports on the front panel of the IDU-C
If you are not using a direct connection as above, ensure that you have
IDU to managing computer connectivity (e.g. through a LAN).
2. Check that you have connectivity to the ODU. You can do this by opening
up a command line session (Start|Run and then type, cmd). At the
command prompt, type
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-2
Starting the RADWIN Manager
Chapter 4
ping 10.0.0.120
You should see something like this:
Figure 4-2: Pinging an uninstalled and unconfigured link
Any other response from ping means that the ODU is not responding.
Check your Ethernet connection and that both the the IDU and ODU are
switched on and then try again. If you do not succeed, seek assistance
from RADWIN Customer Support.
3. Dismiss the command line session.
4. Double-click the RADWIN Manager icon on the desktop, or click
Start|Programs|RADWIN Manager|RADWIN Manager.
The Login dialog box appears.
Figure 4-3: Login Screen
5. Type an IP address for the ODU (if you connect through a network), or
click Local Connection (if you are connected directly to the IDU port).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-3
Starting the RADWIN Manager
Warning
Chapter 4
1. If you log in on Local Connection, but your physical connection is
not local (i.e. anything other than a direct connection between
the managing computer and the IDU), then any configuration
you carry out may affect other links in the network.
2. If you log in via an over-the-air IP address, you will receive a
warning. If you reset the site to which you are connected to
factory settings, you can lock yourself out of the Link.
3. Network login (IP address to the ODU) is recommended.
The default IP address for the ODU is 10.0.0.120. The subnet mask is
255.0.0.0.
Note
The actual IP address is defined during link configuration (see Site
Management: IP Address and VLAN on page 6-4).
6. Enter the password
The default password is admin (see Changing the Log On Password on
page 4-7).
Note
7. If you are a user with Read-Write permission, click Options to enter the
Community options.
Note
RADWIN 1000/2000/5000 is protected with Community passwords. A user
may be defined with read-only permission or with read-write permission
(see page 6-14 for more details).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-4
Login Errors
Chapter 4
Figure 4-4: Login Screen with Community options visible
•
If you are using the system for the first time, leave the default Community passwords, netman for read-write, and public for readonly.
•
If Community values were previously defined, enter them under
Community in the Read-Only or Read-Write boxes.
•
If you are a user with read-only permission, click the Read Only
Mode check box.
The RADWIN Manager main window is displayed (see figure 4-7).
Login Errors
Unsupported Device
Attempting to connect to an unsupported device will result in the following
error message:
Figure 4-5: Unsupported device message
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-5
Incorrect IP Address
Chapter 4
Incorrect IP Address
If the IP address chosen is invalid or the link is unreachable, the following
error message will be displayed:
Figure 4-6: Unreachable device message
In both of the above situations, you will see a warning graphic
side the IP Address field.
along-
Incorrect Password
If you type an incorrect password in the Login screen, you will see a warning graphic
alongside the password field.
Continuing without an IP Address
The RADWIN Manager provides limited “offline” functionality when there is
no accessible IDU/ODU. It is primarily for setting managing computer
related parameters and running the Link Budget Calculator. The offline functionality is shown in table 4-2 below. The table does not show menu items
grayed out.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-6
Changing the Log On Password
Chapter 4
Table 4-2: RADWIN Manager: Offline Functionality
Menu level
Top
+1
Function
+2
Reference
File
Log Off
Return to Log On dialog.
Same as Log Off button
Exit
Exit the RADWIN Manager.
Same as Exit button
Change
Password
Change the Log On password dialog
Tools
page 4-7
page 7-10
Events Log
Clear
Events
Clear local events log
Save to
File
Save events log data to a file
Help
RADWIN
Manager
Help
View online help version of
the User Manual
Link Budget
Calculator
Calculator opened in default
browser
Appendix D
Get
Diagnostics
Information
Obtain system information
page 7-1
About
RADWIN
Manager
RADWIN Manager build
information
Changing the Log On Password
 To change the log on password:
1. From the Tools menu, select Change Password.
The Change Password dialog box appears.
2. Enter the current password, and the new password.
3. Click OK to confirm.
Installing the Link: First steps
At this point the main window of the RADWIN Manager should be displayed:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-7
Installing the Link: First steps
Chapter 4
Figure 4-7: Opening RADWIN Manager window prior to installation
A detailed field by field description of the contents of the RADWIN Manager
main window may be found in chapter 5.
The procedure required to make the link functional has three phases:
1. Link Installation - which we will detail below.
Installation actually gets the link operational by setting the link parameters. It uses a fixed channel at the lowest possible modulation, BPSK at
6.5Mbps and will work under the harsh interference condition.
During the installation procedure, the definition of all parameters is
automatically applied to both sides of the link.
Note
2. Link Configuration - described in chapter 5.
Configuration provides much the same functionality as Installation, but
for a running link. A fallback to Installation mode is provided for situations which cannot be handled without resetting the link, such as
antenna realignment and IDU or ODU replacement.
The Link Installation and Configuration phases are both carried out with
Wizards, which “walk you through” the processes. The Wizards are visually quite similar and will be described in detail below.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-8
Default Settings
Chapter 4
3. Site Configuration - described in chapter 6.
Site specific configuration for each side of the link is available at any time
- under a running link or under the restricted Installation mode.
Site Configuration consists of a set of panels, which may be invoked individually in any order, as needed.
An installed and configured link can be returned to installation mode for reinstallation and configuration from last settings or from factory settings.
Note
•
Reversion to installation mode requires a complete break in the link
service
•
Configuration mode may vary the service throughput and quality, but
without a service break
Default Settings
The default settings of the RADWIN 1000/2000/5000 configuration parameters are listed in table 4-3 below:
Table 4-3: Default Settings
Parameter
Default Value
ODU IP Address
10.0.0.120
Subnet Mask
255.0.0.0
Trap destination
0.0.0.0
Manager Login password
admin
Link ID
Link
Site 1
Site
Site 2
Site
Link Password
wireless-bridge
Rate
Adaptive
Ethernet Configuration
Auto Detect
Radio Link Failure Actions
No action
Bridge or Hub mode
Hub Mode, Aging time = 300 sec
Community values
Read-write – netman
Read-only – public
Front Panel LEDs on the IDU-C
The front panel LEDs on the IDU provide basic information about link status.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-9
Installation Menu and Toolbar Functionality
Chapter 4
Figure 4-8: IDU-C Front Panel LEDs
The following table describes the indicators:
Table 4-4: Front Panel LEDs
Name
Color
Function
IDU
Green
During power-up only
Green
IDU operational
Red
Failure
Green
ODU-to-IDU communication link is operating
Red
ODU-to-IDU communication link is disrupted
Green
Wireless link is synchronized
Orange
During installation mode only
Red
Wireless link lost synchronization
With Ethernet only
ODU
AIR I/F
SVC
Off
HSS
Off
Installation Menu and Toolbar Functionality
The RADWIN Manager menu functionality is displayed in table 4-5. The
Toolbar buttons are detailed in table 4-6.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-10
Installation Menu and Toolbar Functionality
Chapter 4
Table 4-5: RADWIN Manager main menu functionality
Menu level
Top
+1
Function
+2
Reference
File
Log Off
Return to Log On dialog.
Same as Log Off button
Exit
Exit the RADWIN Manager.
Same as Exit button
Link
Configuration
Run the Configuration Wizard. Not available in
installation mode
1 Configure

Provides limited configuration for site. Has a path to
return to installation
mode
2 Configure

Provides limited configuration for site. Has a path to
return to installation
mode
Link Installation
Runs the Installation Wizard. Not available in
configuration mode
Configuration
Tools
Performance
Monitoring
Report
Active Alarms
1 
Shows active alarms for

2 
Shows active alarms for

Change
Password
Change the Log On password dialog
page 4-7
page 7-10
Events Log
Preferences
Clear Events
Clear local events log
Save to File
Save events log file
Local preferences dialog
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-11
Installation Menu and Toolbar Functionality
Chapter 4
Table 4-5: RADWIN Manager main menu functionality (Continued)
Menu level
Top
+1
Function
+2
Reference
Maintenance
Clear counters
Disabled
Loopbacks
Disabled
Reset
1  Reset  ODU
2  Reset  ODU
Help
RADWIN
Manager Help
View online version of the
User Manual
Link Budget
Calculator
Calculator opened in
default browser
Appendix D
Get Diagnostics
Information
Obtain system information
page 7-1
About RADWIN
Manager
Manager build and system
information
Table 4-6: RADWIN Manager Toolbar
Item
Description
Link Configuration
Changes configuration parameters of an operating wireless link;
assigns text files for storing alarms, statistics and configuration
data. This button is disabled until a link installation has
been completed
Link Installation
Performs preliminary configuration of the system. This button is
disabled after the link is installed
Site: 
Opens the Site configuration dialog for Site A. Same as
Configuration | 1 Configure 
Site: 
Opens the Site configuration dialog for Site B. Same as
Configuration | 2 Configure 
Get Diagnostics
Obtain system information
Clear Counters
Disabled
Log off
Closes the current session and logs off RADWIN Manager
Exit
Exits RADWIN Manager
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-12
Installing the Link: Overview
Chapter 4
Installing the Link: Overview
The Installation wizard has seven steps as shown in table 4-7 below.
Table 4-7: Link Installation Wizard
Wizard welcome
System parameters
•
Link ID
•
Site details
Channel settings - ACS
Configuration
Tx power and antenna
settings
Services - Adaptive or
fixed
Wizard summary and
completion
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-13
Installing the Link: Step 1, Start the Wizard
Chapter 4
Installing the Link: Step 1, Start the Wizard
In the tool bar of the RADWIN Manager main window, click the Link
Installation button. The Link Installation button is only accessible if antennas are properly aligned. If this box is “grayed out”, you should align the
antennas as set out in Connecting and Aligning ODUs / Antennas on
page 3-13.
The Installation Wizard opens:
Figure 4-9: Link Installation Wizard
The bottom data area reproduces the corresponding data from the main
window - which the above panel obscures. See page 5-7 for a field by field
description of this data area.
Click Next to proceed with the installation procedure.
Installing the Link: Step 2, System Parameters
The system dialog box opens:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-14
Installing the Link: Step 2, System Parameters
Chapter 4
Figure 4-10: : Installation Wizard, System dialog box
 To complete Installation Step 2:
1. Enter a Link ID. (Link ID - must be unique for each link in the area). The
Link ID must include at least eight alphanumeric characters. Up to 24
characters are allowed.You should use a Link ID composed of both
alphabetic and numeric characters.
Both sides of a link must have the same Link ID.
Note
2. Enter a Link Name for the link identification. The default name is “Link”.
You should change it.
3. Enter names for Site 1 and Site 2. The default names are both “Location”. You should change them. Throughout this manual, we use A for
Site 1 and B for Site 2.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-15
Changing the Link Password
Chapter 4
4. Optionally enter a new Link Password.
Note
If the Link Password is incorrect a link is established but configuration
cannot be performed and no services are available. A new link password
may be obtained from RADWIN Customer Support or use the alternative
password supplied with the product. (see for more details).
The link password is peculiar to the link itself and should not be confused
with the RADWIN Managerlog on password.
5. Click Next.
The default link with a rate of 6.5 Mbps is evaluated.
The Channel Setting dialog box appears. Proceed to Installing the
Link: Step 3, Channel Settings, below.
Changing the Link Password
The default password is wireless-bridge. Optionally, you can change the
link password as explained here.
 To change the link password:
1. Click the Change button in the System dialog box.
The Change Link Password dialog box opens.
Use the Hide characters check box for maximum security
Note
Figure 4-11: Change Link Password dialog box
2. Enter the current link password (The default link password for a new
ODU is wireless-bridge).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-16
Installing the Link: Step 3, Channel Settings
Chapter 4
If you have forgotten the Link Password, click the Forgotten Link Password button. The following window is displayed:
Figure 4-12: Lost or forgotten Link Password recovery
Follow the instructions to use the Alternative Link Password, and click
OK to finish. You are returned to the window in figure 4-11 above.
Continue with the next step.
3. Enter a new password.
4. Retype the new password in the Confirm field.
5. Click OK.
6. Click Yes when asked if you want to change the link password.
7. Click OK at the Password changed success message.
Note
•
Restoring Factory Defaults returns the Link Password to wirelessbridge.
•
If the link is inactive, then the link password may also be changed
from the Site Configuration dialogs. See page 6-14.
Installing the Link: Step 3, Channel Settings
RADWIN 1000/2000/5000 systems have a feature called Automatic Channel
Selection (ACS). In the event of sync loss, ACS chooses the first available
channel in a list of monitored channels nominated in the Channel settings
window of figure 4-13 below. A channel switch takes place sufficiently fast
as to ensure no loss of service.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-17
Installing the Link: Step 3, Channel Settings
Chapter 4
Figure 4-13: Channel Settings - Automatic Channel Selection
The default frequency for the product is shown.
 To select channels to be used by the link:
1. Select the main frequency from the Installation Channel box.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-18
Installing the Link: Step 4, Tx Power and Antenna Settings
Chapter 4
Figure 4-14: Channel Settings - Showing available installation rates
For version 2.1, channel bandwidth is set to 20 MHz and cannot be
changed.
Note
2. Click the check box if Automatic Channel Selection is required.
3. The Available Channels List contains all of the allowable channels for the
link. Check the channels that can be automatically selected.
Selecting a new channel causes the system quality to change. The Quality bar provides an indication of the link quality from poor (red) to good
(green) as shown in the bottom of figure 4-13 above.
4. Click Next.
Installing the Link: Step 4, Tx Power and Antenna Settings
The Tx Power and Antenna Parameters dialog appears.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-19
General
Chapter 4
Figure 4-15: Transmission Power and Antenna Parameters
The choice of Tx power, antenna gain and cable loss determines the EIRP
and is affected by such considerations as radio limitations and regulatory
restrictions.
Before proceeding to antenna installation details, the following background
information should be considered:
General
Each RADWIN 1000/2000/5000 ODU is made of two radio transceivers
(radios). The radios make use of algorithms that utilize both polarization
and space diversity resulting in enhanced capacity, range and link availability. The number of antennas (i.e. radios) used is determined by user configuration and by automatic system decisions, explained below.
Dual Antennas at Both Sites
Using dual antennas at both sites (single bipolar antenna or two monopolar
antennas) enables the use of MIMO technology. With MIMO the system
doubles the link capacity. At the same time, it keeps the same rate and
modulation per radio as was used with single antenna, thus increasing
capacity, range and availability.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-20
Single Antennas at Both Sites
Chapter 4
For example with a dual antenna RADWIN 1000/2000/5000 can transmit at
modulation of 64QAM and FEC of 0.83 and get an air rate of 130 Mbps,
compared to 65 Mbps with single antenna.
To work in this mode, each antenna port must be connected to an antenna,
the RSS level in both receivers should be balanced and a minimal separation
between the antennas must be maintained. (For example, by using dual
polarization antennas a cross polarization separation is attained).
Upon selecting Antenna Type as Dual, RADWIN 1000/2000/5000 automatically doubles the air rates.
RADWIN Manager indicates a case of unbalanced RSS between the two
antennas.
Single Antennas at Both Sites
By selecting a single antenna at both sites the ODUs operate with a single
radio that is connected to the ANT 1 connector. The second radio is automatically shut down.
Single and Dual Antennas
In this mode one of the sites uses the ODU with a single antenna while the
other site uses the ODU with a dual antenna.
The advantages in this mode in comparison to using a single antenna in
both sites are doubled total Tx power and additional polarization and/or
space diversity.
RADWIN 1000/2000/5000 automatically switches to this mode if one of the
ODUs is connected to a dual antenna or if the RSS at one of the ODU receivers is below minimal level.
The air rates used in this mode are same as when using single antennas in
both sites.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-21
Considerations for Changing Antenna Parameters
Chapter 4
The rates used by RADWIN 1000/2000/5000 are shown in Table 4-5 below:
Table 4-8: RADWIN 1000/2000/5000 Transmission rates
Radio
Modulation
FEC
Air-Rate
[Mbps]
Single
BPSK
1/2
6.5
Single
QPSK
1/2
13
Single
QPSK
3/4
19.5
Single
16QAM
1/2
26
Single
16QAM
3/4
39
Single
64QAM
2/3
52
Single
64QAM
3/4
58.5
Single
64QAM
5/6
65
Dual
BPSK
1/2
13
Dual
QPSK
1/2
26
Dual
QPSK
3/4
39
Dual
16QAM
1/2
52
Dual
16QAM
3/4
78
Dual
64QAM
2/3
104
Dual
64QAM
3/4
117
Dual
64QAM
5/6
130
Considerations for Changing Antenna Parameters
Let:
maxAllowedTx Power denote the maximum Tx Power practically available from an ODU. It appears as Tx Power per Radio in
figure 4-16 below.
maxRegEIRP denote the maximum EIRP available by regulation. It will be
determined by three factors:
•
per band/regulation
•
per channel bandwidth
•
antenna gain
It appears in figure 4-16 as Max EIRP.
maxRegTxPower denote the maximum regulatory Tx Power for the
equipment, also having regard the above three points
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-22
Considerations for Changing Antenna Parameters
Chapter 4
maxODUTxPower denote the maximum Tx Power of the ODU, itself
depending on the air rate used.
Then, the following relationship must be satisfied:
maxAllowedTxPower  min(maxRegEIRP
– AntennaGain + CableLoss maxRegTxPower)
... (*)
These parameters are controlled as follows:
 To set Tx power and configure antennas:
1. Click the Configure buttons in turn to configure the antennas on both
sides of the link. Each one offers a dialog like this:
Figure 4-16: Antenna configuration dialog with opened type selection
2. Choose the antenna type and required transmission (Tx) power for the
first site and click OK. Repeat the process for the second site.
The Tx power (per radio) indicates the power of each radio inside the
ODU and is used for Link Budget Calculations. The Tx power (System)
shows the total transmission power of the ODU and is used to calculate
the EIRP according to regulations.
To see the relationship between Tx Power (radio) and TX Power (system),
note that dBm = 10  log 10milliWatt so that if you double the power in
Note
milliWatts (for two radios) then dBm will increase by 10  log 102  3 .
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-23
Considerations for Changing Antenna Parameters
Chapter 4
3. Set the Antenna Gain and Cable Loss. If do this you will receive a warning message:
Figure 4-17: Antenna parameters change warning
Note
•
The Max EIRP level will be automatically set according to the selected
band and regulation.
•
The EIRP level is the sum of the System Tx power and the Antenna
Gain minus the Cable Loss.
If inequality (*) above is violated, then the following warning window is
displayed:
Figure 4-18: Tx Power Limits
The precise relationship between the items in inequality (*) and the window of figure 4-16 is follows:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-24
Installing the Link: Step 5, Services
Chapter 4
•
Required Tx Power (per radio) will be adjusted down to the
lesser of the value entered and maxAllowedTxPower
•
TxPower (system)is maxAllowedTxPower + 3 (for 2 radios)
•
Max EIRP is maxRegEIRP.
•
EIRP is maxAllowedTx Power + Antenna Gain - Cable
Loss
The table in figure 4-18 only shows rates where the maximum Tx
Power is the limitation, rather than regulations.
Recall that maxAllowedPower and maxEIRP are regulatory. In an
unregulated environment, the only limit is maxODUTxPower.
Note
When you close the window of figure 4-18, the change you requested
will not be honored, and you will need to try again.
4. When you are finished with Tx Power configuration, Click Next.
Installing the Link: Step 5, Services
The Services dialog appears:
Figure 4-19: Services and Rates dialog
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-25
Installing the Link: Step 6, Installation Summary and Exit
Chapter 4
For version 2.1, Ethernet Only is the only available service. You may choose
a specific modulation rate or use Adaptive.
 To choose a modulation rate:
1.Choose Adaptive or one of the available rate (see page 1-4 for information about Automatic Adaptive Rate).
2. Click Next to continue.
The service is activated as show below:
Installing the Link: Step 6, Installation Summary and Exit
Figure 4-20: Installation Wizard Exit Summary
Click Done to return to the main window.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-26
Installing the Link: Step 6, Installation Summary and Exit
Chapter 4
The main window now reflects the installation:
Figure 4-21: Main window of the manager after installation
 To verify the installation:
• Verify that the Radio Signal Strength (RSS) is according to expected
results as determined by the Link Budget Calculator.
Caution
Installation mode, as described above, may be re-entered using
Configuration | 1 Configure Site A and Installation Mode the Site
Configuration dialog. Some Installation mode functionality may cause a
break in link service.
If you can accomplish link changes without breaking the service, always
prefer to use Configuration mode, described in chapter 5.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
4-27
Chapter 5
Configuring the Link
This chapter describes the link configuration procedure, which is performed
after the installation of both sides of the RADWIN 1000/2000/5000 link, as
set out in chapters 3 and 4.
Link configuration uses a Link Configuration Wizard to redefine the configuration parameters and fine-tune an operational link. Both sides of the link
are configured simultaneously.
The following parameters are configured using the Link Configuration Wizard:
•
System parameters
•
Channel settings
•
Transmission power and antenna settings
•
Service parameters
Link Configuration: Getting Started
The Main Window of the RADWIN Manager
Ensure that the RADWIN Manager is running.
The main window should look similar to that in figure 5-1:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-1
The RADWIN Manager Toolbar
Chapter 5
Figure 5-1: Main window, Wireless Link is Active
Before starting a configuration session, make sure that a communication
link exists between the two sides of the link.
The Link Status indication bar must be green. In the Link Status panel, the
Status field should show Link Active in green.
The main window of the RADWIN Manager contains a large amount of
information about the link. Before proceeding to details of link configuration
we set out the meaning of each item in the main window.
The RADWIN Manager Toolbar
In configuration mode, the RADWIN Manager toolbar contains the following
buttons:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-2
The RADWIN Manager Main Menu
Chapter 5
Table 5-1: RADWIN Manager Toolbar
Item
Description
Link Configuration
Changes configuration parameters of an operating wireless link;
assigns text files for storing alarms, statistics and configuration
data. This button is disabled until a link installation has
been completed
Link Installation
Performs preliminary configuration of the system. This button is
disabled after the link is installed
Site: 
Opens the Site configuration dialog for Site A. Same as
Configuration | 1 Configure 
Site: 
Opens the Site configuration dialog for Site B. Same as
Configuration | 2 Configure 
Get Diagnostics
Obtain system information
Clear Counters
Disabled
Log off
Closes the current session and logs off RADWIN Manager
Exit
Exits RADWIN Manager
The RADWIN Manager Main Menu
The RADWIN Manager menu, is shown in table 5-2 below:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-3
The RADWIN Manager Main Menu
Chapter 5
Table 5-2: RADWIN Manager main menu functionality
Menu level
Top
+1
Function
+2
Reference
File
Log Off
Return to Log On dialog.
Same as Log Off button
Exit
Exit the manager. Same as
Exit button
Link
Configuration
Run the Configuration Wizard. Not available in
installation mode
1 Configure

Provides limited configuration for site. Has a path to
return to installation
mode
2 Configure

Provides limited configuration for site. Has a path to
return to installation
mode
Installation
Runs the Installation Wizard. Not available in
configuration mode
Configuration
Tools
Performance
Monitoring
Report
Active Alarms
1  Shows active alarms for

2  Shows active alarms for

Change
Password
Change the Log On password dialog
page 7-10
Events Log
Preferences
page 4-7
Clear Events
Clear local events log
Save to File
Save events log file
Local preferences dialog
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-4
The RADWIN Manager Main Menu
Chapter 5
Table 5-2: RADWIN Manager main menu functionality (Continued)
Menu level
Top
+1
Function
+2
Reference
Maintenance
Clear counters
Disabled
Loopbacks
Disabled
Reset
1  Reset  ODU
2  Reset  ODU
Help
RADWIN
Manager Help
View online version of the
User Manual
Link Budget
Calculator
Calculator opened in
default browser
Appendix D
Get Diagnostics
Information
Obtain system information
page 7-1
About RADWIN
Manager
Manager build and system
information
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-5
Elements of the RADWIN Manager Main Window
Chapter 5
Elements of the RADWIN Manager Main Window
Link details pane
The Link details pane on the left is split into three sections. The top section
summarizes information about the link:
Table 5-3: Link Details
Item
Link ID
Services selected
Frequency
Channel bandwidth
Rate
Link status
The two lower panels show basic link site details:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-6
Elements of the RADWIN Manager Main Window
Chapter 5
Table 5-4: Link site details, Site A and Site B
Item
IP Address
Subnet Mask
Trap Desalination
Monitor pane
he monitor pane, is the main source of real time information about link performance at both link sites. It includes the following panes (top to bottom):
•
Radio Interface, Received Signal Strength (RSS) in dBm
•
Ethernet Service:
•
Ethernet Throughput: The numbers are the current calculated
throughputs at each site. The colored bars (with numbers) indicate the maximum possible throughput having regard for air
conditions.
•
Rx and Tx Rates: Actual Ethernet traffic received and transmitted rates per site, in Mbps of Fbps.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-7
Elements of the RADWIN Manager Main Window
Chapter 5
Figure 5-2: Ethernet Bandwidth Indication
•
Frequency box: It shows the link frequency. The color of the box
indicates the status
•
Green is an active link
•
Red is an inactive link
•
Magenta shows an authentication or compatibility problem
•
Brown shows severe compatibility problem
Events Log
The Events Log, stores alarms generated from both sides of the link and is
detailed in chapter 7, The Events Log.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-8
Elements of the RADWIN Manager Main Window
Chapter 5
Status Bar
The Status bar, displays the following icons:
Table 5-5: Status bar indicators
Icon or Label
Purpose
Connectivity
Shows if RADWIN Manager is communicating with the ODU.
Connection available
Connection mode to the ODU
• Over-the-Air connection - using the IP address of the
remote unit.
• Local connection - direct connection to the IDU without
using an IP address.
• Network connection - through a LAN
IP Address
Login IP address
Normally encrypted link
Encryption indicator
Link password validation failed. The link is encrypted with
default keys. Service and configuration are unavailable. Change
the link password.
There are several “floating” icons, which appear under specific
conditions
Note
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-9
Configuring the Link: Overview
Chapter 5
Configuring the Link: Overview
The Configuration Wizard has seven steps as shown in table 5-6 below.
Table 5-6: Link Configuration Wizard
Wizard welcome
System parameters
•
Link ID
•
Site details
Channel settings
Tx power settings
Services
Wizard summary and
completion
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-10
Configuring the Link: Step 1, Start the Wizard
Chapter 5
Since configuration functionality is included in the installation, we will briefly
review the main steps and for most part offer references to the corresponding installation step.
Configuring the Link: Step 1, Start the Wizard
In the tool bar of the RADWIN Manager main window, click the Link Configuration button. The Link Configuration button is only accessible on a
fully installed link as set out in chapter 4.
The Configuration Wizard opens:
Figure 5-3: Link Configuration Wizard
Click Next to proceed with the configuration procedure.
Configuring the Link: Step 2, System Parameters
The System dialog box opens:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-11
Configuring the Link: Step 3, Channel Settings
Chapter 5
Figure 5-4: Configuration Wizard, System dialog box
The System attributes may be edited and the Link Password may be
changed exactly as in the corresponding Link Installation step on page 414.
Click Next to continue.
Configuring the Link: Step 3, Channel Settings
Configuring the Channel Settings follows the same pattern as the Installation procedure:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-12
Configuring the Link: Step 3, Channel Settings
Chapter 5
Figure 5-5: Channel Settings dialog box - Automatic Channel Selection
Notice that the operating channel is grayed out. If you use the Reselect
Channel button, to change it, you will be asked for confirmation:
If you accept, then the system will search for the best operating channel:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-13
Configuring the Link: Step 3, Channel Settings
Chapter 5
Figure 5-6: Searching for the best operating channel
The link will return to the status of figure 5-5 above with a possible
change to the operating channel.
If you work without automatic channel selection, the Channel Settings window looks like this:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-14
Configuring the Link: Step 3, Channel Settings
Chapter 5
Figure 5-7: Channel Settings without automatic channel selection
If you click the Operating Channel drop-down list, the following window
appears:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-15
Configuring the Link: Step 3, Channel Settings
Chapter 5
Figure 5-8: Channel frequency options
Selecting one of the frequencies presented returns you to the status of
figure 5-7 with the appropriate change. If you choose Other..., the following window opens:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-16
Configuring the Link: Step 3, Channel Settings
Chapter 5
Figure 5-9: Choosing an “Other” Operating Channel frequency
The right hand drop-down list (showing 5.800) allows you to fine-tune the
frequency in increments of ±5MHz within a range of 5.740 - 5.835 GHz.
When you have completed making your choice, click Next to continue.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-17
Configuring the Link: Step 4, Tx Power and Antenna Settings
Chapter 5
Configuring the Link: Step 4, Tx Power and Antenna
Settings
Figure 5-10: Transmission Power and Antenna Parameters
If you chose to configure either antenna, you are presented with the following window:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-18
Configuring the Link: Step 4, Tx Power and Antenna Settings
Chapter 5
Figure 5-11: Antenna configuration dialog with opened type selection
So far, the procedure duplicates the corresponding Installation process on.
If you choose a different antenna type and click OK, you will receive the following cautionary message:
In this context, entering Installation mode causes a service break until it is
restored by running the Installation wizard.
Caution
If you are uncertain, do not do this without expert technical
assistance.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-19
Configuring the Link: Step 5, Services
Chapter 5
You may also change the Required Tx Power, Antenna Gain and Cable Loss.
The procedure is the same as that set out in the Installation procedure on
page 4-23.
When you have completed making your choice, proceed to the Services
window.
Configuring the Link: Step 5, Services
Here is the services dialog:
Figure 5-12: Services and Rates dialog
To choose Services, see the corresponding Installation procedure on
page 5-20.
Click Next to continue.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-20
Configuring the Link: Step 6, Configuration Summary and Exit
Chapter 5
Configuring the Link: Step 6, Configuration Summary and
Exit
Figure 5-13: Configuration Wizard Exit Summary
Click Done to return to the main window.
The main window now reflects the configuration:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-21
Configuring the Link: Step 6, Configuration Summary and Exit
Chapter 5
Figure 5-14: Main window of the manager after configuration
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
5-22
Chapter 6
Site Configuration
The Site Configuration dialog panels are used to configure parameters,
which may differ between both sides of the link.
The parameters configured using the Site Configuration dialog panels
include (among others):
•
System settings
•
Air interface - Transmit (Tx) power and antenna
•
Network management including VLAN
•
Security settings
•
Date and time
•
Hub or Bridge mode
In addition, the Link Site Configuration panels include several information
windows:
•
Inventory - link hardware and software model details
•
External alarms indicators
The Operations dialog offers a “doorway” to jump into installation mode
reverting to factory settings.
The Site Configuration dialog has its own main menu with the following
extra functionality:
•
Backup configuration parameters to a text file
•
Restore configuration from a previously backed up configuration file
•
Enable/disable the site ODU buzzer
•
Jump back into installation mode keeping current configuration settings
Configuring the Site
Editing the Configuration Parameters by Site
You can edit the configuration parameters for each site individually. The following functions are available from the left side of the dialog box.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-1
Editing the Configuration Parameters by Site
Chapter 6
Figure 6-1: Configuration Dialog Box
Functions on the left of the dialog box:
System
Edit the contact person and location details.
View the system details
Air Interface
Change the transmit power, cable loss, antenna
type and settings
Inventory
View the hardware and software inventory
(release numbers, model identification, MAC
address)
Management
Configure the IP address, Subnet Mask, Default
Gateway, the Trap Destination and VLAN
Security
Change the Community Values and the Link
Password
Date and Time
Set the date and time of the link from an NTP
servers otherwise
Advanced
Choose Hub or Bridge ODU mode, set the
Ethernet ports configuration, set the external
alarm inputs, restore factory settings
Functions at the top of the dialog box:
Backup
Save the current configuration to an .ini file
Restore
Restore the link configuration from the .ini file
created by the backup
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-2
Viewing Air Interface Details
Chapter 6
Installation
Mode
Return to Installation Mode for the entire link.
Mute
Mutes the alignment tone in installation mode.
Reactivate the beeper during alignment.
Selecting the Mute check box before clicking
the Install Mode button mutes the Beeper.
 To edit the Configuration Parameters:
1. Click the required site button on the main tool bar of the RADWIN Manager
OR
Click Configuration from the main menu and choose a site to configure.
The Configuration dialog box opens (see figure 6-1 above).
2. Choose the appropriate item in the left hand list to open a dialog box.
3. Click Apply to save changes.
In subsequent instructions, we will simply say “Choose a site to configure”
on the understanding that the foregoing procedure is implied.
Viewing Air Interface Details
Click the Air Interface item in the left hand list. A window similar to the following appears:
Figure 6-2: Air interface details
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-3
Changing the Transmit Power
Chapter 6
Changing the Transmit Power
Each site can have a different transmit power level.
 To change the Transmit Power:
1. Choose a site to configure.
The Configuration dialog box opens.
2. Choose Air Interface (see figure 6-3).
3. Choose the required Transmit (Tx) Power Level.
4. Click Apply to save the changes.
Figure 6-3: Changing the Transmit Power
The same considerations apply here as were noted in the Installation
procedure on page 4-23.
Note
Site Management: IP Address and VLAN
Configuring the ODU Address
Each site must be configured separately, first site A then site B.
 To define the Management Addresses:
1. Choose a site to configure.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-4
Configuring VLAN Settings
Chapter 6
The Configuration dialog box opens:
Figure 6-4: Management Addresses - Site Configuration dialog box
5. Choose Management.
6. Enter the IP address of the ODU in the IP Address field.
If performing configuration from the RADWIN Manager, the IP address is
that entered from the login screen.
Note
7. Enter the Subnet Mask.
8. Enter the Default Gateway.
9. Enter the Trap Destination. This could be the IP address of the managing
computer. The events log will be stored at this address.
10.Click Apply to save the changes.
Configuring VLAN Settings
VLAN Management enables separation of user traffic from management
traffic whenever such separation is required. It is recommended that both
sides of the link be configured with different VLAN IDs for management traffic.
 To enable VLAN management:
1. Click Configuration from the main menu.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-5
Configuring VLAN Settings
Chapter 6
2. Choose a site to configure. If you are configuring both sites, choose site
B first.
3. Choose Management.
4. Open the VLAN tab.
5. Check the Enabled box.
6. Enter a VLAN ID. Its value should be between 1 and 4094.
After entering the VLAN ID, only packets with the specified VLAN ID are
processed for management purposes by the ODU. This includes all the
protocols supported by the ODU (ICMP, SNMP, TELNET and NTP). The
VLAN priority is used for the traffic sent from the ODU to the managing
computer. Using VLAN for management traffic affects all types of management connections (local, network and over the air).
7. Enter a Priority number between 0 and 7.
8. Change the VLAN ID and Priority of the managing computer NIC to be
the same as those of steps 6 and 7 respectively.
9. Click Apply or OK.
Figure 6-5: Configuring management traffic VLAN Settings
Caution
Changing this parameter causes the RADWIN Manager to immediately
disconnect.To avoid inconvenience, you should verify the change by
setting the VLAN only to one ODU, and only after verifying proper
management operation, change the other ODU VLAN setting.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-6
Setting the Date and Time
Chapter 6
Lost or forgotten VLAN ID
If the VLAN ID is forgotten or there is no VLAN traffic connected to the
ODU, then reset the relevant ODU.
During the first two minutes of connection to the ODU uses management
packets both with and without VLAN. You may use this period to reconfigure
the VLAN ID and priority.
Setting the Date and Time
The ODU maintains a date and time. The date and time should be synchronized with any Network Time Protocol (NTP) version 3 compatible server.
During power-up the ODU attempts to configure the initial date and time
using an NTP Server. If the server IP address is not configured or is not
reachable, a default time is set.
When configuring the NTP Server IP address, you should also configure the
offset from the Universal Coordinated Time (UTC). If there is no server
available, you can either set the date and time, or you can set it to use the
date and time from the managing computer. Note that manual setting is not
recommended since it will be overridden by a reset, power up, or synchronization with an NTP Server.
The NTP uses UDP port 123. If a firewall is configured between the ODU
and the NTP Server this port must be opened.
Note
It can take up to 8 minutes for the NTP to synchronize the ODU date and
time.
 To set the date and time
1. Determine the IP address of the NTP server to be used.
2. Test it for connectivity using the command (Windows XP), for example:
w32tm /stripchart /computer:216.218.192.202
You should get a continuous response of times, each a few seconds
apart.
3. Choose a site to configure.
The Configuration dialog box opens.
4. Choose Date & Time:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-7
Setting the Date and Time
Chapter 6
Figure 6-6: Date and Time Configuration
5. If entering an IP address for the NTP Server, click Clear, and then enter
the new address.
6. Set your site Offset value in minutes ahead or behind GMT1.
7. To manually set the date and time, click Change and edit the new values.
Figure 6-7: Change Date and Time
If you used an NTP Server, you will see a window like this:
1. Greenwich Mean Time
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-8
Ethernet Properties
Chapter 6
Figure 6-8: Date and Time configured from an NTP Server
8. Click OK to return to the Configuration dialog.
Ethernet Properties
Configuring the Bridge
Bridge configuration is required in various network topologies, such as protection (1+1) and ring applications. The bridge configuration parameters
are located under the Advanced tab of the Site Configuration dialog box:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-9
Configuring the Bridge
Chapter 6
Figure 6-9: Bridge Configuration - Site Configuration dialog box
ODU Mode
This parameter controls the ODU mode with two optional values,
•
Hub Mode - in Hub mode the ODU transparently forwards all packets
over the wireless link.
•
Bridge Mode - In Bridge mode the ODU performs both learning and
aging, forwarding only relevant packets over the wireless link. The
aging time of the ODU is fixed at 300 seconds.
Changing these modes requires system reset.
Note
IDU Aging time
This parameter controls the IDU aging time.
The aging time parameter controls the time after which each MAC address
is dropped from the MAC address learning table.
The default value is 300 seconds.
Note
•
Any change to these parameters is effective immediately.
•
Each side of the link can be configured separately.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-10
Configuring Ethernet Ports Mode
Chapter 6
The following table shows the appropriate configuration for several common
scenarios. Both link sites must be configured with the same parameter:
Table 6-1: ODU mode configuration for common
ODU
Mode
IDU Aging
Time
Standard (Default) Configuration for
Ethernet Applications
Bridge
300 sec
Rapid network topology changes
where fast aging is required
Hub
1 sec
Ethernet Hub
Hub
N/A
Ethernet Bridge
Bridge
N/A
Scenario
Configuring Ethernet Ports Mode
The ODU Ethernet port is configured to auto-detect by default and may not
be changed.
The ODU Ethernet port mode is configurable for line speed (10/100BaseT)
and duplex mode (half or full duplex).
An Auto Detect feature is provided, whereby the line speed and duplex
mode are detected automatically using auto-negotiation. Use manual configuration when attached external equipment does not support auto-negotiation. The default setting is Auto Detect.
Caution
You should not reconfigure the port that is used for the managing computer
connection, since a wrong configuration can cause a management
disconnection or Ethernet services interruption.
 To configure the Ethernet Mode:
1. From the Configuration menu, choose the site to reconfigure.
The Site Configuration dialog box opens.
2. Click Advanced | Ethernet.
3. In the Ethernet Ports Configuration pane, use the drop-down menu to
choose the configuration.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-11
Setting the Maximum Information Rate
Chapter 6
4. Click Apply to save the changes.
It is possible to close the Ethernet service by disconnecting the Ethernet
port.
Note
If you close the port, you may subsequently be unable to access the
device. If this should occur, a workaround is as follows:
•
Connect the system from the remote site
•
Connect via other Ethernet port (of the IDU)
•
Power down the equipment and connect immediately after power
up (the fastest way is to enter install mode)
Setting the Maximum Information Rate
The maximum Ethernet throughput of the link can be limited. The default
setting is Not Limited (see figure 6-9 above), where the highest information rate available for the link conditions and settings is used.
 To limit the Ethernet information rate:
1. From the Configuration menu, choose the site to reconfigure.
2. Click Advanced | Ethernet
The Configuration dialog box opens.
3. In the Information Rate pane, use the drop-down menu to choose the
maximum Information Rate.
4. Choose Other to define the throughput with 1 Kbps resolution
5. Choose Not Limited for the highest information rate possible for the
link conditions and settings
6. Click Apply to save the changes.
Displaying the Inventory
 To view the inventory data
1. Choose a site from the main menu.
The Configuration dialog box opens.
2. Choose Inventory (figure 6-10).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-12
Security Features
Chapter 6
Figure 6-10: Inventory Screen
Security Features
The Security dialog enables you to change the Link Password and the SNMP
Communities details:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-13
Changing the Link Password
Chapter 6
Figure 6-11: Available security features
Changing the Link Password
This item is only available when the link is down. Otherwise, it works the
same way as the corresponding item on page 4-16.
RADWIN Manager Community Strings
The ODU communicates with the application using SNMPv1 protocol. The
protocol defines three types of communities:
•
Read-Only for retrieving information from the ODU
•
Read-Write to configure and control the ODU
•
Trap used by the ODU to issue traps.
The Community string must be entered at login. The user must know the
password and the correct Community string to gain access to the system. A
user may have read-only privileges.
It is not possible to manage the ODU if the read-write or the read Community values are forgotten. A new Community value may be obtained from
RADWIN Customer Support for the purpose of setting new Community; the
serial number or the MAC address of the ODU must be supplied.
Note
The RADWIN Manager uses the Read Community strings public for the site
Al ODU and public-remote for the site B ODU. It uses Write Community
strings netman for the site A ODU and netman-remote for the site B
ODU. These are the factory defaults.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-14
RADWIN Manager Community Strings
Chapter 6
The read-write Community strings and read-only Community strings have a
minimum of five alphanumeric characters. (bru1 and bru4097 are not permitted). Changing the trap Community is optional and is done by clicking
the check box.
Editing Community Strings
The Community change dialog box is available from the Configuration |
Security tab. Both read-write and read-only communities must be defined.
On logging on for the first time, use the following as the current Community:
•
For Read-Write Community, use netman.
•
For Read-Only Community, use public.
•
For Trap Community, use public
 To change a Community string:
1. From the Configuration dialog box, choose the Security tab.
2. Type the current read-write Community (default is netman).
3. Choose the communities to be changed by clicking the check box.
4. Type the new Community string and re-type to confirm.
5. Click OK to save.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-15
RADWIN Manager Community Strings
Chapter 6
Figure 6-12: Changing the Community String
Forgotten Community string
If the read-write Community string is unknown, an alternative Community
key can be used. The alternative Community key is unique per ODU and can
be used only to change the Community strings. The alternative Community
key is supplied with the product, and should be kept in a safe place.
If both the read-write Community and the alternative Community key are
unavailable, then an alternative Community key can be obtained from RADWIN Customer Support using the ODU serial number or MAC address. The
serial number is located on the product label. The serial number and the
MAC address are displayed in the Site Configuration inventory tab.
When you have the alternative Community key, click the Forgot Community button and enter the Alternative Community key (figure 6-13). Then
change the read-write Community string.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-16
Muting the alignment tone
Chapter 6
Figure 6-13: Alternative Community Dialog box
Muting the alignment tone
The ODU alignment tone becomes audible as soon as power is supplied,
and continues until the ODUs are aligned and the link established.
It is possible to mute the tone during regular operation of the link. It must
be enabled when performing the alignment procedure.
 To mute the alignment tone:
1. Choose a site.
2. The Configuration dialog box opens.
3. In the Configuration dialog box, click the Buzzer button. The button toggles between on and off.
The tone is disabled.
 To restore the alignment tone:
1. Choose a site.
The Configuration dialog box opens.
2. In the Configuration dialog box, click the Buzzer button. The button toggles from on to off. The tone is enabled.
Setting External Alarm Inputs
The IDU-C has two external alarm inputs and two external alarm outputs in
the form of dry-contact relays. The Alarm interface is located on the front
panel of the IDU-C and is a 25-pin D-type female connector. see IDU-C
Alarm Connector on page B-3, for wiring specifications and pinout. The
user enables or disables each of the alarms and can configure the alarm
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-17
Managing Configuration Files
Chapter 6
description text that appears in the alarm trap. The ODU sends the alarm
within less than a second from actual alarm trigger.
 To set the external alarm inputs:
1. Open the Site Configuration Alarms configuration by clicking Configuration | Advanced.
Figure 6-14: External Alarm Configuration
2. Choose an alarm and set its mode to Enabled or Disabled
3. Enter a description of the alarms in the text field.
4. Click Apply to save.
5. Click OK to exit from the dialog.
Managing Configuration Files
Backup Configuration to a File
RADWIN Manager allows you to backup configuration parameters of the
local and remote units to the managing computer as .ini files. Each site is
backed up in a separate .ini file.
 To save the configuration in a file:
1. Choose a site to back up.
The Configuration dialog box opens.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-18
Restoring a Configuration File
Chapter 6
2. Click Backup.
3. In the Save As dialog box, indicate in which folder and under what name
configuration file is to be saved, and click Save.
Restoring a Configuration File
Configuration files (*.ini) can be uploaded from the managing computer.
Such configuration files can be distributed to other units that use the same
configuration.
 To restore a configuration file:
1. Choose a site to restore (from a previous backup).
The Configuration dialog box opens.
2. Click Restore.
3. From the Open dialog box choose *.ini file to upload and click OK.
Backup files are specific to a site (IDU / ODU pair and Link ID).
Caution
Do not restore a backup configuration file to a site other than that from
which it was originally taken.
Resetting
You may reset the link, preserving the current configuration, or reset to factory defaults.
Resetting the link causes service disconnection.
Caution
To maintain the connection between the managing computer and
the link, first reset Site B.
 To reset the link preserving current configuration:
1. From Maintenance on the main window, reset the remote unit.
2. From Maintenance on the main window, reset the local unit.
 To reset to Factory Defaults
1. Choose either of the sites.
The Configuration dialog box opens.
2. Choose Operations in the Configuration dialog box.
3. Click the Restore Defaults button.
A message box asking if you want to restore factory default appears.
4. Click the check box if you want to keep the current IP address settings.
5. Click Yes to continue.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-19
Configuration with Telnet
Chapter 6
Configuration with Telnet
A Telnet terminal can be used to configure and monitor the RADWIN 1000/
2000/5000.
To start a Telnet session, use telnet .
For example, if you run Telnet as follows,
telnet 10.0.0.120
you will be asked for a user name and password.
The login user name/password is identical to the Community strings; Read
allows display only, Read/Write allows display and set commands.
Supported Telnet commands are shown in table 6-2. Note that some of
the commands are model-specific. For example, TDM commands will not
apply to Ethernet only and PoE based links.
Table 6-2: Telnet Commands
Command
Explanation
display inventory
Displays ODU product name, Name, Location, hardware
and software revisions, uptime, MAC address, IDU product
name, IDU software and hardware revisions
display management
Displays IP, Subnet, Gateway, Traps table
display link
Displays State, Link ID, Channel BW, RSS, TSL,
Frequency/ACS, DFS, Rate/ARA, Distance
display Ethernet
Displays Bridge Mode, Aging time, Port table (State, Status
and action)
display tdm
Displays Clock Mode, Master Clock Mode, Current Clock,
Quality[1], TDM table (Line status, Error Blocks)
display ntp
Displays Time, Server and Offset
set ip  

Set the ODU IP address, subnet mask and gateway
The user must reset the ODU after the command
completion
display PM


Shows the performance monitor tables for each interface
according to user defined monitoring intervals
set trap  

Set a specific trap from the traps table (set trap 3
10.0.0.133 162)
set readpw  
Set the read access password (Read Community)
set writepw  
Set the read-write access password (Read-Write
Community)
set trappw  
Set the trap Community string
set buzzer 
Toggle the buzzer mode (0 – off, 1 – on)
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-20
Configuration with Telnet
Chapter 6
Table 6-2: Telnet Commands (Continued)
Command
Explanation
set tpc
Set the ODU transmit power. If a wrong value is entered,
both min and max values shall be displayed in the error
reply
set bridge 
Set the ODU bridge mode (0 – off, 1 – on)
set name 
Set the name of the link
set location 
Set the name of the location
Set contact 
Set the name of the site manager
set Ethernet <>port:MNG,LAN1,LAN2>

Set the mode and speed of each ethernet port
Reboot
Reset both the IDU and the ODU. The user shall be
prompt that the command will reset the card and that he
has to reconnect the telnet session after TBD seconds.
Help
Displays the available commands
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-21
Configuration with Telnet
Chapter 6
figure 6-15, below, shows the available Telnet commands via the Help
command.
Hello admin, welcome to ODU Management CLI!
+-----------------------------------------------------------+
Software Revision
2.1.00_b2070_Jun 5 2008
+-----------------------------------------------------------+
admin@10.0.0.120-> Type "help" for help.
admin@10.0.0.120-> help
display inventory
display management
display link
display ethernet
display tdm
display ntp
display PM 

set ip   
set trap   
set readpw  
set writepw  
set trappw  
set buzzer 
set tpc 
set bridge 
set name 
set location 
set contact 
set ethernet  
reboot
help
Command "help" finished OK.
Figure 6-15: Telnet Management Screen
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
6-22
Chapter 7
Monitoring and
Diagnostics
The RADWIN Manager application enables you to monitor the link, as well
as perform diagnostic operations such as loopback tests.
This chapter covers:
•
Retrieving link information
•
Link compatibility issues
•
Reinstalling and realigning a link
•
Performance monitoring
•
Troubleshooting
•
Replacing an ODU
•
Restoring to factory setup
Retrieving Link Information (Get Diagnostics)
The Get Diagnostics feature collects and writes all link and Manager information (from both sites) into a text file. The file information can be used for
diagnostics and should be sent to RADWIN Customer Support to speed up
assistance.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-1
Retrieving Link Information (Get Diagnostics)
Chapter 7
The following table lists link and system information that can be monitored.
Table 7-1: Get Diagnostics Data and Description
Data
Description
System Data
General information about the system
Link Information
Information about the link properties
Events Log
List of recent system events
Site Configuration
Data about the site parameters
Active Alarms
List of active alarms
Performance Monitor
Network performance data over defined time periods
Monitor
Detailed event data record
 To get diagnostics
1. On the Help menu, choose Get Diagnostic Information.
Figure 7-1: Get Diagnostics Dialog Box
2. Select or deselect the data options. If the file is to be sent to RADWIN
Customer Support leave all options checked.
3. Click File Path to specify the folder in which you want to save the file
and then click Start to save the information.
The file is saved in the specified folder as Diagnostics Information.txt
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-2
Link Compatibility
Chapter 7
Link Compatibility
Link Compatibility indicates the version compatibility using software traps.
As new hardware or software is added to existing networks compatibility
issues may arise. An incompatibility issue is indicated to the user by a
change of color of the Link Status box on the Main Menu screen. Trap messages in the events Log indicate the problems or limitations and suggest
upgrades when appropriate.
The following Link Status messages are given:
fullCompatibility - different software versions were detected that are fully
compatible. The message indicates that an upgrade is available.
restrictedCompatibility - different software versions were detected that
operate correctly. However, new features are not supported
softwareUpgradeRequired - different software versions were detected allowing limited operation. The message is, that a software upgrade required.
versionsIncompatibility - different software versions were detected that are
incompatible. You need to perform local upgrades.
Table 7-2: Link Compatibility Trap Messages
Link State
Link State
text
Link
Status
Color
Site
Desc.
Color
Link Status
Color
fullCompatibility
Active
Green
SW Upgrade
Available
Yellow
Green
restrictedCompatibility
Active - SW
Version
mismatch
Magenta
(Same as
authentication
error)
SW Upgrade
Recommended
Yellow
Magenta
(Same as
authentication
error)
softwareUpgradeRequired
Active – SW
Upgrade
Required
Brown
(Major)
SW Upgrade
Required
Yellow
Brown (Major)
versionsIncompatibility
Not Active SW
Upgrade
Required
Red
Local SW
Upgrade
Required
Yellow
Red
Site
Description
Reinstalling and Realigning a Link
It may be necessary to reinstall the link if the ODUs need to be realigned.
Activating Install Mode causes both sites to go into install mode, causing
disruption in service for approximately fifteen seconds.
Note
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-3
The Link Budget Calculator
Chapter 7
 To reinstall the link:
1. Choose a site.
The Configuration dialog box opens.
2. In the Configuration dialog box, click the Install Mode button.
A message box asking if you want to enter install mode appears.
3. Click Yes to continue.
The system enters Install mode and the alignment tone becomes audible.
4. Realign the ODUs and start the Installation wizard (see chapter 4).
The Link Budget Calculator
The Link Budget Calculator is part of the RADWIN Manager software and is
found in the Help menu. This useful utility enables you to calculate the
expected performance of the wireless link and the possible configurations
for a specific link range including antenna size, cable loss and climate conditions. For full details, see appendix D.
Performance Monitoring
RADWIN 1000/2000/5000 Performance Monitoring constantly monitors traffic over the radio link and collects statistics data for the air interface and
Ethernet ports. It does so continuously, even when the RADWIN Manager is
not connected.
Two types of logs are recorded:
•
Monitor Log that records statistics on traffic rate and radio signal
strength.
•
Events Log that records when the rates fall above or below a predefined threshold.
Both the statistics Monitor log and events log can be saved as TXT files.
The Monitor Log
The Monitor Log records performance statistics for predefined intervals. You
can save the monitor log to a text file, as well as display the information in
an on-screen report.
Saving the Monitor Log
You can save the recorded Monitor Log statistics to a text file.
 To save the monitor log:
1. From the Tools menu, choose Preferences.
The Preferences dialog box appears:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-4
The Monitor Log
Chapter 7
Figure 7-2: Preferences dialog box
2. Click the Monitor Tab.
3. Select the file to save.
4. Click the check box to open the file for saving.
5. Click the
button and in the Select File dialog box indicate in which
folder and under what name the monitor log file is to be saved.
6. Set the time interval for adding data to the file.
7. Click OK to save the file.
Viewing Performance Reports
The Performance Monitor Report displays performance views of each of the
interfaces1.
 To obtain performance monitoring reports:
1. From the main menu, choose Tools | Performance Monitoring
Report ...
You are presented with the following window:
1. Ethernet performance is not collected from PoE devices.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-5
The Monitor Log
Chapter 7
Figure 7-3: Basic Performance Monitoring Report
2. Choose a report type from the left panel and click the Get Data toolbar
button. For example, if you choose Site A, Air and Current, you will be
offered a report looking like this:
Figure 7-4: A typical Performance Monitoring Report
You can click the Selection Pane icon to toggle the side panel on or off.
The other reports look similar. Here is a detailed description of the reports
and their fields:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-6
The Monitor Log
Chapter 7
Several performance data occurrences are collected for each of the interfaces (ES, SES, and UAS), as well as Specific data per Interface type (e.g.,
TX and RX bytes for Ethernet). For the Air Interface, user defined thresholds
data are collected. Refer to table 7-3 and table 7-4, in Performance
Monitoring Report Toolbar below.
Data is collected and selectively displayed based on three time intervals as
selected by the Interval radio buttons:
•
Current (t=0)
•
15 minutes Intervals
•
Daily
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-7
The Monitor Log
Chapter 7
Table 7-3: Explanation of performance data
Data type
Generic PM Data
Air Interface PM
Data
Ethernet Interface
PM Data
Reported Value
Explanation
UAS – Unavailable
Seconds
Seconds in which the interface was out of service.
ES – Errored Seconds
The number of seconds in which there was at least
one error block. Note that the notation of an error
block is different per interface.
SES – Severe Errored
Seconds
The number of seconds in which the service quality
was low (the quality is different per type of interface and determined by the BBER threshold per
interface).
BBE – Background
Block Error
The number of errored blocks in an interval.
Integrity
A flag indicating that the data was valid. Note that
the Performance Monitoring data is not valid if not
all the values were stored (e.g., due to clock
changes within the interval or power up reset).
Max RSL
The maximum of the receive signal level (measured in dBm).
Min RSL
The minimum of the receive signal level (measured
in dBm).
Max TSL
The maximum of the transmit signal level (measured in dBm).
Min TSL
The minimum of the transmit signal level (measured in dBm).
RSL Threshold 1
The number of seconds in which the RSL was
below the specified threshold.
RSL Threshold 2
The number of seconds in which the RSL was
below the specified threshold.
TSL Threshold
The number of seconds in which the RSL was
above the specified threshold.
BBER Threshold
The BBER Threshold value counts the number of
seconds in which the Background Block Error Ratio
(BBER) exceeded the specified threshold.
Received Bytes
The number of Megabytes received at the specified
port within the interval
Transmitted Bytes
The number of Megabytes transmitted at the specified port within the interval.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-8
The Monitor Log
Chapter 7
Performance Monitoring Report Toolbar
You can use the toolbar to perform the actions described in the following
table:
Table 7-4: Action of the toolbar buttons
Command Button
Action
Get Data
Gathers current performance monitoring data.
Save
Save current performance monitoring data to a file
Clear
Clear current performance monitoring data.
Thresholds
Set Air Interface Thresholds
Close
Closes the active alarm window.
Setting Air Interface Thresholds
Use the Thresholds button on the Monitoring Performance Report toolbar to
set the Air Interface Thresholds:
Figure 7-5: Threshold configuration dialog box
BBER Threshold
This parameter counts the seconds during which the radio performance is
below a user specified threshold. The threshold is measured as a percentage. The threshold can be set from 0.1% up to 50%.
For links with Ethernet only service, 8% threshold is recommended. If there
are no problems during the interval, then for that threshold, the recommended BBER value should be 0. Since the system provides a lossless
Ethernet service, there is throughput degradation in case of interference.
The degradation is proportional to the BBER.
RSL Threshold
RSL Threshold can also be used as an indicator of problems in the radio
channel. You can check the RSS by from the Link Budget Calculator results
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-9
The Events Log
Chapter 7
during installation. A value of -5dB from the current RSS is recommended as
a threshold.
The Events Log
The Events Log records system failures, loss of synchronization, loss of signal, compatibility problems and other fault conditions and events.
Alarms (traps) are displayed in the Events Log in the lower panel of the
main window. The Events Log may be saved as a text file.
The Events Log includes the following fields:
Sequential number (ID)
Date and time stamp
Message
Trap source
IP address of the ODU that initiated alarm.
For complete information about traps and alarms see appendix F, MIB Reference, table F-3.
The events are displayed in the Events Log in the lower part of the RADWIN
Manager main window:
Figure 7-6: Events Log Display
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-10
RADWIN Manager Traps
Chapter 7
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events,
displayed in the Wvents Log.
Table 7-5: RADWIN Manager Trap Messages
Trap Message
Severity
Remarks
Error loading trap catcher. Port 162 is already in use.
Warning
NMS will not catch any
traps from target, some
other application has
grabbed this port
Device unreachable!
Error
Check connectivity to target
Connected to 
Information
 Site will be reset.
Information
Restore Factory Default Settings in process on Site

Information
Factory Settings: The process was not finished due to
connection issues.
Warning
Factory setting failed due to
connectivity problem to target
Reset: The process was not finished due to connection issues.
Warning
Factory setting failed due to
connectivity problem to target - Target will not be
reset
Cannot Write to Monitor file. There is not enough
space on the disk.
Warning
Free some space on disk
and retry
Windows Error: . Cannot Write to Monitor
file.
Warning
Operating System error
TDM Counters were cleared for both sides
Information
Identical IP addresses at  and

Warning
Set up a different IP to each
site
The Product is not identified at the
 site.
Warning
NMS is incompatible with
the target release
The Product is not identified at the
 site.
Warning
The Product is not identified at both sites.
Warning
Product Not Identified!
Warning
The Manager identified a newer ODU release at the
 site.
Warning
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
ODU release is newer than
NMS release. Wizards are
not available. NMS will be
used just for monitoring.
Upgrade the NMS. (You will
get this message as a pop
up)
7-11
RADWIN Manager Traps
Chapter 7
Table 7-5: RADWIN Manager Trap Messages
Trap Message
Severity
The Manager identified a newer ODU release at both
sites.
Warning
The Manager identified a newer ODU release at the
 site.
Warning
Newer Version identified at the 
site.
Warning
Newer Version identified at the 
site.
Warning
Newer Version Identified!
Warning
Remarks
ODU release is newer than
NMS release. Wizards are
not available. NMS will be
used just for monitoring.
Upgrade the NMS
Setting the Events Preferences
You can define a color for the traps to be displayed in the Event Log window, according to the severity of the event. The severity is predefined.
 To set the trap color:
1. From the Tools menu, choose Preferences.
The Preferences dialog box appears.
2. Click the Events Tab:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-12
RADWIN Manager Traps
Chapter 7
Figure 7-7: Preferences dialog box
3. Select the event type and click on the
button.
A color chart opens.
4. Select the desired color.
5. Repeat for all of the event types.
 To set the trap background color:
• Click Background Color to change the text background.
 To reset the event colors:
• Click Reset Settings to return to the default color settings.
Saving the Events Log
You can save recorded events in an Events Log text file. New alarms are
automatically added to the text file, as they enter the Events Log.
 To save the Events Log:
1. From the Tools menu, choose Preferences.
The Preferences dialog box appears
2. Click the Events Tab.
3. Select the file to save.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-13
RADWIN Manager Traps
Chapter 7
4. Click the check box to open the file for saving.
Click the
button and in the Select File dialog box indicate in which folder
and under what name the Events Log file is to be saved, and click OK.
Note
To store the Events Log, first define the IP address, subnet mask, default
gateway and trap address of the managing computer (see Configuring
the ODU Address on page 6-4 for details).
Reverting Alarm Messages
Alarm messages can be reverted to their default values by choosing the
Advanced tab from the Preferences dialog:
Just click the Restore Defaults button, followed by OK.
Active Alarms
Upon setting a trap destination, applicable events are reported as active
alarms to the user. The active alarms are saved and can be viewed in the
Active Alarms window.
 To view summary of saved alarms:
• From the Tools menu, choose Active Alarm Summary.
The Active Alarms Summary window opens:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-14
RADWIN Manager Traps
Chapter 7
Figure 7-8: Active Alarms Summary
The following table provides an explanation of the command buttons
Table 7-6: Active Alarms command buttons
Command
Action
Save
Saves the alarms in CSV or text format for further analysis.
Refresh
Reads the alarms from the ODU.
Site
Selects site for the active alarms.
Close
Closes the active alarm window.
Remote Power Fail Indication
Remote power fail indication indicates to one side that the other side has
had a power failure. The failed site sends a final trap indication about the
power loss just before powering off.
A “Dying-Gasp” circuit identifies the power failure at a minimum interval of
20 milliseconds before the ODU or IDU powers off. During that interval a
message notifying the power failure is sent to Site B. Alarm output number
4 indicates power failure at Site B.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-15
Troubleshooting
Chapter 7
Troubleshooting
Use the following table to troubleshoot LED fault indications:
Table 7-7: LED fault indicators
LED
Status
Remedy
PWR
Off
Check that AC adapter is connected to the IDU-E and the AC
power outlet.
IDU
Orange
Check that the IDU/ODU cable is properly wired and connected.
ODU
Red
Check that the IDU/ODU cable is properly wired and connected.
AIR I/F
Orange
Complete the installation procedure from the management software.
Red
Check the ODU Antenna alignment. Check that the radio configuration of both site A and site B units are the same (channel and
Link ID).
SVC
Off
Use the following table to troubleshoot faults in the system:.
Table 7-8: Troubleshooting
Symptom
Remedy
No power
Ensure that power is connected to the IDU.
Ensure that the ODU cable is properly wired and connected.
No signal
Complete the installation procedure from the RADWIN Manager
Check the ODU alignment. Check that the radio configuration of both site A
and site B units are the same (channel and Link ID.
Weak signal
received
Check the ODU alignment, reconfigure the link.
Check the alignment tone sounds the Best Signal sequence.
Replacing an ODU
Prior to any action ensure that both ODUs have the same software version.
You can see this on the inventory panels for each site.
For Site A, click Site A | Inventory and note the ODU software version.
Repeat this for Site B using Site B | Inventory.
If either ODU has an old software version, perform a software upgrade. It is
important to configure the new ODU exactly the same as the old ODU to
avoid configuration mismatches, which will disrupt the link.
An ODU may be reconfigured in several ways.
•
Use the backup Configuration
If a backup of the configuration is available, restore that configuration using Site A| Restore.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-16
Restoring Factory Setup
•
Chapter 7
Manual Configuration
The new ODU can be configured manually according to the link configuration. Remember to use the same settings for Link ID, channels, link password, IP addresses, and names.
Restoring Factory Setup
 To restore factory setup:
1. Set the remaining ODUs back to the factory setup by using the Site A
|Advanced option.
2. Activate the second ODU and carry out a new Installation.
Online Help
Online help can be accessed from the Help menu on the main screen of the
RADWIN 1000/2000/5000 Manager.
Figure 7-9: Online Help for RADWIN 1000/2000/5000
Customer Support
Customer support for this product can be obtained from the local VAR, Integrator or distributor from whom it was purchased.
For further information, please contact the RADWIN 1000/2000/5000 distributor nearest to you or one of RADWIN's offices worldwide (see RADWIN Worldwide Offices at the beginning of this manual).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
7-17
Appendix A
Technical Specifications
Configuration
Architecture
ODU: Outdoor Unit with Integrated Antenna or Connectorized for External Antenna
IDU: Indoor Unit for service interfaces or PoE device for
Ethernet only
IDU to ODU Interface
Outdoor CAT-5e cable; Maximum cable length: 100 m
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
A-1
Radio
Appendix A
Radio
Capacity
Up to 270Mbps at 40MHz channel bandwidth in the 5.3/5.4
IC and 5.8 GHz spectrum bands
Up to 130Mbps at 20MHz channel bandwidth in the 3.5/3.6
GHz spectrum bands
Range
Up to 120 km / 75 miles
Frequency Bands
Channel Bandwidth
Band
5.725 – 5.850 GHz
Band
Regulations
5.725 – 5.850 GHz
FCC / IC
5.725 – 5.825 GHz
5.250 – 5.350 GHz (excluding FCC(UNII)/IC
FCC
40 MHz channel bandwidth
and 6dBi antenna assembly
gain)
5.250 – 5.350 GHz (including
IC
40 MHz channel bandwidth
and 6dBi antenna assembly
gain)
5.470 – 5.725 GHz (excluding FCC
40 MHz channel bandwidth
and 6dBi antenna assembly
gain)
IC
5.470 – 5.725 GHz (including
40 MHz channel bandwidth
and 6dBi antenna assembly
gain)
FCC / IC
4.940 – 4.990 GHz
FCC / IC
2.400 – 2.4835 GHz
FCC / IC
3.650 – 3.700 GHz
IC
3.475 – 3.650 GHz
5, 10, and 20 MHz
40 MHz in the 5.3/5.4 IC and 5.8 GHz spectrum bands
Max Tx Power
Antenna
29.95 dBm
28 dBi Dish
29.95 dBm
24 dBi Integral Flat
29.95 dBm
23 dBi External Flat
23 dBm
14 dBi External Flat
20 dBm
16.5 dBi External Flat
28 dBm
8 dBi assembly
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
A-2
Radio
Appendix A
Band
5.250 – 5.350 GHz
5.470 – 5.725 GHz
5.725 – 5.825 GHz
4.940 – 4.990 GHz
2.400 – 2.4835 GHz
3.475 – 3.650 GHz
3.650 – 3.700 GHz
Max Tx Power
Antenna
1.9 dBm
28 dBi Dish
6.5 dBm
23.5 dBi Integral Flat
7.5 dBm
22.5 dBi External Flat
23.5dBm
6 dBi assembly
7.4 dBm
14 dBi External Flat
7.4 dBm
15.5 dBi External Flat
23.5 dBm
6 dBi assembly
1.6 dBm
28 dBi Dish
6.3 dBm
23.5 dBi Integral Flat
7.3 dBm
22.5 dBi External Flat
23.7 dBm
6 dBi assembly
7.2 dBm
14 dBi External Flat
7.2 dBm
16.5 dBi External Flat
23.7 dBm
6 dBi assembly
23.8 dBm
28 dBi Dish
26.4 dBm
22.5 dBi Integral Flat
26.4 dBm
23.5 dBi External Flat
29.4 dBm
6 dBi assembly
24.4 dBm
14 dBi External Flat
24 dBm
16.5 dBi External Flat
29.3 dBm
6 dBi assembly
31 dBm
21 dBi Integral Flat
31 dBm
21 dBi External Flat
31 dBm
28 dBi Dish
31 dBm
14 dBi External Flat
31 dBm
15 dBi External Flat
25.5 dBm*
20 dBi External Flat
25.5 dBm*
17.5 dBi Integral Flat
23.7 dBm
20 dBi External Flat
23.7 dBm
17.5 dBi Integral Flat
26 dBm
21 dBi Integral Flat
26 dBm
22 dBi External Flat
26 dBm
25 dBi Dish
25.6 dBm
13.5 dBi assembly
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
A-3
Ethernet Interface
Appendix A
Channel Bandwidth
5, 10, and 20 MHz, (10MHz not supported in the 5.8 GHz
band)
Radio Modulation
2x2 MIMO-OFDM (BPSK/QPSK/16QAM/64QAM)
Adaptive Modulation & Coding Supported
Automatic Channel Selection
Supported
Radio Regulation
FCC 47 CFR Part 15 Subpart C, E, Part 90 Subpart Y, Z
IC (Canada) RSS-210, RSS-111, RSS-192, RSS-197
Duplex Technology
TDD
Error Correction
FEC k = 1/2, 2/3, 3/4, 5/6
Rate – Single Antenna [Mbps] 6.5
13
19.5
26
39
52
58.5
65
Rate – Single Antenna in the
5.8 GHz spectrum band
[Mbps]
13.5
27
40.5
54
81
108
121.5
135
Rate – Dual Antenna [Mbps]
13
26
39
52
78
104
117
130
54
81
108
162
216
243
270
Rate –Dual Antenna in the 5.8
27
GHz spectrum band [Mbps]
BPSK
Modulation
FEC [k=]
1/2
1/2
3/4
25
Max Tx Power [dBm]
Sensitivity (dBm) @BER <10e-88
11 (20MHz)
Encryption
QPSK
-86
-83
16QAM
64QAM
1/2
3/4
2/3
24
21
19
-81
-80
-72
3/4
5/6
18
-70
-67
AES 128
* Relevant for RADWIN 1000 RW-1020-0150 / RADWIN 2000 RW-20200150 models only
Ethernet Interface
Throughput
Up to 270Mbps in the 5.3/5.4 IC and 5.8 GHz spectrum
bands
Number of Ethernet ports
IDU-C and E: 2; PoE Device: 1
Type
10/100BaseT with Auto-Negotiation (IEEE 802.3u)
Framing/Coding
IEEE 802.3
Line Impedance
100 Ω
VLAN Support
Transparent
Connector
RJ-45
Maximum Frame Size
2048 Bytes
Bridge
Layer 2, self-learning of up to 2047 MAC addresses (IEEE
802.1Q), hub/Bridge selectable mode
Latency
3 msec (typical)
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
A-4
Management
Appendix A
Management
Management Application
RADWIN Manager
Protocol
SNMP and Telnet
Mechanical
Dimensions
ODU with Integrated Antenna: 37.1/14.84(W) x 37.1/
14.84(H) x 9.00/3.6(D) cm/in; 3.5 kg / 7 lbs
ODU Connectorized: 18.0/7.2(W) x 27.0/10.8(H) x 5.5/
2.2(D) cm/in; 1.5 kg / 3.0 lbs
IDU-C: 43.6/17.2(W) x 4.5/1.7(H) x 21/8.3(D) cm; 1.5 kg /
3.3 lbs
IDU-E: 22/8.7(W) x 4.4/1.7(H) x 17/6.7(D) cm/in; 0.5 Kg /
1.1 lbs
Power
Power Feeding
Dual feeding, -20 to -60 VDC (AC/DC converter is available)
Power Consumption
< 35 W (IDU+ODU)
Environmental
Operating Temperatures
Humidity
ODU: -35°C to +60°C / -31°F to +140°F
IDU-C: 0°C to +50°C / 32°F to +122°F
IDU-E: -5°C to 45°C / 32°F to 122°F
ODU: Up to 100% non-condensing, IP67
IDU: 90% non-condensing
Safety
FCC/IC (cTUVus)
UL 60950-1, CAN/CSA 60950-1 C22.2
ETSI
EN/IEC 60950-1
EMC
FCC
CFR47 Class B, Part15, Subpart B
ETSI
EN 300 386 (2005), EN 301 489-1 (2001), EN 301 489-4
(2002)
CAN/CSA-CEI/IEC
CISPR 22-02
AS/NZS
CISPR 22:2002
Air Interface
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
A-5
Air Interface
Appendix A
RADWIN 1000/2000/5000 is available in several different frequency band
ranges that comply with ETSI, FCC and IC regulations.
The RADWIN 1000 RW-1020-0150 / RADWIN 2000 RW-2020-0150 is available only in the 2.4GHz frequency band range that complies with FCC and
IC regulations.
The RADWIN 1000 3GHz Band / RADWIN 2000 3GHz Band / RADWIN 5000
3GHz Band support the 3.5 / 3.6 GHz frequency bands and comply with FCC
and IC regulations.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
A-6
Appendix B
Wiring Specifications
ODU-IDU Cable
The ODU-IDU cable is shielded/outdoor class CAT-5e, 4 twisted-pair 24
AWG terminated with RJ-45 connectors on both ends. A cable gland on the
ODU side provides hermetic sealing.
The following table shows the connector pinout:
Table B-1: ODU-IDU Connector Pinout
ODU
RJ-45
Function
Color
IDU RJ-45
Ethernet (RxN)
White/Green
Ethernet (RxT)
Green
twisted
pair
Ethernet (TxT)
White/Orange
Orange
twisted
pair
Ethernet (TxN)
Power (+)
Blue
White/Blue
twisted
pair
Power (+)
Power ()
White/Brown
Power ()
Brown
twisted
pair
User Port Connectors
LAN Port
The LAN 10/100BaseT interface terminates in an 8-pin RJ-45 connector,
wired in accordance to table B-2.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
B-1
LAN Port
Appendix B
Table B-2: Fast Ethernet Connector Pinout
Pin
Signal
Function
TD (+)
Transmit Data
(positive)
TD (–)
Transmit Data
(negative)
RD (+)
Receive Data
(positive)
RD (–)
Receive Data
(negative)
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
B-2
IDU-C Alarm Connector
Appendix B
IDU-C Alarm Connector
The IDU-C Alarm interface is a 25 pin D type female connector. Its pinout is
listed in table B-3.
Table B-3: IDU-C Alarm Connector (Dry-Contact)
I/O
Description
Pin
Input 1
Positive
14
Input 1
Negative
15
Input 2
Positive
16
Input 2
Negative
17
Input 3
Positive
18
Input 3
Negative
19
Input 4
Positive
20
Input 4
Negative
21
Output 1
Normally Open
Output 1
Common
Output 1
Normally
Closed
Output 2
Normally Open
Output 2
Common
Output 2
Normally
Closed
Output 3
Normally Open
Output 3
Common
Output 3
Normally
Closed
Output 4
Normally Open
10
Output 4
Common
11
Output 4
Normally
Closed
12
The following diagram describes how to connect external input and output
alarms.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
B-3
IDU-C Alarm Connector
Note
Appendix B
•
Use an external current limit resistor to limit the current at the output
relays to 1 Ampere. Such resistor is not required if the equipment
connected to the IDU supports current limiting to 1 Amp.
•
The voltage of the input alarm must be within the range of -10 to -50
VDC.
Figure B-1: Example for connecting the alarm connector
DC Power Terminal
Table B-4: Terminal Block 3-pin -48VDC
Function
Pin
Right
Chassis
Center
–
Left
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
B-4
Appendix C
Pole and Wall Installation
ODU Mounting Kit Contents
Table C-1: Bill of Materials: ODU mounting kit
Item
Qty
Large Clamp (see figure C-1)
Small Clamp (see figure C-2)
Arm (see figure C-3)
Screw hex head M8x40
Screw hex head M8x70
Washer flat M8
Washer spring M8
M8 Nuts
FigureC-1:LargeClamp FigureC-2:SmallClamp
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
Figure C-3: Arm
C-1
Mounting RADWIN 1000/2000/5000 on a pole
Appendix C
Mounting RADWIN 1000/2000/5000 on a pole
Figure C-4: Mounting on a pole
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
C-2
Mounting RADWIN 1000/2000/5000 on a Wall
Appendix C
Mounting RADWIN 1000/2000/5000 on a Wall
Figure C-5: Mounting on a Wall
Mounting an External Antenna
Optional external antennas can be mounted on a pole. The external mounting kit varies according to the specific antenna.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
C-3
Appendix D
Link Budget Calculator
Overview
The Link Budget Calculator is a utility for calculating the expected performance of the RADWIN 1000/2000/5000 wireless link and the possible configurations for a specific link range.
The utility allows you to calculate the expected RSS of the link, and find the
type of services and their effective throughput as a function of the link
range and deployment conditions.
User Input
You are required to enter or choose the following parameters. Depending
on the product, some of the parameters have a default value that cannot be
changed.
•
Product (or Regulation and Band)
•
Channel Bandwidth (fixed to 20 MHz for RADWIN 1000/2000/5000)
•
Tx Power (maximum Tx power per modulation is validated)
•
Antenna Type (cannot be changed for ODU with integrated antenna)
•
Antenna Gain per site (cannot be changed for integrated antenna)
•
Cable Loss per site (cannot be changed for integrated antenna)
•
Required Fade Margin
•
Rate (and Adaptive check box)
•
Service Type (Ethernet Only for RADWIN 1000/2000/5000 version
2.1)
•
Required Range
Link Budget Calculator Internal Data
For each product (or Regulation and Band) the calculator stores the following data required for link budget calculations:
•
Maximum Transmit power (per modulation)
•
Receiver Sensitivity (per modulation) for Ethernet service and for
TDM services at various BER
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-1
Calculations
Appendix D
•
Maximum linear input power (used to calculate minimum distance)
•
Antenna gain and cable loss for ODU with integrated antenna
•
Available Channel Bandwidths
Calculations
EIRP
EIRP = TxPower + AntennaGain SiteA – CableLoss SiteA
Expected RSS and Fade Margin
ExpectedRSS = EIRP – PathLoss + AntennaGain SiteB – CableLoss SiteB
where:
Site A is the transmitting site
Site B is the receiving site
PathLoss is calculated according to the free space model,
PathLoss = 32.45 + 20  log 10 frequency MHz  + 20  log 10 RequiredRange Km 
ExpectedFadeM arg in = Sensitivity – ExpectedRSS
where Sensitivity is dependent on air-rate.
Min and Max Range
MinRange is the shortest range for which
ExpectedRSS  MaxInputPower per air-rate.
MaxRange (with Adaptive checked) is the largest range for which
ExpectedRSS  Sensitivity , at the highest air-rate for which this relationship is true. In a link with adaptive rate this will be the actual behavior.
MaxRange (for a given air-rate) is the largest range for which
ExpectedRSS  Sensitivity + RequiredFadeM arg in .
Service
The Ethernet throughput is calculated according to internal product algorithms.
Availability
The Service Availability calculation is based on the Vigants Barnett method
which predicts the downtime probability based on a climate factor (C factor).
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-2
Antenna Height
Appendix D
Availability = 6  10
 10
–7
 Cfactor  frequency GHz   RequiredRange KM 
–-----------------------------------------------------------ExpectedFadeM arg in10
Antenna Height
The recommended antenna height required for line of sight is calculated as
the sum the Fresnel zone height and the boresight height. See About the
Fresnel Zone below.
The Fresnel zone height is calculated as:
ExpectedRange 2
300
------------------------------------  ----------------------------------------2
frequency GHz
0.6  -------------------------------------------------------------------------------------------ExpectedRange ExpectedRange
----------------------------------------- + ----------------------------------------2
The boresight clearance height is calculated as:
Maean
ExpectedRange
+ ----------------------------------------2
– R Maean
where R Mean = 6367.4425Km .
Running the Link Budget Calculator
The Link Budget Calculator is supplied on the RADWIN Manager CD. It may
be run stand-alone from the CD or from the RADWIN Manager application.
 To run the Link Budget Calculator from the CD:
1. Insert the RADWIN Manager CD into the drive on the managing computer. In the window which opens, click the Link Budget Calculator
option.
2. If the CD autorun application does not start by itself, then point your
browser to
Z:\RADWIN\Setup\DATA\Link Budget Calculator.htm
where Z should be replaced with your own CD drive name.
 To run the Link Budget Calculator from the RADWIN Manager:
• Choose Help | Link Budget Calculator from the main menu of the
RADWIN Manager as in the following figure:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-3
Running the Link Budget Calculator
Appendix D
Figure D-1: Accessing the Link Budget Calculator
However invoked, your browser displays the following page:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-4
Running the Link Budget Calculator
Appendix D
Figure D-2: Link Budget Screen
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-5
Running the Link Budget Calculator
•
Appendix D
Microsoft Internet Explorer users may see a warning message like
this:
Click the yellow bar and follow the instructions to allow blocked
content.
Note
•
Mozilla FireFox and Google Chrome users may see a warning message like this:
You may ignore it and continue.
 To use the Link Budget Calculator for RADWIN 1000/2000/5000:
1. Choose a product from the drop-down list (or choose a Regulation and
Band):
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-6
Running the Link Budget Calculator
Appendix D
Figure D-3: Product selector
2. Enter the radio details. Note that Rate is chosen from a drop-down list:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-7
Running the Link Budget Calculator
Appendix D
Figure D-4: Rate selector
The Rate shown, defines the air-interface rate in Mbps. The system
operates in TDD mode and has the overhead of the air-interface protoco.l Thus, the Ethernet actual throughput is provided by the Ethernet
Rate.
For a given air-rate, Ethernet throughput will decrease with increasing range
due to propagation delay.
Note
The Fade margin is the minimum required for LOS conditions. For
degraded link conditions, a larger Fade margin should be used.
The EIRP is given in dBm and Watts.
3. If the required range between the two link sites is known, you may enter
it directly. Alternatively, you may enter the latitude and longitude of each
site in the link, in which case the distance between them will be calculated and displayed.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-8
Running the Link Budget Calculator
Appendix D
Figure D-5: Calculation of distance from site coordinates
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-9
Running the Link Budget Calculator
Appendix D
4. Located to the right of the green Coordinates button is a dropdown list of
Climactic C Factor values.
Figure D-6: Climactic C Factors
For help about what these mean, click the ? button to the right of the list
in figure D-6.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-10
Running the Link Budget Calculator
Appendix D
Figure D-7: Climactic C Factor description
In figure D-8 we display a map of the world showing C Factor contours:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-11
Running the Link Budget Calculator
Appendix D
Figure D-8: World map showing C Factor contours
5. Click Calculate to obtain the required performance estimate.
Placing the cursor in any other calculated field will also update the
calculated results.
Note
The Expected Performance parameters are calculated and displayed:
•
Expected RSS - the expected RSS that the RADWIN Manager
shows when the RADWIN 1000/2000/5000 ODUs are optimally
aligned
•
Ethernet Rate - maximum throughput available for the chosen
parameter combination
•
Antenna height for LOS – the minimum antenna height required
for line-of-sight operation. It is the sum of the height required for
boresight clearance due to the earth’s curvature plus the height
required to clear the Fresnel zone
If the expected performance is not suitable for your application, try different
parameters and repeat the calculation.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-12
About the Fresnel Zone
Appendix D
About the Fresnel Zone
The Fresnel zone (pronounced "frA-nel", with a silent “s”) is an elliptically
shaped conical zone of electromagnetic energy that propagates from the
transmitting antenna to the receiving antenna. It is always widest in the
middle of the path between the two antennas.
Figure D-9: Fresnel zone
Fresnel loss is the path loss occurring from multi-path reflections from
reflective surfaces such as water, and intervening obstacles such as buildings or mountain peaks within the Fresnel zone.
Radio links should be designed to accommodate obstructions and atmospheric conditions, weather conditions, large bodies of water, and other
reflectors and absorbers of electromagnetic energy.
The Fresnel zone provides us with a way to calculate the amount of clearance that a wireless wave needs from an obstacle to ensure that the obstacle does not attenuate the signal.
There are infinitely many Fresnel zones located coaxially around the center
of the direct wave. The outer boundary of the first Fresnel zone is defined
as the combined path length of all paths, which are half wavelength (1/2 )
of the frequency transmitted longer than the direct path. If the total path
distance is one wavelength (1 ) longer than the direct path, then the outer
boundary is said to be two Fresnel zones. Odd number Fresnel zones reinforce the direct wave path signal; even number Fresnel zones cancel the
direct wave path signal.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-13
About the Fresnel Zone
Appendix D
The amount of the Fresnel zone clearance is determined by the wavelength
of the signal, the path length, and the distance to the obstacle. For reliability, point-to-point links are designed to have at least 60% of the first Fresnel
zone clear to avoid significant attenuation.
The concept of the Fresnel zone is shown in figure D-9 above. The top of
the obstruction does not extend far into the Fresnel zone, leaving 60% of
the Fresnel zone clear; therefore, the signal is not significantly attenuated.
For more about Fresnel zone, see http://en.wikipedia.org/wiki/
Fresnel_zone.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
D-14
Appendix E
Lightning Protection and
Grounding Guidelines
Meticulous implementation of the guidelines in this appendix will provide
best protection against electric shock and lightning.
100% protection is neither implied nor possible.
Warning
This appendix is at best a guide. The actual degree of lightning protection
required depends on local conditions and regulations.
Note
The RADWIN 1000/2000/5000™ Lightning protection system consists of the
following components:
•
Grounding for the antenna coax cable
•
Grounding for each IDU and ODU
•
External Primary Surge Suppressor units and grounding for the outdoor cable
•
Internal ESD protection circuits over the Power/Telecom lines
Grounding for Antenna Cable
A Grounding Kit must be connected to the coax antenna cable and reliably
grounded as shown in Figure X. The grounding kit is an Andrew Type
223158-2 (www.andrew.com). See figure E-1 below.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-1
Grounding for Indoor/Outdoor Units
Appendix E
Figure E-1: Grounding antenna cables
Grounding for Indoor/Outdoor Units
ODU Grounding
RADWIN 1000/2000/5000™ uses a Shielded CAT-5e cable to interconnect
the Outdoor (ODU) and Indoor (IDU) units.
However, this shielding does not provide a good Lightning Discharge path,
since it can not tolerate the high Lightning Current surges.
To provide an alternate Lightning Discharge path, the ODU and antenna
grounding posts should be connected to ground point by a 10 AWG short
copper wire.
The device should be permanently connected to ground.
IDU Grounding
The IDUs grounding post should be connected to the internal ground point,
using a grounding wire of at least 10 AWG. The grounding wire should be
connected to a grounding rod or the building grounding system.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-2
External Lightning Surge Suppressors and Grounding
Appendix E
The device should be permanently connected to ground.
External Lightning Surge Suppressors and Grounding
A Grounding Kit and Surge Arrestor Unit must be located near the ODU and
properly grounded as illustrated in figure E-2 and figure E-3 below:
Figure E-2: Grounding a typical pole installation
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-3
External Lightning Surge Suppressors and Grounding
Appendix E
Figure E-3: Grounding a typical wall installation
The next figure shows a close-up of the rear of grounded ODU:
Figure E-4: ODU Surge Suppressor and grounding
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-4
External Lightning Surge Suppressors and Grounding
Appendix E
The Transtector protection circuits shown in figure E-5 below, utilize silicon avalanche diode technology. The unit consists of an outdoor rated
NEMA 3R type enclosure with easy mounting flanges, ground stud attachment and easy wiring.
The ALPU-POE features RJ-45 protection circuits for the ODU-IDU data pairs
(pins 1,2 & 3,6) and DC power (pins 4,5 & 6,7 with the pairs bonded).
The unit is designed to be wall mounted. An optional set of bracket is available to allow a wide range of pole mount applications. A dedicated ground
stud is provided inside the unit that must be bonded to the nearest grounding system (or Master Ground bar) for proper surge protection.
The system wiring is installed with RJ-45 type connectors that can feed
directly into the chassis without having to cut, splice or route through awkward strain relief holes.
Figure E-5: Transtector’s Surge Suppressor
 To mount the lightning protection devices:
1. Mount the device as close to the ODU as possible. Mount the unit so that
the cable connectors are at the bottom (to prevent water from penetrating), with the strain reliefs facing the ground.
2. Remove the cover by unscrewing the front of the unit.
3. Mount the unit to an outside surface using the two mounting holes.
4. Connect the ODU-IDU cable using the RJ-45 jack.
5. Connect one cable between the ODU and the suppressor using an RJ-45
jack.
6. Connect the suppressor’s ground stud to a grounding point. Use the
appropriate wire gauge and type, keeping the wire as short as possible,
less than 1m (3’), between the stud and the site grounding point.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-5
External Lightning Surge Suppressors and Grounding
Appendix E
7. Replace the cover.
Note
There may also be regulatory requirements to cross bond the ODU-IDU CAT5e cable at regular intervals up the mast. This may be as frequent as every
10 meters (33 feet).
A second Surge Arrestor Unit should be mounted at the building entry point
and must be grounded, as shown in figure E-3 above.
 To mount the lightning protection at the building entry point:
1. Mount the device outside the building, located as near as possible to the
entrance of the CAT-5e ODU-IDU cable. Mount the unit so that the cable
connectors are at the bottom (to prevent water from penetrating), with
the strain reliefs facing the ground.
2. Remove the cover by unscrewing the front of the unit.
3. Mount the unit to an outside surface using the two mounting holes.
4. Connect the ODU-IDU cable using the RJ-45 jack.
5. Connect one cable between the IDU and the suppressor using an RJ-45
jack.
6. Connect the suppressor’s ground stud to a grounding point. Use the
appropriate wire gauge and type, keeping the wire as short as possible,
less than 1m (3’), between the stud and the site grounding point.
7. Replace the cover
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-6
Internal ESD Protection circuits
Appendix E
Figure E-6: Surge Suppressor and grounding at building entry point
Internal ESD Protection circuits
RADWIN 1000/2000/5000™ is designed to meet the ETSI/FCC/Aus/NZ/CSA
EMC and Safety requirements. To fulfill these requirements, the system's
Telecom lines at the ODU/IDU are Transformer-isolated and include internal
ESD (Electro-Static-Discharge) Protection circuits.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
E-7
Appendix F
MIB Reference
Introduction
About the MIB
The RADWIN MIB is a set of APIs that enables external applications to control RADWIN equipment.
The MIB is divided into public and a private API groups:
•
Public: RFC-1213 (MIB II) variables, RFC-1214 (MIB II) System and
Interfaces sections
•
Private: Controlled by RADWIN and supplements the public group.
This appendix describes the public and private MIB used by RADWIN.
Terminology
The following terms are used in this appendix.
Term
Meaning
MIB
Management Information Base
API
Application Programming Interface
SNMP
Simple Network Management Protocol
In addition, the MIB uses internally, the older notions of Local site and
Remote site where this manual would use site A and site B.
To avoid burdening the reader, this appendix will follow the MIB usage.
Interface API
Control Method
The RADWIN Manager application provides all the means to configure and
monitor a RADWIN 1000/2000/5000 link, communicating with the SNMP
agent in each ODU. Each SNMP agent contains data on each of the IDUs
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-1
Community String
Appendix F
and ODUs in the link. Both agents communicate with each other over the air
using a proprietary protocol.
Each ODU has a single MAC address and a single IP address.
Note
To control and configure the device using the MIB, you should adhere to the
following rules:
•
The connection for control and configuration is to the local site, over
any SNMP/UDP/IP network.
•
All Parameters should be consistent between both of the ODUs. Note
that inconsistency of air parameters can break the air connection. To
correct air parameters inconsistency you must reconfigure each of
the ODUs.
•
Common practice is to configure the remote site first and then to
configure the local site.
•
For some of the configuration parameters additional action must be
taken before the new value is loaded. Please refer to the operation
in the parameters description.
•
Some of the MIB parameters values are product dependent. It is
strongly recommend using the RADWIN Manager Application for
changing these values. Setting wrong values may cause indeterminate results.
Community String
To control a link, all SNMP requests should go to the local site IP address.
The RADWIN Manager uses the Read Community strings public for the
local ODU and public-remote for the remote ODU. It uses Write Community strings netman for the local ODU and netman-remote for the
remote ODU. These are the factory defaults.
Private MIB Structure
The sections in the private RADWIN MIB and its location in the MIB tree are
shown in figure F-1 below:
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-2
Private MIB Structure
Appendix F
Figure F-1: Top Level Sections of the private MIB
The products MIB section contains the definition of the Object IDs for the
two form factors of the ODU, Integrated Antenna and Connectorized
(referred in the MIB as external antenna):
The ODU MIB contains the sections: Admin, Service, Ethernet, Bridge, Air,
PerfMon and Agent.
The IDU MIB contains the sections: Admin, Service, Ethernet, Bridge and
TDM.
The general MIB include a single generic parameter that is used by all traps
as a trap description parameter.
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-3
MIB Parameters
Appendix F
MIB Parameters
The following section describes all of the MIB parameters. The MIB parameters follow the following naming convention:
...
For each of the configuration and control parameters (parameters with read-write access), the “Description” column describes when the new value is effective. It is recommended that you perform the appropriate action to make the values affective immediately after any change. Where a change is required on both sides of the link, it is recommended that you change both sides of the link first and then perform the action. Supported Variables from the RFC 1213 MIB Table F-1: Supported RFC 1213 Variables (Sheet 1 of 2) Access Name OID Type ifIndex .1.3.6.1.2.1.2.2.1.1.xa Integer RO A unique value for each interface.Its value ranges between 1 and the value of ifNumber.The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. ifDescr .1.3.6.1.2.1.2.2.1.2 DisplayString RO A textual string containing information about the interface.This string should include the name of the manufacturer, the product name and the version of the hardware interface. ifType .1.3.6.1.2.1.2.2.1.3 Integer RO The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack. ifSpeed .1.3.6.1.2.1.2.2.1.5 Gauge RO An estimate of the interface's current bandwidth in bits per second.For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should ontain the nominal bandwidth. ifPhysAddress .1.3.6.1.2.1.2.2.1.6 Phys-Address RO The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length. ifAdminStatus .1.3.6.1.2.1.2.2.1.7 Integer RW The desired state of the interface. The testing(3) state indicates that no operational packets can be passed. ifOperStatus .1.3.6.1.2.1.2.2.1.8 Integer RO The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. ifInOctets .1.3.6.1.2.1.2.2.1.10.x Counter RO The total number of octets received on the interface, including framing characters. ifInUcastPkts .1.3.6.1.2.1.2.2.1.11.x Counter RO The number of subnetwork-unicast packets delivered to a higher-layer protocol. ifInNUcastPkts .1.3.6.1.2.1.2.2.1.12.x Counter RO The number of non-unicast (i.e., subnetworkbroadcast or subnetwork-multicast) packets delivered to a higher-layer protocol. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 Description F-4 MIB Parameters Appendix F Table F-1: Supported RFC 1213 Variables (Sheet 2 of 2) Access Name OID Type Description ifInErrors .1.3.6.1.2.1.2.2.1.14.x Counter RO The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. ifOutOctets .1.3.6.1.2.1.2.2.1.16.x Counter RO The total number of octets transmitted out of the interface, including framing characters. ifOutUcastPkts .1.3.6.1.2.1.2.2.1.17.x Counter RO The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent. ifOutNUcastPkts .1.3.6.1.2.1.2.2.1.18.x Counter RO The total number of packets that higher-level protocols requested be transmitted to a nonunicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent. a. x is the interface ID MIB Parameters Table F-2: Private MIB Parameters (Sheet 1 of 14) OID Type Access Name Description winlink1000OduAdmProductType 1.3.6.1.4.1.4458.1000.1.1.1 DisplayString RO ODU configuration description. winlink1000OduAdmHwRev 1.3.6.1.4.1.4458.1000.1.1.2 DisplayString RO ODU Hardware Version. winlink1000OduAdmSwRev 1.3.6.1.4.1.4458.1000.1.1.3 DisplayString RO ODU Software Version. winlink1000OduAdmLinkName 1.3.6.1.4.1.4458.1000.1.1.4 DisplayString RW Link Name. A change is effective immediately. winlink1000OduAdmResetCmd 1.3.6.1.4.1.4458.1000.1.1.5 Integer RW Reset Command. A set command with a value of 3 will cause a device reset. The read value is always 0. winlink1000OduAdmAddres 1.3.6.1.4.1.4458.1000.1.1.6 IpAddress RW ODU IP address. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended. winlink1000OduAdmMask 1.3.6.1.4.1.4458.1000.1.1.7 IpAddress RW ODU Subnet Mask. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended. winlink1000OduAdmGateway 1.3.6.1.4.1.4458.1000.1.1.8 IpAddress RW ODU default gateway. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended. winlink1000OduAdmBroadcast 1.3.6.1.4.1.4458.1000.1.1.10 Integer RW This parameter is reserved for the Manager application provided with the product. winlink1000OduAdmHostsTable N/A Trap destinations table. Each trap destination is defined by an IP address and a UDP port. Up to 10 addresses can be configured. winlink1000OduAdmHostsEntry N/A Trap destinations table entry. winlink1000OduAdmHostsIndex winlink1000OduAdmHostsIp RO 1.3.6.1.4.1.4458.1000.1.1.12.1.2 IpAddress RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 Trap destinations table index. RW Trap destination IP address. A change is effective immediately. F-5 MIB Parameters Appendix F Table F-2: Private MIB Parameters (Sheet 2 of 14) Access Name OID Type winlink1000OduAdmHostsPort 1.3.6.1.4.1.4458.1000.1.1.12.1.3 Integer RW UDP port of the trap destination. A change is effective immediately. winlink1000OduBuzzerAdminState 1.3.6.1.4.1.4458.1000.1.1.13 Integer RW This parameter controls the activation of the buzzer while the unit is in install mode. A change is effective immediately. The valid values are: disabled (0) enabled (1). winlink1000OduProductId 1.3.6.1.4.1.4458.1000.1.1.14 DisplayString RO winlink1000OduReadCommunity 1.3.6.1.4.1.4458.1000.1.1.15 DisplayString RW Read Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read Community String. The SNMP agent accepts only encrypted values. winlink1000OduReadWriteCommunity 1.3.6.1.4.1.4458.1000.1.1.16 DisplayString RW Read/Write Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read/Write Community String. The SNMP agent accepts only encrypted values. winlink1000OduTrapCommunity 1.3.6.1.4.1.4458.1000.1.1.17 DisplayString RW Trap Community String. This parameter is used by the Manager application to change the Trap Community String. The SNMP agent accepts only encrypted values. winlink1000OduAdmSnmpAgentVersion 1.3.6.1.4.1.4458.1000.1.1.18 Integer RO Major version of the SNMP agent. winlink1000OduAdmRemoteSiteName 1.3.6.1.4.1.4458.1000.1.1.19 DisplayString RO Remote site name. Returns the same value as sysLocation parameter of the remote site. winlink1000OduAdmSnmpAgentMinorVe rsion 1.3.6.1.4.1.4458.1000.1.1.20 Integer RO Minor version of the SNMP agent. winlink1000OduAdmLinkPassword 1.3.6.1.4.1.4458.1000.1.1.21 DisplayString RW Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password. The SNMP agent accepts only encrypted values. winlink1000OduAdmSiteLinkPassword 1.3.6.1.4.1.4458.1000.1.1.22 DisplayString RW Site Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password of the site. The SNMP agent accepts only encrypted values. winlink1000OduAdmDefaultPassword 1.3.6.1.4.1.4458.1000.1.1.23 Integer RO This parameter indicates if the current Link Password is the default password. winlink1000OduAdmConnectionType 1.3.6.1.4.1.4458.1000.1.1.24 Integer RO This parameter indicates if the Manager application is connected to the local ODU or to the remote ODU over the air. A value of 'unknown' indicates community string mismatch. winlink1000OduAdmBackToFactorySetti ngsCmd 1.3.6.1.4.1.4458.1000.1.1.25 Integer RW Back to factory settings Command. A change is effective after reset. The read value is always 0. winlink1000OduAdmIpParamsCnfg 1.3.6.1.4.1.4458.1000.1.1.26 DisplayString RW ODU IP address Configuration. The format is: ||| winlink1000OduAdmVlanID 1.3.6.1.4.1.4458.1000.1.1.27 Integer RW VLAN ID. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware. winlink1000OduAdmVlanPriority 1.3.6.1.4.1.4458.1000.1.1.28 Integer RW VLAN Priority. 0 is lowest priority 7 is highest priority. winlink1000OduAdmSN 1.3.6.1.4.1.4458.1000.1.1.29 DisplayString RO winlink1000OduSrvMode 1.3.6.1.4.1.4458.1000.1.2.1 Integer RW System mode. The only value that can be set is installMode; normalMode reserved to the Manager application provided with the product. A change is effective after link re-synchronization. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 Description This parameter is reserved for the Manager application provided with the product. IDU Serial Number F-6 MIB Parameters Appendix F Table F-2: Private MIB Parameters (Sheet 3 of 14) Access Name OID Type winlink1000OduSrvBridging 1.3.6.1.4.1.4458.1000.1.2.3 Integer RO Bridging Mode. Valid values are: disabled (0) enabled (1). winlink1000OduEthernetRemainingRate 1.3.6.1.4.1.4458.1000.1.3.1 Integer RO Current Ethernet bandwidth in bps. winlink1000OduEthernetIfTable Description N/A ODU Ethernet Interface table. winlink1000OduEthernetIfEntry N/A ODU Ethernet Interface table entry. winlink1000OduEthernetIfIndex 1.3.6.1.4.1.4458.1000.1.3.2.1.1 Integer RO ODU Ethernet Interface Index. winlink1000OduEthernetIfAddress 1.3.6.1.4.1.4458.1000.1.3.2.1.5 DisplayString RO ODU MAC address. winlink1000OduEthernetIfAdminStatus 1.3.6.1.4.1.4458.1000.1.3.2.1.6 Integer RW Required state of the interface. winlink1000OduEthernetIfOperStatus 1.3.6.1.4.1.4458.1000.1.3.2.1.7 Integer RO winlink1000OduEthernetIfFailAction 1.3.6.1.4.1.4458.1000.1.3.2.1.8 Integer RW Failure action of the interface. winlink1000OduEthernetNumOfPorts 1.3.6.1.4.1.4458.1000.1.3.3 Integer RO Current operational state of the interface. Number of ODU network interfaces. winlink1000OduBridgeBasePortTable N/A ODU Bridge Ports table. winlink1000OduBridgeBasePortEntry N/A ODU Bridge Ports table entry. winlink1000OduBridgeBasePortIndex RO ODU Bridge Port Number. winlink1000OduBridgeBaseIfIndex RO IfIndex corresponding to ODU Bridge port. winlink1000OduBridgeTpMode 1.3.6.1.4.1.4458.1000.1.4.4.101 Integer RW ODU bridge mode. A change is effective after reset. Valid values: hubMode (0) bridgeMode (1). winlink1000OduBridgeTpPortTable N/A ODU Transparent Bridge Ports table. winlink1000OduBridgeTpPortEntry N/A ODU Transparent Bridge Ports table entry. winlink1000OduBridgeTpPortIndex RO ODU Transparent Bridge Port Number. winlink1000OduBridgeTpPortInFrames 1.3.6.1.4.1.4458.1000.1.4.4.3.1.3 Counter RO Number of frames received by this port. winlink1000OduBridgeTpPortOutFrames 1.3.6.1.4.1.4458.1000.1.4.4.3.1.4 Counter RO Number of frames transmitted by this port. winlink1000OduBridgeTpPortInBytes 1.3.6.1.4.1.4458.1000.1.4.4.3.1.10 Counter RO Number of bytes received by this port. winlink1000OduBridgeTpPortOutBytes 1.3.6.1.4.1.4458.1000.1.4.4.3.1.10 Counter RO Number of bytes transmitted by this port. winlink1000OduAirFreq 1.3.6.1.4.1.4458.1000.1.5.1 Integer RW Installation Center Frequency. Valid values are product dependent. A change is effective after link re-synchronization. winlink1000OduAirDesiredRate 1.3.6.1.4.1.4458.1000.1.5.2 Integer RW Deprecated parameter actual behavior is readonly. Required Air Rate. For Channel Bandwidth of 20 10 5 MHz divide the value by 1 2 4 respectively. winlink1000OduAirSSID 1.3.6.1.4.1.4458.1000.1.5.3 DisplayString RW Reserved for the Manager application provided with the product. winlink1000OduAirTxPower 1.3.6.1.4.1.4458.1000.1.5.4 Integer RW Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation. The min and max values are product specific. A change is effective immediately. winlink1000OduAirSesState 1.3.6.1.4.1.4458.1000.1.5.5 Integer RO Current Link State. The value is active (3) during normal operation. winlink1000OduAirMstrSlv 1.3.6.1.4.1.4458.1000.1.5.6 Integer RO This parameter indicates if the device was automatically selected into the radio link master or slave. The value is undefined if there is no link. winlink1000OduAirResync 1.3.6.1.4.1.4458.1000.1.5.8 Integer RW Setting this parameter to 1 will cause the link to restart the synchronization process. winlink1000OduAirRxPower 1.3.6.1.4.1.4458.1000.1.5.9.1 Integer RO Received Signal Strength in dBm. winlink1000OduAirTotalFrames 1.3.6.1.4.1.4458.1000.1.5.9.2 Counter RO Total Number of received radio frames. winlink1000OduAirBadFrames 1.3.6.1.4.1.4458.1000.1.5.9.3 Counter RO Total number of received radio frames with CRC error. winlink1000OduAirCurrentRate 1.3.6.1.4.1.4458.1000.1.5.9.4 Integer RO Deprecated parameter. Actual rate of the air interface in Mbps. For Channel Bandwidth of 20 10 5 MHz divide the value by 1 2 4 respectively. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 F-7 MIB Parameters Appendix F Table F-2: Private MIB Parameters (Sheet 4 of 14) OID Type Access Name Description winlink1000OduAirCurrentRateIdx 1.3.6.1.4.1.4458.1000.1.5.9.5 Integer RO winlink1000OduAirTxPower36 1.3.6.1.4.1.4458.1000.1.5.10 Integer RW Deprecated parameter. Actual behavior is readonly. Index of current air rate. winlink1000OduAirTxPower48 1.3.6.1.4.1.4458.1000.1.5.11 Integer RW Deprecated parameter. Actual behavior is readonly. winlink1000OduAirCurrentTxPower 1.3.6.1.4.1.4458.1000.1.5.12 Integer RO Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation. winlink1000OduAirMinFrequency 1.3.6.1.4.1.4458.1000.1.5.13 Integer RO Minimum center frequency in MHz. winlink1000OduAirMaxFrequency 1.3.6.1.4.1.4458.1000.1.5.14 Integer RO Maximum center frequency in MHz. winlink1000OduAirFreqResolution 1.3.6.1.4.1.4458.1000.1.5.15 Integer RO Center Frequency resolution. Measured in MHz if value < 100 otherwise in KHz. winlink1000OduAirCurrentFreq 1.3.6.1.4.1.4458.1000.1.5.16 Integer RO Current Center Frequency. Measured in MHz if center frequency resolution value < 100 otherwise in KHz. winlink1000OduAirNumberOfChannels 1.3.6.1.4.1.4458.1000.1.5.17 Integer RO Number of channels that can be used. winlink1000OduAirChannelsTable N/A Table of channels used by automatic channels selection (ACS). winlink1000OduAirChannelsEntry N/A ACS channels table entry. winlink1000OduAirChannelsIndex 1.3.6.1.4.1.4458.1000.1.5.18.1.1 Integer RO Channel Index. winlink1000OduAirChannelsFrequency 1.3.6.1.4.1.4458.1000.1.5.18.1.2 Integer RO Channel frequency in MHz. winlink1000OduAirChannelsOperState 1.3.6.1.4.1.4458.1000.1.5.18.1.3 Integer RW Channel state. Can be set by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. A change is effective after link re-synchronization. Valid values: disabled (0) enabled (1). winlink1000OduAirChannelsAvail 1.3.6.1.4.1.4458.1000.1.5.18.1.4 Integer RO Channel state. Product specific and cannot be changed by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. Valid values: disabled (0) enabled (1). winlink1000OduAirDfsState 1.3.6.1.4.1.4458.1000.1.5.19 Integer RO Radar detection state. Valid values: disabled (0) enabled (1). winlink1000OduAirAutoChannelSelection 1.3.6.1.4.1.4458.1000.1.5.20 State Integer RO Deprecated parameter. Indicating Automatic Channel Selection availability at current channel bandwidth. Valid values: disabled (0) enabled (1). winlink1000OduAirEnableTxPower 1.3.6.1.4.1.4458.1000.1.5.21 Integer RO Indicating Transmit power configuration enabled or disabled. winlink1000OduAirMinTxPower 1.3.6.1.4.1.4458.1000.1.5.22 Integer RO Minimum Transmit power in dBm. winlink1000OduAirMaxTxPowerTable N/A Table of Maximum transmit power per air rate in dBm. winlink1000OduAirMaxTxPowerEntry N/A Maximum Transmit power table entry. winlink1000OduAirMaxTxPowerIndex 1.3.6.1.4.1.4458.1000.1.5.23.1.1 Integer RO Air interface rate index. winlink1000OduAirMaxTxPower 1.3.6.1.4.1.4458.1000.1.5.23.1.2 Integer RO Maximum Transmit power in dBm. winlink1000OduAirChannelBandwidth 1.3.6.1.4.1.4458.1000.1.5.24 Integer RW Channel bandwidth in KHz. A change is effective after reset. winlink1000OduAirChannelBWTable N/A Channel Bandwidths table. winlink1000OduAirChannelBWEntry N/A Channel Bandwidth table entry. winlink1000OduAirChannelBWIndex 1.3.6.1.4.1.4458.1000.1.5.25.1.1 Integer RO Channel Bandwidth index. winlink1000OduAirChannelBWAvail 1.3.6.1.4.1.4458.1000.1.5.25.1.2 Integer RO Channel Bandwidth availability product specific. Options are: Not supported supported with manual channel selection supported with Automatic Channel Selection. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 F-8 MIB Parameters Appendix F Table F-2: Private MIB Parameters (Sheet 5 of 14) OID Type winlink1000OduAirRFD 1.3.6.1.4.1.4458.1000.1.5.26 Integer Access Name RO Description Current radio frame duration in microseconds. winlink1000OduAirRatesTable N/A Air Rate indexes table for current channel bandwidth. winlink1000OduAirRatesEntry N/A Air Rate indexes table entry. winlink1000OduAirRatesIndex 1.3.6.1.4.1.4458.1000.1.5.27.1.1 Integer RO Air Rate index. winlink1000OduAirRatesAvail 1.3.6.1.4.1.4458.1000.1.5.27.1.2 Integer RO Air Rate availability depending on air interface conditions. winlink1000OduAirDesiredRateIdx 1.3.6.1.4.1.4458.1000.1.5.28 Integer RW Required Air Rate index. 0 reserved for Adaptive Rate. A change is effective immediately after Set operation to the master side while the link is up. winlink1000OduAirLinkDistance 1.3.6.1.4.1.4458.1000.1.5.29 Integer RO Link distance in meters. A value of -1 indicates an illegal value and is also used when a link is not established. winlink1000OduAirLinkWorkingMode 1.3.6.1.4.1.4458.1000.1.5.30 Integer RO Link working mode as a result of comparing versions of both sides of the link. Possible modes are: Unknown - no link Normal - versions on both sides are identical with full compatibility with restricted compatibility or versions on both sides are different with software upgrade or versions incompatibility. winlink1000OduAirMajorLinkIfVersion 1.3.6.1.4.1.4458.1000.1.5.31 Integer RO Major link interface version winlink1000OduAirMinorLinkIfVersion 1.3.6.1.4.1.4458.1000.1.5.32 Integer RO Minor link interface version winlink1000OduAirHssDesiredOpState 1.3.6.1.4.1.4458.1000.1.5.40.1 Integer RW Required Hub Site Synchronization operating state. winlink1000OduAirHssCurrentOpState 1.3.6.1.4.1.4458.1000.1.5.40.2 Integer RO Current Hub Site Synchronization operating state. winlink1000OduAirHssSyncStatus 1.3.6.1.4.1.4458.1000.1.5.40.3 Integer RO Hub Site Synchronization sync status. winlink1000OduAirHssExtPulseStatus 1.3.6.1.4.1.4458.1000.1.5.40.4 Integer RO Hub Site Synchronization external pulse detection status. winlink1000OduAirHssExtPulseType 1.3.6.1.4.1.4458.1000.1.5.40.5 Integer RO Hub Site Synchronization external pulse type. winlink1000OduAirHssDesiredExtPulseT ype 1.3.6.1.4.1.4458.1000.1.5.40.6 Integer RW Hub Site Synchronization required external pulse type. Valid values for read write: {typeA(2) typeB(3) typeC(4) typeD(5)}. Valid value for read only: {notApplicable(1)}. winlink1000OduAirHssRfpTable N/A ODU Radio Frame Patterns (RFP) Table. winlink1000OduAirHssRfpEntry N/A ODU RFP Table entry. winlink1000OduAirHssRfpIndex 1.3.6.1.4.1.4458.1000.1.5.40.7.1.1 Integer RO ODU RFP Table index. The index represent the Radio Frame Pattern: typeA(2) typeB(3) typeC(4) typeD(5). winlink1000OduAirHssRfpEthChannelB W5MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.2 Integer RO Represents the compatibility of Ethernet service under Channel BW of 5MHz in the specific Radio Frame Pattern. winlink1000OduAirHssRfpTdmChannelB W5MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.3 Integer RO Represents the compatibility of TDM service under Channel BW of 5MHz in the specific Radio Frame Pattern. winlink1000OduAirHssRfpEthChannelB W10MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.4 Integer RO Represents the compatibility of Ethernet service under Channel BW of 10MHz in the specific Radio Frame Pattern. winlink1000OduAirHssRfpTdmChannelB W10MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.5 Integer RO Represents the compatibility of TDM service under Channel BW of 10MHz in the specific Radio Frame Pattern. winlink1000OduAirHssRfpEthChannelB W20MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.6 Integer RO Represents the compatibility of Ethernet service under Channel BW of 20MHz in the specific Radio Frame Pattern. winlink1000OduAirHssRfpTdmChannelB W20MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.7 Integer RO Represents the compatibility of TDM service under Channel BW of 20MHz in the specific Radio Frame Pattern. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 F-9 MIB Parameters Appendix F Table F-2: Private MIB Parameters (Sheet 6 of 14) Access Name OID Type Description winlink1000OduAirLockRemote 1.3.6.1.4.1.4458.1000.1.5.41 Integer RW This parameter enables locking the link with a specific ODU. The following values can be set: Unlock (default) - The ODU is not locked on a specific remote ODU. Unlock can only be performed when the link is not connected. Lock The ODU is locked on a specific remote ODU. Lock can only be performed when the link is active. winlink1000OduAirAntennaGain 1.3.6.1.4.1.4458.1000.1.5.42 Integer RW Current Antenna Gain in 0.1 dBi resolution. User defined value in case of external antenna. Legal range: MinAntennaGain - Alarm. externalAlarmInPort2Alarm 106 major The trap is sent every time an alarm occurs in the External Alarm Input of port #2. Contains a single parameter which is its description: 1 Description: External Alarm 2 - - Alarm. bitFailedAlarm 107 critical The trap is sent in case there is no way to recover from the situation. Contains two parameters: 1 - Description: ODU power up built in test failed. Error code is: %n. 2 - %n number. wrongConfigurationLoadedAlarm 108 major The trap is sent in case there is a way to recover from the situation. Contains two parameters: 1 - Description: Wrong configuration loaded. Error code is: %n. 2 - %n number. lanPort1DisconnectedAlarm 109 major Indicates the LAN port 1 status changed to disconnected. Contains a single parameter which is its description: 1 - Description: LAN port 1 status changed to disconnected. lanPort2DisconnectedAlarm 110 major Indicates the LAN port 2 status changed to disconnected. Contains a single parameter which is its description: 1 - Description: LAN port 2 status changed to disconnected. mngPortDisconnectedAlarm 111 major Indicates the management port status changed to disconnected. Contains a single parameter which is its description: 1 - Description: Management port status changed to disconnected. externalAlarmInPort3Alarm 112 major The trap is sent every time an alarm occurs in the External Alarm Input of port #3. Contains a single parameter which is its description: 1 Description: External Alarm 3 - - Alarm. externalAlarmInPort4Alarm 113 major The trap is sent every time an alarm occurs in the External Alarm Input of port #4. Contains a single parameter which is its description: 1 Description: External Alarm 4 - - Alarm. swVersionsMismatchFullCompatibilityAlarm 114 warning The trap is sent in case SW versions mismatch with full link functionality. Contains a single parameter which is its description: 1 - Description: Software versions mismatch - full link functionality swVersionsMismatchRestrictedCompatibilityAlarm 115 minor The trap is sent in case SW versions mismatch with restricted link functionality. Contains a single parameter which is its description: 1 Description: Software versions mismatch - restricted link functionality swVersionsMismatchSoftwareUpgradeRequired 116 major The trap is sent in case SW versions mismatch and SW upgrade is required. Contains a single parameter which is its description: 1 Description: Software versions mismatch - Software upgrade required swVersionsIncompatible 117 critical The trap is sent in case SW versions are incompatible. Contains a single parameter which is its description: 1 - Description: SW Versions incompatible tdmBackupAlarm 121 major Indicates that the TDM backup link was activated. Contains a single parameter, which is its description: 1 - Description: TDM backup alarm backup link was activated. linkLockUnautorizedRemoteODU 122 major Indicates that the remote ODU is unautorized. Contains a single parameter which is its description: 1 - Description: Unauthorized remote ODU connection rejected. linkLockUnautorizedODU 123 major Indicates that the ODU is unautorized. Contains a single parameter which is its description: 1 - Description: Unauthorized ODU connection rejected. tdmServiceClear 200 normal Indicates that TDM Service fault is cleared. Contains a single parameter, which is its description: 1 - Description: TDM Service - Normal. ethServiceOpened 201 normal Indicates that Ethernet Service has been opened. Contains a single parameter,3 which is its description: 1 - Description: Ethernet Service has been opened. encryptionClear 203 normal Indicates that encryption is OK. Contains a single parameter which is its description: 1 - Description: Encryption Status - Normal. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 F-20 RADWIN Manager Traps Appendix F Table F-3: MIB Traps (Sheet 4 of 4) Name ID Severity Description changeLinkPasswordClear 204 normal Indicates that the Link Password was changed successfully. Contains a single parameter which is its description: 1 - Description: Link Password has been changed at/on: %s. %s - Is the Local Site name or Remote Site name or both sides of the Link. externalAlarmInPort1Clear 204 normal This Trap is sent every time an External Alarm Input fault of port # 1 is cleared. Contains a single parameter which is its description: 1 Description: External Alarm 1 - - Alarm Cleared. externalAlarmInPort2Clear 206 normal This Trap is sent every time an External Alarm Input fault of port # 2 is cleared. Contains a single parameter which is its description: 1 Description: External Alarm 2 - - Alarm Cleared. lanPort1Clear 209 normal Indicates the LAN port 1 status changed to connected. Contains two parameters: 1 - Description: LAN port 1 status changed to connected %s. 2 - %s Is the Eth. mode (speed & duplex). lanPort2Clear 210 normal Indicates the LAN port 2 status changed to connected. Contains two parameters: 1 - Description: LAN port 2 status changed to connected %s. 2 - %s Is the Eth. mode (speed & duplex). mngPort2Clear 211 normal Indicates the management port status changed to connected. Contains two parameters: 1 - Description: Management port status changed to connected - %s. 2 - %s Is the Eth. mode (speed & duplex). externalAlarmInPort3Clear 211 normal This Trap is sent every time an External Alarm Input fault of port # 3 is cleared. Contains a single parameter which is its description: 1 Description: External Alarm 3 - - Alarm Cleared. externalAlarmInPort4Clear 213 normal This Trap is sent every time an External Alarm Input fault of port # 4 is cleared. Contains a single parameter which is its description: 1 Description: External Alarm 4 - - Alarm Cleared. swVersionsMatchFullCompatibilityClear 214 normal The trap is sent in case SW versions match. Contains a single parameter which is its description: 1 - Description: Software Versions compatible swVersionsMatchRestrictedCompatibilityClear 215 normal The trap is sent in case SW versions match and link functionality is not restricted. Contains a single parameter which is its description: 1 Description: Software Versions compatible swVersionsMatchSoftwareUpgradeRequiredClear 216 normal The trap is sent in case SW versions match and SW upgrade is successful. Contains a single parameter which is its description: 1 Description: Software Versions compatible swVersionsCompatibleClear 217 normal The trap is sent in case SW versions compatible Contains a single parameter which is its description: 1 - Description: Software Versions compatible tdmBackupClear 221 normal linkLockAutorizedODU 223 normal Indicates that the ODU is autorized. Contains a single parameter which is its description: 1 - Description: Authorized ODU connection permitted. linkAuthenticationDisabled 224 normal Indicates that the Link Lock is disabled. Contains a single parameter which is its description: 1 - Description: Link Authentication has been disabled RADWIN Manager Traps The RADWIN Manager application issues traps to indicate various events. These traps are shown in the RADWIN Managerr Events Log. A list of Trap Messages as displayed by the RADWIN Manager is shown in table 7-5. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 F-21 Appendix G External Alarms Specification External Alarms Specification The IDU-C supports external input and output alarms through a standard DB25 pin female connector. Input alarms The input alarms are raised by events from external equipment, such as a fire warning, door open or air conditioner failure. Output alarms Output alarms are generated through dry contact relays to indicate various system events according to the following table. An alarm is raised if at least one of the conditions is met. Table G-1: Output Alarms Pinout Alarm Description Alarm On Conditions Alarm Off Condition Output 1 Air interface Alarm • • • Link is down Link in installation mode Link authentication problem Output 2 Equipment Alarm • • • Both ODU and IDU are in Built in Test (BIT) error operational state No connection to the ODU Incompatible software Output 3 Service Alarm at Site B N/A Permanently off Output 4 Power Failure at Site B Link Loss due to Power Failure at Site B Link is up or down without power failure indication within the last two seconds RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 Link is up G-1 Appendix H Combo Configuration Tool What is the Combo Configuration Tool? The RADWIN 1000/2000/5000 is supplied preconfigured to a default frequency band and regulation. The user may however, reconfigure it to use any one of the supported frequency bands shown in the following example: Product Default Band FCC/IC 5.8 GHz FCC/IC 5.3 GHz 2050 FCC/IC 5.4 GHz FCC/IC 4.9 GHz FCC/IC 2.4 GHz The Combo Configuration Tool is a software utility supplied by RADWIN to change the link frequency band. It runs as familiar Windows Wizard. This appendix will walk you through the Wizard. It also provides help for common problems encountered during the configuration. Who may use the Combo Configuration Tool The Combo Configuration Tool is a password protected utility intended for the use of RADWIN accredited personnel at the user’s site, RADWIN Customer Support Engineers or Professional Installers conversant with FCC requirements. Caveat to the use of the Combo Configuration Tool It is the user’s responsibility to operate the system according to local regulations and to acquire the relevant permits or licenses for the frequency band selected, if applicable. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-1 Prerequisites to using the Combo Configuration Tool Appendix H Prerequisites to using the Combo Configuration Tool To use the Tool, you need a PC running Windows 2000 or Windows XP Pro to be connected to the RADWIN 1000/2000/5000 link. Operating the Combo Configuration Tool The tool is supplied as an executable called ComboConfigurationTool.exe. It should be copied to a convenient directory on a hard disk from where it can be run from a command line, or placed on the desktop and opened with a double click. The Combo Configuration Tool is a Wizard, which guides you through the process of changing the frequency band. Before using the Combo Configuration Tool Before starting: Obtain the IP address of both the local ODU and remote ODUs of the link Make a note of the correct required frequency band If the link uses external antennas, ensure that they support your required frequency band Also, note that 1. The procedure below must be carried out for both ODUs in the link. 2. Changing the frequency band may affect the available Link Budget and system performance. Using the Combo Configuration Tool  To change the link frequency band: 1. Open the Tool from a command line or double clicking it on the desktop. The following Welcome screen appears: RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-2 Using the Combo Configuration Tool Appendix H 2. Click Next. The window below is displayed: 3. Enter the ODU IP address and password. 4. Click Next. The following progress panel is displayed: RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-3 Using the Combo Configuration Tool Appendix H Upon completion the following screen is displayed: The checked item is the currently configured frequency band. 5. Check the box with the required frequency band. If you do not see the required frequency band in the above window, click Cancel and consult RADWIN Customer Support. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-4 Using the Combo Configuration Tool Appendix H 6. Otherwise, click Next. The following window is displayed: 7. If the legal notice is acceptable, click the “I accept” radio button, and then click Next. Two successive progress panels are displayed. The configuration may take several minutes. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-5 If you receive an error message Appendix H Upon successful completion of the configuration process, the following termination window is displayed: 8. Click Finish to exit the Wizard as shown. 9. Repeat the whole process for the second ODU in the link. If you receive an error message The last stage above may terminate unsuccessfully due to an error. Error messages are posted to a window like this: RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-6 If you receive an error message Appendix H The following table sets out possible errors: Error Number Error Text Message (nn) Common message preamble: The Configure procedure has failed with the following error: ERROR nn occurred: 120 Failed to communicate with the ODU. Please verify the existence of a stable IP connection and try again. 940 Product is not identified. 1040 The ODU is not a Combo product. 1020 A configuration problem detected. Aborting. The only items requiring explanation are errors 940 and 1020. Error 940 may arise as a result of an ODU firmware problem. Error 1020 will appear for any reason not caught by the other entries in the table. In all such cases, you should consult with RADWIN Customer Support. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 H-7 Appendix I Regional Notice: French Canadian Procédures de sécurité Généralités Avant de manipuler du matériel connecté à des lignes électriques ou de télécommunications, il est conseillé de se défaire de bijoux ou de tout autre objet métallique qui pourrait entrer en contact avec les éléments sous tension. Mise à la terre Tous les produits RADWIN doivent être mis à la terre pendant l'usage courant. La mise à la terre est assurée en reliant la fiche d'alimentation à une prise de courant avec une protection de terre. En outre: • La cosse de masse sur l'IDU-C doit être constamment connectée à la protection de terre, par un câble de diamètre de 18 AWG ou plus. Le matériel monté sur rack doit être installé seulement sur des racks ou armoires reliés à la terre • Une ODU doit mise à la terre par un câble de diamètre de 12 AWG ou plus • Il ne doit pas y avoir de fusibles ou d'interrupteurs sur la connection à la terre De plus: • Il faut toujours connecter la terre en premier et la déconnecter en dernier • Il ne faut jamais connecter les câbles de télécommunication à du matériel non à la terre • Il faut s'assurer que tous les autres câbles sont déconnectés avant de déconnecter la terre RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 I-1 Protection contre la foudre Appendix I Protection contre la foudre L'utilisation de dispositifs de protection contre la foudre dépend des exigences réglementaires et de l'utilisateur final. Toutes les unités extérieures RADWIN sont conçues avec des circuits de limitation de surtension afin de minimiser les risques de dommages dus à la foudre. RADWIN conseille l'utilisation d'un dispositif de parafoudre supplémentaire afin de protéger le matériel de coups de foudre proches. Matériel supplémentaire requis L'équipement requis pour l'installation du matériel est le suivant: • Pince à sertir RJ-45 (si un câble pré-assemblé ODU/IDU n'est pas utilisé) • Perceuse (pour le montage sur mur seulement) • Câbles de terre IDU et ODU • Clef 13 mm (½) • Câble ODU - IDU si non commandé (type extérieur, CAT-5e, 4 paires torsadées, 24 AWG) • Colliers de serrage • Ordinateur portable avec Windows 2000 ou Windows XP. Précautions de sécurité pendant le montage de ODU Avant de connecter un câble à l'ODU, la borne protectrice de masse (visse) de l'ODU doit être connectée à un conducteur externe protecteur ou à un pylône relié à la terre. Il ne doit pas y avoir de fusibles ou d'interrupteurs sur la connection à la terre. Seulement un personnel qualifié utilisant l'équipement de sécurité approprié doit pouvoir monter sur le pylône d'antenne. De même, l'installation ou le démontage de ODU ou de pylônes doit être effectuée seulement par des professionnels ayant suivi une formation.  Pour monter l'ODU: 1. Vérifier que les supports de fixation de l'ODU sont correctement mis à la terre. 2. Monter l'unité ODU sur le pylône ou sur le mur; se référer à la Installation sur pylône et mur au dessous. 3. Connecter la câble de terre au point de châssis sur l'ODU. 4. Relier le câble ODU-IDU au connecteur ODU RJ-45. 5. Visser les presses-étoupe de câbles pour assurer le scellement hermétique des unités ODU. 6. Attacherlecâbleaupylôneouauxsupportsenutilisantdescolliersclassés UV. 7. Répéter la procédure sur le site distant. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 I-2 Connecter la terre à IDU-C Appendix I Ne pas se placer en face d'une ODU sous tension. Prudence Connecter la terre à IDU-C Connecter un câble de terre de 18 AWG à la borne de masse de l'appareil. L'appareil doit être constamment connecté à la terre. Prudence • Les appareils sont prévus pour être installés par un personnel de service. • Les appareils doivent être connectés à une prise de courant avec une protection de terre. • Le courant CC du IDU-C doit être fourni par l'intermédiaire d'un disjoncteur bipolaire et le diamètre du câble doit être de 14 mm avec un conduit de 16 mm. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 I-3 Installation sur pylône et mur Appendix I Installation sur pylône et mur L' ODU ou l'O-PoE peuvent être montés sur un pylône ou un mur. Contenu du kit de montage ODU Le kit de montage ODU comprend les pièces suivantes: • une grande clame (voir figure I-1) • une petite clame (voir figure I-2) • un bras (voir figure I-3) • quatre visses hex tête M8x40 • deux visses hex tête M8x70 • quatre rondelles plates M8 • trois rondelles élastiques M8 • deux écrous M8. Figure I-1: grande clame Figure I-2: petite clame RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 Figure I-3: bras I-4 Montage sur un pylône Appendix I Montage sur un pylône Figure I-4: Montage sur un pylône RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 I-5 Montage sur un mur Appendix I Montage sur un mur Figure I-5: Montage sur un mur RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 I-6 Montage d'une antenne externe Appendix I Montage d'une antenne externe L'antenne externe optionnelle peut être montée sur un pylône. Contenu du kit de montage d'une antenne externe Le kit de montage d'une antenne externe comprend les pièces suivantes • Douze rondelles plates • Huit rondelles élastiques • Huit écrous hex • Quatre boulons • Un support en U • Un support à pivotement • Deux courroies de fixation en métal  Pour installer une antenne externe sur un pylône: 1. Attacher le support en U à l'arrière de l'antenne en utilisant quatre rondelles plates, quatre rondelles élastiques et quatre écrous hex. 2. Attacher le support à pivotement au support en U en utilisant huit rondelles plates, quatre rondelles élastiques, quatre écrous hex et quatre boulons. 3. Passer les deux courroies de fixation par les fentes verticales dans le support à pivotement. 4. Attacher l'antenne au pylône en utilisant les deux courroies de fixation . Ajuster l'inclinaison nécessaire en utilisant l'échelle angulaire et serrer tous les boulons et écrous à la position requise. RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 I-7 Index Index AAR 1-4 ACS 4-17, 6-20, F-8, F-8 aging time, ODU Bridge Mode 6-10 Air Interface 1-12, 1-12 Technical Specifications, general A-1 Alarms 7-9 Active summary 7-14 Connector B-3 External , specification G-1 Antennas Align with beeper 3-13 Aligning 3-13 bipolar 3-13 Buzzer signals 3-14 monopolar 3-14 Cable, grounding E-1 Connecting 3-13 Described 1-10 External Mounting 3-7 Package Contents 3-5 External, Mounting C-3 Flat panel 1-11 Parabolic Dish 1-12 Settings 4-19, 5-18 types 1-8 Applications Broadband Access 1-2 IP Backhaul 1-2 Private Networks 1-3 WiMAX 1-2 Automatic Adaptive Rate, see AAR 1-4 Automatic Channel Selection, see ACS Automatic Repeat Request 1-4 backup configuration file ODU replacement Beeper mute muting and restoring restore Bridge mode,Telnet commands Buzzer, see Beeper Changing link password 4-16 Channel, selecting 4-17, 5-12 Community Strings 6-16 Changing Editing 6-15 Factory Default 6-14, F-2 Forgotten passwords 6-16 MIB F-2 passwords 4-4 Read-Only 6-14 Read-Write 6-14 Trap 6-14 Configuration Parameters 6-3 Configuring Advanced 6-2, 6-9, 6-11, 6-12, 6-18 Air Interface 6-2 Air interface 5-1 Bridge mode 6-1 Community values. 6-1 contact person 6-2 Date and Time 6-2 Ethernet mode 6-1 Frequency channel 5-1 Security 6-2 Service parameters 5-1 System 6-2 System parameters 5-1 Transmit power 6-1 View Inventory 6-2 Connecting user equipment 4-17, 5-12 Customer Support 7-17 Date and time, setting Default log on password 6-2 7-16 6-17 6-3 6-17 6-21 6-2, 6-7 4-4 Events color codes log priority RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 7-12 7-2, 7-4 7-13 Index 1 F Factory Defaults 6-14, F-2 Reset to 6-19 Factory Setup Restoring 7-17 FEC 4-21, 4-22, A-4, A-4 Forward Error Correction, see FEC Gateway Telnet display 6-2 6-20 IDU Aging time 6-10 aging time, ODU Bridge Mode 6-10 Connecting to ODU 3-12 described 1-8 IDU-C Alarm Connector B-3 Connectors B-4 Front panel 1-9 Described 3-10 LEDs 3-10, 3-11, 4-2 Mounting 3-8 Power connections 3-11, 3-12 Package Contents 3-4 Products 1-8 Indoor Unit, see IDU Installation Menu and Toolbar Functionality 4-10 Post Configuration main window 5-22 Post Installation main window 4-27 see Link, Installation Installation Mode 6-3, 6-3, 6-12 Inventory 6-16 Displaying 6-12 IP address 6-2 Telnet display 6-20 Key Features of Radio Link Advanced Air Interface Capacity Combo Frequency Products Installation and management Range performance Security Spectral Efficiency Transmission (Tx) power 1-4 1-3 1-4 1-4 1-4 1-5 1-3 1-4 LBC Browser warnings Calculations Climactic C Factors 7-4 D-6 D-2 D-10 D-1 described Fresnel Zone, described D-13 Internal data D-1 Running D-3 User input D-1 Lightning and Grounding Guidelines E-1 Link Budget Calculator, see LBC Configuration 5-1 Overview 5-10 Step 1 - Start Wizard 5-11 Step 2- System Parameters 5-11 Step 3 - Channel Settings 5-12 Step 4 - Tx Power and Antenna Settings 5-18 Step 5 - Services 5-20 Step 6 - Summary and exit 5-21 default frequency 4-18 default Settings 4-9 Information 7-1 Air Interface Thresholds BBER Threshold 7-9 RSL Threshold 7-9 Air Interface Thresholds, setting 7-9 Alarms Active summary 7-14 Error detection and 7-14 output 7-15 saved 7-14 Compatibility 7-3 Trap messages 7-3 Events Log 7-4 Events log Events references trap background color 7-13 default colors 7-13 foreground color 7-12 Preferences 7-12 saving 7-13 Monitor log 7-4, 7-4 saving 7-4 Online Help 7-17 Performance data, explained 7-8 Performance monitoring 7-4 Performance Reports 7-5 Remote Power Fail Indication 7-15 “Dying-Gasp” circuit 7-15 Troubleshooting 7-16 Installation 4-7 ODU Mast and Wall C-1 Overview 4-13 Step 1 - Start Wizard 4-14 Step 2 - System Parameters 4-14 Step 3 - Channel Settings 4-17 Step 4 - Tx Power and Antenna Settings RADWIN 1000/2000/5000 User ManualVersion2.5.30p3 Index 2 4-19 Background 4-20 Step 5 - Services 4-25 Step 6 - Summary and Exit 4-26 Link ID 4-9, 4-15, 6-20, 7-16, 7-16, 7-17 Login 4-3 Login Errors Incorrect IP Address 4-6 Incorrect password 4-6 Unsupported Device 4-5 Login showing Community Options 4-5 Manager Software 4-2 Name 4-15 Password 1-5, 7-17 changing 4-16 Post Configuration main window 5-22 Post Installation main window 4-27 Reinstalling/Realigning 7-3 Site names 4-15 Link Budget Calculator, see LBC 7-4 Link ID 4-9, 4-15, 6-20, 7-16, 7-16, 7-17 Link Site Planning 2-1 Survey 2-1 Stage 1 - Preliminary Survey 2-2 Stage 2 - Physical Survey 2-3 Additional Indoor Site Requirements 2-4 Additional Outdoor Site Requirements 2-4 Stage 3 - RF Survey 2-4 Login Errors Incorrect IP Address 4-6 Incorrect password 4-6 Unsupported Device 4-5 Management Addresses and trap addresses Configuring the Site Screen, Telnet Manager Software Change log on password Events Log Installing Main window Details pane Main menu Toolbar main window Monitor pane Ethernet Service Radio Interface, Radio signal strength Off-line functionality 6-4 6-1 6-2 6-22 4-7 5-8 4-1 5-1 5-6 5-3 5-2 4-5 5-7 5-7 5-7 5-7 4-6 5-9 Status Bar Manual Chapters by Audience 1-14 Conventions 1-16 Terminology 1-14 MIB About F-1 Community String F-2 Interface API F-1 Parameters F-4 Private F-2 Private Parameters F-5 Reference F-1 Supported Variables from the RFC 1213 F-4 Terminology F-1 Traps F-18 Parameters F-18 ODU Bridge Mode aging time Connectorized described form factors Installation, Mast and Wall Integrated Antenna Mounting Kit Package Contents Products Replacing With integrated antenna 1-7 6-10 1-6, 1-7 1-6 1-7 C-1 1-6, 1-7 C-1 3-2 1-8 7-16 1-10 Package, contents of 3-2 Password Community 4-4, 4-4 Default 4-4 default log on 4-4 Link 1-5, 7-17 PC, Minimum Requirements 4-1 Performance Monitor 7-2 Performance Monitoring, set time interval 7-4 PoE Described 1-9 PoE device, see PoE Power over Ethernet, see PoE Protection External Lightning Surge Suppressors E-3 Grounding Antenna cable E-1 IDUs E-2 ODUs E-2 Internal ESD Protection circuits E-7 RADWIN 1000/2000/5000 User ManualVersion2.5.30p3 Index 3 R Radio Link Accessories 1-13 Additional Tools and Materials Required 3-5 Connecting user equipment 3-12 Described 1-5 Documentation set 1-13 Hardware Installation External Antennas 3-7 Indoor 3-8 Lightning protection 3-7 Mounting U 3-8 ODU 3-6 Outdoor 3-6 Outdoor connections 3-8 Sequence 3-5 Package Contents 3-2 IDU 3-4 ODU 3-2 Package contents External Antennas 3-5 Transmission rates 4-22 Radio Outdoor Unit, see ODU Replacing an ODU 7-16 restore configuration file 6-2 Safety Practices 3-1 Grounding 3-1 Preventing overexposure to RF energy 3-1 Selecting channel 4-17, 5-12 Site Configuration Configuration Files 6-18 backup to 6-18 Configuration files restore from 6-19 Configuration with Telnet 6-20 Dialog Change Tx Power 6-4 Ethernet Properties 6-9 Configuring Bridge 6-9 Maximum information rate 6-12 Ports Mode 6-11 Ethernet PropertiesIDU Aging time 610 Functions 6-2 Inventory 6-12 Menu bar 6-2 Setting the date and time 6-7 View Air Iinterface details 6-3 VLAN Settings 6-5 Lost or forgotten VLAN ID 6-7 Priority number 6-6 VLAN ID 6-6 External Alarm Inputs 6-17 6-19 Reset site Reset site to factory defaults 6-19 Reset site, preserve current configuration 6-19 Security Features 6-13 Community Strings 6-14 Editing 6-15 Forgotten paswwords 6-16 Initial log on defaults 6-15 Default Gateway 6-5 IP address 6-5, 6-5 Trap Destination 6-5 Technical Specifications Air Interface Air Interface, general Configuration EMC Environmental Ethernet Interface Management Mechanical Power Radio Safety Trap messages typical installation A-5 A-1 A-1 A-5 A-5 A-4 A-5 A-5 A-5 A-2 A-5 7-3 3-5 User equipment, connecting 4-17, 5-12 Wiring Specifications Alarm Connector IDU-C Connectors IDU-C User Port LAN Ports ODU-IDU Cable Ports LAN User Port Connectors RADWIN 1000/2000/5000 User ManualVersion2.5.30p3 B-1 B-3 B-4 B-1 B-1 B-1 B-1 B-1 Index 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : DAF
Create Date                     : 2011:04:10 12:04:54Z
Modify Date                     : 2011:04:10 14:28:05+03:00
Subject                         : 1.790 User Manual
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : FrameMaker 10.0
Metadata Date                   : 2011:04:10 14:28:05+03:00
Format                          : application/pdf
Title                           : STW
Creator                         : DAF
Description                     : 1.790 User Manual
Producer                        : Acrobat Distiller 10.0.1 (Windows)
Document ID                     : uuid:5bc54c0e-8ca4-4e13-84f1-0bb78d6a7bdb
Instance ID                     : uuid:1871d377-c4eb-4568-8008-65f7de3f2130
Page Mode                       : UseOutlines
Page Count                      : 211
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q3KRW2058

Navigation menu