HOT WATER STORAGE TANK
ASME CODE
175 GALLONS
APPLICATION
The tank can be installed whenever the demand utilizes stored water from 175 gallons or more. Installed individually or
as several tanks in parallel, this tank can provide 80% draw without an appreciable temperature decrease in single
temperature application.
FEATURES
• 175 - Gallon storage
• ASME constructed
• 150 PSI maximum working pressure
• Two magnesium anodes
• Meets ASHRAE 90.1
• Los Angeles city approval
application no. M-880057
• Insulated and jacketed
• R-16 value insulation
• Foam insulation
• Handhole
• Fits through 36” doorway
• Labels for each opening
• Large 1" drain port
• Approx. Shipping Weight: 596 lbs.
CONSTRUCTION CODE
• Storage Tank - The tank is lined with a double
coating of a high-temperature glass formula. It is
built for long life under any water conditions. Two
magnesium anode rods are factory installed.
• R-Foam Insulation - Rigid polyurethane foam insulation for improved economy and fuel savings. The
insulation is R-16 value and complies to ASHRAE
90.1.

•
•

•
•

Steel Jacket - Complete unit is enclosed in baked
enamel steel jacket. With minimum care, the jacket
will remain attractive and colorful for years.
Tank Openings - Circulating tank connections and
hot water outlets are 2-1/2” NPT. Other openings
are for T and P valve, tankstat, thermometer and
drain port. (Drain valve not provided.)
Handhole - Equipped with 3" x 4-1/8" handhole for
easy cleanout and inspection.
Labels - Openings are individually labeled
for easy identification.

SAMPLE SPECIFICATION
The hot water storage tank shall be a Raypak 175-gallon factory insulated and jacketed tank.
The tank shall have a double coating of a high temperature glass lining and be equipped with two (2) magnesium anode
rods. The tank shall be ASME constructed and designed for 150 PSI working pressure and equipped with a handhole
for cleaning and inspection.
The tank shall be insulated with rigid polyurethane foam that completely surrounds the tank and shall be enclosed in
a baked enamel steel jacket. The tank insulation must be R-16 value and must meet or exceed ASHRAE standard 90.1.
The tank shall be covered by a five (5) year limited warranty against corrosion.

Catalog No.: 4000.21K

Effective: 03-15-08

Replaces: 12-28-07

ASME CODE TANK (175 GALLONS)

DRAWING
8054 REV 8

SPECIFICATIONS

(FROM BOILER)
(TO BOILER)

Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725
Litho in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2008:03:20 13:13:06-08:00
Modify Date                     : 2008:03:20 13:13:06-08:00
Page Count                      : 2
Creation Date                   : 2008:03:20 21:13:06Z
Mod Date                        : 2008:03:20 21:13:06Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : tdoyle
Metadata Date                   : 2008:03:20 21:13:06Z
Creator                         : tdoyle
Title                           : 4000.21k.pmd
EXIF Metadata provided by EXIF.tools

Navigation menu