Remote Control Solutions T433CKPD Keypad User Manual 519 DipSwitch Instructions

Remote Control Solutions, LLC Keypad 519 DipSwitch Instructions

Users Manual

DIP-SWITCH KEYPADMANUALOF INSTALLATIONRCS-433CKPDIntroductionRCS-433CKPD Keypad is a codified radio keyboard operating at 433,92 MHz.The best use of the product is on applications where a codified radio signal has to be used to control:gates, garage doors, rolling shutters, sun-blinds, anti-burglar appliances, lightings, etc. The code has a very high security coding system (19683 code combinations). The radio transmission is enabled only afterthe dialing of a security user code. There are up to 6 different channels that can activate up to 6 differentreceivers or relays. Compatible receivers: RCS-433DSR2LC, RCS-433BR2.The internal memory can store up to 24 different security user codes and 1 Master code.The product fully complies with Part. 15 of FCC Rules.INSTALLATIONTechnical SpecificationsNumber of keys: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Number of channels: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 VdcBattery duration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . about 36 monthsBattery type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lithium CR123ACurrent consumption: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mAOperating frequency:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433.92 MHzModulation: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AM/ASKE.r.p.:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 mWSecurity Code combinations number:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19683User security code number:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24+1Transmission duration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . until press / 2 sec.Range in open space:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . from 150 to 700 mOperating temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . from 14 °F to 131 °FDimensions:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.84*60.84*0.6mmWeight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ozIP Protection Grade: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65Battery Removal & ReplacementRemove the cover and extract the old battery from the bottom site of the electronic card with an upward traction.Insert the new battery on the battery location, respecting the right polarity.Installation of Keypad1 -  Locate the best position for the fixing, avoiding metallic surfaces that could decrease the RF emission;2 -  Mark the location of the fixing holes using the bottom of the box as drilling template;3 -  Drill the fixing holes and insert the plugs;4 -  Remove the protection strip from the seal;5 -  Assemble the seal and the bottom;6 -  Fix the bottom with the screws supplied;7 -  Mount the cover on the fixed bottom;8 -  Fix the cover to the bottom with the 2 screws supplied.NOTES: The keypad uses lithiumbattery type CR123A-S-3V. Theremoval and the disposal of the battery must be done before thedisposal of the keypad and according to the currentRegulations.ATTENTION: Danger of explosion ifthe battery is not replaced in thecorrect way!       FCC ID: ____________This device complies with FCC Rules Part 15 Operation is subject to the following two conditions:1) This device may not cause harmful interferences;2) this device must accept interference that may cause undesired operation.PasswordThe keypad has a Master Password factory-set to “11111”.It is suggested that the Master Password be changed to avoid miss-use of keypad.The Master Password and the User code can have up to 5 digits. If the chosen code is shorter than 5 digits,then a “#” must be pressed after the last digit, to complete the number, as indicated below:_ Example 1 : User code 123 : Digit 1, 2, 3, #._ Example 2 : User code 1234 : Digit 1, 2, 3, 4,#.• the master password does not need to be changed to enter programming mode. If the end user would like to keep the password at the factory default they can, although not recommended.• If at any time the user dials a wrong code there will be a distinct LONG beeeeep to let the user know they have pressed something wrong and need to start over.• If the user presses the *key twice it will clear the keys dialed and the user can start over.• When memorizing the dip-switch setting on the receiver this process learns the keypads' specific security code/dip-switch setting and not just the user code. After this process is done all the user codes that are in the keypad will activate the respective relay that the security code/dip-switch setting was learned to.Memorizing Keypad Dip-Switch Setting on Receiver1Press relay (1, 2, 3 or 4) learn button on receiver until LED is lit on receiver.2Release receiver button and while the LED is lit on receiver press the user code on keypad and leave last digit of user code press for 2 sec.3Receiver LED will blink to confirm keypad dip-switch setting memorization.Special FunctionsThe “*” key will cancel the last command.WARNING: “Changes or modifications not expresslyapproved by the manufacturer could void the user'sauthority to operate the equipment”.NOTE: You can modify each individual dip-switch setting at a time if desired;Example 2  –  Change dip-switch 2 from “0” to “#”.STEP 1: Dial the “Master Password”STEP 2: Press “6”CHANGESTEP 3: Dial only “2#”STEP 4: Press “#” then “6”Master Password Replacement1 2 3 4 5 6       Dial the factory Press “8” Dial the new Press “8” Confirm the new Press “8”default master(then two beepsmaster password master password(two beepspassword (11111) to confirm) confirm)New User Memorization Procedure1 2 3 4 5 6       Dial the master Press “9” Dial the desired Press “9” Confirm new Press “9”password (two beepsuser code user code(two beepsconfirm entry in confirmprogramming mode) programming)“Beep Beep” “Beep Beep”“Beep Beep” “Beep Beep”Single User Cancellation Procedure1 2 3 4 5 6       Dial the master Press “7” Dial the user code Press “7” Confirm the user Press “7”password (two beepsto be canceled code to be (two beepsconfirm entry incanceledconfirm programming mode) cancellation)“Beep Beep” “Beep Beep”All User Cancellation Procedure1 2 3 4 5 6       Dial the master Press “7” Dial the master Press “7” Confirm the Press “7”password (two beepspassword master password (two beepsconfirm entry in confirm userprogramming mode) cancellation)“Beep Beep” “Beep Beep”WARNING: All the keypads are soldwith the default security code:“000000000”It is highly advised to customize the code!Made in China.GUARANTEEWarranty period: 12 months from the production date placed inside. In this period ifthe keypad has any malfunction due to defective component, it will be repaired orreplaced by the manufacturer. The warranty doesn't cover the plastic box.The assistance will be performed at the factory in Phoenix, AZ.1 2345Dial the master Press “6” Dial the sequence Press “#” Then press “6”password (two beepsof 9 couples of  to close  confirm entry innumbers with (two beeps confirmprogramming mode)correspondingcorrect programming)symbol(See Example 1)“Beep Beep” “Beep Beep”Security Code Setting/Dip-Switch SettingWARNING: All user codes will be deleted after this procedure.Master Password Reset1 2 3 4 5 6       Dial the factory Press “5” Press the serial # Press “5” Press the Press “5”master password from the keypad serial # again(two beeps(11111) confirm)“Beep Beep”“Beep Beep”Example 1 –  Dip-switches of a Tx already programmed on the receiver: +, 0, -, +, -, -, +, 0, +.STEP 1: Dial the “Master Password”STEP 2: Press “6”STEP 3: Enter Sequence: “1#”, “20”, “3*”, “4#”, “5*”, “6*”, “7#”, “80”, “9#”STEP 4: Press “#” then “6”TG6T433CKPD

Navigation menu