Redline Communications RDL3000RM Advanced Broadband Wireless Infrastructure Solution User Manual 70 00184 01 00

Redline Communications Inc. Advanced Broadband Wireless Infrastructure Solution 70 00184 01 00

Users manual

70-00184-01-00 Proprietary Redline Communications © 2012 Page 1 of 14 March 1, 2012
RDL-3000 Family
Broadband Wireless Radio Platforms
RDL-3000-RM
Radio Module
Product Manual
1 Product Overview ................................................................... 4
2 Conditions of Use ................................................................... 5
3 Module Installation and Service ............................................ 6
4 Final Product Requirements .................................................. 7
5 Regulatory Notices ............................................................... 11
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 2 of 14 March 1, 2012
Copyright Information
All rights reserved March 1, 2012. The information in this document is proprietary to
Redline Communications Inc. This document may not in whole or in part be copied,
reproduced, or reduced to any medium without prior consent, in writing, from Redline
Communications Incorporated.
Contact Information:
Redline Communications Inc.
302 Town Centre Blvd.
Markham, ON
Canada L3R 0E8
Web site:
http://www.rdlcom.com
Email: Inquiries: info@rdlcom.com
Support: support@rdlcom.com
Training: training@rdlcom.com
Document Control:
70-00184-01-00-RDL-3000-RM_Product_Manual-20120301a.doc
Disclaimer
The statements, configurations, technical data, and recommendations in this document
are believed to be accurate and reliable, but are presented without express or implied
warranty. Additionally, Redline makes no representations or warranties, either expressed
or implied, regarding the contents of this product. Redline Communications shall not be
liable for any misuse regarding this product. The information in this document is subject
to change without notice. No part of this document shall be deemed to be part of any
warranty or contract unless specifically referenced to be part of such warranty or
contract within this document.
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 3 of 14 March 1, 2012
TABLE OF CONTENTS
1 Product Overview ................................................................... 4
2 Conditions of Use ................................................................... 5
2.1 General Conditions ............................................................................................ 5
2.2 Country of Use ................................................................................................... 5
2.3 Product Labeling ................................................................................................ 5
3 Module Installation and Service ............................................ 6
3.1 Installation Into a Final Product ........................................................................ 6
3.2 Module Servicing ............................................................................................... 6
3.3 Professional Installation .................................................................................... 6
3.4 Safety Precautions ............................................................................................. 6
3.5 Radio Frequency Safety .................................................................................... 6
4 Final Product Requirements .................................................. 7
4.1 Frequency Bands ............................................................................................... 7
4.2 Antenna Use and Transmit Power .................................................................... 7
4.3 Certified Antennas ............................................................................................. 7
4.4 Power and EIRP Results (MIMO Operation) ..................................................... 7
Operation in the 5725-5850 MHz Band: FCC & IC ......................................... 7
Operation in the 4940-4990 MHz Band: FCC ................................................. 8
Operation in the 4940-4990 MHz Band: IC ..................................................... 9
5 Regulatory Notices ............................................................... 11
FCC Notices: Deployment in USA: ............................................................... 11
Industry Canada Notices: Deployment in Canada: ....................................... 12
LIST OF TABLES
Table 1: Approved Antennas ........................................................................................... 7
Table 2: Power & EIRP Results: 5725-5850 MHz FCC & IC - 5 MHz Channel ................ 7
Table 3: Power & EIRP Results: 5725-5850 MHz FCC & IC - 10 MHz Channel .............. 8
Table 4: Power & EIRP Results: 5725-5850 MHz FCC & IC - 20 MHz Channel .............. 8
Table 5: Power & EIRP Results: 4940-4990 MHz FCC - 5 MHz Channel ........................ 8
Table 6: Power & EIRP Results: 4940-4990 MHz FCC - 10 MHz Channel ...................... 9
Table 7: Power & EIRP Results: 4940-4990 MHz FCC - 20 MHz Channel ...................... 9
Table 8: Power & EIRP Results: 4940-4990 MHz IC - 5 MHz Channel ............................ 9
Table 9: Power & EIRP Results: 4940-4990 MHz IC - 10 MHz Channel ........................ 10
Table 10: Power & EIRP Results: 4940-4990 MHz IC - 20 MHz Channel ...................... 10
Table 11: Recommended Safe Distances ...................................................................... 11
Table 12: Recommended Safe Distances ...................................................................... 12
Table 13: Avis - IC RF Distances de séparation sécuritaire recommandées .................. 13
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 4 of 14 March 1, 2012
1 Product Overview
The RDL-3000 Radio Module (RDL-3000-RM) is comprised of a proprietary Media
Access Control (MAC) protocol engine and Time Division Duplexing (TDD)/ Orthogonal
Frequency Division Duplexing (OFDM) digital radio.
The RDL-3000-RM is not designed for stand-alone operation. The module is sold as one
component of a packaged system which includes a suitable housing for the module
connectors for required external components including a power supply and antenna
system. This is afterwards referred to as the 'final product'. The final product may be
designed and manufactured by Redline or a licensed third party.
The module is available in the 4900 to 5800 MHz frequency band. Frequency settings
within this band are software keyed to be compliant with specific regulatory agency
requirements in the region of deployment.
Important: Read this entire document prior to installing or operating the RDL-3000-RM.
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 5 of 14 March 1, 2012
2 Conditions of Use
2.1 General Conditions
The RDL-3000-RM is not provided for sale to the general public.
The RDL-3000-RM contains a proprietary radio interface and can not be directly
connected to any standard telecommunications or computer devices.
This manual is provided as supplement to technical and operational documentation and
training provided by Redline and its agents. Any operation or use of the RDL-3000-M in
any manner not expressly specified within this manual or approved in writing by Redline
(or its agents) is expressly forbidden and voids the users right to operate the module.
This includes, but is not limited to, any modification of the module hardware or software,
installation of the module in a non approved enclosure, and use with non approved
antennas.
2.2 Country of Use
The RDL-3000-RM is certified with limiter modular approval for use as an 'intentional
radiator' in Canada as IC: 4310A-RDL3000RM and in the United States as device FCC
ID: QC8-RDL3000RM, and .
Refer to the regulatory notices in this document before installing or operating the RDL-
3000-RM.
2.3 Product Labeling
Information labels are applied to the final product. The final product features a label on
the outside surface listing the registration number for the enclosed RDL-3000-RM
module:
Contains: IC 4310A-RDL3000RM
FCC ID:QC8-RDL3000RM
Do not to remove any labels from the module or the final product.
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 6 of 14 March 1, 2012
3 Module Installation and Service
3.1 Installation Into a Final Product
The RDL-3000-RM must only be installed by trained professional technicians authorized
by Redline or its agents. The module must be installed only into an approved enclosure
(see Conditions of Use) and only at an approved manufacturing facility or service depot.
3.2 Module Servicing
The RDL-3000-RM is not intended to be field serviceable, and contains no field
serviceable or field replaceable parts. The module must be serviced only at an approved
manufacturing facility or service depot.
Warning: The RDL-3000-RM is susceptible to damage from electrostatic charge.
Electrostatic Discharge (ESD) must be avoided to prevent damaging or destroying the
module. The module must always be store in an anti-static container/bag prior to
installation and following removal from the product for servicing. Observe ESD
precautions when handling the module.
3.3 Professional Installation
Devices containing the Redline RDL-3000-RM require professional installation. It is the
responsibility of the installer understand the product operation by attending training
as required, reading and understanding the product documentation, and ensuring
that all building, safety and regulatory codes are met and the installation is complete
and secure.
3.4 Safety Precautions
Installation and service must be done by personnel having technical training and
experience necessary to be aware of hazards during installation and/or service of RF
equipment. The installation and/or service must be done using procedures designed to
minimize any danger to technical personnel or any other person.
3.5 Radio Frequency Safety
The installer of this radio equipment must ensure that the antenna is located or pointed
such that it does not emit RF fields in excess of the general population limits as defined
by FCC CFR 47, Part 2.1091, Radio frequency radiation exposure evaluation for fixed
devices & Health Canada limits for the general population; consult Safety Code 6,
obtainable from Health Canadas website:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php .
Refer to the regulator statements included in this document.
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 7 of 14 March 1, 2012
4 Final Product Requirements
The following requirements apply to all final products incorporating the RDL-3000-RM.
4.1 Frequency Bands
Operation of the final product requires a software 'key' that is available exclusively from
Redline. This key restricts device operation to the FCC/IC 4940-4990 MHz or 5725-5850
MHz band. The professional installer and operator can not modify or otherwise
circumvent these operational restrictions.
4.2 Antenna Use and Transmit Power
The RDL-3000-RM module supports operation with 2x2 MIMO antenna systems with two
transmit chains and two receive chains. The RDL-3000-RM module must be used only
with certified antennas and using the channel size and output power level specified by
the FCC/IC regulations.
4.3 Certified Antennas
This device has been designed to operate with the antennas listed in the following table.
Any additional antennas will be used only after authorization is obtained through Class II
permissive change.
Table 1: Approved Antennas
Manufacturer
Part #
Gain
Frequency Range
Redline
30-00328-00
19 dBi
4900-5875 MHz
4.4 Power and EIRP Results (MIMO Operation)
Operation in the 5725-5850 MHz Band: FCC & IC
For operation in the 5725-5850 MHz band, the RDL-3000-RM may be set to operate
using a 5, 10, or 20 MHz channel.
Table 2: Power & EIRP Results: 5725-5850 MHz FCC & IC - 5 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
5727.5
13.79
13.53
16.67
17.00
0.33
19.00
35.67
36.00
0.33
5790.0
13.89
13.41
16.67
17.00
0.33
19.00
35.67
36.00
0.33
5847.5
13.97
13.45
16.73
17.00
0.27
19.00
35.73
36.00
0.27
QPSK
5727.5
13.81
13.50
16.67
17.00
0.33
19.00
35.67
36.00
0.33
5790.0
13.93
13.35
16.66
17.00
0.34
19.00
35.66
36.00
0.34
5847.5
13.96
13.48
16.74
17.00
0.26
19.00
35.74
36.00
0.26
16-QAM
5727.5
13.84
13.49
16.68
17.00
0.32
19.00
35.68
36.00
0.32
5790.0
13.84
13.36
16.62
17.00
0.38
19.00
35.62
36.00
0.38
5847.5
13.95
13.48
16.73
17.00
0.27
19.00
35.73
36.00
0.27
64-QAM
5727.5
13.94
13.65
16.81
17.00
0.19
19.00
35.81
36.00
0.19
5790.0
13.91
13.40
16.67
17.00
0.33
19.00
35.67
36.00
0.33
5847.5
14.21
13.47
16.87
17.00
0.13
19.00
35.87
36.00
0.13
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 8 of 14 March 1, 2012
Table 3: Power & EIRP Results: 5725-5850 MHz FCC & IC - 10 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
5730.0
13.53
13.38
16.47
17.00
0.53
19.00
35.47
36.00
0.53
5790.0
13.81
13.61
16.72
17.00
0.28
19.00
35.72
36.00
0.28
5845.0
13.48
13.65
16.58
17.00
0.42
19.00
35.58
36.00
0.42
QPSK
5730.0
13.73
13.51
16.63
17.00
0.37
19.00
35.63
36.00
0.37
5790.0
13.37
13.55
16.47
17.00
0.53
19.00
35.47
36.00
0.53
5845.0
13.33
13.57
16.46
17.00
0.54
19.00
35.46
36.00
0.54
16-QAM
5730.0
13.96
13.44
16.72
17.00
0.28
19.00
35.72
36.00
0.28
5790.0
13.30
13.59
16.46
17.00
0.54
19.00
35.46
36.00
0.54
5845.0
13.39
13.56
16.49
17.00
0.51
19.00
35.49
36.00
0.51
64-QAM
5730.0
14.26
13.21
16.78
17.00
0.22
19.00
35.78
36.00
0.22
5790.0
13.12
13.68
16.42
17.00
0.58
19.00
35.42
36.00
0.58
5845.0
13.33
13.59
16.47
17.00
0.53
19.00
35.47
36.00
0.53
Table 4: Power & EIRP Results: 5725-5850 MHz FCC & IC - 20 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
5735.0
13.32
13.63
16.49
17.00
0.51
19.00
35.49
36.00
0.51
5790.0
13.99
13.47
16.75
17.00
0.25
19.00
35.75
36.00
0.25
5840.0
13.35
13.95
16.67
17.00
0.33
19.00
35.67
36.00
0.33
QPSK
5735.0
13.33
13.61
16.48
17.00
0.52
19.00
35.48
36.00
0.52
5790.0
14.01
13.53
16.79
17.00
0.21
19.00
35.79
36.00
0.21
5840.0
13.32
13.79
16.57
17.00
0.43
19.00
35.57
36.00
0.43
16-QAM
5735.0
13.43
13.62
16.54
17.00
0.46
19.00
35.54
36.00
0.46
5790.0
14.01
13.61
16.82
17.00
0.18
19.00
35.82
36.00
0.18
5840.0
13.32
13.74
16.55
17.00
0.45
19.00
35.55
36.00
0.45
64-QAM
5735.0
13.62
13.61
16.63
17.00
0.37
19.00
35.63
36.00
0.37
5790.0
13.99
13.79
16.90
17.00
0.10
19.00
35.90
36.00
0.10
5840.0
13.29
13.68
16.50
17.00
0.50
19.00
35.50
36.00
0.50
Operation in the 4940-4990 MHz Band: FCC
For operation in the 4940-4990 MHz band, the RDL-3000-RM may be set to operate
using a 5, 10, or 20 MHz channel.
Table 5: Power & EIRP Results: 4940-4990 MHz FCC - 5 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
4942.5
19.07
18.34
21.73
27.00
5.27
19.00
40.73
53.00
12.27
4965.0
18.91
19.00
21.97
27.00
5.03
19.00
40.97
53.00
12.03
4987.5
19.41
19.65
22.54
27.00
4.46
19.00
41.54
53.00
11.46
QPSK
4942.5
18.60
18.29
21.46
27.00
5.54
19.00
40.46
53.00
12.54
4965.0
18.65
20.12
22.46
27.00
4.54
19.00
41.46
53.00
11.54
4987.5
18.33
19.31
21.86
27.00
5.14
19.00
40.86
53.00
12.14
16-QAM
4942.5
18.52
18.25
21.40
27.00
5.60
19.00
40.40
53.00
12.60
4965.0
18.57
18.86
21.73
27.00
5.27
19.00
40.73
53.00
12.27
4987.5
19.14
18.40
21.80
27.00
5.20
19.00
40.80
53.00
12.20
64-QAM
4942.5
18.76
19.44
22.12
27.00
4.88
19.00
41.12
53.00
11.88
4965.0
18.79
18.77
21.79
27.00
5.21
19.00
40.79
53.00
12.21
4987.5
19.53
19.25
22.40
27.00
4.60
19.00
41.40
53.00
11.60
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 9 of 14 March 1, 2012
Table 6: Power & EIRP Results: 4940-4990 MHz FCC - 10 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
4945.0
18.55
19.26
21.93
30.00
8.07
19.00
40.93
56.00
15.07
4965.0
18.45
18.67
21.57
30.00
8.43
19.00
40.57
56.00
15.43
4985.0
18.91
19.03
21.98
30.00
8.02
19.00
40.98
56.00
15.02
QPSK
4945.0
18.16
19.22
21.73
30.00
8.27
19.00
40.73
56.00
15.27
4965.0
18.07
19.78
22.02
30.00
7.98
19.00
41.02
56.00
14.98
4985.0
18.82
18.92
21.88
30.00
8.12
19.00
40.88
56.00
15.12
16-QAM
4945.0
18.10
19.22
21.71
30.00
8.29
19.00
40.71
56.00
15.29
4965.0
18.12
18.63
21.39
30.00
8.61
19.00
40.39
56.00
15.61
4985.0
18.60
18.99
21.81
30.00
8.19
19.00
40.81
56.00
15.19
64-QAM
4945.0
18.54
19.22
21.90
30.00
8.10
19.00
40.90
56.00
15.10
4965.0
18.56
18.56
21.57
30.00
8.43
19.00
40.57
56.00
15.43
4985.0
19.17
18.89
22.04
30.00
7.96
19.00
41.04
56.00
14.96
Table 7: Power & EIRP Results: 4940-4990 MHz FCC - 20 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
4950.0
20.08
20.95
23.55
33.00
9.45
19.00
42.55
59.00
16.45
4965.0
19.73
20.04
22.90
33.00
10.10
19.00
41.90
59.00
17.10
4980.0
20.11
20.23
23.18
33.00
9.82
19.00
42.18
59.00
16.82
QPSK
4950.0
20.45
20.71
23.59
33.00
9.41
19.00
42.59
59.00
16.41
4965.0
19.88
19.95
22.93
33.00
10.07
19.00
41.93
59.00
17.07
4980.0
20.23
20.13
23.19
33.00
9.81
19.00
42.19
59.00
16.81
16-QAM
4950.0
20.35
20.61
23.49
33.00
9.51
19.00
42.49
59.00
16.51
4965.0
19.74
19.86
22.81
33.00
10.19
19.00
41.81
59.00
17.19
4980.0
21.19
20.10
23.69
33.00
9.31
19.00
42.69
59.00
16.31
64-QAM
4950.0
19.98
20.84
23.44
33.00
9.56
19.00
42.44
59.00
16.56
4965.0
19.59
19.97
22.79
33.00
10.21
19.00
41.79
59.00
17.21
4980.0
19.97
20.17
23.08
33.00
9.92
19.00
42.08
59.00
16.92
Operation in the 4940-4990 MHz Band: IC
For operation in the 4940-4990 MHz band, the RDL-3000-RM may be set to operate
using a 5, 10, or 20 MHz channel.
Table 8: Power & EIRP Results: 4940-4990 MHz IC - 5 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
4942.5
21.49
21.15
24.33
27.00
2.67
19.00
43.33
53.00
9.67
4965.0
21.53
21.83
24.69
27.00
2.31
19.00
43.69
53.00
9.31
4987.5
22.10
21.08
24.63
27.00
2.37
19.00
43.63
53.00
9.37
QPSK
4942.5
21.39
21.19
24.30
27.00
2.70
19.00
43.30
53.00
9.70
4965.0
21.64
20.76
24.23
27.00
2.77
19.00
43.23
53.00
9.77
4987.5
20.98
21.02
24.01
27.00
2.99
19.00
43.01
53.00
9.99
16-QAM
4942.5
21.49
21.05
24.29
27.00
2.71
19.00
43.29
53.00
9.71
4965.0
21.67
20.85
24.29
27.00
2.71
19.00
43.29
53.00
9.71
4987.5
20.96
20.86
23.92
27.00
3.08
19.00
42.92
53.00
10.08
64-QAM
4942.5
21.47
21.18
24.34
27.00
2.66
19.00
43.34
53.00
9.66
4965.0
21.63
20.83
24.26
27.00
2.74
19.00
43.26
53.00
9.74
4987.5
20.95
21.01
23.99
27.00
3.01
19.00
42.99
53.00
10.01
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 10 of 14 March 1, 2012
Table 9: Power & EIRP Results: 4940-4990 MHz IC - 10 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
4945.0
24.96
25.43
28.21
30.00
1.79
19.00
47.21
56.00
8.79
4965.0
24.72
24.92
27.83
30.00
2.17
19.00
46.83
56.00
9.17
4985.0
25.34
25.05
28.21
30.00
1.79
19.00
47.21
56.00
8.79
QPSK
4945.0
24.84
25.32
28.10
30.00
1.90
19.00
47.10
56.00
8.90
4965.0
24.72
24.82
27.78
30.00
2.22
19.00
46.78
56.00
9.22
4985.0
25.33
25.01
28.18
30.00
1.82
19.00
47.18
56.00
8.82
16-QAM
4945.0
24.71
25.34
28.05
30.00
1.95
19.00
47.05
56.00
8.95
4965.0
24.72
24.64
27.69
30.00
2.31
19.00
46.69
56.00
9.31
4985.0
25.30
25.16
28.24
30.00
1.76
19.00
47.24
56.00
8.76
64-QAM
4945.0
24.68
25.41
28.07
30.00
1.93
19.00
47.07
56.00
8.93
4965.0
24.80
24.85
27.84
30.00
2.16
19.00
46.84
56.00
9.16
4985.0
25.34
25.11
28.24
30.00
1.76
19.00
47.24
56.00
8.76
Table 10: Power & EIRP Results: 4940-4990 MHz IC - 20 MHz Channel
Modulation
Frequency
(MHz)
Conducted
power,
port 2
(dBm)
Combined
power
(dBm)
Conducted
power
limit (dBm)
Margin
Antenna
gain
(dBi)
EIRP
(dBm)
EIRP
limit
(dBm)
Margin
(dB)
BPSK
4950.0
30.01
29.53
32.79
33.00
0.21
19.00
51.79
59.00
7.21
4965.0
29.69
29.67
32.69
33.00
0.31
19.00
51.69
59.00
7.31
4980.0
29.76
30.11
32.95
33.00
0.05
19.00
51.95
59.00
7.05
QPSK
4950.0
30.19
29.27
32.76
33.00
0.24
19.00
51.76
59.00
7.24
4965.0
29.52
29.97
32.76
33.00
0.24
19.00
51.76
59.00
7.24
4980.0
29.92
30.04
32.99
33.00
0.01
19.00
51.99
59.00
7.01
16-QAM
4950.0
29.86
29.49
32.69
33.00
0.31
19.00
51.69
59.00
7.31
4965.0
29.73
29.80
32.78
33.00
0.22
19.00
51.78
59.00
7.22
4980.0
30.18
28.70
32.51
33.00
0.49
19.00
51.51
59.00
7.49
64-QAM
4950.0
30.22
29.06
32.69
33.00
0.31
19.00
51.69
59.00
7.31
4965.0
30.63
28.47
32.69
33.00
0.31
19.00
51.69
59.00
7.31
4980.0
30.05
28.85
32.50
33.00
0.50
19.00
51.50
59.00
7.50
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 11 of 14 March 1, 2012
5 Regulatory Notices
FCC Notices: Deployment in USA:
The following notices about deployment in the USA are included in training and
documentation provided to professional installers and operators of the final product:
1. The final product must be professionally installed.
2. WARNING -- FCC RF Exposure Warnings
To satisfy FCC RF exposure requirements for RF transmitting devices, the following
distances should be maintained between the antenna of this device and persons
during device operation:
Table 11: Recommended Safe Distances
Frequency (GHz)
Deployment
Separation Distance
4.9 - 5.3
PMP
120 cm (47.25 in) or more
5.8
PMP
20 cm (7.8 in) or more
To ensure compliance, operation at closer than these distances is not
recommended. The antenna used for this transmitter must not be collocated in
conjunction with any other antenna or transmitter.
3. FCC Information to Users @ FCC 15.105:
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Where DFS is required by regional regulations, this function is permanently enabled
at the factory and can not be disabled by the installer or end-user.
4. FCC Information to Users @ FCC 15.19:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that
may cause undesired operation.
5. FCC Information to Users @ FCC 15.21:
Warning: Changes or modifications not expressly approved by Redline
Communications could void the user’s authority to operate the equipment.
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 12 of 14 March 1, 2012
Industry Canada Notices: Deployment in Canada:
The RDL-3000-RM has been designed to operate with an antenna having a maximum
gain of 19 dBi. Antenna having a higher gain is strictly prohibited per regulations of
Industry Canada. The required antenna impedance is 50 ohms.
This device has been designed to ensure that radio frequency emissions are maintained
within the band of operation under all normal operating conditions listed in this manual.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation
is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropic radiated power (EIRP) is not more than
that required for successful communication.
This Class B Digital apparatus meets all the requirements of the Canadian Interference-
Causing Equipment.
The following notices about deployment in Canada are included in training and
documentation provided to professional installers and operators of the final product:
1. The final product must be professionally installed.
2. WARNING -- IC RF Exposure Warnings
To satisfy IC RF exposure requirements for RF transmitting devices, the following
distances should be maintained between the antenna of this device and persons
during device operation:
Table 12: Recommended Safe Distances
Frequency (GHz)
Deployment
Separation Distance
4.9 - 5.3
PMP
120 cm (47.25 in) or more
5.8
PMP
20 cm (7.8 in) or more
To ensure compliance, operation at closer than these distances is not
recommended. The antenna used for this transmitter must not be collocated in
conjunction with any other antenna or transmitter.
Déploiement aux le Canada
Le RDL-3000-RM a été conçu pour fonctionner avec une antenne ayant un gain
maximal de 19 dBi. Antenne ayant un gain plus élevé est strictement interdite par les
règlements d'Industrie Canada. L'impédance d'antenne requise est de 50 ohms.
Ce dispositif a été conçu pour veiller à ce que les émissions de radiofréquences sont
maintenus dans la bande de fonctionnement dans toutes les conditions normales de
fonctionnement figurant dans ce manuel.
Cet appareil est conforme la norme d'Industrie Canada exempts de licence RSS (s). Son
fonctionnement est soumis aux deux conditions suivantes:
1. Cet appareil ne peut pas causer d'interférences, et
2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement de l'appareil.
RDL-3000 FAMILY RM PRODUCT MANUAL
70-00184-01-00 Proprietary Redline Communications © 2012 Page 13 of 14 March 1, 2012
Pour réduire le potentiel d’interférence radio sur d’autres utilisateurs, le type d’antenne
et son gain doivent être choisies tel que la Puissance Isotrope Rayonnée Equivalente
(PIRE) ne dépasse pas le niveau nécessaire pour une communication efficace.
Cet appareil Digitale de Classe B rencontre toutes les normes du Canadian Règlement
Brouilleur Équipement.
Les avis suivants à propos du déploiement au Canada sont inclus dans la formation et la
documentation fournies aux installateurs professionnels et les opérateurs du produit
final:
1. Le modèle RDL-3000 et son antenne doivent être installés par un professionnel.
2. AVERTISSEMENT - IC avertissements d'exposition RF
Pour satisfaire les exigences d’IC en ce qui a trait aux expositions aux RF pour RF
dispositifs de transmission, les distances suivantes doit être maintenue entre
l'antenne de ce dispositif et des personnes pendant le fonctionnement du dispositif:
Table 13: Avis - IC RF Distances de séparation sécuritaire recommandées
Fréquence (GHz)
Déploiement
Distance de Séparation
4.9 - 5.3
PMP
120 cm (47.25 in) ou plus
5.8
PMP
20 cm (8 in) ou plus
Pour assurer la conformité , l’operation à une distance moindre que celles-ci n'est
pas recommandé. L'antenne utilisée pour ce transmetteur ne doit pas être co-
localisé avec une autre antenne ou transmetteur.
70-00184-01-00 Proprietary Redline Communications © 2012 Page 14 of 14 March 1, 2012
302 Town Centre Markham, Ontario Canada L3R 0E8
www.rdlcom.com

Navigation menu