Raytek Mid Users Manual
MID to the manual 8bd5adce-bbe0-4601-abc3-2aac280fbdc0
2015-02-06
: Raytek Raytek-Mid-Users-Manual-502382 raytek-mid-users-manual-502382 raytek pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
Raytek MID Noncontact Infrared Temperature Sensor Product Description The MID™ is a two-piece infrared temperature measurement system with Highlights: miniature sensing head and separate electronics. The sensor is small enough to be installed just about anywhere, yet it performs as well as much larger systems. And the MID electronics include a host of signal processing features which you won’t normally find in systems in this price range, including Emissivity, Peak Hold, Valley Hold, and Averaging, • Small sensing head fits where other sensors can’t • Ambient operating range to 85°C (185°F) without cooling • 5-digit backlit LCD interface all of which are adjustable on the 5-digit LCD interface. • Adjustable emissivity, peak hold, valley hold and averaging Designed for applications where the target temperature is in the -40 to • 1% Accuracy from -40 to 600°C (-40 to 1112°F) 600°C (-40 to 1112°F) range, the sensor is housed in a rugged stainless • Choice of 2:1 or 10:1 optics steel enclosure to ensure long term performance, even in harsh industrial environments with ambient temperatures up to 85°C (185°F) without • Powered by 12-24 VDC at ≤100 mA cooling. • Accessories for cooling and air purging Although the MID is small in size, it still has the features you need, • Remote electronics box with 1% accuracy and a choice of 2:1 or 10:1 optics, with user selectable output signals. And the MID’s response time is as fast or faster than many high-end systems. The MID’s miniature size and low cost make it ideal for installation at multiple points along your process. Accurate. Easy to install. Affordable. With the MID, precision infrared temperature measurement is now an economical alternative. • User selectable output signals • Optional RS232 or RS485 communication Raytek MID Nominal Optical Specifications Measurement Specifications Spectral Response: Optical Resolution: Temperature Range: System Accuracy: System Repeatability: Temperature Coefficient: Temperature Resolution: System Response Time: Emissivity: Transmission: Signal Processing: 8 to 14 microns 2:1 or 10:1 -40 to 600°C (-40 to 1112°F); -25 to 600°C for J-thermocouple output ±1% of reading or ±1°C, whichever is greater @23°C±5°C (73°F±9°F). Thermocouple output accuracy ±1% of reading or ±2.5°C, whichever is greater @23°C±5°C ±0.5% of reading or ±0.5°C (1°F), whichever is greater 0.15K per K or 0.15% per K, whichever is greater 0.3°C or 0.5°F 150ms (95%) 0.100 to 1.100 digitally adjustable increments of .001 0.100 to 1.100 digitally adjustable increments of .001 Peak Hold, Valley Hold, Variable Averaging Filter, adjustable up to 998 seconds D:S is the optical resolution expressed as a ratio of the distance to the resolution spot divided by the diameter of the spot. Optical resolution for the MID is 2:1 and 10:1. Nominal spot size based on 90% energy. General Dimensions Sensing Head Electrical Specifications Outputs: Cable Length Output Impedance (T/C output) Minimum Load Impedance (mV output) Maximum Loop Impedance (mA output) Current Draw: Power Supply Scalable 4-20mA, 0-20mA, 0-5V, J or K thermocouple 10mV/°C Head Ambient signal 1 m (3.2 ft) standard, 3m (9.8 ft.) optional 20 ohm 100K ohms 500 ohms with 24 VDC power supply 100 mA 11-26 VDC Electronics Housing 25 (1.0) 60 (2. 4) General Specifications Environmental Rating Ambient Temperature Range: Sensing head With air cooling Electronics housing Storage Temperature Relative Humidity Construction: Sensing head Electronics housing Weight: Sensing head (w/1 m cable) Electronics housing NEMA-4 (IP 65) 0 to 85°C (32 to 185°F) -18 to 200°C (0 to 392°F) 0 to 65°C (32 to 150°F) -18 to 85°C (0 to 185°F) 10 to 95%, non-condensing Stainless steel Zinc, die-cast 80 ) 2 (3. mm (in) Accessories / Options* Each standard MID package includes a sensing head, one mounting nut, 1 m (3.2 ft) of cable, die-cast housing with premounted electronics, and an operator’s manual • Adjustable or fixed mounting bracket • Air purge jacket • Air cooling/purging system • Longer cable: 3m (9.8 ft.)* 50 g (1.75 oz) 270 g (9.5 oz) • Rs232 or RS485 communication* *Must be specified at time of order For Sales and Ordering Contact: 5710 Kenosha Street Richmond, Illinois 60071 USA Phone: +1 (815) 678-2211 FAX: +1 (815) 678-3961 Internet: www.watlow.com e-mail: info@watlow.com Your Authorized W atlow Distributor Is: For Service and W arranty Contact: Worldwide Headquarters Raytek Corporation Santa Cruz, CA USA Tel: 1 831 458 1110 800 227 8074 (U.S. and Canada only) Fax: 1 831 458 1239 www.raytek.com Raytek, the Raytek logo, and Thermalert are registered trademarks of Raytek Corporation. ©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A Specifications subject to change without notice. 3-1022 RIC-MID-0401
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 2001:04:09 13:02:19 Producer : Acrobat Distiller 4.05 for Macintosh Modify Date : 2001:04:26 10:27:12-05:00 Title : Raytek MID Author : Watlow Communication's Team Page Count : 2 Page Mode : UseOutlines Page Layout : OneColumnEXIF Metadata provided by EXIF.tools