Raypak Hot Water Storage Tank Asme Code Users Manual 4000.21k.pmd
ASME CODE to the manual 0752a786-4ef8-40af-92b8-2a2b69ef2756
2015-02-02
: Raypak Raypak-Hot-Water-Storage-Tank-Asme-Code-Users-Manual-443540 raypak-hot-water-storage-tank-asme-code-users-manual-443540 raypak pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
HOT WATER STORAGE TANK ASME CODE 175 GALLONS APPLICATION The tank can be installed whenever the demand utilizes stored water from 175 gallons or more. Installed individually or as several tanks in parallel, this tank can provide 80% draw without an appreciable temperature decrease in single temperature application. FEATURES • 175 - Gallon storage • ASME constructed • 150 PSI maximum working pressure • Two magnesium anodes • Meets ASHRAE 90.1 • Los Angeles city approval application no. M-880057 • Insulated and jacketed • R-16 value insulation • Foam insulation • Handhole • Fits through 36” doorway • Labels for each opening • Large 1" drain port • Approx. Shipping Weight: 596 lbs. CONSTRUCTION CODE • Storage Tank - The tank is lined with a double coating of a high-temperature glass formula. It is built for long life under any water conditions. Two magnesium anode rods are factory installed. • R-Foam Insulation - Rigid polyurethane foam insulation for improved economy and fuel savings. The insulation is R-16 value and complies to ASHRAE 90.1. • • • • Steel Jacket - Complete unit is enclosed in baked enamel steel jacket. With minimum care, the jacket will remain attractive and colorful for years. Tank Openings - Circulating tank connections and hot water outlets are 2-1/2” NPT. Other openings are for T and P valve, tankstat, thermometer and drain port. (Drain valve not provided.) Handhole - Equipped with 3" x 4-1/8" handhole for easy cleanout and inspection. Labels - Openings are individually labeled for easy identification. SAMPLE SPECIFICATION The hot water storage tank shall be a Raypak 175-gallon factory insulated and jacketed tank. The tank shall have a double coating of a high temperature glass lining and be equipped with two (2) magnesium anode rods. The tank shall be ASME constructed and designed for 150 PSI working pressure and equipped with a handhole for cleaning and inspection. The tank shall be insulated with rigid polyurethane foam that completely surrounds the tank and shall be enclosed in a baked enamel steel jacket. The tank insulation must be R-16 value and must meet or exceed ASHRAE standard 90.1. The tank shall be covered by a five (5) year limited warranty against corrosion. Catalog No.: 4000.21K Effective: 03-15-08 Replaces: 12-28-07 ASME CODE TANK (175 GALLONS) DRAWING 8054 REV 8 SPECIFICATIONS (FROM BOILER) (TO BOILER) Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Litho in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2008:03:20 13:13:06-08:00 Modify Date : 2008:03:20 13:13:06-08:00 Page Count : 2 Creation Date : 2008:03:20 21:13:06Z Mod Date : 2008:03:20 21:13:06Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : tdoyle Metadata Date : 2008:03:20 21:13:06Z Creator : tdoyle Title : 4000.21k.pmdEXIF Metadata provided by EXIF.tools