Resolution RE153 Outdoor Motion Detector, 319.5MHz User Manual RE153 GE Compat Outdoor PIR Instructions
Resolution Products, Inc. Outdoor Motion Detector, 319.5MHz RE153 GE Compat Outdoor PIR Instructions
User Manual
Specifications Mounting hardware: Mounting height: Replacement Battery: Temperature Range: White Light Immunity Housing dimensions: Wireless Security Solutions RE153 GE-Compatible PIR Motion, Outdoor Features • DFIR™ Dual Frequency IR Detection. o Wind-blown object and air current rejection o White light and lightning rejection o Split View™ look-down element • 44 foot range and 90 degree field of view (45 degrees to each side) • Mountable on Flat-wall, 45 degree corner, or swivel/gimbal (sold separately). • Cover tamper. • Strong, reliable RF signal. • 6-8 year battery life on CR123A battery. • Low Battery indication. Key Instructions • Mount at 7.5 foot height. • Motion Sensitivity: Jumper on BOTH PINS for Normal sensitivity Jumper on ONLY 1 PIN for High sensitivity. • External contact activation (enabling): Insert battery while holding Tamper switch. DL ID# for Ext Contact is Motion DL ID# + 1. • LED Walk Test: Press Tamper for 3 minute test: LED lights when motion sensed Wireless transmissions sent for each detection, so walk test can be used for panel operation test as well Motion stops (locks out) sensing for 20 seconds after LED blinks • Enrolling: Motion: Press tamper switch for enrollment in GE panel. External Contact: 1. Have external zone in ALARM state. 2. Insert battery while holding Tamper switch. 3. Close and open the external zone. This tells the GE panel to start paying attention to the external zone. • If wire is routed through housing for external contact, make sure hole is sealed. # 4 or #6 screws 7.5 ft with normal lens CR123A 1550mAH -20F to 120F 25,000 lux 6.7x3.0x2.4 inches 45 ft Specifications subject to change without notice. 7.5 ft 45 ft 18 ft 27 ft 36 ft 45 ft 45 ft Internal Picture Walk Test LED External Contacts Battery Motion Sensor Tamper & Walk Test Switch unused jumper pins DO NOT connect Sensitivity Jumper Operation • Motion sends wireless transmission after 2 or 3 (select via jumper) pulses. • Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after sending an alarm transmission. This is to conserve battery life. • Tamper, when cover is opened (only Motion reports tamper, not Ext Contact). • Supervisories, every hour (including Ext Contact, if activated). RE153_GE-Compat_Outdoor_PIR_Instructions.doc Page 1 of 3 RE153_GE-Compat_Outdoor_PIR_Instructions.doc 17-Jul-12 www.ResolutionProducts.com Page 2 of 3 17-Jul-12 www.ResolutionProducts.com Notices “GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell International Inc., and Tyco Safety Products Canada LTD, respectively. Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems. However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control panel installation instructions, at installation. Warranty Resolution Products, Inc. will replace products that are defective in their first year. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment. FCC ID: U5X-RE153 IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. IC: 8310A-RE153 RE153_GE-Compat_Outdoor_PIR_Instructions.doc Page 3 of 3 17-Jul-12 www.ResolutionProducts.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : f24ce19e-d28a-11e1-0000-92abb9614c5d Producer : GPL Ghostscript 8.64 Keywords : () Modify Date : 2012:07:17 11:49:11-05:00 Create Date : 2012:07:17 11:49:11-05:00 Creator Tool : \376\377\000P\000D\000F\000C\000r\000e\000a\000t\000o\000r\000 \000V\000e\000r\000s\000i\000o\000n\000 \0000\000.\0009\000.\0008 Document ID : f24ce19e-d28a-11e1-0000-92abb9614c5d Format : application/pdf Title : \376\377\000R\000E\0001\0005\0003\000_\000G\000E\000-\000C\000o\000m\000p\000a\000t\000_\000O\000u\000t\000d\000o\000o\000r\000_\000P\000I\000R\000_\000I\000n\000s\000t\000r\000u\000c\000t\000i\000o\000n\000s Creator : \376\377\000b\000s\000e\000e\000m\000a\000n\000n Description : () Author : bseemann Subject :EXIF Metadata provided by EXIF.tools