Rentokil Initial 1927 plc GSD-500349 LongReach Radio Module User Manual Title page image

Rentokil Initial 1927 plc LongReach Radio Module Title page image

Users Manual - MMT

Download: Rentokil Initial 1927 plc GSD-500349 LongReach Radio Module User Manual Title page  image
Mirror Download [FCC.gov]Rentokil Initial 1927 plc GSD-500349 LongReach Radio Module User Manual Title page  image
Document ID3834737
Application IDJ7aZawxRonnkV0gzD/KJRg==
Document DescriptionUsers Manual - MMT
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize110.66kB (1383242 bits)
Date Submitted2018-05-01 00:00:00
Date Available2018-05-01 00:00:00
Creation Date2018-04-24 16:17:32
Producing SoftwareMicrosoft® PowerPoint® 2013
Document Lastmod2018-04-24 16:17:32
Document TitleTitle page [image]
Document CreatorMicrosoft® PowerPoint® 2013
Document Author: Catherine Allport

Multi Mouse Trap Connect
(MMT) User Guide
Adam O’Callaghan/JMc
16-04-18 – GSD-100694 Version 1.0
MMT - Overview
•
Retrofittable to TinCat models from Victor and JT Eaton.
•
Retrofittable to Little Pete models from JT Eaton
•
Battery Powered
•
Reports activations directly to PestNet Online
•
Based on RI Connect LongReach 868/915MHz Technology
Introduction to the PestConnect
System
Control Panel
MMT Connect
Units
MMT Technical Details
Battery Supply
2 x AA Cell Alkaline Batteries
Dimensions
112mm x 38mm x 60mm
Material
20% Glass Filled PC
Weight
173g
Operating Temperature
-20 to +50 Celcius
Mounting
JT Eaton & Victor TinCat’s
JT Eaton Little Pete
Standards/Certifications
FCC
IP Rating
IP67
Product Exploded View
MMT Sensor – Key Hardware Features 1 / 2
Infra Red light Sensors scan
inside the trap, monitoring for
rodent activity.
2 x Hidden until lit LED’s show
the technician the status of the trap
MMT Sensor – Key Hardware Features 2 / 2
Battery compartment – housing 2 x AA Alkaline Batteries
In box components
Live Catch Connect Sensor
Rubber Bungs (x2)
Anti reflection
label
NB: For each box of 10 x MMT sensors 1x Pest Key and 2x
allen keys will be provided
Fixing Bolts (x2)
Trap Fixing Bracket
Install Step 1 – Remove Front Cover using
Pest Key
Step 1
Step 2
Step 3
Install Step 3 – Align Infra Red Sensors
Lenses to the openings in the trap
Victor Tin Cat
JT Eaton Tin Cat
Infra red sensor lenses align with the traps on the RHS as shown above for Tin Cat.
NB: For Little Pete there is only one alignment option.
10
Install Step 4 – Bolt Sensor to trap
Victor Tin Cat
JT Eaton Tin Cat
Position LED Lenses to Trap Holes as shown above.
Take the Trap Fixing Bracket and
Orientate as shown above.
11
Place the Trap Fixing Bracket over the LED Lenses
and hold together for bolting (see next page).
Install Step 4 – Bolt Sensor to trap
First Bolt
Second Bolt
Bolts Fitted
Tighten bolts using allen key provided or any suitable 8mm allen key.
Please note that the above bolt configuration is for Victor Tin Cat.
Use the other set of holes for bolting the JT Eaton Tin Cat.
Tighten bolts & ensure sensor is securely fitted to
the trap. The Sensor should be parallel to trap as
shown left.
12
Install Step 5 – Fit Rubber Bungs
Fit the two supplied rubber bungs to
the sensor using the allen key
supplied. This is required to close and
seal the two unused holes to prevent
water ingress (mandatory).
Please note that this bolt configuration
is for Victor Tin Cat.
Use the other set of holes for rubber
bungs sealing the JT Eaton Tin Cat.
Push the bung firmly down to fully
insert as shown. The top of the
rubber bung must be level or sub
flush to the top surface in both
positions.
13
Install Step 6 – Fit Label to Trap
Fit the supplied black label inside the
Victor/JT Eaton at the opposite end of
the trap from the sensor (mandatory).
Peel back the release liner to reveal
the adhesive and adhere accordingly.
Please note that this configuration
(Picture left) is Victor Tin Cat.
Identical required for JT Eaton Tin
Cat.
Ensure that the are two holes open.
14
Install Step 7 – Fit Rubber Sealing Boot.
Orientate and Push Fit the supplied
Black Rubber Sealing Boot to the
Sensor in position shown left
(mandatory).
15
Install Step 8 – Install Batteries
Note 1: Only use suitable AA Alkaline Batteries
Note 2: The trap lid MUST BE CLOSED during the battery installation to avoid
false triggers during the final setup stage, pictures for reference only.
16
Install Step 9 – Replace the Cover
Right hand side first, ensuring clip is engaged
SNAP!
17
Fitment to Little Pete
To fit the MMT sensor to a Little Pete trap.
Follow all of the previous steps (identical hole configuration to JT Eaton Tin Cat).
Align label with top edge of
entrance housing
Ensure label is flat and smooth
when finished.
18
Connect Setup Sequence (1/2)
(Read all steps through before starting)
Upon initial Power Up the two LED’S
go into a Red Level Crossing Effect.
19
Open Trap and break the infra red
sensor beams.
Connect Setup Sequence (2/2)
(Read all steps through before starting)
Close Lid
LED’s now flash Red/Blue until
connected to the control panel at
which point 5 blue flashes will
indicate a successful connection.
Connection can take upto 2minutes
depending on the number of
repeaters installed, wait until the “5
blue flashes” are seen
Trap is now connected and ready to be placed in situ and left.
20
Technician Service Mode (1/2)
Place pest key over the magnet target area for a few seconds
and then remove and watch for blue LEDs (Level Crossing
Effect).
21
Technician Service Mode (2/2)
2 x Blue LED’s flash every 3
seconds indicating it is now ok to
open the lid of the trap to service.
Servicing can commence.
To rearm the trap swipe the magnet again and repeat the ‘Connect Setup Sequence’
by testing the IR’s and confirming the system has reconnected to the Control Panel.
22
LED’s & Troubleshooting
LED
23
Sensor State
Detail
Action
Single Solid
Red
During Power on
Battery Level Low
Replace Battery
Red Level
Crossing LED
During Power on
Trap awaiting sensor test
Open Lid and break the infra red beams with hand
Red & Blue
Flashing LED
Setup
Attempting connection to Control
Panel
Please wait
5 x Blue LED
Flashes
Setup /
Connection to
Control Panel
Sensor has successfully connected to
the Control Panel
No action required
5 x Red LED
Flashes
Setup /
Connection to
Control Panel
Sensor has been unable to connect
to the Control Panel.
Reduce the distance from sensor to Control Panel or install
a repeater.
Single flashing
blue LED
Setup
One set of Infra Red sensors has
been tested, awaiting test of other
set.
Replace hand in trap and swipe left to right, place hand
closer to sensor. Replace sensor if fault persists
Solid Green
LED
Setup
Infra Red Sensors have not been
triggered within 30 seconds
Begin setup again. Replace sensor if unable to clear fault.
Rapid Flashing
Green LED
Setup
One set of IR’s has passed, one set
has failed and 30 seconds has
elapsed
Begin setup again. Replace sensor if unable to clear fault
2 x Solid Blue
LED’s
Mag swipe
Sensor entering service mode
Wait 3 seconds for the trap to enter service mode
Blue Level
Crossing LED
Service Mode
Trap is in service mode, it is safe to
open the trap without sending false
trigger alerts to the Control Panel
Service trap
Solid RED LED
– Flashing
Blue LED
Entering Service
Mode
Low Battery has been detected
Replace battery
Thank you

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 24
Language                        : en-GB
Tagged PDF                      : Yes
Title                           : Title page [image]
Author                          : Catherine Allport
Create Date                     : 2018:04:24 16:17:32+01:00
Modify Date                     : 2018:04:24 16:17:32+01:00
Producer                        : Microsoft® PowerPoint® 2013
Creator                         : Microsoft® PowerPoint® 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AK3PGSD-500349

Navigation menu