Renishaw plc RMP60Q RMP60 Radio Machine Probe User Manual Manual pt2
Renishaw plc RMP60 Radio Machine Probe Manual pt2
Contents
- 1. Manual pt 1
- 2. Manual pt2
Manual pt2
Fault finding 7.1 Symptom Probe fails to power up (no LEDs illuminated or fails to indicate current probe settings). Probe fails to switch on. Cause Action Exhausted batteries. Change batteries. Unsuitable batteries. Change batteries. Batteries inserted incorrectly. Check battery insertion. Batteries removed for too short a time and probe has not reset. Remove batteries for a minimum of 5 seconds. Exhausted batteries. Change batteries. Batteries inserted incorrectly. Check battery insertion. Probe out of range. Check position of RMI or RMI-Q, see operating envelope. No RMI or RMI-Q 'start/stop' signal (radio on mode only). Check RMI or RMI-Q for green start LED. Incorrect spin speed (spin switch on only). Check spin speed and duration. Malfunctioning shank switch (shank switch mode only). Check switch operation. Incorrect switch on method configured. Check configuration and alter as required. Incorrect multiple probe mode setting configured. Check configuration and alter as required. RMP60 in hibernation mode (radio on mode only). Ensure probe is in range and wait up to 30 seconds, then resend switch on signal. Check position of RMI or RMI-Q, see operating envelope. Draft copy 09/07/12 RMP60 installation guide Fault-finding Symptom Machine stops unexpectedly during a probing cycle. 7.2 Probe crashes. Cause Action Radio link failure/RMP60 out of range. Check interface/receiver and remove obstruction. RMI or RMI-Q receiver/machine fault. Refer to receiver/machine user’s guide. Exhausted batteries. Change batteries. Probe unable to find target surface. Check that part is correctly positioned and that stylus has not broken. Stylus not given sufficient time to settle from a rapid deceleration. Add a short dwell before the probing move (length of dwell will depend on stylus length and rate of deceleration). False probe trigger. Enable enhanced trigger filter. Selection error for RMI-Q. Review interface error indication and correct. Workpiece obstructing probe path. Review probing software. Probe length offset missing Review probing software. Draft copy 09/07/12 Poor probe repeatability and/or accuracy. RMP60 status LEDs do not correspond to RMI or RMI-Q status LEDs. Cause Action Debris on part or stylus. Clean part and stylus. Poor tool change repeatability. Redatum probe after each tool change. Loose probe mounting on shank or loose stylus. Check and tighten as appropriate. Calibration out of date and/or incorrect offsets. Review probing software. Calibration and probing speeds not the same. Review probing software. Calibration feature has moved. Correct position. Measurement occurs as stylus leaves surface. Review probing software. Measurement occurs within the machine’s acceleration and deceleration zone. Review probing software and probe filter settings. Probing speed too high or too slow. Perform simple repeatability trials at various speeds. Temperature variation causes machine and workpiece movement. Minimise temperature changes. Machine tool faulty. Perform health checks on machine tool. Radio link failure – RMP60 out of RMI or RMI-Q range. Check position of RMI or RMI-Q, see operating envelope. RMP60 has been enclosed/ shielded by metal. Change batteries. RMP60 and RMI or RMI-Q are not partnered. Partner RMP60 and RMI or RMI-Q. Draft copy 09/07/12 Fault-finding Symptom 7.3 RMP60 installation guide Fault-finding Symptom 7.4 RMI or RMI-Q error LED lit during probing cycle. Cause Action Probe not switched on or probe timed out. Change setting. Review turn off method. Probe out of range. Check position of RMI or RMI-Q see operating envelope. RMI or RMI-Q low battery LED lit. Low batteries. Change batteries soon. Reduced range. Local radio interference. Identify and remove. Probe fails to switch off. Incorrect switch off method configured. Check configuration and alter as required. No RMI or RMI-Q 'start/stop' signal (radio on mode only). Check RMI or RMI-Q for green start LED. Probe in timeout mode and placed in tool magazine and is being triggered by movement. Use shorter timeout setting or use different switch off mode. Malfunctioning shank switch (shank switch mode only). Check switch operation. Incorrect spin speed (spin switch on only). Check spin speed. Level start used for M code on/off when the probe is set to radio on/ timeout off. Change to a pulsed M code or change the probe to radio on/off. Probe was triggered when batteries were inserted. Do not touch the stylus or stylus mounting face during battery insertion. Probe goes into Trigger Logic™ configuration mode and cannot be reset. Draft copy 09/07/12 Parts list 8.1 Type Part number Description RMP60 A-5742-0001 RMP60 probe with batteries, tool kit and quick-start guide (factory set to radio on/radio off). RMP60M module A-5742-1003 RMP60M module with batteries, tool kit and quick-start guide (factory set to radio on/radio off). Battery P-BT03-0005 AA battery – alkaline type – supplied as standard with probe (two required). Battery P-BT03-0008 AA battery – Lithium Thionyl Chloride (two required). Stylus A-5000-3709 PS3-1C ceramic stylus 50 mm long with Ø6 mm ball. Weak link kit A-2085-0068 Weak link (Part no. M-2085-0069 x 2) and 5 mm AF spanner. Tool kit A-4038-0304 Probe tool kit comprising Ø1.98 mm stylus tool, 2.0 mm AF hexagon key, 2.5 mm AF hexagon key (x 2), 4.0 mm AF hexagon key (x 2) and shank grub screw (x 2). Battery cassette A-4038-0300 RMP60 battery cassette assembly. Cassette seal A-4038-0301 Battery cassette housing seal. Diaphragm kit A-5312-0302 RMP60 diaphragm kit. Bobbin kit A-4038-0303 Bobbin for shank switch (supplied with shank). RMI A-4113-0050 RMI – side exit – with 15 m (49.2 ft) cable, tool kit and user's guide. RMI-Q A-5687-0050 RMI-Q – side exit – with 15 m (49.2 ft) cable, tool kit and user's guide. Mounting bracket A-2033-0830 Mounting bracket with fixing screws, washers and nuts. Styli tool M-5000-3707 Tool for tightening/releasing styli. LP2 A-2063-6098 LP2 probe complete with two C spanners and TK1 tool kit. Extension L100 A-4038-1010 RMP60M extension - 100 mm long. Extension L150 A-4038-1027 RMP60M extension - 150 mm long. Extension L200 A-4038-1028 RMP60M extension - 200 mm long. RMP60/OMP60M probe module assembly A-4038-1002 RMP60M probe module assembly. Draft copy 09/07/12 Parts list RMP60 installation guide 8.2 Type Part number Description RMP60M/LP2 adaptor A-4038-0212 RMP60M LP2 adaptor assembly. LPE1 A-2063-7001 LPE1 extension bar - 50 mm long. LPE2 A-2063-7002 LPE1 extension bar - 100 mm long. LPE3 A-2063-7003 LPE1 extension bar - 150 mm long. MA4 A-2063-7600 MA4 90° adaptor assembly. Publications. These can be downloaded from our web site at www.renishaw.com RMP60 A-5742-8500 Quick-start guide: for rapid set-up of the RMP60 probe, includes CD with installation guides. Styli H-1000-3200 Technical specification: Styli and accessories. Software features H-2000-2289 Data sheet: Probe software for machine tools – illustrated features. Software list H-2000-2298 Data sheet: Probe software for machine tools – list of programs. Taper shanks H-2000-2011 Data sheet: Taper shanks for machine tool probes. RMI A-4113-8550 Quick-start guide: RMI – radio machine interface. RMI-Q A-5687-8500 Quick-start guide: RMI-Q – radio machine interface. Draft copy 09/07/12 Draft copy 09/07/12 Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com www.renishaw.com For worldwide contact details, please visit our main website at www.renishaw.com/contact © 2012 Renishaw plc *H-5742-8504-01* Draft copy 09/07/12 Issued July 2012 Part no. H-5742-8504-01-A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 8 Creator : pdfsam-console (Ver. 2.4.0e) Producer : iText 2.1.7 by 1T3XT Modify Date : 2012:08:16 16:43:07+01:00 Create Date : 2012:08:16 16:43:07+01:00EXIF Metadata provided by EXIF.tools