Hi Delta® - Type H Job: Engineer: Space Heating/Hot Water Boilers Models 992B-2342B Contractor: Prepared By: Date: Model: Indoor/Outdoor: MBTUH Input: 100% Factory Fire Tested Efficiency: 84% Maximum Outlet Temperature: 230°F Minimum Non-Condensing Inlet Temperature: 105°F Thermal Shock Proof Heat Exchanger Limited Twenty-Year Thermal Shock Warranty Limited Ten-Year Closed-System Heat Exchanger Warranty Diagnostic Center with Fault History PolyTuf Powder Coated Cabinet No Combustible Floor Shield Required Fan-Assisted Patented Burner Security Blanket Heat Exchanger H Stamp Headers Glass-Lined Cast Iron – Standard Bronze – Option A-1 ASME Inspected and Stamped 160 PSIG Working Pressure National Board Approved Fin Tubing Copper – Standard Cupro Nickel – Option A-3 ASME Steel Tube Sheet Silicone High Temp. O-Rings ASME Pressure Relief Valve 60 PSIG – Standard PSIG – Optional Temperature and Pressure Gauge Water Connections Left – Standard Right – Option A-6 Controls 120V, 60Hz, 1∅ Power Supply 120/24V 60Hz Transformer 100% Shut-Off/Lockout Hot Surface Ignition Remote Flame Sensor High Limit Control, Manual Reset On/Off Power Switch Manual Shut-Off, Front-Mounted Flow Switch Blocked Vent Pressure Switch Combustion Air Proving Switches Economaster Pump Time Delay Enable/Disable Catalog No.: 2000.312D Gas Train Manual Gas Shut-Off Valve(s) Gas Pressure Regulator Safety Shut-Off Valve Firing Control Valve Low Gas Pressure Switch, Manual Firing Mode 3-Stage (H8): Model 992B 4-Stage (H9): Models 1262B-2342B Fuel Natural Gas Propane Gas 4” WC Gas Supply Pressure G-20 Design Certified ANSI Z21.13/ CSA 4.9 Construction Indoor/Outdoor Construction Enclosed Front Controls Venting Vent Location Top – Standard Rear – Option D-14 Vent Termination Cap Outdoor D-11 Indoor, Horizontal D-15 Indoor, Vertical (by others) Combustion Air In-Line Filter Kit (TruSeal only) D-17 Air Intake Elbow D-16 Extractor – Optional By others Not required Effective: 11-15-07 Replaces: 1-1-07 Burner Ultra-Low NOx: Less than 30 PPM Temperature Controls BTempTracker Digital Controller, 4-Stage Y-241 Electronic Sequencer, 4-Stage Y-281 Electronic Sequencer, 8-Stage Options C-6 Ignition Module, Manual Reset D-21 TruSeal® Direct Vent F-10 Low Water Cut-Off, Remote Probe I-1 High Limit Control, Auto Reset PPump: HP, 120V, 1∅, 60Hz GPG Water Hardness: Cast Iron Bronze Mounted Loose Front Rear P-26 Cold Water Start (See 2000.49) S-2 High Gas Pressure Switch, Manual X-1 SureRack™ Kit X-2 SureRack Add-on Regulatory Agency Requirements Hi Delta – Type H Models 992B-2342B Model NOTE: Pump location varies based on model and application RATES OF FLOW AND PRESSURE DROPS 20°F ∆T Model GPM ∆P (ft) 992B 84 5.6 1262B 107 10.0 1532B 130 16.0 1802B N/A N/A 2002B N/A N/A 2072B N/A N/A 2342B N/A N/A Min. Flow 30°F ∆T GPM ∆P (ft) GPM ∆P (ft) 56 2.5 42 1.5 4.5 53 2.6 71 7.1 65 4.1 86 76 6.0 102 10.8 85 8.1 113 14.0 88 8.7 117 15.0 99 12.0 132 21.0 Max. Flow ∆T GPM ∆P (ft) ∆T 40 132 14.0 13 40 132 15.5 16 40 132 16.5 20 40 132 18.0 23 40 132 19.5 26 40 132 19.5 27 40 132 21.0 30 Basis is 30 GPM or 40°F ∆T for minimum flow, 132 GPM for maximum flow. SPECIFICATIONS Model 992B 1262B 1532B 1802B 2002B 2072B 2342B MBTUH Firing A H K Input Output Stages Width NPT 990 832 3 57-1/8 2-1/2 10 1260 1058 4 68-1/2 2-1/2 12 1530 1285 4 79-7/8 2-1/2 12 1800 1512 4 91-1/8 2-1/2 14 1999 1679 4 102-1/2 2-1/2 14 2070 1739 4 102-1/2 2-1/2 14 2340 1966 4 113-7/8 2-1/2 16 T W 10 10 10 10 10 10 10 16-13/16 20-9/16 24-3/8 28-1/8 31-15/16 31-15/16 35-11/16 Dimensions are in inches. NOTES: Approx. Amp. Shipping Draw* Wt. (Lbs.) <12 900 <12 1010 <12 1225 <12 1350 <12 1450 <12 1450 <12 1520 * Without pump 1. Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer. 2. Required natural gas pressure is 7 – 10.5” WC. Required propane gas pressure is 11 - 13” WC. Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (800) 872-9725 www.raypak.com Catalog No.: 2000.312D Effective: 11-15-07 Replaces: 1-1-07
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:370cea68-be9b-40de-bcf3-4b949f5b5289 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2007:11:13 15:12:31-08:00 Create Date : 2007:11:13 15:12:31-08:00 Document ID : uuid:e1a1b077-ac63-4209-8511-4c543fa7596f Format : application/pdf Title : Microsoft Word - 2000.312D.doc Creator : tmanapol Author : tmanapolEXIF Metadata provided by EXIF.tools